New filter for DARM filtering
A new filter on the DARM filtering chain has been written: it is possible to find it in dBui as Locking_Half_Boost_MICHNEW1 version 1.4. We added 4 poles and 4 zeros to notch the excited violin modes (see the attached plots). We couldnā€˜t test it because the wind is too high, thus the ITF lock resulted difficult.
Images attached to this report
Comments to this report:
tarallom - 12:46 Wednesday 30 August 2006 (13223) Print this report
The correct Locking_Half_Boost_MICHNEW1 version is the # 1.6.