casanueva, derossi, gouaty, masserot, mours, rolland - 18:40 Monday 23 March 2026 (68929) Print this report
Acl update with v1r39p17

The Acl's servers running on the following rtpcs have been restarted with the Acl release v1r39p17

  • ASL rtpcs : rtpc22 (trend plot), rtpc24(trend plot)and rtpc10 (trend plot)
    • Operations performed between 2026-03-23-06h22m00-UTC and  2026-03-23-06h39m45-UTC
    • the ITF has been unlocked at 2026-03-23-06h30m21-UTC  to performed the update of the Acl's rtpc server.
    • After these operations the ITF has been successfully locked upto LOW_NOISE_3_ALIGNED  at  2026-03-23-07h10m46-UTC
    • ITF unlocked  2026-03-23-07h23m08-UTC to continue the Acl deployment 
  • SPRB and LNFS rtpc: rtpc6 (trend plot)
    • LC and SBE loops openned 
    • Operations performed between 2026-03-23-07h25m14-UTC and 2026-03-23-07h33m42-UTC
    • LC and SBE loops successfully closed 
    • After these operations the ITF has been successfully locked upto CARM_NULL_1F  at  2026-03-23-07h45m21-UTC
    • ITF unlocked  2026-03-23-07h47m16-UTC to continue the Acl deployment
  • SWEB  rtpc: rtpc9 (trend plot)
    • LC, SBE, PCAL and NCAL loops openned
    • Operations performed between 2026-03-23-07h47m55-UTC and 2026-03-23-07h59m27-UTC
    • LC, SBE, PCAL and NCAL loops successfully closed
    • After these operations the ITF has been successfully locked upto LOW_NOISE_3_ALIGNED at  2026-03-23-08h30m48-UTC
    •  ITF unlocked  2026-03-23-08h31m17-UTC to continue the Acl deployment
  • SIB2 rtpc: rtpc18 (trend plot)
    • LC and SBE loops openned 
    • Operations performed between 2026-03-23-08h32m26-UTC and 2026-03-23-08h34m43-UTC
    • LC and SBE loops successfully closed
    • After these operations the ITF has been successfully locked upto CARM_NULL_1F at  2026-03-23-08h48m12-UTC
    •  ITF unlocked  2026-03-23-08h48m58-UTC to continue the Acl deployment
  • SDB1, SDB2  rtpcs: rtpc1(trend plot) and rtpc13 (trend plot)
    • LC(SDB1,SDB2), SBE(SDB2) and OMC  loops openned 
    • Operations performed between 2026-03-23-08h50m27-UTC and 2026-03-23-09h00m26-UTC 
    • LC(SDB1,SDB2), SBE(SDB2) and OMC  loops successfully closed
    • After these operations the ITF has been successfully locked upto CARM_NULL_1F at 2026-03-23-09h17m-UTC , and to LOW_NOISE_3_ALIGNED at  2026-03-23-09h42m24-UTC

Acl 's upgrade  second block complete 

Images attached to this report
Comments to this report:
gosselin, masserot, vardaro - 17:14 Wednesday 25 March 2026 (68939) Print this report

We completed the Acl v1r39p17 version deployment 

  • SQZ rtpcs: rtpc2 (trend plot), rtpc3 (trend plot) and rtpc23  (trend plot)
    • All the LC and SBE loops were already openned by Marco between the  2026-03-23-23h58m42-UTC and 2026-03-23-23h59m27-UTC
    • Operations performed between 2026-03-24-07h11m30-UTC and 2026-03-24-07h22m09-UTC
  • INJ rtpc: rtpc19 (trend plot)
    • The EIB bench has been blocked by Matthieu around 7h10-UTC
    • Operations performed between 2026-03-24-07h22m46-UTC and 2026-03-24-07h26m43-UTC

The Acl update on the SUSP rtpc(rtpc4) has been postponed after the computing shutdown, in agreement with the TCS and commissioning coordinators

 

Images attached to this comment