Reports 1-1 of 1 Clear search Modify search
AdV-TCS (Ring Heater)
nardecchia, gherardini, nocera - 16:33 Tuesday 16 June 2026 (69238) Print this report
NE RH accidentally switched off and restored

During the NCal activities yesterday, the NE RH was accidentally switched off (see Fig. 1).

Benoit reported the presence of a loose cable in the RH electronics chain. Therefore, today Flavio inspected the system to investigate the issue and verify the cable connections.
Following the inspection, the RH was switched back on at 14:23 UTC with the voltage set to 16.6 V.

Images attached to this report
Comments to this report:
nocera - 16:47 Tuesday 16 June 2026 (69240) Print this report

R. Cavalieri, F.Nocera

we went to the NE and inspected the Ring Heater Power Supply and its cabling.

There is nothing special to say: it is a commercial device with a regular, *non-locking* power input connector and it uses a commercial 3-wire AC power supply cord (CEE 7/7 Plug to IEC 60320 C13 Power Cord, if you are interested in this sort of details).

If left alone, it does its job nicely.

Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×