========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0061 Injection acquisition : SIG0062 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 78.25 10.058 8.78 0.628 138.0 1.67 - 100.25 12.096 11.31 0.891 122.2 3.32 - 146.50 5.197 4.93 0.904 152.3 6.90 - 169.50 12.873 12.80 0.707 128.1 2.56 - 355.00 38.568 37.02 0.777 137.0 2.28 - 382.75 6.523 6.16 0.936 97.1 3.61 - 425.75 12.630 12.84 0.913 286.8 8.89 Check phase rotation 439.75 7.606 4.95 0.746 147.4 2.58 - 461.50 8.270 6.81 0.921 117.9 7.01 - 483.50 9.220 7.68 0.738 101.0 1.72 - 508.00 11.492 10.09 0.693 225.3 6.15 Check phase rotation 562.00 6.484 5.55 0.545 187.3 9.40 - 574.75 13.486 11.66 0.821 190.8 3.58 - 587.25 13.877 5.30 0.738 88.2 1.30 - 597.25 39.898 35.86 0.850 215.1 7.21 - 622.50 10.316 5.49 0.886 88.9 2.91 - 638.75 20.173 17.44 0.542 127.2 4.93 - 648.50 11.772 9.51 0.763 82.1 1.72 - 654.75 11.936 6.50 0.698 160.9 2.09 - 663.25 14.491 11.38 0.735 62.2 3.77 - 703.00 23.562 18.08 0.919 77.9 3.43 - 721.00 8.334 6.72 0.506 68.2 1.81 - 738.00 8.034 6.37 0.804 155.3 5.78 - 755.50 13.050 11.87 0.766 149.7 2.57 - 799.25 8.966 7.87 0.744 456.2 11.27 Check phase rotation 809.75 7.832 6.31 0.672 108.6 3.34 - 829.25 8.305 7.02 0.890 138.6 4.36 - 875.00 9.566 9.24 0.908 72.6 6.42 - 931.75 13.306 12.55 0.557 112.7 2.56 - 942.75 11.597 4.03 0.724 79.1 4.66 -