Reports 1-1 of 1 Clear search Modify search
DAQ (DAQ)
cortese, kraja, berni - 10:27 Tuesday 03 March 2026 (68798) Print this report
SDB2 minitower switch down

We have been warned that after the reboot due to last saturday blackout the switch mtswitch-sdb is not reachable anymore.

We checked that on the network side in DAQ room all is working.

After agreement with Pacaud we swapped the transceivers on the general infrastructure switch between the sdb2 and sib2 ports and the link down remains on the sdb2 port.

The conclusion is that the failure is on the side of the LAPP mtswitch inside the SDB2 minitower

Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×