AdV-COM (AdV commissioning (1st part) )Paoletti, Cavalieri - 14:45 Wednesday 30 August 2017 (39334)
Print this reportComment to More acoustic injections CEB (39322)
Today we performed another set of Acoustic Injections, here following is the time-table.
As a general remark, we suggest having a look inside time periods of each injection because the interferometer had some glitches (probably not correlated to injections).
It seems WEB was more sensitive to high acoustic levels respect to NEB (to be investigated a posteriori)
---
Morning: System moved to NEB
Two monitor speaker
Two sub-woofer
Level of Monitor speaker: 3/4 range
Level of Sub-woofer amplifier: FULL range
Noise is band-passed 10Hz --> 2kHz
Time is Local time
Quiet time
Aug30,17-09:49:25 -> GPS: 1188114581
Aug30,17-10:01:48 -> GPS: 1188115324
Noise level 0.006
Aug30,17-14:01:27 -> GPS: 1188129703
Visible drop of the horizon, B1p moving a lot in the camera, B7_DC and B8_DC very noisy (mainly in the Very Low frequency, say below 10Hz) – probably is an alignment sensitivity to AI ?
Aug30,17-14:04:08 -> GPS: 1188129864
Noise level back to 0.003
Aug30,17-14:08:11 -> GPS: 1188130107
Aug30,17-14:11:47 -> GPS: 1188130323
Quiet time
Aug30,17-14:13:06 -> GPS: 1188130402
Aug30,17-14:16:41 -> GPS: 1188130617
WEB AI ended at Aug30,17-14:16:41 -> GPS: 1188130617