========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0061 Injection acquisition : SIG0062 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 140.50 10.908 9.53 0.935 177.1 3.78 - 146.75 17.142 15.69 0.890 120.5 2.92 - 272.50 9.563 8.60 0.827 151.1 2.82 - 351.25 14.798 14.41 0.923 76.9 5.48 - 415.00 7.950 4.99 0.576 138.9 2.25 - 425.75 29.700 29.51 0.916 77.1 4.89 - 432.25 10.639 7.41 0.826 63.4 1.80 - 439.75 10.580 8.57 0.743 193.2 4.22 - 455.00 8.219 5.05 0.856 180.8 5.34 - 473.75 14.505 13.83 0.968 184.4 11.28 - 507.75 8.794 6.05 0.666 175.7 5.04 - 522.00 11.441 9.64 0.810 468.4 6.29 Check phase rotation 549.50 13.281 7.22 0.570 126.0 1.90 - 562.00 16.407 14.79 0.530 139.7 2.95 - 576.25 37.187 34.07 0.768 158.1 3.73 - 587.00 19.105 5.85 0.735 124.4 1.66 - 594.00 52.727 52.65 0.776 274.9 8.34 Check phase rotation 621.75 25.618 21.26 0.966 106.7 7.18 - 638.75 27.189 24.64 0.540 164.3 3.55 - 648.25 14.071 11.15 0.844 78.7 4.52 - 675.25 13.640 11.52 0.696 99.4 6.13 - 702.75 7.386 5.47 0.828 90.6 3.27 - 730.50 11.046 9.87 0.825 117.4 6.87 - 854.25 7.186 6.96 0.867 133.8 5.97 - 930.75 4.806 4.64 0.785 391.1 6.76 Check phase rotation