Reports 1-1 of 1 Clear search Modify search
Environmental Monitoring (Environmental Monitoring)
fiori, miller, swinkels - 14:38 Tuesday 19 July 2011 (29931) Print this report
tmp magnetic probe
Last Tuesday, in order to hunt the source of the Comb at 10.2782 Hz coming from the central building, we placed a temporarely magnetic probe at the WI suspension rack (we named it Em_MA_Susp_Rack_WI_tmp). No significant coherence was found. During this morning maintenance we used that same probe (and the onosokki) to sniff various devices around WI and NI towers, without success. We finally left the probe at the NI susp rack crate (we kept the same channel name).
Comments to this report:
fiori - 14:50 Thursday 21 July 2011 (29948) Print this report
moved to DAQ room, RACK 15, on crate C50 detection suspension. Same channel name.
fiori, paoletti, miller - 12:21 Tuesday 26 July 2011 (29972) Print this report
today we moved the same probe (same channel name) between tops of rack 17 (env monitoring) and rack 18 (calibration stuff) in DAQ room.
fiori, paoletti - 15:27 Friday 29 July 2011 (30001) Print this report
we moved the tmp magnetic probe in DAQ room to top of rack 23 (injection DSP) and rack 24 (Real Time PC), in between the two.
fiori - 12:29 Tuesday 02 August 2011 (30024) Print this report
I moved it in DAQ room between top of racks 12 and 13 (ethernet network). I changed the probe name, from Em_MA_Susp_Rack_WI_tmp to Em_MA_DAQ_tmp.