========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0049 Injection acquisition : SIG0050 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 119.25 13.709 10.55 0.893 92.7 2.31 - 131.25 50.806 46.80 0.915 97.7 3.50 - 175.75 8.536 7.61 0.674 76.3 7.40 - 227.50 12.419 11.76 0.695 136.8 6.24 - 240.25 4.666 4.12 0.583 109.3 2.53 - 294.50 15.057 15.02 0.711 108.0 2.68 - 308.00 6.894 5.56 0.578 341.3 5.71 Check phase rotation 326.75 16.472 15.92 0.880 129.8 2.46 - 335.75 16.563 12.64 0.919 114.2 2.57 - 351.50 37.655 37.41 0.958 129.1 3.97 - 365.50 10.682 7.68 0.934 121.3 2.66 - 386.75 14.740 8.21 0.671 97.8 2.26 - 399.00 33.315 32.34 0.757 129.8 3.51 - 407.25 19.895 17.01 0.857 87.9 2.07 - 426.25 17.163 11.93 0.849 152.5 11.36 - 458.75 11.869 10.11 0.647 165.9 4.67 - 468.25 14.565 12.73 0.889 122.4 5.79 - 503.50 11.614 6.66 0.839 71.3 2.62 - 508.75 16.715 15.22 0.970 162.4 5.01 - 524.75 32.863 31.02 0.855 71.1 3.46 - 564.00 11.766 7.75 0.834 83.5 5.16 - 579.25 11.753 5.18 0.793 113.2 2.44 - 614.00 8.512 7.96 0.759 70.1 7.10 - 624.25 7.724 6.49 0.594 224.0 3.38 Check phase rotation 788.25 7.368 7.05 0.610 204.2 2.66 -