========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0045 Injection acquisition : SIG0046 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 64.25 8.933 7.81 0.612 99.0 2.33 - 80.50 10.840 5.21 0.567 107.1 1.37 - 129.25 25.938 21.17 0.844 120.3 3.45 - 180.50 6.525 5.66 0.651 75.1 6.92 - 198.75 6.671 6.40 0.864 121.9 4.29 - 253.50 5.468 5.17 0.704 129.2 4.87 - 294.50 6.090 5.21 0.715 72.4 2.81 - 326.75 4.661 4.15 0.843 128.0 2.35 - 351.75 30.647 30.18 0.938 140.0 3.95 - 361.50 11.331 8.13 0.923 97.2 3.32 - 377.50 8.154 4.03 0.966 95.6 5.02 - 391.75 10.598 6.97 0.971 61.5 4.54 - 399.25 40.238 40.19 0.671 93.5 2.79 - 407.25 27.830 19.79 0.873 404.2 6.03 Check phase rotation 444.25 18.097 16.61 0.875 153.1 4.18 - 458.00 9.681 7.39 0.805 121.8 2.48 - 467.75 19.555 17.70 0.867 419.6 6.39 Check phase rotation 479.50 16.818 9.39 0.721 154.8 2.38 - 508.00 29.504 28.84 0.960 103.6 7.05 - 583.00 13.092 10.33 0.612 245.9 3.44 Check phase rotation 686.50 7.133 6.72 0.617 158.7 5.36 - 903.00 5.065 4.77 0.887 130.8 11.89 -