Lines at 3kHz on Bs_MOD_6MHz removed.
Following the recommendation of Alain Masserot, in order to remove the lines around 3kHz on Bs_MOD_6MHz signal we have unplugged one of the two coaxial cable that is going to the DAQ room. Now this signal is only acquired in EEroom.
As you can see (see plot) the lines around 3kHz have disappeared from this signal.
This could mean that this cable was acting as an antenna and maybe the spurious lines where entering in this cable along its path from the Laser lab to the DAQ room.
Note that these lines will probably be still visible on the dark fringe.
If needed we can replug this cable.
Images attached to this report
Comments to this report:
chiummo, genin - 9:45 Wednesday 15 June 2011 (29662) Print this report
Following a recommendation by DAQ, this morning we plugged the cable Bs_MOD_6MHz back in.