Reports 1-1 of 1 Clear search Modify search
Injection system (EIB-SAS)
bertolini, bulten, chiummo, gherardini - 18:36 Thursday 29 September 2022 (57247) Print this report
Comment to INJ recovery (57211)
This afternoon we continued investigating the cause of the excess noise on the EIB vertical LVDTs. After Antonino has blocked the beam, Fabio disconnected and reconnected all 3 LVDT/voice coil pairs from the signal conditioning board in the EE room; surprisingly, it turned out that the excess noise has disappeared right before
starting the test (that therefore was not adding any new information). The change in the noise level clearly happened when an oscillation of the control loop was triggered, likely, by the work of Antonino in the laser lab at 14:33:05 UTC. The oscillation stopped when opening the position loop at 14:33:35 UTC (see Plot1).
Plot 2 shows the difference in the LVDTs raw noise level before and after the oscillation. Plot3 shows the error signal of the EIB control after the lucky intervention, with normal operating conditions recovered. The behaviour of the EIB is clearly not reliable and further investigation is needed in the coming days.
Images attached to this comment
Search Help
×