========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0061 Injection acquisition : SIG0062 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -4.29060789e-03 0.00000000e+00 4.29060789e-03 3.14159265 0.05213441 0.25 -3.91535682e-03 -5.78809461e-04 3.95790847e-03 -2.99482506 0.04222467 0.50 -1.30757110e-03 -5.08783147e-03 5.25316773e-03 -1.82235200 0.02079788 0.75 7.82591818e-05 -5.45777362e-03 5.45833467e-03 -1.55645828 0.02134878 1.00 1.07413933e-03 3.49103479e-03 3.65254695e-03 1.27230399 0.01359834 1.25 7.64748835e-04 5.34234361e-04 9.32870373e-04 0.60976890 0.00104415 1.50 5.15516435e-04 -1.35501027e-03 1.44976206e-03 -1.20725437 0.00220604 1.75 -7.16476860e-04 -2.69213518e-04 7.65385530e-04 -2.78216787 0.00062051 2.00 -8.51046276e-05 1.99411929e-03 1.99593450e-03 1.61344825 0.00357293 2.25 -2.16390781e-03 -6.97956975e-04 2.27368444e-03 -2.82958310 0.00498272 2.50 -8.26803867e-05 -1.85241173e-03 1.85425598e-03 -1.61540064 0.00296627 2.75 -2.42401540e-03 -1.82499590e-03 3.03421500e-03 -2.49625005 0.00647920 3.00 -4.96371788e-03 -4.71510874e-04 4.98606234e-03 -3.04688536 0.01408080 3.25 -3.30316649e-03 -2.61831831e-04 3.31352754e-03 -3.06249113 0.00574467 3.50 -2.56530677e-03 -6.12046323e-04 2.63730915e-03 -2.90738508 0.00301830 3.75 -3.27448372e-03 -2.73767196e-03 4.26814848e-03 -2.44524608 0.00739206 4.00 -1.66015272e-03 -2.16872191e-03 2.73120152e-03 -2.22414272 0.00289106 4.25 -3.99845839e-03 -2.82929492e-03 4.89822205e-03 -2.52578658 0.00896890 4.50 -3.39572985e-03 -3.63077404e-03 4.97126758e-03 -2.32275587 0.00834627 4.75 -4.59092928e-03 -3.63595183e-04 4.60530489e-03 -3.06255902 0.00533283 5.00 -4.37708298e-03 -1.61307643e-04 4.38005429e-03 -3.10475655 0.00445422 5.25 -3.48742856e-03 -5.36255845e-04 3.52841725e-03 -2.98901941 0.00349654 5.50 -1.79558335e-03 -2.69223796e-04 1.81565443e-03 -2.99276464 0.00087648 5.75 -7.00420610e-03 1.05804568e-03 7.08366880e-03 2.99166755 0.01077137 6.00 -7.71103184e-03 -8.29255308e-05 7.71147772e-03 -3.13083893 0.01154426 6.25 -5.68095180e-03 6.43855369e-04 5.71732132e-03 3.02873839 0.00517624 6.50 -7.33007664e-03 3.64470017e-05 7.33016725e-03 3.13662044 0.00808677 6.75 -4.31484997e-03 -1.52686595e-03 4.57703505e-03 -2.80148052 0.00360803 7.00 -2.86749674e-03 -2.51157618e-03 3.81189618e-03 -2.42226582 0.00243799 7.25 6.32732117e-04 -1.59609752e-03 1.71693833e-03 -1.19337610 0.00041635 7.50 -8.03425145e-04 -1.82240068e-03 1.99164159e-03 -1.98602421 0.00053175 7.75 7.37245602e-04 1.12809645e-03 1.34763967e-03 0.99194311 0.00021631 8.00 -2.42737790e-04 8.14166031e-04 8.49581050e-04 1.86054845 0.00008659 8.25 -3.16911571e-03 -1.44000885e-03 3.48093664e-03 -2.71509548 0.00150997 8.50 -3.50427918e-03 -4.25639878e-03 5.51333866e-03 -2.25958205 0.00346406 8.75 3.55307953e-03 -9.05173942e-03 9.72411233e-03 -1.19674612 0.00965702 9.00 -4.32455613e-04 -6.02853486e-03 6.04402601e-03 -1.64240844 0.00347818 9.25 -5.93445812e-03 -6.13422575e-03 8.53501721e-03 -2.33964344 0.00584644 9.50 -3.28165244e-03 -3.52622544e-03 4.81700203e-03 -2.32028494 0.00188948 9.75 -6.26875677e-03 -2.58886449e-03 6.78229539e-03 -2.74994785 0.00354162 10.00 -3.35899799e-03 -5.97286742e-03 6.85259168e-03 -2.08309168 0.00375167 10.25 2.01259222e-03 -7.16504383e-03 7.44233703e-03 -1.29696212 0.00438369 10.50 -1.32551173e-03 -3.55621920e-03 3.79521757e-03 -1.92757591 0.00106185 10.75 -7.89565424e-03 -2.81056852e-04 7.90065496e-03 -3.10601128 0.00399408 11.00 -4.02401647e-03 -2.05447126e-03 4.51813686e-03 -2.66953881 0.00131609 11.25 -4.04006914e-04 -6.41281660e-03 6.42553019e-03 -1.63371309 0.00265657 11.50 4.14175583e-04 -6.67659568e-03 6.68942982e-03 -1.50884177 0.00298620 11.75 6.92490982e-04 -6.79841825e-03 6.83359601e-03 -1.46928583 0.00304657 12.00 3.34133961e-04 -5.41440722e-03 5.42470746e-03 -1.50916248 0.00166432 12.25 -1.16672130e-03 -1.54410662e-03 1.93533042e-03 -2.21786948 0.00019639 12.50 -2.19210780e-03 1.82319168e-03 2.85120404e-03 2.44781487 0.00038533 12.75 -7.61362749e-03 7.44826103e-04 7.64997316e-03 3.04407494 0.00266747 13.00 -6.52695773e-03 -9.98816730e-03 1.19316664e-02 -2.14960635 0.00598435 13.25 -4.36497495e-03 -1.75062038e-02 1.80421777e-02 -1.81515254 0.01180544 13.50 -3.93335689e-04 4.69756482e-04 6.12685985e-04 2.26788177 0.00001302 13.75 -3.95439237e-04 -7.22452553e-04 8.23595703e-04 -2.07160786 0.00001790 14.00 2.57615113e-03 1.03826592e-02 1.06974841e-02 1.32758734 0.00243521 14.25 4.76245329e-03 2.36782337e-02 2.41524267e-02 1.37231243 0.01058123 14.50 3.50777998e-03 -5.76404521e-04 3.55482244e-03 -0.16286627 0.00022243 14.75 9.52909247e-03 -6.67029006e-03 1.16316969e-02 -0.61072071 0.00267504 15.00 -1.40905980e-02 -1.81453263e-02 2.29738508e-02 -2.23106871 0.01118111 15.25 -1.25562636e-02 -5.07760890e-03 1.35440713e-02 -2.75730880 0.00378377 15.50 2.64306812e-03 3.78329512e-02 3.79251632e-02 1.50104811 0.02895731 15.75 -3.93925172e-03 2.41323643e-02 2.44517629e-02 1.73260445 0.01140441 16.00 -2.42922562e-04 -1.69738486e-02 1.69755868e-02 -1.58510693 0.00598828 16.25 -1.80160979e-03 -1.13649384e-02 1.15068511e-02 -1.72801161 0.00338033 16.50 9.10602581e-03 -7.91859908e-04 9.14039103e-03 -0.08674178 0.00211398 16.75 2.80209984e-03 4.88392807e-03 5.63067642e-03 1.04991026 0.00076446 17.00 -3.26083788e-02 1.91880703e-02 3.78350157e-02 2.60971661 0.02482388 17.25 -3.13252977e-02 1.01568562e-02 3.29307759e-02 2.82804999 0.01784868 17.50 -1.90395440e-02 -1.71865275e-02 2.56491902e-02 -2.40730141 0.01097488 17.75 -1.52179556e-02 -9.44861399e-03 1.79126346e-02 -2.58595727 0.00549855 18.00 -2.43438331e-02 1.14074969e-03 2.43705461e-02 3.09476700 0.01103416 18.25 -1.53188412e-02 -4.47319795e-03 1.59585838e-02 -2.85748558 0.00472406 18.50 -7.13151172e-03 -2.06602225e-02 2.18564236e-02 -1.90317142 0.00832163 18.75 -7.90350141e-03 -1.03398677e-02 1.30145379e-02 -2.22343200 0.00287749 19.00 1.61302311e-03 -9.07539112e-03 9.21762266e-03 -1.39489726 0.00141798 19.25 -3.62208288e-03 -7.39479072e-03 8.23422214e-03 -2.02626317 0.00129838 19.50 1.58421685e-02 -1.02815396e-03 1.58754970e-02 -0.06480893 0.00526289 19.75 2.28048869e-03 5.44362941e-03 5.90201066e-03 1.17407995 0.00060770 20.00 -5.82936255e-03 -6.39024057e-03 8.64966140e-03 -2.31032683 0.00101975 20.25 -6.31771922e-04 3.22064295e-03 3.28202327e-03 1.76450004 0.00015793 20.50 -2.11064816e-03 -1.22944172e-02 1.24742747e-02 -1.74081431 0.00182315 20.75 -1.08128494e-02 -2.33751828e-02 2.57549390e-02 -2.00406089 0.00817302 21.00 -3.71993381e-02 -1.69131267e-02 4.08637322e-02 -2.71486855 0.01577084 21.25 -8.59327554e-03 7.67014185e-04 8.62743851e-03 3.05257107 0.00089922 21.50 9.77242594e-03 1.76348642e-02 2.01615661e-02 1.06476966 0.00454789 21.75 6.55078729e-03 3.18436000e-04 6.55852237e-03 0.04857211 0.00043715 22.00 -1.42998248e-03 1.40757975e-03 2.00652203e-03 2.36408939 0.00003093 22.25 -1.11163118e-02 -1.21698686e-02 1.64826603e-02 -2.31098146 0.00238587 22.50 2.50485524e-03 -1.74567014e-02 1.76354961e-02 -1.42827951 0.00224434 22.75 1.07892260e-02 -8.37645840e-03 1.36591527e-02 -0.66016698 0.00162746 23.00 -2.65341629e-03 -2.75206494e-02 2.76482687e-02 -1.66691469 0.00718792 23.25 2.38205723e-02 -5.01947055e-03 2.43436798e-02 -0.20768167 0.00493699 23.50 2.05016282e-02 1.05271355e-02 2.30464171e-02 0.47437180 0.00378629 23.75 9.67798839e-03 1.01463452e-02 1.40218323e-02 0.80901912 0.00143206 24.00 1.84191973e-02 -1.54325714e-04 1.84198438e-02 -0.00837833 0.00251477 24.25 3.34106647e-02 -4.99944355e-04 3.34144050e-02 -0.01496250 0.00878013 24.50 3.38599862e-02 2.50049218e-02 4.20920987e-02 0.63608743 0.01044953 24.75 4.02918623e-02 1.77514609e-02 4.40289511e-02 0.41498588 0.01098614 25.00 3.29871084e-02 -1.38569611e-03 3.30162001e-02 -0.04198252 0.00639254 25.25 5.12175383e-03 -3.38856588e-02 3.42705448e-02 -1.42078371 0.00962795 25.50 5.39716764e-03 -3.47968650e-02 3.52129413e-02 -1.41691749 0.00989623 25.75 1.33107189e-02 -2.85600819e-03 1.36136703e-02 -0.21135990 0.00120827 26.00 3.42678724e-03 7.11701344e-03 7.89903482e-03 1.12206419 0.00039441 26.25 -2.30179407e-02 -2.08946271e-02 3.10871523e-02 -2.40451007 0.00721506 26.50 -2.18752103e-02 -2.59864216e-02 3.39679104e-02 -2.27050697 0.00894000 26.75 -1.26737255e-02 -4.91159603e-03 1.35921703e-02 -2.77187219 0.00175986 27.00 -2.10759619e-02 -2.31735557e-02 3.13242694e-02 -2.30882618 0.01025417 27.25 -7.22629462e-03 3.62991505e-03 8.08675567e-03 2.67609047 0.00065556 27.50 1.80744902e-03 5.14018441e-04 1.87911866e-03 0.27707387 0.00003330 27.75 3.00539561e-02 -9.73688943e-03 3.15918865e-02 -0.31330933 0.00802985 28.00 1.00973524e-02 -2.38537426e-03 1.03752848e-02 -0.23198446 0.00084828 28.25 2.60652919e-03 1.91572093e-02 1.93337183e-02 1.43556675 0.00327109 28.50 -9.28898204e-03 1.30842683e-02 1.60462851e-02 2.18815910 0.00227332 28.75 1.20832629e-02 -1.68740891e-02 2.07542797e-02 -0.94935719 0.00407390 29.00 1.07968818e-02 6.08033587e-04 1.08139892e-02 0.05625624 0.00109153 29.25 1.95287791e-04 3.86872018e-02 3.86876947e-02 1.56574850 0.01274983 29.50 -3.54617595e-03 8.65197760e-03 9.35051230e-03 1.95978126 0.00067471 29.75 -1.51411854e-03 -1.05999841e-02 1.07075776e-02 -1.71267814 0.00077743 30.00 -3.69804365e-04 -7.99389991e-03 8.00244906e-03 -1.61702419 0.00042973 30.25 -1.24389984e-03 2.19006520e-02 2.19359487e-02 1.62753276 0.00294395 30.50 -1.82049785e-03 1.29054558e-02 1.30332268e-02 1.71093586 0.00127059 30.75 2.48025916e-02 1.44131597e-02 2.86863683e-02 0.52641777 0.00521312 31.00 6.22171956e-03 7.66499128e-03 9.87227865e-03 0.88895821 0.00063327 31.25 9.91872653e-03 3.60616822e-02 3.74008831e-02 1.30238464 0.00761456 31.50 9.62187483e-04 1.87047989e-02 1.87295303e-02 1.51940095 0.00236684 31.75 -4.17887459e-03 3.07583433e-02 3.10409194e-02 1.70583104 0.00742827 32.00 -3.32700240e-02 5.38984822e-03 3.37037826e-02 2.98098487 0.00756648 32.25 -7.16733828e-02 1.09199000e-02 7.25004691e-02 2.99039894 0.02296838 32.50 -3.02949523e-02 -1.52272523e-02 3.39065385e-02 -2.67584061 0.00493224 32.75 -6.44428558e-02 -6.03049880e-02 8.82585590e-02 -2.38935219 0.02727920 33.00 -1.16355203e-02 5.17820287e-03 1.27357417e-02 2.72287607 0.00086324 33.25 6.10996569e-04 3.33619326e-02 3.33675271e-02 1.55248419 0.00558481 33.50 -8.81571655e-03 2.94082145e-02 3.07011390e-02 1.86204260 0.00465450 33.75 1.05756371e-02 2.32161901e-02 2.55114794e-02 1.14335439 0.00277893 34.00 -9.65168070e-03 2.15507633e-02 2.36133509e-02 1.99186750 0.00223604 34.25 -2.31925342e-02 5.42962760e-02 5.90421818e-02 1.97448476 0.01218982 34.50 -3.57960448e-02 7.25303606e-03 3.65234631e-02 2.94167802 0.00521342 34.75 -4.14750294e-02 5.35461691e-04 4.14784857e-02 3.12868291 0.00618898 35.00 -2.79179514e-02 1.01719767e-01 1.05481387e-01 1.83865992 0.04216492 35.25 6.47950699e-03 1.16761442e-01 1.16941089e-01 1.51535964 0.05075422 35.50 -1.87892300e-02 1.68994233e-02 2.52710442e-02 2.40909767 0.00280435 35.75 -8.28398083e-03 3.31286392e-02 3.41486613e-02 1.81582672 0.00486318 36.00 2.33818413e-02 9.08328908e-03 2.50841911e-02 0.37053277 0.00252064 36.25 7.06370858e-02 -4.93483654e-02 8.61676218e-02 -0.60979809 0.02051840 36.50 7.16080282e-02 -1.31348853e-01 1.49600237e-01 -1.07166556 0.02906116 36.75 3.69315640e-02 -7.50574006e-02 8.36513825e-02 -1.11353353 0.01456657 37.00 -4.30339951e-02 -1.39503370e-02 4.52386630e-02 -2.82811150 0.00701552 37.25 -3.53043897e-02 5.89870345e-02 6.87449647e-02 2.11012026 0.01579821 37.50 -2.35799232e-02 8.26168441e-02 8.59159805e-02 1.84881744 0.02222602 37.75 -3.54994254e-02 6.28037377e-02 7.21423500e-02 2.08526768 0.01420166 38.00 -3.81809649e-02 1.99288729e-02 4.30690847e-02 2.66053309 0.00384100 38.25 -1.29889077e-02 -5.27730563e-03 1.40200456e-02 -2.75567285 0.00056517 38.50 -5.84833525e-02 1.79158883e-02 6.11660165e-02 2.84432801 0.00943071 38.75 -2.42271541e-02 1.25457783e-02 2.72828068e-02 2.66377548 0.00189434 39.00 -2.26074462e-02 4.74026374e-02 5.25176794e-02 2.01581314 0.00753071 39.25 -3.88714923e-02 5.18593530e-02 6.48103804e-02 2.21401325 0.01119999 39.50 7.35934697e-02 6.44495111e-02 9.78250391e-02 0.71925485 0.02395364 39.75 2.72653140e-02 1.89861505e-02 3.32245580e-02 0.60827084 0.00403991 40.00 -2.11518389e-02 5.97243558e-02 6.33592848e-02 1.91117027 0.01556123 40.25 -1.67347627e-03 6.36421189e-02 6.36641172e-02 1.59708537 0.01596144 40.50 -4.35265569e-02 7.18056474e-02 8.39679234e-02 2.11574154 0.01960739 40.75 -3.59476519e-02 -5.20293024e-03 3.63222268e-02 -2.99785451 0.00441544 41.00 5.85541774e-03 -1.08160603e-01 1.08318983e-01 -1.51671279 0.03680114 41.25 -9.36723325e-03 -7.86573688e-02 7.92131726e-02 -1.68932716 0.02086877 41.50 1.34975510e-02 -1.04520559e-01 1.05388478e-01 -1.44236933 0.03299463 41.75 6.61736219e-03 -3.20594965e-03 7.35306708e-03 -0.45115103 0.00016197 42.00 -1.91082015e-02 7.37293741e-02 7.61652412e-02 1.82438373 0.01702366 42.25 -1.54444515e-02 5.84209722e-02 6.04279826e-02 1.82924849 0.01466131 42.50 -4.20800217e-02 8.42764303e-02 9.41979030e-02 2.03389138 0.03940895 42.75 -2.20810930e-02 4.25322717e-02 4.79225292e-02 2.04965490 0.00741766 43.00 1.64306978e-02 5.41507048e-02 5.65885736e-02 1.27619996 0.00798175 43.25 3.13086572e-02 5.78800721e-02 6.58052791e-02 1.07494879 0.01108810 43.50 6.60930488e-02 6.04479840e-02 8.95670132e-02 0.74081717 0.01847143 43.75 -1.17415253e-02 2.12623515e-02 2.42889071e-02 2.07534342 0.00177192 44.00 4.22983957e-03 1.22775633e-02 1.29857654e-02 1.23901372 0.00052058 44.25 -9.52268600e-03 3.68027281e-02 3.80147648e-02 1.82399267 0.00555096 44.50 -4.48946923e-02 6.99630039e-02 8.31285470e-02 2.14130886 0.02381742 44.75 -4.70310806e-02 1.06245085e-01 1.16189245e-01 1.98753453 0.04389249 45.00 -9.43148909e-02 1.13108226e-01 1.47271075e-01 2.26583734 0.06728073 45.25 -7.82146341e-02 1.08239043e-02 7.89600272e-02 3.00407886 0.02024554 45.50 -9.29588544e-02 -3.75593701e-02 1.00259937e-01 -2.75760584 0.03205366 45.75 -2.76852565e-02 -4.28710978e-02 5.10333661e-02 -2.14419854 0.00742295 46.00 1.37573048e-02 -2.76250871e-02 3.08611223e-02 -1.10874967 0.00317254 46.25 -3.72052430e-03 -1.32618474e-02 1.37738484e-02 -1.84430889 0.00064955 46.50 -1.72837064e-02 -1.84494913e-02 2.52806297e-02 -2.32358135 0.00215016 46.75 -5.57030908e-02 -1.42611571e-02 5.74996950e-02 -2.89095531 0.00923518 47.00 -5.60925909e-02 9.20514646e-03 5.68428841e-02 2.97893619 0.00878652 47.25 -1.16779689e-02 -3.06848957e-02 3.28319628e-02 -1.93444753 0.00258733 47.50 2.87073443e-04 -2.38667642e-02 2.38684906e-02 -1.55876874 0.00155916 47.75 -9.70107431e-02 5.69281144e-02 1.12480641e-01 2.61091863 0.02940044 48.00 -8.90609743e-02 5.52498024e-02 1.04806478e-01 2.58633744 0.02472248 48.25 -1.81905667e-01 6.74214816e-02 1.93998268e-01 2.78665009 0.07011833 48.50 -1.75390462e-01 8.36817204e-02 1.94330761e-01 2.69641869 0.05538211 48.75 -2.93811238e-01 1.67900086e-01 3.38401363e-01 2.62242614 0.09805952 49.00 -3.16685547e-01 1.70115181e-01 3.59484228e-01 2.64865011 0.08145519 49.25 -3.35728902e-01 9.18553310e-02 3.48067950e-01 2.87452874 0.03078606 49.50 -6.40209784e-01 -5.56451411e-02 6.42623489e-01 -3.05489350 0.05464356 49.75 -1.77701072e+00 -1.57508677e-01 1.78397760e+00 -3.05318682 0.09327952 50.00 -1.09819869e+00 3.58075872e-01 1.15510116e+00 2.82640462 0.04497008 50.25 -1.54864080e-01 1.43337644e-01 2.11017922e-01 2.39482841 0.00481557 50.50 -1.73574143e-01 1.96155882e-01 2.61925778e-01 2.29519397 0.02249230 50.75 4.60243879e-02 7.48482768e-02 8.78664260e-02 1.01949115 0.00468670 51.00 -6.02078026e-02 7.77484315e-02 9.83351316e-02 2.22972675 0.00888652 51.25 -1.69201808e-01 2.16512150e-01 2.74784939e-01 2.23414756 0.06850375 51.50 -1.50430127e-01 1.16318035e-01 1.90155485e-01 2.48338541 0.03998644 51.75 -1.24646785e-01 1.84770475e-01 2.22883264e-01 2.16427346 0.04044111 52.00 -1.07328658e-01 1.57045481e-01 1.90217570e-01 2.17031065 0.03977239 52.25 -9.96930710e-02 8.83490338e-02 1.33207583e-01 2.41644858 0.01760128 52.50 -7.75636852e-02 6.06925616e-02 9.84871174e-02 2.47762208 0.01144056 52.75 -1.68138509e-01 1.45032491e-01 2.22047251e-01 2.42984188 0.05325437 53.00 -2.05629585e-01 