========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0061 Injection acquisition : SIG0062 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -8.36063471e-03 0.00000000e+00 8.36063471e-03 3.14159265 0.09592673 0.25 -7.60263632e-03 -7.60903076e-04 7.64061860e-03 -3.04184073 0.09162945 0.50 -2.72201209e-03 -1.92007356e-03 3.33107075e-03 -2.52726000 0.06413019 0.75 -3.97175175e-03 -1.59695543e-03 4.28078015e-03 -2.75929587 0.06658439 1.00 -6.58116580e-03 3.79632798e-04 6.59210622e-03 3.08397177 0.11673302 1.25 -4.13371548e-03 -1.28529363e-03 4.32892404e-03 -2.84013930 0.05575782 1.50 -3.12109267e-03 -3.32338136e-03 4.55917570e-03 -2.32481531 0.04613867 1.75 -3.46061901e-03 -9.42054251e-04 3.58655129e-03 -2.87581160 0.02286781 2.00 -4.58389501e-03 1.05492376e-03 4.70371742e-03 2.91539417 0.03100546 2.25 -4.26391684e-03 -2.72957834e-03 5.06276454e-03 -2.57216774 0.03821050 2.50 -2.46503008e-03 -2.33232436e-03 3.39353948e-03 -2.38384971 0.01442266 2.75 -2.91910048e-03 -5.66528972e-03 6.37311973e-03 -2.04657773 0.04761869 3.00 -3.71772243e-03 -7.84685347e-03 8.68300463e-03 -2.01325297 0.06556552 3.25 -3.24345460e-03 -2.14129787e-03 3.88653500e-03 -2.55808697 0.01215645 3.50 -2.73423859e-03 -1.02849874e-03 2.92127888e-03 -2.78180937 0.00575325 3.75 -3.64651862e-03 -4.29343353e-03 5.63299827e-03 -2.27489814 0.02016878 4.00 -3.86720584e-03 -5.82223680e-03 6.98954379e-03 -2.15709837 0.02499183 4.25 -2.23208143e-03 -3.84976415e-03 4.45004175e-03 -2.09622815 0.01249669 4.50 -2.03315924e-03 -2.64102446e-03 3.33297865e-03 -2.22687292 0.00680217 4.75 -3.75290675e-03 -4.14535081e-03 5.59180136e-03 -2.30654790 0.01804984 5.00 -4.01731334e-03 -5.51827100e-03 6.82569567e-03 -2.20006955 0.02207064 5.25 -3.37508058e-03 -5.60695981e-03 6.54439968e-03 -2.11264464 0.01687973 5.50 -4.22679365e-03 -4.65881156e-03 6.29049360e-03 -2.30761277 0.01376575 5.75 -3.96987178e-03 -1.01393155e-02 1.08887833e-02 -1.94398191 0.03400874 6.00 -1.53711561e-03 -7.60452111e-03 7.75831591e-03 -1.77024086 0.01791908 6.25 5.12330997e-04 -8.54878429e-03 8.56412260e-03 -1.51093765 0.02196052 6.50 -4.06273062e-04 -9.79354957e-03 9.80197281e-03 -1.61225629 0.02379074 6.75 -4.15769426e-03 -1.21200241e-02 1.28133293e-02 -1.90126034 0.03636414 7.00 -1.93909487e-03 -1.12601158e-02 1.14258609e-02 -1.74133279 0.02759506 7.25 1.94044684e-03 -1.03237806e-02 1.05045600e-02 -1.38500506 0.02452826 7.50 5.99604015e-04 -7.81721884e-03 7.84018083e-03 -1.49424324 0.01379502 7.75 -2.18663872e-03 -5.13486382e-03 5.58105862e-03 -1.97337962 0.00616095 8.00 -3.23200349e-03 -6.43402548e-03 7.20017572e-03 -2.03630613 0.01019297 8.25 -7.32312364e-03 -7.36580209e-03 1.03866828e-02 -2.35328901 0.01932414 8.50 -4.57102480e-03 -1.21401134e-02 1.29721479e-02 -1.93090105 0.02850851 8.75 -4.18444764e-03 -9.79630548e-03 1.06525679e-02 -1.97448281 0.01783763 9.00 -2.52996436e-03 -6.00019540e-03 6.51176354e-03 -1.96982352 0.00660862 9.25 -3.02155495e-03 -1.28645912e-02 1.32146699e-02 -1.80148865 0.02583262 9.50 -4.53184040e-03 -1.20862902e-02 1.29079816e-02 -1.92952939 0.02363538 9.75 -9.54197120e-03 -1.40597855e-02 1.69919623e-02 -2.16706377 0.03583202 10.00 -3.78026432e-03 -1.55582770e-02 1.60109457e-02 -1.80915189 0.03134524 10.25 -1.29361803e-03 -1.53584421e-02 1.54128255e-02 -1.65482645 0.02568113 10.50 -1.48279147e-03 -1.29299674e-02 1.30147120e-02 -1.68497621 0.01870803 10.75 -4.45312284e-04 -8.43704461e-03 8.44878837e-03 -1.62352800 0.00811035 11.00 -2.93286955e-03 -1.22411856e-02 1.25876268e-02 -1.80595390 0.01881214 11.25 -1.22417871e-03 -9.91791979e-03 9.99318501e-03 -1.69360616 0.01139811 11.50 -1.00715671e-03 -1.06712032e-02 1.07186260e-02 -1.66489838 0.01151310 11.75 1.94036824e-03 -1.13477898e-02 1.15124872e-02 -1.40144331 0.01133038 12.00 1.13702090e-03 -1.49969550e-02 1.50399958e-02 -1.49512431 0.01886309 12.25 4.05251326e-03 -1.58442900e-02 1.63543385e-02 -1.32039335 0.02303751 12.50 -9.59563936e-04 -1.28755739e-02 1.29112806e-02 -1.64518473 0.01436369 12.75 -4.67457616e-03 -1.68546230e-02 1.74908542e-02 -1.84134305 0.02506035 13.00 -4.24410997e-03 -1.91921212e-02 1.96557875e-02 -1.78843197 0.02971737 13.25 -5.72022715e-03 -2.48528930e-02 2.55026918e-02 -1.79701993 0.04414289 13.50 3.58263879e-04 -1.54424812e-02 1.54466365e-02 -1.54760060 0.01549796 13.75 1.93092889e-03 -7.83396668e-03 8.06842737e-03 -1.32913180 0.00428501 14.00 -4.72451370e-04 -1.00999571e-02 1.01110011e-02 -1.61753982 0.00627471 14.25 -1.55081905e-03 -9.58068141e-03 9.70538490e-03 -1.73127378 0.00567801 14.50 2.96869928e-03 -2.15932877e-02 2.17964045e-02 -1.43417034 0.02524140 14.75 2.09109864e-03 -2.44613361e-02 2.45505531e-02 -1.48551779 0.03076465 15.00 3.96122198e-03 -2.14998111e-02 2.18616824e-02 -1.38859516 0.02132679 15.25 3.65416088e-03 -1.91854152e-02 1.95303111e-02 -1.38258508 0.01698133 15.50 3.52519085e-03 -5.89442135e-03 6.86812737e-03 -1.03180786 0.00230240 15.75 4.22191111e-03 -1.16045378e-02 1.23486773e-02 -1.22186709 0.00704234 16.00 2.53086830e-03 -2.34096839e-02 2.35460951e-02 -1.46310259 0.02642768 16.25 5.66946131e-03 -2.26704791e-02 2.33686416e-02 -1.32574121 0.02583790 16.50 -2.43887522e-03 -1.88228356e-02 1.89801805e-02 -1.69964848 0.01547309 16.75 3.30274247e-03 -1.41286696e-02 1.45095628e-02 -1.34115814 0.00859613 17.00 -1.21928477e-02 -6.95844569e-03 1.40387144e-02 -2.62299672 0.00829607 17.25 -1.19886014e-02 -1.42503085e-02 1.86225094e-02 -2.27021033 0.01420309 17.50 -4.90802623e-03 -2.72724901e-02 2.77106015e-02 -1.74885297 0.03178231 17.75 -5.01129642e-03 -2.50575478e-02 2.55537432e-02 -1.76818371 0.02558441 18.00 -6.94375253e-03 -2.58334257e-02 2.67503566e-02 -1.83337953 0.02392514 18.25 -2.81641250e-03 -2.88654222e-02 2.90024960e-02 -1.66805892 0.02882038 18.50 -1.06177518e-03 -2.13890001e-02 2.14153378e-02 -1.62039679 0.01606615 18.75 -3.08288943e-03 -1.86852352e-02 1.89378515e-02 -1.73431386 0.01188266 19.00 3.66049681e-03 -2.00691691e-02 2.04002643e-02 -1.39038545 0.01083592 19.25 -3.22889478e-03 -2.68839570e-02 2.70771657e-02 -1.69032866 0.02067129 19.50 3.56370724e-03 -2.92905681e-02 2.95065652e-02 -1.44972400 0.02543712 19.75 -5.68533568e-04 -2.53278495e-02 2.53342296e-02 -1.59323953 0.01860028 20.00 -6.00340606e-05 -2.66759243e-02 2.66759919e-02 -1.57304682 0.02140316 20.25 5.20823762e-03 -1.99474045e-02 2.06161268e-02 -1.31539959 0.01258152 20.50 7.81508808e-03 -2.40383825e-02 2.52768558e-02 -1.25646609 0.01591162 20.75 1.47103897e-03 -3.64540930e-02 3.64837615e-02 -1.53046502 0.03051844 21.00 -6.40062239e-03 -3.97123988e-02 4.02249001e-02 -1.73059647 0.02980017 21.25 1.77799476e-03 -2.77323585e-02 2.77892960e-02 -1.50677131 0.01629786 21.50 8.68059826e-03 -1.62294951e-02 1.84051432e-02 -1.07964684 0.00714427 21.75 6.94751926e-03 -3.08171815e-02 3.15906110e-02 -1.34906023 0.02231240 22.00 4.14152344e-03 -2.92672096e-02 2.95587851e-02 -1.43022238 0.01893959 22.25 -3.65655080e-03 -3.43043414e-02 3.44986695e-02 -1.67698686 0.02195625 22.50 7.88034113e-03 -3.34351910e-02 3.43512994e-02 -1.33933055 0.01845641 22.75 1.35156840e-02 -3.57692839e-02 3.82376174e-02 -1.20952301 0.02498095 23.00 1.67905270e-02 -5.18430311e-02 5.44942353e-02 -1.25758464 0.04740920 23.25 2.14281756e-02 -3.55556959e-02 4.15135426e-02 -1.02841953 0.02628239 23.50 2.79685531e-02 -2.85776855e-02 3.99865486e-02 -0.79617003 0.02166166 23.75 1.24401926e-02 -2.34270243e-02 2.65251552e-02 -1.08264263 0.00856899 24.00 2.87351499e-02 -2.55993347e-02 3.84842146e-02 -0.72774895 0.01486611 24.25 2.93434652e-02 -4.30276280e-02 5.20808575e-02 -0.97227517 0.03683274 24.50 2.62058356e-02 -2.31987777e-02 3.49989872e-02 -0.72460723 0.01597121 24.75 3.09971700e-02 -3.22142284e-02 4.47054925e-02 -0.80464956 0.02019167 25.00 2.37263789e-02 -5.54621838e-02 6.03240821e-02 -1.16656168 0.03712226 25.25 -6.83137701e-03 -5.81884005e-02 5.85880335e-02 -1.68766238 0.03811344 25.50 -1.33816533e-02 -5.67599102e-02 5.83160017e-02 -1.80232734 0.03448970 25.75 2.48990691e-02 -2.58707872e-02 3.59062846e-02 -0.80453549 0.01502959 26.00 1.74202172e-02 -1.81749845e-02 2.51752662e-02 -0.80659917 0.00723999 26.25 -4.32062573e-03 -5.07028747e-02 5.08866320e-02 -1.65580557 0.02883041 26.50 -9.06711420e-03 -5.58251591e-02 5.65567056e-02 -1.73181015 0.03606293 26.75 -4.58053403e-04 -2.57181088e-02 2.57221876e-02 -1.58860498 0.00805327 27.00 -8.73093406e-03 -4.02393075e-02 4.11756126e-02 -1.78445970 0.01955496 27.25 1.50408955e-02 -4.11123069e-02 4.37772808e-02 -1.22007251 0.02286555 27.50 1.71113166e-02 -3.78676973e-02 4.15542976e-02 -1.14638751 0.01982904 27.75 3.66331015e-02 -6.41874458e-02 7.39054283e-02 -1.05218403 0.05499249 28.00 2.78918810e-02 -4.90386600e-02 5.64158417e-02 -1.05365416 0.03263789 28.25 3.27964219e-02 -4.26876711e-02 5.38316130e-02 -0.91569332 0.02581742 28.50 1.60493729e-02 -4.24906167e-02 4.54206437e-02 -1.20964690 0.01970394 28.75 -1.08825831e-03 -6.08262872e-02 6.08360216e-02 -1.58868567 0.03980350 29.00 1.69888917e-02 -5.85329390e-02 6.09485635e-02 -1.28831294 0.03943816 29.25 5.19642314e-02 -4.19973942e-02 6.68136398e-02 -0.67971984 0.04513412 29.50 2.22172659e-02 -3.55681625e-02 4.19368703e-02 -1.01245656 0.01769388 29.75 -4.88731974e-03 -5.27003460e-02 5.29264807e-02 -1.66326974 0.02499995 30.00 -3.95385510e-03 -6.06990205e-02 6.08276586e-02 -1.63584313 0.03095772 30.25 1.64645232e-02 -6.89280779e-02 7.08672029e-02 -1.33632456 0.03405818 30.50 2.20291357e-02 -6.07239590e-02 6.45963003e-02 -1.22278628 0.03065453 30.75 7.05468619e-03 -6.23133801e-02 6.27114498e-02 -1.45806331 0.02788455 31.00 8.23471399e-03 -4.78321854e-02 4.85358473e-02 -1.40030912 0.01929463 31.25 1.73345315e-02 -6.56764574e-02 6.79255698e-02 -1.31274291 0.03976411 31.50 1.95290378e-02 -6.64892334e-02 6.92979182e-02 -1.28511340 0.03795584 31.75 4.45455062e-02 -8.50709940e-02 9.60279967e-02 -1.08842593 0.05751329 32.00 2.16478363e-02 -4.51465292e-02 5.00683324e-02 -1.12368144 0.01810958 32.25 3.67574169e-02 -1.74598240e-02 4.06934043e-02 -0.44344947 0.01173941 32.50 2.22751274e-02 -3.40485421e-02 4.06876457e-02 -0.99146247 0.01063103 32.75 1.59774411e-02 -1.54684827e-02 2.22385382e-02 -0.76921438 0.00311877 33.00 1.70069960e-02 -3.01113329e-02 3.45822250e-02 -1.05665850 0.00866877 33.25 1.92600017e-02 -3.19223219e-02 3.72824664e-02 -1.02792484 0.00893169 33.50 3.14739610e-02 -3.87461343e-02 4.99186653e-02 -0.88859285 0.01528041 33.75 3.85073595e-02 -5.55359302e-02 6.75799991e-02 -0.96452890 0.02618960 34.00 2.01459944e-02 -6.44982087e-02 6.75712958e-02 -1.26804842 0.02050719 34.25 4.34345723e-02 -7.90424966e-02 9.01902342e-02 -1.06833007 0.03270727 34.50 1.99648928e-02 -4.12248829e-02 4.58048897e-02 -1.11979367 0.01072994 34.75 3.05511843e-02 -2.94622481e-02 4.24428901e-02 -0.76725528 0.00916571 35.00 8.84064090e-02 -6.92035272e-02 1.12271195e-01 -0.66415771 0.05718036 35.25 8.67705194e-02 -8.69648762e-02 1.22849553e-01 -0.78651686 0.06546290 35.50 4.52019060e-02 -6.06100458e-02 7.56094569e-02 -0.92999994 0.02702849 35.75 4.32427655e-02 -6.23347969e-02 7.58654313e-02 -0.96429898 0.02946726 36.00 2.82300144e-02 -7.32900650e-02 7.85389543e-02 -1.20312898 0.02769914 36.25 3.60778385e-02 -6.11427686e-02 7.09932995e-02 -1.03771848 0.01863348 36.50 9.95304287e-02 -7.60108935e-02 1.25235627e-01 -0.65220847 0.03097609 36.75 1.03684240e-01 -9.25443211e-02 1.38977959e-01 -0.72868891 0.04695941 37.00 5.80495442e-02 -2.54676748e-02 6.33904728e-02 -0.41343657 0.01366527 37.25 7.98901960e-02 -3.56650224e-02 8.74896407e-02 -0.41987741 0.02480970 37.50 7.67464558e-02 -2.62915507e-02 8.11249907e-02 -0.33004643 0.01919688 37.75 6.94358804e-02 -3.00690553e-02 7.56669648e-02 -0.40866741 0.01499800 38.00 5.87475317e-02 -7.48676628e-02 9.51653268e-02 -0.90546381 0.02330211 38.25 5.36414749e-02 -8.67988224e-02 1.02036481e-01 -1.01724821 0.02957619 38.50 4.86141275e-02 -6.25117462e-03 4.90143916e-02 -0.12788584 0.00777839 38.75 3.52334452e-02 -3.11588354e-02 4.70347604e-02 -0.72410330 0.00658615 39.00 4.43160282e-02 -6.83125251e-02 8.14279525e-02 -0.99531809 0.01939198 39.25 4.01131281e-02 -6.36561663e-02 7.52407506e-02 -1.00850002 0.01629151 39.50 3.73878096e-02 -1.62690075e-01 1.66930851e-01 -1.34490838 0.05908857 39.75 3.12536024e-02 -1.10920207e-01 1.15239229e-01 -1.29615027 0.03266640 40.00 1.00762540e-01 -7.35135169e-02 1.24729013e-01 -0.63029842 0.04277459 40.25 8.08583981e-02 -6.92351966e-02 1.06449955e-01 -0.70811272 0.03004913 40.50 9.03976201e-02 -4.76074756e-02 1.02167517e-01 -0.48473587 0.02610047 40.75 6.40292596e-02 -4.21290350e-02 7.66459501e-02 -0.58195441 0.01291718 41.00 5.97207092e-02 -4.06770537e-02 7.22577733e-02 -0.59794309 0.00877007 41.25 6.65357958e-02 -9.90792153e-02 1.19346986e-01 -0.97942649 0.02621869 41.50 2.37215374e-02 -1.89792891e-01 1.91269582e-01 -1.44645469 0.07241287 41.75 4.24746044e-02 -1.22950343e-01 1.30080279e-01 -1.23817046 0.03186605 42.00 1.06557246e-01 -8.15427493e-02 1.34177743e-01 -0.65318879 0.03010930 42.25 6.39277789e-02 -1.20805685e-01 1.36677630e-01 -1.08407926 0.03916137 42.50 8.53478985e-02 -1.21888143e-01 1.48798465e-01 -0.95992612 0.04973225 42.75 8.09054411e-02 -9.94747225e-02 1.28222115e-01 -0.88798205 0.02032591 43.00 1.09938432e-01 -1.26502890e-01 1.67599045e-01 -0.85534126 0.02577450 43.25 1.09845789e-01 -1.67532709e-01 2.00332988e-01 -0.99044708 0.04760841 43.50 6.29438331e-02 -2.15293538e-01 2.24306115e-01 -1.28636073 0.06225154 43.75 1.41893502e-02 -1.33994035e-01 1.34743234e-01 -1.46529413 0.01816226 44.00 4.50573565e-04 -1.93528685e-01 1.93529209e-01 -1.56846813 0.03146345 44.25 1.36659894e-01 -1.77269010e-01 2.23830803e-01 -0.91404148 0.03634774 44.50 2.77329570e-01 -1.86669567e-01 3.34301088e-01 -0.59244084 0.06051262 44.75 3.63802258e-01 -1.32058337e-01 3.87029052e-01 -0.34820427 0.08452190 45.00 3.68738562e-01 -8.07085240e-02 3.77467870e-01 -0.21547924 0.08876182 45.25 1.83476779e-01 -8.17170736e-02 2.00851708e-01 -0.41900614 0.03419242 45.50 1.24681983e-01 -3.65150245e-02 1.29918989e-01 -0.28489840 0.01540455 45.75 8.31073482e-02 -1.24395870e-01 1.49603355e-01 -0.98181059 0.01505025 46.00 1.01378887e-01 -1.68467433e-01 1.96618806e-01 -1.02907533 0.02522454 46.25 6.06527967e-02 -1.38463320e-01 1.51164985e-01 -1.15793077 0.01505491 46.50 2.19410968e-03 -1.45597102e-01 1.45613633e-01 -1.55572773 0.01185857 46.75 1.04002695e-01 -1.18936389e-01 1.57995017e-01 -0.85228378 0.00965144 47.00 1.58632687e-01 -1.13371551e-01 1.94980609e-01 -0.62051028 0.01371790 47.25 4.07830733e-03 -9.78593707e-02 9.79443159e-02 -1.52914524 0.00303598 47.50 8.09939501e-04 -1.10422038e-01 1.10425009e-01 -1.56346151 0.00330680 47.75 2.14189347e-01 5.58357836e-02 2.21347490e-01 0.25500885 0.00776012 48.00 2.78617424e-01 2.30462142e-02 2.79568949e-01 0.08252846 0.00997528 48.25 7.05223083e-01 1.18421744e-01 7.15096711e-01 0.16636883 0.05269835 48.50 7.24520824e-01 -1.63123314e-01 7.42657149e-01 -0.22145386 0.03631588 48.75 2.03206486e+00 -5.74537148e-01 2.11172454e+00 -0.27554365 0.12919672 49.00 2.00630246e+00 -6.20465681e-01 2.10005410e+00 -0.29992885 0.08918643 49.25 2.11573152e+00 -4.18073255e-01 2.15664210e+00 -0.19508895 0.02836666 49.50 4.05211251e+00 7.66627446e-01 4.12399484e+00 0.18698203 0.04961135 49.75 1.06342164e+01 2.00295132e+00 1.08212001e+01 0.18616865 0.07481057 50.00 5.80600795e+00 -2.28518563e+00 6.23953538e+00 -0.37496817 0.03006262 50.25 1.80145714e-01 -1.21138521e+00 1.22470674e+00 -1.42316773 0.00462589 50.50 2.75294669e-01 -1.35399107e+00 1.38169424e+00 -1.37020965 0.02280518 50.75 -1.01476913e+00 -1.86586746e-01 1.03178050e+00 -2.95975262 0.02457244 51.00 -3.06733226e-01 -2.49023258e-01 3.95092211e-01 -2.45966404 0.00794177 51.25 -4.38475263e-02 -8.01006402e-01 8.02205623e-01 -1.62548229 0.05630071 51.50 3.19797234e-02 -4.82889134e-01 4.83946917e-01 -1.50466708 0.02721844 51.75 -1.80265895e-01 -7.10653748e-01 7.33160653e-01 -1.81921866 0.04588965 52.00 -1.04712864e-01 -6.56396983e-01 6.64696761e-01 -1.72899010 0.05715626 52.25 -5.25231088e-02 -6.16731429e-01 6.18963919e-01 -1.65575499 0.03940173 52.50 -9.71123132e-02 -3.38259804e-01 3.51923992e-01 -1.85037098 0.02055306 52.75 -1.42913662e-01 -3.87018043e-01 4.12561851e-01 -1.92453288 0.03785686 53.00 -8.24743685e-02 -3.72932455e-01 3.81943238e-01 -1.78844419 0.04448242 53.25 6.32200463e-02 -4.12375945e-01 4.17193833e-01 -1.41867390 0.04571262 53.50 9.07263681e-02 -4.31011806e-01 4.40457093e-01 -1.36332889 0.05418131 53.75 2.91664124e-01 -4.55653780e-01 5.41006773e-01 -1.00141198 0.06735522 54.00 -5.78238314e-02 -4.37991389e-01 4.41791865e-01 -1.70205771 0.05265690 54.25 -2.69103416e-01 -7.85733811e-01 8.30538542e-01 -1.90076221 0.14508091 54.50 -5.61011428e-02 -4.18436627e-01 4.22180707e-01 -1.70407474 0.05906851 54.75 -6.93761404e-02 -2.35743090e-01 2.45739401e-01 -1.85700368 0.02542583 55.00 -6.09145767e-02 -3.57328703e-01 3.62483637e-01 -1.73964529 0.04500102 55.25 -3.62387060e-02 -5.94412143e-01 5.95515776e-01 -1.63168658 0.08296169 55.50 5.56196802e-02 -1.33241915e-01 1.44384753e-01 -1.17535173 0.00447671 55.75 -2.28596826e-01 -2.91839416e-01 3.70711146e-01 -2.23526897 0.02091478 56.00 -2.52673178e-01 -2.55771141e-01 3.59531100e-01 -2.35010154 0.02616449 56.25 -2.23085542e-01 -2.33819719e-01 3.23169955e-01 -2.33270559 0.02316807 56.50 -1.90622693e-01 -3.81623792e-01 4.26583790e-01 -2.03404723 0.06866454 56.75 -1.62684005e-01 -4.06077387e-01 4.37452774e-01 -1.95183979 0.06331680 57.00 -1.82069384e-01 -3.87368980e-01 4.28023349e-01 -2.01016982 0.04762296 57.25 -2.65483919e-01 -3.16117327e-01 4.12809734e-01 -2.26935481 0.03974299 57.50 -3.38012195e-01 -3.52666697e-01 4.88493647e-01 -2.33498014 0.05712909 57.75 -3.45536417e-01 -2.05381235e-01 4.01966252e-01 -2.60531297 0.04365427 58.00 -3.32760530e-01 -2.30717593e-01 4.04919965e-01 -2.53534763 0.06392596 58.25 -3.56809617e-01 -2.63115936e-01 4.43331816e-01 -2.50619622 0.09011290 58.50 -5.29386101e-01 -1.99092447e-01 5.65585932e-01 -2.78187394 0.17703704 58.75 -2.29475107e-01 -1.31938723e-01 2.64701061e-01 -2.61978937 0.04486155 59.00 1.12819138e-01 -4.14320956e-01 4.29406582e-01 -1.30494304 0.14416454 59.25 1.77769008e-01 -6.08255340e-01 6.33700544e-01 -1.28645503 0.25582082 59.50 2.95776750e-01 -7.22659792e-01 7.80846375e-01 -1.18230787 0.34630558 59.75 2.65972010e-01 -6.62749073e-01 7.14127050e-01 -1.18915572 0.26419235 60.00 3.49695092e-01 -6.85830905e-01 7.69838092e-01 -1.09927179 0.23976977 60.25 3.48092222e-01 -6.74042679e-01 7.58618302e-01 -1.09409554 0.22487799 60.50 4.37754291e-01 -6.20995149e-01 7.59778780e-01 -0.95677340 0.25492769 60.75 5.50283919e-01 -6.27845183e-01 8.34866436e-01 -0.85113756 0.23213202 61.00 8.18097198e-01 -7.40799104e-01 1.10366043e+00 -0.73585360 0.32035541 61.25 5.78538733e-01 -7.34957784e-01 9.35344862e-01 -0.90392597 0.21769266 61.50 5.19442970e-01 -8.15717850e-01 9.67065980e-01 -1.00376195 0.20970143 61.75 5.29731356e-01 -7.03663842e-01 8.80771317e-01 -0.92549364 0.18205002 62.00 6.72330988e-01 -8.78709333e-01 1.10641721e+00 -0.91767918 0.23328722 62.25 6.45988140e-01 -8.06767268e-01 1.03352509e+00 -0.89562146 0.21552857 62.50 7.59156665e-01 -8.76060427e-01 1.15922419e+00 -0.85676802 0.28770106 62.75 5.45066082e-01 -9.91873631e-01 1.13177309e+00 -1.06831266 0.23026553 63.00 6.03488744e-01 -1.44188430e+00 1.56308317e+00 -1.17440859 0.38417443 63.25 8.53678277e-01 -1.16838619e+00 1.44702898e+00 -0.93979639 0.33550649 63.50 1.13882218e+00 -1.14316889e+00 1.61361429e+00 -0.78730295 0.44848962 63.75 1.34696552e+00 -9.83728118e-01 1.66794398e+00 -0.63079241 0.35767792 64.00 1.61247038e+00 -9.47007828e-01 1.86999587e+00 -0.53103076 0.37644260 64.25 1.61211087e+00 -1.17116802e+00 1.99262038e+00 -0.62827830 0.35628631 64.50 1.75908629e+00 -1.14697854e+00 2.09998674e+00 -0.57780156 0.37912176 64.75 1.65679669e+00 -7.61561864e-01 1.82344502e+00 -0.43085743 0.21104513 65.00 1.81138894e+00 -8.85690951e-01 2.01632794e+00 -0.45477409 0.19778581 65.25 1.33759762e+00 -1.38378098e+00 1.92458234e+00 -0.80236711 0.14446533 65.50 2.14314397e+00 -1.56956458e+00 2.65642599e+00 -0.63211913 0.22110896 65.75 2.81809920e+00 -1.25322340e+00 3.08419390e+00 -0.41844206 0.24983475 66.00 3.74164737e+00 -1.33742111e+00 3.97348968e+00 -0.34328903 0.29543293 66.25 3.74166572e+00 -2.40679738e+00 4.44890278e+00 -0.57160991 0.34209145 66.50 4.34735147e+00 -3.39253939e+00 5.51441641e+00 -0.66265583 0.43825208 66.75 5.64567496e+00 -4.25102768e+00 7.06716931e+00 -0.64539963 0.58000691 67.00 5.94110365e+00 -4.19584984e+00 7.27336707e+00 -0.61490216 0.54360676 67.25 6.42579877e+00 -2.93972305e+00 7.06631880e+00 -0.42906312 0.30959472 67.50 7.26299523e+00 -4.54120101e+00 8.56583950e+00 -0.55878038 0.34039028 67.75 1.41010626e+01 -7.89141313e+00 1.61590336e+01 -0.51020852 0.49703054 68.00 1.91484106e+01 -1.03285609e+01 2.17563967e+01 -0.49466489 0.51243982 68.25 3.44436454e+01 -2.94295411e+01 4.53041123e+01 -0.70705789 0.45419345 68.50 2.05147350e+01 -4.73807772e+01 5.16313122e+01 -1.16218946 0.32519786 68.75 -3.77093933e+01 -9.19155392e+00 3.88134384e+01 -2.90250771 0.32022702 69.00 -3.38068483e+01 -1.40927094e+00 3.38362090e+01 -3.09993081 0.50298070 69.25 -2.12926677e+01 4.19586361e+00 2.17021421e+01 2.94702875 0.64811435 69.50 -1.67564685e+01 4.66245863e+00 1.73930376e+01 2.87020905 0.68868069 69.75 -1.35502287e+01 3.04387843e+00 1.38879046e+01 2.92062405 0.77760396 70.00 -1.24936495e+01 1.92091535e+00 1.26404586e+01 2.98903595 0.80680058 70.25 -1.14672506e+01 1.32750870e+00 1.15438346e+01 3.02634047 0.84642792 70.50 -1.01825699e+01 1.60850584e+00 1.03088322e+01 2.98492067 0.82707324 70.75 -8.96120885e+00 1.61805682e+00 9.10611728e+00 2.96295508 0.89849377 71.00 -8.56947731e+00 1.74816591e+00 8.74597196e+00 2.94035475 0.86719964 71.25 -7.84289283e+00 1.86657482e+00 8.06195197e+00 2.90794367 0.79850702 71.50 -5.96006759e+00 1.57362705e+00 6.16430919e+00 2.88345500 0.66853274 71.75 -4.64521416e+00 1.27524195e+00 4.81707968e+00 2.87366519 0.67314970 72.00 -4.22944131e+00 1.17287432e+00 4.38905547e+00 2.87107838 0.62215893 72.25 -4.56211012e+00 1.38447632e+00 4.76755949e+00 2.84695286 0.78058770 72.50 -4.50385908e+00 9.30027091e-01 4.59887997e+00 2.93795920 0.80277899 72.75 -4.57463456e+00 5.53291297e-01 4.60797272e+00 3.02122964 0.85006412 73.00 -4.37112678e+00 5.06625329e-01 4.40038846e+00 3.02620482 0.86131812 73.25 -4.36285855e+00 7.57098716e-01 4.42806201e+00 2.96977102 0.92451252 73.50 -4.23970299e+00 5.90852867e-01 4.28067618e+00 3.00312265 0.92067355 73.75 -4.38089732e+00 4.33062049e-01 4.40224989e+00 3.04306040 0.94541490 74.00 -4.36926313e+00 3.81264414e-01 4.38586626e+00 3.05455255 0.91050854 74.25 -4.51189759e+00 3.97886072e-01 4.52940760e+00 3.05363422 0.92082123 74.50 -4.47072542e+00 4.45895002e-01 4.49290642e+00 3.04218479 0.89179342 74.75 -4.64693157e+00 3.38402763e-01 4.65923700e+00 3.06889813 0.89906578 75.00 -4.23164239e+00 4.50903116e-01 4.25559760e+00 3.03543809 0.76220674 75.25 -4.01713298e+00 8.33881177e-01 4.10276921e+00 2.93691824 0.72671550 75.50 -3.65680054e+00 1.05231802e+00 3.80520215e+00 2.86139333 0.57386408 75.75 -3.95249358e+00 1.52872014e+00 4.23782854e+00 2.77254009 0.60103848 76.00 -2.88111951e+00 1.96050699e+00 3.48488698e+00 2.54409667 0.47059076 76.25 -2.41127263e+00 1.72476862e+00 2.96463530e+00 2.52067590 0.31253633 76.50 -1.26351267e+00 9.64916844e-01 1.58982036e+00 2.48939494 0.16515699 76.75 -1.40033206e+00 1.51401079e+00 2.06231873e+00 2.31720761 0.34502406 77.00 -2.39715529e+00 1.83854374e+00 3.02102574e+00 2.48731956 0.63255248 77.25 -3.06264260e+00 1.97512602e+00 3.64429725e+00 2.56880462 0.72141540 77.50 -4.26379249e+00 2.64656665e+00 5.01839032e+00 2.58608626 0.68564652 77.75 -4.89198956e+00 3.91081078e+00 6.26306656e+00 2.46719843 0.62116797 78.00 -5.52938156e+00 1.00769848e+01 1.14943326e+01 2.07265159 0.58281113 78.25 -3.01294269e+00 1.44600791e+01 1.47706368e+01 1.77621996 0.63831674 78.50 6.12869453e+00 1.41825195e+01 1.54500730e+01 1.16290190 0.56041507 78.75 8.47449351e+00 9.19933900e+00 1.25077927e+01 0.82638755 0.52153104 79.00 8.51690708e+00 1.46335040e+00 8.64170704e+00 0.17015570 0.47155106 79.25 7.31584319e+00 -1.90401067e-01 7.31832045e+00 -0.02601998 0.53516749 79.50 5.30157134e+00 -1.86059962e-01 5.30483525e+00 -0.03508085 0.48272780 79.75 4.26968007e+00 -7.76392601e-01 4.33969508e+00 -0.17987325 0.36453487 80.00 3.15891030e+00 -1.74664731e+00 3.60963864e+00 -0.50508778 0.45778722 80.25 2.59165664e+00 -1.81123735e+00 3.16184517e+00 -0.60996880 0.42086017 80.50 2.35400323e+00 -2.47937106e+00 3.41886123e+00 -0.81133030 0.43834557 80.75 2.18066045e+00 -1.95736020e+00 2.93027967e+00 -0.73148740 0.35053990 81.00 1.80270741e+00 -2.39141668e+00 2.99476672e+00 -0.92485231 0.38960754 81.25 6.24732411e-01 -2.37042812e+00 2.45137105e+00 -1.31310354 0.33186638 81.50 -2.09040866e-01 -2.14087857e+00 2.15106000e+00 -1.66813034 0.30527344 81.75 -3.61973717e-01 -1.89345190e+00 1.92774092e+00 -1.75968855 0.27765576 82.00 -4.53904067e-01 -1.77998624e+00 1.83694854e+00 -1.82047930 0.24175665 82.25 -5.07278467e-01 -1.12627551e+00 1.23524410e+00 -1.99398578 0.14136560 82.50 -9.49157240e-01 -1.01718053e+00 1.39124250e+00 -2.32161438 0.15618236 82.75 -7.17423099e-01 -7.75813831e-01 1.05668491e+00 -2.31711094 0.12218880 83.00 -8.47245155e-01 -7.56648613e-01 1.13593199e+00 -2.41261991 0.15340467 83.25 -8.45829328e-01 -4.54022490e-01 9.59981080e-01 -2.64895741 0.12296640 83.50 -1.09023215e+00 -4.66013736e-01 1.18565381e+00 -2.73765332 0.18127550 83.75 -6.36688570e-01 -3.09552076e-01 7.07951145e-01 -2.68905337 0.09017380 84.00 -8.23289212e-01 -4.31283323e-01 9.29414026e-01 -2.65904448 0.16736336 84.25 -5.90958216e-01 -1.47942343e-01 6.09195002e-01 -2.89629105 0.08273001 84.50 -4.01379305e-01 -1.78073665e-01 4.39107705e-01 -2.72402831 0.04582047 84.75 -5.00007793e-01 -3.18167192e-01 5.92653487e-01 -2.57489132 0.08560428 85.00 -6.96944446e-01 -3.36298420e-01 7.73839898e-01 -2.69201635 0.13799473 85.25 -8.88319796e-01 -3.96905875e-01 9.72957519e-01 -2.72139873 0.20640708 85.50 -1.09290393e+00 -3.91009672e-01 1.16074440e+00 -2.79801146 0.31245689 85.75 -8.19724753e-01 -2.83074552e-01 8.67225387e-01 -2.80908532 0.23540594 86.00 -9.46447723e-01 -2.11965641e-01 9.69893151e-01 -2.92126911 0.28110365 86.25 -8.74962091e-01 -1.22384868e-01 8.83479890e-01 -3.00261982 0.24582809 86.50 -8.44661887e-01 -9.09465437e-02 8.49543982e-01 -3.03433375 0.27624854 86.75 -8.52227496e-01 -1.29613718e-01 8.62027506e-01 -2.99066112 0.26046292 87.00 -9.35063396e-01 -1.03181258e-01 9.40739032e-01 -3.03169048 0.31169611 87.25 -8.49348967e-01 -2.43666240e-01 8.83610154e-01 -2.86221014 0.23156289 87.50 -8.94513511e-01 -1.60033717e-01 9.08716244e-01 -2.96455971 0.24224963 87.75 -5.02989498e-01 -2.57454114e-01 5.65049605e-01 -2.66851172 0.09529220 88.00 -3.20420320e-01 -2.50001656e-01 4.06411133e-01 -2.47902316 0.05085561 88.25 -3.76072671e-01 -2.29910691e-01 4.40782917e-01 -2.59287192 0.06064456 88.50 -4.44793385e-01 -1.99715807e-01 4.87573132e-01 -2.71956395 0.07646410 88.75 -3.57828393e-01 -2.91624245e-01 4.61612239e-01 -2.45778196 0.06550503 89.00 -4.50258104e-01 -3.47937518e-01 5.69028010e-01 -2.48368903 0.10157459 89.25 -5.39966528e-01 -2.38242940e-01 5.90189419e-01 -2.72606581 0.09703742 89.50 -8.07129762e-01 -2.91933335e-01 8.58302701e-01 -2.79453896 0.17634209 89.75 -1.35461877e+00 -1.77151110e-01 1.36615318e+00 -3.01155499 0.43185429 90.00 -1.33123010e+00 -1.54337703e-01 1.34014690e+00 -3.02617179 0.50379431 90.25 -1.25745159e+00 -4.75692722e-02 1.25835103e+00 -3.10378078 0.55394061 90.50 -1.07936938e+00 2.86639483e-02 1.07974992e+00 3.11504269 0.51778929 90.75 -8.80759782e-01 -9.03904173e-02 8.85385917e-01 -3.03932293 0.50568008 91.00 -1.00413924e+00 -1.40619522e-01 1.01393760e+00 -3.00245761 0.49970649 91.25 -1.12608378e+00 -1.83276676e-01 1.14090097e+00 -2.98025153 0.66773825 91.50 -1.09076431e+00 -2.76751790e-02 1.09111535e+00 -3.11622581 0.59553223 91.75 -1.09774136e+00 2.61923542e-01 1.12855662e+00 2.90736973 0.71899985 92.00 -9.60220611e-01 2.85284850e-01 1.00170408e+00 2.85279536 0.70208518 92.25 -8.88763293e-01 1.97155800e-01 9.10368387e-01 2.92329596 0.74269141 92.50 -8.55510812e-01 1.05851593e-01 8.62034402e-01 3.01848919 0.58875363 92.75 -7.88081947e-01 7.29320103e-02 7.91449451e-01 3.04931181 0.51571070 93.00 -7.66740432e-01 4.54768830e-02 7.68087910e-01 3.08235009 0.39477832 93.25 -7.36605327e-01 1.08229491e-01 7.44513956e-01 2.99570640 0.44005314 93.50 -5.10273204e-01 1.50415589e-01 5.31980819e-01 2.85493665 0.23701129 93.75 -3.25011122e-01 2.12720522e-01 3.88435644e-01 2.56205889 0.17500697 94.00 -3.62844730e-01 2.82285398e-02 3.63941133e-01 3.06395119 0.15241365 94.25 -4.50109185e-01 5.12565084e-02 4.53018221e-01 3.02820537 0.29584827 94.50 -4.22289486e-01 1.69435409e-01 4.55012931e-01 2.76002598 0.24658598 94.75 -4.07045389e-01 2.41936822e-01 4.73518083e-01 2.60532087 0.31113092 95.00 -3.08883453e-01 4.74235684e-01 5.65958012e-01 2.14810525 0.27037605 95.25 -3.56184329e-01 7.03314588e-01 7.88364564e-01 2.03958004 0.44175261 95.50 -5.96446264e-02 8.21327205e-01 8.23490048e-01 1.64328888 0.35214574 95.75 5.02934303e-01 1.09741006e+00 1.20716683e+00 1.14106817 0.50598033 96.00 9.15934614e-01 7.10488080e-01 1.15919348e+00 0.65974561 0.54492591 96.25 1.08649885e+00 4.90486712e-01 1.19208094e+00 0.42404900 0.59030628 96.50 9.96508071e-01 4.71321969e-01 1.10234874e+00 0.44179364 0.47415928 96.75 9.60419279e-01 6.49485804e-01 1.15941235e+00 0.59460953 0.54003727 97.00 1.52784567e+00 5.85622304e-01 1.63623527e+00 0.36602692 0.68863459 97.25 2.01314401e+00 4.56510315e-01 2.06425543e+00 0.22299362 0.76835188 97.50 2.95462470e+00 6.42940871e-02 2.95532416e+00 0.02175706 0.86386040 97.75 3.38871177e+00 -2.71703310e-01 3.39958676e+00 -0.08000778 0.88464322 98.00 3.80415990e+00 -1.67529048e+00 4.15670912e+00 -0.41482840 0.88434064 98.25 3.52934349e+00 -2.61537449e+00 4.39277238e+00 -0.63774014 0.83709491 98.50 1.92217452e+00 -3.34960293e+00 3.86194182e+00 -1.04982564 0.82177781 98.75 1.73510480e+00 -2.68857833e+00 3.19985033e+00 -0.99768887 0.82578110 99.00 2.38915236e+00 -2.27100083e+00 3.29628484e+00 -0.76005002 0.86339507 99.25 3.01431686e+00 -2.52122346e+00 3.92971676e+00 -0.69655492 0.84738120 99.50 4.28629135e+00 -3.90017101e+00 5.79513826e+00 -0.73826738 0.90576363 99.75 4.21176938e+00 -5.03003149e+00 6.56050441e+00 -0.87370714 0.85099482 100.00 3.35809731e+00 -8.79731001e+00 9.41644736e+00 -1.20614838 0.90362059 100.25 1.59682063e+00 -1.05266212e+01 1.06470461e+01 -1.42025050 0.89231028 100.50 -3.16071598e+00 -1.06062704e+01 1.10672082e+01 -1.86042136 0.92949345 100.75 -4.31875632e+00 -8.83380190e+00 9.83299101e+00 -2.02551640 0.90311450 101.00 -5.83340468e+00 -5.55954930e+00 8.05836203e+00 -2.38022712 0.94612112 101.25 -5.72476029e+00 -4.59758675e+00 7.34238955e+00 -2.46496095 0.93926030 101.50 -5.65447187e+00 -3.39237431e+00 6.59403181e+00 -2.60121331 0.96656464 101.75 -5.64176499e+00 -2.91820663e+00 6.35180621e+00 -2.66423995 0.96691877 102.00 -5.72374548e+00 -2.23998997e+00 6.14644754e+00 -2.76856501 0.96370497 102.25 -5.47839894e+00 -1.56603029e+00 5.69783343e+00 -2.86316247 0.95915235 102.50 -4.95080232e+00 -9.65127548e-01 5.04399790e+00 -2.94906365 0.97580071 102.75 -4.49051104e+00 -6.80450159e-01 4.54177298e+00 -2.99120605 0.97005170 103.00 -4.10102905e+00 -6.31878325e-01 4.14942279e+00 -2.98871685 0.98558434 103.25 -3.99352593e+00 -5.13969788e-01 4.02646425e+00 -3.01359552 0.98437818 103.50 -3.90259871e+00 -3.04653839e-01 3.91447195e+00 -3.06368630 0.99027497 103.75 -3.76834006e+00 -1.71873910e-01 3.77225761e+00 -3.09601426 0.98613458 104.00 -3.64667652e+00 -4.34398742e-02 3.64693525e+00 -3.12968104 0.99091116 104.25 -3.49486604e+00 6.43452551e-02 3.49545833e+00 3.12318337 0.98949067 104.50 -3.43206973e+00 1.51246003e-01 3.43540070e+00 3.09755269 0.99011647 104.75 -3.33246445e+00 4.20659797e-01 3.35890964e+00 3.01602594 0.98327914 105.00 -3.13766586e+00 6.34166360e-01 3.20111137e+00 2.94216518 0.98560743 105.25 -2.78425380e+00 6.81400253e-01 2.86642208e+00 2.90157678 0.98065291 105.50 -2.56865415e+00 7.15196749e-01 2.66636279e+00 2.87003810 0.98822405 105.75 -2.30842213e+00 5.83825518e-01 2.38110583e+00 2.89387604 0.98652137 106.00 -2.18809199e+00 4.73069340e-01 2.23864717e+00 2.92866811 0.98881988 106.25 -2.22981546e+00 2.80599954e-01 2.24740146e+00 3.01641068 0.98644673 106.50 -2.28540045e+00 1.28779336e-01 2.28902585e+00 3.08530348 0.99133299 106.75 -2.48716701e+00 1.40943134e-01 2.49115730e+00 3.08498505 0.98566009 107.00 -2.66571609e+00 2.42871317e-01 2.67675713e+00 3.05073428 0.98029138 107.25 -2.64615793e+00 5.68965039e-01 2.70663500e+00 2.92980165 0.97525088 107.50 -2.62580530e+00 6.63942372e-01 2.70844475e+00 2.89393076 0.98603918 107.75 -2.72596495e+00 7.24377886e-01 2.82056878e+00 2.88186247 0.98164414 108.00 -2.87719662e+00 8.85377059e-01 3.01034100e+00 2.84306648 0.96768042 108.25 -3.00813171e+00 1.74067768e+00 3.47545899e+00 2.61701408 0.92822206 108.50 -2.61291978e+00 2.28401869e+00 3.47045979e+00 2.42325840 0.87061816 108.75 -1.18626202e+00 2.19634839e+00 2.49622992e+00 2.06601203 0.84038392 109.00 -8.57845040e-01 1.96479268e+00 2.14390027e+00 1.98245819 0.89377533 109.25 -8.73607449e-01 1.61518653e+00 1.83630540e+00 2.06660365 0.93171995 109.50 -7.86684883e-01 1.53000352e+00 1.72040224e+00 2.04571710 0.93926032 109.75 -5.63611793e-01 1.20572551e+00 1.33095164e+00 2.00806341 0.85148436 110.00 -7.10074654e-01 9.52011889e-01 1.18765847e+00 2.21164734 0.68053120 110.25 -7.32945557e-01 1.40016519e+00 1.58040240e+00 2.05304377 0.56910332 110.50 -1.76653192e-01 1.25418973e+00 1.26656948e+00 1.71072628 0.58369049 110.75 -1.05402796e-01 8.02315968e-01 8.09209900e-01 1.70142145 0.79141839 111.00 -1.55178421e-01 7.19226570e-01 7.35776597e-01 1.78329627 0.74451271 111.25 -2.40109077e-01 5.02285379e-01 5.56725220e-01 2.01671655 0.54220814 111.50 -3.50336330e-01 4.58591011e-01 5.77097270e-01 2.22315994 0.55488760 111.75 -2.45630286e-01 4.68051324e-01 5.28588952e-01 2.05408142 0.50178583 112.00 -3.18995572e-01 3.65873607e-01 4.85408767e-01 2.28785293 0.45417561 112.25 -2.41699328e-01 1.43168664e-01 2.80919618e-01 2.60682306 0.29652991 112.50 -2.50602101e-01 1.06496660e-02 2.50828285e-01 3.09912189 0.22083005 112.75 -2.01418554e-01 -3.19592774e-01 3.77768415e-01 -2.13315129 0.34762996 113.00 -5.77903522e-01 -4.57774668e-01 7.37244957e-01 -2.47166900 0.65412169 113.25 -9.80168938e-01 -3.57300668e-01 1.04326167e+00 -2.79203289 0.89390275 113.50 -1.11806173e+00 -1.93509456e-01 1.13468407e+00 -2.97021459 0.93471013 113.75 -1.17383702e+00 -6.23667067e-02 1.17549265e+00 -3.08851193 0.95702943 114.00 -1.12416348e+00 1.15945016e-01 1.13012689e+00 3.03881713 0.95082114 114.25 -1.09123457e+00 1.79266271e-01 1.10586133e+00 2.97876859 0.97974170 114.50 -1.06830758e+00 1.86854238e-01 1.08452551e+00 2.96843744 0.96811324 114.75 -1.03792075e+00 1.88277349e-01 1.05485916e+00 2.96214536 0.96071201 115.00 -1.05587638e+00 2.01331532e-01 1.07489967e+00 2.95317720 0.93919660 115.25 -1.09612839e+00 1.97622739e-01 1.11380079e+00 2.96321728 0.94717266 115.50 -1.12261956e+00 2.68352745e-01 1.15424775e+00 2.90695410 0.93810575 115.75 -1.14609750e+00 3.04936200e-01 1.18597030e+00 2.88155226 0.94012480 116.00 -1.17167421e+00 3.14894626e-01 1.21325145e+00 2.87904054 0.92951798 116.25 -1.21878516e+00 2.93065815e-01 1.25352496e+00 2.90561530 0.94459070 116.50 -1.25146800e+00 3.71930205e-01 1.30556664e+00 2.85271111 0.93374995 116.75 -1.27142091e+00 4.78981472e-01 1.35865168e+00 2.78130677 0.94832331 117.00 -1.21237215e+00 6.06459738e-01 1.35559568e+00 2.67776448 0.92528413 117.25 -1.24527070e+00 5.57122048e-01 1.36421556e+00 2.72091106 0.92010031 117.50 -1.53371473e+00 4.72730769e-01 1.60491596e+00 2.84260625 0.89529753 117.75 -1.83420998e+00 6.54863074e-01 1.94760671e+00 2.79867118 0.86499930 118.00 -2.59994982e+00 1.31999844e+00 2.91584206e+00 2.67180284 0.89797679 118.25 -2.96976676e+00 1.99701516e+00 3.57876853e+00 2.54959793 0.87906392 118.50 -1.99409618e+00 4.31880071e+00 4.75693800e+00 2.00335748 0.83432664 118.75 -6.13157603e-01 4.80586229e+00 4.84481936e+00 1.69769608 0.81608128 119.00 2.22462217e+00 2.64552831e+00 3.45655375e+00 0.87160964 0.76606182 119.25 2.36331590e+00 1.72911205e+00 2.92832555e+00 0.63165109 0.84315987 119.50 2.03625005e+00 7.15088834e-01 2.15816272e+00 0.33772502 0.87686010 119.75 1.80961949e+00 4.58455113e-01 1.86678970e+00 0.24812289 0.91852974 120.00 1.61288909e+00 2.69003101e-01 1.63516785e+00 0.16526224 0.92262571 120.25 1.49646439e+00 1.33882461e-01 1.50244140e+00 0.08922829 0.90145769 120.50 1.36767157e+00 -3.62507304e-02 1.36815191e+00 -0.02649923 0.92348253 120.75 1.31576976e+00 -1.87112497e-01 1.32900758e+00 -0.14126047 0.90114251 121.00 1.13559372e+00 -4.94131996e-01 1.23844238e+00 -0.41042028 0.90471226 121.25 9.66212347e-01 -5.40443082e-01 1.10708854e+00 -0.50998722 0.87850500 121.50 8.31970670e-01 -5.38301747e-01 9.90930859e-01 -0.57427754 0.91754439 121.75 9.36144998e-01 -5.18418848e-01 1.07010540e+00 -0.50574107 0.90956448 122.00 1.07445937e+00 -7.27370297e-01 1.29750934e+00 -0.59509767 0.90218409 122.25 1.04278896e+00 -1.02748367e+00 1.46394382e+00 -0.77800542 0.83296518 122.50 8.06414262e-01 -1.74132903e+00 1.91899212e+00 -1.13709974 0.87140126 122.75 3.13375455e-01 -1.93703027e+00 1.96221570e+00 -1.41040462 0.78684715 123.00 -8.92381213e-01 -2.66696257e+00 2.81230041e+00 -1.89369169 0.86593412 123.25 -1.71779774e+00 -2.22863635e+00 2.81383174e+00 -2.22746718 0.85090401 123.50 -2.10807254e+00 -6.80593048e-01 2.21521482e+00 -2.82930580 0.76541725 123.75 -1.36518757e+00 -2.74519907e-01 1.39251509e+00 -2.94315322 0.73188333 124.00 -8.83499751e-01 -1.75568206e-01 9.00775225e-01 -2.94542911 0.84204640 124.25 -8.11191773e-01 -1.78932456e-01 8.30691830e-01 -2.92448946 0.85225239 124.50 -7.83738210e-01 -2.24397611e-01 8.15229949e-01 -2.86273581 0.94081272 124.75 -8.14791052e-01 -1.86955123e-01 8.35964519e-01 -2.91604516 0.94799120 125.00 -8.00866402e-01 -1.13254034e-01 8.08834636e-01 -3.00110978 0.95884762 125.25 -7.26268321e-01 -6.37242812e-02 7.29058611e-01 -3.05407472 0.94309949 125.50 -6.79186104e-01 6.76562418e-03 6.79219801e-01 3.13163161 0.96227205 125.75 -6.31538155e-01 2.73803501e-02 6.32131415e-01 3.09826477 0.95987227 126.00 -6.01060927e-01 3.37530721e-02 6.02007897e-01 3.08549575 0.96400178 126.25 -5.39938182e-01 5.77710889e-02 5.43020017e-01 3.03500242 0.95185448 126.50 -4.95888286e-01 7.09749407e-02 5.00941748e-01 2.99943127 0.96237816 126.75 -4.47188630e-01 9.22012117e-02 4.56594716e-01 2.93826221 0.94287068 127.00 -4.15720085e-01 6.16296643e-02 4.20263494e-01 2.99441661 0.93841975 127.25 -4.21264511e-01 1.13006813e-02 4.21416058e-01 3.11477347 0.92480468 127.50 -4.32263766e-01 1.20975587e-02 4.32433017e-01 3.11361344 0.93251575 127.75 -4.11887555e-01 6.92020112e-02 4.17660479e-01 2.97513539 0.88104419 128.00 -3.70530259e-01 1.11425490e-01 3.86921585e-01 2.84947635 0.85485753 128.25 -2.42923842e-01 1.19773923e-01 2.70846425e-01 2.68351942 0.71411383 128.50 -1.53721459e-01 9.66140996e-02 1.81561480e-01 2.58047968 0.53939871 128.75 -1.13831251e-02 6.61085586e-02 6.70814211e-02 1.74131262 0.08385987 129.00 6.79900740e-02 -5.08661070e-02 8.49117837e-02 -0.64230977 0.06918131 129.25 -8.09083124e-02 -4.00671208e-01 4.08758574e-01 -1.77004882 0.71821837 129.50 -1.86706131e-01 -4.64712340e-01 5.00816072e-01 -1.95282514 0.85438192 129.75 -3.55277860e-01 -5.03742477e-01 6.16424237e-01 -2.18505497 0.93049064 130.00 -4.37440369e-01 -5.00173427e-01 6.64475382e-01 -2.28938692 0.95816239 130.25 -5.68448937e-01 -4.67063327e-01 7.35718931e-01 -2.45379208 0.97104680 130.50 -6.15758622e-01 -3.91535169e-01 7.29697519e-01 -2.57522327 0.96172321 130.75 -7.19249544e-01 -2.04739762e-01 7.47822356e-01 -2.86427031 0.97324933 131.00 -6.97945304e-01 -1.18867750e-01 7.07995190e-01 -2.97290026 0.96577695 131.25 -5.46146162e-01 -1.65686468e-03 5.46148675e-01 -3.13855892 0.96597524 131.50 -4.88331824e-01 -2.50344115e-02 4.88973100e-01 -3.09037233 0.97571551 131.75 -4.38240062e-01 -6.92534954e-02 4.43678260e-01 -2.98486233 0.98528397 132.00 -4.37103911e-01 -8.90866929e-02 4.46089978e-01 -2.94053513 0.97943584 132.25 -4.66928056e-01 -1.16639310e-01 4.81275948e-01 -2.89680086 0.97926874 132.50 -4.81332167e-01 -8.95701530e-02 4.89595208e-01 -2.95760907 0.97430410 132.75 -4.47492882e-01 -6.53567087e-02 4.52240399e-01 -2.99656719 0.97504816 133.00 -4.39052745e-01 -6.36656212e-02 4.43644705e-01 -2.99758960 0.97915592 133.25 -4.38848344e-01 -4.71354665e-02 4.41372429e-01 -3.03459566 0.98541346 133.50 -4.27981302e-01 -4.66966139e-02 4.30521276e-01 -3.03291356 0.97989907 133.75 -4.19359567e-01 -4.50674849e-02 4.21774258e-01 -3.03453613 0.97934851 134.00 -3.97102423e-01 -2.53885256e-02 3.97913196e-01 -3.07774510 0.94105334 134.25 -3.20916058e-01 1.24966337e-02 3.21159278e-01 3.10267181 0.91471188 134.50 -2.50494160e-01 -2.54542045e-02 2.51784116e-01 -3.04032430 0.85734324 134.75 -1.93283950e-01 -6.54754948e-02 2.04072844e-01 -2.81497246 0.86449166 135.00 -1.57360931e-01 -1.39381116e-01 2.10213125e-01 -2.41671123 0.78452196 135.25 -1.47486083e-01 -2.46686660e-01 2.87413383e-01 -2.10964677 0.86875798 135.50 -2.12448750e-01 -3.46028187e-01 4.06041842e-01 -2.12142004 0.92402635 135.75 -2.92609337e-01 -4.11230609e-01 5.04708666e-01 -2.18922907 0.96780944 136.00 -3.41983510e-01 -4.15181221e-01 5.37892338e-01 -2.25982054 0.98228665 136.25 -3.70683077e-01 -4.27391612e-01 5.65746881e-01 -2.28525704 0.98103458 136.50 -4.42960283e-01 -4.99147154e-01 6.67354249e-01 -2.29662549 0.96842619 136.75 -5.26098096e-01 -5.39117186e-01 7.53277205e-01 -2.34397307 0.96733880 137.00 -7.25625033e-01 -4.63395345e-01 8.60968603e-01 -2.57326232 0.95387749 137.25 -8.65610118e-01 -3.50788405e-01 9.33987892e-01 -2.75656872 0.94929494 137.50 -8.79601292e-01 -1.29574900e-01 8.89093970e-01 -2.99533362 0.92559219 137.75 -7.87016067e-01 4.80255668e-03 7.87030720e-01 3.13549049 0.90754233 138.00 -5.54873140e-01 2.62312381e-02 5.55492825e-01 3.09435353 0.80736661 138.25 -4.36609989e-01 -2.89854563e-02 4.37571068e-01 -3.07530240 0.79527998 138.50 -4.36902809e-01 -1.61802223e-01 4.65901303e-01 -2.78691444 0.83145256 138.75 -4.58916143e-01 -2.21730755e-01 5.09674949e-01 -2.69150611 0.89511272 139.00 -5.51507167e-01 -2.31200285e-01 5.98008133e-01 -2.74463182 0.93777538 139.25 -5.69454247e-01 -2.22010583e-01 6.11201144e-01 -2.76985330 0.96175159 139.50 -6.07234230e-01 -2.18479063e-01 6.45342166e-01 -2.79621970 0.96349216 139.75 -6.26729787e-01 -2.07772016e-01 6.60272245e-01 -2.82147706 0.96854637 140.00 -6.48154319e-01 -1.63353400e-01 6.68422288e-01 -2.89470567 0.96580584 140.25 -6.56012167e-01 -1.40524720e-01 6.70894299e-01 -2.93057120 0.97234993 140.50 -6.84012882e-01 -1.11973477e-01 6.93117365e-01 -2.97933103 0.98448092 140.75 -6.94472954e-01 -1.03627917e-01 7.02161968e-01 -2.99346751 0.98399108 141.00 -7.38098443e-01 -5.07285444e-02 7.39839643e-01 -3.07297187 0.98861964 141.25 -7.35442627e-01 -2.07587207e-02 7.35735538e-01 -3.11337399 0.99144120 141.50 -7.02856840e-01 2.12343583e-02 7.03177528e-01 3.11139034 0.98806602 141.75 -6.76914440e-01 2.66025595e-02 6.77436975e-01 3.10231313 0.98387153 142.00 -6.24689630e-01 2.69257149e-02 6.25269644e-01 3.09851677 0.98171228 142.25 -6.21472260e-01 1.69284770e-02 6.21702777e-01 3.11436008 0.98322007 142.50 -6.27526995e-01 -2.03129489e-03 6.27530283e-01 -3.13835568 0.98491992 142.75 -6.40593320e-01 -3.04246070e-03 6.40600545e-01 -3.13684325 0.97901768 143.00 -6.57297159e-01 4.00041385e-02 6.58513391e-01 3.08080606 0.97688205 143.25 -6.59934607e-01 5.01357167e-02 6.61836291e-01 3.06576757 0.97829041 143.50 -6.61010564e-01 6.58160425e-02 6.64279096e-01 3.04235093 0.98258691 143.75 -6.73538909e-01 8.30882946e-02 6.78644478e-01 3.01885197 0.98209801 144.00 -6.83153235e-01 9.08112715e-02 6.89162557e-01 3.00943784 0.98186522 144.25 -6.86859129e-01 9.97304556e-02 6.94061688e-01 2.99740248 0.97222442 144.50 -6.83758286e-01 1.26999153e-01 6.95452499e-01 2.95794846 0.96881081 144.75 -7.05231873e-01 1.55287590e-01 7.22126187e-01 2.92485763 0.95537814 145.00 -7.69721755e-01 2.00766974e-01 7.95474046e-01 2.88644676 0.96412552 145.25 -7.92006342e-01 2.67432627e-01 8.35939146e-01 2.81594890 0.95614870 145.50 -8.36835514e-01 2.86550787e-01 8.84536620e-01 2.81168483 0.95896718 145.75 -8.67340646e-01 3.83840747e-01 9.48479581e-01 2.72495222 0.92319596 146.00 -8.67517715e-01 6.10913105e-01 1.06103808e+00 2.52804796 0.92142561 146.25 -7.69887882e-01 8.13598484e-01 1.12012046e+00 2.32859747 0.89994312 146.50 -5.59769470e-01 9.38814812e-01 1.09303024e+00 2.10845481 0.90071769 146.75 -2.85759597e-01 1.04288050e+00 1.08132247e+00 1.83824183 0.87852196 147.00 5.49828435e-03 1.02072107e+00 1.02073588e+00 1.56540971 0.85350162 147.25 2.54637905e-01 7.35313414e-01 7.78155691e-01 1.23742289 0.75780195 147.50 3.58459664e-01 4.84539024e-01 6.02719999e-01 0.93385832 0.71066359 147.75 2.84512897e-01 2.28707184e-01 3.65040497e-01 0.67708728 0.56952319 148.00 2.00119391e-01 1.39096715e-01 2.43712262e-01 0.60740866 0.49828877 148.25 1.03720928e-01 5.33017330e-02 1.16615203e-01 0.47470223 0.20151648 148.50 7.44353999e-02 3.27988242e-02 8.13412050e-02 0.41503855 0.18494817 148.75 5.17769349e-02 1.34569735e-02 5.34971132e-02 0.25427707 0.06968503 149.00 2.55416728e-02 -2.97043888e-02 3.91756016e-02 -0.86060470 0.03643273 149.25 -1.48525211e-02 -3.11546912e-02 3.45139416e-02 -2.01565904 0.03015867 149.50 -2.44251682e-02 -4.74782888e-02 5.33926656e-02 -2.04593637 0.09899578 149.75 1.20592019e-02 -1.00835335e-01 1.01553873e-01 -1.45176863 0.13490133 150.00 -2.21694539e-02 -1.35664851e-01 1.37464310e-01 -1.73277800 0.14736818 150.25 -6.81616519e-02 -1.32420324e-01 1.48933384e-01 -2.04616398 0.38594877 150.50 -1.10027698e-01 -1.29652122e-01 1.70046368e-01 -2.27449906 0.58304176 150.75 -1.49802446e-01 -1.09966345e-01 1.85831563e-01 -2.50836120 0.64973686 151.00 -1.54897159e-01 -1.04519256e-01 1.86861994e-01 -2.54800412 0.64777584 151.25 -1.35073353e-01 -1.01654094e-01 1.69051370e-01 -2.49643960 0.58615677 151.50 -1.48514674e-01 -1.04011284e-01 1.81314521e-01 -2.53063620 0.63251091 151.75 -1.38821697e-01 -1.18752011e-01 1.82684164e-01 -2.43395560 0.63239179 152.00 -1.38255313e-01 -1.38937329e-01 1.96005390e-01 -2.35373405 0.58242902 152.25 -1.50569578e-01 -2.44117669e-01 2.86818120e-01 -2.12347074 0.64277996 152.50 -1.41122021e-01 -2.90494684e-01 3.22959109e-01 -2.02301871 0.64777257 152.75 -1.97601549e-01 -2.57460814e-01 3.24549600e-01 -2.22540460 0.64850704 153.00 -2.46980266e-01 -2.81054525e-01 3.74153575e-01 -2.29175351 0.69005087 153.25 -3.24113253e-01 -2.26605155e-01 3.95473510e-01 -2.53143454 0.65161300 153.50 -3.02291055e-01 -1.20095409e-01 3.25273407e-01 -2.76342982 0.58072808 153.75 -2.00505056e-01 -4.07202561e-02 2.04598183e-01 -2.94122922 0.48893107 154.00 -1.37673717e-01 -5.66435501e-02 1.48870897e-01 -2.75126901 0.45812617 154.25 -4.86144293e-02 -1.16025239e-01 1.25798326e-01 -1.96757289 0.36178495 154.50 -2.75151278e-02 -1.72493518e-01 1.74674257e-01 -1.72897767 0.43046195 154.75 6.13845584e-02 -2.07526275e-01 2.16414461e-01 -1.28320478 0.47474970 155.00 9.39245831e-02 -2.67028662e-01 2.83065599e-01 -1.23257250 0.43666543 155.25 1.28023278e-01 -3.68573316e-01 3.90174639e-01 -1.23648586 0.56613373 155.50 1.46144055e-01 -4.12249107e-01 4.37387026e-01 -1.23011447 0.52743970 155.75 1.41357203e-01 -4.99588310e-01 5.19201636e-01 -1.29505662 0.57183028 156.00 2.02266553e-01 -6.17494748e-01 6.49778057e-01 -1.25425078 0.57642377 156.25 3.47683345e-01 -7.80858524e-01 8.54765315e-01 -1.15189301 0.64978084 156.50 2.75491889e-01 -8.59075582e-01 9.02167743e-01 -1.26047294 0.44162573 156.75 -8.99840882e-02 -9.54383195e-01 9.58615887e-01 -1.66480349 0.40952741 157.00 -1.05147967e-01 -9.62403043e-01 9.68130008e-01 -1.67962034 0.42729927 157.25 -2.94970117e-01 -1.27154686e+00 1.30531176e+00 -1.79874194 0.55157329 157.50 -5.18908054e-01 -1.58820809e+00 1.67082928e+00 -1.88658807 0.54879948 157.75 -5.28956395e-01 -2.00033232e+00 2.06908779e+00 -1.82931336 0.56604898 158.00 -1.29971170e+00 -2.69327874e+00 2.99048505e+00 -2.02040783 0.48109324 158.25 -2.34234877e+00 -2.92253798e+00 3.74537394e+00 -2.24643760 0.46575586 158.50 -4.21768405e+00 -8.79337335e-01 4.30837474e+00 -2.93604885 0.43062829 158.75 -4.85987772e+00 5.07642372e-01 4.88631888e+00 3.03751430 0.57951043 159.00 -3.09506713e+00 1.73995554e+00 3.55061767e+00 2.62945351 0.56614221 159.25 -2.18068172e+00 1.62391407e+00 2.71890965e+00 2.50150387 0.65022559 159.50 -1.38528018e+00 1.54987511e+00 2.07872894e+00 2.30017608 0.63860043 159.75 -9.34377505e-01 1.41531374e+00 1.69592874e+00 2.15430242 0.65915757 160.00 -9.59912569e-01 7.92766082e-01 1.24495390e+00 2.45127325 0.64958910 160.25 -1.14420421e+00 6.39665453e-01 1.31086810e+00 2.63182910 0.75538884 160.50 -1.41244422e+00 6.04655445e-01 1.53642666e+00 2.73710635 0.83244412 160.75 -1.59293468e+00 5.50713816e-01 1.68544552e+00 2.80873334 0.88020990 161.00 -1.69527136e+00 3.91122590e-01 1.73980513e+00 2.91484638 0.89906534 161.25 -1.77165994e+00 3.65902880e-01 1.80905054e+00 2.93792515 0.91124298 161.50 -1.90979390e+00 3.66340310e-01 1.94461254e+00 2.95207287 0.87233342 161.75 -2.05868458e+00 2.60412872e-01 2.07508965e+00 3.01576614 0.84771075 162.00 -2.37303738e+00 -6.07335393e-02 2.37381444e+00 -3.11600507 0.87759655 162.25 -2.59403718e+00 -1.05023941e-01 2.59616235e+00 -3.10112808 0.82910222 162.50 -3.40317614e+00 -7.72369315e-02 3.40405250e+00 -3.11890101 0.83135964 162.75 -3.92854996e+00 1.30868097e-01 3.93072910e+00 3.10829291 0.75680452 163.00 -4.83711314e+00 1.64358176e+00 5.10872044e+00 2.81404627 0.67216049 163.25 -4.29568995e+00 2.93799509e+00 5.20430277e+00 2.54172658 0.56845148 163.50 -1.38288454e+00 4.82141375e+00 5.01581500e+00 1.85011923 0.44853133 163.75 8.68281548e-01 4.38967029e+00 4.47471989e+00 1.37551600 0.38929798 164.00 1.59436865e+00 3.53577053e+00 3.87861890e+00 1.14717312 0.52708678 164.25 1.41650889e+00 2.01865371e+00 2.46606168e+00 0.95892383 0.42846904 164.50 1.90525303e+00 1.20242856e+00 2.25295885e+00 0.56298258 0.62839700 164.75 1.72421962e+00 7.62421523e-01 1.88526387e+00 0.41633477 0.62363294 165.00 1.42086784e+00 6.78793735e-01 1.57468294e+00 0.44567487 0.76793010 165.25 1.33745351e+00 5.51675737e-01 1.44676467e+00 0.39122035 0.77377593 165.50 1.21927383e+00 4.23166059e-01 1.29061931e+00 0.33405684 0.86924099 165.75 1.08514147e+00 3.86775331e-01 1.15201006e+00 0.34239024 0.82520601 166.00 9.49956852e-01 4.01928581e-01 1.03148660e+00 0.40026187 0.88983786 166.25 8.76951343e-01 3.22505200e-01 9.34373192e-01 0.35240578 0.85963657 166.50 7.60559747e-01 3.02237771e-01 8.18412365e-01 0.37825314 0.86974363 166.75 6.59840523e-01 3.70300919e-01 7.56645417e-01 0.51139955 0.81483114 167.00 6.04520588e-01 4.59425671e-01 7.59287224e-01 0.64985999 0.79272181 167.25 6.15254145e-01 5.38420714e-01 8.17578454e-01 0.71889751 0.72607830 167.50 6.38439812e-01 6.62152974e-01 9.19810826e-01 0.80362872 0.68746231 167.75 9.95913521e-01 6.59137731e-01 1.19428066e+00 0.58465524 0.57776930 168.00 1.46264078e+00 4.77037963e-01 1.53846783e+00 0.31527024 0.73625489 168.25 1.68542522e+00 -1.44398118e-02 1.68548707e+00 -0.00856725 0.81390416 168.50 1.76275159e+00 -1.73931551e-01 1.77131176e+00 -0.09835213 0.87300581 168.75 1.77578393e+00 -2.78283842e-01 1.79745667e+00 -0.15544616 0.84499327 169.00 1.96166675e+00 -3.88237438e-01 1.99971617e+00 -0.19538709 0.86801751 169.25 2.06917467e+00 -1.05674387e+00 2.32340084e+00 -0.47217720 0.69363703 169.50 1.49268276e+00 -2.01350408e+00 2.50645178e+00 -0.93286337 0.65954797 169.75 -3.88844486e-01 -2.88695251e+00 2.91302159e+00 -1.70468088 0.77957541 170.00 -1.21698464e+00 -2.70227722e+00 2.96367235e+00 -1.99394561 0.84376589 170.25 -1.50297497e+00 -1.27541617e+00 1.97119765e+00 -2.43791517 0.80818882 170.50 -1.48088597e+00 -7.14462882e-01 1.64422641e+00 -2.69207819 0.86599140 170.75 -1.13992177e+00 -3.06943161e-01 1.18052350e+00 -2.87856427 0.89777304 171.00 -1.04658263e+00 -1.70242451e-01 1.06033848e+00 -2.98033992 0.92025828 171.25 -7.87497964e-01 7.81420541e-02 7.91365417e-01 3.04268816 0.81332281 171.50 -6.97872141e-01 2.02668372e-01 7.26704888e-01 2.85895797 0.79571736 171.75 -4.52180526e-01 2.15915921e-01 5.01085734e-01 2.69610702 0.50408843 172.00 -3.19277676e-01 1.89217418e-01 3.71135373e-01 2.60660088 0.35776736 172.25 -2.54059215e-01 1.08780313e-01 2.76367946e-01 2.73704079 0.11364051 172.50 -7.31580872e-02 -1.78081268e-01 1.92522839e-01 -1.96058930 0.05421224 172.75 -1.83009246e-02 -2.46565216e-01 2.47243463e-01 -1.64488394 0.16028454 173.00 4.49472667e-02 -2.28860018e-01 2.33231997e-01 -1.37686823 0.14395473 173.25 -2.18379550e-01 -2.26779290e-01 3.14830866e-01 -2.33732764 0.19530552 173.50 -3.76408154e-01 -1.69144052e-01 4.12665493e-01 -2.71926824 0.24585366 173.75 -2.31024204e-01 1.46896651e-01 2.73771454e-01 2.57522938 0.10083909 174.00 -1.09539214e-01 3.48804844e-02 1.14958635e-01 2.83331525 0.01409445 174.25 2.17903621e-01 -5.28079683e-01 5.71270636e-01 -1.17944626 0.38732795 174.50 2.92297161e-01 -3.06462439e-01 4.23505439e-01 -0.80905146 0.43594532 174.75 4.27252203e-01 1.29377333e-02 4.27448044e-01 0.03027201 0.62457563 175.00 5.01647577e-01 9.32684297e-02 5.10244345e-01 0.18382524 0.66130229 175.25 5.28323211e-01 1.34593883e-01 5.45198064e-01 0.24945053 0.72162233 175.50 5.71017162e-01 1.96924953e-01 6.04019897e-01 0.33209466 0.71047161 175.75 6.49730078e-01 2.58685647e-01 6.99333567e-01 0.37890471 0.77234170 176.00 7.33430446e-01 3.13532301e-01 7.97635708e-01 0.40397564 0.79320947 176.25 8.97992542e-01 4.05120262e-01 9.85146199e-01 0.42380146 0.86467802 176.50 1.05801380e+00 3.53992379e-01 1.11566295e+00 0.32287394 0.87621970 176.75 1.20332611e+00 2.83214931e-01 1.23620566e+00 0.23115317 0.94230954 177.00 1.34708502e+00 2.22684904e-01 1.36536684e+00 0.16382714 0.94341019 177.25 1.47374859e+00 1.31371562e-01 1.47959230e+00 0.08890610 0.95388797 177.50 1.57556051e+00 -1.11343731e-02 1.57559986e+00 -0.00706681 0.94741362 177.75 1.71392661e+00 -6.38475119e-02 1.71511542e+00 -0.03723497 0.95420663 178.00 1.91669618e+00 -2.24352518e-01 1.92978193e+00 -0.11652146 0.92257270 178.25 2.11531033e+00 -3.84820869e-01 2.15002905e+00 -0.17995371 0.93370939 178.50 2.52307099e+00 -5.73253953e-01 2.58737460e+00 -0.22341205 0.87226259 178.75 3.17954695e+00 -8.95213503e-01 3.30316909e+00 -0.27444895 0.82172239 179.00 3.24860010e+00 -3.01686416e+00 4.43338155e+00 -0.74842878 0.74867058 179.25 2.23600398e+00 -4.98732027e+00 5.46562688e+00 -1.14932558 0.79892607 179.50 9.80124072e-02 -5.08330831e+00 5.08425313e+00 -1.55151749 0.85286089 179.75 -1.06588052e+00 -4.31760159e+00 4.44722215e+00 -1.81282568 0.87006209 180.00 -1.93216336e+00 -3.02892906e+00 3.59272410e+00 -2.13862055 0.84073266 180.25 -2.29952059e+00 -2.51638623e+00 3.40881132e+00 -2.31119378 0.88185099 180.50 -2.24337057e+00 -1.30037926e+00 2.59300940e+00 -2.61626762 0.78507869 180.75 -1.95537079e+00 -8.19740989e-01 2.12024768e+00 -2.74462334 0.81162040 181.00 -1.34682498e+00 -2.86858791e-01 1.37703503e+00 -2.93173952 0.69082565 181.25 -9.88802881e-01 -2.02551300e-01 1.00933551e+00 -2.93954284 0.67853986 181.50 -6.64798031e-01 -3.02162655e-01 7.30245638e-01 -2.71498794 0.66115888 181.75 -7.01822043e-01 -3.33157180e-01 7.76883445e-01 -2.69838650 0.70651313 182.00 -5.72769091e-01 -2.10489507e-01 6.10221488e-01 -2.78941830 0.57286454 182.25 -4.56500766e-01 -1.77187836e-01 4.89682018e-01 -2.77134894 0.48959844 182.50 -1.86297513e-01 -8.12375531e-03 1.86474552e-01 -3.09801391 0.12659323 182.75 -1.21316342e-02 -2.03391106e-02 2.36823979e-02 -2.10861492 0.00227211 183.00 1.01513075e-01 -1.65730067e-01 1.94348552e-01 -1.02122136 0.16576494 183.25 2.23453575e-01 -2.21816090e-01 3.14855329e-01 -0.78172067 0.30176991 183.50 4.18151524e-01 -4.94302932e-01 6.47445817e-01 -0.86866297 0.64897435 183.75 4.52029025e-01 -6.46628378e-01 7.88960392e-01 -0.96070464 0.71644428 184.00 4.00979659e-01 -7.27456311e-01 8.30648765e-01 -1.06702623 0.73940329 184.25 4.44599173e-01 -7.82893066e-01 9.00327706e-01 -1.05431986 0.71522234 184.50 5.79757120e-01 -1.02399151e+00 1.17672296e+00 -1.05562050 0.74852279 184.75 7.59309845e-01 -1.08081645e+00 1.32087684e+00 -0.95837200 0.70022772 185.00 1.15042014e+00 -1.74312120e+00 2.08852533e+00 -0.98743925 0.81746045 185.25 7.92937302e-01 -2.41345620e+00 2.54037801e+00 -1.25335833 0.63099114 185.50 -1.17465060e+00 -4.51152460e+00 4.66193717e+00 -1.82550780 0.79725244 185.75 -2.57147157e+00 -3.44636540e+00 4.29998843e+00 -2.21182255 0.73506755 186.00 -2.94669105e+00 -8.54094271e-01 3.06797412e+00 -2.85947489 0.76707565 186.25 -2.34043797e+00 -7.57755508e-02 2.34166433e+00 -3.10922731 0.79057486 186.50 -1.83373296e+00 1.39049348e-01 1.83899736e+00 3.06590892 0.84727436 186.75 -1.32272610e+00 4.33190358e-02 1.32343525e+00 3.10885454 0.78906252 187.00 -1.11848443e+00 8.77114453e-02 1.12191832e+00 3.06333291 0.88625396 187.25 -9.30931529e-01 6.91873057e-02 9.33499007e-01 3.06740853 0.85094097 187.50 -7.80027380e-01 8.28262197e-02 7.84412453e-01 3.03580531 0.90336888 187.75 -7.21205516e-01 4.86910967e-02 7.22847300e-01 3.07418147 0.86451840 188.00 -6.99929251e-01 1.49069441e-02 7.00087976e-01 3.12029809 0.89575888 188.25 -7.30578926e-01 2.69501997e-02 7.31075838e-01 3.10472055 0.91461491 188.50 -7.16526293e-01 1.88885913e-02 7.16775214e-01 3.11523742 0.93572266 188.75 -6.73114834e-01 3.95891469e-03 6.73126476e-01 3.13571124 0.86977575 189.00 -6.82780713e-01 -2.89718145e-02 6.83395104e-01 -3.09918600 0.85397892 189.25 -6.29893456e-01 -3.96287122e-02 6.31138813e-01 -3.07876211 0.77441386 189.50 -5.85775684e-01 -4.21680480e-02 5.87291492e-01 -3.06972993 0.76215648 189.75 -6.62583759e-01 -3.33135218e-02 6.63420702e-01 -3.09135675 0.76071321 190.00 -7.36533085e-01 -2.64217766e-02 7.37006849e-01 -3.10573486 0.84632801 190.25 -7.65593517e-01 -2.11260462e-02 7.65884941e-01 -3.11400532 0.83102043 190.50 -8.09898932e-01 -6.57942365e-02 8.12567019e-01 -3.06053307 0.87591456 190.75 -9.41055924e-01 -6.38928882e-02 9.43222431e-01 -3.07380180 0.89281468 191.00 -1.02032926e+00 -8.30746315e-02 1.02370562e+00 -3.06035242 0.91961869 191.25 -1.19640885e+00 -3.23957897e-02 1.19684737e+00 -3.11452174 0.89748242 191.50 -1.28416638e+00 1.06280113e-01 1.28855684e+00 3.05901889 0.89406562 191.75 -1.15329438e+00 4.03948364e-01 1.22199109e+00 2.80468972 0.86443928 192.00 -1.01766925e+00 4.79643547e-01 1.12503717e+00 2.70115462 0.85791477 192.25 -8.84401363e-01 4.42868388e-01 9.89089571e-01 2.67734124 0.83578880 192.50 -7.88984084e-01 4.06764049e-01 8.87667098e-01 2.66557926 0.80696158 192.75 -6.47339392e-01 2.63714251e-01 6.98994631e-01 2.75473895 0.63356513 193.00 -6.40802722e-01 1.66871418e-01 6.62173843e-01 2.88684062 0.59578240 193.25 -7.81374160e-01 1.06172980e-01 7.88554551e-01 3.00653995 0.75069382 193.50 -8.75632573e-01 9.92163214e-02 8.81235656e-01 3.02876570 0.78908467 193.75 -9.01849352e-01 1.81154441e-01 9.19863678e-01 2.94336074 0.82867018 194.00 -8.58920187e-01 3.01387319e-01 9.10262711e-01 2.80412434 0.80557886 194.25 -8.64841425e-01 3.30854689e-01 9.25967340e-01 2.77620961 0.85547839 194.50 -8.42132608e-01 3.36692684e-01 9.06945033e-01 2.76125044 0.85758286 194.75 -8.44986443e-01 3.74970602e-01 9.24448506e-01 2.72394059 0.81775469 195.00 -8.25048486e-01 3.77973438e-01 9.07506983e-01 2.71200446 0.77930594 195.25 -8.31782409e-01 4.36400373e-01 9.39312121e-01 2.65841466 0.85146908 195.50 -8.56021859e-01 4.96816611e-01 9.89747528e-01 2.61572575 0.87351519 195.75 -8.16968216e-01 5.73725676e-01 9.98297660e-01 2.52935023 0.89290742 196.00 -7.35401701e-01 6.45371353e-01 9.78427230e-01 2.42130518 0.83897917 196.25 -6.56024600e-01 7.80200191e-01 1.01935304e+00 2.26994925 0.85565370 196.50 -4.99452680e-01 7.74209218e-01 9.21332129e-01 2.14372860 0.82584657 196.75 -3.81187210e-01 6.93003034e-01 7.90921547e-01 2.07367891 0.83535858 197.00 -2.89056565e-01 5.04760328e-01 5.81667161e-01 2.09087103 0.70829460 197.25 -2.65423764e-01 3.40985654e-01 4.32112243e-01 2.23222804 0.75177849 197.50 -3.66959265e-01 2.87114333e-01 4.65933195e-01 2.47766680 0.72610703 197.75 -5.34007080e-01 3.42931881e-01 6.34638351e-01 2.57073019 0.79618759 198.00 -6.28578898e-01 5.20168105e-01 8.15896004e-01 2.45028889 0.81746017 198.25 -6.66857780e-01 6.92578480e-01 9.61438636e-01 2.33727663 0.91769283 198.50 -5.79055427e-01 8.01971256e-01 9.89172928e-01 2.19616168 0.87549536 198.75 -4.60238322e-01 9.70275025e-01 1.07389615e+00 2.01370440 0.87331640 199.00 -1.98176279e-01 1.04861758e+00 1.06717977e+00 1.75758148 0.80446981 199.25 9.20731999e-02 1.10155941e+00 1.10540066e+00 1.48740575 0.81164036 199.50 2.85426126e-01 9.05099500e-01 9.49038028e-01 1.26531411 0.73597151 199.75 3.57357761e-01 8.02215097e-01 8.78210471e-01 1.15172113 0.78418518 200.00 4.07267586e-01 7.54642036e-01 8.57526378e-01 1.07590842 0.73136624 200.25 5.69582606e-01 5.34778476e-01 7.81288912e-01 0.75389342 0.65974698 200.50 4.65898092e-01 2.34995315e-01 5.21808231e-01 0.46715511 0.45191149 200.75 3.57401592e-01 8.08910078e-02 3.66441337e-01 0.22258081 0.37358635 201.00 2.40399479e-01 -2.58691142e-02 2.41787346e-01 -0.10719637 0.13858372 201.25 2.02248401e-01 -5.72630283e-02 2.10198644e-01 -0.27591079 0.12912277 201.50 6.46361218e-03 -5.68048556e-03 8.60501008e-03 -0.72100114 0.00019972 201.75 -1.72289030e-04 4.49907053e-02 4.49910352e-02 1.57462574 0.00691244 202.00 -3.80083375e-02 2.88808246e-02 4.77361053e-02 2.49181414 0.00776031 202.25 -7.03279642e-02 5.64500670e-02 9.01811100e-02 2.46522647 0.02808008 202.50 -1.41154843e-03 1.30211267e-01 1.30218918e-01 1.58163635 0.05948416 202.75 -3.65723002e-02 1.18168842e-01 1.23698862e-01 1.87093838 0.06832782 203.00 1.87690614e-02 1.87295326e-01 1.88233411e-01 1.47091872 0.12156991 203.25 5.26868301e-02 2.20668580e-01 2.26871162e-01 1.33642414 0.13206581 203.50 9.19769957e-02 3.06688093e-01 3.20183314e-01 1.27942758 0.18673211 203.75 6.25019838e-02 3.31003640e-01 3.36852947e-01 1.38416804 0.15707638 204.00 -1.01091071e-01 5.18348396e-01 5.28114063e-01 1.76340401 0.28025347 204.25 -1.04582150e-04 6.21861866e-01 6.21861874e-01 1.57096450 0.31467846 204.50 3.24429856e-01 7.39170201e-01 8.07234363e-01 1.15720227 0.37270305 204.75 4.26039275e-01 7.04613999e-01 8.23401695e-01 1.02697052 0.33255342 205.00 5.02291774e-01 7.41311682e-01 8.95455212e-01 0.97528207 0.33497072 205.25 3.99458085e-01 5.46094457e-01 6.76598786e-01 0.93925267 0.18274833 205.50 2.86668068e-01 1.60279027e-01 3.28432561e-01 0.50981065 0.03117053 205.75 2.75330665e-01 1.29940700e-01 3.04452888e-01 0.44095209 0.02872539 206.00 2.20284674e-01 2.38702976e-01 3.24814483e-01 0.82550474 0.04633543 206.25 7.90567993e-02 6.40783510e-02 1.01764496e-01 0.68113216 0.00614623 206.50 -2.72528935e-02 -2.09554047e-02 3.43780335e-02 -2.48608977 0.00079005 206.75 -6.91907024e-02 -2.68946830e-02 7.42339361e-02 -2.77086222 0.00369053 207.00 -1.05752668e-01 -1.79957190e-01 2.08730010e-01 -2.10208886 0.03351241 207.25 -9.87237551e-02 -1.55618856e-01 1.84292181e-01 -2.13612277 0.02740264 207.50 -2.37559130e-01 -2.09051156e-01 3.16443875e-01 -2.41993989 0.06200875 207.75 -2.05394110e-01 -2.96051837e-01 3.60324063e-01 -2.17733391 0.09552381 208.00 -1.78449793e-01 -4.48853606e-01 4.83025764e-01 -1.94920432 0.23692835 208.25 -1.36309320e-01 -5.38357090e-01 5.55345466e-01 -1.81877977 0.21969227 208.50 -2.70385938e-01 -7.92171473e-01 8.37044920e-01 -1.89971981 0.31591581 208.75 -1.91348987e-01 -5.06275492e-01 5.41229441e-01 -1.93215453 0.12082272 209.00 -1.36402294e-01 -1.88214071e-01 2.32443805e-01 -2.19792024 0.01933914 209.25 -3.19547911e-01 -3.49374466e-01 4.73469518e-01 -2.31163504 0.09423549 209.50 -3.22754268e-01 -4.00252647e-01 5.14171663e-01 -2.24941321 0.10755617 209.75 -1.06791281e-01 -4.14436189e-02 1.14551085e-01 -2.77140371 0.00645257 210.00 -8.04282694e-02 2.37192829e-03 8.04632373e-02 3.11210997 0.00334393 210.25 -9.82469246e-02 -2.22334014e-01 2.43073800e-01 -1.98688459 0.03462279 210.50 -1.44145177e-01 -3.79730490e-01 4.06168780e-01 -1.93359257 0.10310060 210.75 1.05743696e-01 -4.32570449e-01 4.45307672e-01 -1.33104394 0.11062669 211.00 8.94535424e-02 -4.98372628e-01 5.06337054e-01 -1.39319618 0.11671148 211.25 -3.75351973e-03 -3.18823858e-01 3.18845952e-01 -1.58256880 0.07036690 211.50 -1.08670082e-01 -2.41015266e-01 2.64381439e-01 -1.99438568 0.05489850 211.75 -3.25895922e-02 -2.07272784e-01 2.09819180e-01 -1.72675001 0.02215040 212.00 -1.56734539e-01 -2.26658578e-01 2.75571818e-01 -2.17579518 0.03854167 212.25 -9.16853162e-02 -2.42654345e-01 2.59398011e-01 -1.93205741 0.03799353 212.50 -1.38312418e-01 -1.93256160e-01 2.37651569e-01 -2.19197820 0.03199146 212.75 -6.92179248e-02 -2.43766728e-01 2.53403509e-01 -1.84746547 0.04763769 213.00 -8.72964346e-02 -2.68320391e-01 2.82163959e-01 -1.88533935 0.05700780 213.25 -1.10072839e-01 6.20462638e-03 1.10247573e-01 3.08528387 0.00816430 213.50 -1.34645509e-01 -9.46457222e-02 1.64581973e-01 -2.52890616 0.02205679 213.75 -1.52138623e-01 4.72198547e-02 1.59298070e-01 2.84064592 0.01848181 214.00 -2.36164602e-01 4.09220279e-02 2.39683816e-01 2.97001872 0.05172202 214.25 -3.40052078e-01 4.61235586e-02 3.43165847e-01 3.00677863 0.10510039 214.50 -2.69811344e-01 9.48375940e-03 2.69977968e-01 3.10645752 0.07073318 214.75 -2.57902693e-01 2.83172622e-02 2.59452629e-01 3.03223248 0.06933217 215.00 -2.38494257e-01 -5.59754302e-03 2.38559936e-01 -3.11812661 0.05606691 215.25 -2.82235740e-01 -2.07317457e-01 3.50196432e-01 -2.50805034 0.10972311 215.50 -2.71605794e-01 -1.43864046e-01 3.07354146e-01 -2.65448425 0.08706508 215.75 -2.45414280e-01 -2.33540030e-02 2.46522977e-01 -3.04671681 0.04623969 216.00 -1.95476012e-01 -4.12983946e-02 1.99790962e-01 -2.93338354 0.02967173 216.25 -1.36141852e-01 -1.82880534e-01 2.27990994e-01 -2.21072343 0.03500082 216.50 -1.29738046e-01 -4.67248434e-02 1.37895510e-01 -2.79590643 0.01223862 216.75 -1.90984290e-01 1.39747186e-01 2.36652224e-01 2.50989321 0.04071121 217.00 -1.14350032e-01 8.99361121e-02 1.45480013e-01 2.47513881 0.01794066 217.25 -1.65689197e-01 -1.82716918e-02 1.66693625e-01 -3.03175954 0.02096618 217.50 -1.98040815e-01 7.41820531e-02 2.11478466e-01 2.78319059 0.03767625 217.75 -3.31712393e-01 2.25626024e-01 4.01173546e-01 2.54428903 0.16366027 218.00 -3.71342527e-01 2.58141598e-01 4.52252536e-01 2.53412399 0.18862989 218.25 -4.99033502e-01 2.85174877e-01 5.74768776e-01 2.62242709 0.38845006 218.50 -4.43230792e-01 1.60560881e-01 4.71416304e-01 2.79404560 0.32167447 218.75 -4.56057331e-01 1.31255196e-01 4.74569506e-01 2.86136192 0.42689028 219.00 -4.41924837e-01 1.74207223e-01 4.75021808e-01 2.76609537 0.38393687 219.25 -4.96085670e-01 1.54741800e-01 5.19659520e-01 2.83923120 0.46665491 219.50 -5.20218393e-01 2.03632245e-01 5.58653084e-01 2.76849070 0.60910875 219.75 -5.11392073e-01 2.27085570e-01 5.59544197e-01 2.72369462 0.72348850 220.00 -4.53263088e-01 1.51012608e-01 4.77757506e-01 2.81999120 0.63448373 220.25 -4.88682003e-01 1.43550940e-01 5.09329925e-01 2.85587849 0.74447457 220.50 -4.56321024e-01 1.72615281e-01 4.87877968e-01 2.77995299 0.67059555 220.75 -4.29694479e-01 1.98675878e-01 4.73401996e-01 2.70850334 0.70233106 221.00 -4.02573360e-01 1.63542176e-01 4.34524284e-01 2.75571692 0.65070880 221.25 -4.10693291e-01 1.57651996e-01 4.39912641e-01 2.77507009 0.63472982 221.50 -3.60479618e-01 1.55140706e-01 3.92446422e-01 2.73517982 0.48375054 221.75 -3.64353542e-01 1.38848727e-01 3.89913417e-01 2.77750015 0.54101949 222.00 -3.25728760e-01 1.15142504e-01 3.45480855e-01 2.80181033 0.47935931 222.25 -3.20298570e-01 1.00654949e-01 3.35741854e-01 2.83711108 0.52898571 222.50 -2.74453483e-01 5.54252628e-02 2.79994061e-01 2.94232496 0.43165577 222.75 -2.51751383e-01 6.00262684e-02 2.58808639e-01 2.90752824 0.44678681 223.00 -2.19981591e-01 -4.08317373e-03 2.20019482e-01 -3.12303335 0.35523265 223.25 -2.01852957e-01 -6.13799360e-02 2.10978939e-01 -2.84639474 0.41193403 223.50 -2.61627996e-01 -8.78770801e-02 2.75992009e-01 -2.81754681 0.55819165 223.75 -2.71716468e-01 -1.17330685e-01 2.95966770e-01 -2.73396557 0.62443159 224.00 -3.13243039e-01 -1.01226313e-01 3.29192904e-01 -2.82902965 0.64516106 224.25 -2.86041351e-01 -9.96935536e-02 3.02916588e-01 -2.80622938 0.49438785 224.50 -1.71892462e-01 -2.41520537e-01 2.96444242e-01 -2.18933787 0.39167748 224.75 -1.67515816e-01 -3.07741996e-01 3.50380771e-01 -2.06928251 0.39993620 225.00 -2.09543803e-01 -2.88360190e-01 3.56455053e-01 -2.19920079 0.44144154 225.25 -1.94939362e-01 -2.91084993e-01 3.50331026e-01 -2.16089538 0.35583404 225.50 -2.72436582e-01 -4.07804685e-01 4.90434861e-01 -2.15976053 0.54583448 225.75 -2.87255192e-01 -4.16287346e-01 5.05777322e-01 -2.17480685 0.43365563 226.00 -3.31864297e-01 -4.86218805e-01 5.88678722e-01 -2.16970853 0.32215428 226.25 -2.47741104e-01 -4.01088775e-01 4.71431713e-01 -2.12410834 0.18196204 226.50 -1.72959048e-01 -3.13056660e-01 3.57658084e-01 -2.07554526 0.05735826 226.75 4.70603875e-02 -4.88315042e-01 4.90577476e-01 -1.47472003 0.05447777 227.00 5.78463608e-01 -8.23627910e-01 1.00647061e+00 -0.95850424 0.17503003 227.25 6.11176703e-01 -1.47249330e+00 1.59429404e+00 -1.17737288 0.26659090 227.50 2.77392805e-01 -2.66292007e+00 2.67732890e+00 -1.46700202 0.45505875 227.75 -1.30980094e+00 -2.57774344e+00 2.89142521e+00 -2.04091818 0.43413496 228.00 -2.82445143e+00 -1.80919705e+00 3.35420927e+00 -2.57189071 0.60294664 228.25 -3.02797730e+00 -1.05781438e+00 3.20743165e+00 -2.80549981 0.52966171 228.50 -2.83652655e+00 2.95922932e-01 2.85192098e+00 3.03764288 0.50442281 228.75 -2.50703058e+00 6.51520393e-01 2.59030522e+00 2.88733951 0.52710832 229.00 -2.50790618e+00 1.27599339e+00 2.81385013e+00 2.67093913 0.55019017 229.25 -1.23392135e+00 1.29252764e+00 1.78694980e+00 2.33300155 0.31656842 229.50 -1.81961851e-01 1.15232100e+00 1.16659925e+00 1.72741211 0.21342557 229.75 -5.40080238e-01 6.72273937e-01 8.62345007e-01 2.24758473 0.18867985 230.00 -6.07874067e-01 5.36368050e-01 8.10679695e-01 2.41860537 0.23872030 230.25 -7.19098753e-01 5.16238825e-01 8.85214969e-01 2.51895600 0.18948345 230.50 -8.42248084e-01 9.81827663e-01 1.29358703e+00 2.27982261 0.26852224 230.75 -8.01391097e-01 8.65934920e-01 1.17986057e+00 2.31750283 0.30778381 231.00 -6.90798191e-01 9.62978526e-01 1.18512859e+00 2.19307573 0.32958439 231.25 -3.01852133e-01 9.62546566e-01 1.00876687e+00 1.87468068 0.23519779 231.50 -2.34259324e-01 1.01966918e+00 1.04623261e+00 1.79661825 0.32707930 231.75 -6.41035633e-02 1.12300539e+00 1.12483349e+00 1.62781660 0.32456821 232.00 1.48329426e-01 9.01129644e-01 9.13255853e-01 1.40765536 0.28848355 232.25 2.75958684e-03 6.65828932e-01 6.65834651e-01 1.56665176 0.17769917 232.50 1.82211470e-01 6.51218811e-01 6.76229961e-01 1.29797246 0.22660846 232.75 2.52231541e-01 4.68587278e-01 5.32160490e-01 1.07699507 0.19645325 233.00 1.74310139e-01 4.82005836e-01 5.12555998e-01 1.22379416 0.22849240 233.25 1.17291350e-01 5.41748340e-01 5.54300032e-01 1.35758189 0.21897680 233.50 1.70672930e-01 4.44553606e-01 4.76190253e-01 1.20422858 0.17470992 233.75 2.32118130e-01 3.90579343e-01 4.54346838e-01 1.03458455 0.15305935 234.00 2.92445722e-01 3.57237575e-01 4.61674328e-01 0.88479786 0.16211112 234.25 1.98381543e-01 3.86878890e-01 4.34776393e-01 1.09698160 0.15521475 234.50 3.74087414e-01 3.84080359e-01 5.36152138e-01 0.79857779 0.26624332 234.75 3.10269364e-01 1.93840217e-01 3.65843010e-01 0.55841820 0.17421801 235.00 2.90485070e-01 2.16829304e-01 3.62486583e-01 0.64121799 0.15955563 235.25 2.41469967e-01 1.56784387e-01 2.87904652e-01 0.57587696 0.09589011 235.50 2.69130835e-01 2.62250834e-02 2.70405550e-01 0.09713695 0.08461351 235.75 2.67497835e-01 -2.84698209e-02 2.69008592e-01 -0.10603095 0.10138085 236.00 2.11073647e-01 -5.05647395e-02 2.17045795e-01 -0.23512862 0.07809127 236.25 2.17049902e-02 2.34843972e-02 3.19784851e-02 0.82475449 0.00313695 236.50 -7.37254820e-02 1.24728582e-01 1.44888460e-01 2.10463660 0.05201149 236.75 -3.26290533e-02 3.98582596e-01 3.99915918e-01 1.65247691 0.29841997 237.00 8.70621660e-02 4.36946073e-01 4.45535287e-01 1.37412057 0.32368106 237.25 1.22804607e-01 5.12268161e-01 5.26782346e-01 1.33550931 0.36193339 237.50 1.47148156e-01 3.72283983e-01 4.00309810e-01 1.19438471 0.21911177 237.75 1.75932049e-01 3.66098249e-01 4.06177318e-01 1.12282159 0.35679050 238.00 1.06387844e-01 4.87189114e-01 4.98669837e-01 1.35580060 0.34203979 238.25 -2.94046269e-02 6.70092214e-01 6.70737063e-01 1.61464966 0.38709390 238.50 -1.98516272e-03 5.30956912e-01 5.30960623e-01 1.57453515 0.24327410 238.75 9.40502483e-02 4.24873601e-01 4.35158621e-01 1.35294867 0.22349641 239.00 -1.13277742e-01 2.11974755e-01 2.40343803e-01 2.06157798 0.07680261 239.25 -2.27354242e-01 1.01978831e-01 2.49177915e-01 2.71994855 0.10961853 239.50 -2.52698182e-01 -2.26583166e-01 3.39405807e-01 -2.41062852 0.17186605 239.75 -2.48680049e-01 -5.01178896e-01 5.59483738e-01 -2.03139144 0.36784684 240.00 -3.23626730e-01 -5.79441960e-01 6.63692131e-01 -2.08015306 0.29926556 240.25 -3.32097310e-01 -6.05214093e-01 6.90342467e-01 -2.07266166 0.31888062 240.50 -4.63986953e-01 -6.77679187e-01 8.21299564e-01 -2.17115978 0.38653825 240.75 -4.89569420e-01 -7.56990751e-01 9.01506081e-01 -2.14487008 0.40155242 241.00 -5.35617544e-01 -4.37155011e-01 6.91368684e-01 -2.45706939 0.27867207 241.25 -6.07369890e-01 -2.12921878e-01 6.43610060e-01 -2.80441568 0.27304757 241.50 -4.72308302e-01 -6.04355315e-02 4.76159202e-01 -3.01432643 0.16903485 241.75 -2.68740001e-01 -8.17563852e-02 2.80900862e-01 -2.84626778 0.08950389 242.00 9.49040907e-02 -1.05389273e-01 1.41822725e-01 -0.83769954 0.03107724 242.25 3.54711034e-01 -6.35527406e-02 3.60359360e-01 -0.17728659 0.15601107 242.50 5.34022111e-01 -2.28067776e-01 5.80684532e-01 -0.40362732 0.22848788 242.75 8.74234384e-01 -1.98318915e-01 8.96446401e-01 -0.22307334 0.40074491 243.00 1.52198792e+00 -6.13664484e-01 1.64104580e+00 -0.38326136 0.51336948 243.25 1.92152987e+00 -1.03070373e+00 2.18051077e+00 -0.49233985 0.61271993 243.50 2.52214966e+00 -2.05921970e+00 3.25601362e+00 -0.68469378 0.64517525 243.75 2.75944584e+00 -2.85162154e+00 3.96815912e+00 -0.80182417 0.65060460 244.00 1.91486167e+00 -5.16396389e+00 5.50756010e+00 -1.21570205 0.52632808 244.25 1.67278631e+00 -7.39221941e+00 7.57912408e+00 -1.34825426 0.65061677 244.50 -1.65829236e+00 -1.06400312e+01 1.07684817e+01 -1.72540657 0.70534739 244.75 -4.39862697e+00 -1.09930822e+01 1.18404297e+01 -1.95141202 0.78494050 245.00 -8.92139232e+00 -9.46090247e+00 1.30038424e+01 -2.32685347 0.76624274 245.25 -1.06029908e+01 -5.92788512e+00 1.21475609e+01 -2.63180748 0.73966728 245.50 -1.02650720e+01 -1.89177416e+00 1.04379362e+01 -2.95934521 0.82382205 245.75 -1.02961004e+01 -6.71434001e-01 1.03179701e+01 -3.07647240 0.82867128 246.00 -8.59376010e+00 6.71051344e-01 8.61992011e+00 3.06366490 0.75947567 246.25 -7.42267629e+00 1.80726485e+00 7.63952417e+00 2.90276088 0.70559534 246.50 -6.11150557e+00 3.87309921e+00 7.23542658e+00 2.57673381 0.73203052 246.75 -4.90109238e+00 3.60673180e+00 6.08516399e+00 2.50717441 0.69848595 247.00 -3.34563450e+00 4.14038187e+00 5.32315998e+00 2.25042641 0.66533732 247.25 -2.54788322e+00 3.53458119e+00 4.35717490e+00 2.19537530 0.62711709 247.50 -2.48170570e+00 3.40210735e+00 4.21108033e+00 2.20102258 0.66225154 247.75 -1.67950961e+00 3.17475543e+00 3.59163257e+00 2.05738963 0.60570568 248.00 -1.02887151e+00 3.06587089e+00 3.23390490e+00 1.89457530 0.63594475 248.25 -8.51406193e-01 2.65544154e+00 2.78859504e+00 1.88106791 0.56186439 248.50 -5.92435547e-01 2.22729561e+00 2.30473982e+00 1.83076569 0.39637348 248.75 2.74887245e-02 1.49758811e+00 1.49784037e+00 1.55244306 0.22162982 249.00 4.61914563e-01 1.80578750e+00 