Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Data collection)
masserot - 23:04 Wednesday 12 January 2022 (54464) Print this report
DAQ events : olserver52 frozen or network troubles

Below the report of 3 same kind  of events where all the data are lost during 10-20 seconds:

For each event :

  • All the TolmFrameBullder servers are unable to sent theirs frames to the FbmFE server running on the olserver52 host
  • The Imaging servers have some difficulties to sent theirs frames to the FbmMain server running on the olserver52 host
  • the SlowFrameBuilder servers running on the olserver52 host seems stuck during 10 or 20s even if they are running on different CPUs

It's difficult to decouple  if the trouble become from the olserver52 host or the IP network  . Investigation inprogress

Images attached to this report
Non-image files attached to this report
Comments to this report:
masserot - 13:14 Thursday 13 January 2022 (54473) Print this report

The same kind of event occured today at 2022-01-13-09h35-UTC .

  • Fbs servers report:
    • FbsAlp::2022-01-13-09h35m56-UTC>WARNING-Main> local - gps 1326101774-007988000, prev 1326101760-002565000(000000000) - frDt 1, dt 14.008 - nb 14 - tmo 0.002784
    • FbsDet: 2022-01-13-09h35m56-UTC>WARNING-Main> local - gps 1326101774-391418000, prev 1326101760-001919000(000000000) - frDt 1, dt 14.3914 - nb 14 - tmo 0.004451
    • FbsISC: 2022-01-13-09h35m56-UTC>WARNING-Main> local - gps 1326101774-380448000, prev 1326101757-001676000(000000000) - frDt 1, dt 17.3804 - nb 17 - tmo 0.004783
    • FbsMoni: 2022-01-13-09h35m56-UTC>WARNING-Main> local - gps 1326101774-390485000, prev 1326101762-003021000(000000000) - frDt 1, dt 12.3905 - nb 12 - tmo 0.002747
    • FbsStorage: 2022-01-13-09h35m56-UTC>WARNING-Main> local - gps 1326101774-390459000, prev 1326101760-004777000(000000000) - frDt 1, dt 14.3905 - nb 14 - tmo 0.004476
    • FbsSup 2022-01-13-09h35m56-UTC>WARNING-Main> local - gps 1326101774-090746000, prev 1326101762-001249000(000000000) - frDt 1, dt 12.0907 - nb 12 - tmo 0.004462
  • All the TolmFrameBuilder severs and the  Imaging servers complains that they can sent theirs frames