========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0051 Injection acquisition : SIG0052 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 68.25 6.004 5.91 0.829 74.6 1.43 - 108.00 5.153 4.75 0.980 161.4 7.94 - 123.00 32.093 31.65 0.875 95.5 1.67 - 244.75 7.921 7.12 0.620 180.9 2.62 - 356.00 11.362 9.30 0.741 179.4 2.39 - 474.75 14.252 12.59 0.762 156.8 2.56 - 514.75 41.611 40.13 0.820 218.8 3.95 - 536.75 6.157 5.42 0.909 109.7 4.06 - 552.75 14.652 13.96 0.741 252.0 7.26 Check phase rotation 567.00 7.866 5.00 0.810 106.0 3.39 - 581.00 10.858 8.77 0.824 123.5 4.60 - 597.75 8.924 6.51 0.760 151.7 4.32 - 624.50 6.966 5.56 0.906 82.9 3.40 - 667.50 11.156 9.11 0.948 133.5 12.09 - 679.00 15.817 9.27 0.965 102.2 4.32 - 694.25 16.556 15.86 0.738 139.0 3.99 - 709.75 15.362 12.76 0.917 87.7 5.69 - 738.25 7.430 6.43 0.744 161.3 4.38 - 808.75 5.046 4.06 0.813 105.9 2.94 - 825.75 20.762 19.88 0.952 206.0 9.85 - 845.50 9.648 4.18 0.903 120.1 4.89 - 853.50 10.516 9.71 0.919 189.2 16.08 - 865.75 7.859 4.14 0.828 85.2 5.29 - 937.50 10.102 9.55 0.920 127.1 13.12 -