1.86392960e+00 1.32036939 0.32659342 249.25 5.43923262e-02 1.49161792e+00 1.49260931e+00 1.53434716 0.24181877 249.50 -2.40072392e-01 1.27638463e+00 1.29876575e+00 1.75671206 0.22779205 249.75 6.14349192e-02 1.14058181e+00 1.14223514e+00 1.51698553 0.08375302 250.00 2.04035127e-01 2.80870282e+00 2.81610402e+00 1.49827981 0.20023360 250.25 4.34095883e-02 1.58669978e+00 1.58729347e+00 1.54344474 0.16812509 250.50 -5.02635464e-02 8.55290131e-01 8.56765797e-01 1.62949664 0.11717208 250.75 -2.04225851e-01 6.22441007e-01 6.55088548e-01 1.88783380 0.05622946 251.00 -1.64195947e-01 8.69974995e-01 8.85334288e-01 1.75733842 0.09984353 251.25 -3.29741069e-01 1.09818024e+00 1.14661633e+00 1.86249286 0.20967787 251.50 -3.97990285e-01 1.18419830e+00 1.24928855e+00 1.89502057 0.28345117 251.75 -1.59953701e-01 1.06047919e+00 1.07247438e+00 1.72049941 0.23589667 252.00 -1.06063190e-01 1.30624563e+00 1.31054457e+00 1.65181556 0.25946915 252.25 3.33132108e-01 1.24796376e+00 1.29166193e+00 1.30993827 0.28113629 252.50 6.41146835e-01 5.95360979e-01 8.74942261e-01 0.74838671 0.21511174 252.75 6.05281449e-01 4.96804759e-01 7.83058491e-01 0.68728569 0.28937366 253.00 4.35021298e-01 3.73040365e-01 5.73064258e-01 0.70884484 0.21596224 253.25 1.12762422e-01 2.10444889e-01 2.38751786e-01 1.07889821 0.05463736 253.50 1.52953967e-01 2.46653719e-01 2.90229174e-01 1.01571667 0.08741594 253.75 6.34305687e-02 2.32053679e-01 2.40566720e-01 1.30396998 0.04339463 254.00 -1.18870242e-01 2.65697959e-01 2.91076519e-01 1.99147650 0.07464111 254.25 -2.47889684e-01 2.09651817e-01 3.24658559e-01 2.43957319 0.10464615 254.50 -3.54134317e-01 2.37632847e-01 4.26474483e-01 2.55057907 0.18166809 254.75 -5.70622475e-01 1.14006797e-01 5.81899956e-01 2.94439543 0.32491373 255.00 -5.37832021e-01 2.23369190e-02 5.38295663e-01 3.10008510 0.35135397 255.25 -5.60257689e-01 -1.70213065e-02 5.60516193e-01 -3.11122079 0.38055688 255.50 -6.79660156e-01 1.99281346e-02 6.79952247e-01 3.11228032 0.48516512 255.75 -6.02315619e-01 4.96700944e-02 6.04360177e-01 3.05931360 0.48195400 256.00 -6.00129879e-01 7.89424373e-02 6.05299744e-01 3.01080133 0.43824766 256.25 -8.55059258e-01 -6.95746041e-03 8.55087563e-01 -3.13345602 0.62943012 256.50 -9.19501812e-01 2.05587862e-02 9.19731617e-01 3.11923776 0.65161969 256.75 -9.88438562e-01 2.05516309e-01 1.00957800e+00 2.93659328 0.73336206 257.00 -9.90188740e-01 3.09142499e-01 1.03732484e+00 2.83897599 0.72549457 257.25 -9.68782755e-01 4.83645034e-01 1.08279848e+00 2.67856155 0.70363823 257.50 -9.89771474e-01 4.93666386e-01 1.10605338e+00 2.67893109 0.77085683 257.75 -1.00961261e+00 4.06818045e-01 1.08849371e+00 2.75855033 0.80982395 258.00 -1.06350266e+00 4.15063389e-01 1.14162845e+00 2.76949392 0.76258724 258.25 -1.03725952e+00 4.51300193e-01 1.13118486e+00 2.73120767 0.76441076 258.50 -1.07756861e+00 4.36007238e-01 1.16243556e+00 2.75710874 0.72913889 258.75 -1.07969790e+00 3.00213656e-01 1.12065864e+00 2.87038996 0.70681670 259.00 -1.02214907e+00 2.70009019e-01 1.05721029e+00 2.88333369 0.68120326 259.25 -1.15352351e+00 2.06884188e-01 1.17192899e+00 2.96412960 0.69016192 259.50 -1.34792702e+00 -8.44057164e-02 1.35056713e+00 -3.07905540 0.66478531 259.75 -1.63593139e+00 -3.94432696e-01 1.68280975e+00 -2.90500227 0.69158362 260.00 -1.82961014e+00 -3.48301697e-01 1.86246808e+00 -2.95347425 0.69364719 260.25 -2.20077729e+00 -3.30332912e-01 2.22543041e+00 -2.99260658 0.65938048 260.50 -2.90137207e+00 1.72256786e-02 2.90142321e+00 3.13565564 0.63566452 260.75 -3.63326898e+00 -5.52482397e-01 3.67503473e+00 -2.99068663 0.69200671 261.00 -4.12525598e+00 3.23688738e-01 4.13793564e+00 3.06328796 0.67245875 261.25 -5.14077867e+00 9.80424784e-01 5.23343464e+00 2.95314049 0.70474584 261.50 -4.39834238e+00 3.34714382e+00 5.52709575e+00 2.49108788 0.53770412 261.75 -3.05540785e+00 6.18072090e+00 6.89469564e+00 2.02990963 0.66101582 262.00 -7.82944622e-01 5.54067726e+00 5.59572218e+00 1.71117535 0.66950266 262.25 3.18594011e-01 5.31485188e+00 5.32439223e+00 1.51092387 0.77469851 262.50 4.76472721e-01 4.19326365e+00 4.22024719e+00 1.45765347 0.79439736 262.75 6.13613058e-01 4.04336794e+00 4.08966322e+00 1.42018760 0.86476625 263.00 8.41919411e-01 3.31828589e+00 3.42342658e+00 1.32231845 0.82011897 263.25 7.54964683e-01 2.92804560e+00 3.02380931e+00 1.31845339 0.83247458 263.50 3.55469430e-01 2.56631277e+00 2.59081450e+00 1.43315843 0.83404334 263.75 2.02543665e-01 2.58704132e+00 2.59495794e+00 1.49266408 0.88496984 264.00 5.10912114e-01 2.58257422e+00 2.63262622e+00 1.37548763 0.87007129 264.25 4.09777232e-01 2.53528183e+00 2.56818444e+00 1.41055230 0.89204663 264.50 3.24210052e-01 2.58574418e+00 2.60599024e+00 1.44606360 0.91202031 264.75 3.68441215e-01 2.55404883e+00 2.58048723e+00 1.42752699 0.91359032 265.00 5.31249138e-01 2.31429109e+00 2.37448287e+00 1.34515389 0.89047211 265.25 6.20454322e-01 2.15565854e+00 2.24317349e+00 1.29054553 0.86641512 265.50 6.53357957e-01 2.10170123e+00 2.20091451e+00 1.26939622 0.90637079 265.75 6.28696818e-01 2.13962159e+00 2.23007628e+00 1.28500457 0.90485215 266.00 4.63952280e-01 2.05598916e+00 2.10768668e+00 1.34885481 0.88202656 266.25 5.02896360e-01 2.05577117e+00 2.11638840e+00 1.33088132 0.85808805 266.50 4.60672049e-01 1.97582061e+00 2.02881390e+00 1.34173372 0.87422165 266.75 3.83378465e-01 1.99021730e+00 2.02680634e+00 1.38049584 0.84617764 267.00 4.54301996e-01 2.12939275e+00 2.17731573e+00 1.36059957 0.83496600 267.25 5.57801572e-01 2.06495954e+00 2.13897183e+00 1.30696601 0.83062157 267.50 5.29598687e-01 1.82283377e+00 1.89820909e+00 1.28804463 0.75262932 267.75 4.27434399e-01 1.67554965e+00 1.72920987e+00 1.32102251 0.72092444 268.00 2.71735331e-01 1.91525186e+00 1.93443268e+00 1.42985731 0.82745305 268.25 3.75040383e-01 1.88056679e+00 1.91759921e+00 1.37394944 0.81176897 268.50 5.67976448e-01 2.11993658e+00 2.19470462e+00 1.30902284 0.85096581 268.75 5.91181531e-01 2.18157466e+00 2.26025742e+00 1.30616344 0.84744596 269.00 8.61703040e-01 2.14347887e+00 2.31020211e+00 1.18855715 0.88618897 269.25 8.20035891e-01 2.06422886e+00 2.22114827e+00 1.19265411 0.86117046 269.50 6.81843150e-01 2.00268610e+00 2.11557597e+00 1.24264168 0.81278442 269.75 5.47651654e-01 1.82200689e+00 1.90253291e+00 1.27881112 0.72708724 270.00 4.38451046e-01 2.11162593e+00 2.15666488e+00 1.36606868 0.68257823 270.25 5.95961225e-01 2.84371716e+00 2.90549429e+00 1.36421485 0.55673479 270.50 4.61704729e-01 2.86294172e+00 2.89993217e+00 1.41090365 0.41903062 270.75 6.53182511e-01 2.98956804e+00 3.06009223e+00 1.35568939 0.56296640 271.00 8.03861647e-01 3.64691734e+00 3.73446109e+00 1.35384332 0.76888733 271.25 1.47591224e+00 4.57015489e+00 4.80256522e+00 1.25842352 0.81806287 271.50 2.24956889e+00 5.37420189e+00 5.82602833e+00 1.17437040 0.84013505 271.75 3.54513695e+00 5.35434512e+00 6.42160476e+00 0.98595868 0.77364993 272.00 4.98118537e+00 5.12400016e+00 7.14615878e+00 0.79953004 0.76738343 272.25 7.61382982e+00 3.02489444e+00 8.19270352e+00 0.37816753 0.72316363 272.50 9.60964377e+00 1.78588936e+00 9.77418305e+00 0.18374718 0.83825173 272.75 8.56265159e+00 -1.25108695e+00 8.65356694e+00 -0.14508316 0.82582643 273.00 8.21218971e+00 -3.34093746e+00 8.86577255e+00 -0.38637751 0.86351555 273.25 5.46256816e+00 -5.72978184e+00 7.91644180e+00 -0.80926830 0.76813342 273.50 3.61051242e+00 -6.21014024e+00 7.18342828e+00 -1.04417317 0.85009536 273.75 1.85625950e+00 -5.30666052e+00 5.62195208e+00 -1.23430143 0.80542240 274.00 7.46119408e-01 -4.78780896e+00 4.84559685e+00 -1.41620244 0.80055126 274.25 1.80955131e-01 -3.29151962e+00 3.29648997e+00 -1.51587545 0.68725784 274.50 6.96664329e-02 -2.87386667e+00 2.87471095e+00 -1.54655971 0.71637079 274.75 -2.73432217e-01 -2.57216588e+00 2.58665855e+00 -1.67670286 0.80103383 275.00 -4.91526406e-01 -2.22984546e+00 2.28337666e+00 -1.78775742 0.81480711 275.25 -3.65403351e-01 -1.86033202e+00 1.89587839e+00 -1.76474563 0.80177331 275.50 -3.39856798e-01 -1.66460857e+00 1.69894801e+00 -1.77219462 0.80967501 275.75 -5.21715574e-01 -1.46009230e+00 1.55050206e+00 -1.91397457 0.74576723 276.00 -5.24488287e-01 -1.31902128e+00 1.41947353e+00 -1.94926177 0.73974995 276.25 -2.17472146e-01 -1.16015712e+00 1.18036379e+00 -1.75609655 0.62202314 276.50 -2.73494455e-01 -1.06026791e+00 1.09497363e+00 -1.82324177 0.50752643 276.75 -4.00827067e-01 -1.24031368e+00 1.30347243e+00 -1.88336844 0.58137005 277.00 -4.19280489e-01 -1.23797532e+00 1.30704974e+00 -1.89735332 0.49231720 277.25 -6.92976343e-01 -1.35461236e+00 1.52157513e+00 -2.04365545 0.48462816 277.50 -8.73897086e-01 -1.29886950e+00 1.56548973e+00 -2.16304245 0.41596458 277.75 -1.22278689e+00 -1.01459336e+00 1.58890134e+00 -2.44897967 0.24334748 278.00 -1.11035454e+00 -6.21656846e-01 1.27253465e+00 -2.63120148 0.12313828 278.25 -1.14214047e+00 7.24629157e-01 1.35261682e+00 2.57622784 0.09355141 278.50 -1.44476280e-01 2.68103801e+00 2.68492798e+00 1.62463244 0.32826685 278.75 1.81846409e+00 3.64571828e+00 4.07407333e+00 1.10811361 0.56149351 279.00 2.35724894e+00 2.55354825e+00 3.47523110e+00 0.82534990 0.60730382 279.25 2.41129714e+00 1.13426063e+00 2.66475160e+00 0.43968386 0.63584205 279.50 2.04166842e+00 3.39372607e-01 2.06968203e+00 0.16471714 0.68492060 279.75 1.69504055e+00 5.11077335e-02 1.69581086e+00 0.03014220 0.77981713 280.00 1.37473203e+00 4.14903341e-02 1.37535799e+00 0.03017151 0.71531847 280.25 9.96944417e-01 2.06042509e-01 1.01801360e+00 0.20380457 0.68964981 280.50 8.96489653e-01 1.98062652e-01 9.18108116e-01 0.21743847 0.69635948 280.75 9.19842535e-01 2.27280189e-01 9.47505448e-01 0.24223418 0.80623620 281.00 9.42870182e-01 1.40630144e-01 9.53300067e-01 0.14805964 0.82009349 281.25 9.73772389e-01 8.05946579e-02 9.77101921e-01 0.08257719 0.87094500 281.50 8.50271331e-01 -7.83612638e-02 8.53874595e-01 -0.09190070 0.76929664 281.75 7.96571571e-01 -1.73670482e-01 8.15283818e-01 -0.21466326 0.80189528 282.00 7.29122741e-01 -2.58723317e-01 7.73665125e-01 -0.34098181 0.83092679 282.25 6.03339431e-01 -2.93014345e-01 6.70727870e-01 -0.45210527 0.81114357 282.50 4.82024689e-01 -2.41631135e-01 5.39197002e-01 -0.46467407 0.72874035 282.75 4.55671924e-01 -1.55793057e-01 4.81568664e-01 -0.32943833 0.74042063 283.00 3.94013162e-01 -8.45564478e-02 4.02984075e-01 -0.21139677 0.68149239 283.25 3.85040101e-01 -3.77034544e-02 3.86881674e-01 -0.09760967 0.72973045 283.50 3.99856575e-01 2.51453441e-02 4.00646439e-01 0.06280321 0.69091150 283.75 4.23038788e-01 2.53831296e-02 4.23799621e-01 0.05993005 0.78386679 284.00 4.62248854e-01 5.99391599e-02 4.66118768e-01 0.12894909 0.75535910 284.25 4.91122531e-01 6.60619078e-02 4.95545675e-01 0.13370950 0.81071504 284.50 4.99055824e-01 1.26315454e-02 4.99215657e-01 0.02530548 0.79853606 284.75 4.99789124e-01 -3.70517375e-02 5.01160652e-01 -0.07399937 0.82219006 285.00 4.52962629e-01 -3.57356146e-02 4.54370089e-01 -0.07873000 0.74689221 285.25 4.23166469e-01 -4.25857408e-02 4.25303898e-01 -0.10029822 0.74165035 285.50 3.95000879e-01 -6.76073412e-02 4.00744865e-01 -0.16951488 0.79213319 285.75 3.72783664e-01 -7.56040593e-02 3.80373019e-01 -0.20009551 0.80342787 286.00 3.53264407e-01 -8.01576759e-02 3.62244384e-01 -0.22312749 0.83157896 286.25 3.54576546e-01 -8.40650223e-02 3.64405619e-01 -0.23278757 0.85833593 286.50 3.50855251e-01 -9.87755262e-02 3.64494186e-01 -0.27442492 0.84056937 286.75 3.17233658e-01 -9.07440513e-02 3.29957083e-01 -0.27860815 0.84694957 287.00 2.88369852e-01 -9.48113592e-02 3.03556198e-01 -0.31765047 0.82904599 287.25 2.67041570e-01 -6.92223426e-02 2.75867600e-01 -0.25363670 0.81581790 287.50 2.70470249e-01 -5.21845160e-02 2.75458489e-01 -0.19059792 0.86965743 287.75 2.58962783e-01 -4.98403280e-02 2.63715341e-01 -0.19013647 0.83412781 288.00 2.36015925e-01 -1.03115171e-02 2.36241072e-01 -0.04366215 0.70566747 288.25 2.33017709e-01 -1.64772494e-02 2.33599555e-01 -0.07059493 0.72360033 288.50 2.50019335e-01 -2.26347960e-02 2.51041833e-01 -0.09028606 0.87064328 288.75 2.36354882e-01 -1.29477654e-02 2.36709262e-01 -0.05472634 0.82583183 289.00 2.32925095e-01 -1.44903433e-02 2.33375384e-01 -0.06213025 0.77786538 289.25 2.31820578e-01 -3.22250355e-03 2.31842975e-01 -0.01389996 0.75976275 289.50 2.12736429e-01 -1.11328423e-02 2.13027530e-01 -0.05228393 0.78116236 289.75 1.98003678e-01 3.28266483e-04 1.98003951e-01 0.00165788 0.73010355 290.00 1.88004308e-01 4.84750241e-02 1.94153156e-01 0.25234373 0.80143291 290.25 1.87383380e-01 4.56392575e-02 1.92861279e-01 0.23890918 0.73483178 290.50 1.81239193e-01 4.88998484e-02 1.87720111e-01 0.26353320 0.70646179 290.75 1.70493963e-01 8.23379448e-02 1.89334964e-01 0.44990475 0.63959552 291.00 1.69438115e-01 9.85717076e-02 1.96024632e-01 0.52689707 0.80388755 291.25 1.78414939e-01 8.94143652e-02 1.99566579e-01 0.46457488 0.74899506 291.50 1.56536199e-01 8.37345315e-02 1.77524797e-01 0.49119274 0.69497033 291.75 1.48276202e-01 1.20292330e-01 1.90934745e-01 0.68157642 0.60693172 292.00 1.57414540e-01 1.31103588e-01 2.04859679e-01 0.69445629 0.71833090 292.25 1.71593680e-01 1.25275912e-01 2.12458102e-01 0.63062537 0.69955194 292.50 1.79928560e-01 1.28810914e-01 2.21283841e-01 0.62131780 0.74046550 292.75 1.84240345e-01 1.11627203e-01 2.15418516e-01 0.54473048 0.63045380 293.00 1.72242569e-01 8.68993952e-02 1.92922284e-01 0.46725510 0.59928418 293.25 1.47320554e-01 1.37534473e-01 2.01541749e-01 0.75105707 0.62312178 293.50 1.47569174e-01 1.49627522e-01 2.10154839e-01 0.79232393 0.75550951 293.75 1.49436523e-01 1.41378046e-01 2.05715888e-01 0.75769524 0.63039402 294.00 1.61292622e-01 1.40782220e-01 2.14090970e-01 0.71760381 0.57870259 294.25 1.79767724e-01 1.63221088e-01 2.42811775e-01 0.73719304 0.65651300 294.50 1.93847378e-01 1.81615428e-01 2.65633149e-01 0.75283136 0.72976811 294.75 2.02566971e-01 1.70328677e-01 2.64660605e-01 0.69915867 0.57490998 295.00 1.89374774e-01 1.75012673e-01 2.57860894e-01 0.74600419 0.54426354 295.25 1.76270851e-01 2.14532709e-01 2.77661117e-01 0.88299273 0.48389688 295.50 1.67441215e-01 2.21354900e-01 2.77550990e-01 0.92318774 0.51273595 295.75 2.19652637e-01 1.87796356e-01 2.88989191e-01 0.70737218 0.39011822 296.00 2.31503717e-01 2.04106951e-01 3.08631850e-01 0.72258811 0.44551494 296.25 2.71707017e-01 1.59358574e-01 3.14991838e-01 0.53044048 0.44191649 296.50 2.57304534e-01 1.38447104e-01 2.92186967e-01 0.49363554 0.43912515 296.75 1.90462299e-01 1.07264089e-01 2.18589735e-01 0.51290400 0.39684107 297.00 1.69918583e-01 1.23885336e-01 2.10285286e-01 0.62998154 0.38257461 297.25 2.16922887e-01 1.92583271e-01 2.90075603e-01 0.72603150 0.49595647 297.50 2.24895887e-01 2.06632464e-01 3.05409783e-01 0.74310076 0.46635356 297.75 1.94242718e-01 1.65941815e-01 2.55473912e-01 0.70698592 0.45230306 298.00 1.75584667e-01 1.44489474e-01 2.27392136e-01 0.68855211 0.40214983 298.25 1.86120567e-01 1.47675759e-01 2.37589973e-01 0.67072897 0.36826784 298.50 1.98193155e-01 1.57953935e-01 2.53436328e-01 0.67289045 0.30965747 298.75 1.94793198e-01 1.62426977e-01 2.53627508e-01 0.69503909 0.21479079 299.00 1.70485888e-01 2.06743447e-01 2.67970690e-01 0.88121925 0.18416281 299.25 1.08854986e-01 2.58880151e-01 2.80835077e-01 1.17275690 0.18199056 299.50 1.73417400e-01 2.48368092e-01 3.02919633e-01 0.96126104 0.19473619 299.75 2.21552882e-01 2.63314918e-01 3.44122690e-01 0.87131689 0.25542719 300.00 2.36138128e-01 2.17307567e-01 3.20910882e-01 0.74389430 0.19490342 300.25 3.37650267e-01 2.92762285e-01 4.46897593e-01 0.71431400 0.37185005 300.50 3.59769935e-01 2.27391712e-01 4.25607092e-01 0.56365118 0.44914858 300.75 3.40543629e-01 2.04375133e-01 3.97163893e-01 0.54052520 0.58266385 301.00 2.67461912e-01 1.99053620e-01 3.33403987e-01 0.63979913 0.43599376 301.25 2.15036472e-01 1.77422176e-01 2.78781837e-01 0.68984732 0.43166383 301.50 2.13886664e-01 1.98975151e-01 2.92127739e-01 0.74929641 0.31931019 301.75 2.71605830e-01 2.72476154e-01 3.84724553e-01 0.78699778 0.39579546 302.00 3.01091911e-01 3.03870657e-01 4.27777646e-01 0.78999138 0.38964836 302.25 4.13229415e-01 2.79420390e-01 4.98832942e-01 0.59456473 0.54411323 302.50 3.83313015e-01 2.78919977e-01 4.74051919e-01 0.62904686 0.40317422 302.75 2.70854962e-01 3.38935976e-01 4.33866346e-01 0.89658420 0.46430539 303.00 3.55565024e-01 3.10068945e-01 4.71772442e-01 0.71715431 0.48572762 303.25 3.70255751e-01 3.34705202e-01 4.99116112e-01 0.73501174 0.51092906 303.50 3.12548808e-01 3.24671812e-01 4.50664557e-01 0.80442068 0.37229613 303.75 2.86503952e-01 3.11690889e-01 4.23362403e-01 0.82747821 0.35998021 304.00 2.78527306e-01 2.04316965e-01 3.45431444e-01 0.63289733 0.23349526 304.25 2.73186102e-01 2.02679639e-01 3.40161259e-01 0.63830370 0.28356141 304.50 3.76254719e-01 2.37999387e-01 4.45209301e-01 0.56400910 0.35909935 304.75 3.70964795e-01 2.81391265e-01 4.65613491e-01 0.64894371 0.36668096 305.00 3.70408029e-01 2.95519342e-01 4.73849965e-01 0.67341093 0.31203093 305.25 3.30810102e-01 2.52460321e-01 4.16138844e-01 0.65186908 0.24242396 305.50 2.74808178e-01 2.12879392e-01 3.47616412e-01 0.65908963 0.14247409 305.75 3.67809397e-01 2.24764810e-01 4.31048689e-01 0.54853436 0.19741022 306.00 5.93555310e-01 2.92185184e-01 6.61573948e-01 0.45743869 0.32783893 306.25 6.27093382e-01 2.56077530e-01 6.77363869e-01 0.38768926 0.37313447 306.50 7.14149393e-01 2.60920912e-01 7.60321694e-01 0.35029162 0.43701629 306.75 7.32666712e-01 2.88510770e-01 7.87425536e-01 0.37513434 0.51272860 307.00 6.76159929e-01 2.99683023e-01 7.39595946e-01 0.41719573 0.50146419 307.25 7.53948231e-01 2.93051284e-01 8.08898627e-01 0.37071753 0.61648471 307.50 7.38872572e-01 2.95814658e-01 7.95888805e-01 0.38081626 0.65704630 307.75 7.63425441e-01 2.66407721e-01 8.08573731e-01 0.33575126 0.66789888 308.00 7.66545377e-01 3.24900146e-01 8.32557457e-01 0.40089606 0.70568020 308.25 7.93540012e-01 3.75950195e-01 8.78091282e-01 0.44243888 0.71238190 308.50 8.25675260e-01 2.71816612e-01 8.69266303e-01 0.31803067 0.77260302 308.75 8.09669806e-01 2.26995164e-01 8.40887626e-01 0.27333808 0.71771328 309.00 9.17989788e-01 2.11159908e-01 9.41962716e-01 0.22609142 0.82774774 309.25 9.01403987e-01 1.99090280e-01 9.23128424e-01 0.21737701 0.81721835 309.50 8.94022433e-01 1.62318183e-01 9.08638158e-01 0.17960299 0.79415040 309.75 8.88804979e-01 1.63774183e-01 9.03767821e-01 0.18221940 0.73371935 310.00 8.24001073e-01 2.37002205e-01 8.57407613e-01 0.28006404 0.73900471 310.25 8.31699117e-01 2.78391042e-01 8.77054727e-01 0.32300313 0.71072644 310.50 8.68275576e-01 4.65867831e-01 9.85360499e-01 0.49245345 0.75675162 310.75 9.36945244e-01 5.49597228e-01 1.08624284e+00 0.53049650 0.76493006 311.00 1.12989903e+00 7.12531740e-01 1.33580436e+00 0.56262718 0.84083458 311.25 1.34017875e+00 7.75884994e-01 1.54857244e+00 0.52479132 0.78724797 311.50 1.71515573e+00 9.44304690e-01 1.95792505e+00 0.50327688 0.81523595 311.75 1.93856593e+00 8.05625923e-01 2.09930250e+00 0.39386339 0.74944118 312.00 2.20591075e+00 8.50645500e-01 2.36424195e+00 0.36804956 0.81079398 312.25 2.50519913e+00 6.62685283e-01 2.59136537e+00 0.25860091 0.78950871 312.50 2.82959214e+00 5.39552733e-02 2.83010651e+00 0.01906591 0.74627220 312.75 2.97767870e+00 -2.98708809e-01 2.99262383e+00 -0.09998151 0.60519432 313.00 2.94113617e+00 -2.40066402e-01 2.95091746e+00 -0.08144315 0.45126469 313.25 2.41379935e+00 -1.16565962e+00 2.68052041e+00 -0.44988633 0.28610180 313.50 2.87960047e+00 -1.93942819e+00 3.47181229e+00 -0.59272259 0.33392083 313.75 7.70048361e-01 -1.00122617e+00 1.26310266e+00 -0.91517953 0.04635353 314.00 -2.10812720e+00 -4.77208015e-01 2.16146426e+00 -2.91897855 0.13322216 314.25 -2.46682985e+00 -3.76014149e-01 2.49532286e+00 -2.99032890 0.49967038 314.50 -2.27837308e+00 -4.07298802e-01 2.31449265e+00 -2.96469390 0.65911972 314.75 -1.83314638e+00 -5.98545246e-01 1.92838846e+00 -2.82599334 0.69282898 315.00 -1.67644021e+00 -5.43848205e-01 1.76244791e+00 -2.82789759 0.71957291 315.25 -1.65039618e+00 -3.24634013e-01 1.68202105e+00 -2.94737154 0.73748860 315.50 -1.68833880e+00 -2.10236002e-01 1.70137800e+00 -3.01770794 0.74508802 315.75 -1.30366142e+00 4.20155148e-02 1.30433830e+00 3.10937495 0.70439312 316.00 -1.08817808e+00 -2.32439870e-02 1.08842630e+00 -3.12023544 0.70713147 316.25 -1.01619532e+00 -1.79648045e-01 1.03195268e+00 -2.96661560 0.76166345 316.50 -9.76510837e-01 -1.63424068e-01 9.90091330e-01 -2.97577422 0.76819193 316.75 -9.38080769e-01 -2.11526193e-03 9.38083154e-01 -3.13933777 0.75634961 317.00 -9.21805452e-01 3.67925031e-02 9.22539419e-01 3.10170031 0.79569161 317.25 -8.89208143e-01 1.22034160e-01 8.97543011e-01 3.00520552 0.75212756 317.50 -8.26475463e-01 1.66458352e-01 8.43071808e-01 2.94284410 0.74660749 317.75 -7.87102440e-01 2.73239664e-01 8.33180751e-01 2.80746240 0.82625488 318.00 -7.67027558e-01 2.89426344e-01 8.19816372e-01 2.78077643 0.81112145 318.25 -7.08398653e-01 3.15847966e-01 7.75621422e-01 2.72218530 0.67749222 318.50 -6.84344044e-01 3.37043871e-01 7.62840312e-01 2.68395782 0.64291368 318.75 -3.71269896e-01 3.82878118e-01 5.33326344e-01 2.34080321 0.50629304 319.00 -3.81341700e-01 4.03875316e-01 5.55460856e-01 2.32750505 0.50717814 319.25 -2.36758813e-01 4.10246427e-01 4.73663242e-01 2.09421762 0.53088701 319.50 -1.78741833e-01 3.47837778e-01 3.91075137e-01 2.04547471 0.40686928 319.75 -4.59935478e-02 3.20375062e-01 3.23659677e-01 1.71338365 0.29393941 320.00 -6.59961858e-02 2.31494631e-01 2.40718219e-01 1.84851625 0.22290500 320.25 -6.89363799e-02 1.87700004e-01 1.99958786e-01 1.92277191 0.26357088 320.50 -1.22339548e-01 1.62354957e-01 2.03288212e-01 2.21655366 0.22580821 320.75 -1.20578485e-01 1.91188926e-01 2.26036229e-01 2.13346767 0.32492442 321.00 -1.44833608e-01 1.90808390e-01 2.39550862e-01 2.22006598 0.32129003 321.25 -1.64613399e-01 2.14491008e-01 2.70377447e-01 2.22537889 0.43137894 321.50 -1.30460630e-01 2.33119116e-01 2.67141345e-01 2.08100352 0.34319834 321.75 -1.66239712e-01 3.04667731e-01 3.47070696e-01 2.07028802 0.47490102 322.00 -1.14628003e-01 3.00118109e-01 3.21263846e-01 1.93564005 0.39184715 322.25 -1.58074715e-02 2.57495947e-01 2.57980694e-01 1.63210859 0.38026723 322.50 4.11357083e-02 2.69655600e-01 2.72775162e-01 1.41941435 0.38030718 322.75 6.57860098e-02 2.79426449e-01 2.87066089e-01 1.33957474 0.44440390 323.00 6.01324738e-02 1.81026521e-01 1.90752498e-01 1.25008869 0.21088295 323.25 7.53790946e-02 1.59741241e-01 1.76633156e-01 1.12989467 0.28210812 323.50 5.69138494e-02 1.40555808e-01 1.51641424e-01 1.18605583 0.18318854 323.75 9.07498488e-02 1.38732898e-01 1.65778021e-01 0.99152073 0.28521567 324.00 2.35035447e-02 1.12176531e-01 1.14612350e-01 1.36426119 0.12449458 324.25 2.03985373e-02 1.01583982e-01 1.03611803e-01 1.37262717 0.13617885 324.50 4.44886221e-02 7.64850034e-02 8.84827285e-02 1.04396782 0.06114971 324.75 5.47994777e-03 7.59947493e-02 7.61920714e-02 1.49881137 0.05676976 325.00 3.28750922e-02 9.64080409e-02 1.01859128e-01 1.24216218 0.09626457 325.25 3.44480271e-02 9.76430197e-02 1.03541421e-01 1.23163318 0.13739289 325.50 5.87416951e-02 7.18921552e-02 9.28389397e-02 0.88572673 0.07875344 325.75 7.30570147e-02 1.05711242e-01 1.28499782e-01 0.96606868 0.13152196 326.00 2.76928870e-02 7.62416637e-02 8.11152715e-02 1.22238859 0.05080160 326.25 4.78866447e-02 8.33952943e-02 9.61660327e-02 1.04955386 0.08532105 326.50 2.74515169e-02 1.02204448e-01 1.05826910e-01 1.30839528 0.08193364 326.75 -3.27946434e-02 5.13055028e-02 6.08912412e-02 2.13954407 0.02928292 327.00 -9.56781742e-02 6.03326075e-02 1.13112053e-01 2.57899183 0.11960290 327.25 -9.03750009e-02 6.21745226e-02 1.09696454e-01 2.53899199 0.12932287 327.50 -1.16531157e-01 1.13753534e-01 1.62847711e-01 2.36825560 0.18688596 327.75 -7.97774553e-02 1.34488622e-01 1.56370176e-01 2.10619425 0.15948096 328.00 -1.19852155e-02 1.22519714e-01 1.23104532e-01 1.66830883 0.08669540 328.25 -5.87832730e-04 1.04129093e-01 1.04130752e-01 1.57644150 0.06964244 328.50 -6.10358132e-02 1.48856228e-01 1.60883645e-01 1.95992093 0.13310753 328.75 -9.31989979e-02 1.40747473e-01 1.68807299e-01 2.15568059 0.14458119 329.00 -1.29506355e-01 1.78657455e-01 2.20658973e-01 2.19803004 0.29165250 329.25 -1.28388702e-01 1.70671361e-01 2.13570532e-01 2.21574026 0.26343613 329.50 -1.39034386e-01 1.58857753e-01 2.11107428e-01 2.28974701 0.21566594 329.75 -1.13051163e-01 1.70707249e-01 2.04747480e-01 2.15573617 0.16100871 330.00 2.06260850e-03 2.29040690e-01 2.29049977e-01 1.56179115 0.22632549 330.25 -3.00710911e-03 1.85591938e-01 1.85616299e-01 1.58699771 0.14546430 330.50 -2.81026194e-02 9.21540778e-02 9.63438181e-02 1.86679051 0.05797147 330.75 -9.33334642e-02 4.17496613e-02 1.02245634e-01 2.72097201 0.06085339 331.00 -1.79503651e-01 8.46853648e-02 1.98477132e-01 2.70077878 0.23087189 331.25 -2.60567647e-01 1.33880869e-01 2.92949801e-01 2.66696241 0.31819376 331.50 -3.42391120e-01 1.84297072e-01 3.88840699e-01 2.64780385 0.51288477 331.75 -3.19283333e-01 2.58594546e-01 4.10868575e-01 2.46083102 0.59420023 332.00 -2.63338163e-01 2.43474010e-01 3.58645482e-01 2.39536875 0.65086470 332.25 -2.91182470e-01 2.71635550e-01 3.98212384e-01 2.39091098 0.56588155 332.50 -3.89273752e-01 2.21477867e-01 4.47868843e-01 2.62431590 0.62489908 332.75 -3.56969368e-01 3.21593172e-01 4.80467791e-01 2.40828136 0.58875072 333.00 -3.52417150e-01 4.70180145e-01 5.87594432e-01 2.21400069 0.70679416 333.25 -4.11177886e-01 4.81836403e-01 6.33430006e-01 2.27723538 0.66401203 333.50 -4.60012297e-01 5.36301285e-01 7.06562370e-01 2.27977235 0.70668161 333.75 -3.11311845e-01 6.54337290e-01 7.24618764e-01 2.01486998 0.52401994 334.00 -1.44144711e-01 6.95644140e-01 7.10421330e-01 1.77511527 0.51405207 334.25 -1.95770313e-01 4.45830014e-01 4.86919313e-01 1.98456088 0.28121000 334.50 -4.16417231e-01 3.59722968e-01 5.50276225e-01 2.42911141 0.44247966 334.75 -4.06618915e-01 4.14629920e-01 5.80738248e-01 2.34644014 0.36795374 335.00 -4.38299960e-01 5.14819289e-01 6.76125547e-01 2.27608325 0.48569888 335.25 -5.81010357e-01 5.55798992e-01 8.04043254e-01 2.37836816 0.40137853 335.50 -7.80190891e-01 6.65342934e-01 1.02536776e+00 2.43547815 0.39273293 335.75 -6.06783794e-01 1.05288743e+00 1.21521953e+00 2.09361044 0.29524104 336.00 -3.53638737e-01 1.27352428e+00 1.32171270e+00 1.84165715 0.27037815 336.25 -1.23274109e-01 1.15472614e+00 1.16128763e+00 1.67714966 0.20212988 336.50 -6.52332782e-02 1.12289051e+00 1.12478374e+00 1.62882517 0.18703974 336.75 7.23791128e-01 6.81258583e-01 9.93975279e-01 0.75513620 0.10266578 337.00 1.01143339e+00 3.13051865e-01 1.05877239e+00 0.30016138 0.12285985 337.25 7.42896292e-01 -7.48271752e-02 7.46655213e-01 -0.10038502 0.12359765 337.50 5.92236173e-01 -1.50507058e-01 6.11061420e-01 -0.24886523 0.09767702 337.75 1.11055967e-01 -3.50584744e-02 1.16458252e-01 -0.30578200 0.00380393 338.00 5.85383736e-02 -1.03250088e-01 1.18690024e-01 -1.05502748 0.00496439 338.25 3.05271099e-01 6.30794516e-02 3.11720165e-01 0.20376639 0.05610193 338.50 3.63851986e-01 -1.03664205e-02 3.63999630e-01 -0.02848306 0.10707768 338.75 2.67783100e-01 2.08276602e-01 3.39244648e-01 0.66104517 0.16060803 339.00 1.75574525e-01 2.39498391e-01 2.96961097e-01 0.93820398 0.15921953 339.25 9.46225175e-02 3.07776636e-01 3.21993600e-01 1.27252888 0.24645278 339.50 6.89464454e-02 3.41596699e-01 3.48485175e-01 1.37163619 0.26940540 339.75 2.26683636e-02 4.01492824e-01 4.02132245e-01 1.51439601 0.38301681 340.00 4.86596850e-03 4.42251962e-01 4.42278731e-01 1.55979406 0.39854317 340.25 5.39748525e-02 4.91525921e-01 4.94480551e-01 1.46142375 0.54992794 340.50 -1.21516376e-02 5.14294440e-01 5.14437978e-01 1.59441971 0.52399133 340.75 -5.01262323e-02 6.05628326e-01 6.07699192e-01 1.65337542 0.57788916 341.00 -1.05196444e-01 6.16472332e-01 6.25383425e-01 1.73981097 0.57158389 341.25 -1.60214880e-01 6.69326385e-01 6.88234420e-01 1.80574302 0.73464390 341.50 -1.71458331e-01 7.06888967e-01 7.27385710e-01 1.80875425 0.66215236 341.75 -2.50272231e-01 8.30417345e-01 8.67311453e-01 1.86351986 0.77093027 342.00 -2.72392253e-01 9.15220496e-01 9.54895856e-01 1.86007255 0.76285733 342.25 -3.67375813e-01 9.41209129e-01 1.01036608e+00 1.94293295 0.83240392 342.50 -4.70009064e-01 9.98396119e-01 1.10349596e+00 2.01078289 0.79926810 342.75 -5.47840235e-01 1.10540324e+00 1.23371197e+00 2.03091948 0.84349534 343.00 -6.30608060e-01 1.38617660e+00 1.52287625e+00 1.99773933 0.80397712 343.25 -7.66778802e-01 1.74882184e+00 1.90953595e+00 1.98400764 0.89983560 343.50 -7.00616706e-01 1.87993810e+00 2.00624800e+00 1.92753212 0.89389532 343.75 -6.19682765e-01 2.06482480e+00 2.15580801e+00 1.86235768 0.91072925 344.00 -6.05110540e-01 2.30155653e+00 2.37977336e+00 1.82789157 0.91125463 344.25 -5.70933525e-01 2.50016034e+00 2.56452078e+00 1.79530538 0.93361366 344.50 -3.07578748e-01 2.92851685e+00 2.94462487e+00 1.67544152 0.92097222 344.75 -2.13371208e-02 3.14516377e+00 3.14523615e+00 1.57758033 0.95959843 345.00 4.05292530e-01 3.26123656e+00 3.28632408e+00 1.44715453 0.94463689 345.25 6.73133314e-01 3.18283839e+00 3.25323972e+00 1.36237905 0.96265023 345.50 7.66463238e-01 3.01951352e+00 3.11527331e+00 1.32220996 0.95801097 345.75 7.88955036e-01 2.92593596e+00 3.03043747e+00 1.30741826 0.96354652 346.00 8.96776177e-01 2.91057271e+00 3.04559370e+00 1.27191599 0.96211209 346.25 9.13783964e-01 2.87347301e+00 3.01526919e+00 1.26290248 0.97036292 346.50 7.74696401e-01 2.77699789e+00 2.88303170e+00 1.29874390 0.97042639 346.75 6.94385275e-01 2.76792758e+00 2.85369830e+00 1.32500061 0.97109788 347.00 4.81474071e-01 2.94761889e+00 2.98668284e+00 1.40888284 0.94090255 347.25 2.81193896e-01 3.05816538e+00 3.07106586e+00 1.47910559 0.94108408 347.50 8.29528167e-03 3.39751958e+00 3.39752971e+00 1.56835476 0.94905303 347.75 -1.17512572e-01 3.64161522e+00 3.64351076e+00 1.60305449 0.95333857 348.00 -3.64090166e-01 4.10162559e+00 4.11775353e+00 1.65933156 0.93156441 348.25 -3.47379825e-01 4.54123280e+00 4.55449977e+00 1.64714226 0.92527571 348.50 -4.14235733e-01 5.51425070e+00 5.52978770e+00 1.64577644 0.91371502 348.75 -3.25308872e-01 6.16834863e+00 6.17692081e+00 1.62348592 0.93190791 349.00 2.10722522e-02 6.94357331e+00 6.94360529e+00 1.56776155 0.91178022 349.25 5.09661437e-01 7.67133481e+00 7.68824639e+00 1.50445669 0.92395415 349.50 1.51451435e+00 7.98731669e+00 8.12963601e+00 1.38340608 0.91701215 349.75 2.00209405e+00 8.10947110e+00 8.35295769e+00 1.32875305 0.90487696 350.00 2.98808319e+00 8.39556929e+00 8.91146592e+00 1.22886450 0.93016096 350.25 3.72614997e+00 8.85320905e+00 9.60538932e+00 1.17241944 0.93624819 350.50 4.55852454e+00 9.00169255e+00 1.00901246e+01 1.10203587 0.95431343 350.75 4.85695623e+00 8.75636641e+00 1.00131901e+01 1.06436932 0.93590535 351.00 5.34690766e+00 9.06216839e+00 1.05219921e+01 1.03774353 0.92133326 351.25 6.69053072e+00 9.28053033e+00 1.14407799e+01 0.94616687 0.90669273 351.50 8.79537052e+00 9.07364804e+00 1.26368363e+01 0.80097009 0.90203877 351.75 9.80882367e+00 7.55675813e+00 1.23821491e+01 0.65643237 0.83308545 352.00 1.10901449e+01 5.95279851e+00 1.25867837e+01 0.49262501 0.82046085 352.25 1.14352798e+01 4.60146727e+00 1.23263590e+01 0.38256691 0.80195814 352.50 1.19093184e+01 1.82072198e+00 1.20476924e+01 0.15170746 0.81097716 352.75 1.13833897e+01 -3.63499967e-01 1.13891919e+01 -0.03192164 0.79541552 353.00 1.03540351e+01 -2.64978544e+00 1.06877222e+01 -0.25054088 0.82126350 353.25 8.07120705e+00 -3.89249597e+00 8.96079841e+00 -0.44936276 0.67615266 353.50 4.32628907e+00 -6.98504783e+00 8.21630514e+00 -1.01625994 0.56190434 353.75 4.80509826e-01 -5.80823726e+00 5.82807942e+00 -1.48825526 0.28424691 354.00 -6.10861750e+00 -3.42543960e+00 7.00348800e+00 -2.63052954 0.32088602 354.25 -7.92709606e+00 1.02463632e+00 7.99304269e+00 3.01304792 0.43513221 354.50 -9.04173364e+00 4.84888700e+00 1.02598564e+01 2.64934521 0.56931034 354.75 -7.26870182e+00 1.14764844e+01 1.35846870e+01 2.13538199 0.58551883 355.00 -3.77810790e+00 1.79422177e+01 1.83356831e+01 1.77833519 0.71809913 355.25 7.44128079e+00 1.66592246e+01 1.82456138e+01 1.15070983 0.68852827 355.50 1.45653348e+01 1.25661116e+01 1.92368432e+01 0.71184453 0.72014847 355.75 1.38276411e+01 1.32534540e+00 1.38910114e+01 0.09555564 0.58480236 356.00 1.07078848e+01 -3.15521522e+00 1.11630722e+01 -0.28655311 0.69157012 356.25 5.02713385e+00 -4.75788992e+00 6.92167547e+00 -0.75788918 0.57506736 356.50 1.84421017e+00 -4.05172184e+00 4.45169193e+00 -1.14365382 0.56258493 356.75 -2.16537911e-01 -2.61970587e+00 2.62863986e+00 -1.65326619 0.52295197 357.00 -9.48205140e-01 -1.85320645e+00 2.08169813e+00 -2.04372560 0.59551174 357.25 -1.73932309e+00 -8.37367820e-01 1.93039625e+00 -2.69290853 0.63314738 357.50 -2.10256336e+00 -2.92637778e-01 2.12283056e+00 -3.00329964 0.71082777 357.75 -2.53538468e+00 -1.13569001e-01 2.53792699e+00 -3.09682898 0.54957775 358.00 -3.40322633e+00 9.28811878e-01 3.52769627e+00 2.87516031 0.47898281 358.25 -3.86099420e+00 4.49032324e+00 5.92201646e+00 2.28097979 0.82462915 358.50 -3.42512077e+00 5.15818800e+00 6.19179745e+00 2.15696180 0.90327254 358.75 -2.37784123e+00 5.78645236e+00 6.25596994e+00 1.96069159 0.95426044 359.00 -1.91088776e+00 5.92462800e+00 6.22516739e+00 1.88279525 0.95718449 359.25 -6.82955190e-01 6.58322218e+00 6.61855287e+00 1.67416832 0.95341235 359.50 4.55854126e-02 6.85868437e+00 6.85883586e+00 1.56415005 0.95985013 359.75 1.38310731e+00 6.03890782e+00 6.19527187e+00 1.34564684 0.95992169 360.00 1.75035256e+00 5.41394890e+00 5.68986615e+00 1.25809896 0.96145746 360.25 2.15814451e+00 4.39312548e+00 4.89460307e+00 1.11416922 0.95995491 360.50 2.31862596e+00 3.85910457e+00 4.50207890e+00 1.02977434 0.94850310 360.75 2.65239453e+00 2.83602384e+00 3.88306940e+00 0.81884329 0.92686338 361.00 2.75724629e+00 2.03330347e+00 3.42589114e+00 0.63541407 0.85110844 361.25 2.20500796e+00 4.83222779e-01 2.25733568e+00 0.21573736 0.62875799 361.50 8.04888721e-01 -1.57396846e-02 8.05042602e-01 -0.01955261 0.12348992 361.75 -9.15137475e-01 8.31796099e-01 1.23667350e+00 2.40386558 0.35162166 362.00 -7.97385520e-01 1.43921707e+00 1.64534782e+00 2.07673687 0.64596462 362.25 -8.00452499e-01 1.52153802e+00 1.71924465e+00 2.05509051 0.80414004 362.50 -9.28071133e-01 1.72527180e+00 1.95905048e+00 2.06432360 0.81729333 362.75 -8.60438589e-01 2.04486474e+00 2.21851896e+00 1.96908734 0.93264929 363.00 -6.86737566e-01 2.10895288e+00 2.21794742e+00 1.88559761 0.92580411 363.25 -4.63629968e-01 2.26154946e+00 2.30858370e+00 1.77300016 0.94498692 363.50 -1.99413089e-01 2.15468839e+00 2.16389640e+00 1.66308190 0.94307632 363.75 -1.37429457e-02 1.86984322e+00 1.86989372e+00 1.57814598 0.95668112 364.00 -2.71811038e-02 1.63183898e+00 1.63206534e+00 1.58745152 0.95923564 364.25 -1.20096032e-01 1.46597055e+00 1.47088161e+00 1.65253633 0.96374409 364.50 -3.06874839e-01 1.29062672e+00 1.32660827e+00 1.80423355 0.92146419 364.75 -5.60149915e-01 1.13580219e+00 1.26641800e+00 2.02896952 0.92610462 365.00 -7.27651139e-01 1.17872770e+00 1.38523470e+00 2.12385323 0.92188400 365.25 -8.14964118e-01 1.22913195e+00 1.47476502e+00 2.15628422 0.95337229 365.50 -9.07496405e-01 1.22135478e+00 1.52159694e+00 2.20981808 0.95196295 365.75 -9.40128479e-01 1.20919179e+00 1.53166130e+00 2.23165705 0.95829849 366.00 -9.79717059e-01 1.24425022e+00 1.58366793e+00 2.23780422 0.92316334 366.25 -1.05585860e+00 1.39006441e+00 1.74559917e+00 2.22039752 0.95042163 366.50 -1.12476185e+00 1.45702145e+00 1.84065226e+00 2.22820415 0.97174935 366.75 -1.12313079e+00 1.49371912e+00 1.86885515e+00 2.21551377 0.98136962 367.00 -1.06856643e+00 1.51530433e+00 1.85417945e+00 2.18499217 0.97622022 367.25 -1.06805838e+00 1.53212342e+00 1.86765920e+00 2.17957998 0.97792796 367.50 -1.12192624e+00 1.56128154e+00 1.92258121e+00 2.19389223 0.96797776 367.75 -1.17207349e+00 1.66468423e+00 2.03591008e+00 2.18425635 0.96935729 368.00 -1.00423188e+00 1.90001224e+00 2.14907612e+00 2.05701415 0.95312677 368.25 -8.49977756e-01 1.95925036e+00 2.13567885e+00 1.98012058 0.96199511 368.50 -8.13723635e-01 1.79723400e+00 1.97286498e+00 1.99594678 0.96559542 368.75 -8.29245804e-01 1.79349070e+00 1.97591940e+00 2.00388458 0.95902417 369.00 -9.38475609e-01 1.88848365e+00 2.10881648e+00 2.03199827 0.94117263 369.25 -7.91129627e-01 2.02076782e+00 2.17011259e+00 1.94395329 0.93724449 369.50 -8.16882440e-01 2.13608235e+00 2.28695097e+00 1.93605703 0.93820428 369.75 -8.71929548e-01 2.18959163e+00 2.35681408e+00 1.94976348 0.93865495 370.00 -5.34775029e-01 2.28244313e+00 2.34425489e+00 1.80094424 0.92816325 370.25 -1.81439653e-01 2.26002971e+00 2.26730118e+00 1.65090649 0.94512351 370.50 -7.18676585e-02 2.04337327e+00 2.04463671e+00 1.60595292 0.96482281 370.75 -1.71613416e-01 1.97316753e+00 1.98061638e+00 1.65755158 0.96522225 371.00 -1.61601313e-01 2.00793596e+00 2.01442841e+00 1.65110454 0.97587596 371.25 -1.30983889e-01 2.10930413e+00 2.11336714e+00 1.63281484 0.97535194 371.50 -8.92201124e-02 2.27004657e+00 2.27179921e+00 1.61007932 0.97422821 371.75 7.76685314e-02 2.30638297e+00 2.30769036e+00 1.53713358 0.96335643 372.00 3.14872687e-01 2.28179554e+00 2.30341827e+00 1.43366897 0.96756336 372.25 5.21237777e-01 2.22284954e+00 2.28314452e+00 1.34046697 0.95294222 372.50 9.57356153e-01 2.10086036e+00 2.30871069e+00 1.14321473 0.94839339 372.75 1.17776271e+00 1.96105205e+00 2.28754238e+00 1.02995269 0.94450137 373.00 1.31551542e+00 1.60323662e+00 2.07387283e+00 0.88365750 0.92560505 373.25 1.23725154e+00 1.18355587e+00 1.71219037e+00 0.76322091 0.92964803 373.50 1.13285456e+00 9.63379637e-01 1.48709777e+00 0.70472630 0.95838781 373.75 9.98573016e-01 7.69410711e-01 1.26061132e+00 0.65649895 0.94748784 374.00 8.76226169e-01 6.45731807e-01 1.08845848e+00 0.63509439 0.97131244 374.25 7.89388852e-01 5.65329449e-01 9.70943946e-01 0.62149008 0.97369046 374.50 6.99876342e-01 4.94398427e-01 8.56887798e-01 0.61501387 0.96405697 374.75 6.00859457e-01 4.12546076e-01 7.28852764e-01 0.60167139 0.92794187 375.00 