Reports 1-1 of 1 Clear search Modify search
AdV-TCS (Ring Heater)
casanueva, capocasa, chiummo, gouaty, menzione, nardecchia, pinto, trozzo - 23:40 Friday 13 May 2022 (55847) Print this report
Comment to PR RH switching ON (55846)

The two scans of the arms offer a first rough evaluation of the mismatch before switching on the PR RH and when the temperature was close to the steady state.

Plot 1 is an overview of the first scan (RH OFF): mismatch roughly 1.5% North Arm and 1% West Arm

Plot 2 is the second scan of the arms (RH ON, 21:12 UTC): mismatch roughly 3% North Arm and 1.8% West Arm

The compensation via meniscus lens on SIB1 has not been performed since it is preferable to wait for the transient to be fully completed.

Images attached to this comment