========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0055 Injection acquisition : SIG0056 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 123.00 20.326 20.30 0.850 99.0 2.12 - 142.00 13.117 10.30 0.811 174.7 10.16 - 158.25 6.465 5.50 0.597 80.7 1.41 - 170.50 19.794 18.57 0.876 215.0 3.58 - 423.75 10.125 9.50 0.503 177.8 4.65 - 440.25 11.716 9.69 0.878 75.8 4.41 - 577.75 29.583 29.02 0.649 126.6 5.34 - 586.50 8.193 4.69 0.755 84.7 1.53 - 590.25 9.811 6.49 0.863 96.7 2.73 - 597.75 12.840 11.63 0.909 115.9 4.00 - 653.75 8.553 5.43 0.889 68.7 1.46 - 662.00 20.441 16.71 0.869 109.7 5.80 - 738.00 5.387 4.49 0.749 160.5 5.97 - 757.50 7.995 7.81 0.539 139.1 10.06 - 814.75 5.643 5.77 0.786 137.2 6.75 - 839.25 4.905 4.32 0.559 164.9 3.77 - 882.25 9.038 6.97 0.532 170.4 2.81 - 894.75 6.822 5.58 0.845 60.5 7.48 - 920.25 7.029 5.31 0.569 63.6 5.57 - 942.75 7.813 8.16 0.775 111.6 10.21 -