Reports 1-1 of 1 Clear search Modify search
Injection system (General activities)
derossi, lagabbe, spinicelli, gosselin - 12:32 Friday 10 April 2026 (68978) Print this report
checks on the IMC loop

This morning, since the ITF unlocks once the SSFS is engaged, we checked the longitudinal and angular working points of the IMC loop.

  • For the longitudinal we found that the offset which minimize the coupling of the fmoderr line on the pmc is -0.07 V (instead of 0.03 V, so no much difference), see attached plot.
  • For the angular wp  (offsets on the galvos used to center the beam on the RF quadrants), we found that the did not change substantially:

ACL_CONST_CH FF_H_offset    "V/V"    1   LOOP_FREQ   -0.25 #-0.28
ACL_CONST_CH FF_V_offset    "V/V"    1    LOOP_FREQ   +0.5 #+0.58  
ACL_CONST_CH NF_H_offset    "V/V"    1   LOOP_FREQ   0.0 #-0.04  
ACL_CONST_CH NF_V_offset    "V/V"    1    LOOP_FREQ   -0.19 #-0.19 

  • IMC UGF seems to be ok (around 101 kHz with 25deg phase margin)

 