Reports 1-1 of 1 Clear search Modify search
AdV-TCS (CO2 laser projector)
corubolo - 18:09 Friday 10 April 2026 (68982) Print this report
Power and centering checks

Since the ITF unlocks at the very beginning of CARM_NULL_1F (68979), the powers and the centering of the CO2 actuators were checked to assess any variations.

Between 13:35 and 14:00 UTC, different images were acquired using the thermal camera. No displacement was detected, based on the actuators’ conditions on 10 March 2026 (see Figure 1).

From 14:00 to 14:15 UTC, the power of the CO2 actuators was verified. All measured values are consistent with the nominal values, as reported in the following table.

 

   

CH [W]

DAS IN [W]

DAS OUT [W]

WI

on the ITF

0.070

0.160

1.536

on the pickoff

0.430

(0.428 nominal)

0.026

(0.025 nominal)

0.25

(0.25 nominal)

NI

on the ITF

0.100

0.467

3.532

on the pickoff

0.611

(0.613 nominal)

0.076

(0.078 nominal)

0.575

(0.580 nominal)

Images attached to this report
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×