1.50530904e-01 2.54839321e-01 2.50967961 0.05833884 53.25 -2.28150309e-01 1.14039198e-01 2.55063721e-01 2.67807113 0.05157595 53.50 -1.26850568e-01 1.35142440e-01 1.85349793e-01 2.32455584 0.03511343 53.75 -2.11887927e-01 1.05299006e-01 2.36610173e-01 2.68038310 0.04896794 54.00 -1.45438083e-01 1.80922722e-01 2.32132004e-01 2.24789168 0.05331332 54.25 -2.64778520e-01 3.94160879e-01 4.74837302e-01 2.16231157 0.16046688 54.50 -1.63878412e-01 2.08306742e-01 2.65043077e-01 2.23738511 0.05830642 54.75 -8.18860706e-02 1.53000635e-01 1.73535365e-01 2.06220648 0.02600724 55.00 3.34036675e-02 2.30694382e-01 2.33100200e-01 1.42699952 0.04014256 55.25 3.82351539e-02 3.38342206e-01 3.40495779e-01 1.45826639 0.06342533 55.50 -6.94738491e-02 -4.14960673e-02 8.09230456e-02 -2.60316784 0.00465715 55.75 4.91918648e-02 6.56579886e-02 8.20415201e-02 0.92779864 0.00409816 56.00 8.58004444e-02 1.68217523e-01 1.88835514e-01 1.09913591 0.02309286 56.25 9.48686254e-02 1.09380285e-01 1.44789857e-01 0.85632787 0.01517799 56.50 3.21635756e-03 2.49534588e-01 2.49555316e-01 1.55790761 0.06296357 56.75 6.61610285e-03 2.51719722e-01 2.51806655e-01 1.54451877 0.06093886 57.00 8.80299212e-02 1.68022995e-01 1.89686568e-01 1.08819955 0.02668313 57.25 1.25339577e-01 1.25353797e-01 1.77266985e-01 0.78545489 0.02323819 57.50 1.37635275e-01 2.33742091e-01 2.71254187e-01 1.03862763 0.05154545 57.75 1.42524000e-01 8.86512204e-02 1.67845552e-01 0.55644564 0.02137521 58.00 2.45609877e-01 -5.32521277e-02 2.51316535e-01 -0.21351118 0.04516430 58.25 1.58659868e-01 -2.90611553e-01 3.31101236e-01 -1.07106654 0.07536047 58.50 1.16594075e-01 -8.76377336e-01 8.84099210e-01 -1.43853208 0.25786064 58.75 -4.87163431e-01 -1.02030062e+00 1.13063768e+00 -2.01625843 0.23402254 59.00 -1.87325306e+00 -5.36735915e-01 1.94863092e+00 -2.86254260 0.35358071 59.25 -1.91499410e+00 3.23516138e-01 1.94212901e+00 2.97423441 0.37591883 59.50 -1.51319439e+00 7.28138589e-01 1.67926861e+00 2.69310350 0.40255519 59.75 -1.04530878e+00 6.35980828e-01 1.22357757e+00 2.59500912 0.36167215 60.00 -9.20874863e-01 6.17776993e-01 1.10889987e+00 2.55069343 0.32450843 60.25 -7.20307536e-01 5.95830046e-01 9.34802861e-01 2.45049187 0.29593590 60.50 -7.01602245e-01 5.12404802e-01 8.68794792e-01 2.51079627 0.34092672 60.75 -6.11494880e-01 4.85713115e-01 7.80924592e-01 2.47033426 0.29664328 61.00 -6.99485382e-01 5.35527495e-01 8.80948068e-01 2.48818073 0.35692885 61.25 -4.81511182e-01 3.90955920e-01 6.20241526e-01 2.45961635 0.23439812 61.50 -5.80475237e-01 2.41079091e-01 6.28546441e-01 2.74795525 0.22227154 61.75 -5.68159041e-01 2.98946504e-01 6.42007561e-01 2.65723129 0.22733063 62.00 -6.44856443e-01 5.16981723e-01 8.26504648e-01 2.46581569 0.29450617 62.25 -5.46410596e-01 4.29136665e-01 6.94782568e-01 2.47583386 0.26689753 62.50 -6.45466459e-01 4.79902583e-01 8.04321726e-01 2.50226627 0.37178304 62.75 -5.16254030e-01 4.36636878e-01 6.76143466e-01 2.43955414 0.29720706 63.00 -6.64657831e-01 5.49016205e-01 8.62084002e-01 2.45118998 0.44643020 63.25 -7.91364163e-01 5.56113991e-01 9.67222833e-01 2.52903796 0.46296627 63.50 -9.62750245e-01 7.47725251e-01 1.21900824e+00 2.48124914 0.62683384 63.75 -9.06726291e-01 5.38591780e-01 1.05462490e+00 2.60559956 0.50582119 64.00 -8.22176969e-01 5.24067905e-01 9.74998532e-01 2.57411549 0.47608813 64.25 -8.30462434e-01 4.43218432e-01 9.41334390e-01 2.65134931 0.42065850 64.50 -9.51622898e-01 3.38759012e-01 1.01012069e+00 2.79960013 0.45788241 64.75 -6.92023008e-01 3.09997307e-01 7.58283703e-01 2.72043808 0.26203368 65.00 -6.53623658e-01 5.01284810e-01 8.23717395e-01 2.48734293 0.23832178 65.25 -4.09907798e-01 3.44659233e-01 5.35550548e-01 2.44245146 0.13607957 65.50 -6.39496670e-01 4.64227570e-01 7.90229857e-01 2.51367745 0.27382142 65.75 -6.37126008e-01 5.80972088e-01 8.62240174e-01 2.40226155 0.30713804 66.00 -8.34545703e-01 6.12515758e-01 1.03520147e+00 2.50844219 0.35047585 66.25 -6.23824552e-01 7.59630435e-01 9.82952425e-01 2.25834370 0.34596760 66.50 -6.79675069e-01 9.22722923e-01 1.14602609e+00 2.20566428 0.47581431 66.75 -7.37644746e-01 8.78110198e-01 1.14682051e+00 2.26947764 0.58438422 67.00 -7.94776103e-01 7.69282406e-01 1.10610328e+00 2.37249275 0.57827622 67.25 -7.70478724e-01 3.57687180e-01 8.49457229e-01 2.70695990 0.34507604 67.50 -7.87057797e-01 6.06241591e-01 9.93473121e-01 2.48524878 0.41990790 67.75 -1.10993090e+00 7.12064482e-01 1.31870483e+00 2.57118809 0.53963761 68.00 -1.42671918e+00 8.03596265e-01 1.63746590e+00 2.62863541 0.60576424 68.25 -2.15985348e+00 1.61022022e+00 2.69402603e+00 2.50096305 0.54920538 68.50 -1.46005126e+00 2.26350119e+00 2.69354549e+00 2.14367759 0.38715665 68.75 8.59472376e-01 6.43348052e-01 1.07358720e+00 0.64256501 0.17495560 69.00 6.06939241e-01 3.86032887e-01 7.19302879e-01 0.56649326 0.22602795 69.25 4.17821810e-02 4.16106057e-01 4.18198519e-01 1.47071944 0.25468406 69.50 -9.59963144e-02 3.24168877e-01 3.38083944e-01 1.85869942 0.20653953 69.75 -3.33413141e-01 3.01888813e-01 4.49779032e-01 2.40577484 0.40705629 70.00 -4.31995207e-01 2.77138644e-01 5.13250121e-01 2.57119356 0.49436026 70.25 -6.52758686e-01 3.14213535e-01 7.24447409e-01 2.69296593 0.70770375 70.50 -6.88050871e-01 3.02512314e-01 7.51616725e-01 2.72736596 0.70482573 70.75 -7.98076196e-01 2.99633593e-01 8.52470471e-01 2.78243204 0.81726751 71.00 -8.54020450e-01 3.18263504e-01 9.11395955e-01 2.78487070 0.75648403 71.25 -8.65848014e-01 4.19910251e-01 9.62297979e-01 2.69004124 0.67855322 71.50 -7.06746821e-01 3.74020981e-01 7.99614134e-01 2.65484717 0.52237417 71.75 -6.60273433e-01 3.80194433e-01 7.61911290e-01 2.61914713 0.54278806 72.00 -6.14602952e-01 3.03937429e-01 6.85649145e-01 2.68233345 0.43921573 72.25 -6.86944359e-01 3.80503713e-01 7.85286972e-01 2.63575430 0.62665930 72.50 -6.74438724e-01 3.69087741e-01 7.68825957e-01 2.64086191 0.63194593 72.75 -7.68373842e-01 2.87470503e-01 8.20388720e-01 2.78358631 0.69685032 73.00 -7.90187576e-01 2.52519992e-01 8.29555756e-01 2.83228010 0.74597663 73.25 -8.04582004e-01 2.84281931e-01 8.53327848e-01 2.80195546 0.85666372 73.50 -8.88950391e-01 1.97332830e-01 9.10589393e-01 2.92315066 0.84108928 73.75 -9.90601927e-01 1.48582459e-01 1.00168305e+00 2.99271044 0.88765790 74.00 -1.08460988e+00 1.90735272e-01 1.10125317e+00 2.96751644 0.83741459 74.25 -1.19126859e+00 2.13218026e-01 1.21019948e+00 2.96448400 0.87093112 74.50 -1.28022579e+00 2.26842209e-01 1.30016748e+00 2.96622361 0.82010888 74.75 -1.45780045e+00 1.91669114e-01 1.47034663e+00 3.01086420 0.84402183 75.00 -1.36408005e+00 2.53614095e-01 1.38745612e+00 2.95776841 0.66801282 75.25 -1.23531229e+00 4.25526460e-01 1.30654860e+00 2.80985394 0.60689098 75.50 -1.16509314e+00 4.80188741e-01 1.26016795e+00 2.75065944 0.41592762 75.75 -1.32150705e+00 7.25784991e-01 1.50769517e+00 2.63935611 0.45668501 76.00 -1.07691429e+00 9.84725516e-01 1.45925623e+00 2.40088096 0.34668374 76.25 -9.52958465e-01 8.66636173e-01 1.28809475e+00 2.40359935 0.20447268 76.50 -3.92768722e-01 4.27668334e-01 5.80661238e-01 2.31368229 0.06509865 76.75 -5.73057558e-01 7.15947853e-01 9.17047596e-01 2.24579210 0.20269664 77.00 -1.24502558e+00 1.06987424e+00 1.64156011e+00 2.43171320 0.51335058 77.25 -1.62865008e+00 1.22840204e+00 2.03996879e+00 2.49537994 0.61964312 77.50 -2.30936316e+00 1.72424615e+00 2.88204493e+00 2.50025008 0.60140313 77.75 -2.67736973e+00 2.70507245e+00 3.80601177e+00 2.35104767 0.55126468 78.00 -2.98724580e+00 7.06463487e+00 7.67024793e+00 1.97084029 0.56126401 78.25 -1.14598799e+00 9.99214947e+00 1.00576508e+01 1.68498624 0.62790506 78.50 5.10117093e+00 9.56190962e+00 1.08375302e+01 1.08071803 0.56467133 78.75 6.69958819e+00 6.12275656e+00 9.07593686e+00 0.74044204 0.53259024 79.00 6.81002170e+00 6.24563806e-01 6.83860187e+00 0.09145661 0.50851514 79.25 5.90630604e+00 -5.59074662e-01 5.93270727e+00 -0.09437605 0.57882406 79.50 4.55040346e+00 -3.71608197e-01 4.56555191e+00 -0.08148407 0.54466444 79.75 3.77174441e+00 -8.16171382e-01 3.85904024e+00 -0.21310528 0.42683210 80.00 3.19946274e+00 -1.60949719e+00 3.58148615e+00 -0.46608649 0.56252022 80.25 2.69513360e+00 -1.75562802e+00 3.21651595e+00 -0.57736346 0.52277280 80.50 2.63726647e+00 -2.58769660e+00 3.69477308e+00 -0.77591132 0.53415716 80.75 2.46321305e+00 -2.03923418e+00 3.19779526e+00 -0.69150871 0.43931838 81.00 2.16782261e+00 -2.30043886e+00 3.16092927e+00 -0.81506906 0.45144270 81.25 1.04349863e+00 -2.49101741e+00 2.70075122e+00 -1.17409985 0.41304900 81.50 4.47141418e-01 -2.61864427e+00 2.65654536e+00 -1.40167439 0.39122666 81.75 9.69310708e-02 -2.38274675e+00 2.38471753e+00 -1.53013835 0.35614004 82.00 -2.05759326e-01 -2.24756491e+00 2.25696365e+00 -1.66208952 0.32351868 82.25 -3.66958737e-01 -1.43082249e+00 1.47712955e+00 -1.82185225 0.20743151 82.50 -9.49070526e-01 -1.43366305e+00 1.71933842e+00 -2.15555421 0.21873838 82.75 -6.64853886e-01 -1.09498853e+00 1.28102715e+00 -2.11647769 0.17482660 83.00 -9.60034395e-01 -1.08050277e+00 1.44539001e+00 -2.29722536 0.20719281 83.25 -9.80493418e-01 -6.38604412e-01 1.17012091e+00 -2.56429761 0.17232394 83.50 -1.26695436e+00 -6.35644846e-01 1.41746877e+00 -2.67657724 0.23109372 83.75 -7.82292872e-01 -3.78314808e-01 8.68967336e-01 -2.69115301 0.14661784 84.00 -1.01123651e+00 -5.39810007e-01 1.14629583e+00 -2.65126287 0.22930924 84.25 -8.28755363e-01 -1.66359024e-01 8.45287393e-01 -2.94349184 0.17903716 84.50 -6.67450362e-01 -2.50886722e-01 7.13045674e-01 -2.78204351 0.15157529 84.75 -5.99070207e-01 -4.41724403e-01 7.44315498e-01 -2.50623684 0.19158185 85.00 -9.54678655e-01 -4.99058815e-01 1.07725161e+00 -2.65991068 0.25660584 85.25 -1.17218612e+00 -5.52044076e-01 1.29567471e+00 -2.70145183 0.33087068 85.50 -1.45644120e+00 -5.91674017e-01 1.57203661e+00 -2.75571306 0.45089715 85.75 -1.20395500e+00 -4.06340789e-01 1.27067717e+00 -2.81609234 0.39649616 86.00 -1.29423193e+00 -3.77631785e-01 1.34819956e+00 -2.85769354 0.42693169 86.25 -1.05924991e+00 -3.04088279e-01 1.10203450e+00 -2.86203184 0.37954951 86.50 -1.00123560e+00 -3.51203561e-01 1.06104508e+00 -2.80423190 0.42405045 86.75 -9.28668136e-01 -3.29519817e-01 9.85397289e-01 -2.80062096 0.37305895 87.00 -8.80242545e-01 -3.65022565e-01 9.52926235e-01 -2.74849203 0.37090320 87.25 -6.98295563e-01 -4.04971917e-01 8.07229179e-01 -2.61605120 0.27112077 87.50 -6.00373585e-01 -3.75863044e-01 7.08322998e-01 -2.58223964 0.23346717 87.75 -4.40325582e-01 -1.79307312e-01 4.75434254e-01 -2.75488171 0.09328961 88.00 -4.28902622e-01 -2.43598665e-01 4.93252237e-01 -2.62506675 0.08908181 88.25 -5.21910965e-01 1.88610704e-02 5.22251659e-01 3.10546989 0.08602405 88.50 -5.04346076e-01 -3.39815224e-02 5.05489573e-01 -3.07431694 0.08456654 88.75 -4.39709540e-01 -1.73311381e-01 4.72632325e-01 -2.76613979 0.09205106 89.00 -4.72652335e-01 -1.02349571e-01 4.83606931e-01 -2.92834210 0.10078776 89.25 -4.41862284e-01 -2.73895707e-02 4.42710364e-01 -3.07968519 0.07788019 89.50 -5.65835208e-01 -2.31282929e-02 5.66307690e-01 -3.10074079 0.12825131 89.75 -9.29727479e-01 1.51601296e-01 9.42006443e-01 2.97995527 0.35512927 90.00 -9.97288897e-01 1.01255194e-01 1.00241596e+00 3.04040893 0.44883598 90.25 -1.17869362e+00 -2.97452706e-02 1.17906889e+00 -3.11636221 0.59638369 90.50 -1.16249082e+00 -1.58433540e-01 1.17323744e+00 -3.00613920 0.61650739 90.75 -1.24179096e+00 -2.85231314e-01 1.27412782e+00 -2.91581538 0.67534618 91.00 -1.33905813e+00 -1.57089526e-01 1.34824100e+00 -3.02481298 0.64798946 91.25 -1.43472233e+00 -7.49332302e-02 1.43667781e+00 -3.08941168 0.75711916 91.50 -1.35368857e+00 -1.21132054e-01 1.35909739e+00 -3.05234739 0.71180719 91.75 -1.40578083e+00 -1.34893985e-01 1.41223798e+00 -3.04592892 0.81417791 92.00 -1.41834458e+00 -1.65321447e-01 1.42794696e+00 -3.02555682 0.83608060 92.25 -1.47914088e+00 -1.29862750e-01 1.48483066e+00 -3.05402113 0.88297982 92.50 -1.38756218e+00 -1.03032596e-01 1.39138223e+00 -3.06747428 0.78118191 92.75 -1.24858601e+00 -1.59154989e-02 1.24868745e+00 -3.12884653 0.72653800 93.00 -1.17587029e+00 -7.24009042e-02 1.17809712e+00 -3.08009810 0.60563587 93.25 -1.19981753e+00 -2.31634143e-01 1.22197237e+00 -2.95088110 0.69145593 93.50 -1.10111986e+00 -1.30744247e-01 1.10885482e+00 -3.02340847 0.59280993 93.75 -1.06535278e+00 -2.28149457e-02 1.06559705e+00 -3.12018054 0.63609433 94.00 -1.04478145e+00 -9.74779509e-02 1.04931893e+00 -3.04856212 0.60133632 94.25 -1.11697770e+00 -5.18359525e-02 1.11817984e+00 -3.09521860 0.71871451 94.50 -9.44651454e-01 -2.99609941e-02 9.45126463e-01 -3.10988683 0.60127748 94.75 -8.61899605e-01 -3.66179654e-02 8.62677115e-01 -3.09913300 0.64409663 95.00 -7.86445341e-01 1.21814743e-01 7.95823539e-01 2.98792101 0.48105644 95.25 -8.17216796e-01 2.76655517e-01 8.62775502e-01 2.81516899 0.55293042 95.50 -6.08993996e-01 2.61463520e-01 6.62749470e-01 2.73605446 0.34147634 95.75 -2.74886053e-01 3.88364778e-01 4.75804101e-01 2.18674054 0.20987341 96.00 -1.21558034e-01 2.73545125e-01 2.99338089e-01 1.98896700 0.09988569 96.25 -2.29703311e-02 1.59430504e-01 1.61076757e-01 1.71388902 0.03315859 96.50 2.89412066e-02 2.96291029e-01 2.97701138e-01 1.47342690 0.08139542 96.75 7.45225496e-02 3.79147205e-01 3.86401622e-01 1.37671730 0.15920899 97.00 5.58485791e-01 3.07078654e-01 6.37341101e-01 0.50272150 0.33405830 97.25 8.44387518e-01 1.61912169e-01 8.59770801e-01 0.18945141 0.49086820 97.50 1.33113034e+00 -1.22519841e-01 1.33675693e+00 -0.09178335 0.73159556 97.75 1.54589997e+00 -2.37707266e-01 1.56406888e+00 -0.15257129 0.79783568 98.00 1.92237171e+00 -5.20466122e-01 1.99158177e+00 -0.26440298 0.84379307 98.25 2.19769624e+00 -7.39900229e-01 2.31890515e+00 -0.32475129 0.84115794 98.50 2.62008008e+00 -1.50521048e+00 3.02166812e+00 -0.52145111 0.89880151 98.75 2.82626197e+00 -1.80092514e+00 3.35128156e+00 -0.56733209 0.90061189 99.00 3.32956066e+00 -2.67683359e+00 4.27216716e+00 -0.67715092 0.91193711 99.25 3.57249691e+00 -3.21861110e+00 4.80855400e+00 -0.73333508 0.89241691 99.50 4.49932048e+00 -4.64735605e+00 6.46852403e+00 -0.80158138 0.91033786 99.75 4.35438557e+00 -5.83520885e+00 7.28081973e+00 -0.92971485 0.85092983 100.00 3.28000739e+00 -1.00618234e+01 1.05829456e+01 -1.25567344 0.90418218 100.25 1.25864482e+00 -1.20303474e+01 1.20960094e+01 -1.46655308 0.89137212 100.50 -4.18682375e+00 -1.21276990e+01 1.28300653e+01 -1.90321379 0.92949213 100.75 -5.53287367e+00 -1.01010443e+01 1.15171084e+01 -2.07191248 0.90472941 101.00 -7.24013600e+00 -6.35249621e+00 9.63191453e+00 -2.42140491 0.94746068 101.25 -7.10708822e+00 -5.22475272e+00 8.82092648e+00 -2.50766560 0.94181024 101.50 -7.04754468e+00 -3.87726602e+00 8.04369802e+00 -2.63862783 0.96800321 101.75 -7.04717723e+00 -3.33652892e+00 7.79712332e+00 -2.69940477 0.96808615 102.00 -7.16851860e+00 -2.55967548e+00 7.61180646e+00 -2.79863178 0.96485991 102.25 -6.89500959e+00 -1.77542285e+00 7.11992160e+00 -2.88957345 0.96097537 102.50 -6.29155903e+00 -1.09239658e+00 6.38569067e+00 -2.96967764 0.97739371 102.75 -5.75249656e+00 -7.36609010e-01 5.79946631e+00 -3.01423541 0.97237825 103.00 -5.30876503e+00 -6.61260733e-01 5.34978990e+00 -3.01767074 0.98623357 103.25 -5.17719893e+00 -5.38958307e-01 5.20517674e+00 -3.03786399 0.98535729 103.50 -5.06732082e+00 -2.95832822e-01 5.07594891e+00 -3.08327832 0.99077121 103.75 -4.89427973e+00 -1.46960228e-01 4.89648562e+00 -3.11157474 0.98689171 104.00 -4.74014590e+00 3.31447074e-03 4.74014706e+00 3.14089342 0.99130222 104.25 -4.53534198e+00 1.52600545e-01 4.53790853e+00 3.10795837 0.98973415 104.50 -4.41955963e+00 2.66101614e-01 4.42756337e+00 3.08145527 0.99137817 104.75 -4.25787662e+00 5.37491727e-01 4.29166759e+00 3.01602215 0.98624320 105.00 -4.01818950e+00 7.44502199e-01 4.08657930e+00 2.95838727 0.98765853 105.25 -3.62696323e+00 7.54768129e-01 3.70466424e+00 2.93642167 0.98466649 105.50 -3.38327272e+00 7.60509175e-01 3.46769499e+00 2.92048280 0.99053700 105.75 -3.09645572e+00 6.16593536e-01 3.15724969e+00 2.94503492 0.99017958 106.00 -2.97150108e+00 5.01133499e-01 3.01346204e+00 2.97451819 0.99269002 106.25 -2.99728644e+00 3.07057265e-01 3.01297364e+00 