========================================================== Candidate mechanical resonance modes ========================================================== Instrumented baffle : NI Triaxial accelerometer position : TOP Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0041 Injection acquisition : SIG0042 Candidate resonance selection criteria -------------------------------------- Peak prominence > 4.0 Coherence > 0.50 Phase rotation > 60 deg Freq [Hz] TF Mag. Prom. Coh. Phase Rot. [deg] Width Comment ----------------------------------------------------------------------------------------------- 80.25 8.643 8.56 0.524 120.0 2.20 - 122.50 28.514 20.76 0.519 70.5 1.15 - 228.00 5.427 4.30 0.678 137.9 5.21 - 314.75 5.699 5.44 0.682 116.5 2.17 - 328.25 5.740 4.78 0.938 110.7 2.83 - 340.00 12.355 9.94 0.954 160.5 4.23 - 363.00 11.725 9.97 0.718 185.0 4.41 - 386.25 13.983 12.27 0.813 70.9 2.45 - 469.00 38.517 38.26 0.926 119.1 4.79 - 479.00 20.571 14.29 0.702 114.8 3.33 - 495.75 21.762 19.38 0.924 117.4 5.85 - 515.75 16.746 14.44 0.905 306.3 9.52 Check phase rotation 519.00 10.596 4.12 0.680 237.7 2.63 Check phase rotation 602.00 33.511 12.00 0.863 81.0 2.09 - 610.75 33.054 32.72 0.933 157.3 15.72 - 627.50 11.273 10.03 0.941 112.9 5.95 - 638.00 8.465 4.80 0.898 62.1 3.78 - 746.50 5.002 4.87 0.812 132.3 4.36 - 767.00 5.003 4.89 0.921 68.3 3.68 - 957.25 3.957 4.13 0.621 67.3 6.74 -