Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Data Acquisition and Global Control)
masserot - 18:06 Sunday 26 March 2017 (37037) Print this report
Acl v0r31p1

I restarted most of the ACL servers with the latest version, already in use since several days for LSC,ASC ACl servers.

Only ISYS_slow, ISYS_Acl and ISYS_EER_dac are stil running with the previous release v0r30p1 and must be restarted with the latest version

Comments to this report:
masserot - 14:56 Monday 27 March 2017 (37042) Print this report

With this release, there is a fast monitoring of the delay on the ACL_ADC_CH  channels meaning that

  • if a channel is absent
  • or if the channel content is not updated at each expected Tolm packect period

the ACL server become blue and print the list of the ACL_ADC_CH channels not  updated  intime or absent .

It seems to be the case for :

  • ISYS_moni and  the EER_ADC_INJ2  ADC7674
  • SDB2_Photodiodes and  SDB2_MezzPD0 service mezzanines