3.03950372 0.99217071 106.50 -3.02329522e+00 1.70419247e-01 3.02809457e+00 3.08528353 0.99549315 106.75 -3.18064011e+00 1.75749876e-01 3.18549204e+00 3.08639265 0.99192806 107.00 -3.31393694e+00 2.59233537e-01 3.32406078e+00 3.06352638 0.98931872 107.25 -3.20535076e+00 5.59798996e-01 3.25386669e+00 2.96869130 0.98259695 107.50 -3.12413627e+00 6.17257316e-01 3.18453042e+00 2.94652803 0.98902927 107.75 -3.03400397e+00 6.05886837e-01 3.09390998e+00 2.94448676 0.99039748 108.00 -3.04230655e+00 6.49345438e-01 3.11083247e+00 2.93130945 0.98908107 108.25 -3.02710259e+00 8.89462443e-01 3.15507425e+00 2.85580327 0.98166993 108.50 -2.91423369e+00 9.97949159e-01 3.08036695e+00 2.81166893 0.97383413 108.75 -2.54605015e+00 1.05471171e+00 2.75586432e+00 2.74885897 0.96725501 109.00 -2.39493092e+00 1.06177089e+00 2.61974265e+00 2.72429020 0.97034602 109.25 -2.34857841e+00 8.45575273e-01 2.49616067e+00 2.79600426 0.98080429 109.50 -2.35118131e+00 8.00563387e-01 2.48373817e+00 2.81341130 0.98426957 109.75 -2.34250256e+00 7.66263705e-01 2.46464568e+00 2.82545055 0.97807175 110.00 -2.42357677e+00 7.06126908e-01 2.52434934e+00 2.85808363 0.95530654 110.25 -2.33765303e+00 1.17919866e+00 2.61823055e+00 2.67440175 0.88903699 110.50 -1.95584728e+00 1.17387783e+00 2.28108039e+00 2.60103427 0.90611341 110.75 -1.86106110e+00 9.31764259e-01 2.08128159e+00 2.67741486 0.97213986 111.00 -1.86527659e+00 9.10679043e-01 2.07571508e+00 2.68740744 0.96881911 111.25 -1.80653060e+00 9.32457466e-01 2.03298542e+00 2.66510138 0.94816146 111.50 -1.75627877e+00 9.67963693e-01 2.00536003e+00 2.63787104 0.93554747 111.75 -1.54260510e+00 1.00489398e+00 1.84104384e+00 2.56421521 0.90985229 112.00 -1.40982222e+00 8.65597734e-01 1.65434522e+00 2.59095964 0.89511944 112.25 -1.15001871e+00 6.81197060e-01 1.33662728e+00 2.60682778 0.89960986 112.50 -1.11023349e+00 5.08283108e-01 1.22105287e+00 2.71225764 0.88729514 112.75 -1.08517715e+00 2.07177516e-01 1.10477689e+00 2.95294692 0.87095339 113.00 -1.31155769e+00 2.58680719e-02 1.31181276e+00 3.12187204 0.90857239 113.25 -1.58792626e+00 2.17849861e-03 1.58792775e+00 3.14022074 0.96946971 113.50 -1.71403293e+00 8.00074678e-02 1.71589920e+00 3.09494860 0.97984583 113.75 -1.80626282e+00 1.47233144e-01 1.81225356e+00 3.06025989 0.98716019 114.00 -1.80445343e+00 2.43765105e-01 1.82084420e+00 3.00731473 0.98493381 114.25 -1.80284604e+00 2.88984111e-01 1.82586025e+00 2.98265144 0.99210201 114.50 -1.79712742e+00 3.09950742e-01 1.82366018e+00 2.97080276 0.98822441 114.75 -1.79002302e+00 3.30799011e-01 1.82033250e+00 2.95885279 0.98603247 115.00 -1.75872608e+00 3.74530374e-01 1.79816307e+00 2.93177149 0.97783554 115.25 -1.77198970e+00 4.19031931e-01 1.82086113e+00 2.90938299 0.98013284 115.50 -1.78889750e+00 5.00966603e-01 1.85771952e+00 2.86854492 0.97698899 115.75 -1.74829651e+00 5.84870433e-01 1.84353306e+00 2.81875890 0.97495219 116.00 -1.57150841e+00 5.37622893e-01 1.66092656e+00 2.81196734 0.96768840 116.25 -1.52606010e+00 4.62728386e-01 1.59467144e+00 2.84718649 0.97602749 116.50 -1.51253503e+00 4.29944854e-01 1.57245502e+00 2.86464315 0.97067044 116.75 -1.50988617e+00 3.73322211e-01 1.55535388e+00 2.89920211 0.97573934 117.00 -1.65475673e+00 2.25343158e-01 1.67002975e+00 3.00624619 0.96806814 117.25 -1.75988215e+00 2.54832727e-01 1.77823646e+00 2.99779112 0.97685834 117.50 -1.80635651e+00 3.86650724e-01 1.84727438e+00 2.93072464 0.97582997 117.75 -1.81929870e+00 4.73337599e-01 1.87986602e+00 2.88705988 0.97358482 118.00 -1.85185321e+00 5.61325234e-01 1.93505719e+00 2.84728015 0.97609249 118.25 -1.87679211e+00 6.76613574e-01 1.99503247e+00 2.79558035 0.97698403 118.50 -1.75857017e+00 1.00874994e+00 2.02734937e+00 2.62079656 0.95899539 118.75 -1.56273176e+00 1.07508327e+00 1.89682223e+00 2.53899895 0.94926303 119.00 -1.22714610e+00 7.56430060e-01 1.44155263e+00 2.58919137 0.93172705 119.25 -1.22479234e+00 6.10588751e-01 1.36855211e+00 2.67912630 0.94835592 119.50 -1.28209937e+00 4.93442287e-01 1.37377731e+00 2.77419656 0.95366376 119.75 -1.34973345e+00 4.85008584e-01 1.43422931e+00 2.79662451 0.96741694 120.00 -1.39795193e+00 4.87491464e-01 1.48051259e+00 2.80606009 0.96387516 120.25 -1.46687337e+00 5.33808730e-01 1.56098342e+00 2.79258069 0.95789986 120.50 -1.51793311e+00 6.54134301e-01 1.65288010e+00 2.73470366 0.96875231 120.75 -1.50913499e+00 6.99786076e-01 1.66348699e+00 2.70740429 0.96064818 121.00 -1.43118690e+00 8.08906405e-01 1.64396640e+00 2.62715475 0.95655993 121.25 -1.35828442e+00 7.26489343e-01 1.54036468e+00 2.65044902 0.93811697 121.50 -1.32967969e+00 5.68043987e-01 1.44593293e+00 2.73785700 0.95281200 121.75 -1.50431297e+00 5.27233030e-01 1.59403017e+00 2.80448944 0.93919225 122.00 -1.83153721e+00 7.64246482e-01 1.98459095e+00 2.74628712 0.94749326 122.25 -1.86215182e+00 1.05904121e+00 2.14223660e+00 2.62449149 0.89610784 122.50 -1.77542229e+00 1.82423294e+00 2.54557462e+00 2.34263551 0.90220606 122.75 -1.28650594e+00 2.09600467e+00 2.45933591e+00 2.12129361 0.82517300 123.00 -4.70522938e-02 2.97065357e+00 2.97102617e+00 1.58663404 0.85449901 123.25 8.63133171e-01 2.55944610e+00 2.70106705e+00 1.24553897 0.81487900 123.50 1.33289915e+00 9.58793316e-01 1.64192106e+00 0.62358115 0.61938280 123.75 5.47527594e-01 4.66636208e-01 7.19399622e-01 0.70580501 0.37147559 124.00 1.32792322e-02 3.05373046e-01 3.05661635e-01 1.52733843 0.32655311 124.25 -6.37710270e-02 2.82725416e-01 2.89828233e-01 1.79264198 0.34470658 124.50 -4.81236228e-02 2.90330430e-01 2.94291763e-01 1.73505752 0.58242992 124.75 -5.15618485e-02 2.58709226e-01 2.63797437e-01 1.76752281 0.53332053 125.00 -8.75142898e-02 1.99414018e-01 2.17772132e-01 1.98434541 0.48928292 125.25 -1.74286093e-01 1.39443236e-01 2.23204073e-01 2.46680147 0.46882456 125.50 -2.13168274e-01 9.19271167e-02 2.32145015e-01 2.73444686 0.66031337 125.75 -2.10155764e-01 4.67002165e-02 2.15282036e-01 2.92292853 0.59243687 126.00 -2.20385404e-01 9.69529167e-03 2.20598561e-01 3.09762856 0.64533743 126.25 -2.57600414e-01 -6.02520251e-02 2.64552981e-01 -2.91182600 0.68410449 126.50 -2.83055925e-01 -1.00778816e-01 3.00461356e-01 -2.79954846 0.80488064 126.75 -3.38931617e-01 -1.34208579e-01 3.64536122e-01 -2.76456058 0.81380135 127.00 -3.98162780e-01 -9.71699855e-02 4.09848272e-01 -2.90222567 0.84571714 127.25 -4.02417215e-01 -2.69303995e-03 4.02426226e-01 -3.13490059 0.80630839 127.50 -3.60227409e-01 1.50685385e-02 3.60542435e-01 3.09978640 0.76623519 127.75 -3.24455507e-01 -2.66259848e-02 3.25546186e-01 -3.05971254 0.67510083 128.00 -2.98063387e-01 -3.44497751e-02 3.00047613e-01 -3.02652453 0.64024983 128.25 -1.92080734e-01 -6.89101133e-02 2.04067666e-01 -2.79713880 0.43451211 128.50 -9.42214888e-02 -7.87961287e-02 1.22827191e-01 -2.44511424 0.20955035 128.75 8.44362074e-02 -1.26361866e-01 1.51976295e-01 -0.98172633 0.18016603 129.00 1.64673436e-01 -2.53186878e-01 3.02028037e-01 -0.99413805 0.32201823 129.25 -1.26232205e-02 -6.65346623e-01 6.65466358e-01 -1.58976645 0.76938551 129.50 -1.15520850e-01 -7.71620536e-01 7.80220045e-01 -1.71940460 0.85622625 129.75 -2.58795559e-01 -9.63629519e-01 9.97776023e-01 -1.83316863 0.90295158 130.00 -3.74865077e-01 -1.07921292e+00 1.14246416e+00 -1.90510878 0.93056961 130.25 -6.73675409e-01 -1.22765567e+00 1.40034889e+00 -2.07267894 0.94959780 130.50 -8.76833663e-01 -1.12812049e+00 1.42880828e+00 -2.23151168 0.92662609 130.75 -1.35771694e+00 -7.92258848e-01 1.57196354e+00 -2.61337682 0.95210010 131.00 -1.36865978e+00 -5.41335970e-01 1.47182683e+00 -2.76495199 0.93884457 131.25 -1.05778794e+00 -1.02362070e-01 1.06272919e+00 -3.04512310 0.92489182 131.50 -8.92674061e-01 -1.45721545e-01 9.04489772e-01 -2.97977831 0.93908401 131.75 -7.65256661e-01 -2.59915226e-01 8.08191612e-01 -2.81417283 0.95857187 132.00 -7.76128435e-01 -2.98540532e-01 8.31565870e-01 -2.77438560 0.95012883 132.25 -8.54403612e-01 -3.45697856e-01 9.21690045e-01 -2.75712087 0.94461016 132.50 -8.67416679e-01 -2.21523515e-01 8.95256590e-01 -2.89155404 0.91553430 132.75 -7.40170108e-01 -1.87522698e-01 7.63555205e-01 -2.89346278 0.90764686 133.00 -7.10925061e-01 -2.03895438e-01 7.39586230e-01 -2.86228674 0.92488927 133.25 -6.43181219e-01 -1.32261131e-01 6.56639237e-01 -2.93878391 0.94601447 133.50 -5.85139336e-01 -1.59010176e-01 6.06359860e-01 -2.87625273 0.92508232 133.75 -5.30482430e-01 -2.13795385e-01 5.71944119e-01 -2.75848497 0.93387634 134.00 -4.40283742e-01 -2.26724577e-01 4.95231064e-01 -2.66605587 0.75497604 134.25 -2.34815709e-01 -3.49365450e-01 4.20944931e-01 -2.16256522 0.67066950 134.50 -2.52243754e-01 -4.97115418e-01 5.57450132e-01 -2.04035822 0.87178637 134.75 -2.47788038e-01 -5.37028516e-01 5.91437688e-01 -2.00309468 0.95212084 135.00 -2.08816629e-01 -6.16321790e-01 6.50735686e-01 -1.89746869 0.93424707 135.25 -1.91859535e-01 -7.58578087e-01 7.82464565e-01 -1.81852129 0.94713020 135.50 -2.56338195e-01 -8.92536593e-01 9.28617704e-01 -1.85047078 0.96472032 135.75 -3.45160268e-01 -9.77404012e-01 1.03655883e+00 -1.91026556 0.97907126 136.00 -3.99919632e-01 -9.75449101e-01 1.05424696e+00 -1.95988083 0.98618119 136.25 -4.18414209e-01 -9.80253848e-01 1.06581802e+00 -1.97422673 0.98791387 136.50 -3.36935756e-01 -1.05798382e+00 1.11034025e+00 -1.87911047 0.97771856 136.75 -2.87791412e-01 -1.14320202e+00 1.17887012e+00 -1.81741339 0.97705768 137.00 -2.99535664e-01 -1.40825902e+00 1.43976216e+00 -1.78037237 0.96769114 137.25 -3.40905614e-01 -1.62707262e+00 1.66240247e+00 -1.77732955 0.96730214 137.50 -5.94999586e-01 -1.86468827e+00 1.95731624e+00 -1.87967174 0.95685376 137.75 -8.27670794e-01 -1.97581573e+00 2.14216870e+00 -1.96748958 0.96324361 138.00 -1.22945228e+00 -1.94842373e+00 2.30388974e+00 -2.13369748 0.94033164 138.25 -1.52995813e+00 -1.85770043e+00 2.40662061e+00 -2.25974868 0.94817982 138.50 -1.85847463e+00 -1.52538817e+00 2.40431633e+00 -2.45431221 0.93606405 138.75 -2.02801108e+00 -1.36818146e+00 2.44637476e+00 -2.54808897 0.94518219 139.00 -1.88421946e+00 -9.83112778e-01 2.12527498e+00 -2.66068796 0.92484638 139.25 -1.80607396e+00 -8.59922551e-01 2.00034246e+00 -2.69722430 0.94866135 139.50 -1.58647326e+00 -8.33840675e-01 1.79225770e+00 -2.65768019 0.92786885 139.75 -1.44763966e+00 -8.20168269e-01 1.66383190e+00 -2.62612777 0.92426783 140.00 -1.42783541e+00 -1.09298946e+00 1.79814903e+00 -2.48825331 0.93277058 140.25 -1.39512479e+00 -1.26865965e+00 1.88570159e+00 -2.40363461 0.92786057 140.50 -1.49348327e+00 -1.75735099e+00 2.30624690e+00 -2.27520282 0.95616960 140.75 -1.63994280e+00 -1.97099472e+00 2.56402663e+00 -2.26476975 0.93823628 141.00 -2.64502487e+00 -2.35731945e+00 3.54303705e+00 -2.41364532 0.95377836 141.25 -3.06507278e+00 -2.18677862e+00 3.76519214e+00 -2.52189624 0.96727312 141.50 -3.59956181e+00 -1.37328401e+00 3.85262952e+00 -2.77712316 0.96256702 141.75 -3.57089426e+00 -9.10503992e-01 3.68514631e+00 -2.89193314 0.95939721 142.00 -3.19159860e+00 -2.47725922e-01 3.20119818e+00 -3.06412983 0.96806438 142.25 -3.09399327e+00 -1.44419026e-01 3.09736197e+00 -3.09494928 0.97810599 142.50 -3.00010759e+00 -5.54815872e-03 3.00011272e+00 -3.13974334 0.98507057 142.75 -2.94496002e+00 3.14821258e-02 2.94512829e+00 3.13090289 0.98094177 143.00 -2.88109438e+00 1.66933747e-01 2.88592649e+00 3.08371627 0.98343104 143.25 -2.83598952e+00 1.78357705e-01 2.84159252e+00 3.07878455 0.98288076 143.50 -2.78711899e+00 2.11380416e-01 2.79512324e+00 3.06589566 0.98808595 143.75 -2.82148188e+00 2.87985579e-01 2.83614099e+00 3.03987600 0.98650753 144.00 -2.87192706e+00 3.76191370e-01 2.89646077e+00 3.01134503 0.98485485 144.25 -2.86883276e+00 4.42645498e-01 2.90278081e+00 2.98850524 0.97612166 144.50 -2.87514124e+00 6.13875131e-01 2.93994555e+00 2.93123986 0.97776297 144.75 -2.96090610e+00 7.02684347e-01 3.04314479e+00 2.90858257 0.96570939 145.00 -3.22016474e+00 8.62108939e-01 3.33357057e+00 2.88000525 0.96863582 145.25 -3.34077639e+00 1.19166196e+00 3.54694871e+00 2.79895966 0.95971050 145.50 -3.49396967e+00 1.35016623e+00 3.74576733e+00 2.77284112 0.96601680 145.75 -3.64930871e+00 1.75770957e+00 4.05055515e+00 2.69272806 0.93156847 146.00 -3.81799406e+00 2.63311799e+00 4.63792938e+00 2.53784001 0.92978473 146.25 -3.55390778e+00 3.57665945e+00 5.04209810e+00 2.35300378 0.90007234 146.50 -2.73021234e+00 4.42206140e+00 5.19698821e+00 2.12391698 0.90420568 146.75 -1.47005953e+00 5.14764247e+00 5.35343797e+00 1.84897108 0.88400275 147.00 -4.70537469e-02 5.15533037e+00 5.15554510e+00 1.57992328 0.86212702 147.25 1.23483836e+00 3.93651340e+00 4.12564705e+00 1.26682921 0.79058994 147.50 1.83627519e+00 2.88083231e+00 3.41629937e+00 1.00332174 0.74981488 147.75 1.74691430e+00 1.71959012e+00 2.45126493e+00 0.77751598 0.70205667 148.00 1.49210287e+00 1.27674003e+00 1.96378107e+00 0.70777364 0.69974022 148.25 1.07721515e+00 5.40737381e-01 1.20531713e+00 0.46522807 0.46279371 148.50 7.48251802e-01 3.34082565e-01 8.19446105e-01 0.41992629 0.38461965 148.75 4.69883347e-01 3.62291525e-01 5.93334230e-01 0.65682150 0.22068894 149.00 3.37965001e-01 2.91750557e-01 4.46473660e-01 0.71214010 0.12889177 149.25 2.63150757e-01 2.28241757e-01 3.48342677e-01 0.71447634 0.08488147 149.50 1.66602588e-01 1.37449825e-01 2.15983510e-01 0.68980965 0.05069215 149.75 1.71181831e-01 1.36741571e-01 2.19092393e-01 0.67401424 0.05055803 150.00 1.58513115e-01 2.64045648e-01 3.07971609e-01 1.03013814 0.09146328 150.25 1.68017307e-01 3.74282422e-01 4.10264727e-01 1.14885325 0.21146983 150.50 4.36197361e-02 3.61524993e-01 3.64146951e-01 1.45072192 0.18234064 150.75 3.56350678e-02 3.47523822e-01 3.49346053e-01 1.46861353 0.16891221 151.00 8.44904208e-02 2.28995895e-01 2.44085541e-01 1.21733112 0.08375434 151.25 1.74171163e-01 5.02091670e-02 1.81263771e-01 0.28066537 0.08643983 151.50 9.49936947e-02 9.06685943e-02 1.31318681e-01 0.76210685 0.05531026 151.75 -1.09730967e-01 2.01699747e-01 2.29616360e-01 2.06904546 0.12614640 152.00 -1.71442843e-01 2.53113059e-01 3.05710433e-01 2.16614976 0.22058867 152.25 -1.61205534e-01 2.15550683e-01 2.69164116e-01 2.21293773 0.14852037 152.50 -1.51293755e-01 8.83613637e-02 1.75207108e-01 2.61299230 0.05294434 152.75 -2.49153964e-01 -3.61406368e-02 2.51761482e-01 -2.99754390 0.09608856 153.00 -3.43785529e-01 5.95414895e-02 3.48903538e-01 2.97010014 0.14471240 153.25 -4.50250988e-01 1.94998826e-01 4.90663321e-01 2.73289041 0.29365018 153.50 -3.17668582e-01 2.08769867e-01 3.80129170e-01 2.56017679 0.21471153 153.75 -3.50127619e-01 2.82527068e-01 4.49900983e-01 2.46264280 0.32619009 154.00 -3.69777067e-01 3.22990098e-01 4.90976255e-01 2.42362844 0.49927863 154.25 -3.45798560e-01 5.20200204e-01 6.24647817e-01 2.15746480 0.49230116 154.50 -4.54965311e-01 6.25519679e-01 7.73478056e-01 2.19963643 0.51171559 154.75 -2.08465848e-01 7.14582628e-01 7.44369761e-01 1.85464965 0.33072183 155.00 -1.67587277e-03 6.58235274e-01 6.58237408e-01 1.57334233 0.22681824 155.25 1.85136372e-01 5.46881403e-01 5.77368813e-01 1.24437508 0.20202528 155.50 2.87510206e-01 4.02846309e-01 4.94921476e-01 0.95093677 0.16584478 155.75 6.16569424e-01 3.97351324e-01 7.33516141e-01 0.57246736 0.35034631 156.00 6.35209975e-01 3.74009248e-01 7.37139492e-01 0.53214071 0.37365836 156.25 6.55650101e-01 3.43799708e-01 7.40321075e-01 0.48294877 0.37789408 156.50 7.89489179e-01 2.55919598e-02 7.89903863e-01 0.03240450 0.22445173 156.75 7.43802434e-01 -7.95546795e-01 1.08909906e+00 -0.81899995 0.39696747 157.00 6.81380719e-01 -8.49610475e-01 1.08909028e+00 -0.89484199 0.42027865 157.25 6.97425164e-01 -1.17979958e+00 1.37052140e+00 -1.03691798 0.55986070 157.50 4.57748774e-01 -1.52559958e+00 1.59279252e+00 -1.27929810 0.53083212 157.75 3.52449333e-01 -1.84759903e+00 1.88091539e+00 -1.38230026 0.58216373 158.00 -3.62625727e-01 -2.05911989e+00 2.09080658e+00 -1.74511604 0.43262315 158.25 -1.17858935e+00 -2.18099849e+00 2.47907791e+00 -2.06623134 0.38733413 158.50 -2.77808587e+00 -5.42929642e-01 2.83064192e+00 -2.94859228 0.33417947 158.75 -3.13776065e+00 6.66295962e-01 3.20772384e+00 2.93235307 0.46284364 159.00 -1.74784247e+00 1.56476926e+00 2.34594462e+00 2.41140385 0.44510983 