Environmental Monitoring (Environmental Monitoring)travasso, fiori - 14:17 Thursday 27 July 2017 (38879)
Print this reportComment to Sea microseism statistics (36700)Taking into account the percentiles described in the log-entry 36700, we set the alert values of the Environmental Flag "SeaActivity" in the DMS.
Using the bandwidth 0.1Hz-1Hz, the flag is set as below:
BRMS(ENV_CEB_SEIS_N_50Hz): YELLOW if the value is above the 75th percentile (1.25e-6), RED if the value is above the 90th percentile (1.98e-6)
BRMS(ENV_CEB_SEIS_W_50Hz): YELLOW if the value is above the 75th percentile (1.52e-6), RED if the value is above the 90th percentile (2.46e-6)
BRMS(ENV_CEB_SEIS_V_50Hz): YELLOW if the value is above the 75th percentile (0.56e-6), RED if the value is above the 90th percentile (0.86e-6)