========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0051 Injection acquisition : SIG0052 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 123.00 43.119 43.10 0.855 99.0 1.78 - 142.25 11.156 8.95 0.932 66.8 7.99 - 162.75 16.370 11.01 0.576 142.3 2.45 - 169.50 31.073 31.18 0.747 104.0 3.29 - 197.25 5.807 4.31 0.644 141.5 3.24 - 356.00 6.385 5.41 0.711 209.3 3.07 - 456.50 11.729 7.97 0.890 118.6 5.34 - 526.75 7.116 5.42 0.742 78.4 1.92 - 553.25 5.924 4.15 0.846 243.8 4.50 Check phase rotation 580.75 9.928 8.39 0.889 83.4 3.78 - 597.75 13.120 11.57 0.742 153.5 3.90 - 646.00 9.398 8.05 0.702 244.1 10.99 Check phase rotation 678.25 11.747 5.15 0.985 71.6 4.82 - 688.50 13.667 13.38 0.945 128.6 5.37 - 694.25 12.206 7.95 0.683 90.2 2.52 - 700.75 8.360 5.37 0.858 74.3 3.38 - 726.00 5.492 4.22 0.742 115.5 3.49 - 739.50 19.605 18.83 0.681 181.6 4.89 - 809.00 6.887 4.36 0.824 81.1 1.66 - 815.50 13.169 12.46 0.835 146.2 5.00 - 866.75 15.149 15.30 0.830 142.8 9.53 - 937.00 13.735 9.57 0.739 117.2 9.96 -