========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0038 Injection acquisition : SIG0040 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 57.50 9.637 9.62 0.677 67.8 1.22 - 80.50 7.239 4.99 0.570 146.8 1.95 - 131.00 5.369 4.88 0.720 235.0 3.91 Check phase rotation 164.00 9.106 8.75 0.571 164.0 3.21 - 339.25 6.997 6.40 0.967 141.8 4.99 - 355.00 10.738 8.55 0.917 107.7 4.48 - 366.75 7.954 4.87 0.895 176.1 2.10 - 370.50 11.668 8.60 0.792 137.7 2.03 - 407.25 5.194 4.22 0.856 107.5 2.28 - 475.50 4.346 4.21 0.886 105.3 3.53 -