159.25 -1.09669896e+00 1.29439429e+00 1.69652740e+00 2.27370223 0.46648656 159.50 -5.82686024e-01 1.19012097e+00 1.32510789e+00 2.02609127 0.44633509 159.75 -3.91788270e-01 1.11742074e+00 1.18411451e+00 1.90802195 0.48741155 160.00 -8.54122885e-01 1.09289805e+00 1.38706598e+00 2.23416765 0.67076186 160.25 -1.08217992e+00 1.24645373e+00 1.65068479e+00 2.28576601 0.76935115 160.50 -1.32030679e+00 1.70527814e+00 2.15666028e+00 2.22963590 0.80508693 160.75 -1.49355892e+00 1.80556374e+00 2.34324106e+00 2.26190287 0.85368748 161.00 -1.44933693e+00 1.78290458e+00 2.29767845e+00 2.25335843 0.84527042 161.25 -1.53460642e+00 1.84807819e+00 2.40216775e+00 2.26378888 0.85636709 161.50 -1.89024305e+00 2.08068784e+00 2.81109955e+00 2.30827148 0.82881147 161.75 -2.32976444e+00 2.02628602e+00 3.08765888e+00 2.42575035 0.81834746 162.00 -2.86671575e+00 1.59700485e+00 3.28153678e+00 2.63332605 0.84908059 162.25 -3.19017243e+00 1.55936017e+00 3.55088781e+00 2.68694414 0.79776795 162.50 -4.24958594e+00 1.59817209e+00 4.54016902e+00 2.78187798 0.81061280 162.75 -4.84205567e+00 1.69549220e+00 5.13032133e+00 2.80477567 0.76417930 163.00 -6.08492507e+00 2.18254597e+00 6.46450463e+00 2.79720538 0.71064839 163.25 -5.86559568e+00 3.15668777e+00 6.66107277e+00 2.64787730 0.62800661 163.50 -3.81953978e+00 5.37738169e+00 6.59584096e+00 2.18839986 0.54231721 163.75 -2.11270715e+00 5.64411822e+00 6.02657465e+00 1.92897083 0.47988110 164.00 -1.67875854e+00 4.93078293e+00 5.20872830e+00 1.89895151 0.62039885 164.25 -1.19421876e+00 3.77106767e+00 3.95564278e+00 1.87748405 0.58334879 164.50 -1.05281686e+00 3.50093497e+00 3.65581304e+00 1.86291765 0.69805212 164.75 -8.52293807e-01 2.87506587e+00 2.99873448e+00 1.85898684 0.68048253 165.00 -1.50807385e+00 2.80531628e+00 3.18497820e+00 2.06405182 0.83202414 165.25 -1.62943392e+00 2.68005503e+00 3.13651875e+00 2.11706665 0.83441229 165.50 -1.92540225e+00 2.36538941e+00 3.04995752e+00 2.25400946 0.89311562 165.75 -2.03949149e+00 2.09801519e+00 2.92595169e+00 2.34205076 0.86046876 166.00 -2.26399070e+00 1.79794289e+00 2.89106426e+00 2.47043042 0.91308315 166.25 -2.37955590e+00 1.52868405e+00 2.82827884e+00 2.57056165 0.89606986 166.50 -2.51519492e+00 1.26365373e+00 2.81478707e+00 2.67602060 0.91282921 166.75 -2.74343290e+00 8.70002455e-01 2.87807720e+00 2.83450271 0.87957078 167.00 -2.91924767e+00 4.63017477e-01 2.95573885e+00 2.98429446 0.86516050 167.25 -3.38202270e+00 1.94821789e-01 3.38762942e+00 3.08405114 0.80414297 167.50 -3.80779393e+00 -1.17588377e-01 3.80960911e+00 -3.11072149 0.73745485 167.75 -4.99448925e+00 3.80390485e-01 5.00895396e+00 3.06557737 0.65170297 168.00 -6.12997056e+00 1.46628747e+00 6.30289918e+00 2.90680447 0.78385921 168.25 -6.37753396e+00 2.85665207e+00 6.98808990e+00 2.72046627 0.84132612 168.50 -6.76834051e+00 3.13924036e+00 7.46091571e+00 2.70731187 0.87425457 168.75 -7.58594925e+00 3.33406812e+00 8.28629207e+00 2.72749996 0.86029407 169.00 -8.62950991e+00 3.86175343e+00 9.45418325e+00 2.72081506 0.87822593 169.25 -9.16382084e+00 7.01313843e+00 1.15394854e+01 2.48836667 0.72667993 169.50 -6.27819476e+00 1.12387362e+01 1.28734192e+01 2.08023429 0.70725074 169.75 2.48475068e+00 1.42031405e+01 1.44188483e+01 1.39760524 0.80467313 170.00 6.19081746e+00 1.31258935e+01 1.45125911e+01 1.13008547 0.86397604 170.25 6.82957297e+00 6.77596748e+00 9.62064459e+00 0.78145821 0.83473663 170.50 6.48417415e+00 4.27067181e+00 7.76422257e+00 0.58241812 0.87950968 170.75 4.60025327e+00 2.46408370e+00 5.21862420e+00 0.49175214 0.89908393 171.00 4.07055643e+00 1.85187610e+00 4.47201014e+00 0.42695792 0.92346760 171.25 2.77224938e+00 7.26694059e-01 2.86591187e+00 0.25636361 0.77425219 171.50 2.21918929e+00 1.12819474e-01 2.22205520e+00 0.05079442 0.70072183 171.75 9.33339024e-01 -2.65989728e-01 9.70501040e-01 -0.27762737 0.17043040 172.00 1.10464983e-01 -3.12615738e-01 3.31558610e-01 -1.23113393 0.02193092 172.25 -1.97637657e-01 -3.76973610e-01 4.25640395e-01 -2.05367443 0.01354271 172.50 1.08264811e+00 6.28106617e-01 1.25165685e+00 0.52570177 0.07432839 172.75 1.92460819e+00 1.91406897e+00 2.71436488e+00 0.78265264 0.53497733 173.00 1.21428638e+00 2.05759075e+00 2.38917792e+00 1.03765124 0.56703760 173.25 7.90552199e-01 1.94973249e+00 2.10390816e+00 1.18558591 0.59755829 173.50 3.32350381e-01 1.95930973e+00 1.98729751e+00 1.40276944 0.55715803 173.75 4.78363393e-02 1.47727932e+00 1.47805362e+00 1.53842626 0.46905249 174.00 5.72892568e-01 8.84732229e-01 1.05401945e+00 0.99615793 0.19446285 174.25 2.37457283e+00 1.09836769e+00 2.61629656e+00 0.43324449 0.63138942 174.50 2.26737668e+00 1.48289082e+00 2.70923646e+00 0.57919021 0.78122395 174.75 1.98457940e+00 1.66412101e+00 2.58995254e+00 0.69779486 0.87874586 175.00 1.87039460e+00 1.70057719e+00 2.52791193e+00 0.73787900 0.89311887 175.25 1.80711606e+00 1.71505555e+00 2.49140201e+00 0.75926668 0.92762498 175.50 1.77252248e+00 1.65317687e+00 2.42380481e+00 0.75057393 0.91189725 175.75 1.84596258e+00 1.54407834e+00 2.40660669e+00 0.69658211 0.90363454 176.00 2.01802435e+00 1.22078119e+00 2.35854383e+00 0.54404305 0.89997186 176.25 2.11473915e+00 9.34745037e-01 2.31211374e+00 0.41619324 0.92390917 176.50 1.87470906e+00 7.16595969e-01 2.00699871e+00 0.36510625 0.91134753 176.75 1.73434541e+00 5.48933932e-01 1.81914334e+00 0.30653197 0.95313012 177.00 1.63106122e+00 4.75245458e-01 1.69888756e+00 0.28352246 0.94652605 177.25 1.52051723e+00 4.01558861e-01 1.57264814e+00 0.25819861 0.95144067 177.50 1.49480627e+00 3.37094659e-01 1.53234415e+00 0.22180038 0.94727609 177.75 1.52065415e+00 2.86674297e-01 1.54744021e+00 0.18633349 0.95458498 178.00 1.43374506e+00 1.16192727e-01 1.43844557e+00 0.08086469 0.91104115 178.25 1.37361783e+00 8.33607872e-03 1.37364313e+00 0.00606863 0.92626641 178.50 1.52900812e+00 -9.25375967e-02 1.53180581e+00 -0.06044759 0.86416121 178.75 1.80347761e+00 -3.17863307e-01 1.83127512e+00 -0.17445847 0.83065410 179.00 1.60729716e+00 -1.30111038e+00 2.06791982e+00 -0.68050809 0.72428195 179.25 9.98478170e-01 -2.06787265e+00 2.29631356e+00 -1.12096031 0.73064855 179.50 -1.14366625e-01 -2.05779331e+00 2.06096896e+00 -1.62631652 0.74171210 179.75 -7.21931103e-01 -1.66796503e+00 1.81749604e+00 -1.97927315 0.75366722 180.00 -1.16096120e+00 -9.31561808e-01 1.48850203e+00 -2.46538658 0.68730390 180.25 -1.30584063e+00 -6.47913011e-01 1.45774175e+00 -2.68101738 0.74287296 180.50 -1.21106320e+00 -6.45968031e-03 1.21108043e+00 -3.13625881 0.61232720 180.75 -1.01747203e+00 2.21498218e-01 1.04130245e+00 2.92724233 0.63557919 181.00 -7.85351235e-01 4.88749706e-01 9.25015047e-01 2.58491374 0.58985036 181.25 -7.02300968e-01 5.70667768e-01 9.04924500e-01 2.45923473 0.64646899 181.50 -4.05100907e-01 5.78150545e-01 7.05949572e-01 2.18198129 0.62943167 181.75 -4.53608528e-01 5.72697484e-01 7.30577241e-01 2.24067461 0.64300101 182.00 -4.36156061e-01 7.71649856e-01 8.86383444e-01 2.08525367 0.65326660 182.25 -3.14250092e-01 8.35227723e-01 8.92389191e-01 1.93065789 0.67400272 182.50 -1.83542405e-01 8.09894546e-01 8.30431809e-01 1.79365699 0.65034727 182.75 -1.23494236e-02 8.20347855e-01 8.20440803e-01 1.58584908 0.61424320 183.00 1.37729758e-01 8.53705447e-01 8.64744168e-01 1.41084287 0.68745644 183.25 2.01346379e-01 7.77643035e-01 8.03286409e-01 1.31744130 0.62724027 183.50 2.37950140e-01 5.75074291e-01 6.22358988e-01 1.17847346 0.53122643 183.75 3.01544228e-01 4.84530557e-01 5.70700256e-01 1.01410991 0.49418116 184.00 3.94833462e-01 4.13059047e-01 5.71411619e-01 0.80795376 0.56033823 184.25 3.65337841e-01 3.65690519e-01 5.16915171e-01 0.78588060 0.46905142 184.50 3.60022109e-01 3.21598222e-01 4.82743551e-01 0.72908637 0.43945419 184.75 3.95671113e-01 2.99827709e-01 4.96439608e-01 0.64845541 0.42357165 185.00 4.96041678e-01 1.98897972e-01 5.34432175e-01 0.38134255 0.51054490 185.25 4.59723452e-01 7.24927162e-02 4.65403960e-01 0.15639983 0.35766629 185.50 2.09734632e-01 -3.98936941e-01 4.50709773e-01 -1.08677426 0.37120775 185.75 -6.17219578e-02 -3.14457818e-01 3.20457984e-01 -1.76461296 0.20681727 186.00 -2.55167375e-01 1.95939572e-02 2.55918566e-01 3.06495440 0.20657045 186.25 -2.17860420e-01 1.37806433e-01 2.57786298e-01 2.57758639 0.18249731 186.50 -2.02176369e-01 2.78963932e-01 3.44523090e-01 2.19793419 0.33189619 186.75 -1.35265051e-01 2.65449586e-01 2.97926361e-01 2.04207031 0.23775623 187.00 -7.90694103e-02 2.90512886e-01 3.01080901e-01 1.83653127 0.37135732 187.25 2.18115649e-02 3.61544762e-01 3.62202097e-01 1.51054055 0.41728114 187.50 8.63765569e-02 4.23698467e-01 4.32413344e-01 1.36968885 0.63791918 187.75 1.49939079e-01 4.20133925e-01 4.46087707e-01 1.22800197 0.58497750 188.00 1.88121543e-01 3.97679734e-01 4.39930546e-01 1.12894197 0.66945453 188.25 1.59502972e-01 3.92625522e-01 4.23787681e-01 1.18491616 0.63279681 188.50 1.52597462e-01 4.09826053e-01 4.37313822e-01 1.21435368 0.69722128 188.75 1.91736664e-01 3.46520478e-01 3.96029532e-01 1.06540785 0.48069105 189.00 1.76198971e-01 2.58738796e-01 3.13036487e-01 0.97294185 0.34335539 189.25 3.61972803e-02 3.03106344e-01 3.05260052e-01 1.45193816 0.25565770 189.50 -2.42180045e-02 3.41798815e-01 3.42655719e-01 1.64153267 0.31887620 189.75 -6.64452117e-02 3.53379611e-01 3.59572128e-01 1.75665416 0.30126252 190.00 -5.02147277e-02 4.14330211e-01 4.17362004e-01 1.69140307 0.44373683 190.25 -8.51239929e-02 5.40826419e-01 5.47484529e-01 1.72691170 0.51047788 190.50 -5.81130426e-02 6.07948103e-01 6.10719266e-01 1.66609560 0.61443359 190.75 3.30084093e-02 6.52151889e-01 6.52986708e-01 1.52022488 0.68508577 191.00 1.01746464e-01 6.68864474e-01 6.76558961e-01 1.41983543 0.75523413 191.25 2.41901447e-01 5.50435211e-01 6.01244735e-01 1.15673101 0.60153515 191.50 3.81083513e-01 3.87412737e-01 5.43427339e-01 0.79363383 0.49401925 191.75 3.13141128e-01 -1.57829748e-01 3.50667357e-01 -0.46685934 0.24181600 192.00 1.34103004e-01 -3.00061068e-01 3.28664358e-01 -1.15050748 0.23324931 192.25 -2.26950298e-01 -3.14115209e-01 3.87523938e-01 -2.19646821 0.33034131 192.50 -3.39795453e-01 -2.63462139e-01 4.29968893e-01 -2.48206077 0.35756217 192.75 -5.99557738e-01 -1.31619509e-01 6.13834812e-01 -2.92549292 0.41278825 193.00 -5.84141921e-01 -5.94679138e-02 5.87161150e-01 -3.04013830 0.36485717 193.25 -5.04680690e-01 5.86691250e-02 5.08079388e-01 3.02586213 0.37247576 193.50 -4.23126274e-01 6.59921386e-02 4.28241528e-01 2.98687586 0.29722529 193.75 -3.93672893e-01 3.44658541e-02 3.95178747e-01 3.05426584 0.32924420 194.00 -3.42199827e-01 -2.67924130e-03 3.42210315e-01 -3.13376335 0.25864382 194.25 -1.81240662e-01 -5.64077021e-02 1.89815717e-01 -2.83986436 0.12966356 194.50 -2.58250879e-01 -8.91282135e-02 2.73198381e-01 -2.80926955 0.22597216 194.75 -3.05617698e-01 -9.73462127e-02 3.20746726e-01 -2.83323025 0.26028737 195.00 -3.29835213e-01 -9.84681222e-02 3.44219754e-01 -2.85147830 0.22120434 195.25 -1.09238778e-01 -2.09109084e-01 2.35923122e-01 -2.05220365 0.16596450 195.50 -6.03990013e-02 -2.60236429e-01 2.67153585e-01 -1.79885146 0.23261945 195.75 -2.21379724e-02 -3.23345430e-01 3.24102386e-01 -1.63915504 0.35671472 196.00 -5.50377742e-02 -4.73006922e-01 4.76198178e-01 -1.68663266 0.40320127 196.25 3.65549118e-02 -8.40430437e-01 8.41225048e-01 -1.52732826 0.66951482 196.50 -6.81549571e-02 -1.02711696e+00 1.02937570e+00 -1.63705479 0.72411771 196.75 -2.25956604e-01 -1.19472377e+00 1.21590348e+00 -1.75771724 0.81344256 197.00 -5.88692846e-01 -1.23648016e+00 1.36946794e+00 -2.01514484 0.81207954 197.25 -8.29143648e-01 -1.38901900e+00 1.61766899e+00 -2.10895358 0.92354847 197.50 -8.90545376e-01 -1.39414259e+00 1.65429883e+00 -2.13924098 0.87013481 197.75 -1.20566460e+00 -1.52739350e+00 1.94590803e+00 -2.23901622 0.83445065 198.00 -2.04466383e+00 -1.42615065e+00 2.49290110e+00 -2.53254729 0.82459646 198.25 -2.59956149e+00 -1.13839763e+00 2.83789871e+00 -2.72883050 0.91234770 198.50 -2.67401688e+00 -4.97189677e-01 2.71984630e+00 -2.95775830 0.86870174 198.75 -2.76020417e+00 1.56535826e-01 2.76463931e+00 3.08494165 0.89352372 199.00 -2.36738229e+00 8.01626262e-01 2.49942065e+00 2.81509801 0.82975720 199.25 -1.92126120e+00 1.30334305e+00 2.32162609e+00 2.54552535 0.83215689 199.50 -1.33022384e+00 1.10511366e+00 1.72938476e+00 2.44836747 0.73404895 199.75 -1.02756928e+00 9.82030701e-01 1.42136657e+00 2.37885113 0.78852334 200.00 -9.45443515e-01 9.59073197e-01 1.34673117e+00 2.34903811 0.77860019 200.25 -7.31566777e-01 9.46779465e-01 1.19648707e+00 2.22866143 0.72086313 200.50 -5.48720622e-01 5.99452163e-01 8.12672884e-01 2.31203862 0.48795257 200.75 -5.09841739e-01 4.87366039e-01 7.05311459e-01 2.37872931 0.47171651 201.00 -4.50872161e-01 2.86633139e-01 5.34269840e-01 2.57531428 0.20297476 201.25 -4.99078325e-01 1.85427481e-01 5.32411988e-01 2.78585899 0.22375410 201.50 -6.37817367e-01 2.81470206e-01 6.97163159e-01 2.72599532 0.27967576 201.75 -5.41840767e-01 4.26398417e-01 6.89497663e-01 2.47486346 0.32219760 202.00 -5.21981119e-01 2.73301909e-01 5.89201342e-01 2.65925492 0.27974069 202.25 -4.73395928e-01 2.64997199e-01 5.42519326e-01 2.63127243 0.26060469 202.50 -6.16831256e-01 1.11211839e-01 6.26776572e-01 2.96321360 0.33190527 202.75 -6.08364607e-01 1.18798519e-01 6.19855292e-01 2.94874427 0.37778212 203.00 -3.93363428e-01 2.24165656e-01 4.52752723e-01 2.62362294 0.20169202 203.25 -4.14332194e-01 1.55417925e-01 4.42522201e-01 2.78273025 0.16677725 203.50 -4.00829670e-01 5.49851507e-02 4.04583479e-01 3.00526519 0.12870175 203.75 -3.28363392e-01 5.66341184e-02 3.33211556e-01 2.97079906 0.07252679 204.00 -3.90311184e-01 7.24522043e-02 3.96978768e-01 2.95805493 0.08998324 204.25 -2.98758303e-01 1.28382438e-01 3.25174682e-01 2.73573087 0.05897307 204.50 -4.08753841e-02 -7.69546191e-02 8.71367340e-02 -2.05906179 0.00427879 204.75 -1.07574152e-02 -1.22033351e-01 1.22506574e-01 -1.65872049 0.00816399 205.00 2.00366111e-01 -2.60651536e-03 2.00383064e-01 -0.01300803 0.02250142 205.25 -1.71366417e-04 -5.48386057e-02 5.48388734e-02 -1.57392124 0.00124302 205.50 -3.28322935e-01 -3.75948044e-01 4.99132128e-01 -2.28867401 0.06977331 205.75 -3.22894253e-01 -4.16217303e-01 5.26780355e-01 -2.23059531 0.06828247 206.00 -2.93422752e-01 -2.78683766e-01 4.04674626e-01 -2.38195145 0.05334569 206.25 -4.46997271e-01 -2.65635173e-01 5.19969812e-01 -2.60540017 0.07982231 206.50 -5.67187134e-01 -3.33072887e-01 6.57752836e-01 -2.61061108 0.10175395 206.75 -5.12397859e-01 -2.26906380e-01 5.60390998e-01 -2.72471526 0.07219567 207.00 -7.54223811e-01 -4.56950169e-03 7.54237653e-01 -3.13553418 0.11411526 207.25 -7.48038471e-01 -2.40848278e-02 7.48426104e-01 -3.10940646 0.12885247 207.50 -3.64439589e-01 1.17199076e-01 3.82820895e-01 2.83045068 0.03372450 207.75 -4.33833352e-01 1.40675621e-01 4.56071275e-01 2.82802850 0.05479352 208.00 -3.42728468e-01 2.97983162e-01 4.54155004e-01 2.42591817 0.08630750 208.25 -2.52031723e-01 2.59008547e-01 3.61393714e-01 2.34254314 0.05116927 208.50 -2.33643647e-02 4.10137659e-01 4.10802621e-01 1.62770195 0.06919888 208.75 -1.63716673e-01 1.77266572e-01 2.41301858e-01 2.31647766 0.01844989 209.00 -2.68985076e-02 -9.00069535e-02 9.39403076e-02 -1.86119702 0.00226441 209.25 -2.40178113e-01 6.58476636e-02 2.49041043e-01 2.87400588 0.01475951 209.50 -5.43758791e-02 3.16308144e-01 3.20947937e-01 1.74104024 0.02278772 209.75 6.06012554e-02 1.49852688e-02 6.24265203e-02 0.24241377 0.00075405 210.00 1.30560243e-01 -3.31746729e-01 3.56513491e-01 -1.19585919 0.02579450 210.25 -7.84030231e-02 -4.27472477e-01 4.34602983e-01 -1.75219094 0.04713162 210.50 -2.38409287e-01 -6.24054410e-01 6.68044081e-01 -1.93571849 0.10916185 210.75 -1.67865229e-01 -3.57367945e-01 3.94829816e-01 -2.00993325 0.04515481 211.00 -2.68788098e-01 -3.50586028e-01 4.41766459e-01 -2.22488889 0.05561093 211.25 -3.70670048e-01 -2.63203703e-01 4.54612444e-01 -2.52413660 0.07663210 211.50 -4.64614223e-01 -1.32998800e-01 4.83275343e-01 -2.86279186 0.08981984 211.75 -4.51113019e-01 -1.88283386e-01 4.88828794e-01 -2.74619797 0.05939083 212.00 -5.25922266e-01 -2.58405039e-01 5.85975592e-01 -2.68489948 0.08112359 