========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0043 Injection acquisition : SIG0044 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 64.00 8.576 8.50 0.866 128.3 2.18 - 80.50 7.814 5.84 0.507 151.0 1.54 - 131.00 21.467 21.45 0.812 150.6 2.89 - 214.75 5.793 5.54 0.741 246.9 5.62 Check phase rotation 416.25 4.121 4.10 0.933 142.7 9.42 -