Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Data collection)
masserot - 9:28 Tuesday 30 September 2025 (67823) Print this report
DAQ - maintenance activities

As there is still some missing channels collected by the SUSP_Fb server running on the rtpc4 host  . The TIMING_moni server has been restarted with a reduced  DAQ channels set .

Operation performed at 2025-09-30-06h25m07-UTC

The attached plot shows the trend of some rtpc4 channels before and after the operation: the output data flow (bond0_tx) has been reduced by 0.5MB/s (from 21MB/s to 20.5MB/s)

The next trial to perform will be  to try to acquire the Sc_NI and Sc_WI channels on the ISC_rtpc, as it s done for the others Sc_{PR,BS,SR,NE,WE}, instead of the SUSP_rtpc today

Images attached to this report
Comments to this report:
masserot - 9:47 Tuesday 07 October 2025 (67875) Print this report

As trial to reduce the SUSP_Fb input data flow,  this morning the data related to the TCS_ADC_Moni1 ADC7674 are now sent ot the ISC_rtpc instead of the SUSP_rtpc

  • operation performed at 2025-10-07-07h09m53-UTC

 