212.25 -5.53864925e-01 -1.96718408e-01 5.87762271e-01 -2.80031596 0.08379463 212.50 -4.18158025e-01 -2.40969649e-01 4.82620457e-01 -2.61880854 0.05510250 212.75 -3.91940664e-01 -7.70202958e-02 3.99436616e-01 -2.94755502 0.05786354 213.00 -4.82238225e-01 -5.72692650e-02 4.85626888e-01 -3.02338906 0.08324520 213.25 -6.98887588e-01 -2.16797791e-01 7.31741172e-01 -2.84080079 0.12074624 213.50 -6.57607750e-01 -2.87782417e-01 7.17820780e-01 -2.72908135 0.12948430 213.75 -5.39145120e-01 3.80955990e-02 5.40489348e-01 3.07105063 0.08017806 214.00 -5.00550805e-01 2.41099840e-01 5.55589994e-01 2.69271704 0.10321740 214.25 -5.05259929e-01 6.64107969e-02 5.09605720e-01 3.01090295 0.10677785 214.50 -4.22029498e-01 9.34807744e-02 4.32258664e-01 2.92360925 0.07645827 214.75 -3.93322964e-01 1.03308778e-01 4.06664059e-01 2.88473805 0.06891747 215.00 -3.52693745e-01 2.04534065e-01 4.07709531e-01 2.61606892 0.06095641 215.25 -2.71874545e-01 -1.71477404e-02 2.72414781e-01 -3.07860384 0.03548167 215.50 -3.34126879e-01 -1.43016803e-01 3.63448177e-01 -2.73715717 0.05588628 215.75 -2.97623633e-01 -3.16356954e-01 4.34351873e-01 -2.32569269 0.06993478 216.00 -3.10132783e-01 -3.02764155e-01 4.33414901e-01 -2.36821653 0.06748594 216.25 -2.63130583e-01 -1.84566810e-01 3.21407235e-01 -2.52990983 0.03539945 216.50 -3.59765420e-01 -1.45123466e-01 3.87932955e-01 -2.75817280 0.04376768 216.75 -4.86668591e-01 -4.82271109e-02 4.89052320e-01 -3.04281872 0.07367763 217.00 -5.18701021e-01 -1.43079199e-01 5.38072863e-01 -2.87244440 0.09758444 217.25 -6.06940434e-01 -7.19161559e-02 6.11186244e-01 -3.02365291 0.11781811 217.50 -6.90865529e-01 -8.87832851e-02 6.96546948e-01 -3.01378294 0.16092516 217.75 -9.45262208e-01 9.23931024e-02 9.49766880e-01 3.04415880 0.35246216 218.00 -7.48624809e-01 1.84271366e-01 7.70970195e-01 2.90024410 0.24064636 218.25 -7.00198395e-01 3.39542052e-01 7.78181596e-01 2.69007953 0.32861889 218.50 -8.32302975e-01 4.03483789e-01 9.24947247e-01 2.69019506 0.40230967 218.75 -9.10273086e-01 6.25377457e-01 1.10439760e+00 2.53963010 0.54850450 219.00 -9.42508558e-01 7.30705079e-01 1.19258220e+00 2.48210964 0.58142762 219.25 -1.01536072e+00 8.34598729e-01 1.31434867e+00 2.45359662 0.68546060 219.50 -9.30804238e-01 8.23917673e-01 1.24307557e+00 2.41703300 0.70496299 219.75 -9.49571844e-01 8.45537051e-01 1.27146356e+00 2.41408432 0.78713813 220.00 -6.66645847e-01 1.00861176e+00 1.20901380e+00 2.15483349 0.74999663 220.25 -5.42674080e-01 1.14360152e+00 1.26582763e+00 2.01386172 0.81474952 220.50 -3.51599774e-01 1.06068528e+00 1.11744157e+00 1.89088120 0.75542089 220.75 -1.78448425e-01 9.99302588e-01 1.01511059e+00 1.74750667 0.76876532 221.00 1.07127929e-01 8.26767997e-01 8.33679623e-01 1.44193992 0.61979287 221.25 3.78684001e-01 6.35134462e-01 7.39457475e-01 1.03315607 0.53066317 221.50 2.30506849e-01 3.33160202e-03 2.30530925e-01 0.01445237 0.06236038 221.75 -1.91390143e-01 -9.24227208e-02 2.12537399e-01 -2.69171661 0.06494318 222.00 -4.25147965e-01 -1.03586913e-01 4.37585467e-01 -2.90260020 0.31839260 222.25 -4.87426954e-01 -7.14908657e-02 4.92641837e-01 -2.99596110 0.43948255 222.50 -6.75185301e-01 -4.90585307e-03 6.75203123e-01 -3.13432685 0.52835613 222.75 -7.35241300e-01 2.31743702e-02 7.35606430e-01 3.11008368 0.62494047 223.00 -8.34699343e-01 1.63779056e-01 8.50615408e-01 2.94784085 0.70868064 223.25 -8.19510874e-01 3.01539017e-01 8.73226117e-01 2.78901710 0.79008206 223.50 -8.25469562e-01 3.88893453e-01 9.12490063e-01 2.70131656 0.84706439 223.75 -7.59306214e-01 4.22239611e-01 8.68810806e-01 2.63408885 0.87124274 224.00 -7.48075298e-01 3.99720578e-01 8.48170497e-01 2.65085813 0.85279875 224.25 -7.24940413e-01 3.43434004e-01 8.02175490e-01 2.69917204 0.80708055 224.50 -7.90908189e-01 2.71297018e-01 8.36144626e-01 2.81114993 0.78684857 224.75 -7.81957619e-01 3.78946426e-01 8.68940799e-01 2.69033066 0.76769296 225.00 -6.44331856e-01 4.95906814e-01 8.13072634e-01 2.48563682 0.75754210 225.25 -5.79196826e-01 4.06068567e-01 7.07361749e-01 2.53013614 0.69192280 225.50 -5.05774603e-01 3.86605387e-01 6.36609515e-01 2.48894995 0.70902588 225.75 -5.19529272e-01 3.66029296e-01 6.35521920e-01 2.52782602 0.67689265 226.00 -5.85454129e-01 3.35562333e-01 6.74802650e-01 2.62113785 0.59428009 226.25 -5.37015415e-01 3.09200184e-01 6.19669517e-01 2.61917595 0.47537727 226.50 -4.96280349e-01 4.38416741e-01 6.62195910e-01 2.41802186 0.36912120 226.75 -2.09738613e-01 4.93821577e-01 5.36516575e-01 1.97243444 0.17992248 227.00 1.21325698e-01 4.27895296e-01 4.44763206e-01 1.29450743 0.17421016 227.25 1.87741885e-01 -5.37525525e-02 1.95285309e-01 -0.27885118 0.02536157 227.50 2.00465881e-01 -6.18369315e-01 6.50051674e-01 -1.25730200 0.21708341 227.75 -4.13541992e-01 -6.86517969e-01 8.01451122e-01 -2.11296110 0.28189893 228.00 -9.33496695e-01 -6.18847854e-01 1.11999498e+00 -2.55617780 0.54113103 228.25 -1.06865096e+00 -5.20601587e-01 1.18871396e+00 -2.68827153 0.51009137 228.50 -1.30268617e+00 -3.49621496e-01 1.34878703e+00 -2.87938665 0.54594319 228.75 -1.34952648e+00 -3.01192911e-01 1.38272878e+00 -2.92200724 0.52253859 229.00 -1.65738965e+00 -2.09624965e-01 1.67059363e+00 -3.01578169 0.56401203 229.25 -1.74126054e+00 4.99504097e-01 1.81148906e+00 2.86223083 0.47699109 229.50 -1.25481655e+00 1.20846647e+00 1.74211244e+00 2.37500865 0.45044102 229.75 -9.49065794e-01 8.04506886e-01 1.24416929e+00 2.43844530 0.40628424 230.00 -9.19349418e-01 6.92040895e-01 1.15070585e+00 2.49633344 0.53414161 230.25 -8.54911664e-01 5.15655821e-01 9.98386137e-01 2.59884660 0.35003856 230.50 -8.56244616e-01 5.26830647e-01 1.00533844e+00 2.59001316 0.29812626 230.75 -1.02829597e+00 4.96923350e-01 1.14207068e+00 2.69143515 0.39436240 231.00 -1.29244580e+00 5.86119910e-01 1.41913801e+00 2.71583467 0.49696189 231.25 -9.88138032e-01 6.83922252e-01 1.20173475e+00 2.53616656 0.34918147 231.50 -9.26399417e-01 7.18683318e-01 1.17248522e+00 2.48179467 0.41772299 231.75 -8.19414475e-01 7.43998659e-01 1.10678547e+00 2.40439506 0.33933366 232.00 -7.43365470e-01 8.38637198e-01 1.12067148e+00 2.29604491 0.36979934 232.25 -7.14369753e-01 6.01791164e-01 9.34064639e-01 2.44152238 0.24643579 232.50 -6.77593584e-01 9.87561939e-01 1.19766926e+00 2.17215121 0.36876012 232.75 -7.42789244e-01 1.02065979e+00 1.26233207e+00 2.19990732 0.44294040 233.00 -6.49155989e-01 1.08213067e+00 1.26190740e+00 2.11113265 0.48603495 233.25 -7.74797062e-01 9.60415916e-01 1.23398104e+00 2.24962794 0.41491644 233.50 -8.00489149e-01 1.01584878e+00 1.29334126e+00 2.23817744 0.41655688 233.75 -5.48346999e-01 7.39509315e-01 9.20629382e-01 2.20883594 0.28687948 234.00 -4.47549785e-01 9.28340857e-01 1.03059088e+00 2.02001874 0.33480108 234.25 -4.50755474e-01 9.87581057e-01 1.08558594e+00 1.99897941 0.36205860 234.50 -4.55626772e-01 1.08056895e+00 1.17269988e+00 1.96982991 0.48670644 234.75 -6.27137220e-01 1.02243754e+00 1.19944971e+00 2.12099210 0.52702362 235.00 -6.99368370e-01 1.12345623e+00 1.32335559e+00 2.12760669 0.53369797 235.25 -3.16586669e-01 1.27717561e+00 1.31582851e+00 1.81377898 0.45905637 235.50 -6.82316400e-02 1.16695240e+00 1.16894545e+00 1.62919977 0.39586235 235.75 2.19481729e-01 8.75936020e-01 9.03015028e-01 1.32528294 0.37983691 236.00 1.25057307e-01 7.40848194e-01 7.51329073e-01 1.40356990 0.33048058 236.25 -2.32773974e-01 5.26547451e-01 5.75704735e-01 1.98704112 0.37123222 236.50 -3.44341131e-01 4.10868655e-01 5.36081958e-01 2.26832985 0.31349662 236.75 -6.81600490e-01 3.77688790e-01 7.79248388e-01 2.63559143 0.48840983 237.00 -8.62947691e-01 4.18229750e-01 9.58955077e-01 2.69029826 0.55324708 237.25 -1.00921817e+00 5.06570114e-01 1.12921858e+00 2.67639176 0.62317611 237.50 -1.12896898e+00 3.75985551e-01 1.18993113e+00 2.82011113 0.58420408 237.75 -1.25172343e+00 2.36049527e-01 1.27378606e+00 2.95520196 0.72543219 238.00 -1.36913545e+00 -1.32865250e-01 1.37556717e+00 -3.04485240 0.63911642 238.25 -1.26833213e+00 -7.68051072e-01 1.48275718e+00 -2.59709502 0.60409585 238.50 -1.23853055e+00 -9.87574756e-01 1.58406497e+00 -2.46845365 0.59090931 238.75 -1.25134116e+00 -1.25940595e+00 1.77537546e+00 -2.35298239 0.68318494 239.00 -5.56214231e-01 -1.27282518e+00 1.38904939e+00 -1.98278018 0.53700730 239.25 -7.35590925e-02 -1.34154900e+00 1.34356416e+00 -1.62557294 0.69336447 239.50 2.45955456e-01 -1.01846926e+00 1.04774697e+00 -1.33383804 0.57235810 239.75 5.29407956e-01 -7.14252960e-01 8.89061345e-01 -0.93294774 0.53071000 240.00 6.97517633e-01 -5.76979469e-01 9.05227129e-01 -0.69110161 0.45409149 240.25 9.24044787e-01 -5.60914839e-01 1.08096449e+00 -0.54556621 0.56475650 240.50 1.14908497e+00 -4.66910954e-01 1.24032339e+00 -0.38595377 0.62926038 240.75 1.25084132e+00 -3.27279864e-01 1.29294861e+00 -0.25591089 0.62728323 241.00 1.35240969e+00 -7.26732827e-01 1.53530211e+00 -0.49308815 0.61322872 241.25 1.48482492e+00 -9.38366459e-01 1.75648417e+00 -0.56359655 0.68977256 241.50 1.44077682e+00 -1.13210634e+00 1.83234893e+00 -0.66599816 0.73343704 241.75 1.41638404e+00 -1.10956088e+00 1.79924126e+00 -0.66452167 0.77643501 242.00 1.23436037e+00 -1.02954341e+00 1.60735969e+00 -0.69517309 0.74804796 242.25 1.13234294e+00 -1.15481931e+00 1.61734603e+00 -0.79522504 0.74666160 242.50 9.96785214e-01 -1.13009535e+00 1.50688296e+00 -0.84799499 0.66099346 242.75 8.81758220e-01 -1.14434051e+00 1.44464970e+00 -0.91427974 0.63508152 243.00 7.77080255e-01 -1.60698733e+00 1.78501036e+00 -1.12038425 0.69152926 243.25 5.72947738e-01 -1.78929536e+00 1.87878871e+00 -1.26090418 0.75256980 243.50 2.57951446e-01 -1.69860943e+00 1.71808409e+00 -1.42008745 0.66694220 243.75 1.39213792e-01 -1.63645962e+00 1.64237041e+00 -1.48593055 0.62633453 244.00 -1.31991096e-01 -1.55058244e+00 1.55619008e+00 -1.65571517 0.47617734 244.25 -3.94237559e-01 -1.56995985e+00 1.61870231e+00 -1.81682238 0.51656552 244.50 -1.01940175e+00 -1.61870570e+00 1.91295271e+00 -2.13281374 0.65260724 244.75 -1.29644523e+00 -1.37821554e+00 1.89215441e+00 -2.32563179 0.71582574 245.00 -1.18726418e+00 -8.51976067e-01 1.46132114e+00 -2.51915463 0.59909254 245.25 -1.15159270e+00 -4.93276205e-01 1.25279175e+00 -2.73689421 0.55659370 245.50 -8.39478914e-01 -3.58575450e-01 9.12853329e-01 -2.73791037 0.48384598 245.75 -7.42102713e-01 -1.67645360e-01 7.60803130e-01 -2.91941616 0.36222973 246.00 -5.82946241e-01 -8.55355984e-02 5.89188135e-01 -2.99590245 0.20481775 246.25 -6.02968534e-01 1.71781412e-02 6.03213181e-01 3.11311107 0.20279877 246.50 -7.57522123e-01 1.99644039e-01 7.83388479e-01 2.88390340 0.28697239 246.75 -6.40157294e-01 2.00672108e-01 6.70873056e-01 2.83782148 0.18862659 247.00 -3.19268853e-01 4.06602110e-01 5.16969899e-01 2.23645492 0.09992376 247.25 -1.18447551e-01 4.32891029e-01 4.48803370e-01 1.83787891 0.07710640 247.50 -1.84357532e-01 2.13150790e-01 2.81817244e-01 2.28388642 0.03616147 247.75 -1.37662675e-01 1.50521567e-01 2.03979788e-01 2.31160368 0.01615388 248.00 9.98926798e-02 1.00748998e-01 1.41876383e-01 0.78966603 0.00811437 248.25 1.40974566e-02 5.05256483e-02 5.24554994e-02 1.29870046 0.00083295 248.50 1.36072016e-02 -3.30143395e-02 3.57085780e-02 -1.17985105 0.00024733 248.75 2.43218836e-01 -1.45434135e-01 2.83383997e-01 -0.53891512 0.01222276 249.00 5.56364361e-01 -5.68824624e-01 7.95677544e-01 -0.79647164 0.08613950 249.25 4.33946582e-01 -3.04517360e-01 5.30132492e-01 -0.61189231 0.03717396 249.50 1.14226253e-01 -2.86426381e-01 3.08362949e-01 -1.19132663 0.01563382 249.75 2.01577595e-02 -4.11347666e-01 4.11841277e-01 -1.52183131 0.01166224 250.00 -9.11251693e-02 1.11257456e+00 1.11630012e+00 1.65251869 0.03862402 250.25 -2.65342304e-01 -5.87703317e-02 2.71772866e-01 -2.92362279 0.00573253 250.50 -4.95815485e-01 -7.84824439e-01 9.28322355e-01 -2.13423727 0.09795415 250.75 -9.09468589e-01 -8.52079537e-01 1.24626348e+00 -2.38876173 0.14672416 251.00 -9.42723097e-01 -4.06220537e-01 1.02651934e+00 -2.73473425 0.11082534 251.25 -9.70250315e-01 -3.75727718e-02 9.70977542e-01 -3.10288717 0.13863666 251.50 -7.06552265e-01 3.55217894e-02 7.07444627e-01 3.09136012 0.09393281 251.75 -4.38879447e-01 -1.91823130e-01 4.78968978e-01 -2.72953919 0.05085426 252.00 -4.41748514e-01 -2.17799268e-02 4.42285106e-01 -3.09232864 0.03762204 252.25 -6.52047787e-03 -1.94897580e-01 1.95006624e-01 -1.60423977 0.00855968 252.50 1.69151673e-01 -7.50437318e-01 7.69264881e-01 -1.34909726 0.16978897 252.75 -2.02916498e-01 -1.06169464e+00 1.08091194e+00 -1.75964395 0.33284251 253.00 -4.39235743e-01 -1.14663292e+00 1.22788236e+00 -1.93661948 0.44373363 253.25 -8.11985227e-01 -9.77195482e-01 1.27052391e+00 -2.26411710 0.50621098 253.50 -7.67593874e-01 -8.58726920e-01 1.15178656e+00 -2.30021670 0.52273704 253.75 -1.16935556e+00 -6.40287430e-01 1.33317681e+00 -2.64062792 0.53354147 254.00 -1.37646294e+00 -6.37420082e-01 1.51688977e+00 -2.70791023 0.60841602 254.25 -1.39145517e+00 -3.17563254e-01 1.42723296e+00 -2.91721183 0.61141831 254.50 -1.34126901e+00 -2.55334746e-01 1.36535650e+00 -2.95347552 0.63199028 254.75 -1.47985871e+00 -3.24424123e-01 1.51500257e+00 -2.92578034 0.62614288 255.00 -1.25597985e+00 -2.27352921e-01 1.27639129e+00 -2.96251541 0.56449183 255.25 -1.11957680e+00 -4.16446108e-02 1.12035106e+00 -3.10441305 0.49573904 255.50 -1.08229012e+00 -6.63251317e-02 1.08432049e+00 -3.08038699 0.47278271 255.75 -1.03121350e+00 1.30760811e-01 1.03947086e+00 3.01546294 0.47093558 256.00 -1.12510177e+00 2.15944934e-01 1.14563790e+00 2.95196505 0.45333642 256.25 -1.25047567e+00 1.52485788e-01 1.25973859e+00 3.02024951 0.42332047 256.50 -1.42895243e+00 8.53191934e-03 1.42897790e+00 3.13562197 0.49275424 256.75 -1.84885341e+00 2.54741212e-01 1.86632045e+00 3.00467141 0.66564960 257.00 -1.56014792e+00 7.32622400e-01 1.72360005e+00 2.70257156 0.58731478 257.25 -8.69895451e-01 1.29186283e+00 1.55744267e+00 2.16342204 0.62269719 257.50 -6.64860906e-01 1.23344773e+00 1.40122565e+00 2.06517550 0.67407056 257.75 -2.40640613e-01 9.91251297e-01 1.02004266e+00 1.80895359 0.63392394 258.00 -2.67943935e-01 8.01750113e-01 8.45338510e-01 1.89332561 0.51117578 258.25 -3.89935290e-01 7.57746369e-01 8.52190759e-01 2.04605456 0.59366879 258.50 -3.02114202e-01 6.54078110e-01 7.20479816e-01 2.00349647 0.48816823 258.75 -2.37457422e-01 5.76364287e-01 6.23363312e-01 1.96159762 0.51912003 259.00 -2.16696910e-01 5.19886467e-01 5.63240170e-01 1.96571454 0.43858055 259.25 -1.98357863e-01 4.11953884e-01 4.57221877e-01 2.01953878 0.34954633 259.50 -2.79895910e-01 4.23003530e-01 5.07221556e-01 2.15534350 0.37558426 259.75 -3.94776653e-01 4.60846718e-01 6.06818180e-01 2.27912879 0.49845922 260.00 -3.98379596e-01 4.09162670e-01 5.71069517e-01 2.34284233 0.40948203 260.25 -3.30054399e-01 3.27032641e-01 4.64635615e-01 2.36079317 0.32351930 260.50 -6.15153324e-01 3.53063923e-01 7.09272687e-01 2.62055190 0.41940484 260.75 -7.32997916e-01 2.42026925e-01 7.71921613e-01 2.82267580 0.53208992 261.00 -8.13542562e-01 3.84123874e-01 8.99668078e-01 2.70046242 0.52913076 261.25 -8.83110708e-01 4.90906868e-01 1.01038313e+00 2.63424341 0.57967151 261.50 -6.59192502e-01 8.44800965e-01 1.07155188e+00 2.23340493 0.51438875 261.75 -4.16019307e-01 1.17909938e+00 1.25033892e+00 1.90998832 0.64737690 262.00 -3.64697783e-02 9.84021090e-01 9.84696679e-01 1.60784136 0.51923850 262.25 1.14499682e-01 9.02680700e-01 9.09913525e-01 1.44462606 0.58427623 262.50 1.11339607e-01 7.36816230e-01 7.45180961e-01 1.42082190 0.51254467 262.75 1.91142482e-01 7.18155022e-01 7.43156837e-01 1.31066918 0.62687036 263.00 1.89795697e-01 6.35102810e-01 6.62855931e-01 1.28040182 0.48495551 263.25 2.03350161e-01 6.13605489e-01 6.46423224e-01 1.25078487 0.53587218 263.50 3.78797541e-02 3.97655331e-01 3.99455427e-01 1.47582514 0.28478295 263.75 2.37684112e-02 3.85329248e-01 3.86061610e-01 1.50919100 0.31579445 264.00 -4.67771929e-02 4.44869062e-01 4.47321571e-01 1.67555959 0.33004927 264.25 -1.80606732e-02 4.12901779e-01 4.13296585e-01 1.61450931 0.36749857 264.50 5.55145098e-02 4.97951349e-01 5.01036333e-01 1.45976899 0.45758433 264.75 1.46875730e-02 5.02313231e-01 5.02527916e-01 1.54156479 0.46156962 265.00 -1.24980117e-02 4.41225914e-01 4.41402885e-01 1.59911441 0.34139212 265.25 4.56713627e-02 4.55709933e-01 4.57992812e-01 1.47090961 0.31836012 265.50 6.75109979e-02 3.70771794e-01 3.76867958e-01 1.39068713 0.35320789 265.75 3.57785817e-02 3.35049737e-01 3.36954645e-01 1.46441359 0.31792952 266.00 1.10060268e-01 3.96338217e-01 4.11335928e-01 1.29992837 0.37325646 266.25 7.56982642e-02 3.91502390e-01 3.98753494e-01 1.37979995 0.33366529 266.50 7.51930380e-02 3.49987813e-01 3.57974108e-01 1.35916858 0.33233275 266.75 9.93224251e-02 3.40140317e-01 3.54345001e-01 1.28669111 0.28252529 267.00 1.60044976e-02 4.20610316e-01 4.20914697e-01 1.53276402 0.30196362 267.25 9.20213186e-02 4.40944457e-01 4.50444155e-01 1.36505778 0.31786365 267.50 1.17453408e-01 3.41717436e-01 3.61339327e-01 1.23973155 0.20368741 267.75 1.13344345e-01 2.99624484e-01 3.20346331e-01 1.20914615 0.13675757 268.00 1.64371904e-01 1.26323143e-01 2.07305714e-01 0.65524911 0.09750716 268.25 6.93455659e-02 3.80325798e-02 7.90903574e-02 0.50165246 0.01374946 268.50 2.95969908e-03 3.10449255e-02 3.11856893e-02 1.47574759 0.00388721 268.75 -1.23670495e-01 4.21960405e-02 1.30670950e-01 2.81278129 0.05832377 269.00 -3.14139078e-01 1.20931058e-01 3.36612063e-01 2.77411843 0.33017479 269.25 -3.88803887e-01 2.65085143e-01 4.70572626e-01 2.54318854 0.46405398 269.50 -4.43391268e-01 5.09671532e-01 6.75544882e-01 2.28676179 0.70230793 269.75 -4.55530197e-01 5.82510543e-01 7.39477040e-01 2.23447229 0.66678396 270.00 -3.66516449e-01 7.02959588e-01 7.92771398e-01 2.05140953 0.65762584 270.25 -1.54865388e-01 8.67018212e-01 8.80740523e-01 1.74755068 0.55626874 270.50 -8.38827003e-02 9.60408575e-01 9.64064800e-01 1.65791589 0.54785564 270.75 5.17091712e-02 9.42300705e-01 9.43718421e-01 1.51597586 0.53636121 271.00 2.13116533e-01 1.03988122e+00 1.06149499e+00 1.36865229 0.60146531 271.25 4.89027582e-01 1.34548902e+00 1.43160354e+00 1.22218363 0.68397986 271.50 8.02989253e-01 1.56676679e+00 1.76055387e+00 1.09718804 0.73405195 271.75 1.26503987e+00 1.29423506e+00 1.80979841e+00 0.79680527 0.58893819 272.00 1.78892444e+00 1.04831172e+00 2.07345319e+00 0.53006261 0.60900471 272.25 2.39992410e+00 7.95703824e-02 2.40124283e+00 0.03314323 0.57277606 272.50 3.04296779e+00 -5.95454729e-01 3.10068046e+00 -0.19324043 0.74885961 272.75 2.44293533e+00 -1.61503805e+00 2.92852880e+00 -0.58414270 0.74738747 273.00 2.11709521e+00 -2.41737968e+00 3.21338088e+00 -0.85152416 0.81888692 273.25 6.48279420e-01 -3.07372926e+00 3.14134968e+00 -1.36293298 0.73075866 273.50 -2.35705459e-01 -3.02000341e+00 3.02918762e+00 -1.64868650 0.82131852 273.75 -8.34896161e-01 -2.42553526e+00 2.56520426e+00 -1.90230472 0.78215730 274.00 -1.17238738e+00 -2.06065861e+00 2.37082393e+00 -2.08806306 0.78352526 274.25 -1.13871109e+00 -1.32190140e+00 1.74473100e+00 -2.28188252 0.66306144 274.50 -1.20037009e+00 -1.23103858e+00 1.71940232e+00 -2.34358169 0.71858113 274.75 -1.33611104e+00 -1.05666996e+00 1.70345065e+00 -2.47245292 0.77104162 275.00 -1.39981572e+00 -8.38193707e-01 1.63157983e+00 -2.60206436 0.79112706 275.25 -1.37347584e+00 -7.36185630e-01 1.55833410e+00 -2.64956004 0.79615471 275.50 -1.39042588e+00 -6.26077150e-01 1.52487925e+00 -2.71850818 0.83347812 275.75 -1.32361122e+00 -5.00369661e-01 1.41503232e+00 -2.78016495 0.78155407 276.00 -1.31252396e+00 -4.28339322e-01 1.38064974e+00 -2.82614219 0.77891797 276.25 -1.36286731e+00 -3.00470108e-01 1.39559650e+00 -2.92459496 0.71996095 276.50 -1.30063370e+00 -2.47552699e-01 1.32398276e+00 -2.95350993 0.61916179 276.75 -1.30247844e+00 -3.73402956e-01 1.35494644e+00 -2.86239441 0.60761867 277.00 -1.38723401e+00 -2.97417325e-01 1.41875835e+00 -2.93039395 0.53566932 277.25 -1.60107710e+00 -1.84754307e-01 1.61170159e+00 -3.02670702 0.50160082 277.50 -1.66241329e+00 -1.12599280e-01 1.66622223e+00 -3.07396352 0.45661784 277.75 -1.26345237e+00 -2.07003376e-01 1.28029773e+00 -2.97919601 0.23755539 278.00 -1.24117134e+00 6.90739903e-03 1.24119056e+00 3.13602749 0.17848314 278.25 -1.11035738e+00 6.25935332e-01 1.27463271e+00 2.62827372 0.14473042 278.50 -2.43512987e-02 1.39910074e+00 1.39931264e+00 1.58819953 0.20035759 278.75 1.25137872e+00 1.61164548e+00 2.04042883e+00 0.91057458 0.42945572 279.00 1.31737701e+00 1.16726025e+00 1.76010758e+00 0.72505354 0.45410281 279.25 1.18758024e+00 7.59632052e-01 1.40974738e+00 0.56906267 0.48921897 279.50 9.81077717e-01 4.01049936e-01 1.05988421e+00 0.38805671 0.46522737 279.75 8.56432973e-01 3.00809640e-01 9.07724560e-01 0.33777504 0.55616725 280.00 6.59801763e-01 2.71022148e-01 7.13296132e-01 0.38975025 0.37638999 280.25 3.59227194e-01 3.77033327e-01 5.20767037e-01 0.80957801 0.28431819 280.50 3.39592823e-01 4.44533426e-01 5.59404373e-01 0.91843889 0.33870198 280.75 3.08655739e-01 4.84750297e-01 5.74674878e-01 1.00380539 0.48767558 281.00 2.55431264e-01 3.79762901e-01 4.57673455e-01 0.97869231 0.37173057 281.25 2.74112709e-01 3.64987852e-01 4.56458004e-01 0.92664356 0.43094460 281.50 2.22549487e-01 3.02085970e-01 3.75212216e-01 0.93585579 0.29189788 281.75 1.89314505e-01 2.78659203e-01 3.36884154e-01 0.97404617 0.35642590 282.00 1.70669732e-01 3.12600632e-01 3.56156303e-01 1.07105449 0.37269358 282.25 1.79184143e-01 2.67428688e-01 3.21908466e-01 0.98047172 0.32319769 282.50 1.83723084e-01 3.11447009e-01 3.61598411e-01 1.03783522 0.34447881 282.75 1.74020682e-01 3.63415590e-01 4.02931866e-01 1.12421338 0.47104670 283.00 1.38843754e-01 3.58170030e-01 3.84139765e-01 1.20098371 0.42468681 283.25 1.35333812e-01 3.44397642e-01 3.70033751e-01 1.19637533 0.45783940 283.50 1.93790180e-01 3.32776671e-01 3.85090829e-01 1.04346107 0.39874640 283.75 2.42520837e-01 3.80034574e-01 4.50824393e-01 1.00279335 0.53933016 284.00 2.77622178e-01 5.03383936e-01 5.74864733e-01 1.06679317 0.61193166 284.25 3.48300154e-01 5.17700380e-01 6.23960480e-01 0.97857110 0.70210053 284.50 4.43628515e-01 4.27834950e-01 6.16318914e-01 0.76727711 0.70949126 284.75 5.18280107e-01 3.76814013e-01 6.40783169e-01 0.62864865 0.75436522 285.00 4.51329029e-01 2.64287761e-01 5.23016169e-01 0.52974662 0.59387365 285.25 4.21992068e-01 2.16751949e-01 4.74403534e-01 0.47449986 0.57962229 285.50 4.42418194e-01 1.40365016e-01 4.64151049e-01 0.30722251 0.67225366 285.75 4.24769860e-01 1.08371121e-01 4.38376247e-01 0.24980013 0.69909270 286.00 3.57645902e-01 1.39343571e-01 3.83832284e-01 0.37152031 0.69027120 286.25 3.63504276e-01 1.26551243e-01 3.84903333e-01 0.33501896 0.71882672 286.50 3.00962256e-01 4.69181856e-02 3.04597432e-01 0.15464913 0.54585334 286.75 2.68972947e-01 3.00822612e-02 2.70649937e-01 0.11137836 0.55294759 287.00 2.72214221e-01 -8.91319736e-03 2.72360105e-01 -0.03273163 0.58469398 287.25 2.80175488e-01 4.15144946e-02 2.83234457e-01 0.14710285 0.62252110 287.50 2.58100993e-01 1.15468178e-02 2.58359152e-01 0.04470778 0.68934881 287.75 2.52377161e-01 9.20369149e-03 2.52544926e-01 0.03645185 0.64511549 288.00 2.22718230e-01 3.38765825e-03 2.22743993e-01 0.01520934 0.47476653 288.25 2.29256062e-01 -1.31022304e-02 2.29630160e-01 -0.05708897 0.49978638 288.50 2.30903382e-01 4.60530752e-05 2.30903387e-01 0.00019945 0.63610223 288.75 2.29417295e-01 -1.88187077e-02 2.30187834e-01 -0.08184505 0.59507080 289.00 2.30813476e-01 2.03121590e-02 2.31705513e-01 0.08777636 0.55631694 289.25 2.22985860e-01 -9.34181535e-03 2.23181458e-01 -0.04186972 0.52389119 289.50 1.94103681e-01 -2.20227204e-02 1.95349019e-01 -0.11297542 0.49639716 289.75 1.88990687e-01 -4.12444118e-02 1.93438831e-01 -0.21486631 0.46374281 290.00 1.66130031e-01 -5.89262515e-02 1.76271070e-01 -0.34085537 0.51118875 290.25 1.83307748e-01 -5.87529668e-02 1.92493225e-01 -0.31017045 0.45006218 290.50 1.81170590e-01 -6.31793335e-02 1.91870818e-01 -0.33554156 0.45285209 290.75 1.46092038e-01 -6.05860285e-02 1.58156728e-01 -0.39312391 0.28564456 291.00 1.26868941e-01 -7.19048887e-02 1.45828808e-01 -0.51562352 0.37840385 291.25 1.58559099e-01 -7.62317278e-02 1.75932556e-01 -0.44815210 0.39511143 291.50 1.69081002e-01 -1.16410812e-01 2.05279961e-01 -0.60296023 0.50173941 291.75 1.43238812e-01 -8.55466871e-02 1.66840022e-01 -0.53838113 0.32021973 292.00 1.01946751e-01 -9.17484081e-02 1.37152873e-01 -0.73279522 0.30019715 292.25 1.06288435e-01 -1.22503509e-01 1.62186131e-01 -0.85615243 0.29765806 292.50 7.34369928e-02 -1.49552314e-01 1.66609983e-01 -1.11433793 0.28646032 292.75 4.51582239e-02 -1.20814920e-01 1.28978719e-01 -1.21309551 0.15939484 293.00 6.22863387e-02 -1.23683654e-01 1.38481892e-01 -1.10427770 0.18503580 293.25 -3.63000299e-03 -1.26157310e-01 1.26209523e-01 -1.59956201 0.14923277 293.50 -2.92903203e-02 -9.75381500e-02 1.01841119e-01 -1.86252470 0.14862514 293.75 -5.76244814e-02 -8.76623866e-02 1.04906029e-01 -2.15231807 0.10741633 294.00 -7.60439376e-02 -5.05518055e-02 9.13135559e-02 -2.55490357 0.06817800 294.25 -5.40308657e-02 -5.02815686e-02 7.38076594e-02 -2.39212198 0.04644774 294.50 -6.74871950e-02 -4.33937827e-02 8.02342936e-02 -2.57015917 0.05263372 294.75 -8.46119895e-02 2.68837110e-02 8.87801931e-02 2.83395081 0.04596642 295.00 -1.10403428e-01 3.89680400e-02 1.17078713e-01 2.80228293 0.08653229 295.25 -7.52298468e-02 2.37961700e-02 7.89036600e-02 2.83523790 0.02929550 295.50 -7.16784566e-02 1.53480807e-02 7.33032382e-02 2.93065390 0.02554593 295.75 -1.75271165e-02 1.53166533e-01 1.54166101e-01 1.68473250 0.05349648 296.00 6.02110522e-02 2.19131471e-01 2.27253103e-01 1.30264269 0.11508933 296.25 4.75060701e-02 6.46137390e-02 8.01982665e-02 0.93681411 0.01741717 296.50 3.28106916e-02 1.06421100e-01 1.11364231e-01 1.27173320 0.03737125 296.75 1.15482744e-01 2.32271695e-01 2.59396231e-01 1.10940069 0.24469587 297.00 1.41493802e-01 2.21761539e-01 2.63056412e-01 1.00287141 0.26185408 297.25 5.24230052e-02 1.56831347e-01 1.65360947e-01 1.24820880 0.10197972 297.50 5.62545868e-02 1.29310595e-01 1.41017050e-01 1.16045705 0.06378564 297.75 2.04771545e-01 5.78548494e-02 2.12787616e-01 0.27535659 0.15982535 298.00 2.06522302e-01 6.88033120e-02 2.17681779e-01 0.32158732 0.17618423 298.25 1.12288883e-01 1.01814869e-01 1.51575265e-01 0.73651686 0.09778230 298.50 9.63186376e-02 7.97434770e-02 1.25045200e-01 0.69153100 0.05541349 298.75 5.16617911e-02 1.17100713e-01 1.27990303e-01 1.15530629 0.05369177 299.00 5.38254136e-02 1.34613701e-01 1.44975942e-01 1.19041847 0.04062492 299.25 1.45247189e-01 1.52070340e-01 2.10290595e-01 0.80834317 0.08853148 299.50 1.92962113e-01 9.17881880e-02 2.13680717e-01 0.44400288 0.06844182 299.75 2.14667734e-01 8.69107530e-03 2.14843597e-01 0.04046408 0.06269143 300.00 2.04976132e-01 -2.89043774e-02 2.07004052e-01 -0.14008970 0.05032010 300.25 3.42887558e-01 -4.29568107e-02 3.45567887e-01 -0.12463027 0.15727010 300.50 3.09915864e-01 -1.45895614e-01 3.42539594e-01 -0.43998220 0.18415018 300.75 2.66161516e-01 -1.41647833e-01 3.01506320e-01 -0.48906482 0.19161169 301.00 1.84981513e-01 -7.43072768e-02 1.99348267e-01 -0.38197198 0.07600725 301.25 3.02960908e-01 -6.37613447e-02 3.09597837e-01 -0.20743333 0.19942549 301.50 2.54267386e-01 -4.31232124e-02 2.57898264e-01 -0.16799932 0.10772516 301.75 1.81375121e-01 -4.73512833e-02 1.87454204e-01 -0.25536840 0.05444448 302.00 3.16019042e-01 -1.28910340e-01 3.41300323e-01 -0.38731486 0.10366422 302.25 3.45392693e-01 -2.07144069e-01 4.02746543e-01 -0.54022459 0.15200828 302.50 2.92798415e-01 -9.22354643e-02 3.06982561e-01 -0.30517314 0.06510194 302.75 3.98070556e-01 -1.25510536e-01 4.17388383e-01 -0.30543118 0.16294189 303.00 4.31671202e-01 -1.48026675e-01 4.56346276e-01 -0.33034943 0.19231791 303.25 4.80388227e-01 -1.61032467e-01 5.06659949e-01 -0.32344146 0.23015230 303.50 1.96842812e-01 -9.27021461e-02 2.17579366e-01 -0.44013466 0.04184466 303.75 2.33094325e-01 -8.69172917e-02 2.48772145e-01 -0.35691481 0.06554032 304.00 3.03642964e-01 -1.31168075e-01 3.30762927e-01 -0.40776896 0.07704968 304.25 4.11513248e-01 -1.95279454e-01 4.55496673e-01 -0.44307287 0.18118129 304.50 2.28376477e-01 -2.44137020e-01 3.34303305e-01 -0.81874050 0.09203675 304.75 9.89343481e-02 -2.71616827e-01 2.89073876e-01 -1.22149022 0.06966356 305.00 2.00439609e-01 -4.28652927e-01 4.73201193e-01 -1.13340015 0.11605836 305.25 3.27748554e-01 -5.07200062e-01 6.03879969e-01 -0.99710284 0.17714668 305.50 1.60769400e-01 -4.53554651e-01 4.81205384e-01 -1.23014903 0.08817159 305.75 -6.68733925e-02 -6.87462497e-01 6.90707416e-01 -1.66776693 0.16364067 306.00 -4.45053669e-02 -9.59672576e-01 9.60704003e-01 -1.61713870 0.25392812 306.25 -2.81836284e-02 -8.71442868e-01 8.71898497e-01 -1.60312640 0.25831619 306.50 -4.40415977e-01 -6.61238167e-01 7.94482313e-01 -2.15837010 0.21459856 306.75 -4.11214677e-01 -6.99122879e-01 8.11092048e-01 -2.10248418 0.26073639 307.00 -5.63536353e-01 -9.13136076e-01 1.07302876e+00 -2.12372635 0.47420662 307.25 -6.58993345e-01 -9.01117393e-01 1.11637126e+00 -2.20222610 0.56284361 307.50 -5.18360956e-01 -8.47341828e-01 9.93320821e-01 -2.11981042 0.52301703 307.75 -5.93058947e-01 -7.56890961e-01 9.61562708e-01 -2.23542356 0.51267856 308.00 -5.94343045e-01 -6.93893112e-01 9.13636309e-01 -2.27907151 0.49841525 308.25 -5.71844486e-01 -7.70501221e-01 9.59519801e-01 -2.20926871 0.50201618 308.50 -6.12039612e-01 -5.60438203e-01 8.29869547e-01 -2.40017667 0.48453297 308.75 -6.81788939e-01 -5.73079996e-01 8.90649672e-01 -2.44260847 0.48773378 309.00 -6.72422344e-01 -4.22319679e-01 7.94043903e-01 -2.58079794 0.55780067 309.25 -6.13611764e-01 -4.29372964e-01 7.48919581e-01 -2.53103654 0.53089238 309.50 -4.64224891e-01 -3.00854875e-01 5.53189303e-01 -2.56656834 0.39879326 309.75 -5.03292394e-01 -2.86988095e-01 5.79366378e-01 -2.62335703 0.33571316 310.00 -5.22670497e-01 -2.88136765e-01 5.96831001e-01 -2.63776875 0.45183498 310.25 -4.25633783e-01 -2.84444638e-01 5.11930532e-01 -2.55247056 0.30889823 310.50 -2.63338737e-01 -4.71341278e-01 5.39916559e-01 -2.08029504 0.34075416 310.75 -1.98535887e-01 -5.04835910e-01 5.42471930e-01 -1.94548595 0.33681011 311.00 -7.98959260e-02 -6.80476321e-01 6.85150628e-01 -1.68767298 0.49368486 311.25 -7.69240854e-02 -8.28037348e-01 8.31602769e-01 -1.66342975 0.48596972 311.50 -1.26593322e-02 -1.19470247e+00 1.19476954e+00 -1.58139215 0.66018292 311.75 -3.64534914e-01 -1.44324655e+00 1.48857190e+00 -1.81820155 0.61738900 312.00 -5.94563751e-01 -1.85351259e+00 1.94653923e+00 -1.88120371 0.72193799 312.25 -8.91370197e-01 -2.01925696e+00 2.20724704e+00 -1.98650460 0.72812960 312.50 -1.35179912e+00 -1.96806072e+00 2.38759793e+00 -2.17265480 0.71892436 312.75 -1.64343578e+00 -1.44238881e+00 2.18663363e+00 -2.42125432 0.51247018 313.00 -1.82874141e+00 -1.27234400e+00 2.22781382e+00 -2.53372578 0.36520075 313.25 -2.12636737e+00 -6.29950929e-01 2.21771873e+00 -2.85357346 0.30924494 313.50 -2.81978547e+00 -5.29561868e-01 2.86908101e+00 -2.95595280 0.38818556 313.75 -1.21672938e+00 -2.35997774e-02 1.21695823e+00 -3.12219901 0.06698387 314.00 3.92366357e-01 1.31403598e+00 1.37136498e+00 1.28062778 0.08777838 314.25 5.95800261e-01 1.51719651e+00 1.62998871e+00 1.19660045 0.39603703 314.50 5.00782070e-01 1.47066205e+00 1.55358603e+00 1.24259651 0.58442116 314.75 2.77283673e-01 1.21832618e+00 1.24948186e+00 1.34701430 0.54717103 315.00 2.11030943e-01 1.00331797e+00 1.02527119e+00 1.36348516 0.53847079 315.25 2.60134689e-01 1.02235434e+00 1.05493054e+00 1.32163693 0.55135650 315.50 2.91881779e-01 1.02671470e+00 1.06739779e+00 1.29381661 0.57858765 315.75 2.06445956e-01 6.15170463e-01 6.48887225e-01 1.24701483 0.34244781 316.00 1.29638023e-01 5.10647678e-01 5.26846342e-01 1.32217883 0.30933858 316.25 -1.99301208e-02 5.23010292e-01 5.23389889e-01 1.60888445 0.31317879 316.50 -1.15454845e-01 5.00700610e-01 5.13839394e-01 1.79742176 0.31670525 316.75 -1.94370177e-01 5.59338501e-01 5.92148059e-01 1.90524232 0.38003393 317.00 -1.83279110e-01 5.77277264e-01 6.05673403e-01 1.87821974 0.46427607 317.25 -2.02539957e-01 6.45099918e-01 6.76148163e-01 1.87501694 0.41587028 317.50 -3.09402362e-01 6.10598890e-01 6.84515030e-01 2.03980507 0.40449599 317.75 -3.81192761e-01 7.01245133e-01 7.98155785e-01 2.06870813 