Related to the EDB server , the code for the EDB_OMC1 control has been added successfuly . It remains to test it
Cabling informations
- EDB_DBOX_DetLab - DaqBox SN52
- mezzanine 0: DAC1955-SN46
- ch02 - OMC1_PZT_dac : PZT driving signal
- ch03 - OMC1_Peltier_dac : Peltier driving signal
- mezzanine 2: ADC2378-SN06
- ch02 - EDB_OMC1_PZT_out : PZT command readout
- ch03 - EDB_OMC1_Peltier_out : Peltier command readout
- ch04 - EDB_OMC1_Temp_out : OMC1 Temperature sensor readout
- mezzanie 3 - SERVICE-SN10
- ch00-01 - EDB_B1t _PD1 : B1t_PD1 Audio/DC readout
- ch04-05 - EDB_B1s_PD1 : B1s_PD1 Audio/DC readout
- mezzanine 0: DAC1955-SN46
- EDB_DBOX_DetLab2 - DaqBox SN113
- mezzanine 3 - DEMOD-SN43
- ch00 - EDB_B1t_PD : EBD_B1t RF readout
- ch01 - EDB_B1s_PD : EDB_B1s RFÂ readout
- mezzanine 3 - DEMOD-SN43