Reports 1-1 of 1 Clear search Modify search
Detector Characterisation (Data monitoring)
robinet - 11:20 Thursday 19 September 2019 (46963) Print this report
Threshold update for Omicron online vetoes

I updated the threshold files to generate Omicron online vetoes, using a recent UPV run over one week of data:

  • The threshold of V1:DAQ_FMOD_56MHz_phi-injalign has been adjusted
  • A veto based on V1:LSC_PRCL has been added to complement V1:LSC_PRCL_CORR-scatteredlight on vetoing scattered-light glitches
  • The threshold of V1:PSL_PMC_TRA_AC-pstab has been updated to better catch the high frequency PMC/PSTAB glitches (see plot)

All the veto channels are now tagged by "_2019-09-19". Note that no online process had to be restarted; only the input threshold files have been updated.

Images attached to this report
Search Help
×