4.63085578e-01 3.59469447e-01 5.86230787e-01 0.66008955 0.90114782 375.25 3.05068494e-01 3.66768809e-01 4.77059897e-01 0.87697945 0.81044972 375.50 1.64071687e-01 4.14305494e-01 4.45610324e-01 1.19372897 0.83703798 375.75 9.51260368e-02 5.56762703e-01 5.64830657e-01 1.40157470 0.88455910 376.00 7.44661591e-02 7.07401489e-01 7.11310112e-01 1.46591541 0.90883310 376.25 1.91733465e-01 8.07937463e-01 8.30376219e-01 1.33779425 0.93668823 376.50 3.03074440e-01 8.66380040e-01 9.17860822e-01 1.23428457 0.96313909 376.75 4.47722581e-01 8.34653927e-01 9.47155049e-01 1.07844127 0.95269067 377.00 5.66536834e-01 7.75212810e-01 9.60166071e-01 0.93968737 0.95766146 377.25 6.61273009e-01 5.54900482e-01 8.63247669e-01 0.69815526 0.95063269 377.50 6.79018383e-01 4.33927749e-01 8.05828304e-01 0.56864005 0.95363769 377.75 5.95327632e-01 2.67437351e-01 6.52639048e-01 0.42221106 0.94150008 378.00 5.51235979e-01 2.00383531e-01 5.86527633e-01 0.34866539 0.95423082 378.25 4.33049217e-01 6.56993244e-02 4.38004596e-01 0.15056512 0.83103835 378.50 3.43665834e-01 -1.86106743e-03 3.43670873e-01 -0.00541529 0.84545448 378.75 2.05376131e-01 -5.11609293e-02 2.11652536e-01 -0.24413938 0.59452942 379.00 9.89543099e-02 -7.73876769e-02 1.25621686e-01 -0.66370246 0.37898510 379.25 -5.32037860e-02 -6.33460867e-02 8.27246610e-02 -2.26939204 0.19518446 379.50 -1.17145063e-01 -3.63453866e-02 1.22653793e-01 -2.84075011 0.38406782 379.75 -2.22488721e-01 4.62757337e-02 2.27250247e-01 2.93652503 0.63220733 380.00 -2.41156653e-01 1.08372212e-01 2.64388100e-01 2.71925018 0.72163895 380.25 -2.45119204e-01 1.88620176e-01 3.09291117e-01 2.48572547 0.83296361 380.50 -2.53015242e-01 2.01781608e-01 3.23624057e-01 2.46837325 0.85775724 380.75 -2.50115123e-01 2.23953104e-01 3.35726924e-01 2.41132476 0.88223341 381.00 -2.51789568e-01 2.16600675e-01 3.32135272e-01 2.43118092 0.87924640 381.25 -2.91734594e-01 1.91816131e-01 3.49145388e-01 2.55996156 0.90709966 381.50 -3.16404414e-01 1.88895409e-01 3.68501328e-01 2.60337736 0.88285708 381.75 -4.21932444e-01 2.12024086e-01 4.72208853e-01 2.67594131 0.89836249 382.00 -4.75559928e-01 2.43060996e-01 5.34074801e-01 2.66910066 0.87654018 382.25 -6.29165175e-01 3.12814873e-01 7.02639283e-01 2.68019527 0.91851497 382.50 -6.49904953e-01 4.23182216e-01 7.75538288e-01 2.56441309 0.91380332 382.75 -6.31199242e-01 6.11316878e-01 8.78704050e-01 2.37219482 0.93415370 383.00 -5.78841889e-01 7.31083695e-01 9.32491985e-01 2.24049186 0.92189547 383.25 -4.60615619e-01 8.70249729e-01 9.84632591e-01 2.05760147 0.94207735 383.50 -3.21866338e-01 8.60336140e-01 9.18572922e-01 1.92879260 0.94037215 383.75 -2.33756654e-01 7.91818661e-01 8.25602183e-01 1.85785735 0.96835136 384.00 -2.26745992e-01 7.67598219e-01 8.00387887e-01 1.85802459 0.95931656 384.25 -2.14515944e-01 7.44025921e-01 7.74333043e-01 1.85150138 0.96964946 384.50 -2.22351190e-01 7.46763402e-01 7.79163417e-01 1.86019056 0.96434239 384.75 -2.19553750e-01 7.75083075e-01 8.05579060e-01 1.84682990 0.97916167 385.00 -1.97146857e-01 7.85814687e-01 8.10167641e-01 1.81660505 0.96887286 385.25 -1.83173635e-01 7.98246731e-01 8.18993543e-01 1.79636123 0.96956741 385.50 -1.57080343e-01 8.38017279e-01 8.52611983e-01 1.75608906 0.94824074 385.75 -1.04582591e-01 9.17371365e-01 9.23313457e-01 1.68430872 0.96487194 386.00 -2.06850273e-02 9.50205675e-01 9.50430794e-01 1.59256189 0.96249464 386.25 5.99203122e-02 9.60074649e-01 9.61942709e-01 1.50846504 0.96482164 386.50 1.79598013e-01 9.12410094e-01 9.29918075e-01 1.37644190 0.92942560 386.75 2.84510512e-01 8.03532376e-01 8.52414518e-01 1.23049608 0.92907499 387.00 2.93592771e-01 6.72193008e-01 7.33512205e-01 1.15899998 0.92340312 387.25 2.73263791e-01 6.22656855e-01 6.79981366e-01 1.15723875 0.94076774 387.50 2.71842423e-01 5.80916946e-01 6.41375710e-01 1.13311255 0.91928375 387.75 2.68688931e-01 5.67679005e-01 6.28055089e-01 1.12872666 0.93890934 388.00 2.80407040e-01 5.22815803e-01 5.93265937e-01 1.07850107 0.93021377 388.25 2.86325429e-01 5.12753929e-01 5.87280889e-01 1.06152146 0.94553534 388.50 2.62190474e-01 5.09431113e-01 5.72943194e-01 1.09547929 0.93864933 388.75 2.67691208e-01 4.77796702e-01 5.47675333e-01 1.06010878 0.93761689 389.00 2.57903781e-01 3.84623115e-01 4.63086710e-01 0.98011949 0.91292937 389.25 2.48524391e-01 3.55110461e-01 4.33437207e-01 0.96017041 0.91936582 389.50 2.27549641e-01 3.32578649e-01 4.02973197e-01 0.97075466 0.88043756 389.75 1.75683847e-01 3.22535513e-01 3.67279146e-01 1.07203430 0.87713611 390.00 1.37671000e-01 3.23766459e-01 3.51821012e-01 1.16874190 0.90295286 390.25 1.23809299e-01 3.31441634e-01 3.53811106e-01 1.21329941 0.90044728 390.50 1.17351025e-01 3.40281229e-01 3.59948021e-01 1.23870358 0.89059841 390.75 1.16968074e-01 3.51031988e-01 3.70006739e-01 1.24915497 0.91367156 391.00 1.21309032e-01 3.69719069e-01 3.89111901e-01 1.25375287 0.91678382 391.25 1.20084224e-01 3.66476313e-01 3.85648945e-01 1.25414911 0.90727484 391.50 1.01419097e-01 3.71540164e-01 3.85133648e-01 1.30431892 0.92259116 391.75 1.03140897e-01 3.61601611e-01 3.76023630e-01 1.29294121 0.90330714 392.00 9.90584053e-02 3.53272660e-01 3.66897997e-01 1.29741477 0.90294472 392.25 8.27520856e-02 3.71547721e-01 3.80651568e-01 1.35165057 0.89992334 392.50 7.33586216e-02 4.23166614e-01 4.29478138e-01 1.39914591 0.91938943 392.75 7.12347718e-02 4.34168415e-01 4.39973414e-01 1.40817349 0.90295081 393.00 1.28393047e-01 4.29129673e-01 4.47925273e-01 1.28007909 0.88775923 393.25 1.77573740e-01 4.18768383e-01 4.54861948e-01 1.16974072 0.88674592 393.50 2.57116829e-01 3.90985397e-01 4.67951540e-01 0.98908831 0.91105692 393.75 2.79859382e-01 3.40020080e-01 4.40380436e-01 0.88214741 0.86896625 394.00 2.93276463e-01 3.06683958e-01 4.24342001e-01 0.80774174 0.89109530 394.25 2.57866093e-01 2.47732428e-01 3.57583945e-01 0.76535794 0.82861102 394.50 1.82966640e-01 1.60942281e-01 2.43678496e-01 0.72144424 0.74714831 394.75 1.22956758e-01 1.96725974e-01 2.31990244e-01 1.01218596 0.68147868 395.00 8.98554005e-02 2.56260228e-01 2.71557172e-01 1.23355037 0.77332796 395.25 1.21185946e-01 3.33211824e-01 3.54564738e-01 1.22197759 0.74634042 395.50 1.69598536e-01 3.88294126e-01 4.23716877e-01 1.15899161 0.79058316 395.75 2.38250984e-01 3.45743425e-01 4.19883374e-01 0.96742491 0.74099546 396.00 3.18146229e-01 2.80600844e-01 4.24209685e-01 0.72277357 0.75194756 396.25 3.50375875e-01 1.48526547e-01 3.80556683e-01 0.40094392 0.71585084 396.50 3.35574306e-01 7.23425805e-02 3.43283504e-01 0.21232896 0.76763631 396.75 2.48717844e-01 5.27756726e-02 2.54255457e-01 0.20908967 0.71599763 397.00 2.05478750e-01 3.19001913e-02 2.07940229e-01 0.15401860 0.73079569 397.25 1.54300927e-01 -2.95139807e-02 1.57098221e-01 -0.18899268 0.43500769 397.50 8.28614836e-02 -6.61796425e-02 1.06046077e-01 -0.67393431 0.26586347 397.75 9.10943720e-03 -5.20291757e-02 5.28206112e-02 -1.39746988 0.08649211 398.00 -3.68778212e-02 -2.87917735e-02 4.67861081e-02 -2.47871009 0.09673727 398.25 -6.82592237e-02 4.42378603e-02 8.13407026e-02 2.56656399 0.27516016 398.50 -6.76613996e-02 6.73938173e-02 9.54986472e-02 2.35817577 0.40774372 398.75 -4.89959377e-02 7.42154925e-02 8.89299794e-02 2.15429803 0.41759984 399.00 -5.41256088e-02 7.78405034e-02 9.48088894e-02 2.17838786 0.53043726 399.25 -4.03981530e-02 1.07966943e-01 1.15277367e-01 1.92884044 0.58312111 399.50 -4.08594759e-02 1.21082251e-01 1.27790486e-01 1.89624930 0.70488606 399.75 -6.28596260e-02 1.35137187e-01 1.49041578e-01 2.00618075 0.79641666 400.00 -6.33254729e-02 1.26849526e-01 1.41777705e-01 2.03381755 0.81689091 400.25 -4.80662521e-02 1.14619201e-01 1.24289685e-01 1.96787678 0.68701626 400.50 -4.89742685e-02 1.05190653e-01 1.16032549e-01 2.00652769 0.67861524 400.75 -5.70522375e-02 8.13016719e-02 9.93223019e-02 2.18268584 0.56243238 401.00 -7.56962972e-02 7.04238832e-02 1.03389810e-01 2.39226157 0.55854629 401.25 -1.06933505e-01 7.88071915e-02 1.32835793e-01 2.50648057 0.63937917 401.50 -1.22434914e-01 8.00238070e-02 1.46267282e-01 2.56268885 0.66347227 401.75 -1.71371495e-01 1.13209002e-01 2.05388577e-01 2.55779779 0.74648867 402.00 -2.03559778e-01 1.31457329e-01 2.42317173e-01 2.56818111 0.78847991 402.25 -2.38237735e-01 1.75379162e-01 2.95829459e-01 2.50701340 0.84436743 402.50 -2.37972283e-01 1.92461407e-01 3.06059145e-01 2.46153571 0.81452075 402.75 -1.81154408e-01 2.51738829e-01 3.10144092e-01 2.19456413 0.73344741 403.00 -1.68253306e-01 2.59147473e-01 3.08976678e-01 2.14664904 0.73435195 403.25 -1.37973480e-01 2.69430960e-01 3.02704019e-01 2.04407079 0.76308978 403.50 -1.13172015e-01 2.59583332e-01 2.83180881e-01 1.98192661 0.69656242 403.75 -1.15892192e-01 3.02863025e-01 3.24279219e-01 1.93626169 0.76251773 404.00 -7.82838440e-02 3.05141840e-01 3.15023654e-01 1.82192922 0.67733207 404.25 -6.00324725e-02 2.72091614e-01 2.78635504e-01 1.78795062 0.65188999 404.50 -6.47340180e-02 2.74890314e-01 2.82409592e-01 1.80207293 0.63612125 404.75 -9.42273031e-02 3.08479376e-01 3.22549701e-01 1.86725234 0.70632462 405.00 -6.01822405e-02 3.14735885e-01 3.20438105e-01 1.75973073 0.65095967 405.25 -2.68956791e-02 3.21284867e-01 3.22408659e-01 1.65431447 0.69394154 405.50 2.12681549e-02 3.17145228e-01 3.17857563e-01 1.50383534 0.64599042 405.75 7.54917799e-02 3.22857766e-01 3.31566201e-01 1.34109945 0.74018881 406.00 1.11555286e-01 2.64636151e-01 2.87187873e-01 1.17185817 0.70935083 406.25 1.15866762e-01 1.83525066e-01 2.17040448e-01 1.00765071 0.68697745 406.50 1.01277837e-01 1.36520946e-01 1.69985791e-01 0.93253273 0.51003801 406.75 6.90171014e-02 9.83295257e-02 1.20133492e-01 0.95879901 0.44086462 407.00 2.62613617e-02 6.69420572e-02 7.19089573e-02 1.19694555 0.18550146 407.25 -1.02686742e-02 4.37883529e-02 4.49762773e-02 1.80114101 0.10935468 407.50 -8.38608075e-02 6.62289175e-02 1.06859275e-01 2.47313418 0.32994516 407.75 -1.28796645e-01 9.54561311e-02 1.60313595e-01 2.50378718 0.58924083 408.00 -1.42435165e-01 1.09953739e-01 1.79937770e-01 2.48418689 0.57580693 408.25 -1.30418505e-01 1.26781418e-01 1.81885993e-01 2.37033463 0.60620402 408.50 -1.10271130e-01 1.77498378e-01 2.08962667e-01 2.12669553 0.55262159 408.75 -1.02985834e-01 2.15246702e-01 2.38615223e-01 2.01705976 0.65935345 409.00 -3.03519439e-02 2.05476440e-01 2.07706061e-01 1.71745077 0.38648764 409.25 -1.38327839e-02 1.88646974e-01 1.89153448e-01 1.64399163 0.45245738 409.50 9.33206207e-03 1.65323104e-01 1.65586280e-01 1.51440875 0.36333225 409.75 3.77721113e-02 1.40286065e-01 1.45282182e-01 1.30778308 0.33166172 410.00 1.35010441e-02 3.53292260e-02 3.78210577e-02 1.20577243 0.02433435 410.25 -3.07164784e-03 3.61240971e-02 3.62544537e-02 1.65562272 0.02183601 410.50 -6.22274893e-03 -6.06817621e-02 6.09999906e-02 -1.67298639 0.06085970 410.75 -4.32854896e-02 -7.75469439e-02 8.88096960e-02 -2.07990138 0.14417854 411.00 -7.57642515e-02 -8.88278198e-03 7.62831936e-02 -3.02488307 0.10324123 411.25 -6.16308484e-02 -2.39773634e-02 6.61307449e-02 -2.77056309 0.06605289 411.50 -1.47898456e-01 -1.94427083e-02 1.49170949e-01 -3.01088233 0.26579961 411.75 -1.48133165e-01 -4.91364710e-02 1.56069944e-01 -2.82130856 0.28569654 412.00 -9.14429430e-02 -1.06680779e-01 1.40508364e-01 -2.27943489 0.19017577 412.25 -1.14607151e-01 -1.27795195e-01 1.71657831e-01 -2.30184248 0.24243668 412.50 -2.52472540e-01 -1.84988237e-01 3.12990465e-01 -2.50925165 0.40326801 412.75 -3.54810068e-01 -1.73097911e-01 3.94782309e-01 -2.68770351 0.43430981 413.00 -4.87707736e-01 -1.27553049e-01 5.04111710e-01 -2.88578655 0.48029351 413.25 -5.40292202e-01 -2.20822262e-02 5.40743274e-01 -3.10074449 0.43866691 413.50 -5.95732091e-01 2.90684662e-01 6.62868235e-01 2.68763524 0.51307684 413.75 -5.50738618e-01 4.28063504e-01 6.97532357e-01 2.48087625 0.53205408 414.00 -3.10659565e-01 5.04887961e-01 5.92807911e-01 2.12239281 0.50202746 414.25 -1.54152478e-01 5.75564908e-01 5.95850610e-01 1.83248277 0.39345768 414.50 3.20424049e-01 6.96345321e-01 7.66530089e-01 1.13953290 0.38542807 414.75 4.72191667e-01 1.13531635e-01 4.85648435e-01 0.23595671 0.09035405 415.00 5.58076565e-01 -1.01968537e+00 1.16241461e+00 -1.07002633 0.35126564 415.25 -1.86658528e-01 -1.11958041e+00 1.13503378e+00 -1.73599871 0.43799512 415.50 -5.05898543e-01 -1.25968850e+00 1.35747871e+00 -1.95268648 0.69744366 415.75 -7.18382921e-01 -8.99114394e-01 1.15086086e+00 -2.24492078 0.59290986 416.00 -8.26298495e-01 -4.21291012e-01 9.27499499e-01 -2.67009351 0.61992007 416.25 -8.53013161e-01 -2.00166900e-01 8.76183908e-01 -2.91110422 0.55668015 416.50 -8.31979093e-01 -4.79821043e-02 8.33361562e-01 -3.08398422 0.63549162 416.75 -6.27581784e-01 1.33130727e-02 6.27722975e-01 3.12038255 0.53775562 417.00 -5.09559709e-01 4.12209503e-02 5.11224280e-01 3.06087319 0.50199363 417.25 -4.26906429e-01 7.68784354e-03 4.26975646e-01 3.12358634 0.30479180 417.50 -2.86233044e-01 -6.62468121e-02 2.93799244e-01 -2.91415361 0.25020301 417.75 -1.96019482e-01 -1.33292470e-01 2.37045397e-01 -2.54441871 0.14242655 418.00 -8.12596073e-02 -2.66950385e-01 2.79044140e-01 -1.86628461 0.21262158 418.25 -1.22570771e-02 -3.55972320e-01 3.56183279e-01 -1.60521540 0.20828891 418.50 1.22064056e-01 -4.78235950e-01 4.93567885e-01 -1.32089376 0.37217868 418.75 1.99559429e-01 -6.55148072e-01 6.84867112e-01 -1.27512286 0.38501530 419.00 3.89222115e-01 -8.57118961e-01 9.41353689e-01 -1.14453382 0.51553646 419.25 7.24591584e-01 -1.23447010e+00 1.43141517e+00 -1.04001602 0.42906230 419.50 8.10020494e-01 -1.68026925e+00 1.86532516e+00 -1.12158901 0.42623040 419.75 5.63158846e-01 -1.41267046e+00 1.52078457e+00 -1.19145565 0.18763651 420.00 -7.20665133e-01 -1.38040807e+00 1.55720412e+00 -2.05194108 0.18052243 420.25 -1.78832944e+00 -1.35660991e+00 2.24466314e+00 -2.49261619 0.50366905 420.50 -1.72477172e+00 -1.75970009e+00 2.46401743e+00 -2.34617082 0.62340020 420.75 -1.88665837e+00 -1.94425824e+00 2.70917329e+00 -2.34116009 0.63503906 421.00 -2.20222391e+00 -2.08899439e+00 3.03540569e+00 -2.38257470 0.68024297 421.25 -3.16580504e+00 -2.46893234e+00 4.01471648e+00 -2.47924406 0.82648525 421.50 -3.33609333e+00 -2.19649669e+00 3.99426044e+00 -2.55933230 0.84694825 421.75 -3.36975824e+00 -2.18001556e+00 4.01344471e+00 -2.56737490 0.85066654 422.00 -3.19479098e+00 -1.94154770e+00 3.73848858e+00 -2.59551388 0.85314591 422.25 -2.59611446e+00 -1.66410355e+00 3.08367491e+00 -2.57157195 0.89901817 422.50 -2.28282027e+00 -2.04475147e+00 3.06468220e+00 -2.41115119 0.90427567 422.75 -1.69818277e+00 -2.76423086e+00 3.24419434e+00 -2.12169464 0.91024385 423.00 -1.18816499e+00 -3.06865911e+00 3.29065416e+00 -1.94021414 0.84544664 423.25 2.92295863e-01 -3.69644130e+00 3.70797993e+00 -1.49188559 0.85498974 423.50 1.01171000e+00 -3.60737219e+00 3.74655725e+00 -1.29736461 0.78857878 423.75 3.00578777e+00 -3.86266508e+00 4.89437858e+00 -0.90951242 0.81101896 424.00 4.00034640e+00 -3.54164827e+00 5.34284978e+00 -0.72465378 0.81620430 424.25 4.76473371e+00 -1.88985851e+00 5.12584164e+00 -0.37760185 0.82712742 424.50 4.60958679e+00 -5.51948312e-01 4.64251412e+00 -0.11917184 0.80405355 424.75 4.48171891e+00 7.87599084e-01 4.55039742e+00 0.17395965 0.87275638 425.00 4.59232003e+00 1.64104687e+00 4.87672411e+00 0.34320403 0.89631358 425.25 4.95022536e+00 2.69157812e+00 5.63465383e+00 0.49801542 0.91250449 425.50 4.70036303e+00 2.93980815e+00 5.54399536e+00 0.55891766 0.89082837 425.75 4.65105549e+00 2.95689824e+00 5.51140312e+00 0.56629076 0.91564503 426.00 4.72038533e+00 3.02047154e+00 5.60404193e+00 0.56922676 0.87584228 426.25 4.97362915e+00 3.22911891e+00 5.92994063e+00 0.57584641 0.89581064 426.50 5.53050405e+00 2.20242385e+00 5.95291070e+00 0.37898134 0.88353572 426.75 5.48148159e+00 1.45039248e+00 5.67012158e+00 0.25867065 0.91679703 427.00 5.07884248e+00 7.14601908e-01 5.12886896e+00 0.13978411 0.89181384 427.25 4.90107528e+00 2.31997721e-01 4.90656314e+00 0.04730078 0.93142940 427.50 4.30847672e+00 -2.91843632e-01 4.31834973e+00 -0.06763376 0.92062172 427.75 3.87249681e+00 -5.90410604e-01 3.91724600e+00 -0.15129740 0.92514981 428.00 2.85493129e+00 -9.11143048e-01 2.99680068e+00 -0.30892908 0.85401628 428.25 2.20074341e+00 -9.85453893e-01 2.41130482e+00 -0.42100814 0.89900753 428.50 1.55301260e+00 -9.68134505e-01 1.83006354e+00 -0.55744164 0.82030147 428.75 1.03695915e+00 -8.97168621e-01 1.37120233e+00 -0.71324787 0.79238521 429.00 2.83673538e-01 -2.39150552e-01 3.71030541e-01 -0.70044449 0.14006251 429.25 -2.04227371e-01 1.41403170e-01 2.48402246e-01 2.53599837 0.10413658 429.50 -5.23906131e-01 8.14664742e-01 9.68584677e-01 2.14230149 0.52293220 429.75 -4.32619340e-01 1.57210490e+00 1.63054387e+00 1.83933432 0.79313281 430.00 2.76240413e-03 2.05042019e+00 2.05042205e+00 1.56944909 0.79671383 430.25 5.46782799e-01 2.17455870e+00 2.24224820e+00 1.32445774 0.82822731 430.50 1.11598940e+00 1.98041596e+00 2.27320912e+00 1.05763797 0.87943137 430.75 1.10968815e+00 1.76630975e+00 2.08596691e+00 1.00986170 0.87871997 431.00 8.69459058e-01 1.69835324e+00 1.90797347e+00 1.09764049 0.83544528 431.25 6.25602531e-01 1.74735165e+00 1.85596775e+00 1.22698672 0.79596784 431.50 4.51899872e-01 2.66471642e+00 2.70276286e+00 1.40280810 0.82584483 431.75 4.20001166e-01 2.99938826e+00 3.02865167e+00 1.43167200 0.85744490 432.00 1.49205375e+00 4.01974332e+00 4.28772209e+00 1.21537771 0.85125002 432.25 2.25787896e+00 3.82507896e+00 4.44176163e+00 1.03755234 0.82345041 432.50 3.85116510e+00 2.42521592e+00 4.55116961e+00 0.56199747 0.83338561 432.75 4.24423875e+00 1.71376603e+00 4.57717780e+00 0.38376628 0.83459035 433.00 3.58832354e+00 1.47156681e-01 3.59133971e+00 0.04098690 0.86797391 433.25 3.18039384e+00 -1.22420235e-02 3.18041741e+00 -0.00384920 0.88565773 433.50 2.52233263e+00 -4.19617210e-01 2.55699834e+00 -0.16485104 0.88534329 433.75 2.27819924e+00 -4.35850249e-01 2.31951659e+00 -0.18902937 0.87333847 434.00 1.75373179e+00 -5.60487491e-02 1.75462721e+00 -0.03194883 0.81076952 434.25 1.41653052e+00 8.21960568e-02 1.41891328e+00 0.05796133 0.73891452 434.50 1.10608165e+00 3.27571356e-01 1.15356821e+00 0.28792534 0.56826799 434.75 9.95904648e-01 5.91187925e-01 1.15815769e+00 0.53571438 0.46401609 435.00 1.20441219e+00 1.23141769e+00 1.72249768e+00 0.79648448 0.56047888 435.25 1.50019503e+00 1.44823705e+00 2.08518001e+00 0.76777774 0.57562845 435.50 1.58838069e+00 1.95055589e+00 2.51547640e+00 0.88738323 0.48174250 435.75 2.75504321e+00 2.23304990e+00 3.54637490e+00 0.68112981 0.37598798 436.00 1.60667693e+00 -3.57408674e-01 1.64595010e+00 -0.21888801 0.05550119 436.25 -2.00933622e+00 -2.01692027e+00 2.84699832e+00 -2.35431084 0.19523173 436.50 -3.37914846e+00 -1.99130633e+00 3.92223728e+00 -2.60908363 0.61778594 436.75 -2.97624955e+00 -9.92528838e-01 3.13738344e+00 -2.81970734 0.57701963 437.00 -3.19722196e+00 -4.98168634e-01 3.23579979e+00 -2.98702256 0.73498429 437.25 -3.39360265e+00 2.79117211e-02 3.39371743e+00 3.13336803 0.73610551 437.50 -3.89499452e+00 9.72984945e-01 4.01468331e+00 2.89679853 0.84904467 437.75 -3.74078692e+00 1.57642560e+00 4.05938473e+00 2.74276202 0.81667790 438.00 -3.49246020e+00 2.24314559e+00 4.15078069e+00 2.57066198 0.79791394 438.25 -3.22524296e+00 2.83369054e+00 4.29324985e+00 2.42072874 0.80299726 438.50 -3.14618215e+00 3.11640546e+00 4.42836822e+00 2.36094915 0.85203156 438.75 -2.75205989e+00 3.25050271e+00 4.25906110e+00 2.27334623 0.77625732 439.00 -2.43003250e+00 3.49906150e+00 4.26010438e+00 2.17780880 0.71420686 439.25 -2.42488226e+00 3.61176662e+00 4.35027725e+00 2.16205766 0.61509538 439.50 -3.06990028e+00 3.99842746e+00 5.04100286e+00 2.22557792 0.70809632 439.75 -4.42030257e+00 4.46299849e+00 6.28151497e+00 2.35138821 0.71543526 440.00 -5.53896041e+00 4.50183731e+00 7.13769022e+00 2.45912039 0.70472209 440.25 -5.78622550e+00 3.55882094e+00 6.79305616e+00 2.59018004 0.54389230 440.50 -6.58229011e+00 1.18379828e+00 6.68789365e+00 2.96364893 0.48078128 440.75 -5.16188045e+00 -3.08889431e+00 6.01550312e+00 -2.60234688 0.49348890 441.00 -3.15578512e+00 -5.01518594e+00 5.92545946e+00 -2.13244304 0.60566282 441.25 -7.27943408e-01 -4.47499910e+00 4.53381942e+00 -1.73205283 0.74304493 441.50 1.35440144e-01 -3.97170143e+00 3.97401010e+00 -1.53670825 0.77732033 441.75 5.51065343e-01 -3.62117994e+00 3.66287008e+00 -1.41977661 0.72281421 442.00 4.62968268e-01 -3.56986001e+00 3.59975556e+00 -1.44182808 0.67497115 442.25 7.70809549e-01 -2.85640740e+00 2.95858254e+00 -1.30722169 0.64710980 442.50 1.02699959e+00 -2.73392442e+00 2.92045731e+00 -1.21145563 0.71138579 442.75 -4.61142168e-01 -2.96221275e+00 2.99789200e+00 -1.72523162 0.64171958 443.00 -1.07564953e+00 -2.53742450e+00 2.75600164e+00 -1.97174668 0.71618909 443.25 -1.06311084e+00 -1.53223402e+00 1.86492513e+00 -2.17736974 0.77030348 443.50 -9.72191226e-01 -1.09168242e+00 1.46182294e+00 -2.29836248 0.73660949 443.75 -7.13412628e-01 -7.50024645e-01 1.03513021e+00 -2.33118188 0.50554740 444.00 -5.39327790e-01 -4.88208600e-01 7.27476531e-01 -2.40590278 0.32762742 444.25 -5.36912403e-01 -6.49133175e-02 5.40822214e-01 -3.02127548 0.23778684 444.50 -3.14348360e-01 1.15793583e-01 3.34997082e-01 2.78865540 0.09781333 444.75 -6.37784788e-02 3.07924374e-01 3.14460036e-01 1.77503226 0.14471451 445.00 1.55310817e-01 3.87229267e-01 4.17214520e-01 1.18935725 0.25210022 445.25 3.97417147e-01 3.88993848e-01 5.56108445e-01 0.77468751 0.52964960 445.50 4.55516503e-01 3.66045500e-01 5.84366831e-01 0.67692213 0.52549464 445.75 4.86673497e-01 3.33418838e-01 5.89931533e-01 0.60065417 0.66215338 446.00 4.66533858e-01 3.11901331e-01 5.61191840e-01 0.58930550 0.59751267 446.25 4.51253216e-01 3.92884578e-01 5.98320781e-01 0.71636218 0.69544704 446.50 4.37139246e-01 4.44033781e-01 6.23102495e-01 0.79322227 0.67433276 446.75 4.79656207e-01 5.75866885e-01 7.49461638e-01 0.87629674 0.75298598 447.00 5.25302529e-01 7.35653250e-01 9.03951575e-01 0.95069454 0.77074973 447.25 7.48641908e-01 9.55254956e-01 1.21366253e+00 0.90606816 0.82079283 447.50 1.13001604e+00 9.61672531e-01 1.48382961e+00 0.70508915 0.81044444 447.75 1.57114515e+00 8.58329178e-01 1.79031452e+00 0.50000425 0.88934895 448.00 1.88607216e+00 5.53509877e-01 1.96561476e+00 0.28545734 0.87270998 448.25 2.04787581e+00 -9.31387016e-02 2.04999272e+00 -0.04544932 0.84494638 448.50 1.62672595e+00 -8.97650324e-01 1.85795948e+00 -0.50423493 0.80041088 448.75 1.20293506e+00 -1.09684060e+00 1.62791648e+00 -0.73929832 0.85458747 449.00 7.24027347e-01 -1.01706032e+00 1.24844996e+00 -0.95214003 0.74668895 449.25 4.55142875e-01 -9.62613862e-01 1.06479129e+00 -1.12912836 0.75547344 449.50 3.60399596e-01 -6.84262309e-01 7.73371047e-01 -1.08601914 0.56766773 449.75 4.26936854e-01 -3.86962573e-01 5.76207524e-01 -0.73632308 0.38548069 450.00 4.49256965e-01 -3.33306821e-01 5.59397227e-01 -0.63830134 0.38449486 450.25 3.95388053e-01 -2.42206849e-01 4.63676471e-01 -0.54961825 0.47524948 450.50 4.16114252e-01 -2.06258492e-01 4.64428289e-01 -0.46018367 0.53284766 450.75 4.67574025e-01 -1.96604668e-01 5.07226640e-01 -0.39803439 0.59663572 451.00 5.30988295e-01 -2.78729134e-01 5.99698674e-01 -0.48338836 0.71889662 451.25 5.07081973e-01 -2.85213047e-01 5.81789146e-01 -0.51235866 0.73133900 451.50 5.73828999e-01 -3.40977873e-01 6.67492045e-01 -0.53615506 0.79382518 451.75 6.04381118e-01 -4.03051703e-01 7.26448354e-01 -0.58815260 0.84035567 452.00 5.20202607e-01 -4.89077202e-01 7.14007886e-01 -0.75456871 0.73875655 452.25 4.73313310e-01 -4.94341937e-01 6.84397136e-01 -0.80712627 0.68064803 452.50 3.45949952e-01 -4.19458303e-01 5.43715585e-01 -0.88114262 0.57418549 452.75 3.55015417e-01 -4.48527058e-01 5.72024884e-01 -0.90125128 0.56151430 453.00 5.34676010e-01 -4.82975592e-01 7.20516383e-01 -0.73463815 0.63292270 453.25 5.50306748e-01 -4.75363722e-01 7.27191986e-01 -0.71246043 0.60280278 453.50 6.36821181e-01 -6.95455745e-01 9.42973971e-01 -0.82938057 0.61851431 453.75 7.28635117e-01 -8.31816105e-01 1.10581516e+00 -0.85142458 0.65128047 454.00 6.30640410e-01 -1.15278326e+00 1.31400783e+00 -1.07021392 0.60617322 454.25 3.90706067e-01 -1.48110174e+00 1.53176813e+00 -1.31287760 0.57294287 454.50 -3.60573803e-01 -1.88845813e+00 1.92257317e+00 -1.75946108 0.33373700 454.75 -1.59380202e+00 -1.34354932e+00 2.08454544e+00 -2.44118597 0.40215105 455.00 -1.74224439e+00 -1.72555986e+00 2.45213628e+00 -2.36100572 0.71750372 455.25 -2.02372522e+00 -1.30918513e+00 2.41027581e+00 -2.56738680 0.74387418 455.50 -2.23638473e+00 -8.08248403e-01 2.37795756e+00 -2.79479075 0.79165409 455.75 -2.22818600e+00 -7.34928932e-01 2.34625945e+00 -2.82299584 0.72639990 456.00 -2.17382607e+00 -4.43603640e-01 2.21862659e+00 -2.94029071 0.77677520 456.25 -2.29575551e+00 -4.19534983e-01 2.33377440e+00 -2.96084334 0.78573551 456.50 -2.33567437e+00 -2.20178189e-01 2.34602924e+00 -3.04760290 0.82754598 456.75 -2.60321647e+00 -1.39208288e-01 2.60693593e+00 -3.08816805 0.82945188 457.00 -2.91954126e+00 -1.72659423e-02 2.91959232e+00 -3.13567880 0.85807270 457.25 -2.94359429e+00 3.46657406e-01 2.96393635e+00 3.02436590 0.83868124 457.50 -3.09717655e+00 6.73366806e-01 3.16953079e+00 2.92751114 0.90149481 457.75 -3.10388806e+00 1.04122800e+00 3.27387795e+00 2.81792999 0.88230011 458.00 -3.05217706e+00 1.48228446e+00 3.39307413e+00 2.68949222 0.90585348 458.25 -2.72557699e+00 1.85740242e+00 3.29828951e+00 2.54341062 0.91898897 458.50 -2.60826435e+00 2.00616651e+00 3.29055420e+00 2.48594296 0.95436110 458.75 -2.39824094e+00 2.19637572e+00 3.25201874e+00 2.40010141 0.94072887 459.00 -2.14322335e+00 2.28994377e+00 3.13643887e+00 2.32311049 0.94599425 459.25 -2.02189994e+00 2.31903230e+00 3.07668493e+00 2.28785212 0.93825339 459.50 -1.98616527e+00 2.30910426e+00 3.04578643e+00 2.28115088 0.95971143 459.75 -1.80917545e+00 2.33164330e+00 2.95121607e+00 2.23068273 0.95118921 460.00 -1.70098935e+00 2.40648542e+00 2.94695383e+00 2.18609517 0.95568823 460.25 -1.86681602e+00 2.34175534e+00 2.99479884e+00 2.24381944 0.95101165 460.50 -1.98413617e+00 2.34380893e+00 3.07086904e+00 2.27328028 0.95703683 460.75 -1.75363525e+00 2.63858898e+00 3.16818377e+00 2.15737442 0.92136285 461.00 -1.71596993e+00 2.77907759e+00 3.26616366e+00 2.12395541 0.94242255 461.25 -1.68123863e+00 2.91685242e+00 3.36668849e+00 2.09367307 0.91358900 461.50 -1.64687956e+00 3.04819949e+00 3.46464030e+00 2.06614593 0.91895792 461.75 -1.56134158e+00 3.57484047e+00 3.90093218e+00 1.98258413 0.89866380 462.00 -1.13789828e+00 3.84220875e+00 4.00716615e+00 1.85872402 0.89495121 462.25 -1.40598058e-01 3.44930265e+00 3.45216694e+00 1.61153507 0.89045437 462.50 -1.23013356e-01 3.30290421e+00 3.30519417e+00 1.60802312 0.90995251 462.75 -6.07283369e-02 3.16138241e+00 3.16196563e+00 1.59000339 0.93090101 463.00 -1.07042817e-01 3.08834797e+00 3.09020248e+00 1.60544268 0.92498661 463.25 -8.51736495e-02 2.89849738e+00 2.89974854e+00 1.60017332 0.89658386 463.50 -1.21648415e-01 3.05990735e+00 3.06232450e+00 1.61053099 0.91816299 463.75 -2.65336467e-01 3.05371970e+00 3.06522551e+00 1.65746824 0.93537207 464.00 -2.57406037e-01 3.04862201e+00 3.05946957e+00 1.65503011 0.92645923 464.25 7.87841377e-02 3.30370114e+00 3.30464040e+00 1.54695361 0.92590751 464.50 2.23764541e-01 3.24284606e+00 3.25055705e+00 1.50190301 0.92731890 464.75 5.52986739e-01 3.26312545e+00 3.30964984e+00 1.40292584 0.92057178 465.00 7.09871984e-01 3.11823588e+00 3.19801708e+00 1.34695931 0.85774881 465.25 1.04459602e+00 2.25615899e+00 2.48624903e+00 1.13718638 0.79194584 465.50 7.87179012e-01 1.83779767e+00 1.99928764e+00 1.16611076 0.73326405 465.75 3.67253933e-01 1.77400739e+00 1.81162294e+00 1.36666055 0.75809436 466.00 2.51251011e-01 1.77976672e+00 1.79741388e+00 1.43055232 0.81575418 466.25 1.41116969e-01 1.64537455e+00 1.65141497e+00 1.48523983 0.85842875 466.50 -7.16099476e-02 1.58612661e+00 1.58774230e+00 1.61591338 0.82675568 466.75 -3.45624607e-01 1.54163374e+00 1.57990219e+00 1.79134321 0.86402888 467.00 -5.42377140e-01 1.72003825e+00 1.80352559e+00 1.87625600 0.89262574 467.25 -7.49360021e-01 1.89478297e+00 2.03758262e+00 1.94740522 0.95515695 467.50 -7.64029138e-01 2.02806385e+00 2.16720639e+00 1.93108140 0.95645511 467.75 -9.13230801e-01 2.10943002e+00 2.29862687e+00 1.97936265 0.95903601 468.00 -1.05139412e+00 2.21273810e+00 2.44982439e+00 2.01437132 0.96247615 468.25 -1.19487854e+00 2.34392218e+00 2.63091351e+00 2.04223522 0.97539401 468.50 -1.31612450e+00 2.53989696e+00 2.86063984e+00 2.04888215 0.97340015 468.75 -1.44013209e+00 2.73206881e+00 3.08839447e+00 2.05590495 0.98146572 469.00 -1.58535783e+00 2.83640339e+00 3.24939127e+00 2.08047157 0.97308907 469.25 -1.66157648e+00 2.93948035e+00 3.37659313e+00 2.08528143 0.97522031 469.50 -1.91782389e+00 3.27089372e+00 3.79167432e+00 2.10110389 0.96513766 469.75 -2.09636016e+00 3.64252728e+00 4.20270519e+00 2.09302396 0.97354218 470.00 -2.12076487e+00 4.04164497e+00 4.56426749e+00 2.05403019 0.97394741 470.25 -2.12744729e+00 4.29855849e+00 4.79621070e+00 2.03037257 0.97832920 470.50 -2.13040785e+00 4.98237272e+00 5.41873376e+00 1.97485785 0.96562715 470.75 -2.17095058e+00 5.42610731e+00 5.84428498e+00 1.95138336 0.98009912 471.00 -1.78560134e+00 5.86532801e+00 6.13110470e+00 1.86631542 0.96265328 471.25 -1.45240047e+00 6.43156256e+00 6.59351683e+00 1.79289482 0.96342030 471.50 -1.02916032e+00 7.43256672e+00 7.50348046e+00 1.70838778 0.96557437 471.75 -5.47820356e-01 7.84154085e+00 7.86065328e+00 1.64054432 0.97523061 472.00 9.63812412e-02 8.31844823e+00 8.31900657e+00 1.55921040 0.97389628 472.25 6.60012274e-01 8.41948175e+00 8.44531167e+00 1.49256523 0.97188056 472.50 1.92492324e+00 8.83628170e+00 9.04351722e+00 1.35630425 0.97527243 472.75 2.66346124e+00 9.19886357e+00 9.57669654e+00 1.28896104 0.98029420 473.00 4.04507545e+00 9.26145315e+00 1.01062926e+01 1.15900325 0.97284359 473.25 4.87172992e+00 8.90675251e+00 1.01520438e+01 1.07028208 0.96720052 473.50 6.03343034e+00 8.09390003e+00 1.00952216e+01 0.93022688 0.96560512 473.75 6.52577659e+00 7.87331870e+00 1.02261873e+01 0.87871157 0.96972602 474.00 7.96877424e+00 6.95564350e+00 1.05774448e+01 0.71761805 0.95991974 474.25 8.20860579e+00 6.07792595e+00 1.02138334e+01 0.63735032 0.96836765 474.50 8.17344984e+00 4.90488240e+00 9.53221662e+00 0.54049259 0.96831047 474.75 8.18564848e+00 4.16165801e+00 9.18282301e+00 0.47035222 0.96203483 475.00 7.77562721e+00 3.31732124e+00 8.45369734e+00 0.40325105 0.95742597 475.25 7.27324506e+00 2.75337933e+00 7.77696544e+00 0.36189047 0.94920909 475.50 6.88199246e+00 1.72468437e+00 7.09481194e+00 0.24555109 0.93168516 475.75 6.91699322e+00 1.50584126e+00 7.07900792e+00 0.21435706 0.92250942 476.00 7.15677043e+00 9.73913554e-01 7.22273291e+00 0.13525202 0.93952581 476.25 7.16677669e+00 7.46298095e-01 7.20552906e+00 0.10375905 0.91651617 476.50 7.01574760e+00 2.46669104e-01 7.02008262e+00 0.03514487 0.84703911 476.75 6.51740743e+00 1.04540128e-01 6.51824580e+00 0.01603876 0.84531328 477.00 5.37894780e+00 -5.43952173e-01 5.40638173e+00 -0.10078351 0.82665306 477.25 4.62802904e+00 -4.58632777e-01 4.65069853e+00 -0.09877644 0.79245932 477.50 4.30763399e+00 -2.74964639e-01 4.31640084e+00 -0.06374546 0.85397920 477.75 3.96460572e+00 -8.75888151e-02 3.96557314e+00 -0.02208910 0.86313370 478.00 3.66771766e+00 2.22632008e-01 3.67446838e+00 0.06062603 0.90371544 478.25 3.64552200e+00 6.12336411e-01 3.69659120e+00 0.16641601 0.89976631 478.50 3.76916339e+00 8.29911216e-01 3.85944883e+00 0.21672625 0.93059751 478.75 3.97793996e+00 8.46218758e-01 4.06695125e+00 0.20960342 0.94879823 479.00 4.22241605e+00 8.64353069e-01 4.30997721e+00 0.20191625 0.96261976 479.25 4.49904850e+00 6.10639410e-01 4.54029932e+00 0.13490200 0.96390083 479.50 4.56117710e+00 4.23919767e-01 4.58083448e+00 0.09267464 0.97167798 479.75 4.39366956e+00 3.05564412e-01 4.40428222e+00 0.06943472 0.97583294 480.00 4.29995562e+00 2.90472949e-01 4.30975555e+00 0.06745007 0.98453402 480.25 4.32736308e+00 2.75554693e-01 4.33612749e+00 0.06359142 0.98160318 480.50 4.37427691e+00 3.71738554e-01 4.39004420e+00 0.08477916 0.97851521 480.75 4.55189733e+00 5.64364024e-01 4.58675005e+00 0.12335484 0.96614154 481.00 4.77447334e+00 5.70859911e-01 4.80847967e+00 0.11900008 0.96322356 481.25 5.22899828e+00 1.24448153e-01 5.23047898e+00 0.02379512 0.94905669 481.50 5.43179393e+00 -1.76757860e-01 5.43466913e+00 -0.03252986 0.93891473 481.75 4.84395366e+00 -1.00059073e+00 4.94621763e+00 -0.20369991 0.89101550 482.00 4.30162336e+00 -1.20442458e+00 4.46705744e+00 -0.27300224 0.88522109 482.25 3.67001603e+00 -5.28379747e-01 3.70785690e+00 -0.14298950 0.87912022 482.50 3.47122011e+00 -1.09442744e-01 3.47294497e+00 -0.03151817 0.84524686 482.75 3.75870355e+00 1.41658842e+00 4.01678667e+00 0.36041979 0.76159423 483.00 4.35959147e+00 2.61300970e+00 5.08270179e+00 0.53995637 0.83651835 483.25 6.74030587e+00 2.45192997e+00 7.17242524e+00 0.34889019 0.70343092 483.50 9.46504921e+00 6.21471364e-01 9.48543004e+00 0.06556549 0.74428871 483.75 1.04283446e+01 -1.27945251e+00 1.05065394e+01 -0.12207979 0.73065084 484.00 9.79831667e+00 -2.69940468e+00 1.01633555e+01 -0.26882800 0.58580067 484.25 2.51122933e+00 -7.90192214e+00 8.29135974e+00 -1.26309048 0.34435424 484.50 -7.66107414e-01 -7.94971192e+00 7.98654119e+00 -1.66686885 0.38085558 484.75 -9.31417591e-01 -5.25242366e+00 5.33436904e+00 -1.74630284 0.52955702 485.00 -6.70243929e-03 -4.52588948e+00 4.52589444e+00 -1.57227724 0.59153710 485.25 1.04719018e+00 -5.37826569e+00 5.47926538e+00 -1.37849458 0.76661679 485.50 9.63325220e-01 -5.96344178e+00 6.04074775e+00 -1.41064136 0.80348658 485.75 -3.39742514e-01 -7.89084296e+00 7.89815343e+00 -1.61382504 0.78291358 486.00 -2.05150959e+00 -7.68503388e+00 7.95414592e+00 -1.83166198 0.71111951 486.25 -5.35297141e+00 -4.95685340e+00 7.29552593e+00 -2.39459701 0.66047263 486.50 -5.67261174e+00 -3.01844973e+00 6.42569550e+00 -2.65258874 0.67721851 486.75 -5.29973498e+00 -1.26817254e+00 5.44935340e+00 -2.90671930 0.80477539 487.00 -4.80307751e+00 -5.83736765e-01 4.83841938e+00 -3.02065187 0.82971418 487.25 -3.95043400e+00 -3.86065861e-03 3.95043589e+00 -3.14061538 0.85280769 487.50 -3.50858678e+00 5.47818513e-01 3.55109649e+00 2.98670669 0.80987975 487.75 -2.96610931e+00 9.21906705e-01 3.10607734e+00 2.84024501 0.83927332 488.00 -2.74806579e+00 1.07900604e+00 2.95230751e+00 2.76744543 0.83971301 488.25 -2.51707770e+00 1.16113470e+00 2.77198736e+00 2.70937927 0.83580493 488.50 -1.97346508e+00 1.34534906e+00 2.38841548e+00 2.54324132 0.76165852 488.75 -1.69168197e+00 1.39776260e+00 2.19443117e+00 2.45104565 0.78760049 489.00 -1.70897878e+00 1.39951169e+00 2.20890051e+00 2.45542295 0.77852332 489.25 -1.91460716e+00 1.58857883e+00 2.48783104e+00 2.44899342 0.85464081 489.50 -1.89578613e+00 2.15896376e+00 2.87317413e+00 2.29137940 0.80314561 489.75 -1.84697138e+00 2.79807177e+00 3.35268682e+00 2.15423008 0.83187434 490.00 -9.66111677e-01 3.08659604e+00 3.23426142e+00 1.87413875 0.81971931 490.25 -6.57422429e-01 3.59348801e+00 3.65313021e+00 1.75174354 0.89914072 490.50 -6.75295942e-02 3.88343090e+00 3.88401800e+00 1.58818373 0.88681682 490.75 5.31942173e-01 4.14151223e+00 4.17553422e+00 1.44305420 0.91961072 491.00 1.42258871e+00 3.74488157e+00 4.00598260e+00 1.20775812 0.88744698 491.25 2.26155681e+00 3.51339381e+00 4.17834600e+00 0.99886566 0.92927235 491.50 2.84542289e+00 2.99311565e+00 4.12979088e+00 0.81068896 0.93940724 491.75 3.15013128e+00 2.64484148e+00 4.11321207e+00 0.69842363 0.95966050 492.00 3.20982308e+00 1.94654050e+00 3.75392916e+00 0.54513574 0.96442187 492.25 3.18549067e+00 1.56430510e+00 3.54885915e+00 0.45647969 0.97094288 492.50 3.19518924e+00 1.15866573e+00 3.39878516e+00 0.34788030 0.96024967 492.75 3.11050848e+00 9.47606729e-01 3.25164904e+00 0.29571452 0.97705054 493.00 3.10087243e+00 6.76889067e-01 3.17389172e+00 0.21491855 0.97200769 493.25 3.07091500e+00 5.13739322e-01 3.11359069e+00 0.16575699 0.97268747 493.50 2.99786672e+00 2.78736674e-01 3.01079707e+00 0.09271179 0.97285885 493.75 2.95236815e+00 1.15887389e-01 2.95464170e+00 0.03923221 0.97523507 494.00 2.82618217e+00 -7.08476238e-03 2.82619105e+00 -0.00250683 0.97151684 494.25 2.73702770e+00 -1.56526234e-01 2.74149979e+00 -0.05712618 0.97367044 494.50 2.60926067e+00 -2.96407450e-01 2.62604239e+00 -0.11311336 0.97167089 494.75 2.53094599e+00 -4.38008339e-01 2.56856748e+00 -0.17136378 0.96630545 495.00 2.46612155e+00 -6.70608764e-01 2.55567440e+00 -0.26550844 0.97175571 495.25 2.34962357e+00 -7.27130179e-01 2.45956281e+00 -0.30011902 0.96849925 495.50 2.08220574e+00 -8.04435106e-01 2.23219546e+00 -0.36867356 0.95950419 495.75 1.95566982e+00 -8.61461316e-01 2.13699790e+00 -0.41492089 0.95446189 496.00 1.68818722e+00 -8.93087267e-01 1.90986412e+00 -0.48659432 0.95134423 496.25 1.57153028e+00 -8.62671554e-01 1.79273802e+00 -0.50202694 0.95099059 496.50 1.31438684e+00 -8.62903209e-01 1.57232780e+00 -0.58093546 0.94635087 496.75 1.15223730e+00 -7.08055253e-01 1.35240269e+00 -0.55101652 0.91165521 497.00 9.90317660e-01 -5.35881685e-01 1.12600988e+00 -0.49600077 0.89787037 497.25 9.74738696e-01 -4.27898756e-01 1.06452472e+00 -0.41365885 0.87192703 497.50 9.75555126e-01 -2.23213545e-01 1.00076575e+00 -0.22493474 0.88278824 497.75 9.64015095e-01 -8.05914552e-02 9.67377943e-01 -0.08340584 0.85363302 498.00 9.68092648e-01 9.41689571e-02 9.72661898e-01 0.09696760 0.89672551 498.25 9.79073274e-01 1.54367268e-01 9.91167861e-01 0.15637939 0.89459994 498.50 1.07235060e+00 2.60047131e-01 1.10343116e+00 0.23790934 0.93053768 498.75 1.18206047e+00 2.77444300e-01 1.21418380e+00 0.23053943 0.90927606 499.00 1.21795921e+00 2.62051479e-01 1.24583129e+00 0.21192546 0.94074972 499.25 1.16944544e+00 1.96618802e-01 1.18585901e+00 0.16657207 0.91710970 499.50 1.12630422e+00 2.29451333e-01 1.14943861e+00 0.20097045 0.91064950 499.75 1.13898652e+00 2.85676528e-01 1.17426632e+00 0.24574692 0.90034502 500.00 1.16929796e+00 3.82906331e-01 1.23039627e+00 0.31646147 0.91287828 500.25 1.10552678e+00 5.25112926e-01 