Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Data Acquisition and Global Control)
masserot - 18:57 Tuesday 24 June 2025 (67118) Print this report
Comment to DAQ - Monitoring of the fibers use to exchange between DAQ room and Sc_{N,W}E Pisa DSPs (67111)

As a workaround,  the LSC_Acl minimun elapsed_time has been set to 29 us instead of 25 us previously in order to avoid the Tolm packets reception close to the starting time of a DSP cyle (25 us)  for the NE and WE DSPs:

  • Operation performed at 2025-06-24-16h20m30-UTC

As consequence the ASC_pre minimun elapsed_time has been increased by 5us too to reach 25us

  • Operation performed at 2025-06-24-16h57m03-UTC
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×