========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0059 Injection acquisition : SIG0060 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 125.00 13.351 5.53 0.624 68.0 3.25 - 140.75 34.150 25.11 0.890 127.5 2.23 - 147.00 72.920 68.82 0.896 79.6 3.15 - 154.25 15.186 4.78 0.503 77.6 3.46 - 272.50 6.431 6.04 0.845 139.0 2.88 - 425.00 22.634 21.25 0.765 93.2 5.75 - 510.25 20.825 7.76 0.635 117.4 1.19 - 527.25 41.388 41.34 0.863 245.9 7.68 Check phase rotation 540.00 18.093 11.23 0.517 97.3 2.22 - 544.75 9.141 5.46 0.812 129.4 2.94 - 552.25 19.746 17.08 0.718 182.9 5.80 - 568.00 9.560 5.63 0.903 84.8 3.07 - 580.50 7.873 4.80 0.788 76.2 2.36 - 586.25 18.477 11.99 0.739 111.8 1.84 - 597.50 22.033 19.66 0.748 168.6 2.58 - 613.50 19.252 17.13 0.899 63.2 6.45 - 625.50 16.646 7.09 0.706 162.7 6.53 - 638.75 14.689 12.77 0.891 99.4 3.28 - 650.50 8.090 5.79 0.770 200.8 4.74 - 674.75 4.964 4.32 0.794 93.2 4.25 - 689.50 23.711 21.93 0.705 125.7 2.64 - 694.25 16.352 6.92 0.548 69.4 2.53 - 702.25 13.210 6.67 0.869 63.2 3.26 - 738.25 6.676 5.91 0.762 61.2 4.22 - 825.75 4.326 4.24 0.927 168.3 8.73 - 853.50 8.563 8.11 0.933 124.1 5.38 - 954.75 10.655 9.59 0.674 111.0 3.26 -