0.54044400 318.00 -3.71035633e-01 7.94238319e-01 8.76631021e-01 2.00782775 0.59888902 318.25 -3.72028813e-01 8.50142444e-01 9.27980395e-01 1.98329710 0.49641110 318.50 -2.69192248e-01 8.60999396e-01 9.02100009e-01 1.87381868 0.40341882 318.75 -2.25283524e-01 9.86509991e-01 1.01190643e+00 1.79531051 0.38768743 319.00 -4.86578586e-02 8.89406948e-01 8.90736946e-01 1.62545005 0.28635166 319.25 4.36580128e-01 9.22989671e-01 1.02103484e+00 1.12897575 0.43957093 319.50 7.05195103e-01 8.32234684e-01 1.09083211e+00 0.86784201 0.43522987 319.75 8.43949792e-01 6.14854068e-01 1.04417277e+00 0.62962689 0.37589392 320.00 7.91414864e-01 5.38070367e-01 9.57004288e-01 0.59709739 0.39006840 320.25 6.36333531e-01 6.06564976e-01 8.79114004e-01 0.76145183 0.50634628 320.50 7.34565614e-01 6.18788208e-01 9.60461080e-01 0.70005744 0.49277282 320.75 7.22943202e-01 6.89906281e-01 9.99308536e-01 0.76201924 0.51867605 321.00 8.82346821e-01 5.46872533e-01 1.03807778e+00 0.55484631 0.45536423 321.25 1.15119680e+00 3.50797392e-01 1.20345872e+00 0.29578516 0.55274514 321.50 1.09788734e+00 1.34194176e-02 1.09796935e+00 0.01222234 0.44175785 321.75 9.54011913e-01 -6.04823260e-01 1.12957953e+00 -0.56502989 0.53596629 322.00 6.20113235e-01 -6.29725904e-01 8.83795869e-01 -0.79308914 0.39998506 322.25 2.94897484e-01 -6.65595650e-01 7.27998692e-01 -1.15373034 0.40711402 322.50 6.96375076e-02 -6.52976571e-01 6.56679362e-01 -1.46455164 0.38378465 322.75 -7.61871924e-02 -4.73012143e-01 4.79108522e-01 -1.73049291 0.31382993 323.00 -1.78137452e-01 -3.45870717e-01 3.89049489e-01 -2.04640387 0.23747817 323.25 -1.51600368e-01 -3.17816734e-01 3.52122348e-01 -2.01587980 0.32575081 323.50 -2.35108854e-01 -2.34457982e-01 3.32034213e-01 -2.35758060 0.28122804 323.75 -2.83276908e-01 -1.45343751e-01 3.18387520e-01 -2.66753579 0.35164763 324.00 -2.79004610e-01 -9.77519613e-02 2.95633249e-01 -2.80459746 0.27562560 324.25 -2.54605940e-01 -7.47141145e-02 2.65342013e-01 -2.85615581 0.29058978 324.50 -2.46012893e-01 -2.89005094e-02 2.47704628e-01 -3.02465304 0.16770270 324.75 -2.19882132e-01 -3.43449315e-02 2.22548256e-01 -2.98664764 0.17467410 325.00 -2.21452831e-01 1.02231468e-02 2.21688676e-01 3.09546141 0.17270882 325.25 -1.89432831e-01 5.29003948e-02 1.96680577e-01 2.86927331 0.18555511 325.50 -9.00519810e-02 1.17865510e-01 1.48329490e-01 2.22321202 0.08043219 325.75 -1.36497658e-01 1.34880250e-01 1.91896567e-01 2.36215440 0.12296758 326.00 -8.64625414e-02 1.28119379e-01 1.54565023e-01 2.16444926 0.07293885 326.25 -8.52699355e-02 8.87367610e-02 1.23065733e-01 2.33627361 0.05708328 326.50 -1.33462428e-01 2.00945268e-01 2.41228564e-01 2.15707058 0.16551658 326.75 -1.06195600e-01 1.64002970e-01 1.95382905e-01 2.14542786 0.12153920 327.00 3.51093847e-03 7.98785164e-02 7.99556382e-02 1.52687112 0.02856990 327.25 3.95350676e-02 5.94204957e-02 7.13709806e-02 0.98371001 0.02555745 327.50 1.99905405e-02 2.55128861e-02 3.24118661e-02 0.90616864 0.00415886 327.75 4.10554770e-03 1.96729895e-02 2.00968166e-02 1.36505954 0.00141055 328.00 -4.69400115e-02 1.44839206e-01 1.52255576e-01 1.88419915 0.05531080 328.25 -7.52669475e-02 1.27201791e-01 1.47801925e-01 2.10510013 0.05581200 328.50 -1.51531857e-01 6.04605637e-02 1.63148348e-01 2.76195233 0.06124652 328.75 -9.38147669e-02 7.35323173e-02 1.19198205e-01 2.47680611 0.03356944 329.00 -4.66973662e-02 1.37248897e-01 1.44975528e-01 1.89874865 0.06997714 329.25 -1.23472203e-02 1.31243066e-01 1.31822594e-01 1.66459926 0.05760080 329.50 -5.56954784e-02 9.40717892e-02 1.09322861e-01 2.10535190 0.03257669 329.75 -4.56043078e-02 1.03207447e-01 1.12834082e-01 1.98686908 0.02689112 330.00 -1.11536853e-01 4.46068209e-02 1.20125926e-01 2.76114750 0.03076294 330.25 -1.50819968e-01 3.45819883e-02 1.54733890e-01 2.91619569 0.04608420 330.50 -2.26750462e-01 1.74717530e-01 2.86255109e-01 2.48508269 0.19001840 330.75 -1.19973654e-01 2.05535298e-01 2.37988311e-01 2.09915411 0.12974168 331.00 -8.37583575e-02 1.38828760e-01 1.62138481e-01 2.11365443 0.08403867 331.25 5.28678466e-02 8.82278278e-02 1.02855038e-01 1.03095082 0.02496708 331.50 2.13872318e-01 2.54311877e-02 2.15379000e-01 0.11835256 0.11151197 331.75 2.33004413e-01 -3.72747855e-02 2.35967087e-01 -0.15863049 0.15787550 332.00 2.11922190e-01 -1.77805133e-02 2.12666785e-01 -0.08370510 0.21227236 332.25 1.91925641e-01 -1.29777154e-01 2.31684185e-01 -0.59456300 0.15517166 332.50 4.18307710e-01 -2.27382204e-01 4.76113439e-01 -0.49789810 0.42942373 332.75 3.28803277e-01 -2.68374229e-01 4.24424695e-01 -0.68455034 0.32077115 333.00 1.70509757e-01 -3.58812245e-01 3.97265408e-01 -1.12717987 0.32705619 333.25 1.97611640e-01 -4.55749557e-01 4.96747440e-01 -1.16166654 0.32372093 333.50 1.69565414e-01 -6.55052991e-01 6.76643814e-01 -1.31749867 0.46865367 333.75 -6.08125864e-02 -7.00100167e-01 7.02736376e-01 -1.65744154 0.30040959 334.00 -2.29425241e-01 -6.48678498e-01 6.88055038e-01 -1.91074664 0.30130795 334.25 -2.49578195e-01 -4.58003903e-01 5.21590692e-01 -2.06973554 0.17884351 334.50 -1.17127469e-01 -4.21413886e-01 4.37388280e-01 -1.84189310 0.20093884 334.75 -3.54237558e-02 -3.47748829e-01 3.49548410e-01 -1.67231209 0.09178052 335.00 6.18378795e-02 -6.04766978e-01 6.07920242e-01 -1.46889971 0.26167502 335.25 1.95997085e-01 -7.00419264e-01 7.27325239e-01 -1.29794691 0.21970602 335.50 3.38176155e-01 -9.55890602e-01 1.01394771e+00 -1.23075691 0.25380272 335.75 -8.47282086e-02 -9.37126286e-01 9.40948748e-01 -1.66096397 0.12148975 336.00 -3.77359531e-01 -8.04600399e-01 8.88696808e-01 -2.00933981 0.08231005 336.25 -5.97360019e-01 -8.77358387e-01 1.06141261e+00 -2.16856222 0.07629732 336.50 -8.36442606e-01 -1.09748082e+00 1.37989144e+00 -2.22202681 0.09959502 336.75 -1.66991499e+00 3.83231349e-01 1.71332493e+00 2.91600724 0.10045425 337.00 -1.90833766e+00 1.48015573e+00 2.41508046e+00 2.48189179 0.16772288 337.25 -5.85767424e-01 2.62691950e+00 2.69143634e+00 1.79019341 0.26707990 337.50 8.10659192e-02 2.46228199e+00 2.46361610e+00 1.53788513 0.29187772 337.75 4.14235455e-01 1.96716126e+00 2.01030208e+00 1.36325325 0.33170768 338.00 6.52480666e-01 1.97058185e+00 2.07579475e+00 1.25104751 0.45490899 338.25 1.08482020e+00 1.78033512e+00 2.08480887e+00 1.02354124 0.54617765 338.50 1.11999375e+00 1.57340318e+00 1.93131654e+00 0.95217559 0.56886647 338.75 7.49863256e-01 9.44914017e-01 1.20629905e+00 0.89998334 0.50191477 339.00 6.46511691e-01 8.09006565e-01 1.03560079e+00 0.89657835 0.52351690 339.25 6.22247638e-01 8.87344039e-01 1.08377653e+00 0.95923372 0.60847548 339.50 5.69756984e-01 8.51364069e-01 1.02442364e+00 0.98102234 0.56565309 339.75 3.98694866e-01 8.31548925e-01 9.22188273e-01 1.12371492 0.57600758 340.00 4.20131138e-01 7.00403543e-01 8.16746776e-01 1.03049335 0.49038907 340.25 3.62104141e-01 6.65203759e-01 7.57374049e-01 1.07230072 0.59114182 340.50 4.19107769e-01 5.60729313e-01 7.00049059e-01 0.92893992 0.51165040 340.75 3.45067989e-01 5.04374123e-01 6.11117970e-01 0.97078676 0.41751005 341.00 3.65508782e-01 3.68225910e-01 5.18832334e-01 0.78910129 0.32949589 341.25 3.36754622e-01 2.65348254e-01 4.28734617e-01 0.66735456 0.34404594 341.50 2.80642465e-01 2.68771790e-01 3.88585213e-01 0.76379547 0.22623957 341.75 1.45312223e-01 1.77911687e-01 2.29713323e-01 0.88591547 0.12515052 342.00 9.13567823e-02 1.08833766e-01 1.42094512e-01 0.87247912 0.04271128 342.25 1.63204104e-01 6.41677649e-02 1.75365566e-01 0.37460890 0.09011158 342.50 1.90842337e-01 7.43585066e-02 2.04816955e-01 0.37153764 0.09172606 342.75 1.39117739e-01 1.32745197e-01 1.92288930e-01 0.76196218 0.08806552 343.00 -3.52865292e-02 -4.80995565e-02 5.96548948e-02 -2.20372794 0.00590294 343.25 -5.78772220e-02 -2.66792044e-01 2.72997743e-01 -1.78442373 0.16426021 343.50 -8.05086539e-02 -1.66718038e-01 1.85139265e-01 -2.02067309 0.06354080 343.75 -1.09640675e-01 -1.31034883e-01 1.70854377e-01 -2.26753521 0.05801460 344.00 -9.48158988e-02 -2.83593957e-01 2.99024392e-01 -1.89344974 0.12953453 344.25 -2.13327742e-02 -3.56608759e-01 3.57246266e-01 -1.63054635 0.21945068 344.50 -1.34043389e-01 -5.33588848e-01 5.50167874e-01 -1.81691443 0.31552484 344.75 -2.59777772e-01 -6.52332719e-01 7.02155586e-01 -1.94977500 0.56278381 345.00 -5.49861792e-01 -7.65753018e-01 9.42722481e-01 -2.19354501 0.63582478 345.25 -6.49719165e-01 -8.46592449e-01 1.06717092e+00 -2.22537355 0.76220726 345.50 -7.38154383e-01 -8.01446715e-01 1.08958191e+00 -2.31510806 0.70755866 345.75 -8.79514826e-01 -8.63887223e-01 1.23282094e+00 -2.36515811 0.79182109 346.00 -1.07240210e+00 -9.90654556e-01 1.45994614e+00 -2.39579825 0.83069402 346.25 -1.18719204e+00 -1.02541302e+00 1.56872457e+00 -2.42918160 0.87880506 346.50 -1.27578027e+00 -9.57640131e-01 1.59520843e+00 -2.49768787 0.90508118 346.75 -1.30541509e+00 -9.75789235e-01 1.62980771e+00 -2.49969766 0.91940158 347.00 -1.43061856e+00 -1.15647828e+00 1.83959547e+00 -2.46176498 0.86539143 347.25 -1.47477864e+00 -1.29460460e+00 1.96238964e+00 -2.42116220 0.87471361 347.50 -1.72569916e+00 -1.51797143e+00 2.29832001e+00 -2.42014810 0.89445835 347.75 -1.90055260e+00 -1.67021065e+00 2.53015885e+00 -2.42061300 0.91004090 348.00 -2.07763790e+00 -2.09275402e+00 2.94893177e+00 -2.35256988 0.89277537 348.25 -2.44701424e+00 -2.22022556e+00 3.30413078e+00 -2.40474791 0.88109264 348.50 -3.20517567e+00 -2.65529500e+00 4.16218004e+00 -2.44974934 0.88718546 348.75 -3.68226896e+00 -2.88521513e+00 4.67798793e+00 -2.47696749 0.91418692 349.00 -4.32789984e+00 -2.89300063e+00 5.20578234e+00 -2.55235390 0.89104899 349.25 -5.14183712e+00 -2.90638172e+00 5.90639853e+00 -2.62712278 0.91084684 349.50 -5.73988134e+00 -2.64314235e+00 6.31921192e+00 -2.71005181 0.91538788 349.75 -6.34498945e+00 -2.40722136e+00 6.78628071e+00 -2.77897936 0.90329091 350.00 -7.56021772e+00 -1.57434266e+00 7.72239903e+00 -2.93628635 0.92066283 350.25 -7.86461213e+00 -1.39805243e+00 7.98790802e+00 -2.96566546 0.93007488 350.50 -8.37436448e+00 -1.34525949e+00 8.48172762e+00 -2.98231325 0.95552133 350.75 -8.50157253e+00 -1.19817121e+00 8.58558965e+00 -3.00157956 0.93858811 351.00 -8.98158151e+00 -1.07110787e+00 9.04522407e+00 -3.02289719 0.93233931 351.25 -9.76913286e+00 -5.19101134e-01 9.78291484e+00 -3.08850571 0.91878959 351.50 -1.09385070e+01 4.34135170e-01 1.09471187e+01 3.10192477 0.92265419 351.75 -1.11552362e+01 1.48054882e+00 1.12530582e+01 3.00964151 0.87159209 352.00 -1.13667362e+01 2.63578264e+00 1.16683350e+01 2.91373413 0.88207814 352.25 -1.12688687e+01 3.04458457e+00 1.16729129e+01 2.87771623 0.86635853 352.50 -1.13638899e+01 3.81596941e+00 1.19874775e+01 2.81762571 0.89387033 352.75 -1.10025477e+01 3.62825474e+00 1.15853480e+01 2.82305706 0.88114264 353.00 -1.10157749e+01 2.59225834e+00 1.13166735e+01 2.91047521 0.90254297 353.25 -1.21043595e+01 2.36670860e+00 1.23335651e+01 2.94850336 0.84447905 353.50 -1.47736143e+01 2.16595809e+00 1.49315456e+01 2.99601985 0.82356401 353.75 -1.57232495e+01 2.84522766e+00 1.59786075e+01 2.96257318 0.70214571 354.00 -1.96013676e+01 6.29831312e+00 2.05884035e+01 2.83069270 0.70858075 354.25 -2.08620406e+01 1.05268317e+01 2.33674758e+01 2.67427770 0.72296946 354.50 -2.37047416e+01 1.41403443e+01 2.76018860e+01 2.60373616 0.74375683 354.75 -2.16388394e+01 2.19253124e+01 3.08051731e+01 2.34961870 0.69918863 355.00 -1.99689308e+01 3.29959642e+01 3.85680159e+01 2.11502556 0.77737608 355.25 -1.35290317e-01 3.72807543e+01 3.72809998e+01 1.57442527 0.73664141 355.50 1.43298868e+01 3.58882664e+01 3.86434124e+01 1.19090071 0.76905041 355.75 2.16291888e+01 1.87824081e+01 2.86461282e+01 0.71506970 0.66372404 356.00 2.19442548e+01 1.03194649e+01 2.42495706e+01 0.43957232 0.78017382 356.25 1.63777504e+01 2.05822929e+00 1.65065749e+01 0.12501688 0.74033734 356.50 1.22075101e+01 -4.23761261e-01 1.22148629e+01 -0.03469923 0.80233222 356.75 7.87098534e+00 -1.45186022e+00 8.00376839e+00 -0.18240692 0.79990775 357.00 6.23120250e+00 -1.33274092e+00 6.37213332e+00 -0.21070714 0.87342466 357.25 4.25424002e+00 -9.70049384e-01 4.36343374e+00 -0.22418651 0.84377320 357.50 3.33319001e+00 -6.12066521e-01 3.38892034e+00 -0.18160470 0.84355029 357.75 2.68630816e+00 -7.77898624e-02 2.68743424e+00 -0.02894982 0.75212422 358.00 2.18538599e+00 -1.60744591e-01 2.19128975e+00 -0.07342210 0.55952446 358.25 4.88658059e-01 -9.16409543e-01 1.03855339e+00 -1.08091861 0.28012130 358.50 1.55912262e-01 -7.61508587e-01 7.77305578e-01 -1.36884600 0.29403697 358.75 -1.78064151e-01 -4.57444409e-01 4.90879037e-01 -1.94200868 0.27886738 359.00 -3.22657395e-01 -3.71085176e-01 4.91743838e-01 -2.28650099 0.34292672 359.25 -5.53004662e-01 -1.30450929e-01 5.68182718e-01 -2.90993288 0.42627565 359.50 -6.63393776e-01 -1.67877829e-02 6.63606157e-01 -3.11629214 0.55526109 359.75 -7.61629294e-01 1.42380973e-01 7.74823543e-01 2.95678321 0.70339909 360.00 -6.75557370e-01 1.78886031e-01 6.98840448e-01 2.88273597 0.70695196 360.25 -6.89538611e-01 1.91372401e-01 7.15602467e-01 2.87086945 0.75976347 360.50 -6.73751267e-01 1.84035095e-01 6.98433738e-01 2.87494727 0.76133990 360.75 -6.28496880e-01 1.82209543e-01 6.54376532e-01 2.85941530 0.75320209 361.00 -6.03427533e-01 1.93755613e-01 6.33771272e-01 2.83089967 0.69199122 361.25 -4.47621675e-01 2.88751474e-01 5.32674927e-01 2.56868441 0.59651189 361.50 -3.17056743e-01 1.81309640e-01 3.65237134e-01 2.62212714 0.29939402 361.75 -1.32690388e-01 -1.09696367e-01 1.72162807e-01 -2.45077645 0.09977690 362.00 -2.03605328e-01 -2.24646920e-01 3.03185369e-01 -2.30710033 0.27764966 362.25 -1.68179707e-01 -3.17558015e-01 3.59343160e-01 -2.05784499 0.44863711 362.50 -1.46753047e-01 -4.24138237e-01 4.48809204e-01 -1.90390580 0.44043094 362.75 -2.32360500e-01 -6.28657442e-01 6.70225023e-01 -1.92483656 0.73687070 363.00 -3.20767280e-01 -7.14104966e-01 7.82839415e-01 -1.99297467 0.79408187 363.25 -4.27218504e-01 -7.83004635e-01 8.91970800e-01 -2.07026614 0.87867645 363.50 -5.16300365e-01 -7.49938378e-01 9.10479894e-01 -2.17373326 0.88013386 363.75 -5.47662811e-01 -6.81746026e-01 8.74478244e-01 -2.24756070 0.91110563 364.00 -5.00713944e-01 -6.70392343e-01 8.36743896e-01 -2.21230847 0.91322147 364.25 -4.47397368e-01 -6.86451160e-01 8.19377569e-01 -2.14840368 0.93981593 364.50 -4.34996562e-01 -7.17222303e-01 8.38826466e-01 -2.11598280 0.92254357 364.75 -4.52448832e-01 -7.26145219e-01 8.55568130e-01 -2.12801603 0.93475054 365.00 -4.81129865e-01 -7.30744698e-01 8.74913573e-01 -2.15306121 0.92539598 365.25 -4.71567446e-01 -7.01533455e-01 8.45295832e-01 -2.16261664 0.93790394 365.50 -3.67094458e-01 -6.65116937e-01 7.59696572e-01 -2.07511602 0.90689580 365.75 -3.02272350e-01 -6.55592510e-01 7.21921126e-01 -2.00281571 0.91951006 366.00 -2.44691220e-01 -7.54700285e-01 7.93376527e-01 -1.88432533 0.87661323 366.25 -2.20189353e-01 -8.74639647e-01 9.01930077e-01 -1.81742010 0.93191013 366.50 -2.04024439e-01 -9.35286959e-01 9.57281394e-01 -1.78557277 0.94791094 366.75 -2.02874864e-01 -9.76101196e-01 9.96961260e-01 -1.77572081 0.96333318 367.00 -2.09934716e-01 -1.00893071e+00 1.03054052e+00 -1.77594550 0.95222700 367.25 -2.03031273e-01 -1.00592409e+00 1.02620903e+00 -1.76995624 0.95627018 367.50 -1.48177183e-01 -1.02990880e+00 1.04051363e+00 -1.71368984 0.93735190 367.75 -7.99650645e-02 -1.08129232e+00 1.08424513e+00 -1.64461518 0.93969142 368.00 -1.63472061e-01 -1.32201482e+00 1.33208345e+00 -1.69382554 0.93208300 368.25 -1.94683825e-01 -1.45262851e+00 1.46561638e+00 -1.70402420 0.95403827 368.50 -1.75757567e-01 -1.57150268e+00 1.58130054e+00 -1.68217393 0.95110503 368.75 -2.26819829e-01 -1.65303747e+00 1.66852633e+00 -1.70715875 0.94753787 369.00 -4.56095396e-01 -1.68400296e+00 1.74467446e+00 -1.83529094 0.91951570 369.25 -6.28854343e-01 -1.63511166e+00 1.75186984e+00 -1.93795164 0.92328949 369.50 -5.82561022e-01 -1.54459722e+00 1.65080524e+00 -1.93145977 0.90854400 369.75 -5.02052405e-01 -1.53569082e+00 1.61567414e+00 -1.88676638 0.91686976 370.00 -6.55162207e-01 -1.53710192e+00 1.67090389e+00 -1.97371013 0.93543579 370.25 -7.39823408e-01 -1.44583726e+00 1.62412563e+00 -2.04375375 0.93212695 370.50 -5.71136120e-01 -1.40608711e+00 