Reports 1-1 of 1 Clear search Modify search
On-call intervention (General)
Oncall-system - 10:01 Sunday 21 January 2024 (63035) Print this report
On-call intervention

The following report has been submitted to the On-call interface.

On-call events -> Injection System

Title: INJ system failure

Author(s): melo

Called at: 08:25, 21-01-2024, by: Menzione
Remote intervention: Started: 08:25, 21-01-2024; Ended: 09:30, 21-01-2024
On-site intervention: Started: ; Ended:
Status: Resolved
Operator when issue resolved: Menzione

Details:

This morning I was called by the operator because the INJ system went off again.

I followed the exact same procedure from yesterday, i.e.,

- Open all the loops (BPC, AA, MC, RFC)

Applied a hysteresis on the BPC DSP card and unloaded the integrators;

- Bring BPC to the correct working point acting on the picomotors on EIB;

- Verify Automatic Alignment and bring back MC_F0_Z to the right position (today it was off only by 100 um);

- Verify FmodErr and relock all the loops.

At the end of the intervention INJ was back to golden state on the metraton node.

Deeper investigation is needed to understand what is causing these bad INJ unlocks.

 

 

* Note that any files attached to this report are available in the On-call interface.

Comments to this report:
derossi, gosselin, melo - 11:00 Monday 22 January 2024 (63048) Print this report

The unlock of the injection seens ti be due to a failure of the DSP, both the BPC and ML thermal corrections went to 0 (see plot).

Images attached to this comment
Boschi, Piendibene - 17:22 Tuesday 23 January 2024 (63067) Print this report

Boot image version of BPC DSP boards has been updated to the same version currently used on Sc_NI crate (see entry #62523).