Upon arrival I found ITF in Science Mode (LN3_SQZ).
At ~ 08:50 UTC the vertical position loop of SWEB opened. I set Adjusting Mode and closed it but it opened again after few minutes. I tried to act on MotSwitch but it was not working. I contacted SBE OnCall but the issue was related to the old version of MotSwitch VPM config file. I restarted the MotSwitch process and act on MotSwitch Olwin tool to recover the vertical position of the bench. I made a check for all SBE MotSwitch processes are running with the v4r4 version.
Science Mode set again at 09:45 UTC.
No DMS Events Monitor to report
Oncall eventsDET
(16-04-2024 19:30 - 23:15) From remote
Status: On-going
Description: unlock at DC_READOUT step
SBE
(17-04-2024 10:00 - 17-04-2024 10:30) Operator on site with expert from remote
Status: Ended
Description: SWEB vertical loop open.
Problem fixed thanks to Carbognani who investigated on MotSwitch VPM config file process.