Comment to Fast Unlock Investigatio - Increase of the ML pumping current (50535)

The IMC remained locked over the whole weekend.
It seems that, somehow, increasing the current of the ML pumping diodes, reduced the amplitude of the glitches on EOM_CORR (see plot 1 and 2). 
During the weekend the correction did not reach the +- 1V that makes the IMC unlock.

The only unlock was on the 25/01 at 06:12 UTC. It does not have the shape of the usual fast unlock. The correction of the ML_PZT starts to drift about 1 s before the unlock (see plot 3). This drift is not explain yet.