========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0043 Injection acquisition : SIG0044 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 119.50 27.059 24.30 0.732 112.5 1.81 - 131.00 55.579 55.55 0.841 155.4 2.79 - 228.00 11.834 10.85 0.808 146.2 5.87 - 294.75 6.709 6.30 0.792 144.3 3.17 - 311.50 4.407 4.25 0.936 251.3 6.24 Check phase rotation 326.75 14.311 12.32 0.839 132.5 2.35 - 335.50 9.912 5.21 0.949 89.3 2.22 - 352.25 45.322 45.99 0.950 99.4 4.08 - 365.75 13.304 10.26 0.937 156.0 4.56 - 386.25 13.291 11.00 0.763 259.5 6.82 Check phase rotation 399.00 27.567 24.07 0.644 96.2 2.02 - 412.75 13.587 10.96 0.884 179.5 11.48 - 433.00 17.262 15.23 0.941 103.6 10.90 - 471.25 18.123 17.66 0.768 171.6 6.01 - 501.50 23.215 19.62 0.801 155.3 4.13 - 509.00 31.497 31.17 0.906 126.9 3.28 - 516.00 23.976 21.31 0.855 172.1 4.95 - 524.75 11.783 6.67 0.977 83.9 3.50 - 570.75 7.143 4.74 0.802 76.7 2.32 - 602.25 12.993 9.91 0.812 92.7 4.39 - 614.75 13.988 13.10 0.921 93.2 7.76 - 624.50 9.838 6.62 0.805 201.2 3.53 - 767.00 4.209 4.04 0.945 137.5 12.04 -