AdV-TCS (Point Absorbers Mitigation)
corubolo, nardecchia, lumaca, pasqualetti, gherardini, francescon - 11:13 Wednesday 10 June 2026 (69208) Print this report
WI PAM actuator position reference and movement, plus viewport external inspection

This morning (09:00 - 10:00 LT), we went to the WI base tower to take reference pictures and measurements of the PAM actuator position (see Fig. 1).

Afterwards, we contacted the vacuum team to understand how much clearance is needed for the future replacement of the viewport. We agreed that moving the PAM actuator to a parking position on the base tower would provide sufficient clearance for the planned work. (see Fig. 2).

Finally, we took some pictures of the viewport to be replaced, as seen from the outside (Fig. 3). From the outside, the smaller viewport does not show the same signs of degradation as the viewport to be replaced. In particular, no sparkling/glittering features are visible, which would suggest dust or coating flaking, as observed on the damaged viewpor t (69192).

Images attached to this report
Comments to this report:
Vacuum, Nardecchia - 18:18 Thursday 11 June 2026 (69217) Print this report
here is a picture of the smaller ZnSe viewport taken from the interior: it seems in good condition, with no visible coating delamination.