1.22390075e+00 0.44343926 0.90995377 500.50 1.10928347e+00 6.77986377e-01 1.30006743e+00 0.54860908 0.93359422 500.75 1.13089842e+00 7.38377635e-01 1.35060460e+00 0.57841990 0.93489278 501.00 1.19516609e+00 7.02285130e-01 1.38622739e+00 0.53125540 0.92867215 501.25 1.26466252e+00 8.09078485e-01 1.50132585e+00 0.56914178 0.90743723 501.50 1.23581747e+00 9.35809576e-01 1.55015624e+00 0.64811820 0.92023348 501.75 1.37361782e+00 1.02791335e+00 1.71564325e+00 0.64242862 0.91805998 502.00 1.45704852e+00 1.09297239e+00 1.82142226e+00 0.64358280 0.93633990 502.25 1.42797175e+00 1.28626720e+00 1.92187061e+00 0.73323768 0.94720256 502.50 1.45547930e+00 1.44153194e+00 2.04852003e+00 0.78058380 0.96118663 502.75 1.58806957e+00 1.72761434e+00 2.34661805e+00 0.82745961 0.95551627 503.00 1.73131735e+00 1.96829398e+00 2.62138150e+00 0.84936524 0.96333114 503.25 2.00471042e+00 2.06845922e+00 2.88051860e+00 0.80104779 0.94199175 503.50 2.19218432e+00 2.09548813e+00 3.03261317e+00 0.76284984 0.94414159 503.75 2.64833024e+00 2.07681806e+00 3.36553507e+00 0.66503168 0.94735121 504.00 2.95947597e+00 2.09136791e+00 3.62385399e+00 0.61518734 0.96055684 504.25 2.93617243e+00 1.98756208e+00 3.54563274e+00 0.59506944 0.96436904 504.50 2.91840665e+00 1.95263973e+00 3.51139563e+00 0.58966967 0.97026427 504.75 2.94355548e+00 1.93867009e+00 3.52462205e+00 0.58240771 0.95287093 505.00 2.98155492e+00 2.04313082e+00 3.61442295e+00 0.60076252 0.94922283 505.25 3.31729853e+00 2.15955979e+00 3.95830368e+00 0.57707756 0.94656413 505.50 3.52458230e+00 2.29611936e+00 4.20652404e+00 0.57739990 0.92809022 505.75 3.79434386e+00 2.69069577e+00 4.65154695e+00 0.61682947 0.90771690 506.00 3.85627651e+00 2.45925646e+00 4.57370866e+00 0.56769990 0.88331853 506.25 3.86297521e+00 1.79718731e+00 4.26057035e+00 0.43545003 0.84155470 506.50 3.37974246e+00 1.37749553e+00 3.64967849e+00 0.38701868 0.76409430 506.75 2.22875527e+00 1.16203430e+00 2.51349831e+00 0.48060702 0.70369835 507.00 1.30899776e+00 2.06414931e+00 2.44421511e+00 1.00563824 0.66144296 507.25 5.15385343e-01 3.27523331e+00 3.31553545e+00 1.41471782 0.75416209 507.50 -8.12987571e-02 3.51669992e+00 3.51763952e+00 1.59391012 0.68310861 507.75 -9.51941225e-01 3.62212130e+00 3.74512414e+00 1.82779763 0.65800760 508.00 -1.54008329e+00 3.48459203e+00 3.80975566e+00 1.98695203 0.65968762 508.25 -2.52406052e+00 3.06633953e+00 3.97156388e+00 2.25949520 0.70156837 508.50 -2.39879329e+00 2.84605682e+00 3.72212959e+00 2.27112360 0.60556626 508.75 -2.50450651e+00 1.75127145e+00 3.05606030e+00 2.53137149 0.57022763 509.00 -2.52655318e+00 8.24832956e-01 2.65778486e+00 2.82603565 0.57276469 509.25 -2.40258863e+00 4.63990912e-02 2.40303663e+00 3.12228293 0.60130245 509.50 -2.22557831e+00 -5.10462430e-01 2.28336828e+00 -2.91613058 0.58362539 509.75 -1.80610399e+00 -1.02236059e+00 2.07538739e+00 -2.62650408 0.58632354 510.00 -9.73650657e-01 -1.08226116e+00 1.45577636e+00 -2.30341517 0.48187543 510.25 -4.62806644e-01 -1.39033608e+00 1.46534105e+00 -1.89213337 0.62352815 510.50 9.75621035e-02 -1.55895272e+00 1.56200255e+00 -1.50829601 0.66811176 510.75 4.74325920e-01 -1.60202360e+00 1.67076770e+00 -1.28294044 0.65309409 511.00 1.07007056e+00 -1.33407193e+00 1.71020435e+00 -0.89477098 0.44512355 511.25 1.16169365e+00 -1.11807020e+00 1.61233158e+00 -0.76626542 0.26170381 511.50 9.84617446e-01 -8.87671475e-01 1.32568177e+00 -0.73366498 0.13440164 511.75 9.73058567e-01 -9.89904946e-01 1.38807593e+00 -0.79398007 0.08897897 512.00 2.33644899e+00 -5.54242412e-01 2.40128685e+00 -0.23291068 0.23607735 512.25 2.02934290e+00 -2.24799024e-01 2.04175591e+00 -0.11032450 0.18219045 512.50 2.07374430e+00 -1.79341664e-01 2.08148477e+00 -0.08626741 0.18159220 512.75 3.02488503e+00 -5.48168599e-01 3.07415326e+00 -0.17927406 0.30745928 513.00 2.45261160e+00 -1.16664436e+00 2.71594601e+00 -0.44399838 0.28254108 513.25 2.85850321e+00 -1.29232214e+00 3.13705867e+00 -0.42459684 0.34400471 513.50 2.70480535e+00 -9.29341950e-01 2.86000847e+00 -0.33095228 0.30282033 513.75 2.21974496e+00 -9.38210129e-01 2.40987675e+00 -0.39989184 0.32878238 514.00 2.65540425e+00 1.87326354e-01 2.66200355e+00 0.07042865 0.54213962 514.25 2.41113579e+00 4.87843141e-01 2.45999323e+00 0.19963416 0.67360950 514.50 1.72243575e+00 5.24788135e-01 1.80060753e+00 0.29574292 0.70513392 514.75 1.47098691e+00 5.70305918e-01 1.57767276e+00 0.36986070 0.72357455 515.00 1.16484406e+00 7.15398529e-01 1.36698820e+00 0.55076495 0.73814114 515.25 1.05437882e+00 7.94642108e-01 1.32029193e+00 0.64583877 0.79810268 515.50 8.64679150e-01 8.30830012e-01 1.19914492e+00 0.76543682 0.80533027 515.75 7.30749463e-01 8.83970012e-01 1.14690791e+00 0.88000478 0.82631222 516.00 5.34118252e-01 1.07326065e+00 1.19882055e+00 1.10902295 0.86661105 516.25 4.95281637e-01 1.06695708e+00 1.17630834e+00 1.13619650 0.90188956 516.50 3.66512864e-01 1.12660437e+00 1.18472321e+00 1.25627027 0.95855890 516.75 3.08518027e-01 1.13927979e+00 1.18031429e+00 1.30633813 0.96686767 517.00 2.46557488e-01 1.19581877e+00 1.22097220e+00 1.36746272 0.95210666 517.25 2.61944044e-01 1.27725338e+00 1.30383698e+00 1.36851726 0.96586635 517.50 2.68869523e-01 1.32057557e+00 1.34766860e+00 1.36994139 0.97032425 517.75 3.05070199e-01 1.38310914e+00 1.41635403e+00 1.35370391 0.96239893 518.00 3.65767329e-01 1.52227794e+00 1.56560399e+00 1.33499010 0.95202592 518.25 5.42396975e-01 1.58370661e+00 1.67401348e+00 1.24083132 0.92544322 518.50 7.92594227e-01 1.46738262e+00 1.66775818e+00 1.07555353 0.91336100 518.75 9.42181085e-01 1.20658641e+00 1.53086772e+00 0.90783246 0.85093892 519.00 1.07549531e+00 8.27490092e-01 1.35699300e+00 0.65580428 0.85878070 519.25 1.03683126e+00 6.08461470e-01 1.20218319e+00 0.53069215 0.88456417 519.50 1.01120165e+00 4.29731736e-01 1.09872569e+00 0.40184639 0.93055856 519.75 9.33492795e-01 3.94623348e-01 1.01347737e+00 0.39995358 0.91986194 520.00 8.53374921e-01 4.01376876e-01 9.43054692e-01 0.43963983 0.92451685 520.25 8.17513567e-01 3.66962465e-01 8.96097028e-01 0.42191906 0.91060954 520.50 7.93604095e-01 3.43607534e-01 8.64796853e-01 0.40860271 0.93600602 520.75 7.74843627e-01 2.66202011e-01 8.19296135e-01 0.33092238 0.91670128 521.00 8.10907078e-01 1.76193639e-01 8.29827987e-01 0.21395410 0.92792681 521.25 8.41684993e-01 4.34602955e-02 8.42806279e-01 0.05158905 0.90520410 521.50 7.74814090e-01 -1.46533505e-01 7.88548630e-01 -0.18691330 0.88942804 521.75 5.74769960e-01 -2.51224500e-01 6.27275264e-01 -0.41206377 0.83901622 522.00 3.63385748e-01 -2.90018161e-01 4.64929818e-01 -0.67358132 0.75191630 522.25 2.11662452e-01 -1.64959356e-01 2.68351603e-01 -0.66202270 0.59200960 522.50 1.53584535e-01 -7.25670061e-02 1.69865181e-01 -0.44139761 0.42837135 522.75 1.38270281e-01 1.54608197e-02 1.39131979e-01 0.11135339 0.30435746 523.00 1.09952041e-01 7.31020150e-02 1.32035434e-01 0.58674638 0.30199158 523.25 8.67992014e-02 1.82766180e-01 2.02330368e-01 1.12741377 0.46630428 523.50 1.06107240e-01 2.58523609e-01 2.79451611e-01 1.18132641 0.72729613 523.75 1.80192267e-01 3.94849026e-01 4.34021896e-01 1.14266819 0.84954313 524.00 2.64884293e-01 4.46570537e-01 5.19219542e-01 1.03542719 0.90996884 524.25 3.95149054e-01 4.24572879e-01 5.80004228e-01 0.82127765 0.91318780 524.50 4.72451661e-01 3.94707721e-01 6.15633622e-01 0.69598364 0.93322710 524.75 5.86560655e-01 3.00722189e-01 6.59156458e-01 0.47374584 0.92846700 525.00 6.31194653e-01 2.52269129e-01 6.79739953e-01 0.38022126 0.94754050 525.25 6.75230257e-01 1.53053960e-01 6.92359310e-01 0.22290272 0.95510960 525.50 6.81244803e-01 1.16839939e-01 6.91191763e-01 0.16985687 0.95500297 525.75 7.04387268e-01 -2.13369706e-02 7.04710359e-01 -0.03028227 0.93116336 526.00 6.85743769e-01 -9.45734698e-02 6.92234539e-01 -0.13704918 0.93549742 526.25 6.42182758e-01 -2.26347842e-01 6.80905309e-01 -0.33887036 0.93311432 526.50 6.00117055e-01 -2.71576155e-01 6.58706374e-01 -0.42496305 0.92740413 526.75 4.85225025e-01 -3.22354834e-01 5.82542671e-01 -0.58639073 0.92334141 527.00 4.10549124e-01 -3.26917085e-01 5.24809836e-01 -0.67247603 0.90095078 527.25 3.02696520e-01 -3.28326775e-01 4.46568756e-01 -0.82599282 0.87767828 527.50 2.70596486e-01 -2.91951222e-01 3.98067801e-01 -0.82334070 0.87943892 527.75 2.39016311e-01 -2.57828879e-01 3.51574355e-01 -0.82324413 0.93128349 528.00 2.25094547e-01 -2.36777943e-01 3.26697642e-01 -0.81068849 0.91740165 528.25 1.93636836e-01 -2.09506721e-01 2.85286330e-01 -0.82474319 0.90729977 528.50 1.96059649e-01 -1.92277401e-01 2.74608786e-01 -0.77565887 0.89321556 528.75 1.94754010e-01 -1.56589290e-01 2.49898640e-01 -0.67719725 0.92211445 529.00 2.01042327e-01 -1.39932691e-01 2.44947290e-01 -0.60806058 0.91185595 529.25 2.26110350e-01 -1.14053296e-01 2.53247003e-01 -0.46717282 0.93437345 529.50 2.50054581e-01 -1.24983651e-01 2.79550007e-01 -0.46350798 0.94337733 529.75 2.35720021e-01 -1.59273872e-01 2.84485667e-01 -0.59422415 0.96709382 530.00 2.15870227e-01 -1.59933692e-01 2.68661015e-01 -0.63763799 0.95029675 530.25 2.02664942e-01 -1.43750467e-01 2.48469869e-01 -0.61694108 0.94964511 530.50 1.93727872e-01 -1.41962578e-01 2.40174649e-01 -0.63239787 0.95208553 530.75 1.87882814e-01 -1.41248763e-01 2.35055663e-01 -0.64464689 0.95392772 531.00 1.85663630e-01 -1.42062050e-01 2.33778976e-01 -0.65313199 0.93652747 531.25 1.83223874e-01 -1.37607636e-01 2.29143731e-01 -0.64416351 0.93084976 531.50 1.76275723e-01 -1.30417100e-01 2.19275513e-01 -0.63697159 0.90287176 531.75 1.60937497e-01 -1.18853156e-01 2.00067365e-01 -0.63610367 0.90718715 532.00 1.58309526e-01 -8.33434763e-02 1.78907912e-01 -0.48459008 0.88707057 532.25 1.68670348e-01 -6.17994582e-02 1.79635351e-01 -0.35120262 0.89066802 532.50 2.05099446e-01 -3.46361880e-02 2.08003482e-01 -0.16729664 0.86693980 532.75 2.52825277e-01 -2.41509588e-02 2.53976159e-01 -0.09523534 0.93112779 533.00 3.07361836e-01 -4.45002072e-02 3.10566525e-01 -0.14378209 0.93372959 533.25 3.42572514e-01 -6.36715299e-02 3.48439365e-01 -0.18376601 0.96232881 533.50 3.57812473e-01 -1.13464777e-01 3.75371844e-01 -0.30707631 0.94309708 533.75 3.63035802e-01 -1.56747206e-01 3.95429741e-01 -0.40758913 0.95426961 534.00 3.61222314e-01 -1.79921855e-01 4.03551030e-01 -0.46211985 0.96006538 534.25 3.52411989e-01 -1.93753363e-01 4.02162375e-01 -0.50268366 0.96678136 534.50 3.38775046e-01 -2.55362807e-01 4.24238960e-01 -0.64591772 0.95655418 534.75 3.20308268e-01 -2.82673806e-01 4.27202373e-01 -0.72306512 0.95995067 535.00 2.99117072e-01 -3.14889132e-01 4.34311165e-01 -0.81107965 0.95247012 535.25 2.78847235e-01 -3.35193734e-01 4.36016765e-01 -0.87690531 0.95748003 535.50 2.33298694e-01 -3.61242586e-01 4.30028471e-01 -0.99736324 0.92159607 535.75 1.93656053e-01 -3.69719821e-01 4.17367239e-01 -1.08829727 0.91637315 536.00 9.70033166e-02 -3.41217203e-01 3.54737682e-01 -1.29381754 0.86187273 536.25 5.82574486e-02 -3.13975425e-01 3.19334461e-01 -1.38733494 0.82533209 536.50 1.79947073e-02 -2.69485801e-01 2.70085924e-01 -1.50412107 0.82223044 536.75 9.64666251e-03 -2.43299462e-01 2.43490629e-01 -1.53116775 0.78910948 537.00 -1.63765097e-02 -1.62925485e-01 1.63746462e-01 -1.67097519 0.48136492 537.25 -1.73192565e-02 -1.13291534e-01 1.14607715e-01 -1.72249521 0.22365914 537.50 4.30116003e-02 -1.12367621e-02 4.44551750e-02 -0.25553815 0.02223389 537.75 7.01565679e-02 2.50116790e-02 7.44817300e-02 0.34246460 0.04907062 538.00 1.65852229e-01 1.36874838e-01 2.15038794e-01 0.68996774 0.13923037 538.25 2.73068527e-01 1.30618055e-02 2.73380744e-01 0.04779700 0.13077607 538.50 3.91032370e-01 -4.42507344e-01 5.90524397e-01 -0.84707451 0.29007062 538.75 2.08689525e-01 -5.44919018e-01 5.83513543e-01 -1.20505361 0.42954130 539.00 4.51946415e-02 -5.20530215e-01 5.22488526e-01 -1.48418928 0.60573338 539.25 2.94145924e-02 -4.31258669e-01 4.32260636e-01 -1.50269542 0.60191101 539.50 9.91077003e-03 -3.93940130e-01 3.94064778e-01 -1.54564357 0.70786034 539.75 7.90595772e-03 -3.51951447e-01 3.52040232e-01 -1.54833690 0.68626709 540.00 1.05904915e-02 -3.17210083e-01 3.17386823e-01 -1.53742236 0.69045669 540.25 4.47854648e-03 -3.06012562e-01 3.06045332e-01 -1.55616220 0.59486245 540.50 -5.67765702e-04 -2.46837131e-01 2.46837784e-01 -1.57309649 0.58555973 540.75 8.33438937e-03 -2.22713538e-01 2.22869428e-01 -1.53339177 0.56796894 541.00 1.82939775e-02 -2.17968611e-01 2.18734965e-01 -1.48706316 0.67466139 541.25 5.19792588e-02 -2.10916519e-01 2.17227120e-01 -1.32916662 0.63587564 541.50 7.61860150e-02 -1.96029375e-01 2.10313634e-01 -1.20011611 0.71990946 541.75 1.00746644e-01 -1.98937288e-01 2.22993118e-01 -1.10202263 0.66338297 542.00 1.29743784e-01 -1.96225368e-01 2.35239972e-01 -0.98658942 0.72991700 542.25 1.67192292e-01 -2.15917003e-01 2.73081334e-01 -0.91190128 0.69311325 542.50 1.89945082e-01 -2.72326828e-01 3.32025655e-01 -0.96175730 0.65891836 542.75 1.35550492e-01 -3.78776351e-01 4.02300211e-01 -1.22713280 0.55990937 543.00 -4.31051769e-02 -5.07582929e-01 5.09409939e-01 -1.65551549 0.67552364 543.25 -1.42754838e-01 -4.00631748e-01 4.25305468e-01 -1.91309414 0.63014328 543.50 -1.77076025e-01 -3.28866002e-01 3.73508722e-01 -2.06472433 0.63515203 543.75 -2.42104835e-01 -1.80812699e-01 3.02172108e-01 -2.50011934 0.72427501 544.00 -2.31984968e-01 -1.48838970e-01 2.75626675e-01 -2.57115311 0.81796186 544.25 -2.23070094e-01 -1.01716893e-01 2.45166460e-01 -2.71377173 0.76026504 544.50 -2.01336725e-01 -5.90872400e-02 2.09827974e-01 -2.85613305 0.72363811 544.75 -1.17585925e-01 -4.58129071e-02 1.26195373e-01 -2.77007326 0.49151739 545.00 -1.09164447e-01 -2.76581957e-02 1.12613730e-01 -2.89345164 0.48083751 545.25 -1.12717631e-01 -4.38032115e-02 1.20929673e-01 -2.77094354 0.49112420 545.50 -1.09416543e-01 -4.50922183e-02 1.18343940e-01 -2.75068598 0.51161629 545.75 -1.18218468e-01 -2.51436441e-02 1.20862769e-01 -2.93202743 0.41670434 546.00 -1.28594868e-01 -1.63901116e-02 1.29635165e-01 -3.01482076 0.43784330 546.25 -1.42534059e-01 1.00290960e-02 1.42886461e-01 3.07134563 0.50274074 546.50 -1.48052856e-01 3.72778111e-02 1.52673781e-01 2.89493265 0.48761342 546.75 -1.35056867e-01 1.03978889e-01 1.70446374e-01 2.48548319 0.43597389 547.00 -1.20348562e-01 1.30919983e-01 1.77830870e-01 2.31414709 0.47912309 547.25 -2.52757569e-02 1.83697036e-01 1.85427789e-01 1.70753253 0.54082403 547.50 -1.02776347e-02 1.77233216e-01 1.77530962e-01 1.62872078 0.54527645 547.75 4.50964753e-02 1.24064211e-01 1.32006138e-01 1.22215193 0.29169398 548.00 3.20741673e-02 1.00409605e-01 1.05407974e-01 1.26160757 0.14315744 548.25 -5.61288559e-03 1.17836794e-01 1.17970396e-01 1.61839306 0.21755750 548.50 2.17354184e-02 1.33182679e-01 1.34944635e-01 1.40902247 0.21948045 548.75 1.12236590e-01 2.21528823e-01 2.48338623e-01 1.10184643 0.29924617 549.00 1.78024081e-01 2.39491999e-01 2.98410776e-01 0.93157100 0.35684111 549.25 2.62510304e-01 2.80696502e-01 3.84320421e-01 0.81886499 0.45034403 549.50 2.82540259e-01 3.54748751e-01 4.53514801e-01 0.89822271 0.52246674 549.75 2.45139847e-01 4.70621632e-01 5.30639487e-01 1.09058049 0.62889158 550.00 4.03504076e-01 4.41025711e-01 5.97761840e-01 0.82979799 0.50520770 550.25 5.16537852e-01 3.43489702e-01 6.20319698e-01 0.58683717 0.71538143 550.50 5.15908588e-01 2.93548260e-01 5.93575818e-01 0.51730797 0.75990669 550.75 6.28421548e-01 2.78533884e-01 6.87382547e-01 0.41720789 0.84305049 551.00 6.78667892e-01 1.98258073e-01 7.07033501e-01 0.28421946 0.87027419 551.25 7.52725290e-01 1.24949210e-01 7.63025339e-01 0.16449584 0.92120233 551.50 7.68724922e-01 8.90882855e-02 7.73869968e-01 0.11537629 0.91528327 551.75 7.81255479e-01 5.00321358e-02 7.82855886e-01 0.06395335 0.91035866 552.00 8.34409207e-01 -8.12926764e-03 8.34448806e-01 -0.00974223 0.89567289 552.25 8.90363506e-01 -5.54715109e-02 8.92089829e-01 -0.06222167 0.94378160 552.50 9.09010933e-01 -1.46326046e-01 9.20712870e-01 -0.15960365 0.94850646 552.75 9.54818901e-01 -2.76373006e-01 9.94012662e-01 -0.28175067 0.96150273 553.00 9.61460991e-01 -4.38463722e-01 1.05672024e+00 -0.42786461 0.93782623 553.25 9.52408789e-01 -5.75763305e-01 1.11291773e+00 -0.54374651 0.93607838 553.50 7.67980985e-01 -7.12013098e-01 1.04726188e+00 -0.74759988 0.91538082 553.75 6.22386273e-01 -8.04209929e-01 1.01691606e+00 -0.91216747 0.92054724 554.00 4.65383704e-01 -8.11617333e-01 9.35577195e-01 -1.05016317 0.90928401 554.25 3.93228958e-01 -8.00705994e-01 8.92053307e-01 -1.11429178 0.93864516 554.50 3.40850651e-01 -6.93344389e-01 7.72596666e-01 -1.11388831 0.89216858 554.75 2.86290297e-01 -6.43179757e-01 7.04018703e-01 -1.15201045 0.88488060 555.00 2.37084570e-01 -6.07701267e-01 6.52311217e-01 -1.19882446 0.87409641 555.25 2.14976494e-01 -5.42907823e-01 5.83921054e-01 -1.19376686 0.86184641 555.50 2.31962653e-01 -5.22487125e-01 5.71663771e-01 -1.15297777 0.86485831 555.75 2.07542004e-01 -5.06313940e-01 5.47199680e-01 -1.18177808 0.86845749 556.00 2.89896344e-01 -4.56353925e-01 5.40646645e-01 -1.00486404 0.79815951 556.25 3.39794181e-01 -4.57129934e-01 5.69585693e-01 -0.93158364 0.80629656 556.50 4.10726368e-01 -5.93472951e-01 7.21738383e-01 -0.96541060 0.80499649 556.75 3.96759074e-01 -7.06556510e-01 8.10333181e-01 -1.05913714 0.84409280 557.00 2.89047329e-01 -8.54979858e-01 9.02518097e-01 -1.24478435 0.84212512 557.25 1.86380747e-01 -9.03142388e-01 9.22173496e-01 -1.36728413 0.85321661 557.50 -9.46669738e-02 -8.84792555e-01 8.89842515e-01 -1.67738425 0.81014524 557.75 -1.25889730e-01 -8.71043893e-01 8.80094136e-01 -1.71432987 0.82264046 558.00 -1.70207280e-01 -6.75317780e-01 6.96437091e-01 -1.81769433 0.81543852 558.25 -1.85405755e-01 -6.01530113e-01 6.29455138e-01 -1.86978050 0.77974291 558.50 -1.06580077e-01 -4.92657696e-01 5.04054479e-01 -1.78385004 0.73911642 558.75 -8.10355145e-02 -4.55235789e-01 4.62392018e-01 -1.74695890 0.70283982 559.00 -1.00614638e-01 -4.10101286e-01 4.22263389e-01 -1.81138522 0.64828762 559.25 -5.83038683e-02 -4.22110223e-01 4.26117802e-01 -1.70805259 0.62582591 559.50 -2.56408235e-02 -4.18376469e-01 4.19161450e-01 -1.63200625 0.55324022 559.75 1.13428817e-03 -4.18775096e-01 4.18776632e-01 -1.56808775 0.48404715 560.00 -5.46879575e-02 -5.83895509e-01 5.86450968e-01 -1.66418441 0.69863034 560.25 -6.24096778e-03 -5.87828448e-01 5.87861577e-01 -1.58141292 0.64206987 560.50 4.58097720e-02 -6.89407712e-01 6.90928019e-01 -1.50444585 0.64431541 560.75 -7.57805499e-02 -7.66168909e-01 7.69907454e-01 -1.66938408 0.57788237 561.00 -3.48215054e-01 -7.22579053e-01 8.02106110e-01 -2.01986410 0.54237072 561.25 -3.41723065e-01 -6.57860326e-01 7.41319675e-01 -2.04987962 0.45777608 561.50 -4.13133904e-01 -6.05286276e-01 7.32837703e-01 -2.16970984 0.33644099 561.75 -5.95639869e-01 -2.87400382e-01 6.61351520e-01 -2.69203716 0.31330136 562.00 -6.95490057e-01 -1.01403415e-01 7.02843561e-01 -2.99681144 0.46482516 562.25 -6.26026741e-01 1.30409532e-01 6.39465501e-01 2.93621672 0.41784342 562.50 -6.54264191e-01 1.90721250e-01 6.81495581e-01 2.85794759 0.40262848 562.75 -4.34486660e-01 2.38228061e-01 4.95511116e-01 2.64005729 0.36816082 563.00 -3.60422664e-01 2.77317375e-01 4.54763041e-01 2.48577646 0.40753944 563.25 -2.22655362e-01 2.59842207e-01 3.42189104e-01 2.27927498 0.34774001 563.50 -1.85765114e-01 2.47318040e-01 3.09313580e-01 2.21501279 0.33543803 563.75 -7.76285879e-02 1.86636759e-01 2.02137274e-01 1.96496306 0.22811274 564.00 -6.57979103e-02 1.75458377e-01 1.87389986e-01 1.92957209 0.29226779 564.25 -2.52530617e-02 1.06064394e-01 1.09029229e-01 1.80453625 0.15326602 564.50 -3.53823457e-02 6.61341343e-02 7.50042272e-02 2.06205720 0.10336994 564.75 -2.82605681e-02 4.15539063e-02 5.02532271e-02 2.16803735 0.05508642 565.00 -1.89537335e-02 1.61118022e-02 2.48763780e-02 2.43706402 0.01517084 565.25 -4.30755847e-02 7.34279174e-03 4.36969402e-02 2.97275257 0.04148219 565.50 -3.20964120e-02 3.66970978e-02 4.87530168e-02 2.28941718 0.05204685 565.75 -2.78828659e-02 1.31974639e-01 1.34887952e-01 1.77900880 0.23219134 566.00 1.69714724e-02 1.28282039e-01 1.29399816e-01 1.43926206 0.20393358 566.25 1.23593486e-01 4.16710368e-02 1.30429387e-01 0.32519246 0.19548786 566.50 1.97947029e-01 2.82108240e-02 1.99947185e-01 0.14156373 0.35491156 566.75 2.80122489e-01 -1.15926332e-01 3.03162536e-01 -0.39238153 0.59952069 567.00 2.49201041e-01 -1.87848082e-01 3.12070602e-01 -0.64592954 0.63054488 567.25 1.59447313e-01 -3.38798883e-01 3.74443759e-01 -1.13092343 0.75766499 567.50 7.24333962e-02 -3.90264714e-01 3.96929646e-01 -1.38728382 0.80841474 567.75 -4.71929505e-02 -4.04409865e-01 4.07154164e-01 -1.68696674 0.82042955 568.00 -1.20883661e-01 -3.88293917e-01 4.06675578e-01 -1.87260581 0.82608667 568.25 -2.19156351e-01 -3.53048055e-01 4.15538729e-01 -2.12633724 0.85717222 568.50 -2.87496717e-01 -3.33363685e-01 4.40210982e-01 -2.28245199 0.89007683 568.75 -3.15868080e-01 -3.06092894e-01 4.39847137e-01 -2.37190992 0.88486634 569.00 -3.57112616e-01 -2.76617322e-01 4.51715135e-01 -2.48253623 0.90306440 569.25 -3.83811710e-01 -2.10576022e-01 4.37782697e-01 -2.63979105 0.93496297 569.50 -3.97922931e-01 -1.65444842e-01 4.30946232e-01 -2.74756489 0.92561578 569.75 -4.24999799e-01 -1.01923299e-01 4.37050555e-01 -2.90621822 0.90987661 570.00 -4.26079098e-01 -8.46195509e-02 4.34400582e-01 -2.94554306 0.89034800 570.25 -4.59580228e-01 -7.44117798e-02 4.65565354e-01 -2.98107320 0.88167737 570.50 -5.32586688e-01 -4.49427171e-02 5.34479587e-01 -3.05740637 0.85290431 570.75 -6.50222473e-01 5.81467267e-02 6.52817207e-01 3.05240400 0.84685700 571.00 -6.54463330e-01 2.12011805e-01 6.87947131e-01 2.82831294 0.84496421 571.25 -6.48156675e-01 3.44679866e-01 7.34105773e-01 2.65284171 0.90266187 571.50 -7.14564303e-01 4.04922240e-01 8.21318552e-01 2.62604103 0.90992140 571.75 -7.32174156e-01 5.10667777e-01 8.92670473e-01 2.53256829 0.91498870 572.00 -6.75223997e-01 6.95085658e-01 9.69057025e-01 2.34170122 0.87550266 572.25 -5.89758238e-01 9.44475828e-01 1.11348524e+00 2.12898504 0.88828790 572.50 -5.04309303e-01 1.16452063e+00 1.26902962e+00 1.97947546 0.88060722 572.75 -2.44081145e-01 1.37004811e+00 1.39162044e+00 1.74710175 0.88206159 573.00 5.88990086e-02 1.36658532e+00 1.36785399e+00 1.52772358 0.85687000 573.25 3.76370994e-01 1.25230571e+00 1.30764090e+00 1.27884197 0.78130704 573.50 5.11640789e-01 9.83426287e-01 1.10855923e+00 1.09106965 0.78587035 573.75 5.43371000e-01 9.54994512e-01 1.09875683e+00 1.05349941 0.88792969 574.00 6.03551520e-01 9.27994763e-01 1.10699987e+00 0.99415229 0.83987085 574.25 6.96281883e-01 8.19474271e-01 1.07533555e+00 0.86649446 0.84740111 574.50 7.69634043e-01 8.38442390e-01 1.13812223e+00 0.82816130 0.83212536 574.75 8.76483064e-01 9.29901127e-01 1.27786489e+00 0.81496137 0.85686472 575.00 1.10659406e+00 9.17398755e-01 1.43741813e+00 0.69219273 0.83217242 575.25 1.29261049e+00 7.82821846e-01 1.51117568e+00 0.54453656 0.86725750 575.50 1.55211939e+00 7.28852772e-01 1.71473058e+00 0.43902134 0.85137812 575.75 1.73299591e+00 5.92292516e-01 1.83141619e+00 0.32932760 0.86634313 576.00 1.79805598e+00 3.79193298e-01 1.83760519e+00 0.20784513 0.81798064 576.25 1.93891470e+00 2.60971709e-01 1.95639885e+00 0.13379272 0.79783336 576.50 2.06119577e+00 -2.66426730e-01 2.07834338e+00 -0.12854559 0.72404840 576.75 2.16805771e+00 -9.27317516e-01 2.35804835e+00 -0.40417064 0.75691663 577.00 2.03982412e+00 -1.41257269e+00 2.48117796e+00 -0.60567282 0.79623754 577.25 1.56497025e+00 -1.69987988e+00 2.31056779e+00 -0.82669651 0.82073442 577.50 6.66668746e-01 -1.80099206e+00 1.92042173e+00 -1.21626908 0.83764094 577.75 4.41775541e-01 -1.63779761e+00 1.69633329e+00 -1.30732911 0.86601419 578.00 2.17855378e-01 -1.38048482e+00 1.39756907e+00 -1.41427637 0.87123794 578.25 1.57751155e-01 -1.20527250e+00 1.21555224e+00 -1.44065189 0.88373327 578.50 2.00025242e-01 -1.07224703e+00 1.09074460e+00 -1.38636847 0.90347922 578.75 2.48524700e-01 -1.06550368e+00 1.09410357e+00 -1.34164702 0.92744615 579.00 1.68040878e-01 -9.81741441e-01 9.96019073e-01 -1.40127302 0.91141293 579.25 1.39391143e-01 -1.00763951e+00 1.01723511e+00 -1.43333440 0.93264969 579.50 2.01666503e-01 -1.04750525e+00 1.06674113e+00 -1.38060258 0.90766804 579.75 1.57548632e-01 -1.01408034e+00 1.02624583e+00 -1.41666742 0.88567115 580.00 8.07070080e-02 -1.12550255e+00 1.12839249e+00 -1.49921132 0.87393233 580.25 -9.65791889e-03 -1.15866047e+00 1.15870072e+00 -1.57913155 0.88352088 580.50 -1.60431555e-01 -1.11933371e+00 1.13077241e+00 -1.71315452 0.91977896 580.75 -3.25045315e-01 -1.06203812e+00 1.11066621e+00 -1.86780166 0.90974595 581.00 -4.79263178e-01 -9.09536433e-01 1.02808060e+00 -2.05575610 0.93263545 581.25 -5.27411145e-01 -8.04803590e-01 9.62222082e-01 -2.15090866 0.92993840 581.50 -5.74644079e-01 -6.53088316e-01 8.69908136e-01 -2.29238763 0.92179784 581.75 -4.88481241e-01 -5.21858638e-01 7.14807919e-01 -2.32317069 0.88121025 582.00 -4.83692046e-01 -3.60350261e-01 6.03166897e-01 -2.50129965 0.85493298 582.25 -3.45227231e-01 -3.28820697e-01 4.76765028e-01 -2.38052999 0.83732615 582.50 -2.24307836e-01 -3.52220592e-01 4.17580353e-01 -2.13786387 0.83524046 582.75 -2.43494796e-01 -3.83103620e-01 4.53936228e-01 -2.13697092 0.82083613 583.00 -2.17606429e-01 -4.58526756e-01 5.07542455e-01 -2.01389979 0.85705684 583.25 -2.46049711e-01 -4.53945188e-01 5.16339708e-01 -2.06749621 0.86991185 583.50 -3.45173246e-01 -4.59612158e-01 5.74793794e-01 -2.21494341 0.86491030 583.75 -4.09764428e-01 -4.28020042e-01 5.92543705e-01 -2.33440759 0.82721772 584.00 -4.09850588e-01 -3.50386794e-01 5.39210914e-01 -2.43425297 0.80242452 584.25 -4.07023635e-01 -2.71474389e-01 4.89251043e-01 -2.55337696 0.81133446 584.50 -4.00643164e-01 -1.76335856e-01 4.37731971e-01 -2.72697524 0.77382897 584.75 -3.54111672e-01 -1.08168728e-01 3.70264163e-01 -2.84512965 0.58889660 585.00 -3.82503211e-01 -5.58382885e-02 3.86557397e-01 -2.99663534 0.48474721 585.25 -1.19720799e-01 8.42088665e-02 1.46370089e-01 2.52860378 0.08893209 585.50 6.39217610e-02 1.33574911e-01 1.48081897e-01 1.12445862 0.10000772 585.75 1.80789050e-01 1.91700794e-02 1.81802565e-01 0.10564088 0.10396727 586.00 2.12630661e-01 -2.76564458e-01 3.48854837e-01 -0.91535342 0.32726098 586.25 2.74680963e-01 -5.75566573e-01 6.37751136e-01 -1.12552538 0.53791363 586.50 2.15645884e-01 -7.12451204e-01 7.44372128e-01 -1.27688115 0.63188858 586.75 -1.43466819e-01 -7.50378994e-01 7.63970787e-01 -1.75970895 0.65161978 587.00 -3.95354122e-01 -8.84982970e-01 9.69277947e-01 -1.99093294 0.75643864 587.25 -7.25410741e-01 -7.33370914e-01 1.03152976e+00 -2.35073782 0.76672908 587.50 -9.28061304e-01 -6.06585838e-01 1.10871284e+00 -2.56268709 0.76913439 587.75 -1.03448073e+00 -1.69820164e-01 1.04832689e+00 -2.97888406 0.73399728 588.00 -8.56176215e-01 5.86495886e-02 8.58182664e-01 3.07319773 0.66908906 588.25 -5.00136992e-01 2.47201630e-01 5.57893947e-01 2.68254128 0.45035719 588.50 -3.30145413e-01 3.83692690e-01 5.06177908e-01 2.28132152 0.39286055 588.75 3.02324516e-02 5.53827467e-02 6.30971454e-02 1.07112013 0.00664803 589.00 1.68412581e-01 -1.12709695e-02 1.68789313e-01 -0.06682510 0.05850903 589.25 2.40638428e-01 -6.60299720e-02 2.49533185e-01 -0.26780362 0.07400692 589.50 2.25094147e-01 -2.28453029e-01 3.20715078e-01 -0.79280383 0.10503899 589.75 3.00858810e-01 -4.27929677e-01 5.23105948e-01 -0.95802186 0.27141035 590.00 2.10923360e-01 -5.29278303e-01 5.69758006e-01 -1.19157401 0.29158174 590.25 5.30886279e-02 -6.24517667e-01 6.26770068e-01 -1.48599280 0.26465297 590.50 -1.40940965e-02 -8.06659915e-01 8.06783033e-01 -1.58826672 0.32208197 590.75 -3.58398356e-01 -8.51167593e-01 9.23545154e-01 -1.96933075 0.39393163 591.00 -7.28373912e-01 -7.80028741e-01 1.06722696e+00 -2.32196315 0.54830193 591.25 -1.14163897e+00 -3.97186419e-01 1.20875829e+00 -2.80678190 0.61014022 591.50 -1.21609262e+00 -3.21899133e-01 1.25797469e+00 -2.88282771 0.64942196 591.75 -1.30990596e+00 -4.06827617e-02 1.31053756e+00 -3.11054486 0.69698898 592.00 -1.13045386e+00 1.95533924e-01 1.14723993e+00 2.97031793 0.61528619 592.25 -8.68949813e-01 4.74028882e-01 9.89836935e-01 2.64219604 0.61826763 592.50 -8.27721961e-01 5.21132013e-01 9.78111558e-01 2.57969381 0.65402084 592.75 -8.16440266e-01 5.52859657e-01 9.86016484e-01 2.54636144 0.65731727 593.00 -6.86844809e-01 5.42393371e-01 8.75183615e-01 2.47317098 0.63414584 593.25 -6.23781463e-01 6.28504048e-01 8.85505873e-01 2.35242333 0.56772012 593.50 -8.03767330e-01 7.85805465e-01 1.12406946e+00 2.36749382 0.63715542 593.75 -7.08737337e-01 1.05204972e+00 1.26850985e+00 2.16363370 0.65394074 594.00 -2.67500493e-01 1.52462623e+00 1.54791526e+00 1.74448166 0.64209513 594.25 3.00200080e-01 1.79666012e+00 1.82156737e+00 1.40523788 0.66139111 594.50 7.16958594e-01 1.68641443e+00 1.83249100e+00 1.16880893 0.71406061 594.75 9.43437857e-01 1.62907886e+00 1.88254427e+00 1.04586865 0.75462013 595.00 1.29645329e+00 1.52162946e+00 1.99903661e+00 0.86513279 0.80372749 595.25 1.58059575e+00 1.41829914e+00 2.12364200e+00 0.73133210 0.83165353 595.50 2.14041999e+00 1.32012435e+00 2.51478151e+00 0.55265160 0.85533807 595.75 2.49483827e+00 9.67824364e-01 2.67598617e+00 0.37005871 0.79474438 596.00 2.84601930e+00 -1.28834429e-01 2.84893387e+00 -0.04523741 0.75987742 596.25 3.16186172e+00 -7.70265318e-01 3.25433222e+00 -0.23895681 0.85450963 596.50 3.05898150e+00 -1.35547398e+00 3.34584482e+00 -0.41711182 0.87260775 596.75 2.80284530e+00 -1.83325801e+00 3.34914567e+00 -0.57923131 0.83669931 597.00 2.11750637e+00 -2.70236915e+00 3.43316651e+00 -0.90615176 0.81826411 597.25 1.72033965e+00 -3.23766948e+00 3.66634316e+00 -1.08238343 0.82506802 597.50 1.48135357e-01 -3.60834848e+00 3.61138794e+00 -1.52976586 0.77931063 597.75 -6.16401617e-01 -3.44256957e+00 3.49731843e+00 -1.74797161 0.83141390 598.00 -1.40134292e+00 -2.98081206e+00 3.29378240e+00 -2.01025647 0.79844284 598.25 -1.81521191e+00 -2.78301114e+00 3.32267141e+00 -2.14874985 0.86472293 598.50 -2.08736814e+00 -2.32297434e+00 3.12302986e+00 -2.30282393 0.86177448 598.75 -2.23524389e+00 -1.91221680e+00 2.94157922e+00 -2.43392308 0.85684503 599.00 -2.50105396e+00 -1.45433426e+00 2.89315728e+00 -2.61489572 0.82700017 599.25 -2.71514412e+00 -1.17168255e+00 2.95716884e+00 -2.73419897 0.82888163 599.50 -2.63261837e+00 -3.80586026e-01 2.65998594e+00 -2.99802172 0.74371046 599.75 -2.30671908e+00 1.17645229e-01 2.30971715e+00 3.09063570 0.69361573 600.00 -1.61000259e+00 7.60316576e-01 1.78050264e+00 2.70039409 0.55289006 600.25 -1.36802415e+00 9.53123635e-01 1.66731363e+00 2.53307445 0.58611910 600.50 -1.29938769e+00 5.60174284e-01 1.41499244e+00 2.73456126 0.62608969 600.75 -1.14548109e+00 4.84864351e-01 1.24387313e+00 2.74117598 0.59387215 601.00 -1.16782195e+00 4.33281386e-01 1.24560864e+00 2.78631880 0.61125834 601.25 -1.07596022e+00 3.82550278e-01 1.14194357e+00 2.79998818 0.48674896 601.50 -9.07584911e-01 5.32848082e-01 1.05244356e+00 2.61070837 0.46874590 601.75 -7.69168227e-01 7.42533514e-01 1.06910045e+00 2.37381169 0.48965946 602.00 -3.43136542e-01 8.19068189e-01 8.88040193e-01 1.96751889 0.43260784 602.25 -1.77805573e-01 4.28992507e-01 4.64380655e-01 1.96371636 0.17239941 602.50 -4.98035182e-01 4.21156859e-01 6.52236263e-01 2.43963713 0.24355937 602.75 -5.23582779e-01 3.51929823e-01 6.30867281e-01 2.54979868 0.30668603 603.00 -6.98014750e-01 1.58775058e-01 7.15845032e-01 2.91793169 0.52663166 603.25 -9.04268363e-01 2.17892940e-01 9.30149776e-01 2.90513970 0.65360142 603.50 -1.07920848e+00 3.61630634e-01 1.13818612e+00 2.81826305 0.80490337 603.75 -1.12809154e+00 6.63826696e-01 1.30891421e+00 2.60970828 0.82790104 604.00 -1.18316801e+00 8.72005846e-01 1.46978935e+00 2.50645755 0.87859704 604.25 -1.02732966e+00 1.10750317e+00 1.51061892e+00 2.31865719 0.88838122 604.50 -9.36446416e-01 1.23901543e+00 1.55309083e+00 2.21799837 0.91128909 604.75 -7.72338727e-01 1.39055772e+00 1.59064700e+00 2.07778858 0.87928416 605.00 -6.35633140e-01 1.51465079e+00 1.64261879e+00 1.96813234 0.86257222 605.25 -1.44822007e-01 1.69231044e+00 1.69849582e+00 1.65616484 0.79439572 605.50 3.40785047e-01 1.73126265e+00 1.76448429e+00 1.37643923 0.79930187 605.75 5.19797444e-01 1.34921683e+00 1.44588223e+00 1.20306225 0.72517968 606.00 6.07150720e-01 1.08828063e+00 1.24618888e+00 1.06190883 0.73700775 606.25 6.46685741e-01 7.72104942e-01 1.00714869e+00 0.87356764 0.64406844 606.50 6.66339032e-01 5.25357026e-01 8.48532681e-01 0.66764183 0.61575652 606.75 4.30494302e-01 2.99370787e-01 5.24355043e-01 0.60763995 0.33084536 607.00 2.67989082e-01 2.02564133e-02 2.68753550e-01 0.07544325 0.13236945 607.25 -2.31068245e-02 -1.01100042e-02 2.52217669e-02 -2.72915430 0.00105034 607.50 -4.40971564e-01 -2.50040250e-02 4.41679885e-01 -3.08495118 0.21788388 607.75 -8.05516854e-01 2.35283880e-01 8.39175731e-01 2.85740792 0.60746573 608.00 -8.69025963e-01 4.25920670e-01 9.67788479e-01 2.68588612 0.69739997 608.25 -8.91731715e-01 9.11672552e-01 1.27527734e+00 2.34513761 0.75069054 608.50 -9.21779406e-01 1.14372769e+00 1.46894190e+00 2.24915060 0.81762300 608.75 -6.72793153e-01 1.42830844e+00 1.57883363e+00 2.01101028 0.88863208 609.00 -5.30540699e-01 1.53288326e+00 1.62209880e+00 1.90399825 0.90851004 609.25 -3.63664361e-01 1.65984956e+00 1.69922110e+00 1.78648303 0.92743473 609.50 -1.62224211e-01 1.68272360e+00 1.69052519e+00 1.66690505 0.92801504 609.75 2.01303205e-01 1.65435287e+00 1.66655525e+00 1.44971066 0.95100875 610.00 2.75700627e-01 1.65781824e+00 1.68058685e+00 1.40600123 0.96359459 610.25 2.42493876e-01 1.68254322e+00 1.69992793e+00 1.42765855 0.96876977 610.50 3.33369609e-01 1.67639952e+00 1.70922516e+00 1.37449670 0.96270939 610.75 6.49845611e-01 1.62278106e+00 1.74806112e+00 1.18990052 0.96684910 611.00 7.55280672e-01 1.56841541e+00 1.74079746e+00 1.12201207 0.97121601 611.25 8.97770452e-01 1.45775538e+00 1.71202878e+00 1.01879799 0.97936522 611.50 9.48110354e-01 1.36389582e+00 1.66106142e+00 0.96333372 0.97573413 611.75 1.02574903e+00 1.27425754e+00 1.63581581e+00 0.89302751 0.97588058 612.00 1.09721394e+00 1.22360098e+00 1.64349561e+00 0.83980247 0.97739372 612.25 1.15254616e+00 1.16848955e+00 1.64125881e+00 0.79226714 0.97572898 612.50 1.24557482e+00 1.11642696e+00 1.67268221e+00 0.73077526 0.97174013 612.75 1.30437503e+00 1.04129361e+00 1.66903763e+00 0.67370866 0.97369593 613.00 1.32502428e+00 9.36304525e-01 1.62245354e+00 0.61516310 0.96456840 613.25 1.40349069e+00 7.97833095e-01 1.61441127e+00 0.51690798 0.96702897 613.50 1.41078257e+00 6.43099432e-01 1.55044650e+00 0.42770472 0.95200357 613.75 1.41780132e+00 4.83157549e-01 1.49786575e+00 0.32843702 0.97197718 614.00 1.39592800e+00 3.69771627e-01 1.44407272e+00 0.25894580 0.96650422 614.25 1.39675375e+00 2.49194444e-01 1.41880897e+00 0.17655214 0.97462920 614.50 1.31076026e+00 1.44504870e-01 1.31870168e+00 0.10980167 0.96420210 614.75 1.23070016e+00 -8.14314290e-03 1.23072710e+00 -0.00661658 0.96152371 615.00 1.11700242e+00 -3.90295676e-02 1.11768409e+00 -0.03492714 0.95326869 615.25 1.05103408e+00 -5.65168949e-02 1.05255252e+00 -0.05372092 0.96330451 615.50 1.00495337e+00 -1.20582959e-01 1.01216181e+00 -0.11941770 0.95979733 615.75 9.59425113e-01 -1.73783986e-01 9.75037138e-01 -0.17919060 0.96668101 616.00 8.46338853e-01 -2.12448338e-01 8.72595983e-01 -0.24593883 0.95452087 616.25 7.73189601e-01 -2.10576430e-01 8.01351728e-01 -0.26589875 0.96260627 616.50 6.90377320e-01 -2.14712726e-01 7.22995435e-01 -0.30152484 0.94732918 616.75 6.10592517e-01 -2.10438058e-01 6.45838524e-01 -0.33189686 0.95154947 617.00 5.28842786e-01 -1.60509962e-01 5.52664582e-01 -0.29467540 0.93148177 617.25 4.90061238e-01 -1.19900894e-01 5.04515849e-01 -0.23995133 0.92761275 617.50 4.39320530e-01 -7.77898735e-02 4.46154449e-01 -0.17525210 0.86982627 617.75 4.48027358e-01 -1.81740259e-02 4.48395817e-01 -0.04054232 0.87814304 618.00 4.14549338e-01 3.50917136e-02 4.16031948e-01 0.08444894 0.87487813 618.25 3.76614636e-01 4.02695611e-02 3.78761431e-01 0.10652039 0.88584367 618.50 3.62100164e-01 1.26801231e-01 3.83660111e-01 0.33683761 0.82520954 618.75 3.78730965e-01 1.90020308e-01 4.23727343e-01 0.46502985 0.88955174 619.00 4.00490096e-01 2.54240507e-01 4.74373854e-01 0.56563221 0.85307807 619.25 4.46204554e-01 3.37984956e-01 5.59760961e-01 0.64826250 0.88852433 619.50 5.75801016e-01 3.97504361e-01 6.99683162e-01 0.60422020 0.93676941 619.75 6.30682190e-01 4.11084012e-01 7.52828061e-01 0.57764552 0.94139406 620.00 7.78479193e-01 4.11744651e-01 8.80660838e-01 0.48650645 0.93686641 620.25 8.57632362e-01 3.89617734e-01 9.41984738e-01 0.42641956 0.93146566 620.50 9.86404827e-01 2.64086069e-01 1.02114442e+00 0.26159099 0.93714635 620.75 1.04469875e+00 1.71043348e-01 1.05860819e+00 0.16228520 0.93931782 621.00 1.10938749e+00 -5.39632821e-02 1.11069917e+00 -0.04860410 0.94653949 621.25 1.07660891e+00 -1.80818017e-01 1.09168764e+00 -0.16639847 0.92361658 621.50 9.81645464e-01 -3.98835639e-01 1.05957429e+00 -0.38591954 0.92267124 621.75 8.76730650e-01 -5.18648887e-01 1.01865269e+00 -0.53419904 0.89702881 622.00 6.89529183e-01 -7.27375069e-01 1.00225994e+00 -0.81210208 0.87609456 622.25 5.56206607e-01 -7.44121592e-01 9.29022461e-01 -0.92891807 0.80939186 622.50 2.69791155e-01 -7.78209104e-01 8.23648394e-01 -1.23708039 0.75295740 622.75 1.44307243e-01 -7.74485128e-01 7.87814568e-01 -1.38658209 0.71318454 623.00 -8.57665612e-02 -6.60453865e-01 6.65999407e-01 -1.69993369 0.56421817 623.25 -1.92867881e-01 -4.92943191e-01 5.29330718e-01 -1.94374370 0.41703159 623.50 -1.93936778e-01 -3.06590118e-01 3.62779512e-01 -2.13481389 0.33343936 623.75 -2.88960564e-01 -1.42424466e-01 3.22153590e-01 -2.68365284 0.28540600 624.00 -3.32829769e-01 4.40468184e-02 3.35731704e-01 3.01001686 0.35547966 624.25 -3.10133656e-01 1.07084351e-01 3.28100508e-01 2.80912487 0.31139332 624.50 -1.73987648e-01 1.62727321e-01 2.38226536e-01 2.38962375 0.20969415 624.75 -4.77271332e-02 1.86695527e-01 1.92699505e-01 1.82107759 0.17694902 625.00 3.39772615e-02 2.33675120e-01 2.36132412e-01 1.42640440 0.30527820 