========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0059 Injection acquisition : SIG0060 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 68.25 51.436 51.42 0.576 114.3 1.13 - 78.25 17.494 13.33 0.697 91.0 1.17 - 100.25 9.690 8.95 0.867 119.2 2.62 - 123.00 7.691 6.45 0.813 146.2 4.69 - 145.00 4.486 4.20 0.714 104.6 6.29 - 163.00 12.184 11.43 0.690 130.8 3.15 - 168.50 7.934 6.74 0.530 72.0 3.34 - 179.25 21.368 17.94 0.565 159.7 3.44 - 185.50 10.180 7.59 0.617 119.8 1.79 - 244.75 14.126 13.93 0.514 176.6 2.34 - 272.25 6.266 5.91 0.844 142.0 3.05 - 355.50 5.017 4.97 0.808 176.9 1.72 - 441.75 6.618 5.53 0.538 68.3 4.09 -