========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0053 Injection acquisition : SIG0054 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 108.00 4.415 4.04 0.974 312.1 10.11 Check phase rotation 123.00 9.020 7.86 0.747 146.2 2.02 - 170.50 12.587 12.30 0.872 124.5 2.42 - 244.75 5.770 5.48 0.826 141.0 2.66 - 355.25 34.834 34.02 0.558 115.7 2.29 - 421.00 8.496 8.03 0.658 151.4 8.42 - 440.00 6.448 6.14 0.735 176.0 4.08 - 483.50 11.489 8.04 0.754 113.1 1.86 - 485.75 9.338 4.33 0.630 68.4 1.14 - 505.50 24.136 23.91 0.896 158.6 7.63 - 557.25 15.318 14.35 0.862 112.3 3.82 - 576.50 34.269 30.90 0.781 157.2 4.48 - 597.50 21.084 17.51 0.853 417.4 12.07 Check phase rotation 613.50 7.615 6.17 0.963 71.0 4.76 - 623.25 7.742 5.84 0.902 91.0 5.20 - 630.25 8.025 7.29 0.799 100.7 2.86 - 670.25 30.184 19.26 0.793 72.6 4.78 - 687.00 15.456 5.93 0.666 94.4 2.21 - 694.50 14.842 10.35 0.766 119.7 2.66 - 711.50 19.674 18.34 0.974 77.3 11.99 - 736.25 11.552 10.55 0.543 242.0 4.19 Check phase rotation 757.75 8.273 6.43 0.573 176.4 6.13 - 829.00 15.859 14.69 0.918 172.7 9.46 - 845.75 11.106 10.39 0.900 228.0 7.84 Check phase rotation 905.25 7.812 6.46 0.872 65.2 4.99 - 932.75 28.242 27.52 0.626 264.3 6.61 Check phase rotation