625.25 8.13437083e-02 2.34459629e-01 2.48169531e-01 1.23684908 0.37053537 625.50 7.27681055e-02 2.72769697e-01 2.82309236e-01 1.31009290 0.47408337 625.75 1.69778773e-01 2.94834431e-01 3.40223711e-01 1.04832765 0.48404009 626.00 2.54834521e-01 2.99083630e-01 3.92927030e-01 0.86511273 0.65499511 626.25 2.84393793e-01 2.43596930e-01 3.74458667e-01 0.70828324 0.56861708 626.50 3.51756209e-01 1.74972811e-01 3.92871372e-01 0.46158658 0.65650291 626.75 3.73337332e-01 6.91114252e-02 3.79680329e-01 0.18304577 0.48692506 627.00 3.85890329e-01 2.72725305e-03 3.85899966e-01 0.00706731 0.42021420 627.25 2.71921521e-01 -8.85189479e-02 2.85966637e-01 -0.31471231 0.29178021 627.50 2.43616070e-01 -1.40098469e-01 2.81027349e-01 -0.52189360 0.27899755 627.75 2.11019596e-01 -2.32066459e-01 3.13662416e-01 -0.83286311 0.23443117 628.00 2.05822924e-01 -2.51508658e-01 3.24991817e-01 -0.88496414 0.22587672 628.25 -7.57709949e-02 -3.73486655e-01 3.81095166e-01 -1.77095449 0.16620330 628.50 -2.71873647e-01 -4.71661358e-01 5.44407675e-01 -2.09369490 0.26469987 628.75 -6.04137558e-01 -2.23118662e-01 6.44021837e-01 -2.78781305 0.33744167 629.00 -7.36057091e-01 -3.43569091e-02 7.36858492e-01 -3.09494955 0.47271293 629.25 -6.36953753e-01 4.38407957e-01 7.73247451e-01 2.53877006 0.46658759 629.50 -4.67231927e-01 5.99844979e-01 7.60341813e-01 2.23255150 0.36126300 629.75 -3.96330261e-01 3.43101753e-01 5.24210347e-01 2.42805620 0.21131613 630.00 -4.92744960e-01 2.48764820e-01 5.51979647e-01 2.67406849 0.18148093 630.25 -1.10496957e+00 1.23342337e-01 1.11183231e+00 3.03042774 0.30292487 630.50 -1.22297908e+00 3.63638344e-01 1.27589603e+00 2.85257970 0.34080161 630.75 -1.22556701e+00 1.19498236e+00 1.71172350e+00 2.36882924 0.45109765 631.00 -1.04588696e+00 1.52603329e+00 1.85004247e+00 2.17163120 0.55355655 631.25 -4.17664579e-01 1.95464540e+00 1.99877020e+00 1.78130849 0.59379822 631.50 8.96654388e-03 1.83824159e+00 1.83826346e+00 1.56591858 0.52175790 631.75 5.90136043e-01 1.41543903e+00 1.53353454e+00 1.17578263 0.59825210 632.00 3.92344221e-01 1.37875969e+00 1.43349652e+00 1.29356124 0.59601543 632.25 4.73233759e-01 1.18115961e+00 1.27243397e+00 1.18972815 0.52894253 632.50 2.82599810e-01 1.13223582e+00 1.16697069e+00 1.32619937 0.50209881 632.75 2.38340939e-01 1.05275720e+00 1.07939989e+00 1.34815272 0.50860723 633.00 2.26721749e-01 1.17800370e+00 1.19962305e+00 1.38065858 0.61647048 633.25 2.56233523e-01 9.85743394e-01 1.01850167e+00 1.31648505 0.58006772 633.50 3.30696928e-01 9.48145959e-01 1.00416195e+00 1.23520635 0.56146474 633.75 4.53831696e-01 9.93207716e-01 1.09198204e+00 1.14218997 0.63029989 634.00 5.53926406e-01 9.33358885e-01 1.08535398e+00 1.03518745 0.66934472 634.25 4.94021609e-01 7.36157917e-01 8.86558418e-01 0.97974385 0.67088867 634.50 3.20552537e-01 5.41609471e-01 6.29360586e-01 1.03638970 0.38676278 634.75 4.94424156e-02 2.93540688e-01 2.97675474e-01 1.40392797 0.15017646 635.00 5.87310523e-02 1.82642806e-01 1.91853410e-01 1.25967679 0.04144315 635.25 8.31069070e-02 4.57119109e-01 4.64612353e-01 1.39095481 0.17840426 635.50 -4.77671595e-02 5.71092682e-01 5.73086863e-01 1.65424379 0.18513838 635.75 -4.09385532e-01 6.82918017e-01 7.96224549e-01 2.11082244 0.40417421 636.00 -5.52951096e-01 8.91857638e-01 1.04936407e+00 2.12579154 0.50984824 636.25 -5.43427031e-01 1.01499278e+00 1.15131372e+00 2.06236119 0.55338822 636.50 -4.36536319e-01 1.18647489e+00 1.26423361e+00 1.92335177 0.54051343 636.75 -3.97391679e-01 1.29823505e+00 1.35769451e+00 1.86784137 0.53802364 637.00 -4.79449418e-01 1.65462922e+00 1.72269255e+00 1.85283461 0.59723026 637.25 -6.43347661e-01 1.99311957e+00 2.09437862e+00 1.88302288 0.76727081 637.50 -3.03704316e-01 1.88993499e+00 1.91418143e+00 1.73012979 0.67795508 637.75 -7.39118164e-02 1.90761914e+00 1.90905048e+00 1.60952254 0.67620010 638.00 -5.61979051e-02 2.05205459e+00 2.05282397e+00 1.59817565 0.60438984 638.25 1.28014411e-01 2.12458218e+00 2.12843537e+00 1.51061516 0.55107112 638.50 9.99561627e-01 1.76478987e+00 2.02820283e+00 1.05545578 0.47918780 638.75 1.65800985e+00 1.97725499e+00 2.58041352e+00 0.87299239 0.63025721 639.00 1.79655509e+00 1.81923708e+00 2.55680147e+00 0.79167112 0.68978577 639.25 1.91305236e+00 1.50278269e+00 2.43271970e+00 0.66586261 0.70403450 639.50 1.92785639e+00 1.23454828e+00 2.28926619e+00 0.56957816 0.84154689 639.75 1.89297490e+00 1.06670436e+00 2.17283505e+00 0.51315399 0.83660237 640.00 1.80124202e+00 8.71785374e-01 2.00112033e+00 0.45075878 0.85161169 640.25 1.73915205e+00 8.96944851e-01 1.95682394e+00 0.47615771 0.87169411 640.50 1.67416616e+00 9.48517713e-01 1.92419286e+00 0.51546923 0.86519556 640.75 1.66577010e+00 9.97589526e-01 1.94164231e+00 0.53959253 0.88322095 641.00 1.57840227e+00 1.02924248e+00 1.88432848e+00 0.57783513 0.92366673 641.25 1.55050766e+00 1.08040654e+00 1.88980219e+00 0.60858064 0.91680706 641.50 1.69623460e+00 1.04248696e+00 1.99097737e+00 0.55107763 0.89266299 641.75 1.74701257e+00 1.01222891e+00 2.01907412e+00 0.52513892 0.88500697 642.00 1.81341311e+00 9.58019283e-01 2.05091883e+00 0.48602749 0.90735261 642.25 1.82904481e+00 9.74754808e-01 2.07257131e+00 0.48964409 0.91155010 642.50 1.82055306e+00 8.94629757e-01 2.02849103e+00 0.45674839 0.91564422 642.75 1.73426378e+00 8.50448948e-01 1.93156265e+00 0.45592235 0.90482380 643.00 1.64234911e+00 7.36603481e-01 1.79997091e+00 0.42161085 0.91456495 643.25 1.60901384e+00 7.60286429e-01 1.77959574e+00 0.44142050 0.91220455 643.50 1.58045266e+00 8.46517957e-01 1.79288127e+00 0.49173390 0.90403125 643.75 1.59860993e+00 8.29365408e-01 1.80094439e+00 0.47857749 0.89573519 644.00 1.53606919e+00 8.45239067e-01 1.75326485e+00 0.50304362 0.84510260 644.25 1.52231212e+00 8.77351215e-01 1.75703709e+00 0.52283179 0.85256197 644.50 1.51154840e+00 9.53671300e-01 1.78725139e+00 0.56284752 0.87432027 644.75 1.55364864e+00 9.15080213e-01 1.80310728e+00 0.53228300 0.85704086 645.00 1.57390388e+00 8.57726586e-01 1.79244758e+00 0.49897134 0.89758073 645.25 1.53951210e+00 8.97710308e-01 1.78212831e+00 0.52791042 0.84982909 645.50 1.64916081e+00 1.09588130e+00 1.98007252e+00 0.58650697 0.86596772 645.75 1.62542683e+00 1.08255542e+00 1.95293078e+00 0.58754994 0.87470016 646.00 1.68711498e+00 1.03587696e+00 1.97974696e+00 0.55064506 0.90301013 646.25 1.77195563e+00 1.13507023e+00 2.10433153e+00 0.56972090 0.90487031 646.50 1.78764904e+00 1.31218563e+00 2.21754825e+00 0.63320085 0.91772537 646.75 2.04875293e+00 1.49489916e+00 2.53616090e+00 0.63035786 0.91788866 647.00 2.34762694e+00 1.62617309e+00 2.85583459e+00 0.60580173 0.93071861 647.25 2.52002508e+00 1.63281571e+00 3.00276765e+00 0.57492309 0.91704892 647.50 2.93186173e+00 1.57165932e+00 3.32654870e+00 0.49207922 0.90643078 647.75 3.35141152e+00 1.29255612e+00 3.59202735e+00 0.36809670 0.88196697 648.00 3.59472379e+00 8.77739222e-01 3.70033313e+00 0.23948820 0.88376979 648.25 3.83443087e+00 -1.60232064e-02 3.83446435e+00 -0.00417875 0.91203795 648.50 3.91093951e+00 -4.65856047e-01 3.93858727e+00 -0.11855753 0.93305679 648.75 3.23699720e+00 -8.89141653e-01 3.35689198e+00 -0.26806962 0.91481641 649.00 2.76454101e+00 -9.85987590e-01 2.93510792e+00 -0.34259127 0.90242228 649.25 2.46656944e+00 -7.40726390e-01 2.57539130e+00 -0.29173780 0.91312944 649.50 2.29509408e+00 -6.47507379e-01 2.38468502e+00 -0.27497972 0.93459122 649.75 2.19052190e+00 -3.85776192e-01 2.22423233e+00 -0.17432398 0.89323418 650.00 2.29160608e+00 -3.12612505e-01 2.31283052e+00 -0.13557945 0.91491400 650.25 2.33436749e+00 -3.30299037e-01 2.35761935e+00 -0.14056094 0.95221513 650.50 2.39345749e+00 -3.90879870e-01 2.42516511e+00 -0.16188273 0.95310197 650.75 2.32144158e+00 -4.54919650e-01 2.36559567e+00 -0.19351208 0.95023752 651.00 2.18027059e+00 -5.25403074e-01 2.24268326e+00 -0.23647204 0.94602571 651.25 1.95907252e+00 -6.60213699e-01 2.06732854e+00 -0.32504979 0.93575506 651.50 1.75669576e+00 -6.91319265e-01 1.88783005e+00 -0.37491972 0.91120210 651.75 1.64989741e+00 -6.23362585e-01 1.76372967e+00 -0.36123983 0.88475383 652.00 1.56504652e+00 -5.82376495e-01 1.66989011e+00 -0.35623852 0.85221011 652.25 1.35545117e+00 -2.09524609e-01 1.37154965e+00 -0.15336538 0.79560404 652.50 1.31879657e+00 -3.24428069e-01 1.35811559e+00 -0.24121337 0.80537215 652.75 1.03562926e+00 -4.46278574e-01 1.12769346e+00 -0.40687848 0.77647661 653.00 7.69992745e-01 -2.87707582e-01 8.21988126e-01 -0.35758635 0.57690315 653.25 4.34719975e-01 2.06879079e-01 4.81435779e-01 0.44417460 0.31473740 653.50 3.18822558e-01 5.40569698e-01 6.27585390e-01 1.03791807 0.32840767 653.75 1.53975197e-01 1.10131072e+00 1.11202233e+00 1.43188590 0.64075719 654.00 2.03093948e-01 1.31352388e+00 1.32913210e+00 1.41739345 0.70679997 654.25 2.65555040e-01 1.59141481e+00 1.61341891e+00 1.40545248 0.76380369 654.50 4.47461431e-01 1.75899921e+00 1.81502065e+00 1.32169573 0.77424065 654.75 9.43407257e-01 1.77323136e+00 2.00857330e+00 1.08185646 0.70686940 655.00 1.20350515e+00 1.47794162e+00 1.90597379e+00 0.88738946 0.73702136 655.25 1.26537189e+00 1.10947754e+00 1.68288634e+00 0.71984832 0.78032423 655.50 1.06141747e+00 9.25693042e-01 1.40837305e+00 0.71720168 0.69725958 655.75 8.82326057e-01 7.90406292e-01 1.18458490e+00 0.73050151 0.57327206 656.00 6.20778512e-01 6.59096989e-01 9.05414160e-01 0.81532844 0.38191882 656.25 4.84054651e-01 5.16433527e-01 7.07822360e-01 0.81774995 0.25901448 656.50 3.46767832e-01 4.16742618e-01 5.42146049e-01 0.87679161 0.11415499 656.75 -8.95608979e-03 5.39483352e-01 5.39557688e-01 1.58739604 0.09185307 657.00 -7.46607949e-01 5.43588940e-01 9.23532547e-01 2.51226977 0.10894263 657.25 -9.29552280e-01 7.59190773e-01 1.20018252e+00 2.45673500 0.11313488 657.50 -8.39123213e-01 1.28266300e+00 1.53275964e+00 2.15012121 0.16241098 657.75 -5.58459937e-01 1.31725062e+00 1.43074341e+00 1.97178470 0.15833448 658.00 5.21586415e-01 1.19396455e+00 1.30292123e+00 1.15892948 0.19508684 658.25 8.22657821e-01 8.53036204e-01 1.18508930e+00 0.80352501 0.18881958 658.50 1.14868224e+00 4.06869133e-01 1.21861125e+00 0.34041611 0.27860604 658.75 9.98687775e-01 2.24670987e-01 1.02364756e+00 0.22128226 0.25682302 659.00 7.41389692e-01 2.46122073e-01 7.81175236e-01 0.32052662 0.27899867 659.25 5.81451025e-01 3.03639648e-01 6.55959092e-01 0.48125747 0.26638510 659.50 5.20348434e-01 1.59242671e-01 5.44169754e-01 0.29698045 0.20467709 659.75 5.87079622e-01 1.61873058e-01 6.08987167e-01 0.26904095 0.21149244 660.00 8.24032223e-01 1.99214615e-01 8.47770941e-01 0.23720454 0.31037108 660.25 7.42856410e-01 1.17155265e-01 7.52037899e-01 0.15642081 0.31431969 660.50 6.56878587e-01 1.35424689e-01 6.70693167e-01 0.20331536 0.25110234 660.75 6.09076829e-01 3.34826249e-01 6.95041869e-01 0.50263393 0.26072251 661.00 4.06501041e-01 7.24514622e-01 8.30761418e-01 1.05949632 0.30768693 661.25 4.04346209e-01 8.20249559e-01 9.14497237e-01 1.11280050 0.36172352 661.50 5.74469075e-01 1.10396770e+00 1.24449162e+00 1.09098768 0.46303479 661.75 4.76010445e-01 9.95048706e-01 1.10304482e+00 1.12459461 0.36844050 662.00 2.40713788e-01 7.28770802e-01 7.67495934e-01 1.25177727 0.18422770 662.25 4.04799119e-01 6.52656752e-01 7.67999454e-01 1.01563246 0.25337960 662.50 4.74116399e-01 6.27348845e-01 7.86354203e-01 0.92362789 0.22211867 662.75 2.92401347e-01 6.98844183e-01 7.57549826e-01 1.17452318 0.20982343 663.00 6.13475179e-01 7.41516110e-01 9.62391779e-01 0.87961416 0.46291768 663.25 6.13163471e-01 6.41015922e-01 8.87057413e-01 0.80760222 0.49433996 663.50 3.90516910e-01 4.95461880e-01 6.30861262e-01 0.90329968 0.39388287 663.75 2.83671507e-01 4.69418109e-01 5.48473231e-01 1.02721771 0.42009738 664.00 2.30411128e-02 3.72540471e-01 3.73252321e-01 1.50902639 0.42296570 664.25 -1.45868878e-01 3.16351750e-01 3.48362110e-01 2.00284020 0.35514492 664.50 -4.74457309e-01 1.51667284e-01 4.98109128e-01 2.83219383 0.41232553 664.75 -6.74822558e-01 4.07340646e-02 6.76050848e-01 3.08130318 0.55533258 665.00 -7.06468853e-01 -2.50772502e-01 7.49656646e-01 -2.80050055 0.59745561 665.25 -6.66173490e-01 -4.64253555e-01 8.11984287e-01 -2.53295304 0.55005993 665.50 -6.41886646e-01 -6.79295866e-01 9.34591536e-01 -2.32788710 0.55417295 665.75 -3.79099081e-01 -8.24525059e-01 9.07500791e-01 -2.00175242 0.48059611 666.00 -6.14038934e-01 -6.97912172e-01 9.29583354e-01 -2.29235122 0.36435930 666.25 -7.79694139e-01 -2.90515357e-01 8.32058966e-01 -2.78492626 0.38599715 666.50 -7.50000157e-01 -1.74089071e-01 7.69939764e-01 -2.91351294 0.49688172 666.75 -8.44083450e-01 -3.38430524e-01 9.09402051e-01 -2.76027241 0.63771244 667.00 -8.66288854e-01 -4.03136738e-01 9.55497571e-01 -2.70603849 0.77380592 667.25 -7.88437603e-01 -4.27477377e-01 8.96867193e-01 -2.64477087 0.73653415 667.50 -7.52670599e-01 -4.64967454e-01 8.84707728e-01 -2.58821882 0.71549339 667.75 -7.31149475e-01 -5.00328099e-01 8.85950202e-01 -2.54147916 0.76669846 668.00 -6.99381041e-01 -5.36096856e-01 8.81211484e-01 -2.48759573 0.82741356 668.25 -5.93418766e-01 -5.43891265e-01 8.04961825e-01 -2.39971493 0.87179610 668.50 -5.55680898e-01 -5.82600942e-01 8.05111867e-01 -2.33254918 0.87574976 668.75 -4.20108432e-01 -5.80825733e-01 7.16833053e-01 -2.19698613 0.82383079 669.00 -3.32849567e-01 -5.73398680e-01 6.63004435e-01 -2.09674326 0.74058961 669.25 -2.62231248e-01 -7.44425955e-01 7.89262459e-01 -1.90948280 0.75787521 669.50 -1.93954443e-01 -7.75367753e-01 7.99258080e-01 -1.81591155 0.71425882 669.75 -1.27989439e-01 -8.18796409e-01 8.28739317e-01 -1.72585566 0.61487204 670.00 -2.69643558e-01 -9.14293403e-01 9.53226140e-01 -1.85758623 0.56815887 670.25 -5.98356440e-01 -9.37937291e-01 1.11254519e+00 -2.13865335 0.48862822 670.50 -7.61212070e-01 -9.98930333e-01 1.25590829e+00 -2.22195050 0.51685143 670.75 -8.94423652e-01 -7.28151876e-01 1.15334246e+00 -2.45831202 0.62309253 671.00 -9.85780071e-01 -5.85876685e-01 1.14674053e+00 -2.60535419 0.77149323 671.25 -1.04447587e+00 -5.65166670e-01 1.18757871e+00 -2.64560755 0.90763301 671.50 -9.92605014e-01 -5.27262267e-01 1.12395294e+00 -2.65330518 0.91174574 671.75 -8.08251891e-01 -4.54991444e-01 9.27517295e-01 -2.62887453 0.83207427 672.00 -7.61991485e-01 -3.75701874e-01 8.49578084e-01 -2.68351840 0.79430447 672.25 -5.58262278e-01 -2.35608398e-01 6.05943965e-01 -2.74223276 0.76741179 672.50 -4.74415585e-01 -1.88615763e-01 5.10535066e-01 -2.76317856 0.76866857 672.75 -3.45400971e-01 -1.06996908e-01 3.61593928e-01 -2.84119142 0.56746212 673.00 -2.44531572e-01 -1.29029256e-01 2.76485512e-01 -2.65606356 0.40996618 673.25 -5.08911015e-02 -1.95106802e-01 2.01634740e-01 -1.82594836 0.28150893 673.50 5.84918590e-03 -2.21374757e-01 2.21452017e-01 -1.54438037 0.30219532 673.75 -8.16215394e-03 -2.60859734e-01 2.60987397e-01 -1.60207556 0.37576227 674.00 1.23876235e-02 -2.72451750e-01 2.72733220e-01 -1.52536040 0.36685971 674.25 7.22127804e-02 -2.02881845e-01 2.15350246e-01 -1.22884388 0.26989745 674.50 1.69061692e-01 -1.83777820e-01 2.49712120e-01 -0.82708172 0.30361232 674.75 2.73887980e-01 -7.61697694e-02 2.84282359e-01 -0.27125112 0.33412702 675.00 4.08278214e-01 4.58308885e-02 4.10842513e-01 0.11178609 0.36900867 675.25 5.32267063e-01 2.95973559e-01 6.09022639e-01 0.50748552 0.59362452 675.50 5.71454196e-01 3.94313118e-01 6.94292974e-01 0.60399450 0.71364387 675.75 6.38764130e-01 5.98749649e-01 8.75511710e-01 0.75307485 0.76986850 676.00 5.86969370e-01 8.51396759e-01 1.03412257e+00 0.96720685 0.77238083 676.25 5.30548329e-01 1.07109628e+00 1.19529443e+00 1.11089004 0.84056295 676.50 4.20948255e-01 1.08781458e+00 1.16642102e+00 1.20157561 0.83447644 676.75 4.08248892e-01 1.15211580e+00 1.22230846e+00 1.23025407 0.85765135 677.00 2.80910668e-01 1.19632439e+00 1.22886242e+00 1.34016305 0.86000704 677.25 2.11668883e-01 1.20573643e+00 1.22417485e+00 1.39701556 0.89546937 677.50 1.90542726e-01 1.13224069e+00 1.14816180e+00 1.40407038 0.89419207 677.75 2.10162639e-01 1.07313587e+00 1.09352134e+00 1.37740421 0.91894606 678.00 1.30659650e-01 1.02451648e+00 1.03281459e+00 1.44394809 0.94708209 678.25 8.68636295e-02 9.97422709e-01 1.00119796e+00 1.48392742 0.95536352 678.50 8.04426710e-02 8.94964136e-01 8.98572105e-01 1.48115354 0.95928926 678.75 3.25614028e-02 8.44485147e-01 8.45112660e-01 1.53225772 0.96016265 679.00 -1.85139924e-02 7.97011635e-01 7.97226639e-01 1.59402141 0.96735864 679.25 -2.73365496e-02 7.81785098e-01 7.82262888e-01 1.60574892 0.97456546 679.50 1.17867849e-02 7.66421179e-01 7.66511808e-01 1.55541855 0.97074662 679.75 5.41005285e-02 7.33210481e-01 7.35203698e-01 1.49714399 0.96410679 680.00 1.01834207e-01 6.55089470e-01 6.62957329e-01 1.41657980 0.94857274 680.25 1.08721208e-01 5.88199352e-01 5.98162837e-01 1.38802183 0.94908961 680.50 1.00322610e-01 5.07950906e-01 5.17763217e-01 1.37580139 0.96347311 680.75 9.23102273e-02 4.83702041e-01 4.92431562e-01 1.38222272 0.96156833 681.00 8.43264854e-02 4.23003011e-01 4.31326446e-01 1.37402395 0.95192098 681.25 7.46415077e-02 4.04471133e-01 4.11300683e-01 1.38830841 0.95286789 681.50 3.74863497e-02 3.97479218e-01 3.99242978e-01 1.47676424 0.93070695 681.75 3.14146260e-02 3.81560797e-01 3.82851826e-01 1.48864970 0.92711217 682.00 7.05952336e-02 3.24384115e-01 3.31977019e-01 1.35650915 0.88353845 682.25 8.53786916e-02 2.82795312e-01 2.95402623e-01 1.27758829 0.81094475 682.50 3.55399843e-02 1.93292802e-01 1.96532943e-01 1.38896121 0.70174378 682.75 5.08401617e-03 1.81867370e-01 1.81938416e-01 1.54284908 0.67608877 683.00 -6.24462019e-02 1.30927864e-01 1.45057346e-01 2.01583546 0.50759947 683.25 -1.28049267e-01 1.00773042e-01 1.62947295e-01 2.47483731 0.51382982 683.50 -2.17623840e-01 1.26911421e-01 2.51925871e-01 2.61364102 0.75227729 683.75 -2.42649852e-01 1.55682960e-01 2.88298691e-01 2.57114867 0.79334481 684.00 -2.86547592e-01 2.04766582e-01 3.52191533e-01 2.52113585 0.82266642 684.25 -2.99330638e-01 2.47858630e-01 3.88629298e-01 2.44998469 0.85297518 684.50 -3.40498154e-01 3.09966325e-01 4.60454249e-01 2.40309857 0.86717083 684.75 -3.89860580e-01 3.36475333e-01 5.14982447e-01 2.42956196 0.87344077 685.00 -4.28949303e-01 4.04787711e-01 5.89788602e-01 2.38516625 0.90049468 685.25 -3.92557260e-01 4.23792712e-01 5.77668993e-01 2.31795082 0.87078892 685.50 -3.75220015e-01 4.71326272e-01 6.02443785e-01 2.24315102 0.82671538 685.75 -3.87101703e-01 5.15216878e-01 6.44434760e-01 2.21515281 0.79385929 686.00 -4.13961171e-01 6.00585678e-01 7.29429234e-01 2.17427949 0.73653940 686.25 -3.94660278e-01 7.46523995e-01 8.44425729e-01 2.05711123 0.71110163 686.50 -1.85522049e-01 8.19304303e-01 8.40046411e-01 1.79347954 0.68231941 686.75 -1.01487147e-02 7.52159564e-01 7.52228028e-01 1.58428828 0.64615113 687.00 8.63805593e-02 6.21623408e-01 6.27596417e-01 1.43272090 0.61711862 687.25 1.11172173e-01 6.34224634e-01 6.43894509e-01 1.39727092 0.70869055 687.50 1.12017583e-01 7.04940138e-01 7.13784658e-01 1.41321020 0.75966419 687.75 1.43510190e-01 7.76260079e-01 7.89414267e-01 1.38798654 0.72177749 688.00 8.04737532e-02 9.07662999e-01 9.11223432e-01 1.48236716 0.70594980 688.25 1.95941105e-01 9.90380097e-01 1.00957697e+00 1.37547437 0.55314008 688.50 5.71283499e-01 9.83455279e-01 1.13734301e+00 1.04454366 0.45692175 688.75 7.73429806e-01 2.37314923e-01 8.09019182e-01 0.29771509 0.53867007 689.00 7.62457483e-01 1.50537677e-01 7.77176303e-01 0.19493038 0.74033853 689.25 5.57189749e-01 1.35604358e-01 5.73453536e-01 0.23873084 0.72827373 689.50 4.20903771e-01 1.43368629e-01 4.44651041e-01 0.32829498 0.77045775 689.75 3.49420067e-01 1.08293737e-01 3.65816780e-01 0.30053652 0.76531534 690.00 2.47619232e-01 1.19437631e-01 2.74919319e-01 0.44942324 0.58211965 690.25 -3.72378639e-03 3.19725452e-01 3.19747136e-01 1.58244263 0.35882462 690.50 -5.36909629e-02 5.50208782e-01 5.52822235e-01 1.66807123 0.51450771 690.75 4.48325486e-01 4.85763390e-01 6.61030871e-01 0.82545632 0.46542247 691.00 6.10515837e-01 2.90562675e-01 6.76133312e-01 0.44420669 0.52752364 691.25 6.50756876e-01 2.23778535e-01 6.88157936e-01 0.33120720 0.71899354 691.50 6.28389669e-01 2.23387388e-01 6.66914913e-01 0.34155891 0.78274921 691.75 5.82266252e-01 2.00729410e-01 6.15894702e-01 0.33197956 0.72172328 692.00 6.61750488e-01 2.03807012e-01 6.92424007e-01 0.29876324 0.83679387 692.25 6.15914624e-01 1.57672044e-01 6.35776138e-01 0.25061450 0.88075764 692.50 6.18308743e-01 1.33436167e-01 6.32543210e-01 0.21254863 0.86813773 692.75 7.10691765e-01 8.67555608e-02 7.15967396e-01 0.12147100 0.83976357 693.00 7.42846659e-01 3.42226743e-02 7.43634555e-01 0.04603708 0.84562616 693.25 7.57049334e-01 -2.64732291e-02 7.57512063e-01 -0.03495472 0.86048902 693.50 7.10863786e-01 -3.15398848e-02 7.11563129e-01 -0.04433931 0.85261548 693.75 6.85583682e-01 -3.86752087e-02 6.86673690e-01 -0.05635236 0.82677890 694.00 7.04258181e-01 -8.02649795e-02 7.08817362e-01 -0.11348130 0.79451900 694.25 6.73765662e-01 -3.28064895e-01 7.49390914e-01 -0.45312287 0.78238457 694.50 6.36142637e-01 -4.30940612e-01 7.68366622e-01 -0.59541556 0.77329105 694.75 4.89866189e-01 -5.10869126e-01 7.07782557e-01 -0.80638259 0.73602983 695.00 3.15885652e-01 -5.12916598e-01 6.02384579e-01 -1.01879543 0.68705877 695.25 1.43324877e-01 -4.47041749e-01 4.69455371e-01 -1.26054253 0.75180716 695.50 9.47548505e-02 -3.81485640e-01 3.93077314e-01 -1.32733938 0.75113815 695.75 6.07565229e-02 -3.06074089e-01 3.12045995e-01 -1.37484092 0.75539976 696.00 7.55530325e-02 -2.44210758e-01 2.55630896e-01 -1.27075973 0.73448589 696.25 6.41661134e-02 -2.06145060e-01 2.15900616e-01 -1.26903534 0.79248460 696.50 6.90540851e-02 -1.94273049e-01 2.06180708e-01 -1.22927578 0.79448211 696.75 7.99022042e-02 -1.67792208e-01 1.85845600e-01 -1.12637152 0.80334961 697.00 7.70042027e-02 -1.42494264e-01 1.61969943e-01 -1.07535178 0.74435468 697.25 6.81782180e-02 -1.31171457e-01 1.47831731e-01 -1.09146272 0.70915390 697.50 6.44800721e-02 -1.15058925e-01 1.31894791e-01 -1.05999660 0.69466512 697.75 5.79221594e-02 -1.08123349e-01 1.22660651e-01 -1.07899479 0.75745616 698.00 6.38786616e-02 -9.52160194e-02 1.14658509e-01 -0.97988147 0.73241386 698.25 7.15418213e-02 -8.74347815e-02 1.12973772e-01 -0.88503754 0.74448419 698.50 7.41846079e-02 -5.88403093e-02 9.46865251e-02 -0.67055665 0.67054915 698.75 8.40301584e-02 -5.50590380e-02 1.00461760e-01 -0.58004271 0.80623367 699.00 8.26167781e-02 -6.19157283e-02 1.03242866e-01 -0.64313804 0.80734665 699.25 7.83024118e-02 -6.96666105e-02 1.04807940e-01 -0.72710207 0.87056600 699.50 7.66333369e-02 -5.79773530e-02 9.60939217e-02 -0.64768328 0.82050033 699.75 6.66252945e-02 -4.58496345e-02 8.08771838e-02 -0.60274324 0.80595028 700.00 6.88668870e-02 -4.49906027e-02 8.22605766e-02 -0.57869021 0.75470085 700.25 6.76324810e-02 -3.93122644e-02 7.82279146e-02 -0.52652841 0.79350600 700.50 6.80589375e-02 -2.50849815e-02 7.25346488e-02 -0.35312798 0.80170261 700.75 7.08514311e-02 -1.88364452e-02 7.33125975e-02 -0.25984760 0.84447542 701.00 7.13011207e-02 -1.03164456e-02 7.20435900e-02 -0.14369123 0.79546553 701.25 7.97969099e-02 -8.48650072e-03 8.02469160e-02 -0.10595298 0.79982860 701.50 8.41338874e-02 -9.54017504e-03 8.46730532e-02 -0.11291049 0.84765707 701.75 8.45486889e-02 -1.15772792e-02 8.53376481e-02 -0.13608401 0.86471461 702.00 8.65333864e-02 -1.90520672e-02 8.86059153e-02 -0.21671258 0.71566510 702.25 8.94478561e-02 -2.75607010e-02 9.35976025e-02 -0.29888987 0.72220922 702.50 8.45241736e-02 -2.86353971e-02 8.92430496e-02 -0.32664768 0.58642257 702.75 5.68487419e-02 -2.75289199e-02 6.31634459e-02 -0.45096722 0.33203868 703.00 3.76617589e-02 -2.58352751e-02 4.56713206e-02 -0.60125558 0.29228723 703.25 2.82465014e-02 -1.22777718e-02 3.07994890e-02 -0.41002861 0.14585217 703.50 3.31519238e-02 2.65101271e-02 4.24480493e-02 0.67453101 0.23206123 703.75 5.66794558e-02 4.39667584e-02 7.17330925e-02 0.65975281 0.47926093 704.00 1.16179655e-01 5.42508762e-02 1.28221955e-01 0.43686536 0.73780782 704.25 1.26812413e-01 3.91810286e-02 1.32727318e-01 0.29966424 0.79925895 704.50 1.33315554e-01 1.21273621e-02 1.33866015e-01 0.09071766 0.78914084 704.75 1.27063615e-01 -1.17971811e-02 1.27610093e-01 -0.09257928 0.78443105 705.00 1.12987813e-01 -3.56475105e-02 1.18477808e-01 -0.30561446 0.85194458 705.25 1.02024079e-01 -4.17454758e-02 1.10234284e-01 -0.38838885 0.80096431 705.50 8.11725759e-02 -4.59928729e-02 9.32970065e-02 -0.51550313 0.77771401 705.75 6.74352982e-02 -4.71723196e-02 8.22967021e-02 -0.61040354 0.75105027 706.00 4.60884127e-02 -4.09942158e-02 6.16819870e-02 -0.72696633 0.73382778 706.25 3.64783317e-02 -3.87883649e-02 5.32466519e-02 -0.81607984 0.59203217 706.50 1.63990336e-02 -3.25150506e-02 3.64164361e-02 -1.10367311 0.43613570 706.75 8.08346642e-03 -2.33853565e-02 2.47430258e-02 -1.23798988 0.23965438 707.00 -3.53887857e-03 -1.13424461e-02 1.18816979e-02 -1.87322846 0.06288905 707.25 -6.97412604e-03 6.48570201e-03 9.52379990e-03 2.39246611 0.03929001 707.50 4.14764690e-03 2.65838365e-02 2.69054518e-02 1.41602276 0.35381815 707.75 1.56760949e-02 3.27797181e-02 3.63352428e-02 1.12471962 0.46454880 708.00 2.30390188e-02 3.80474550e-02 4.44792673e-02 1.02631781 0.66242987 708.25 3.13643566e-02 3.89746812e-02 5.00274788e-02 0.89317381 0.65871098 708.50 4.51316700e-02 3.83611091e-02 5.92321055e-02 0.70448364 0.79842939 708.75 5.30480778e-02 3.07470727e-02 6.13146070e-02 0.52529017 0.77571924 709.00 5.54290641e-02 2.34156490e-02 6.01720348e-02 0.39970330 0.80964450 709.25 5.19362998e-02 2.19691353e-02 5.63916851e-02 0.40017673 0.77322230 709.50 4.80770762e-02 1.54709770e-02 5.05050135e-02 0.31133063 0.75890124 709.75 4.28857415e-02 8.97215349e-03 4.38142256e-02 0.20623606 0.64576564 710.00 4.55355294e-02 6.06884629e-04 4.55395734e-02 0.01332693 0.67673246 710.25 5.08140101e-02 -9.79037471e-03 5.17485755e-02 -0.19033840 0.71841711 710.50 4.98608665e-02 -1.14261131e-02 5.11533192e-02 -0.22527039 0.73399649 710.75 4.29332858e-02 -1.20019409e-02 4.45792958e-02 -0.27259009 0.66764063 711.00 4.12783100e-02 -2.31137675e-02 4.73090385e-02 -0.51044985 0.74187468 711.25 4.30478880e-02 -3.57336730e-02 5.59465463e-02 -0.69282183 0.76682408 711.50 4.27601169e-02 -4.15548027e-02 5.96257430e-02 -0.77110375 0.77519132 711.75 3.61419121e-02 -5.70322298e-02 6.75197234e-02 -1.00595792 0.76332437 712.00 3.01997033e-02 -6.55864186e-02 7.22052656e-02 -1.13928074 0.85113923 712.25 2.64166158e-02 -7.80589561e-02 8.24077558e-02 -1.24447588 0.87813724 712.50 1.96545514e-02 -8.49679116e-02 8.72115095e-02 -1.34347714 0.89090264 712.75 1.17417651e-02 -9.30098139e-02 9.37480375e-02 -1.44521841 0.87510454 713.00 8.37835439e-03 -9.97455750e-02 1.00096836e-01 -1.48699579 0.87841517 713.25 -1.54180709e-03 -1.10002592e-01 1.10013397e-01 -1.58481151 0.90081274 713.50 -6.08601455e-03 -1.16753467e-01 1.16911983e-01 -1.62287625 0.91154030 713.75 -1.52437598e-02 -1.24227308e-01 1.25159083e-01 -1.69289455 0.92474571 714.00 -1.83349663e-02 -1.27399181e-01 1.28711780e-01 -1.71373234 0.92916824 714.25 -3.34270152e-02 -1.52484058e-01 1.56104943e-01 -1.78659914 0.92852167 714.50 -3.38675230e-02 -1.56369078e-01 1.59994680e-01 -1.78408896 0.93025476 714.75 -4.86560470e-02 -1.70781804e-01 1.77577689e-01 -1.84834468 0.93885417 715.00 -5.94914071e-02 -1.75249260e-01 1.85071691e-01 -1.89805733 0.92748485 715.25 -7.27665510e-02 -1.73100192e-01 1.87772861e-01 -1.96874087 0.94589013 715.50 -6.84406198e-02 -1.70341027e-01 1.83576098e-01 -1.95284131 0.92436704 715.75 -6.66856297e-02 -1.86170703e-01 1.97753645e-01 -1.91475410 0.93146925 716.00 -5.86132731e-02 -1.94930101e-01 2.03551615e-01 -1.86288481 0.93857587 716.25 -2.83680559e-02 -1.97580267e-01 1.99606384e-01 -1.71339914 0.92915571 716.50 -1.04173144e-02 -2.14681823e-01 2.14934421e-01 -1.61928273 0.92299751 716.75 1.71763976e-02 -2.32887232e-01 2.33519788e-01 -1.49717548 0.93284169 717.00 4.72747950e-02 -2.58748521e-01 2.63031753e-01 -1.39008397 0.88742388 717.25 1.03622250e-01 -2.80290228e-01 2.98831361e-01 -1.21668360 0.87226149 717.50 1.26175155e-01 -2.88873267e-01 3.15226798e-01 -1.15898721 0.78836937 717.75 1.66356941e-01 -3.21906270e-01 3.62351044e-01 -1.09380957 0.61506877 718.00 1.76897892e-01 -3.18318528e-01 3.64169672e-01 -1.06356756 0.42580788 718.25 1.78764997e-01 -3.33703527e-01 3.78569634e-01 -1.07899821 0.27902829 718.50 1.62220305e-01 -2.46836480e-01 2.95370403e-01 -0.98937802 0.14864020 718.75 -4.39659579e-02 -2.55494922e-01 2.59250189e-01 -1.74120885 0.08589749 719.00 -3.39063892e-01 -2.23461258e-01 4.06077895e-01 -2.55887921 0.18592495 719.25 -4.66759606e-01 -1.28127897e-01 4.84026123e-01 -2.87368660 0.31004836 719.50 -3.89767108e-01 -2.20736166e-01 4.47931751e-01 -2.62629976 0.32476752 719.75 -3.56411764e-01 -3.02747709e-01 4.67638237e-01 -2.43742819 0.38316279 720.00 -4.05031495e-01 -2.54323114e-01 4.78258046e-01 -2.58090387 0.39991370 720.25 -4.48303793e-01 -2.58731041e-01 5.17608001e-01 -2.61815663 0.45751986 720.50 -3.31805229e-01 -2.98967570e-01 4.46627717e-01 -2.40820694 0.54429136 720.75 -2.37026378e-01 -3.07127674e-01 3.87954780e-01 -2.22807396 0.54464848 721.00 -1.43098852e-01 -3.31079235e-01 3.60680941e-01 -1.97876590 0.50100619 721.25 -1.08657135e-01 -3.40393465e-01 3.57315104e-01 -1.87978285 0.45635025 721.50 9.07249741e-02 -2.51367246e-01 2.67238682e-01 -1.22442123 0.19447042 721.75 2.34643419e-01 -1.32586532e-01 2.69512009e-01 -0.51432854 0.17622394 722.00 2.44135413e-01 7.29336625e-02 2.54796820e-01 0.29030287 0.15818403 722.25 1.56122637e-01 5.01296708e-02 1.63973357e-01 0.31069285 0.06883217 722.50 -5.03164995e-02 9.15191900e-02 1.04439036e-01 2.07347967 0.02295892 722.75 -1.42491331e-01 1.06056804e-01 1.77628334e-01 2.50174725 0.08665975 723.00 -2.47462667e-01 1.09435828e-01 2.70580805e-01 2.72521762 0.15230863 723.25 -3.06135670e-01 7.59964515e-02 3.15427502e-01 2.89826704 0.13244378 723.50 -3.32748475e-01 -1.76414521e-03 3.32753151e-01 -3.13629097 0.15268360 723.75 -2.61382277e-01 5.29758526e-02 2.66696711e-01 2.94162557 0.10312974 724.00 -2.64524005e-01 -1.49295183e-02 2.64944975e-01 -3.08521328 0.10288073 724.25 -3.06095570e-01 -1.47296623e-01 3.39692203e-01 -2.69308873 0.17765594 724.50 -1.76178329e-01 -8.90800415e-02 1.97418483e-01 -2.67345575 0.17563255 724.75 -8.18227928e-02 -4.22129310e-02 9.20700873e-02 -2.66530078 0.06696783 725.00 7.72294862e-03 -1.82091738e-03 7.93471332e-03 -0.23155108 0.00101493 725.25 6.42000709e-02 3.50865588e-02 7.31622561e-02 0.50016673 0.08227746 725.50 1.93441694e-01 9.19946834e-02 2.14202499e-01 0.44391169 0.30925154 725.75 2.45547041e-01 1.67231557e-01 2.97085414e-01 0.59789916 0.45157386 726.00 2.98531139e-01 2.31244535e-01 3.77617367e-01 0.65906496 0.58377642 726.25 3.04870930e-01 2.48448758e-01 3.93284972e-01 0.68377911 0.62300569 726.50 3.08997459e-01 3.20208639e-01 4.44986519e-01 0.80321426 0.51766164 726.75 2.71810184e-01 4.40145234e-01 5.17309001e-01 1.01757474 0.54949243 727.00 2.15742141e-01 4.02831705e-01 4.56966141e-01 1.07910397 0.55070505 727.25 1.68118177e-01 3.44774381e-01 3.83579320e-01 1.11710333 0.47127138 727.50 1.40634379e-01 2.44682097e-01 2.82218633e-01 1.04913968 0.35463834 727.75 9.11346210e-02 2.83554151e-01 2.97839681e-01 1.25982293 0.39682819 728.00 3.76488367e-02 3.33091077e-01 3.35212024e-01 1.45824535 0.47367991 728.25 -4.64801699e-02 2.97401573e-01 3.01011797e-01 1.72582975 0.56689864 728.50 -8.45410306e-02 3.29964795e-01 3.40622888e-01 1.82161324 0.74865259 728.75 -7.02668477e-02 3.31977908e-01 3.39332818e-01 1.77937904 0.70777225 729.00 -9.47737416e-02 3.36830970e-01 3.49910224e-01 1.84507391 0.80882572 729.25 -1.00848067e-01 2.58664758e-01 2.77628870e-01 1.94254774 0.70986444 729.50 -7.86630419e-02 1.92075750e-01 2.07559553e-01 1.95950120 0.66950698 729.75 -9.21103840e-02 9.34215258e-02 1.31194147e-01 2.34912767 0.43738471 730.00 -9.37881419e-02 1.20115942e-02 9.45541853e-02 3.01421450 0.37291984 730.25 -1.32278263e-01 -9.86698915e-02 1.65025109e-01 -2.50070354 0.58627807 730.50 -1.88923403e-01 -1.50867448e-01 2.41770633e-01 -2.46772787 0.79386652 730.75 -2.01916392e-01 -2.37633659e-01 3.11833265e-01 -2.27511393 0.72854489 731.00 -2.45304499e-01 -2.97393545e-01 3.85509037e-01 -2.26050598 0.81839160 731.25 -2.37958169e-01 -3.38452324e-01 4.13731877e-01 -2.18358465 0.85394784 731.50 -2.36331072e-01 -3.45121072e-01 4.18283313e-01 -2.17123248 0.82175728 731.75 -2.74200329e-01 -3.20397628e-01 4.21711348e-01 -2.27865524 0.79237411 732.00 -2.88888770e-01 -3.19499199e-01 4.30739434e-01 -2.30592289 0.79698800 732.25 -2.70662739e-01 -3.32587711e-01 4.28804039e-01 -2.25390061 0.74481622 732.50 -2.77171163e-01 -3.91256398e-01 4.79484538e-01 -2.18714639 0.79518962 732.75 -1.98806640e-01 -3.92368832e-01 4.39860638e-01 -2.03977608 0.76652170 733.00 -1.61693535e-01 -3.80699710e-01 4.13614638e-01 -1.97243592 0.75551597 733.25 -2.03885824e-01 -4.05425149e-01 4.53805003e-01 -2.03675635 0.75487356 733.50 -1.58285468e-01 -4.23713025e-01 4.52312963e-01 -1.92831062 0.72240483 733.75 -2.60766588e-02 -3.89251969e-01 3.90124451e-01 -1.63768810 0.67866450 734.00 -6.51943138e-03 -3.81037371e-01 3.81093139e-01 -1.58790435 0.64228644 734.25 4.62830478e-02 -3.62868632e-01 3.65808372e-01 -1.44393365 0.54276371 734.50 7.53797650e-02 -3.99797821e-01 4.06841992e-01 -1.38443934 0.62679590 734.75 1.09077715e-01 -3.89081913e-01 4.04082520e-01 -1.29746643 0.56430711 735.00 1.15346146e-01 -3.41323908e-01 3.60287029e-01 -1.24490777 0.43214241 735.25 1.79453403e-01 -3.62982854e-01 4.04919839e-01 -1.11165052 0.40529398 735.50 1.42436383e-01 -3.24364246e-01 3.54260197e-01 -1.15702294 0.28342559 735.75 1.80016256e-01 -2.82547402e-01 3.35020726e-01 -1.00352981 0.36508173 736.00 1.97014605e-01 -2.65114502e-01 3.30303578e-01 -0.93170638 0.41492533 736.25 1.49551198e-01 -1.98081878e-01 2.48197485e-01 -0.92410488 0.33334418 736.50 1.76396899e-01 -1.45178107e-01 2.28456885e-01 -0.68862053 0.22895428 736.75 1.70021733e-01 9.58639019e-02 1.95185239e-01 0.51340166 0.21738117 737.00 1.97358982e-01 1.17583920e-01 2.29731465e-01 0.53731596 0.35494188 737.25 2.45619070e-01 1.69719100e-01 2.98552006e-01 0.60464999 0.54230922 737.50 2.37604890e-01 2.08585406e-01 3.16170769e-01 0.72045128 0.55639698 737.75 2.01015761e-01 2.54513828e-01 3.24321792e-01 0.90230413 0.64628216 738.00 1.68526506e-01 2.70068726e-01 3.18336771e-01 1.01290679 0.64846662 738.25 1.66547964e-01 2.95570211e-01 3.39263871e-01 1.05766257 0.76344082 738.50 8.28594176e-02 2.86644179e-01 2.98379906e-01 1.28939960 0.71948537 738.75 2.83222314e-02 2.87347068e-01 2.88739479e-01 1.47254912 0.77034411 739.00 2.20830807e-02 2.62957578e-01 2.63883214e-01 1.48701329 0.72950965 739.25 -1.37375815e-02 2.35136070e-01 2.35537030e-01 1.62915395 0.76007736 739.50 -3.56489388e-02 2.07625472e-01 2.10663674e-01 1.74083661 0.80881059 739.75 -4.64918940e-02 1.83563513e-01 1.89359604e-01 1.81885417 0.82538377 740.00 -5.85312207e-02 1.37751923e-01 1.49671293e-01 1.97258491 0.65969015 740.25 -7.98283760e-02 1.03094344e-01 1.30387934e-01 2.22968363 0.58262201 740.50 -1.04262099e-01 8.40010227e-02 1.33890840e-01 2.46340291 0.55983654 740.75 -1.08099023e-01 6.49789231e-02 1.26125569e-01 2.60036064 0.62887673 741.00 -1.02211943e-01 2.03708813e-02 1.04222138e-01 2.94486988 0.55625396 741.25 -1.08595219e-01 -3.19760463e-03 1.08642286e-01 -3.11215599 0.60851068 741.50 -1.06838276e-01 -4.14062014e-02 1.14581372e-01 -2.77185653 0.51352059 741.75 -1.14005485e-01 -7.01539649e-02 1.33861232e-01 -2.58995839 0.52359010 742.00 -9.11912832e-02 -1.35534324e-01 1.63356674e-01 -2.16305232 0.48999068 742.25 -9.77890313e-02 -2.16428920e-01 2.37495625e-01 -1.99517086 0.59537299 742.50 -1.13409058e-01 -1.76311577e-01 2.09636320e-01 -2.14239824 0.28361887 742.75 -1.63430763e-01 -9.03412226e-02 1.86738188e-01 -2.63661775 0.13201763 743.00 -1.70374629e-01 1.42873905e-01 2.22352124e-01 2.44376201 0.26413104 743.25 -1.66575632e-01 2.09011931e-01 2.67270328e-01 2.24368520 0.49255367 743.50 -1.28882666e-01 1.33713147e-01 1.85714693e-01 2.33780145 0.43320473 743.75 -1.39475733e-01 1.07062952e-01 1.75829337e-01 2.48691615 0.54714250 744.00 -1.81426949e-01 7.75010248e-02 1.97286965e-01 2.73788135 0.76326110 744.25 -1.70118327e-01 5.95359296e-02 1.80235325e-01 2.80494656 0.76237947 744.50 -1.27520817e-01 2.44783755e-02 1.29848949e-01 2.95194362 0.66651655 744.75 -1.16441595e-01 7.90788891e-03 1.16709810e-01 3.07378385 0.68124990 745.00 -1.27066001e-01 -2.47753938e-02 1.29458830e-01 -2.94902815 0.76625396 745.25 -1.25815120e-01 -3.60230195e-02 1.30870556e-01 -2.86273577 0.74240636 745.50 -1.13804418e-01 -7.97713186e-02 1.38978088e-01 -2.53022873 0.77724622 745.75 -1.13482131e-01 -9.79468695e-02 1.49905915e-01 -2.42954012 0.80596396 746.00 -1.02679900e-01 -1.35439177e-01 1.69961562e-01 -2.21947753 0.86682776 746.25 -1.04418036e-01 -1.53539239e-01 1.85680974e-01 -2.16802354 0.86614593 746.50 -8.89281372e-02 -1.72153028e-01 1.93765009e-01 -2.04760752 0.79158770 746.75 -9.37561303e-02 -1.96631053e-01 2.17839352e-01 -2.01572240 0.75999956 747.00 -1.66631159e-01 -2.44154181e-01 2.95596359e-01 -2.16966915 0.78853541 747.25 -1.79658161e-01 -2.53977386e-01 3.11097360e-01 -2.18645721 0.78440015 747.50 -1.95962010e-01 -2.40000918e-01 3.09841169e-01 -2.25552073 0.74431180 747.75 -2.12113245e-01 -1.91520256e-01 2.85783199e-01 -2.40716932 0.69255956 748.00 -2.11829739e-01 -1.96980180e-01 2.89262908e-01 -2.39250240 0.72718322 748.25 -1.78433737e-01 -2.22354654e-01 2.85096809e-01 -2.24704374 0.71101986 748.50 -1.46373618e-01 -2.40952468e-01 2.81927877e-01 -2.11669712 0.63335114 748.75 -1.76396542e-01 -2.71982801e-01 3.24176471e-01 -2.14615697 0.62108253 749.00 -2.14602728e-01 -3.19948913e-01 3.85255290e-01 -2.16161405 0.60887918 749.25 -2.69512320e-01 -4.00882520e-01 4.83056607e-01 -2.16268708 0.57905500 749.50 -3.78689542e-01 -4.71617124e-01 6.04837565e-01 -2.24733936 0.65058763 749.75 -4.51751938e-01 -3.23357105e-01 5.55553445e-01 -2.52035133 0.35972800 750.00 -4.67226785e-01 -1.25098058e-01 4.83684187e-01 -2.87998295 0.20207083 750.25 -5.12883256e-01 1.98850005e-01 5.50082320e-01 2.77172573 0.42216605 750.50 -5.05442483e-01 1.80976411e-01 5.36865500e-01 2.79775963 0.59918501 750.75 -4.85363338e-01 1.50066770e-01 5.08033075e-01 2.84173125 0.63180835 751.00 -4.50786442e-01 2.09320443e-01 4.97014551e-01 2.70687364 0.60078683 751.25 -3.60949615e-01 1.84509772e-01 4.05374494e-01 2.66904209 0.47797233 751.50 -3.62690387e-01 1.81764038e-01 4.05687666e-01 2.67702161 0.43075844 751.75 -4.43106302e-01 2.02978033e-01 4.87384116e-01 2.71203994 0.54184899 752.00 -3.49327737e-01 1.72159551e-01 3.89446759e-01 2.68369664 0.41279484 752.25 -3.30374629e-01 2.17918192e-01 3.95772326e-01 2.55849182 0.48155928 752.50 -3.05523113e-01 2.46003075e-01 3.92252324e-01 2.46369722 0.45335356 752.75 -2.81136259e-01 1.76389498e-01 3.31889818e-01 2.58125759 0.40277958 753.00 -2.93854028e-01 2.10564791e-01 3.61507567e-01 2.51983716 0.48786178 753.25 -2.05746601e-01 1.42734121e-01 2.50409051e-01 2.53508213 0.29148398 753.50 -1.53726729e-01 1.80027853e-01 2.36731778e-01 2.27755323 0.35845001 753.75 -5.04725527e-02 9.97030339e-02 1.11750497e-01 2.03941459 0.11908379 754.00 -1.85056003e-02 5.25642227e-02 5.57266072e-02 1.90930245 0.02848762 754.25 -1.04972468e-02 2.17784831e-02 2.41763214e-02 2.01994119 0.00502507 754.50 1.11114044e-02 -1.13761772e-02 1.59022236e-02 -0.79717180 0.00320810 754.75 1.70745486e-03 -9.52198498e-02 9.52351574e-02 -1.55286654 0.12604771 755.00 -7.38979804e-02 -1.37539441e-01 1.56134587e-01 -2.06382574 0.29637649 755.25 -2.44570990e-01 -2.05732480e-01 3.19594778e-01 -2.44223120 0.60212805 755.50 -2.82891279e-01 -2.29362972e-01 3.64190676e-01 -2.46031221 0.58558824 755.75 -4.05860308e-01 -1.82178538e-01 4.44872576e-01 -2.71967879 0.51296111 756.00 -4.32232307e-01 -1.36675467e-01 4.53326538e-01 -2.83533293 0.46342625 756.25 -4.02119135e-01 3.69400969e-02 4.03812295e-01 3.04998620 0.30037767 756.50 -3.61641874e-01 1.63634661e-01 3.96939727e-01 2.71668069 0.26569890 756.75 -3.03256246e-01 4.05636754e-01 5.06463747e-01 2.21276316 0.29165506 757.00 -2.59501146e-01 4.31870957e-01 5.03838633e-01 2.11186013 0.32843200 757.25 -4.75075704e-02 4.94313090e-01 4.96590778e-01 1.66661030 0.37179183 757.50 8.13992308e-02 5.91624565e-01 5.97198008e-01 1.43406881 0.52220466 757.75 1.01711411e-01 7.60992406e-01 7.67759503e-01 1.43792751 0.73916722 758.00 1.61941591e-01 7.41922743e-01 7.59390832e-01 1.35589403 0.83964900 758.25 2.27286613e-01 7.14620820e-01 7.49894740e-01 1.26286139 0.89972559 758.50 2.62145159e-01 6.76276077e-01 7.25306430e-01 1.20099868 0.91234950 758.75 3.01728935e-01 6.53986820e-01 7.20235455e-01 1.13852865 0.94316033 759.00 3.49597804e-01 6.11332883e-01 7.04234704e-01 1.05132383 0.94024306 759.25 3.96828668e-01 5.65193328e-01 6.90591406e-01 0.95865473 0.95462112 759.50 4.04665276e-01 5.23196142e-01 6.61428900e-01 0.91245629 0.94824183 759.75 4.10968723e-01 4.61612449e-01 6.18046393e-01 0.84337211 0.92988811 760.00 4.37675926e-01 3.31615350e-01 5.49116524e-01 0.64839394 0.90877559 760.25 4.37119693e-01 2.60483840e-01 5.08847185e-01 0.53740646 0.94259779 760.50 4.02359985e-01 2.00730458e-01 4.49651280e-01 0.46275341 0.90885962 760.75 3.86991056e-01 1.46747205e-01 4.13880200e-01 0.36244821 0.92508765 761.00 3.36678742e-01 1.21740420e-01 3.58012996e-01 0.34696442 0.92482563 761.25 2.97075241e-01 1.06177959e-01 3.15479726e-01 0.34326173 0.93739195 761.50 2.64129983e-01 9.10822821e-02 2.79393325e-01 0.33206954 0.90215654 761.75 2.41528480e-01 7.92024323e-02 2.54183068e-01 0.31687221 0.87429640 762.00 2.23547919e-01 7.36767210e-02 2.35376149e-01 0.31836794 0.87745565 762.25 2.12495182e-01 5.37723836e-02 2.19193229e-01 0.24784930 0.87415999 762.50 1.78178312e-01 4.17290590e-02 1.82999523e-01 0.23005209 0.82401907 762.75 1.49550166e-01 3.73015531e-02 1.54131950e-01 0.24443743 0.77902233 763.00 1.04280069e-01 4.53542507e-02 1.13716053e-01 0.41024904 0.75053315 763.25 9.39547813e-02 5.18961076e-02 1.07334556e-01 0.50464714 0.75013545 763.50 5.78300637e-02 8.42001392e-02 1.02146854e-01 0.96897310 0.70154108 763.75 4.71358876e-02 9.62673840e-02 1.07187691e-01 1.11547499 0.81102557 764.00 4.44608326e-02 1.23153416e-01 1.30933301e-01 1.22433816 0.85158063 764.25 3.99835789e-02 1.49272427e-01 1.54534604e-01 1.30908349 0.90791685 764.50 3.96263476e-02 1.95343904e-01 1.99322573e-01 1.37065778 0.94678816 764.75 5.45699822e-02 2.06173926e-01 2.13273464e-01 1.31205022 0.95861153 765.00 8.43254955e-02 2.26467386e-01 2.41657332e-01 1.21434955 0.97061588 765.25 9.67960471e-02 2.30140369e-01 2.49667908e-01 1.17266208 0.97185619 765.50 1.17618573e-01 2.21586547e-01 2.50867946e-01 1.08281186 0.97519757 765.75 1.29050769e-01 2.15256964e-01 2.50977412e-01 1.03073014 0.97393220 766.00 1.39882241e-01 2.05916982e-01 2.48935423e-01 0.97408907 0.97402467 766.25 1.48994991e-01 2.03769535e-01 2.52431240e-01 0.93944032 0.97108978 766.50 1.57709698e-01 2.08350365e-01 2.61308675e-01 0.92286542 0.97294461 766.75 1.66003137e-01 2.11062178e-01 2.68522410e-01 0.90433347 0.96839606 767.00 1.89883536e-01 2.08659674e-01 2.82125179e-01 0.83247528 0.96989160 767.25 2.04699717e-01 2.09692450e-01 2.93040778e-01 0.79744591 0.97331041 767.50 2.26368140e-01 2.06791460e-01 3.06602745e-01 0.74023382 0.98602455 767.75 2.35840260e-01 2.01205064e-01 3.10006623e-01 0.70631492 0.97972527 768.00 2.72988509e-01 1.86318209e-01 3.30510516e-01 0.59889307 0.95136167 768.25 2.95578100e-01 1.57153915e-01 3.34759266e-01 0.48867175 0.93809708 768.50 3.22134000e-01 1.09890432e-01 3.40361897e-01 0.32875346 0.95517464 768.75 3.16682880e-01 7.48142742e-02 3.25400095e-01 0.23199006 0.93838359 769.00 2.84238489e-01 2.58689668e-02 2.85413247e-01 0.09076144 0.91195410 769.25 2.55747940e-01 -1.58498839e-02 2.56238615e-01 -0.06189547 0.86606998 769.50 2.12223315e-01 -6.27650828e-02 2.21310169e-01 -0.28755333 0.83768628 769.75 1.65262189e-01 -5.57120379e-02 1.74400179e-01 -0.32514842 0.63700390 770.00 1.04588056e-01 -7.77588334e-02 1.30326888e-01 -0.63931342 0.36666362 770.25 1.04896424e-01 -3.93683536e-02 1.12040738e-01 -0.35903972 0.22667647 770.50 1.18837533e-01 6.06401909e-02 1.33415111e-01 0.47183624 0.23592698 770.75 1.63976076e-01 1.31567283e-01 2.10233450e-01 0.67617623 0.52031228 771.00 2.08824444e-01 1.34832898e-01 2.48571033e-01 0.57332938 0.71546861 771.25 2.30157094e-01 1.05828003e-01 2.53321642e-01 0.43098001 0.78254978 771.50 2.22932738e-01 7.90548688e-02 2.36534729e-01 0.34077856 0.83783230 771.75 2.35179391e-01 8.50785496e-02 2.50095393e-01 0.34711298 0.89931661 772.00 2.31035451e-01 7.72340970e-02 2.43603131e-01 0.32261620 0.93051617 772.25 2.11247951e-01 5.86457888e-02 2.19237372e-01 0.27079656 0.90830045 772.50 2.01572999e-01 5.18326421e-02 2.08130480e-01 0.25168804 0.90279736 772.75 1.81148931e-01 5.11702233e-02 1.88237422e-01 0.27530321 0.86942363 773.00 1.63351248e-01 6.24756112e-02 1.74890915e-01 0.36529642 0.84527698 773.25 1.76571603e-01 6.31248058e-02 1.87516058e-01 0.34334295 0.87002541 773.50 1.71422633e-01 5.44363650e-02 1.79858380e-01 0.30748481 0.88339108 773.75 1.54112154e-01 6.69858664e-02 1.68040657e-01 0.41002137 0.84296324 774.00 1.48746882e-01 7.82970925e-02 1.68095419e-01 0.48452668 0.83414196 774.25 1.63057388e-01 9.78895330e-02 1.90184312e-01 0.54066793 0.84745031 774.50 1.70312846e-01 1.04847192e-01 1.99998498e-01 0.55182228 0.86997767 774.75 1.59345461e-01 1.11388575e-01 1.94418082e-01 0.61008021 0.83459666 775.00 1.82579238e-01 1.20670698e-01 2.18852909e-01 0.58401521 0.86533383 775.25 2.20898880e-01 1.18154422e-01 2.50513039e-01 0.49116081 0.92231422 775.50 2.26960421e-01 1.15501865e-01 2.54659996e-01 0.47074821 0.92636927 775.75 2.71322544e-01 1.00420631e-01 2.89309913e-01 0.35448135 0.92645882 776.00 3.01375507e-01 8.17778439e-02 3.12273617e-01 0.26496844 0.93794773 776.25 3.21935089e-01 4.58137252e-02 3.25178564e-01 0.14135820 0.95623650 776.50 3.23542080e-01 2.45275174e-02 3.24470455e-01 0.07566463 0.95724048 776.75 2.83722122e-01 -2.46858860e-02 2.84794023e-01 -0.08678870 0.96132246 777.00 2.69470899e-01 -3.81947516e-02 2.72164297e-01 -0.14080189 0.96345041 777.25 2.58608600e-01 -6.04834652e-02 2.65587382e-01 -0.22975063 0.95288219 777.50 2.44482222e-01 -6.56449102e-02 2.53141880e-01 -0.26231870 0.93789843 777.75 2.17535620e-01 -6.13141164e-02 2.26011431e-01 -0.27473063 0.92637344 778.00 2.01271425e-01 -6.81333565e-02 2.12490801e-01 -0.32640660 0.93527436 778.25 1.78660297e-01 -6.80676160e-02 1.91187610e-01 -0.36401097 0.96233207 778.50 1.73775331e-01 -6.24142664e-02 1.84643999e-01 -0.34481746 0.96835466 778.75 1.69970870e-01 -6.22466576e-02 1.81010340e-01 -0.35105062 0.96430844 779.00 1.62742820e-01 -5.74330906e-02 1.72579794e-01 -0.33926228 0.95577842 779.25 1.55444721e-01 -5.20806046e-02 1.63937338e-01 -0.32328811 0.96295850 779.50 1.53451745e-01 -5.35654091e-02 1.62532124e-01 -0.33584612 0.94593981 779.75 1.48051091e-01 -5.55209478e-02 1.58119263e-01 -0.35878126 0.95647674 780.00 1.38611009e-01 -6.20869237e-02 1.51880867e-01 -0.42112454 0.95083994 780.25 1.21799217e-01 -6.25473140e-02 1.36920472e-01 -0.47441138 0.96347611 780.50 1.13130663e-01 -5.87952908e-02 1.27496797e-01 -0.47929206 0.95759587 780.75 9.81766602e-02 -5.60558044e-02 1.13052686e-01 -0.51879941 0.94843920 781.00 9.29716919e-02 -4.27694571e-02 1.02337490e-01 -0.43116075 0.92006378 781.25 9.64576605e-02 -3.19488024e-02 1.01611054e-01 -0.31984825 0.92785137 781.50 1.01228341e-01 -2.07485525e-02 1.03332857e-01 -0.20216772 0.92337240 781.75 1.00600096e-01 -1.68467017e-02 1.02000934e-01 -0.16592250 0.93211145 782.00 9.68933476e-02 -1.88695165e-02 9.87136234e-02 -0.19233782 0.93407146 782.25 9.35368198e-02 -2.08899304e-02 9.58411491e-02 -0.21972793 0.91974189 782.50 8.84699443e-02 -1.78329311e-02 9.02493461e-02 -0.19890520 0.84803652 782.75 7.78250619e-02 -1.71885792e-02 7.97006118e-02 -0.21737212 0.80505956 783.00 7.22663187e-02 -4.73330296e-03 7.24211638e-02 -0.06540463 0.73199361 783.25 6.22157664e-02 1.93861811e-02 6.51661385e-02 0.30206104 0.57581310 783.50 7.14830068e-02 4.36814351e-02 8.37728359e-02 0.54852267 0.75256143 783.75 7.31263002e-02 5.21408189e-02 8.98115849e-02 0.61941363 0.80138160 784.00 7.62063331e-02 6.95042994e-02 1.03141906e-01 0.73943506 0.71693687 784.25 9.83338650e-02 8.03681261e-02 1.26998365e-01 0.68520020 0.77226411 784.50 1.35392513e-01 8.13142578e-02 1.57933977e-01 0.54084707 0.89046176 784.75 1.46943126e-01 7.83810449e-02 1.66540897e-01 0.49001761 0.90897342 785.00 1.66111928e-01 6.55842566e-02 1.78590222e-01 0.37603261 0.91011469 785.25 1.79477230e-01 6.12924532e-02 1.89654531e-01 0.32908735 0.94413542 785.50 1.90139531e-01 5.14407164e-02 1.96975097e-01 0.26421688 0.95597084 785.75 1.97143562e-01 3.83343973e-02 2.00836027e-01 0.19205255 0.95231356 786.00 2.03250253e-01 2.13125048e-02 2.04364597e-01 0.10447664 0.96334292 786.25 1.98001062e-01 9.32729707e-03 1.98220632e-01 0.04707251 0.95667866 786.50 1.89058766e-01 -1.49980496e-02 1.89652732e-01 -0.07916430 0.96519974 786.75 1.91199715e-01 -2.02212127e-02 1.92266035e-01 -0.10536795 0.97323648 787.00 1.77327597e-01 -3.50042325e-02 1.80749476e-01 -0.19489304 0.96405237 787.25 1.66296067e-01 -4.27123629e-02 1.71693704e-01 -0.25141085 0.96058780 787.50 1.48762207e-01 -4.22944643e-02 1.54657738e-01 -0.27700014 0.95913090 787.75 1.40319553e-01 -3.74334148e-02 1.45226849e-01 -0.26070131 0.95618724 788.00 1.21226707e-01 -3.08034211e-02 1.25079036e-01 -0.24883154 0.94010057 788.25 1.16312323e-01 -2.66436316e-02 1.19324933e-01 -0.22518467 0.95338145 788.50 1.14276008e-01 -2.19574922e-02 1.16366394e-01 -0.18983079 0.96076229 788.75 1.14948615e-01 -1.49448325e-02 1.15916056e-01 -0.12928794 0.95479363 789.00 1.15018241e-01 -9.80426273e-03 1.15435347e-01 -0.08503538 0.96467282 789.25 1.14955280e-01 -4.30466536e-03 1.15035849e-01 -0.03742895 0.96569402 789.50 1.14329360e-01 4.92003385e-03 1.14435175e-01 0.04300733 0.96618692 789.75 1.24719006e-01 1.11842903e-02 1.25219483e-01 0.08943668 0.96049480 790.00 1.42020154e-01 1.32763910e-02 1.42639359e-01 0.09321155 0.97823726 790.25 1.49525368e-01 1.16183121e-02 1.49976068e-01 0.07754547 0.97774272 790.50 1.56681475e-01 4.36307616e-03 1.56742212e-01 0.02783960 0.96759245 790.75 1.56362406e-01 -1.32169284e-02 1.56920009e-01 -0.08432708 0.96671515 791.00 1.54399506e-01 -3.11631043e-02 1.57513005e-01 -0.19915861 0.97342016 791.25 1.45829014e-01 -4.49635459e-02 1.52603479e-01 -0.29908191 0.94935124 791.50 1.33712608e-01 -6.06502516e-02 1.46824775e-01 -0.42583257 0.93671646 791.75 1.15664449e-01 -5.91571185e-02 1.29914700e-01 -0.47276927 0.90134537 792.00 9.38460722e-02 -5.77302527e-02 1.10181066e-01 -0.55149130 0.86632653 792.25 7.55638331e-02 -5.15581984e-02 9.14775420e-02 -0.59875672 0.75874572 792.50 5.82676778e-02 -3.96140254e-02 7.04584507e-02 -0.59708282 0.66946070 792.75 5.29387911e-02 -2.13234367e-02 5.70719244e-02 -0.38291283 0.58665614 793.00 4.41240507e-02 -1.02751667e-02 4.53046454e-02 -0.22879246 0.42361485 793.25 4.16438342e-02 2.68007019e-02 4.95225862e-02 0.57184137 0.43311050 793.50 4.41678044e-02 5.64030397e-02 7.16386616e-02 0.90646111 0.62541343 793.75 6.25794848e-02 7.07928224e-02 9.44871188e-02 0.84690252 0.74233309 794.00 7.77970976e-02 8.89095701e-02 1.18141018e-01 0.85195853 0.85062301 794.25 9.18304218e-02 1.04765855e-01 1.39315149e-01 0.85110040 0.89782180 794.50 1.04944763e-01 1.00946330e-01 1.45614439e-01 0.76598047 0.93709115 794.75 1.29670780e-01 1.00027213e-01 1.63767990e-01 0.65705303 0.92666112 795.00 1.50330270e-01 9.76274742e-02 1.79249306e-01 0.57596733 0.94380741 795.25 1.71762095e-01 8.55566963e-02 1.91891025e-01 0.46213577 0.95009832 795.50 1.84083875e-01 8.41797649e-02 2.02418146e-01 0.42889995 0.93674240 795.75 2.18958918e-01 6.58136322e-02 2.28636047e-01 0.29198447 0.94151655 796.00 2.32624297e-01 5.31332500e-02 2.38615183e-01 0.22455585 0.93024137 796.25 2.64186332e-01 4.27620955e-03 2.64220938e-01 0.01618493 0.93714705 796.50 2.77019087e-01 -1.62340320e-02 2.77494357e-01 -0.05853563 0.94054433 796.75 2.85889884e-01 -6.10099123e-02 2.92327274e-01 -0.21024973 0.92906539 797.00 2.89980922e-01 -9.62021724e-02 3.05522164e-01 -0.32032799 0.92289970 797.25 2.59054577e-01 -1.71030145e-01 3.10420013e-01 -0.58351853 0.90241360 797.50 2.39278627e-01 -2.03869469e-01 3.14351749e-01 -0.70566390 0.90955159 797.75 1.79336701e-01 -2.52484311e-01 3.09693364e-01 -0.95319865 0.89041597 798.00 1.26393410e-01 -2.72543854e-01 3.00425442e-01 -1.13656330 0.83688310 798.25 1.68933128e-02 -2.79351696e-01 2.79862027e-01 -1.51039660 0.77305429 798.50 -1.83778665e-02 -2.75647921e-01 2.76259882e-01 -1.63736932 0.72663223 798.75 -1.50251084e-01 -2.37935436e-01 2.81404797e-01 -2.13404070 0.57199053 799.00 -2.23541682e-01 -2.33893710e-01 3.23538485e-01 -2.33356777 0.54040724 799.25 -3.88290704e-01 -1.23667395e-01 4.07508645e-01 -2.83325844 0.65755314 799.50 -3.93175256e-01 -4.59331806e-02 3.95849263e-01 -3.02529361 0.53093605 799.75 -3.97639165e-01 1.87833751e-01 4.39770876e-01 2.70029042 0.46303142 800.00 -3.10471946e-01 2.74418319e-01 4.14364867e-01 2.41775829 0.32282975 800.25 1.38495126e-02 3.36018879e-01 3.36304172e-01 1.52960317 0.17843042 800.50 1.81834249e-01 2.93712481e-01 3.45442782e-01 1.01645871 0.26156669 800.75 2.48219205e-01 2.63725054e-01 3.62165264e-01 0.81567707 0.47795106 801.00 2.97691652e-01 2.48005548e-01 3.87462349e-01 0.69459784 0.61609503 801.25 3.32606897e-01 2.53432990e-01 4.18157421e-01 0.65111136 0.73410545 801.50 3.60892662e-01 1.67484671e-01 3.97862575e-01 0.43450463 0.71601620 801.75 3.57505835e-01 1.28337438e-01 3.79843284e-01 0.34465230 0.76175939 802.00 3.94981240e-01 1.04345307e-01 4.08531667e-01 0.25827740 0.78794155 802.25 4.07425372e-01 6.21313359e-02 4.12135580e-01 0.15133156 0.84324237 802.50 3.87252383e-01 4.94473183e-02 3.90396523e-01 0.12700034 0.86906282 802.75 3.90016609e-01 2.61560869e-02 3.90892692e-01 0.06696376 0.88377381 803.00 3.56540851e-01 -1.12671879e-02 3.56718836e-01 -0.03159088 0.85615079 803.25 3.38838415e-01 -3.57437131e-02 3.40718483e-01 -0.10510026 0.88089352 803.50 3.42788735e-01 -5.99139615e-02 3.47985344e-01 -0.17303601 0.85911903 803.75 3.55565268e-01 -8.67305305e-02 3.65990225e-01 -0.23925096 0.89004481 804.00 3.43450846e-01 -1.52676944e-01 3.75857331e-01 -0.41830243 0.90147143 804.25 3.03455618e-01 -1.79591711e-01 3.52616640e-01 -0.53438456 0.89696940 804.50 2.67762696e-01 -1.91192931e-01 3.29016106e-01 -0.62008591 0.87416884 804.75 2.53983284e-01 -1.87624093e-01 3.15769392e-01 -0.63624671 0.88450721 805.00 2.13708682e-01 -2.00354444e-01 2.92939079e-01 -0.75315764 0.88049132 805.25 1.88392338e-01 -2.18898872e-01 2.88805106e-01 -0.86015960 0.84180741 805.50 1.45837730e-01 -2.13002933e-01 2.58145100e-01 -0.97042998 0.84597885 805.75 1.14517008e-01 -2.16232224e-01 2.44684531e-01 -1.08374855 0.82443176 806.00 7.12805533e-02 -2.34448445e-01 2.45044875e-01 -1.27564174 0.82440970 806.25 5.72798393e-02 -2.37922045e-01 2.44720002e-01 -1.33454189 0.81256713 806.50 -2.20179763e-02 -2.39135586e-01 2.40147079e-01 -1.66261065 0.78673612 806.75 -6.71181405e-02 -2.30981103e-01 2.40535060e-01 -1.85358728 0.76134502 807.00 -1.24705921e-01 -2.05199632e-01 2.40121752e-01 -2.11688009 0.72765534 807.25 -1.66348058e-01 -1.91154677e-01 2.53400448e-01 -2.28691692 0.74883662 807.50 -2.06887581e-01 -8.45326849e-02 2.23491042e-01 -2.75370109 0.71124979 807.75 -2.03934298e-01 -3.15612274e-02 2.06362082e-01 -2.98804903 0.66044172 808.00 -2.12432639e-01 9.23207398e-02 2.31626305e-01 2.73162874 0.66688127 808.25 -2.03930017e-01 1.28019866e-01 2.40783176e-01 2.58100841 0.61696652 808.50 -1.27984559e-01 1.95210805e-01 2.33425161e-01 2.15111381 0.46976982 808.75 -9.93137972e-02 2.63969737e-01 2.82034133e-01 1.93064645 0.54851793 809.00 -3.69066829e-02 3.11926860e-01 3.14102641e-01 1.68856718 0.62236589 809.25 1.37109438e-02 3.29236420e-01 3.29521790e-01 1.52917570 0.64234736 809.50 1.52755770e-01 3.56129454e-01 3.87508082e-01 1.16559889 0.67804799 809.75 1.70868572e-01 3.39628317e-01 3.80188720e-01 1.10466812 0.71171535 810.00 2.36177967e-01 3.03087210e-01 3.84241967e-01 0.90884213 0.75974755 810.25 2.73959019e-01 2.53934072e-01 3.73545254e-01 0.74748263 0.72660236 810.50 2.86221900e-01 1.74922877e-01 3.35441483e-01 0.54857355 0.75285727 810.75 3.12053093e-01 1.49576991e-01 3.46049721e-01 0.44697681 0.81935899 811.00 3.42094308e-01 1.00371748e-01 3.56515081e-01 0.28539424 0.78223662 811.25 3.20128164e-01 7.13107281e-02 3.27974483e-01 0.21917832 0.68316338 811.50 3.43394478e-01 3.25155026e-02 3.44930465e-01 0.09440701 0.76394475 811.75 3.18643738e-01 1.04177273e-02 3.18813991e-01 0.03268232 0.80185141 812.00 3.05487762e-01 -4.90643441e-02 3.09402784e-01 -0.15924983 0.84768821 812.25 3.03300065e-01 -6.03765681e-02 3.09251127e-01 -0.19649681 0.88790058 812.50 2.93920155e-01 -4.87228052e-02 2.97931148e-01 -0.16427500 0.88304589 812.75 2.81389966e-01 -6.69689495e-02 2.89249292e-01 -0.23364679 0.87651522 813.00 2.66906695e-01 -7.19325892e-02 2.76429885e-01 -0.26325006 0.89224334 813.25 2.56337941e-01 -5.71130130e-02 2.62623373e-01 -0.21922288 0.89937517 813.50 2.44695433e-01 -3.89900893e-02 2.47782327e-01 -0.15801294 0.88293754 813.75 2.45979602e-01 -3.97123216e-02 2.49164671e-01 -0.16006445 0.88125188 814.00 2.46473112e-01 -4.40945058e-02 2.50386343e-01 -0.17702909 0.88874906 814.25 2.76551407e-01 -4.96317396e-02 2.80969732e-01 -0.17757623 0.91450448 814.50 2.89913903e-01 -5.30600915e-02 2.94729443e-01 -0.18101678 0.90508813 814.75 2.76643057e-01 -5.98607830e-02 2.83045393e-01 -0.21309743 0.87230444 815.00 2.91367853e-01 -6.24892544e-02 2.97993511e-01 -0.21126818 0.86979913 815.25 3.19255448e-01 -8.48197335e-02 3.30330786e-01 -0.25968085 0.85296543 815.50 3.31011695e-01 -1.16286766e-01 3.50843775e-01 -0.33783882 0.86775311 815.75 3.03393713e-01 -1.85830161e-01 3.55781665e-01 -0.54956364 0.79220564 816.00 2.77869813e-01 -2.10349543e-01 3.48509058e-01 -0.64797087 0.79994856 816.25 2.36307672e-01 -2.81407345e-01 3.67466202e-01 -0.87229174 0.89565841 816.50 2.26514336e-01 -2.93392024e-01 3.70658366e-01 -0.91332974 0.91846976 816.75 1.80915099e-01 -3.02104144e-01 3.52132343e-01 -1.03122276 0.83554165 817.00 1.36291152e-01 -2.90994929e-01 3.21330557e-01 -1.13277740 0.80060937 817.25 9.18441787e-02 -2.53608882e-01 2.69727303e-01 -1.22333969 0.69318241 817.50 7.89160658e-02 -2.45954839e-01 2.58305107e-01 -1.26031716 0.70785156 817.75 6.45228472e-02 -2.50456852e-01 2.58634554e-01 -1.31865828 0.81407439 818.00 4.15976861e-02 -2.44527125e-01 2.48040082e-01 -1.40229458 0.77857227 818.25 -2.55976739e-02 -2.34890266e-01 2.36280930e-01 -1.67934513 0.70593515 818.50 -4.12291635e-02 -2.03779595e-01 2.07908555e-01 -1.77042390 0.66391801 818.75 -9.34387006e-02 -1.41434347e-01 1.69512434e-01 -2.15462246 0.58807918 819.00 -9.09596937e-02 -8.85278628e-02 1.26928517e-01 -2.36974241 0.48823679 819.25 -4.95093560e-02 -1.52523111e-02 5.18054951e-02 -2.84274940 0.20992317 819.50 -1.48733163e-02 3.24169106e-03 1.52224866e-02 2.92699522 0.02839070 819.75 4.45009427e-02 2.08239126e-02 4.91321609e-02 0.43767488 0.29438056 820.00 5.90112099e-02 1.18407433e-02 6.01874247e-02 0.19802283 0.38310463 820.25 8.22858890e-02 -4.12720259e-03 8.23893278e-02 -0.05011487 0.59009513 820.50 9.62989938e-02 -9.49811661e-03 9.67662670e-02 -0.09831354 0.68971504 820.75 1.12045777e-01 -1.83904527e-02 1.13544991e-01 -0.16268285 0.78231939 821.00 1.23012781e-01 -2.59972528e-02 1.25729874e-01 -0.20827316 0.81318940 821.25 1.37890803e-01 -3.03283659e-02 1.41186697e-01 -0.21649766 0.80405300 821.50 1.53319571e-01 -4.46667080e-02 1.59693474e-01 -0.28348451 0.87577215 821.75 1.60036290e-01 -7.18278717e-02 1.75416240e-01 -0.42187420 0.93981709 822.00 1.53032375e-01 -8.59704821e-02 1.75527296e-01 -0.51184212 0.92203450 822.25 1.49752948e-01 -9.91232194e-02 1.79586631e-01 -0.58470343 0.89193683 822.50 1.39434298e-01 -1.14134897e-01 1.80190727e-01 -0.68595411 0.89473217 822.75 1.21968286e-01 -1.33617043e-01 1.80913728e-01 -0.83094343 0.91089636 823.00 1.01750602e-01 -1.29410508e-01 1.64621580e-01 -0.90448835 0.89187159 823.25 8.04832910e-02 -1.24147932e-01 1.47953605e-01 -0.99562740 0.89320071 823.50 7.35232443e-02 -1.05343631e-01 1.28463801e-01 -0.96145610 0.87795778 823.75 7.86904491e-02 -9.79485304e-02 1.25642753e-01 -0.89399434 0.87173653 824.00 8.60705280e-02 -1.13683965e-01 1.42590952e-01 -0.92276445 0.85738500 824.25 8.08919019e-02 -1.18519987e-01 1.43493857e-01 -0.97190056 0.90589652 824.50 7.34079875e-02 -1.20005658e-01 1.40677257e-01 -1.02181508 0.87234802 824.75 7.33870520e-02 -1.25506724e-01 1.45387747e-01 -1.04168338 0.86181405 825.00 6.63532369e-02 -1.27751929e-01 1.43955922e-01 -1.09175632 0.85226324 825.25 4.96818256e-02 -1.34630428e-01 1.43504829e-01 -1.21727537 0.83981865 825.50 2.30052126e-02 -1.46081755e-01 1.47882112e-01 -1.41459740 0.81969807 825.75 1.44981000e-02 -1.54761799e-01 1.55439407e-01 -1.47738884 0.82332279 826.00 -1.29246392e-02 -1.57022964e-01 1.57553982e-01 -1.65292170 0.79254661 826.25 -2.23468410e-02 -1.47646167e-01 1.49327734e-01 -1.72101024 0.76027923 826.50 -2.22634643e-02 -1.26899402e-01 1.28837572e-01 -1.74447067 0.54180119 826.75 -3.40144462e-02 -1.23576398e-01 1.28172184e-01 -1.83939527 0.56876768 827.00 -6.93569029e-02 -1.12146344e-01 1.31860466e-01 -2.12467163 0.58576253 827.25 -9.35628806e-02 -9.31546335e-02 1.32029536e-01 -2.35838093 0.57400962 827.50 -1.29381948e-01 -3.68539042e-02 1.34528431e-01 -2.86409612 0.60349070 827.75 -1.44784681e-01 -3.08324137e-02 1.48031218e-01 -2.93177333 0.63290219 828.00 -1.57122854e-01 6.36283345e-03 1.57251635e-01 3.10111886 0.61373268 828.25 -1.71856607e-01 2.15795835e-02 1.73206154e-01 3.01667905 0.73057534 828.50 -1.68759548e-01 5.17383898e-02 1.76512453e-01 2.84410967 0.62115181 828.75 -1.61418081e-01 9.32528669e-02 1.86418599e-01 2.61772399 0.60252326 829.00 -1.65090730e-01 1.67330646e-01 2.35062745e-01 2.34945641 0.74544318 829.25 -1.48513177e-01 1.96639810e-01 2.46421141e-01 2.21765209 0.73104193 829.50 -1.01365238e-01 2.75195076e-01 2.93269912e-01 1.92371497 0.76549677 829.75 -4.45575647e-02 3.02895925e-01 3.06155708e-01 1.71685398 0.79356726 830.00 6.21054488e-02 2.89715654e-01 2.96297565e-01 1.35962537 0.86311414 830.25 1.01273340e-01 2.84534454e-01 3.02020107e-01 1.22885160 0.86781923 830.50 1.44083407e-01 2.42484552e-01 2.82061671e-01 1.03465523 0.82508344 830.75 1.64457473e-01 2.06538261e-01 2.64015745e-01 0.89834206 0.81077822 831.00 2.19366261e-01 1.88971020e-01 2.89536876e-01 0.71109858 0.89741912 831.25 2.24441721e-01 1.63132054e-01 2.77463787e-01 0.62850980 0.90459339 831.50 2.16370585e-01 1.25175078e-01 2.49970059e-01 0.52447690 0.89667019 831.75 2.02706330e-01 1.12010222e-01 2.31594788e-01 0.50481717 0.88542829 832.00 2.01827636e-01 9.70271209e-02 2.23938958e-01 0.44812326 0.90963962 832.25 1.90465060e-01 8.15154930e-02 2.07175565e-01 0.40439316 0.91032509 832.50 1.89230532e-01 6.36552189e-02 1.99650147e-01 0.32449884 0.93869765 832.75 1.79218279e-01 6.83367311e-02 1.91804849e-01 0.36428639 0.92629957 833.00 1.75482484e-01 6.24204253e-02 1.86253622e-01 0.34175032 0.93873352 833.25 1.72141149e-01 5.48647411e-02 1.80672950e-01 0.30854096 0.92999505 833.50 1.64941902e-01 5.15784264e-02 1.72818300e-01 0.30307310 0.94900248 833.75 1.60372593e-01 5.59643993e-02 1.69856947e-01 0.33575235 0.92557267 834.00 1.51046500e-01 6.36082568e-02 1.63893427e-01 0.39857716 0.93952305 834.25 1.54799147e-01 7.08522297e-02 1.70243397e-01 0.42924229 0.94763794 834.50 1.58138439e-01 7.21732992e-02 1.73829661e-01 0.42815773 0.95849661 834.75 1.65417380e-01 7.28171602e-02 1.80735299e-01 0.41467660 0.95918390 835.00 1.70161823e-01 7.46347773e-02 1.85810108e-01 0.41334223 0.96509283 835.25 1.76121361e-01 7.14900895e-02 1.90077791e-01 0.38559406 0.95253581 835.50 1.78371795e-01 7.36102924e-02 1.92963655e-01 0.39138853 0.96425426 835.75 1.85882113e-01 6.44864801e-02 1.96750263e-01 0.33392955 0.95647486 836.00 1.87538753e-01 6.23135223e-02 1.97620240e-01 0.32079335 0.95966411 836.25 1.83975396e-01 6.02014249e-02 1.93574683e-01 0.31624339 0.95821184 836.50 1.81444216e-01 5.60695292e-02 1.89909967e-01 0.29970952 0.95862842 836.75 1.82950012e-01 5.72626299e-02 1.91702154e-01 0.30333672 0.94842151 837.00 1.85765539e-01 6.12331785e-02 1.95597387e-01 0.31841038 0.95405568 837.25 1.90847300e-01 6.77692600e-02 2.02522503e-01 0.34120814 0.93882616 837.50 2.02380994e-01 6.92928348e-02 2.13914852e-01 0.32987755 0.94961928 837.75 2.18660219e-01 6.67047046e-02 2.28608418e-01 0.29609342 0.95133777 838.00 2.27489518e-01 6.31729061e-02 2.36098067e-01 0.27087083 0.95094432 838.25 2.47779805e-01 5.74757165e-02 2.54358585e-01 0.22793185 0.96673858 838.50 2.48945879e-01 4.96720606e-02 2.53853036e-01 0.19694317 0.96364958 838.75 2.64422361e-01 2.73896689e-02 2.65837128e-01 0.10321493 0.93789013 839.00 2.68348940e-01 6.27322190e-03 2.68422255e-01 0.02337285 0.94694924 839.25 2.55371603e-01 -1.13564419e-02 2.55623990e-01 -0.04444098 0.93707271 839.50 2.56787843e-01 -1.56472115e-02 2.57264128e-01 -0.06085914 0.91851099 839.75 2.37035040e-01 -1.07905802e-02 2.37280523e-01 -0.04549174 0.91014849 840.00 2.28782329e-01 -1.03514127e-02 2.29016388e-01 -0.04521485 0.87813683 840.25 2.20002575e-01 -3.15709474e-02 2.22256288e-01 -0.14252957 0.81164913 840.50 2.16596697e-01 -1.93259939e-02 2.17457175e-01 -0.08899005 0.81457802 840.75 2.08570778e-01 1.48390297e-02 2.09097982e-01 0.07102658 0.85748722 841.00 2.07117738e-01 1.15455931e-02 2.07439288e-01 0.05568647 0.82932981 841.25 2.31409655e-01 3.02374716e-02 2.33376805e-01 0.12993029 0.88718697 841.50 2.47616659e-01 2.91067059e-02 2.49321500e-01 0.11701049 0.87513632 841.75 2.69799969e-01 1.48307466e-02 2.70207280e-01 0.05491415 0.82810414 842.00 3.16032514e-01 3.71724137e-04 3.16032732e-01 0.00117622 0.85556310 842.25 3.53684826e-01 -4.57792212e-03 3.53714452e-01 -0.01294278 0.92067047 842.50 3.66796172e-01 -1.53598514e-02 3.67117633e-01 -0.04185126 0.91989914 842.75 3.71488767e-01 -6.05618952e-02 3.76392943e-01 -0.16160320 0.90596442 843.00 3.87466440e-01 -1.16032309e-01 4.04467229e-01 -0.29096512 0.88519504 843.25 3.94839782e-01 -1.82077586e-01 4.34799610e-01 -0.43208168 0.89394050 843.50 3.60129388e-01 -2.17340917e-01 4.20630777e-01 -0.54299482 0.87061620 843.75 3.28695356e-01 -2.67767320e-01 4.23957515e-01 -0.68360229 0.83096209 844.00 2.98318347e-01 -3.10544703e-01 4.30617984e-01 -0.80547610 0.83996698 844.25 2.55080944e-01 -3.74502709e-01 4.53120919e-01 -0.97285482 0.90175643 844.50 2.10705545e-01 -3.88782821e-01 4.42209124e-01 -1.07414520 0.89119983 844.75 1.51258678e-01 -3.81754694e-01 4.10628584e-01 -1.19355319 0.89097300 845.00 8.50806074e-02 -3.79439016e-01 3.88860742e-01 -1.35021742 0.88215281 845.25 3.11145075e-02 -3.59761980e-01 3.61104964e-01 -1.48452463 0.87488890 845.50 6.59919658e-03 -3.25165696e-01 3.25232654e-01 -1.55050424 0.85823286 845.75 -1.16583506e-02 -3.07812922e-01 3.08033622e-01 -1.60865302 0.88864293 846.00 -5.64536155e-02 -2.36760198e-01 2.43397621e-01 -1.80486780 0.74807022 846.25 -9.09019948e-02 -2.14750232e-01 2.33196987e-01 -1.97121915 0.72092312 846.50 -6.46268409e-02 -2.02975947e-01 2.13016112e-01 -1.87904408 0.74350791 846.75 -5.27154982e-02 -1.87454912e-01 1.94726136e-01 -1.84493315 0.73617146 847.00 -4.89048006e-02 -1.34147627e-01 1.42783982e-01 -1.92038247 0.56548023 847.25 -5.14527238e-02 -1.05220303e-01 1.17126832e-01 -2.02560524 0.48859477 847.50 -4.98001290e-02 -8.61348669e-02 9.94950659e-02 -2.09500562 0.34741645 847.75 -3.77773811e-02 -7.57615277e-02 8.46577794e-02 -2.03335168 0.30655081 848.00 -3.84281477e-02 -4.79680736e-02 6.14626604e-02 -2.24621937 0.22334769 848.25 -3.53431942e-02 -4.18768348e-02 5.47979075e-02 -2.27178484 0.17644218 848.50 -9.13262657e-03 -1.31812057e-02 1.60358677e-02 -2.17670894 0.01544446 848.75 -3.72196541e-03 -1.29634853e-03 3.94126199e-03 -2.80643599 0.00123151 849.00 2.09537664e-02 9.32451143e-04 2.09745033e-02 0.04447107 0.02111989 849.25 2.80545315e-02 -5.01171917e-03 2.84986678e-02 -0.17677730 0.03787115 849.50 3.07397577e-02 2.28915933e-02 3.83269846e-02 0.64009410 0.04923761 849.75 4.89159494e-02 4.35995865e-02 6.55262851e-02 0.72799675 0.09993436 850.00 8.28959626e-02 6.92282570e-02 1.08001353e-01 0.69579306 0.24430772 850.25 9.11474624e-02 6.42155485e-02 1.11496621e-01 0.61375556 0.34783846 850.50 1.14621379e-01 5.20431755e-02 1.25883091e-01 0.42621202 0.51765032 850.75 1.43793032e-01 7.32619546e-02 1.61380761e-01 0.47121541 0.60093542 851.00 1.85965845e-01 6.66296355e-02 1.97541904e-01 0.34404063 0.67504327 851.25 2.25556524e-01 3.30738493e-02 2.27968474e-01 0.14559464 0.72167519 851.50 2.63479834e-01 8.88101343e-03 2.63629466e-01 0.03369386 0.78726246 851.75 2.90569607e-01 9.40154217e-03 2.90721664e-01 0.03234428 0.78292530 852.00 3.06764682e-01 -2.34549796e-02 3.07660049e-01 -0.07631072 0.78807945 852.25 3.18378512e-01 -5.11432661e-02 3.22460091e-01 -0.15927599 0.79544117 852.50 3.67646692e-01 -9.67077836e-02 3.80153239e-01 -0.25721854 0.82599048 852.75 3.94793323e-01 -1.51471219e-01 4.22853755e-01 -0.36635193 0.81679292 853.00 3.89022954e-01 -2.33868295e-01 4.53908844e-01 -0.54127815 0.84552687 853.25 4.18305155e-01 -2.93235234e-01 5.10848417e-01 -0.61140211 0.87454032 853.50 4.00795901e-01 -3.59610472e-01 5.38476598e-01 -0.73128864 0.86928075 853.75 3.69094633e-01 -4.59157390e-01 5.89114893e-01 -0.89371095 0.83498664 854.00 3.08795673e-01 -5.45262159e-01 6.26630345e-01 -1.05550587 0.84617021 854.25 1.66490113e-01 -6.07910950e-01 6.30297296e-01 -1.30347861 0.82390453 854.50 5.14972324e-02 -6.59422072e-01 6.61429841e-01 -1.49286001 0.87692741 854.75 -5.06398433e-02 -6.37966643e-01 6.39973305e-01 -1.65000719 0.81862697 855.00 -1.39367533e-01 -6.17242692e-01 6.32781045e-01 -1.79286305 0.86431134 855.25 -2.24046722e-01 -5.83137824e-01 6.24697251e-01 -1.93761598 0.78547293 855.50 -3.26401350e-01 -5.22856626e-01 6.16373988e-01 -2.12886728 0.81756483 855.75 -2.85325992e-01 -4.27520642e-01 5.13989126e-01 -2.15930437 0.77970771 856.00 -2.96165972e-01 -3.67821069e-01 4.72235770e-01 -2.24869411 0.76629565 856.25 -3.56129626e-01 -3.17232595e-01 4.76932731e-01 -2.41389576 0.76648589 856.50 -3.89858558e-01 -2.58669345e-01 4.67866996e-01 -2.55578878 0.75933275 856.75 -4.42487369e-01 -1.36386089e-01 4.63029413e-01 -2.84260631 0.73044359 857.00 -4.56440934e-01 -9.18532988e-02 4.65591403e-01 -2.94300691 0.74088517 857.25 -4.29511781e-01 -5.66026665e-02 4.33225383e-01 -3.01056396 0.71895301 857.50 -4.42062555e-01 -5.24467073e-03 4.42093665e-01 -3.12972912 0.73455043 857.75 -4.22072049e-01 5.05116231e-02 4.25083802e-01 3.02248377 0.75723446 858.00 -4.07110049e-01 6.66317565e-02 4.12526827e-01 2.97936093 0.72388366 858.25 -2.99054119e-01 1.95232948e-01 3.57140407e-01 2.56322715 0.66702547 858.50 -2.23993082e-01 2.36339127e-01 3.25621074e-01 2.32938106 0.68762983 858.75 -1.41337889e-01 2.19880443e-01 2.61388232e-01 2.14208932 0.66012385 859.00 -1.08172689e-01 1.61261295e-01 1.94181708e-01 2.16164908 0.55711764 859.25 -1.26625587e-01 1.05429840e-01 1.64771024e-01 2.44728090 0.55226440 859.50 -1.42013248e-01 1.04886535e-01 1.76547296e-01 2.50544783 0.61021103 859.75 -1.76727265e-01 1.07859160e-01 2.07041360e-01 2.59362368 0.66792136 860.00 -1.65264868e-01 1.13487199e-01 2.00478978e-01 2.53984951 0.61162840 860.25 -1.90386496e-01 1.48801091e-01 2.41637710e-01 2.47818864 0.75470273 860.50 -1.82641105e-01 1.59700542e-01 2.42614996e-01 2.42310519 0.75151933 860.75 -1.00774868e-01 1.61642989e-01 1.90483674e-01 2.12827379 0.64001790 861.00 -8.00440466e-02 1.44285999e-01 1.65001512e-01 2.07728641 0.60622829 861.25 -4.60566121e-02 1.29469105e-01 1.37417105e-01 1.91257057 0.55603052 861.50 -4.64284722e-02 1.12542195e-01 1.21742962e-01 1.96206848 0.48544355 861.75 -7.07039644e-02 8.72900138e-02 1.12332529e-01 2.25159861 0.47993995 862.00 -8.58113100e-02 7.62533678e-02 1.14796154e-01 2.41510235 0.47361685 862.25 -1.30242158e-01 7.44494330e-02 1.50019125e-01 2.62229987 0.77541521 862.50 -1.34002860e-01 8.21684232e-02 1.57189110e-01 2.59153532 0.76202555 862.75 -1.39676528e-01 9.95932439e-02 1.71546923e-01 2.52217662 0.73595391 863.00 -1.41530283e-01 1.29629947e-01 1.91923798e-01 2.40005308 0.79137980 863.25 -1.41716751e-01 1.63732518e-01 2.16545549e-01 2.28424224 0.84760280 863.50 -1.21528652e-01 1.70155113e-01 2.09098005e-01 2.19100411 0.77694563 863.75 -9.53721909e-02 1.84120890e-01 2.07355629e-01 2.04872962 0.86766521 864.00 -7.84630767e-02 1.81101247e-01 1.97367972e-01 1.97963846 0.84935385 864.25 -4.81964269e-02 1.97377020e-01 2.03176238e-01 1.81029422 0.86664672 864.50 -3.61157211e-02 1.85460399e-01 1.88944185e-01 1.76312477 0.82421920 864.75 -3.80505794e-02 1.68243632e-01 1.72492800e-01 1.79321799 0.82715528 865.00 -2.97497843e-02 1.50420210e-01 1.53333915e-01 1.76605428 0.76346307 865.25 -3.96038523e-02 1.50822721e-01 1.55935751e-01 1.82758460 0.77214720 865.50 -4.52311816e-02 1.45406050e-01 1.52278623e-01 1.87237614 0.77738086 865.75 -5.11556613e-02 1.38132688e-01 1.47300853e-01 1.92547273 0.77054339 866.00 -5.81286857e-02 1.29773146e-01 1.42197094e-01 1.99192366 0.73083040 866.25 -6.78847634e-02 1.37880311e-01 1.53685787e-01 2.02830168 0.82587306 866.50 -6.49853453e-02 1.55344893e-01 1.68389818e-01 1.96700343 0.82795829 866.75 -4.76168167e-02 1.63015347e-01 1.69827455e-01 1.85498994 0.79154557 867.00 -4.16745657e-02 1.64871684e-01 1.70057172e-01 1.81838006 0.79656438 867.25 -3.95863366e-02 1.70037230e-01 1.74584471e-01 1.79953172 0.85784722 867.50 -2.76232580e-02 1.55631201e-01 1.58063643e-01 1.74645870 0.80138391 867.75 -2.67889346e-02 1.44268743e-01 1.46734854e-01 1.75439298 0.78036730 868.00 -2.27763225e-02 1.35726013e-01 1.37623804e-01 1.73705824 0.74205336 868.25 -2.09132459e-02 1.29292707e-01 1.30973157e-01 1.73115858 0.71490048 868.50 -1.32887391e-02 9.39470712e-02 9.48822574e-02 1.71131334 0.55896334 868.75 -1.86032847e-02 9.08652809e-02 9.27501023e-02 1.77274040 0.59218596 869.00 -6.02455180e-02 8.75990610e-02 1.06316123e-01 2.17324771 0.55566846 869.25 -6.10950850e-02 8.39221247e-02 1.03805262e-01 2.20006640 0.56819910 869.50 -8.04329151e-02 9.65387091e-02 1.25654989e-01 2.26543673 0.61685428 869.75 -8.36498620e-02 9.61452822e-02 1.27441024e-01 2.28680796 0.63043653 870.00 -1.12288676e-01 1.00341031e-01 1.50589074e-01 2.41232538 0.67797059 870.25 -1.13650469e-01 1.13786298e-01 1.60822109e-01 2.35559727 0.67735360 870.50 -1.50332607e-01 1.53035014e-01 2.14521813e-01 2.34728670 0.72901071 870.75 -1.52520298e-01 1.55943342e-01 2.18130161e-01 2.34509787 0.69219867 871.00 -1.65225015e-01 1.52122176e-01 2.24589542e-01 2.39745971 0.81380639 871.25 -1.58206165e-01 1.41232877e-01 2.12075260e-01 2.41281752 0.78301219 871.50 -1.42788783e-01 1.48129283e-01 2.05744796e-01 2.33783915 0.72601181 871.75 -1.63671428e-01 1.49297827e-01 2.21535950e-01 2.40208880 0.72710894 872.00 -1.83479567e-01 1.36332717e-01 2.28585567e-01 2.50256064 0.74474959 872.25 -1.98100354e-01 1.31882128e-01 2.37984550e-01 2.55423607 0.74854143 872.50 -2.51066293e-01 1.39388111e-01 2.87164289e-01 2.63477775 0.85003964 872.75 -2.67662732e-01 1.46264013e-01 3.05018852e-01 2.64147988 0.83638845 873.00 -2.64939477e-01 1.62956242e-01 3.11042864e-01 2.59016613 0.78636071 873.25 -2.81443829e-01 2.00617074e-01 3.45626734e-01 2.52231843 0.78400524 873.50 -3.02697546e-01 2.48724085e-01 3.91777328e-01 2.45376426 0.81599009 873.75 -3.06624075e-01 2.64752659e-01 4.05107756e-01 2.42934536 0.80249800 874.00 -2.88176760e-01 3.54134196e-01 4.56570777e-01 2.25386546 0.81885957 874.25 -3.24227614e-01 4.20539083e-01 5.31014752e-01 2.22759057 0.82055849 874.50 -3.72989065e-01 3.96851794e-01 5.44621143e-01 2.32520745 0.82846812 874.75 -3.31547625e-01 4.08517150e-01 5.26127446e-01 2.25256330 0.74928337 875.00 -2.90309368e-01 4.56553569e-01 5.41036681e-01 2.13717513 0.81743151 875.25 -2.93047707e-01 4.64389152e-01 5.49121338e-01 2.13372657 0.81844745 875.50 -3.60511434e-01 4.45271626e-01 5.72918244e-01 2.25139007 0.80843818 875.75 -3.81783852e-01 4.06496532e-01 5.57672251e-01 2.32485464 0.80617568 876.00 -3.80689119e-01 4.10109517e-01 5.59565922e-01 2.31900824 0.83213103 876.25 -4.10204885e-01 4.28975558e-01 5.93538606e-01 2.33383036 0.81253866 876.50 -4.71895596e-01 4.74986502e-01 6.69550320e-01 2.35293020 0.82278975 876.75 -4.49565722e-01 5.25386628e-01 6.91477004e-01 2.27858187 0.79435033 877.00 -4.48246244e-01 5.44415633e-01 7.05204280e-01 2.25961559 0.77436311 877.25 -5.14390211e-01 5.63390990e-01 7.62893634e-01 2.31076128 0.76826127 877.50 -5.34337786e-01 5.27722633e-01 7.51004692e-01 2.36242301 0.73974684 877.75 -4.59844958e-01 5.64444392e-01 7.28048664e-01 2.25442823 0.62654668 878.00 -4.74980551e-01 6.61119694e-01 8.14055142e-01 2.19379693 0.65396714 878.25 -4.74935816e-01 5.91163764e-01 7.58313012e-01 2.24760171 0.48985029 878.50 -5.86828656e-01 5.53767327e-01 8.06861899e-01 2.38517239 0.48185604 878.75 -4.89597026e-01 6.07886209e-01 7.80532440e-01 2.24882675 0.40891292 879.00 -4.71987785e-01 4.98964864e-01 6.86832152e-01 2.32841750 0.32634974 879.25 -5.03873619e-01 2.44870502e-01 5.60223336e-01 2.68922703 0.16230437 879.50 -3.59621294e-01 7.96837570e-02 3.68343557e-01 2.92353878 0.07341340 879.75 -2.41002645e-01 -1.23627370e-01 2.70861591e-01 -2.66762216 0.03899705 880.00 -3.06226537e-01 -2.09822647e-01 3.71214540e-01 -2.54087718 0.07524589 880.25 -2.90489241e-01 -4.87954475e-01 5.67876367e-01 -2.10776782 0.24823671 880.50 -9.13384159e-02 -6.01289255e-01 6.08187039e-01 -1.72154814 0.35577460 880.75 4.23682138e-02 -4.85654239e-01 4.87498826e-01 -1.48377718 0.45993928 881.00 -5.37566611e-03 -4.08343613e-01 4.08378996e-01 -1.58396013 0.47509885 881.25 -4.94021332e-02 -3.65824568e-01 3.69145209e-01 -1.70502752 0.61140933 881.50 4.19233854e-03 -2.96976797e-01 2.97006386e-01 -1.55668054 0.54204388 881.75 9.70057782e-02 -1.76832068e-01 2.01692095e-01 -1.06904727 0.47824881 882.00 1.28305686e-01 -1.34841760e-01 1.86130732e-01 -0.81023113 0.42672047 882.25 1.46854324e-01 -5.57792409e-02 1.57090790e-01 -0.36299585 0.44442185 882.50 1.62362463e-01 -1.26496454e-02 1.62854484e-01 -0.07775285 0.48660322 882.75 1.87431640e-01 2.35710269e-02 1.88907948e-01 0.12510126 0.62397768 883.00 1.94763946e-01 4.82825292e-02 2.00659407e-01 0.24300386 0.57908000 883.25 2.21147741e-01 6.76530725e-02 2.31264484e-01 0.29687726 0.62625354 883.50 2.18931014e-01 9.71581164e-02 2.39521374e-01 0.41767282 0.59431878 883.75 1.97792049e-01 1.46768821e-01 2.46298155e-01 0.63838463 0.63415512 884.00 1.93475746e-01 2.05539923e-01 2.82275618e-01 0.81562380 0.60187762 884.25 1.52101003e-01 2.61993239e-01 3.02944174e-01 1.04479871 0.59119270 884.50 1.55169638e-01 2.44681575e-01 2.89735551e-01 1.00563024 0.50920757 884.75 1.93225323e-01 2.40288068e-01 3.08341338e-01 0.89353589 0.34017285 885.00 2.19870514e-01 1.95957305e-01 2.94520472e-01 0.72795396 0.24879916 885.25 2.08509670e-01 1.75925876e-01 2.72811650e-01 0.70084276 0.16577591 885.50 2.27699145e-01 1.53956788e-01 2.74862863e-01 0.59453329 0.17067682 885.75 2.85591876e-01 -1.51815488e-02 2.85995103e-01 -0.05310821 0.18253456 886.00 2.31193808e-01 -1.53794061e-02 2.31704775e-01 -0.06642384 0.17237484 886.25 1.83823532e-01 -1.04212396e-02 1.84118693e-01 -0.05663093 0.17010480 886.50 1.50590538e-01 5.95618892e-02 1.61941745e-01 0.37664019 0.17154254 886.75 1.42649375e-01 1.90182631e-01 2.37735730e-01 0.92725348 0.36228661 887.00 2.67139703e-01 2.59825856e-01 3.72656808e-01 0.77151988 0.49866520 887.25 3.51240975e-01 3.50365119e-01 4.96110813e-01 0.78414980 0.59495335 887.50 5.03902565e-01 2.69981890e-01 5.71671248e-01 0.49186174 0.60747951 887.75 5.23691060e-01 1.64048433e-01 5.48784306e-01 0.30357184 0.55304028 888.00 3.51638244e-01 8.03666664e-02 3.60705220e-01 0.22469012 0.41487251 888.25 2.87091416e-01 7.66570193e-02 2.97149424e-01 0.26092531 0.33319178 888.50 1.97628880e-01 6.28497649e-02 2.07381935e-01 0.30790504 0.22436197 888.75 1.36089473e-01 -2.15655841e-02 1.37787587e-01 -0.15715941 0.10786559 889.00 9.20067887e-02 -2.13033790e-02 9.44408975e-02 -0.22753183 0.07673722 889.25 5.64569688e-02 -1.29693748e-02 5.79274892e-02 -0.22580378 0.02864337 889.50 -2.78357956e-02 -7.21197352e-02 7.73051598e-02 -1.93914656 0.04282027 889.75 -3.86755548e-02 -9.32315026e-02 1.00935185e-01 -1.96402448 0.09467279 890.00 -1.17302610e-01 -8.08286603e-02 1.42454114e-01 -2.53824605 0.21462171 890.25 -1.21780602e-01 -1.08628378e-01 1.63188969e-01 -2.41321469 0.27610689 890.50 -2.14963404e-01 -2.12044679e-01 3.01947364e-01 -2.36302967 0.50540167 890.75 -1.95663331e-01 -2.83949330e-01 3.44835266e-01 -2.17415464 0.57605837 891.00 -1.30885060e-01 -3.71790485e-01 3.94156141e-01 -1.90928721 0.61628456 891.25 -1.52178438e-01 -3.82259277e-01 4.11437033e-01 -1.94966600 0.58135145 891.50 -1.40487129e-01 -3.35673487e-01 3.63886415e-01 -1.96716827 0.43306100 891.75 -9.01803307e-02 -3.45889619e-01 3.57452263e-01 -1.82583865 0.36598742 892.00 -5.38197111e-02 -3.33611357e-01 3.37924694e-01 -1.73074284 0.43407531 892.25 5.80935998e-02 -2.80108057e-01 2.86068855e-01 -1.36629839 0.32969189 892.50 1.55549734e-01 -2.27452049e-01 2.75554267e-01 -0.97097180 0.36451226 892.75 2.26454373e-01 -2.40334640e-01 3.30215569e-01 -0.81512504 0.41007484 893.00 4.75661000e-01 -3.44073501e-01 5.87060441e-01 -0.62623150 0.70158888 893.25 5.86755132e-01 -4.06227224e-01 7.13654078e-01 -0.60555864 0.74482869 893.50 7.36734674e-01 -3.81858249e-01 8.29815462e-01 -0.47818947 0.81819333 893.75 8.12338283e-01 -3.91141183e-01 9.01601303e-01 -0.44873868 0.82615752 894.00 9.12554333e-01 -4.25847593e-01 1.00702611e+00 -0.43661718 0.80870767 894.25 9.90634157e-01 -4.46157665e-01 1.08646799e+00 -0.42316641 0.82571497 894.50 1.02791902e+00 -4.38796864e-01 1.11765835e+00 -0.40346095 0.83150421 894.75 9.60975688e-01 -4.91336955e-01 1.07929897e+00 -0.47263851 0.71622180 895.00 9.95934381e-01 -5.97594545e-01 1.16146654e+00 -0.54044454 0.72074383 895.25 1.01863999e+00 -7.01601571e-01 1.23688003e+00 -0.60314450 0.65290951 895.50 1.17655777e+00 -8.35069444e-01 1.44278521e+00 -0.61724394 0.71608575 895.75 1.31545515e+00 -8.44980148e-01 1.56346209e+00 -0.57097722 0.75378221 896.00 1.44221805e+00 -7.86253000e-01 1.64261580e+00 -0.49912685 0.72667951 896.25 1.62297440e+00 -8.33027442e-01 1.82427537e+00 -0.47420881 0.83403532 896.50 1.65071306e+00 -8.57721558e-01 1.86025264e+00 -0.47920965 0.87557488 896.75 1.44205114e+00 -1.02680334e+00 1.77026456e+00 -0.61876329 0.79951253 897.00 1.40040432e+00 -1.12445820e+00 1.79597843e+00 -0.67653868 0.78376221 897.25 1.31248819e+00 -1.20048625e+00 1.77870529e+00 -0.74085817 0.72195614 897.50 1.24973698e+00 -1.24213520e+00 1.76202792e+00 -0.78234754 0.64382143 897.75 1.22839088e+00 -1.10777978e+00 1.65412218e+00 -0.73381627 0.53289381 898.00 1.09637297e+00 -1.18267642e+00 1.61268633e+00 -0.82324826 0.45376560 898.25 5.95752868e-01 -1.40741959e+00 1.52831651e+00 -1.17037120 0.35157367 898.50 -1.37861515e-02 -1.55452361e+00 1.55458474e+00 -1.57966450 0.37346833 898.75 -3.27129638e-01 -1.58092115e+00 1.61441180e+00 -1.77484009 0.31050562 899.00 -5.71838820e-01 -1.26809767e+00 1.39106842e+00 -1.99443355 0.26682980 899.25 -1.14587802e+00 -1.01036093e+00 1.52769946e+00 -2.41896076 0.33363875 899.50 -1.27290991e+00 -1.18191200e+00 1.73701342e+00 -2.39324657 0.39722396 899.75 -1.29924168e+00 -7.70439533e-01 1.51049860e+00 -2.60634225 0.38806007 900.00 -1.37694113e+00 -5.95185600e-01 1.50007092e+00 -2.73359554 0.43499299 900.25 -1.68539361e+00 -2.46012968e-01 1.70325394e+00 -2.99664862 0.50545456 900.50 -1.59108704e+00 -9.91766038e-02 1.59417502e+00 -3.07934059 0.37998242 900.75 -1.31361763e+00 3.55753360e-01 1.36093781e+00 2.87711709 0.31348251 901.00 -1.18879551e+00 3.49895740e-01 1.23921822e+00 2.85534767 0.33059431 901.25 -8.42196832e-01 4.63932562e-01 9.61524272e-01 2.63808940 0.16637421 901.50 -8.38596839e-01 5.33525532e-01 9.93928645e-01 2.57497124 0.20071105 901.75 -2.84086317e-01 8.52700275e-01 8.98778502e-01 1.89239161 0.27865629 902.00 -1.54198765e-01 9.10139172e-01 9.23109187e-01 1.73862591 0.31949441 902.25 -3.70098262e-01 8.18348249e-01 8.98146191e-01 1.99552005 0.27560087 902.50 -2.90704780e-01 9.76926446e-01 1.01926177e+00 1.86002301 0.41707990 902.75 5.64345204e-02 1.09088514e+00 1.09234392e+00 1.51910962 0.58299206 903.00 1.98142788e-01 1.13734467e+00 1.15447541e+00 1.39831219 0.66135247 903.25 1.80436339e-01 1.00707393e+00 1.02311054e+00 1.39350851 0.65206560 903.50 2.96276161e-01 8.87717041e-01 9.35853144e-01 1.24867021 0.58509782 903.75 4.37359735e-01 9.35880023e-01 1.03303192e+00 1.13362905 0.75721090 904.00 3.88770923e-01 8.93867404e-01 9.74752157e-01 1.16054393 0.78491444 904.25 4.24922308e-01 7.84637296e-01 8.92308610e-01 1.07446183 0.74100888 904.50 3.80308294e-01 7.81342976e-01 8.68982879e-01 1.11781555 0.78198759 904.75 4.04497359e-01 8.15387663e-01 9.10206106e-01 1.11028978 0.87680137 905.00 5.15225545e-01 8.05043915e-01 9.55799700e-01 1.00148539 0.89032284 905.25 6.50137697e-01 7.83348429e-01 1.01799498e+00 0.87805986 0.90665365 905.50 6.89883934e-01 7.26690539e-01 1.00200748e+00 0.81137514 0.90571947 905.75 7.35712694e-01 6.44230093e-01 9.77908779e-01 0.71920054 0.91407639 906.00 7.12051098e-01 5.21386450e-01 8.82530791e-01 0.63203214 0.90765836 906.25 6.72733537e-01 4.43195527e-01 8.05600824e-01 0.58253528 0.91615472 906.50 6.64777294e-01 4.19042738e-01 7.85828013e-01 0.56243766 0.93207592 906.75 6.52588997e-01 3.81530956e-01 7.55935361e-01 0.52905033 0.91115712 907.00 6.50360478e-01 3.22889834e-01 7.26103709e-01 0.46082624 0.88801727 907.25 6.33324832e-01 2.24706579e-01 6.72006986e-01 0.34094868 0.87597588 907.50 5.93673630e-01 1.65417952e-01 6.16288470e-01 0.27174202 0.87533339 907.75 5.67428176e-01 1.71342164e-01 5.92733391e-01 0.29325650 0.89659450 908.00 5.21908470e-01 1.32735646e-01 5.38523169e-01 0.24904738 0.88647244 908.25 4.85057109e-01 1.45394494e-01 5.06379263e-01 0.29122482 0.91347101 908.50 4.66637788e-01 1.45333070e-01 4.88745871e-01 0.30192552 0.90801416 908.75 4.34313060e-01 1.47953224e-01 4.58822395e-01 0.32833028 0.91010534 909.00 4.09396441e-01 1.45323397e-01 4.34424142e-01 0.34109543 0.87113270 909.25 3.85546016e-01 1.63826980e-01 4.18909310e-01 0.40180457 0.85127537 909.50 4.07382833e-01 1.96092224e-01 4.52120485e-01 0.44861361 0.90729393 909.75 4.08717681e-01 2.01636823e-01 4.55749439e-01 0.45830551 0.91782510 910.00 4.14225833e-01 2.00650591e-01 4.60264815e-01 0.45108912 0.91228196 910.25 4.38340121e-01 2.06999749e-01 4.84758660e-01 0.44119030 0.90557359 910.50 3.79594830e-01 2.33520102e-01 4.45672382e-01 0.55150838 0.84565031 910.75 3.49080411e-01 2.42436790e-01 4.25009094e-01 0.60702600 0.82545057 911.00 3.56181639e-01 2.83990766e-01 4.55539368e-01 0.67310469 0.75088212 911.25 3.11815842e-01 2.99200846e-01 4.32146116e-01 0.76475519 0.71952644 911.50 3.03869359e-01 3.42858416e-01 4.58135876e-01 0.84561194 0.64932428 911.75 3.33144304e-01 3.92368137e-01 5.14721170e-01 0.86684792 0.56738887 912.00 4.54253885e-01 4.93265559e-01 6.70565063e-01 0.82654735 0.50410357 912.25 4.70507926e-01 5.47916075e-01 7.22211696e-01 0.86126008 0.47134709 912.50 7.30322105e-01 7.66086889e-01 1.05842312e+00 0.80929402 0.51689592 912.75 8.27368914e-01 6.73840663e-01 1.06705228e+00 0.68348279 0.45314936 913.00 7.65825755e-01 1.92822286e-01 7.89727498e-01 0.24665654 0.29334970 913.25 8.13807327e-01 1.39616888e-02 8.13927082e-01 0.01715433 0.24515896 913.50 8.19710757e-01 -6.90800955e-01 1.07197560e+00 -0.70026264 0.46794441 913.75 7.47332492e-01 -7.42004213e-01 1.05312682e+00 -0.78182056 0.46355632 914.00 3.85605650e-01 -7.99945464e-01 8.88034044e-01 -1.12161974 0.38653660 914.25 2.82727293e-01 -9.08957839e-01 9.51913377e-01 -1.26923705 0.45356467 914.50 4.03237713e-01 -1.02020366e+00 1.09700326e+00 -1.19438959 0.69282186 914.75 2.47351707e-01 -1.10548024e+00 1.13281482e+00 -1.35067154 0.73799496 915.00 4.89292722e-02 -1.06741036e+00 1.06853122e+00 -1.52498916 0.76326451 915.25 -6.03733638e-02 -1.04158480e+00 1.04333304e+00 -1.62869453 0.71089931 915.50 -1.99504785e-01 -1.00384379e+00 1.02347668e+00 -1.76698089 0.76208674 915.75 -1.57948688e-01 -8.54638272e-01 8.69111249e-01 -1.75354776 0.69145767 916.00 -2.91504453e-01 -8.24470849e-01 8.74486722e-01 -1.91064401 0.71073732 916.25 -5.24927915e-01 -8.50916604e-01 9.99804172e-01 -2.12354755 0.73760645 916.50 -7.03199309e-01 -7.38136668e-01 1.01947781e+00 -2.33195967 0.73532774 916.75 -9.14693286e-01 -5.04658888e-01 1.04467430e+00 -2.63742625 0.73980186 917.00 -1.03873256e+00 -2.47174498e-01 1.06773619e+00 -2.90797956 0.76938808 917.25 -9.92860013e-01 4.01451378e-02 9.93671293e-01 3.10118083 0.63983304 917.50 -9.46535057e-01 3.32887580e-01 1.00336571e+00 2.80341243 0.60276655 917.75 -5.99454946e-01 5.19613040e-01 7.93312009e-01 2.42742059 0.49160179 918.00 -2.71027957e-01 7.39664517e-01 7.87756150e-01 1.92202377 0.56056289 918.25 -6.95598609e-02 7.96773285e-01 7.99803878e-01 1.65787749 0.55062831 918.50 9.80914534e-02 7.21880693e-01 7.28514700e-01 1.43574032 0.53967755 918.75 2.44310503e-01 5.25400079e-01 5.79424598e-01 1.13553949 0.44995980 919.00 3.22641306e-01 4.45561958e-01 5.50111690e-01 0.94406374 0.49804220 919.25 2.39702459e-01 2.98888492e-01 3.83133919e-01 0.89484951 0.31404152 919.50 2.77135518e-01 3.19531824e-01 4.22971254e-01 0.85633412 0.34512908 919.75 4.92845253e-01 2.64527377e-01 5.59348887e-01 0.49260207 0.42741768 920.00 5.78878625e-01 2.06790970e-01 6.14705594e-01 0.34309840 0.54562340 920.25 4.60711944e-01 1.36982616e-01 4.80645121e-01 0.28900373 0.49464782 920.50 4.32168761e-01 1.38859487e-01 4.53929284e-01 0.31088943 0.46365288 920.75 4.27241276e-01 -1.25053412e-02 4.27424252e-01 -0.02926162 0.48397625 921.00 4.83146244e-01 -1.07618610e-02 4.83266087e-01 -0.02227086 0.59265190 921.25 3.49868144e-01 5.36272508e-02 3.53954235e-01 0.15209471 0.42313408 921.50 3.61085118e-01 2.36963816e-02 3.61861826e-01 0.06553151 0.44146980 921.75 3.34734278e-01 -1.04205353e-01 3.50579224e-01 -0.30179826 0.44786271 922.00 3.54150589e-01 -9.16115695e-02 3.65807763e-01 -0.25313097 0.47390430 922.25 4.76833667e-01 -1.70632876e-02 4.77138871e-01 -0.03576931 0.65215151 922.50 4.59094527e-01 -1.15621812e-01 4.73430235e-01 -0.24671674 0.60821938 922.75 4.27408822e-01 -2.31149417e-01 4.85909821e-01 -0.49576462 0.64734683 923.00 3.87066918e-01 -2.23631435e-01 4.47025522e-01 -0.52390535 0.60547320 923.25 2.90468498e-01 -1.44289465e-01 3.24332234e-01 -0.46104213 0.39760025 923.50 2.67393780e-01 -1.95288989e-01 3.31115120e-01 -0.63080102 0.42287707 923.75 3.18834907e-01 -2.42047290e-01 4.00303121e-01 -0.64933894 0.69251887 924.00 3.45437424e-01 -2.30304581e-01 4.15171306e-01 -0.58802859 0.71582015 924.25 3.59565642e-01 -2.56352350e-01 4.41592548e-01 -0.61936451 0.72080564 924.50 3.86067981e-01 -2.69240983e-01 4.70679502e-01 -0.60897394 0.71797267 924.75 3.79737777e-01 -2.38785954e-01 4.48574978e-01 -0.56134014 0.65186928 925.00 4.47388121e-01 -2.36734658e-01 5.06161465e-01 -0.48669341 0.62985491 925.25 5.13705517e-01 -2.67716559e-01 5.79280169e-01 -0.48042245 0.69582977 925.50 4.36740866e-01 -4.09855714e-01 5.98935965e-01 -0.75365209 0.74175196 925.75 3.88565069e-01 -5.24341412e-01 6.52622961e-01 -0.93304557 0.88066484 926.00 3.92028019e-01 -5.48709531e-01 6.74364973e-01 -0.95043506 0.89228313 926.25 3.76746311e-01 -5.61004384e-01 6.75768971e-01 -0.97941588 0.90328940 926.50 3.65110936e-01 -5.73032213e-01 6.79464431e-01 -1.00350331 0.85488835 926.75 3.58575316e-01 -6.02804187e-01 7.01390864e-01 -1.03417557 0.84911221 927.00 3.41011001e-01 -6.65548027e-01 7.47825300e-01 -1.09729681 0.81696507 927.25 4.31523509e-01 -6.78354318e-01 8.03975820e-01 -1.00423135 0.81419459 927.50 4.43783991e-01 -7.23616628e-01 8.48861152e-01 -1.02066490 0.76984719 927.75 4.57528082e-01 -8.81812416e-01 9.93441031e-01 -1.09218295 0.79111376 928.00 5.45832340e-01 -1.07752490e+00 1.20788776e+00 -1.10191352 0.77002176 928.25 6.33525552e-01 -1.25223041e+00 1.40336582e+00 -1.10242576 0.81404105 928.50 4.51555564e-01 -1.38279302e+00 1.45465425e+00 -1.25516020 0.78844941 928.75 3.84815727e-01 -1.67301058e+00 1.71669670e+00 -1.34471472 0.79861121 929.00 2.73472253e-02 -1.99457980e+00 1.99476727e+00 -1.55708642 0.78807964 929.25 -1.96731352e-01 -2.10638367e+00 2.11555084e+00 -1.66392385 0.76339581 929.50 -1.29135850e-01 -2.18843374e+00 2.19224047e+00 -1.62973632 0.73404202 929.75 -2.62634979e-01 -2.43250185e+00 2.44663900e+00 -1.67834877 0.71092391 930.00 -9.74331316e-01 -2.68965070e+00 2.86068915e+00 -1.91834409 0.75470911 930.25 -1.27611466e+00 -3.01480512e+00 3.27376214e+00 -1.97121145 0.81604827 930.50 -1.56280881e+00 -3.10668433e+00 3.47762260e+00 -2.03687871 0.84311062 930.75 -1.71872753e+00 -3.11622738e+00 3.55877751e+00 -2.07482197 0.80836415 931.00 -2.06679362e+00 -2.86263826e+00 3.53076956e+00 -2.19612814 0.67197678 931.25 -2.48696351e+00 -3.27485503e+00 4.11213606e+00 -2.22029382 0.67095135 931.50 -2.71231317e+00 -3.91318382e+00 4.76126563e+00 -2.17689114 0.68613415 931.75 -3.08460238e+00 -2.95751998e+00 4.27337060e+00 -2.37722413 0.50896255 932.00 -3.95396207e+00 -9.99158841e-01 4.07825140e+00 -2.89407619 0.34971506 932.25 -3.81625007e+00 -1.28272590e+00 4.02605891e+00 -2.81733433 0.27242402 932.50 -4.00903823e+00 1.01045208e+00 4.13441663e+00 2.89469161 0.24614886 932.75 -3.99163102e+00 1.85430404e+00 4.40131363e+00 2.70670672 0.26900113 933.00 -3.03290847e+00 3.62009613e+00 4.72267189e+00 2.26816358 0.21664453 933.25 -2.79262946e+00 4.61800397e+00 5.39673420e+00 2.11468396 0.25844511 933.50 -7.88653135e-01 4.43784708e+00 4.50737844e+00 1.74667098 0.21226794 933.75 3.41126710e-02 4.02973582e+00 4.02988020e+00 1.56233129 0.22865604 934.00 1.78665289e+00 4.34896059e+00 4.70165788e+00 1.18099477 0.37253960 934.25 1.63183392e+00 3.88476412e+00 4.21358211e+00 1.17311735 0.40747229 934.50 1.35775658e+00 3.78542088e+00 4.02155619e+00 1.22640937 0.55565309 934.75 2.10658644e+00 3.75351124e+00 4.30424826e+00 1.05937146 0.51121708 935.00 2.44752713e+00 2.73237080e+00 3.66827469e+00 0.84033304 0.45155736 935.25 2.08052282e+00 2.44270263e+00 3.20864011e+00 0.86529883 0.44294131 935.50 2.31078418e+00 2.97421083e+00 3.76638468e+00 0.91027520 0.62215712 935.75 2.54728875e+00 2.73206067e+00 3.73534945e+00 0.82038288 0.55904235 936.00 2.88258213e+00 2.88677192e+00 4.07955045e+00 0.78612438 0.64817304 936.25 2.58924743e+00 2.78189842e+00 3.80041591e+00 0.82125056 0.67373127 936.50 2.56519407e+00 2.37313998e+00 3.49456921e+00 0.74652729 0.71181646 936.75 2.51725343e+00 2.26492442e+00 3.38621433e+00 0.73268259 0.75133059 937.00 2.38514632e+00 2.31959349e+00 3.32707633e+00 0.77146570 0.78492552 937.25 2.17629928e+00 2.15519786e+00 3.06286735e+00 0.78052658 0.79815655 937.50 2.16909710e+00 2.17137535e+00 3.06917793e+00 0.78592305 0.82354660 937.75 2.21304838e+00 1.96533257e+00 2.95974919e+00 0.72618236 0.80488509 938.00 2.25812123e+00 1.74828215e+00 2.85580145e+00 0.65882244 0.82127773 938.25 2.34885627e+00 1.74587845e+00 2.92663925e+00 0.63919206 0.87562680 938.50 2.41947527e+00 1.80131687e+00 3.01638907e+00 0.63997647 0.87433336 938.75 2.23085875e+00 1.79160372e+00 2.86121908e+00 0.67662862 0.82311391 939.00 2.05710746e+00 1.85436061e+00 2.76953866e+00 0.73361056 0.79130578 939.25 2.13999497e+00 1.39071247e+00 2.55218722e+00 0.57628184 0.76807247 939.50 2.24502969e+00 1.34633262e+00 2.61777956e+00 0.54019506 0.78377490 939.75 2.26223775e+00 1.38196041e+00 2.65094968e+00 0.54838260 0.79020519 940.00 2.24249947e+00 1.45031766e+00 2.67062262e+00 0.57408118 0.72964214 940.25 2.13605841e+00 1.46331715e+00 2.58921660e+00 0.60062508 0.70457958 940.50 2.20109505e+00 1.28948179e+00 2.55099642e+00 0.52994005 0.74996989 940.75 2.38578780e+00 1.39032016e+00 2.76133547e+00 0.52763983 0.67233485 941.00 2.45307661e+00 1.57844052e+00 2.91702920e+00 0.57175927 0.73282952 941.25 2.66214655e+00 1.36603048e+00 2.99216703e+00 0.47409731 0.81329910 941.50 2.51345409e+00 1.31964934e+00 2.83882473e+00 0.48347381 0.79044267 941.75 2.54245709e+00 1.23886172e+00 2.82822673e+00 0.45341141 0.76277212 942.00 2.80806010e+00 1.17134775e+00 3.04257409e+00 0.39519241 0.76448981 942.25 2.95044953e+00 1.01032737e+00 3.11863974e+00 0.32991659 0.71069725 942.50 2.91864195e+00 5.47510791e-01 2.96955197e+00 0.18543580 0.67338895 942.75 3.40723171e+00 -2.21854157e-01 3.41444683e+00 -0.06502094 0.65231418 943.00 3.55475693e+00 -3.66698411e-01 3.57362065e+00 -0.10279351 0.71760350 943.25 3.30931244e+00 -5.33901679e-01 3.35210379e+00 -0.15995483 0.72610298 943.50 3.31217694e+00 -5.29057382e-01 3.35416425e+00 -0.15839298 0.72835733 943.75 3.08433465e+00 -1.04177316e+00 3.25552016e+00 -0.32573166 0.73662143 944.00 2.94048019e+00 -1.33636737e+00 3.22990735e+00 -0.42656703 0.71091074 944.25 2.89912943e+00 -1.39974892e+00 3.21935529e+00 -0.44980694 0.73661772 944.50 2.71615115e+00 -1.48293573e+00 3.09460425e+00 -0.49974352 0.73852731 944.75 2.67753130e+00 -1.61895078e+00 3.12892561e+00 -0.54382654 0.73253759 945.00 2.49691912e+00 -1.74281117e+00 3.04499522e+00 -0.60937209 0.72636244 945.25 1.78972468e+00 -1.87646312e+00 2.59311169e+00 -0.80905278 0.69749143 945.50 2.01765834e+00 -1.91044715e+00 2.77862439e+00 -0.75811158 0.79797822 945.75 1.98842418e+00 -1.87893265e+00 2.73573000e+00 -0.75709400 0.75795477 946.00 1.74621705e+00 -2.05185401e+00 2.69432345e+00 -0.86569676 0.75405449 946.25 1.70779777e+00 -2.40942376e+00 2.95328564e+00 -0.95418920 0.81170185 946.50 1.41137466e+00 -2.31546526e+00 2.71170754e+00 -1.02338976 0.76665298 946.75 1.33471389e+00 -2.04941746e+00 2.44572547e+00 -0.99353233 0.68183931 947.00 1.18565559e+00 -2.41357170e+00 2.68907187e+00 -1.11417703 0.81335522 947.25 9.54456238e-01 -2.51174048e+00 2.68697356e+00 -1.20765111 0.85729989 947.50 8.37086019e-01 -2.41145940e+00 2.55261620e+00 -1.23668202 0.79630164 947.75 5.21061404e-01 -2.41456968e+00 2.47015216e+00 -1.35825672 0.79054825 948.00 2.69038569e-01 -2.46007531e+00 2.47474288e+00 -1.46186729 0.76244687 948.25 -6.61664392e-02 -2.49303439e+00 2.49391228e+00 -1.59733062 0.72642581 948.50 -9.82615035e-03 -2.38987209e+00 2.38989229e+00 -1.57490788 0.71593066 948.75 -1.20751182e-01 -2.27310279e+00 2.27630778e+00 -1.62386819 0.75022293 949.00 -2.55687408e-01 -2.12585040e+00 2.14117164e+00 -1.69049669 0.78796112 949.25 -1.65509420e-01 -1.99867062e+00 2.00551181e+00 -1.65341757 0.71223498 949.50 -4.24961843e-01 -1.71689027e+00 1.76870144e+00 -1.81343796 0.57012190 949.75 -5.98725649e-01 -1.49871977e+00 1.61388765e+00 -1.95086417 0.53609461 950.00 -3.87300631e-01 -1.15794519e+00 1.22099912e+00 -1.89357163 0.41233201 950.25 -4.68888883e-01 -1.04690840e+00 1.14711551e+00 -1.99188550 0.48079140 950.50 -4.72314044e-01 -9.98885148e-01 1.10492176e+00 -2.01248180 0.50060902 950.75 -4.23007334e-01 -9.49874796e-01 1.03980639e+00 -1.98975954 0.51939403 951.00 -1.63362999e-01 -6.64438060e-01 6.84226136e-01 -1.81188078 0.28313504 951.25 -8.19212194e-03 -5.78439129e-01 5.78497137e-01 -1.58495784 0.18796618 951.50 -1.29056984e-01 -7.90449820e-01 8.00916115e-01 -1.73263863 0.36033931 951.75 -1.49018976e-01 -7.13408898e-01 7.28806498e-01 -1.77671844 0.31597612 952.00 -1.49243120e-01 -7.22661670e-01 7.37911512e-01 -1.77445190 0.29913257 952.25 -2.29318504e-01 -8.58040321e-01 8.88155487e-01 -1.83195111 0.39721464 952.50 -2.67296498e-01 -9.50680480e-01 9.87542805e-01 -1.84488347 0.41987122 952.75 -2.61983574e-01 -9.69183736e-01 1.00396838e+00 -1.83480046 0.51365115 953.00 -2.08019097e-01 -8.47844557e-01 8.72990456e-01 -1.81139424 0.51537098 953.25 -1.55111305e-01 -8.93410269e-01 9.06775289e-01 -1.74269988 0.45372399 953.50 -1.30223754e-01 -9.92225490e-01 1.00073456e+00 -1.70129457 0.45234165 953.75 -1.06221373e-01 -1.07560689e+00 1.08083910e+00 -1.66923198 0.42310443 954.00 -5.25983032e-01 -1.20313935e+00 1.31308889e+00 -1.98293436 0.43424878 954.25 -4.82803916e-01 -1.24422381e+00 1.33461324e+00 -1.94094675 0.45107400 954.50 -6.56818536e-01 -9.53666656e-01 1.15796834e+00 -2.17391821 0.52398149 954.75 -8.25082408e-01 -8.67247129e-01 1.19702906e+00 -2.33128445 0.56332458 955.00 -9.60174797e-01 -8.70972894e-01 1.29635235e+00 -2.40486967 0.61628910 955.25 -9.98656711e-01 -6.89844503e-01 1.21375478e+00 -2.53708659 0.60697947 955.50 -9.70497618e-01 -4.42187714e-01 1.06648751e+00 -2.71406679 0.55469291 955.75 -1.04595267e+00 -2.77730874e-01 1.08219750e+00 -2.88205260 0.56409520 956.00 -1.17173107e+00 -3.06556151e-02 1.17213202e+00 -3.11543595 0.64937643 956.25 -1.15550910e+00 1.29724812e-01 1.16276816e+00 3.02979441 0.61154060 956.50 -1.06567370e+00 3.87578249e-01 1.13396531e+00 2.79277148 0.60417393 956.75 -9.10062177e-01 4.46453473e-01 1.01367345e+00 2.68551368 0.56624302 957.00 -7.09157972e-01 5.80741253e-01 9.16605385e-01 2.45542314 0.47155301 957.25 -5.13921952e-01 4.38239075e-01 6.75403035e-01 2.43551310 0.32732165 957.50 -3.06928246e-01 3.51973596e-01 4.67001457e-01 2.28793642 0.21191282 957.75 -2.50800292e-01 4.29772596e-01 4.97599508e-01 2.09904369 0.21191697 958.00 -1.85692183e-01 4.66548764e-01 5.02144737e-01 1.94958806 0.19656485 958.25 -1.74596815e-01 4.57368060e-01 4.89560609e-01 1.93546506 0.19861249 958.50 -1.93382547e-01 6.97508774e-01 7.23819936e-01 1.84125080 0.36597681 958.75 -4.06765833e-02 8.50205259e-01 8.51177753e-01 1.61860312 0.53194065 959.00 1.10296976e-01 9.55341325e-01 9.61687304e-01 1.45585228 0.63553168 959.25 4.29791708e-01 7.85005359e-01 8.94960517e-01 1.06987328 0.59756798 959.50 7.02819244e-01 6.36999673e-01 9.48537544e-01 0.73631190 0.62155192 959.75 1.02378345e+00 5.10974704e-01 1.14421488e+00 0.46293078 0.75849927 960.00 1.14826699e+00 4.94753858e-01 1.25031934e+00 0.40683211 0.83137364 960.25 1.02113772e+00 1.12562890e-01 1.02732305e+00 0.10978956 0.74031598 960.50 9.40430617e-01 -9.20565615e-02 9.44925477e-01 -0.09757680 0.78033924 960.75 1.05941826e+00 -2.63423638e-01 1.09167718e+00 -0.24370704 0.82749650 961.00 1.13702611e+00 -3.52564290e-01 1.19043267e+00 -0.30067483 0.86111594 961.25 9.74947188e-01 -6.33145423e-01 1.16249522e+00 -0.57596393 0.81109233 961.50 8.49250820e-01 -7.61507349e-01 1.14066665e+00 -0.73097855 0.83696474 961.75 6.94559727e-01 -8.00728995e-01 1.05999063e+00 -0.85628173 0.75387147 962.00 6.13833956e-01 -8.95397837e-01 1.08560095e+00 -0.96983891 0.79777481 962.25 5.94039352e-01 -9.53184681e-01 1.12314015e+00 -1.01348136 0.83937573 962.50 5.25670738e-01 -9.57727521e-01 1.09250708e+00 -1.06881882 0.83995812 962.75 4.46225146e-01 -9.84823544e-01 1.08120039e+00 -1.14536608 0.77032999 963.00 4.28099771e-01 -9.56004158e-01 1.04747953e+00 -1.14977246 0.73589170 963.25 5.12359841e-01 -1.03229119e+00 1.15244857e+00 -1.11008689 0.77214621 963.50 4.69825279e-01 -1.17167990e+00 1.26236666e+00 -1.18944168 0.78753100 963.75 2.74347467e-01 -1.19597009e+00 1.22703341e+00 -1.34530428 0.70036275 964.00 2.30438115e-01 -1.23798008e+00 1.25924437e+00 -1.38676212 0.71008824 964.25 3.50692171e-02 -1.28466606e+00 1.28514464e+00 -1.54350479 0.71372844 964.50 -9.21741781e-02 -1.19097212e+00 1.19453366e+00 -1.64803642 0.64275725 964.75 -1.40481753e-01 -1.21713280e+00 1.22521320e+00 -1.68570808 0.66486931 965.00 -1.06843133e-01 -1.16686694e+00 1.17174823e+00 -1.66210583 0.61507574 965.25 -3.71530521e-01 -1.07854262e+00 1.14074060e+00 -1.90254027 0.43428522 965.50 -3.77749747e-01 -9.61640998e-01 1.03317389e+00 -1.94509590 0.40831750 965.75 -3.73082206e-01 -5.70434677e-01 6.81605497e-01 -2.15000037 0.28642448 966.00 -3.28503540e-01 -4.32374555e-01 5.43012276e-01 -2.22051851 0.27924617 966.25 -3.73040355e-01 -4.04082018e-01 5.49946710e-01 -2.31627134 0.24111512 966.50 -4.99816114e-01 -4.31661729e-01 6.60415018e-01 -2.42923235 0.33901691 966.75 -5.30802921e-01 -3.02023863e-01 6.10712825e-01 -2.62428349 0.44010997 967.00 -5.78031714e-01 -2.63401975e-01 6.35217492e-01 -2.71401886 0.47487607 967.25 -5.72864520e-01 -1.80354372e-01 6.00584263e-01 -2.83658739 0.43455802 967.50 -4.12513483e-01 -9.22464428e-02 4.22701762e-01 -2.92159169 0.31073443 967.75 -3.07003524e-01 -5.78014577e-02 3.12397459e-01 -2.95549497 0.17466335 968.00 -3.16654356e-01 3.00789417e-03 3.16668641e-01 3.13209396 0.19125360 968.25 -2.58440369e-01 5.44339205e-02 2.64110727e-01 2.93400224 0.20000468 968.50 -2.46766897e-01 4.82796235e-02 2.51445468e-01 2.94838451 0.18538543 968.75 -2.06351395e-01 1.24825603e-02 2.06728597e-01 3.08117451 0.15098051 969.00 -1.53011069e-01 -6.69715305e-02 1.67025666e-01 -2.72902211 0.11374188 969.25 -1.88645028e-01 -1.16852477e-01 2.21904142e-01 -2.58700843 0.21525283 969.50 -2.28801014e-01 -1.34231297e-01 2.65269571e-01 -2.61103032 0.24211413 969.75 -1.35309790e-01 -1.30120859e-01 1.87723673e-01 -2.37574110 0.11488995 970.00 -8.88830347e-02 -3.86142229e-02 9.69084727e-02 -2.73175465 0.03367043 970.25 -1.25590626e-01 -1.20537586e-01 1.74075601e-01 -2.37672172 0.09094613 970.50 -1.16467255e-01 -1.86139885e-01 2.19573856e-01 -2.12989704 0.13939911 970.75 -1.63996444e-01 -1.40492433e-01 2.15946654e-01 -2.43323341 0.12236768 971.00 -2.91122619e-01 -4.33317468e-02 2.94329780e-01 -2.99383382 0.18595916 971.25 -3.23518874e-01 -3.25610258e-02 3.25153321e-01 -3.04128399 0.22340507 971.50 -2.76139675e-01 -1.43657611e-01 3.11272597e-01 -2.66188815 0.23462253 971.75 -1.79960016e-01 -2.18416315e-01 2.83004053e-01 -2.25996008 0.21714820 972.00 -1.21366454e-01 -2.07232748e-01 2.40156674e-01 -2.10059967 0.20643459 972.25 -8.43326582e-02 -1.32647262e-01 1.57185538e-01 -2.13710026 0.11910026 972.50 -1.20657122e-01 -2.28700344e-02 1.22805454e-01 -2.95426925 0.09089805 972.75 -1.72952375e-01 -9.94616454e-03 1.73238132e-01 -3.08414781 0.16189302 973.00 -1.95674314e-01 -8.74258653e-02 2.14316866e-01 -2.72140908 0.14015618 973.25 -7.17183230e-02 -7.57074734e-02 1.04283936e-01 -2.32914239 0.03224976 973.50 -1.14127080e-01 -5.45531379e-02 1.26495198e-01 -2.69569663 0.03734901 973.75 -1.47895713e-01 -8.72749642e-02 1.71726705e-01 -2.60847582 0.05761756 974.00 1.32717775e-02 -3.00978847e-03 1.36087804e-02 -0.22300908 0.00043480 974.25 -3.45290198e-02 6.20707379e-02 7.10283726e-02 2.07845206 0.00916503 974.50 -1.49546467e-01 -2.12062272e-01 2.59489023e-01 -2.18500419 0.06559002 974.75 -2.50816652e-01 -2.41351497e-01 3.48079787e-01 -2.37542367 0.13332928 975.00 -2.93983255e-01 -1.20404498e-01 3.17684430e-01 -2.75287008 0.16044323 975.25 -3.06630145e-01 -1.10453800e-01 3.25917303e-01 -2.79584380 0.13597288 975.50 -1.76897139e-01 -2.30130399e-02 1.78387774e-01 -3.01222642 0.02991535 975.75 -1.27796095e-01 -9.66380837e-02 1.60220976e-01 -2.49414193 0.01934587 976.00 -2.83458060e-01 -1.13947775e-01 3.05503793e-01 -2.75937051 0.06243241 976.25 -3.13948100e-01 -6.08023761e-02 3.19781704e-01 -2.95029083 0.08479726 976.50 -1.68677479e-01 1.99549077e-01 2.61288971e-01 2.27255150 0.04971268 976.75 -2.05610621e-01 2.45060646e-01 3.19891306e-01 2.26888091 0.06181623 977.00 -2.25384777e-01 4.07556061e-01 4.65725499e-01 2.07595167 0.12373984 977.25 -1.80242992e-01 3.89329016e-01 4.29027527e-01 2.00437374 0.12619442 977.50 4.33627376e-02 2.26816233e-01 2.30924079e-01 1.38189570 0.03411554 977.75 -1.86165964e-02 2.17763003e-01 2.18557322e-01 1.65607914 0.02923525 978.00 -2.57661740e-01 4.54191620e-01 5.22187323e-01 2.08682266 0.13918724 978.25 -5.91040582e-02 5.36135854e-01 5.39383856e-01 1.68059379 0.13929697 978.50 6.22767853e-02 2.79198048e-01 2.86059344e-01 1.35133303 0.02563214 978.75 1.72151014e-02 2.38857751e-01 2.39477316e-01 1.49884812 0.02314014 979.00 2.57418209e-01 2.31464258e-01 3.46178909e-01 0.73235963 0.04720792 979.25 5.32854990e-01 3.85973870e-01 6.57959169e-01 0.62688245 0.18323682 979.50 4.06510811e-01 5.12992014e-01 6.54531776e-01 0.90068766 0.13026994 979.75 2.51463943e-01 6.78500146e-01 7.23599725e-01 1.21587348 0.14748187 980.00 5.30597621e-01 6.05333656e-01 8.04961286e-01 0.85109622 0.19469123 980.25 7.33189198e-01 -1.01433459e-02 7.33259359e-01 -0.01383367 0.17765197 980.50 8.60165781e-01 -3.15844260e-01 9.16320232e-01 -0.35190601 0.25360969 980.75 9.99023745e-01 -2.08230209e-01 1.02049413e+00 -0.20549157 0.27324758 981.00 9.26382951e-01 -2.63306618e-01 9.63076189e-01 -0.27692765 0.26561028 981.25 1.00330935e+00 -3.08276878e-01 1.04960196e+00 -0.29810401 0.37711780 981.50 1.07176293e+00 -2.52291900e-01 1.10105722e+00 -0.23119002 0.44982176 981.75 1.07417575e+00 -4.30472205e-01 1.15722075e+00 -0.38114977 0.52119950 982.00 9.57347676e-01 -4.37029810e-01 1.05238283e+00 -0.42824668 0.51436504 982.25 6.28504388e-01 -5.73555566e-01 8.50872348e-01 -0.73971775 0.31699288 982.50 7.94554857e-01 -6.38063673e-01 1.01904007e+00 -0.67659518 0.41227066 982.75 7.76977417e-01 -6.37020190e-01 1.00473311e+00 -0.68673969 0.42446421 983.00 8.07505272e-01 -5.58412508e-01 9.81778637e-01 -0.60501740 0.41099589 983.25 6.73264975e-01 -6.08209201e-01 9.07305989e-01 -0.73467535 0.48961987 983.50 7.58357807e-01 -6.04114847e-01 9.69567591e-01 -0.67266999 0.52600423 983.75 5.15103933e-01 -4.18208940e-01 6.63498892e-01 -0.68195042 0.34056800 984.00 4.70856137e-01 -4.00759694e-01 6.18315319e-01 -0.70514961 0.31268443 984.25 6.03851644e-01 -4.93742935e-01 7.80012111e-01 -0.68541447 0.34090335 984.50 5.34638018e-01 -5.55867194e-01 7.71249731e-01 -0.80486299 0.25961112 984.75 4.78767398e-01 -5.47691059e-01 7.27450148e-01 -0.85244457 0.23288847 985.00 3.49823945e-01 -5.11305551e-01 6.19524139e-01 -0.97076835 0.18303935 985.25 2.78671053e-01 -6.38670801e-01 6.96819882e-01 -1.15936857 0.18692940 985.50 1.12824085e-01 -6.30680213e-01 6.40692443e-01 -1.39377615 0.13351972 985.75 -2.42496599e-01 -7.45543477e-01 7.83989590e-01 -1.88526474 0.17352588 986.00 -2.07339428e-01 -5.37487400e-01 5.76092305e-01 -1.93896412 0.12360357 986.25 -3.89454777e-01 -5.28039374e-01 6.56125448e-01 -2.20628089 0.20136651 986.50 -4.49957340e-01 -5.10377422e-01 6.80401882e-01 -2.29336166 0.23224103 986.75 -4.06817254e-01 -8.42224984e-01 9.35330531e-01 -2.02077342 0.39948036 987.00 -4.78122457e-01 -6.63555802e-01 8.17867584e-01 -2.19517885 0.34643684 987.25 -6.83598684e-01 -2.89041957e-01 7.42194323e-01 -2.74156651 0.26744333 987.50 -7.19673486e-01 -3.68471627e-01 8.08517944e-01 -2.66839251 0.28850491 987.75 -6.77977677e-01 -1.52857595e-01 6.94995809e-01 -2.91983937 0.24354815 988.00 -4.97491007e-01 2.97094596e-01 5.79450171e-01 2.60324494 0.18574417 988.25 -4.61395206e-01 3.18464709e-01 5.60629385e-01 2.53745990 0.13689976 988.50 -5.43055691e-01 3.70732054e-01 6.57534592e-01 2.54258719 0.17367532 988.75 -6.30012423e-01 5.76990750e-01 8.54303212e-01 2.40009463 0.29626656 989.00 -3.46533590e-01 7.09879562e-01 7.89945898e-01 2.02492577 0.25497393 989.25 -1.71050081e-01 8.34587177e-01 8.51935376e-01 1.77294859 0.31037094 989.50 -1.40395905e-01 1.01157655e+00 1.02127280e+00 1.70870455 0.35078163 989.75 7.21678971e-02 1.21960162e+00 1.22173496e+00 1.51169191 0.47906286 990.00 1.92265744e-01 1.23975144e+00 1.25457154e+00 1.41693790 0.50380544 990.25 4.14474905e-01 8.90029311e-01 9.81805287e-01 1.13497410 0.41816474 990.50 5.29809850e-01 8.95053977e-01 1.04010581e+00 1.03633133 0.55664291 990.75 4.44111220e-01 9.45858092e-01 1.04493172e+00 1.13181833 0.58513652 991.00 4.06995847e-01 9.02768116e-01 9.90270615e-01 1.14725156 0.55501341 991.25 2.43959117e-01 7.95033788e-01 8.31621774e-01 1.27306359 0.48887385 991.50 3.27764158e-01 6.92726510e-01 7.66354592e-01 1.12885779 0.45718361 991.75 4.76738099e-01 6.07045526e-01 7.71870122e-01 0.90505757 0.44358880 992.00 3.94645419e-01 5.82839089e-01 7.03879543e-01 0.97559942 0.43815815 992.25 2.67378434e-01 5.26407758e-01 5.90420490e-01 1.10082465 0.45026679 992.50 1.52438102e-01 5.30636269e-01 5.52098021e-01 1.29105509 0.53393208 992.75 1.34716217e-01 6.05005793e-01 6.19822933e-01 1.35170138 0.54764984 993.00 1.09258203e-01 4.88758651e-01 5.00821698e-01 1.35086983 0.48144656 993.25 8.99934499e-02 4.79072943e-01 4.87452260e-01 1.38511110 0.52361352 993.50 5.55572299e-02 4.19975504e-01 4.23634311e-01 1.43927315 0.46643145 993.75 3.73129923e-02 4.55834002e-01 4.57358609e-01 1.48912189 0.53323775 994.00 1.33498722e-01 4.37211080e-01 4.57138313e-01 1.27444623 0.41209534 994.25 1.53963765e-01 3.94346645e-01 4.23336884e-01 1.19856927 0.36314142 994.50 1.87625606e-01 5.07115037e-01 5.40711595e-01 1.21642848 0.44727112 994.75 1.82399495e-01 5.05233272e-01 5.37150105e-01 1.22433775 0.48956650 995.00 1.31768168e-01 4.32224591e-01 4.51863859e-01 1.27488642 0.44677402 995.25 6.20169232e-02 3.89744942e-01 3.94648221e-01 1.41299744 0.32714240 995.50 1.62647022e-01 2.72429998e-01 3.17288761e-01 1.03256854 0.17872151 995.75 1.61493779e-01 2.73773091e-01 3.17855229e-01 1.03784986 0.18462838 996.00 1.58633026e-01 2.63345184e-01 3.07433119e-01 1.02863102 0.11851648 996.25 1.42590990e-01 2.81282320e-01 3.15360008e-01 1.10161856 0.13601014 996.50 8.23095888e-02 4.16968416e-01 4.25014739e-01 1.37590196 0.22396966 996.75 1.73717397e-01 4.84501609e-01 5.14703355e-01 1.22652618 0.21143927 997.00 3.65227394e-01 3.95214745e-01 5.38131717e-01 0.82481184 0.22357337 997.25 3.46715438e-01 4.51072849e-01 5.68927333e-01 0.91546805 0.23113782 997.50 1.89450038e-01 3.89803166e-01 4.33402613e-01 1.11839949 0.17290386 997.75 1.89627680e-01 2.17456684e-01 2.88523944e-01 0.85365373 0.08253476 998.00 1.44652656e-01 -2.03070381e-02 1.46071101e-01 -0.13947335 0.01827479 998.25 3.18026701e-01 7.40193081e-02 3.26526937e-01 0.22867445 0.10030879 998.50 5.52069583e-01 5.89096102e-02 5.55203716e-01 0.10630460 0.23887320 998.75 3.33091804e-01 -2.54706474e-02 3.34064221e-01 -0.07631883 0.11650075 999.00 4.53327073e-01 -1.59785750e-01 4.80663001e-01 -0.33887662 0.23100607 999.25 3.28719901e-01 -1.86308598e-01 3.77846089e-01 -0.51562726 0.12188504 999.50 3.42176975e-01 -3.85420853e-01 5.15397241e-01 -0.84476210 0.19303908 999.75 1.80218627e-01 -3.06141170e-01 3.55248040e-01 -1.03874329 0.07364806 1000.00 -2.50115379e-01 0.00000000e+00 2.50115379e-01 3.14159265 0.03724282