========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0045 Injection acquisition : SIG0046 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 119.00 15.964 12.70 0.856 101.4 2.30 - 131.25 46.728 46.69 0.901 116.5 3.61 - 180.25 9.798 4.03 0.725 175.0 6.01 - 228.00 15.068 13.66 0.764 119.9 5.88 - 294.50 18.157 15.59 0.753 93.9 2.76 - 308.00 7.202 5.55 0.703 330.5 5.49 Check phase rotation 326.75 16.875 16.34 0.854 129.8 2.45 - 335.75 17.635 13.04 0.946 115.6 2.55 - 351.75 38.178 38.00 0.938 137.4 3.92 - 365.50 9.417 6.15 0.914 138.8 3.63 - 386.25 14.381 11.28 0.626 263.7 7.44 Check phase rotation 399.25 30.809 29.74 0.668 93.5 2.80 - 407.00 20.565 16.82 0.861 118.6 2.52 - 425.75 17.475 13.14 0.857 158.5 11.40 - 458.50 12.421 10.57 0.715 153.9 4.70 - 468.25 14.049 12.64 0.912 126.8 5.73 - 503.50 11.905 5.49 0.875 61.1 2.18 - 508.25 14.625 12.76 0.963 139.0 4.62 - 525.00 28.576 25.34 0.677 71.2 3.45 - 564.50 10.163 4.52 0.909 60.2 5.25 - 617.75 7.787 6.97 0.921 70.4 7.17 - 624.50 7.163 4.69 0.725 194.6 3.30 - 788.00 7.361 7.32 0.778 177.1 2.81 -