Storage: ENV_*_ALS_* channels
The servers Stol01RawFbm_10 and Stol02RawFbm_10 have been restarted to store whatever ITF_LOCK_index values the ENV_*_ALS_* channels. These channels were previously stored when the ITF_LOKC_INDEX was less than 90.
Operations performed between 2025-01-07-07h37m40-UTC and 2025-01-07-07h38m22-UTC .(see this picture)
EDB QD1 and QD2 Quadrants at 50MHz
On request of the commissioning coordinators, the EDB_QD1 and EQB_QD2 quadrants are now demodulated at 50MHz
- EDB_dbox_rack server: its configuration has been updated by adding the corresponding lines to the 50 MHz demodulation
- EDB_QD_AA server:
- its configuration has been updated to build the 50MHz demodulated signals with the possibilty to apply a demodulation phase noise reduction based on the 112MHz phase extracted on each quadrant sector.
- the mains output channels are
- V1:EDB_B1s_QD{1,2}_50MHz_{X,Y,SUM}_{I,Q}
- V1:EDB_B1s_QD{1,2}_50MHz_phase_noise_enbl
- It VPM inteface has been upgraded with new menus
- to Enable / Disable the phase noise mitigation
- to set the different phi0 phase channels