Since the ITF unlocks at the very beginning of CARM_NULL_1F (68979), the powers and the centering of the CO2 actuators were checked to assess any variations.
Between 13:35 and 14:00 UTC, different images were acquired using the thermal camera. No displacement was detected, based on the actuators’ conditions on 10 March 2026 (see Figure 1).
From 14:00 to 14:15 UTC, the power of the CO2 actuators was verified. All measured values are consistent with the nominal values, as reported in the following table.
| CH [W] | DAS IN [W] | DAS OUT [W] | ||
|---|---|---|---|---|
| WI | on the ITF | 0.070 | 0.160 | 1.536 |
| on the pickoff | 0.430 (0.428 nominal) | 0.026 (0.025 nominal) | 0.25 (0.25 nominal) | |
| NI | on the ITF | 0.100 | 0.467 | 3.532 |
| on the pickoff | 0.611 (0.613 nominal) | 0.076 (0.078 nominal) | 0.575 (0.580 nominal) |