Reports 1-1 of 1 Clear search Modify search
AdV-INJ (Input Mode Cleaner cavity)
derossi, allocca, bersanetti, pillant - 15:20 Friday 30 March 2018 (40961) Print this report
IMC Aa sensing matrix measurement

This morning we remeasured the IMC automatic alignment sensing matrix by injecting a line at 2 Hz, for 50 s, on the five degrees of freedom . The GPSs and the amplitudes for each one are given in the following table.

GPS dof amplitude
1206434124 IB tx 0.2
1206434244 IB ty 0.5
1206434361 IB tz 0.3
1206434511 MC tx 0.7
1206434580 MC ty 0.4

We then were able to close the automatic alignment in full bandwidth and lock the RFC.