mwas, bersanetti - 20:27 Thursday 15 May 2025 (66799) Print this report
WE glitches

There are many unlocks caused by glitches at west end. These are visible in many of the WE channel. The glitches on Sc_WE_MAR_TY look like data errors, dropping to zero. And they are very frequent, but not always causing unlocks. Some of them are associated with glitches on coil, WE_F0_COIL_H1, and these were present in the three unlocks I have looked at, but not present for one MAR TY glitch that did not cause an unlock.

Figure 1 and 2 show examples of unlocks

Figure 3 shows that The H3 coil is close to saturation at 9V. The H1 is also flagged but less critical at 5V.

My conclusion is that there is some data communication error showing up as glitches, and some of them are kicking the suspension. The high horizontal correction on F0 are unhealthy, it is less likely they are the cause of the problem, but at least this should be simple to solve acting on the corresponding motor.

Figure 4 shows how the situation has detoriarated over the past 4 days with glitches increasing from zero, to many times per minute for MAR TY. The coils have a daily oscillation, the glitches might be associated with H3, whenever the correction becomes very negative. Could be that the correction draws too much power and causes insufficient power to the digital system doing the communication and computations.