Reports 1-1 of 1 Clear search Modify search
Environmental Monitoring (Environmental Monitoring)
fiori - 11:31 Thursday 10 May 2018 (41337) Print this report
Bruco scan results on 300s at 25MpC of May 8th

Here the links to Bruco tables, up to 500Hz:

Some high-lights about coherences with control signals:

  • 10-20 Hz dominates LSC_B1s2_DC (Figure 1)
  • 30-70 Hz LSC_MICH (Figure 2)
  • PRCL is broadband, but seems not dominant (Figure 3)
  • SSFS is mainly at 156 Hz and probably 150Hz and other 50Hz odd harmonics (Figure 4)
  • broad peaks (192, 208, 231-240, 276 Hz which correspond to old baptized "scattered light" structures) have some coherence (around 0.3) with signals  SDB1_B5_QD1 and Sc_NE_MAR_TZ_CORR (Figure 5)
  • above 300Hz Sc_NE_MAR_TZ_CORR is the winner (Figure 6)

Some high-lights about ENV and other safe channels:

  • no broadband contribution,
  • but few narrow peaks are coherent with CEB hall sound and vibration sensors: 333.5Hz (seems NEW), 393Hz (also NEW) and 463 Hz (this should be the big turbo)
  • 55.7 and 57.6 Hz peaks are coherent with 10MHz clocks (SIB2, SPRB)
  • BsX* have no coherence except peaks (also in SSFS) at 156 Hz,  401Hz (IB turbo pump?) and 405Hz

Figure 7 shows the overall projection, Figure 8 shows the projection by families, Figure 9 is the same but with linear x scale.

This is the list of most coherent channel at most prominent peaks:

% freq(Hz) ASD maxCOHE channel
f= 55.7 (ASD= 1.3e-22):  0.63 V1:SIB2_Clock_10MHz_mag
f= 57.6 (ASD= 2.1e-22):  0.66 V1:SPRB_Clock_10MHz_mag
f=157.2 (ASD= 6.9e-23):  0.75 V1:BsX_GLB05
f=256.8 (ASD= 4.2e-23):  0.11 V1:ENV_DT_W_FLANGE_ACC_Z
f=286.1 (ASD= 6.6e-23):  0.17 V1:ENV_SR_ACC_Z
f=288.6 (ASD= 6.6e-23):  0.18 V1:ENV_BS_ACC_Z
f=333.5 (ASD= 1.7e-22):  0.25 V1:ENV_NI_CT_ACC_Z
f=344.7 (ASD= 1.1e-22):  0.64 V1:BsX_QF_DC
f=383.8 (ASD= 6.1e-23):  0.16 V1:ENV_DT_ACC_Z
f=393.6 (ASD= 2.1e-22):  0.86 V1:ENV_CEB_MIC
f=401.4 (ASD= 4.2e-22):  0.96 V1:BsX_PZT_UVC
f=405.8 (ASD= 4.3e-23):  0.34 V1:BsX_QF_h
f=432.6 (ASD= 2.3e-23):  0.29 V1:ENV_SQZ_PIPE_ACC_Y
f=447.3 (ASD= 1.2e-20):  0.26 V1:SBE_EIB_sine
f=462.9 (ASD=   7e-24):  0.86 V1:ENV_SQZ_ACC_Y
 

Images attached to this report