Injection System servers are configured for Scientific Linux and CMT.

INJ Tango servers have been configured for Scientific Linux and CMT. Changing the system is at the request of the EGO software manager.
To switch servers from cmplvtf ( debian / apt-get ) to tangoitf ( SL6 / cmt ) and vice-versa the commands ( illustrated in figures below ) are...

  setenv TANGO_HOST cmplvtf:10000; astor &   "Stop All"
  setenv TANGO_HOST tangoitf:10000;astor &   "Start All"

The tangoitf configuration creates the same problems for INJ system as the VAC system. These were reported in  VIR-0403A-16.pptx. i.e.
  *Many Tango tools do not work correctly
  *Long term tests are invalidated.
  *Tango community support is  limited due to EGO customisation.

==============================================================
The missing servers on tangoitf are....

*Access Control  works on cmplvtf  but not on tangoitf (yet?). See..
   #SPR 1206 Please enable TangoAccessControl on tangoitf

 *"Level 2" servers (.HDBArchiver/01 etc......) are the servers needed to use mambo . These servers work on cmplvtf but not on tangoitf. See..
   #SPR 1192 Please Install mambo on Scientific Linux.
   #SPR 1112 Some tango tools needed on virgoDev
==============================================================
Related SPRs

   #SPR 1205 astor does not work correctly using Tango v8r1p2 on tangoitf
   #SPR 1198 Please create a tango database for the INJ system.

Images attached to this report
Comments to this report:
carbognani - 8:44 Tuesday 18 April 2017 (37276) Print this report

This morning the INJ tango servers:

  • LaserChiller/EER
  • Lnfs100/LNFS
  • SL_TempController/EER

have been moved from cmplvtf to tangoitf. The corresponding DAQ bridges configuration has been upated and associated SMS data are back on the DAQ.

The pointer to Lnfs100/LNFS on the automation has been also updated.

Those servers can be managed from the astor instance which can be started from the IceWM menu: Injection-> astor