Fidecaro" class="link">Fidecaro - 7:05 Friday 31 July 2009 (23988) Print this report
Scientist report -
Unlock at GPS 933042630 (LT:04:30:15). Presence of helicopter/plane signal near central building. Was heard while outside. See attached plot.

Horizon
First two hours: horizon stable around or above 8 Mpc. One reconstruction (?) glitch at about 23:00.
Second two hours. idem. Unlock at about 4:30 local time. Back at 8 Mpc. Dip at 6:04 local time. Too early to be injection, sheduled at 6:08 local time, but...


Special Events
INJECTIONS during shift

23:09:30 933023385.93 sg554q25 1.3 -- 5.9e-23
23:09:40 933023395.32 zmA3B3G1 0.4 -- 2.33e-23
23:09:50 933023405.69 cusp220 8.0 -- 5.05e-21
00:16:40 933027415.00 insp(11.4,5.5)
05:06:22 933044797.86 zmA3B3G1 16.1 -- 1.04e-21
05:06:32 933044807.47 sg153q3c 7.1 -- 3.44e-22
05:06:42 933044817.91 gau1 17.4 -- 1.01e-21
06:08:04 933048499.60 sg554q3c 11.5 -- 5.63e-22
06:08:14 933048509.57 gau3 12.6 -- 1.55e-21
06:08:24 933048519.55 wnb250b100t30 9.0 -- 3.46e-22


Omega pipeline status
High SNR event found by Omega/MBTA
Fri 2009 Jul 31 00:33 933035641.688 936.2 3.09e-01 1772.6 72 Omega/MBTA
Fri 2009 Jul 31 01:58 933040752.975 693.4 1.84e-03 542.2 8 Omega -
Fri 2009 Jul 31 02:24 933042265.879 90.4 2.39e-02 100.3 10 Omega -
Fri 2009 Jul 31 03:11 933045125.895 103.5 1.05e-01 142.1 16 Omega -


MBTA events
SNR: 7.6 GPS: 933027250.721 Local Time: Jul31,09-00:13:56 (LF/HF band SNR: 3.0/7.4) wscan DQ flag(s) on:
Seismic origin


SNR: 8.3 GPS: 933024224.840 Local Time: Jul30,09-23:23:30 (LF/HF band SNR: 8.0/2.4) wscan DQ flag(s) on:
Seismic origin

Images attached to this report