========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0059 Injection acquisition : SIG0060 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 78.25 11.818 11.62 0.687 125.7 1.89 - 100.25 11.017 10.13 0.868 121.9 2.71 - 122.75 7.199 5.18 0.896 79.9 2.20 - 130.50 10.102 8.51 0.832 74.2 1.90 - 146.50 21.474 18.25 0.906 93.6 6.35 - 176.75 13.136 5.38 0.720 106.1 4.02 - 355.50 9.863 9.75 0.865 172.5 2.01 - 481.00 6.489 4.02 0.909 69.1 3.00 - 509.00 20.707 20.45 0.759 83.2 2.28 - 552.50 8.095 6.71 0.756 162.3 7.15 - 586.25 11.682 8.88 0.709 147.2 2.17 - 597.50 16.744 16.18 0.791 173.6 4.08 - 623.25 6.173 4.85 0.860 125.3 7.56 - 638.75 10.278 9.24 0.886 63.2 4.64 - 648.50 6.145 4.46 0.586 61.4 1.58 - 678.25 6.116 4.86 0.965 147.0 5.73 - 689.50 44.454 42.90 0.677 159.6 2.10 - 694.25 34.434 13.09 0.598 61.1 2.17 - 702.25 39.120 25.47 0.875 62.6 3.88 - 740.75 6.724 5.56 0.650 124.8 5.69 - 802.50 9.261 6.58 0.647 162.2 3.42 - 810.50 10.554 8.53 0.716 170.1 3.56 - 830.25 11.167 10.07 0.918 135.7 4.75 - 873.75 6.156 4.99 0.820 66.4 6.70 - 962.50 11.098 7.69 0.889 102.5 4.91 -