========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0038 Injection acquisition : SIG0040 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 80.50 8.434 5.10 0.597 120.4 1.69 - 105.50 7.409 4.37 0.765 101.8 1.58 - 122.50 9.987 7.49 0.780 75.1 3.43 - 131.00 44.936 44.78 0.685 242.5 2.38 Check phase rotation 182.50 4.162 4.64 0.633 124.6 4.19 - 294.75 18.061 17.25 0.802 164.4 2.94 - 328.00 40.950 32.93 0.911 100.0 3.46 - 339.25 92.314 85.79 0.958 194.3 5.36 - 345.25 61.090 51.59 0.824 136.1 1.57 - 355.00 66.609 49.82 0.920 105.4 8.12 - 365.75 101.599 79.38 0.948 108.6 3.28 - 370.75 74.357 44.63 0.865 96.7 2.09 - 386.75 252.130 218.23 0.601 158.7 2.79 - 399.25 24.950 13.43 0.645 266.8 6.02 Check phase rotation 407.25 39.111 26.80 0.823 107.6 2.18 - 415.00 25.157 12.07 0.970 70.5 5.24 - 457.50 13.873 9.03 0.876 96.8 2.09 - 469.00 16.059 4.62 0.941 60.5 1.85 - 475.50 24.609 21.24 0.878 102.6 3.34 - 480.00 23.214 4.10 0.725 64.9 1.24 - 484.00 36.512 22.35 0.814 78.4 2.40 - 495.75 32.672 30.44 0.912 145.3 6.74 - 505.75 14.898 11.77 0.651 166.7 4.04 - 565.50 21.349 15.84 0.948 91.7 3.15 - 582.00 15.402 12.65 0.829 115.4 5.87 - 608.00 110.352 109.13 0.946 119.4 13.89 - 626.50 105.736 92.35 0.576 190.1 2.89 - 651.25 45.217 42.29 0.903 134.8 3.64 - 745.50 4.287 4.08 0.827 265.2 6.74 Check phase rotation 878.25 6.471 5.71 0.748 71.7 4.18 - 938.75 6.343 6.06 0.769 88.6 5.21 -