1.51765524e+00 -1.95662603 0.94781247 370.75 -4.68599103e-01 -1.43453098e+00 1.50912699e+00 -1.88652589 0.94161112 371.00 -4.87801614e-01 -1.56169730e+00 1.63610785e+00 -1.87354772 0.96564006 371.25 -4.24645399e-01 -1.71423533e+00 1.76604827e+00 -1.81362522 0.96091101 371.50 -3.46817470e-01 -1.92780052e+00 1.95874889e+00 -1.74879550 0.95948055 371.75 -4.79031931e-01 -2.08458026e+00 2.13891245e+00 -1.79667265 0.94490772 372.00 -7.39612490e-01 -2.29798874e+00 2.41407930e+00 -1.88217842 0.95674318 372.25 -9.96367898e-01 -2.37362199e+00 2.57426307e+00 -1.96822614 0.94829649 372.50 -1.53563906e+00 -2.43300127e+00 2.87709619e+00 -2.13382068 0.94909452 372.75 -1.89037042e+00 -2.35720909e+00 3.02157823e+00 -2.24672687 0.95675312 373.00 -2.19841116e+00 -2.01914943e+00 2.98495830e+00 -2.39867258 0.94879190 373.25 -2.20312185e+00 -1.52121455e+00 2.67728213e+00 -2.53728365 0.95433534 373.50 -2.11770134e+00 -1.21017895e+00 2.43909657e+00 -2.62242379 0.97697104 373.75 -1.96385533e+00 -9.64996072e-01 2.18813738e+00 -2.68486609 0.97496167 374.00 -1.81448989e+00 -8.00355300e-01 1.98316469e+00 -2.72617204 0.98681166 374.25 -1.70409400e+00 -6.91463209e-01 1.83903717e+00 -2.75612559 0.98994380 374.50 -1.57546456e+00 -6.15387896e-01 1.69138726e+00 -2.76920960 0.98714790 374.75 -1.40488162e+00 -5.53686581e-01 1.51005338e+00 -2.76616880 0.97491396 375.00 -1.22103498e+00 -5.51592783e-01 1.33984365e+00 -2.71729102 0.97254393 375.25 -1.02153817e+00 -6.42547644e-01 1.20681718e+00 -2.58012201 0.94478372 375.50 -8.71453892e-01 -7.75558221e-01 1.16658581e+00 -2.41435285 0.95687815 375.75 -8.94507897e-01 -9.47757904e-01 1.30322271e+00 -2.32729791 0.96355861 376.00 -9.72081678e-01 -1.05257678e+00 1.43278075e+00 -2.31645804 0.97204431 376.25 -1.03877480e+00 -1.06813886e+00 1.48995762e+00 -2.34225839 0.97720499 376.50 -1.03569862e+00 -1.07804258e+00 1.49494061e+00 -2.33616446 0.98527524 376.75 -1.06104504e+00 -1.13244288e+00 1.55185162e+00 -2.32365606 0.98048127 377.00 -1.11350181e+00 -1.19917440e+00 1.63643073e+00 -2.31916664 0.98113601 377.25 -1.26054105e+00 -1.14698886e+00 1.70427321e+00 -2.40332500 0.98118922 377.50 -1.32377654e+00 -1.07633014e+00 1.70612746e+00 -2.45892960 0.98392958 377.75 -1.25263949e+00 -8.99513461e-01 1.54215115e+00 -2.51882571 0.97764003 378.00 -1.16428978e+00 -8.16082999e-01 1.42181650e+00 -2.53024432 0.97728178 378.25 -9.72156623e-01 -7.44638964e-01 1.22457163e+00 -2.48795134 0.95006198 378.50 -8.11489748e-01 -8.08706781e-01 1.14565364e+00 -2.35791216 0.95273246 378.75 -6.65835781e-01 -9.37059461e-01 1.14952935e+00 -2.18857359 0.94506422 379.00 -5.77591785e-01 -1.06471653e+00 1.21129417e+00 -2.06785086 0.95302007 379.25 -5.58120104e-01 -1.22111347e+00 1.34261542e+00 -1.99950445 0.96115502 379.50 -5.65740694e-01 -1.30482779e+00 1.42219482e+00 -1.97990759 0.96367009 379.75 -5.43429698e-01 -1.46141833e+00 1.55918549e+00 -1.92680327 0.95911227 380.00 -5.82189281e-01 -1.50160320e+00 1.61051437e+00 -1.94066475 0.95984114 380.25 -5.32944206e-01 -1.55086312e+00 1.63987986e+00 -1.90179726 0.96697856 380.50 -4.84232214e-01 -1.60417807e+00 1.67566946e+00 -1.86395582 0.96174386 380.75 -2.53210828e-01 -1.85404519e+00 1.87125607e+00 -1.70652868 0.96039531 381.00 -1.29251957e-01 -2.03877087e+00 2.04286385e+00 -1.63410860 0.94935067 381.25 -7.08183086e-03 -2.49561667e+00 2.49562672e+00 -1.57363403 0.95923969 381.50 -5.53426012e-02 -2.77418806e+00 2.77474002e+00 -1.59074280 0.94417449 381.75 -2.27888742e-01 -3.49065464e+00 3.49808563e+00 -1.63598920 0.93480441 382.00 -5.33058555e-01 -4.01972107e+00 4.05491171e+00 -1.70263791 0.90196436 382.25 -1.60574960e+00 -5.14479947e+00 5.38956337e+00 -1.87332696 0.92994092 382.50 -2.67210997e+00 -5.25106371e+00 5.89184537e+00 -2.04151491 0.91911837 382.75 -4.39322960e+00 -4.82113113e+00 6.52255868e+00 -2.30978928 0.93591656 383.00 -5.43757438e+00 -4.10684288e+00 6.81420382e+00 -2.49472656 0.92274249 383.25 -6.51779172e+00 -2.47395295e+00 6.97151721e+00 -2.77882214 0.93116897 383.50 -6.34246120e+00 -1.11118323e+00 6.43906377e+00 -2.96815538 0.93763740 383.75 -5.73981733e+00 -1.96552171e-01 5.74318167e+00 -3.10736240 0.96557258 384.00 -5.09142667e+00 1.13291337e-01 5.09268696e+00 3.11934493 0.96018154 384.25 -4.54338891e+00 3.43678653e-01 4.55636893e+00 3.06609276 0.97621354 384.50 -4.08728228e+00 5.18024996e-01 4.11997892e+00 3.01552411 0.96972111 384.75 -3.73503769e+00 6.28164007e-01 3.78749212e+00 2.97497051 0.98330048 385.00 -3.56342170e+00 5.05879494e-01 3.59915105e+00 3.00057047 0.97963770 385.25 -3.43810362e+00 4.89256144e-01 3.47274072e+00 3.00023765 0.98185991 385.50 -3.33194725e+00 5.73062339e-01 3.38086866e+00 2.97126882 0.97119668 385.75 -3.26311038e+00 6.62823724e-01 3.32974843e+00 2.94119280 0.97905476 386.00 -3.17954603e+00 6.71851652e-01 3.24975347e+00 2.93335161 0.98047534 386.25 -3.14897241e+00 7.07154363e-01 3.22739749e+00 2.92069066 0.98394003 386.50 -3.09067557e+00 6.71253005e-01 3.16272921e+00 2.92772754 0.96672305 386.75 -3.12234162e+00 6.53559467e-01 3.19000896e+00 2.93525461 0.96540467 387.00 -3.12261000e+00 8.47544924e-01 3.23558737e+00 2.87655595 0.97112834 387.25 -3.03720307e+00 9.41004212e-01 3.17963699e+00 2.84114582 0.97805559 387.50 -2.84120807e+00 1.18879233e+00 3.07988482e+00 2.74531627 0.96746111 387.75 -2.72116926e+00 1.24893031e+00 2.99409236e+00 2.71130580 0.97684928 388.00 -2.57928131e+00 1.25314988e+00 2.86759075e+00 2.68932709 0.97548926 388.25 -2.52599511e+00 1.28327479e+00 2.83327469e+00 2.67154375 0.98158945 388.50 -2.48522926e+00 1.31149127e+00 2.81004873e+00 2.65602013 0.97947296 388.75 -2.43961927e+00 1.35315164e+00 2.78976012e+00 2.63518112 0.98067549 389.00 -2.35162642e+00 1.45207864e+00 2.76381606e+00 2.58842038 0.97971304 389.25 -2.25337600e+00 1.52744068e+00 2.72227449e+00 2.54589076 0.98180623 389.50 -2.11692973e+00 1.66903719e+00 2.69575159e+00 2.47395051 0.97444585 389.75 -1.98742567e+00 1.72444016e+00 2.63126484e+00 2.42692625 0.97539334 390.00 -1.66598525e+00 1.73450237e+00 2.40499591e+00 2.33604801 0.97969044 390.25 -1.56274443e+00 1.71853189e+00 2.32282630e+00 2.30875241 0.98018685 390.50 -1.37214704e+00 1.56964792e+00 2.08484582e+00 2.28915890 0.97116826 390.75 -1.30848524e+00 1.51422457e+00 2.00125203e+00 2.28343598 0.97601661 391.00 -1.20591103e+00 1.45788499e+00 1.89199632e+00 2.26188305 0.96875550 391.25 -1.15149732e+00 1.33636239e+00 1.76403246e+00 2.28202393 0.96228062 391.50 -1.09388147e+00 1.17586104e+00 1.60599684e+00 2.32009174 0.96326190 391.75 -1.04211745e+00 1.09622183e+00 1.51251812e+00 2.33089783 0.95508555 392.00 -1.07749548e+00 9.62716156e-01 1.44492868e+00 2.41239379 0.95620905 392.25 -1.15825848e+00 9.36549448e-01 1.48952596e+00 2.46163935 0.95184045 392.50 -1.21478466e+00 1.07951007e+00 1.62512884e+00 2.41508760 0.95942277 392.75 -1.22113982e+00 1.15426748e+00 1.68033207e+00 2.38433901 0.95331134 393.00 -1.14932844e+00 1.27667471e+00 1.71780505e+00 2.30375041 0.92664654 393.25 -9.96563733e-01 1.40418980e+00 1.72188509e+00 2.18800758 0.92497020 393.50 -6.54993976e-01 1.49075440e+00 1.62830151e+00 1.98477595 0.91691654 393.75 -4.00518498e-01 1.21885403e+00 1.28297320e+00 1.88828312 0.81677747 394.00 -1.58616697e-01 8.70162688e-01 8.84501193e-01 1.75110066 0.72877253 394.25 -1.15674689e-01 5.53150294e-01 5.65115813e-01 1.77694537 0.49994374 394.50 -1.90865765e-01 1.40258324e-01 2.36858898e-01 2.50785616 0.16133315 394.75 -4.77072070e-01 7.72496439e-03 4.77134609e-01 3.12540162 0.48133566 395.00 -7.40333541e-01 -1.18637982e-01 7.49779116e-01 -2.98269426 0.70607077 395.25 -9.21963844e-01 -2.73318697e-01 9.61623855e-01 -2.85339341 0.66553324 395.50 -1.60555833e+00 -2.29667192e-01 1.62190153e+00 -2.99951144 0.81622951 395.75 -1.76086095e+00 3.13208695e-01 1.78849964e+00 2.96556123 0.83278047 396.00 -1.67278843e+00 9.21399010e-01 1.90976366e+00 2.63812300 0.82024739 396.25 -1.15668194e+00 1.20324737e+00 1.66904684e+00 2.33646535 0.83909227 396.50 -8.91147280e-01 1.16913133e+00 1.47003794e+00 2.22207896 0.88440623 396.75 -7.99800748e-01 7.99226874e-01 1.13068335e+00 2.35655338 0.86029916 397.00 -8.43615893e-01 6.21736922e-01 1.04797165e+00 2.50646973 0.88978538 397.25 -1.01188695e+00 5.72513566e-01 1.16262074e+00 2.62670894 0.87310647 397.50 -1.19611809e+00 6.37032755e-01 1.35517866e+00 2.65221929 0.91016796 397.75 -1.26398972e+00 8.96134496e-01 1.54942797e+00 2.52486994 0.92836771 398.00 -1.15000331e+00 1.00347237e+00 1.52625830e+00 2.42413370 0.94310666 398.25 -8.69707157e-01 9.60501172e-01 1.29574420e+00 2.30662656 0.94627597 398.50 -7.51166617e-01 9.25508792e-01 1.19198063e+00 2.25258595 0.94882045 398.75 -6.70156793e-01 8.02535290e-01 1.04554915e+00 2.26654664 0.95055536 399.00 -6.58212534e-01 7.73233268e-01 1.01544740e+00 2.27601392 0.96297644 399.25 -6.58869008e-01 6.76333242e-01 9.44211324e-01 2.34311539 0.95503380 399.50 -6.56409301e-01 6.52203478e-01 9.25333749e-01 2.35940843 0.96334902 399.75 -6.27513080e-01 5.73466014e-01 8.50079958e-01 2.40116665 0.96182652 400.00 -6.28234369e-01 5.46339748e-01 8.32565639e-01 2.42580466 0.96546425 400.25 -5.90686148e-01 5.20724102e-01 7.87441246e-01 2.41906043 0.94501772 400.50 -5.50108288e-01 4.57154073e-01 7.15268464e-01 2.44821786 0.93523473 400.75 -5.10456455e-01 3.64064615e-01 6.26983921e-01 2.52205327 0.90561963 401.00 -4.95322664e-01 2.65845866e-01 5.62155287e-01 2.64900818 0.87088975 401.25 -5.28863049e-01 3.49514324e-02 5.30016723e-01 3.07560075 0.82013471 401.50 -6.08637996e-01 -7.42538215e-02 6.13150749e-01 -3.02019261 0.81385783 401.75 -8.77693169e-01 -2.24575584e-01 9.05968814e-01 -2.89109671 0.87281329 402.00 -1.06236736e+00 -3.25333398e-01 1.11106536e+00 -2.84442611 0.88415760 402.25 -1.51792490e+00 -3.15471039e-01 1.55036059e+00 -2.93667926 0.92910248 402.50 -1.65746313e+00 -2.48699255e-01 1.67601771e+00 -2.99265563 0.92221853 402.75 -2.02841113e+00 2.87498143e-01 2.04868419e+00 3.00079485 0.90033453 403.00 -2.13020713e+00 6.25878643e-01 2.22024920e+00 2.85582331 0.91968090 403.25 -1.95990628e+00 1.17944921e+00 2.28742935e+00 2.59985906 0.93903920 403.50 -1.79777160e+00 1.35392705e+00 2.25057797e+00 2.49610153 0.93071277 403.75 -1.54298062e+00 1.77210296e+00 2.34971022e+00 2.28718912 0.94307200 404.00 -1.24774527e+00 1.87449789e+00 2.25180163e+00 2.15808948 0.91864270 404.25 -6.40122951e-01 1.79919872e+00 1.90967888e+00 1.91261305 0.91848984 404.50 -3.78403135e-01 1.68215756e+00 1.72419343e+00 1.79206419 0.88894485 404.75 -5.66113092e-02 1.39283334e+00 1.39398334e+00 1.61141868 0.86049301 405.00 2.08023133e-02 9.46516521e-01 9.46745088e-01 1.54882210 0.73770561 405.25 3.46107772e-02 6.33920623e-01 6.34864759e-01 1.51625251 0.69216746 405.50 -1.21155677e-01 5.96815892e-01 6.08989251e-01 1.77107813 0.53088979 405.75 -3.76359132e-01 7.05413409e-01 7.99533785e-01 2.06090666 0.70915761 406.00 -3.99426677e-01 8.21689718e-01 9.13627748e-01 2.02326548 0.82252515 406.25 -3.35119137e-01 8.23059758e-01 8.88668780e-01 1.95746205 0.88503702 406.50 -2.38226734e-01 8.49813218e-01 8.82572650e-01 1.84410948 0.87282148 406.75 -1.34040324e-01 8.60192750e-01 8.70573590e-01 1.72537907 0.90465788 407.00 -1.73332140e-02 7.68011221e-01 7.68206793e-01 1.59336146 0.86510926 407.25 3.34849073e-02 6.91701989e-01 6.92512008e-01 1.52242465 0.86992301 407.50 6.93459298e-02 5.31256067e-01 5.35762883e-01 1.44099818 0.76438011 407.75 7.02027919e-02 4.25503410e-01 4.31255822e-01 1.40728177 0.74001423 408.00 6.69695991e-02 3.56668075e-01 3.62900872e-01 1.38519288 0.62860016 408.25 6.44076279e-02 3.28958617e-01 3.35204586e-01 1.37744970 0.63558691 408.50 6.70418858e-02 2.59265179e-01 2.67792919e-01 1.31775485 0.35720972 408.75 6.99827565e-02 2.65255499e-01 2.74332036e-01 1.31284274 0.39684580 409.00 5.47361493e-02 2.60283851e-01 2.65976934e-01 1.36352250 0.26080377 409.25 5.76697756e-02 1.85373622e-01 1.94137021e-01 1.26918721 0.22965649 409.50 1.59824027e-01 2.07877786e-01 2.62215358e-01 0.91534846 0.30382009 409.75 2.06467030e-01 2.09786529e-01 2.94345073e-01 0.79337270 0.37679294 410.00 2.59891493e-01 4.19788426e-02 2.63259969e-01 0.16014135 0.33817787 410.25 2.86691665e-01 1.59755954e-02 2.87136432e-01 0.05566639 0.36473725 410.50 3.89782302e-01 -8.24689343e-02 3.98411054e-01 -0.20850202 0.48869804 410.75 4.22099493e-01 -1.87031293e-01 4.61680286e-01 -0.41709912 0.59749739 411.00 4.25946029e-01 -2.91795596e-01 5.16308715e-01 -0.60062381 0.65069930 411.25 4.61473149e-01 -3.61684296e-01 5.86321582e-01 -0.66475990 0.65215325 411.50 4.54949815e-01 -6.04125219e-01 7.56271522e-01 -0.92533201 0.73423130 411.75 5.00923790e-01 -6.86236839e-01 8.49614997e-01 -0.94024624 0.79895106 412.00 6.20104002e-01 -8.30633184e-01 1.03657149e+00 -0.92951090 0.81853570 412.25 6.46900538e-01 -9.71497735e-01 1.16717100e+00 -0.98333880 0.83142476 412.50 7.67865743e-01 -1.37298098e+00 1.57311620e+00 -1.06086464 0.83174424 412.75 6.36622338e-01 -1.57837407e+00 1.70192618e+00 -1.18741345 0.79143205 413.00 1.21557849e-01 -1.95937750e+00 1.96314454e+00 -1.50883672 0.75075985 413.25 -1.31346678e-01 -1.93353115e+00 1.93798727e+00 -1.63862311 0.69417566 413.50 -1.03780262e+00 -1.61334513e+00 1.91831092e+00 -2.14241978 0.71609452 413.75 -1.19736281e+00 -1.36874794e+00 1.81855674e+00 -2.28950564 0.70271395 414.00 -9.95568076e-01 -9.03573609e-01 1.34447055e+00 -2.40459668 0.63491772 414.25 -7.09117431e-01 -7.15205874e-01 1.00715787e+00 -2.35191989 0.42448196 414.50 -2.29829503e-01 -6.28282868e-01 6.68999972e-01 -1.92148205 0.21821076 414.75 -2.41898057e-01 -6.93652559e-01 7.34621360e-01 -1.90634007 0.13792695 415.00 -6.16422063e-02 -9.96304542e-01 9.98209649e-01 -1.63258841 0.22350485 415.25 -2.02456684e-01 -1.24015861e+00 1.25657554e+00 -1.73261947 0.37506614 415.50 -7.44253651e-02 -1.31064593e+00 1.31275736e+00 -1.62752067 0.55195092 415.75 -2.29053354e-01 -1.27626580e+00 1.29665718e+00 -1.74837732 0.48955972 416.00 -2.22483243e-01 -1.18556493e+00 1.20625992e+00 -1.75629894 0.55027018 416.25 -8.04116764e-02 -1.06786269e+00 1.07088597e+00 -1.64595599 0.42269938 416.50 -2.19475653e-02 -9.91482443e-01 9.91725330e-01 -1.59292882 0.49169809 416.75 3.68176242e-01 -9.93491243e-01 1.05951810e+00 -1.21589904 0.52430288 417.00 6.90071297e-01 -1.11778878e+00 1.31364004e+00 -1.01771421 0.67294799 417.25 9.87906215e-01 -1.45235662e+00 1.75650176e+00 -0.97347669 0.65386133 417.50 1.28939563e+00 -1.46565626e+00 1.95209871e+00 -0.84928833 0.76674887 417.75 1.81630407e+00 -1.53096466e+00 2.37546065e+00 -0.70035831 0.76951703 418.00 2.37116555e+00 -1.89373087e+00 3.03457454e+00 -0.67391710 0.87016901 418.25 2.95831888e+00 -2.45548905e+00 3.84461664e+00 -0.69278472 0.81069463 418.50 3.94357864e+00 -2.91636209e+00 4.90479157e+00 -0.63676122 0.88923863 418.75 4.36850715e+00 -3.54539215e+00 5.62615857e+00 -0.68176202 0.82211084 419.00 5.35929608e+00 -4.00665419e+00 6.69143724e+00 -0.64196866 0.83189503 419.25 6.92784160e+00 -5.56686066e+00 8.88734644e+00 -0.67690126 0.64803399 419.50 7.21562129e+00 -8.35290227e+00 1.10379422e+01 -0.85831866 0.57406664 419.75 4.04687437e+00 -7.77920032e+00 8.76887392e+00 -1.09110602 0.28166107 420.00 -2.99029884e+00 -8.34226365e+00 8.86201162e+00 -1.91498060 0.31680786 420.25 -6.83011277e+00 -6.51767510e+00 9.44089662e+00 -2.37959767 0.66495107 420.50 -6.10874871e+00 -7.26621409e+00 9.49287512e+00 -2.26986985 0.74101786 420.75 -5.15867961e+00 -7.68975614e+00 9.25982315e+00 -2.16169010 0.73482693 421.00 -5.26860971e+00 -8.33105426e+00 9.85721631e+00 -2.13470367 0.75852604 421.25 -6.49709793e+00 -9.73855193e+00 1.17069072e+01 -2.15913511 0.86618749 421.50 -6.76804968e+00 -9.10296497e+00 1.13433006e+01 -2.21012410 0.87660151 421.75 -6.48893508e+00 -8.78832903e+00 1.09243309e+01 -2.20680497 0.86979601 422.00 -5.90453364e+00 -8.16258142e+00 1.00742867e+01 -2.19703263 0.87936229 422.25 -4.57962108e+00 -6.82440779e+00 8.21860517e+00 -2.16183774 0.90173761 422.50 -3.11824472e+00 -7.17568393e+00 7.82393059e+00 -1.98073403 0.90233142 422.75 -4.57633774e-01 -7.92676269e+00 7.93996193e+00 -1.62846506 0.89816205 423.00 1.31433670e+00 -7.99094600e+00 8.09831458e+00 -1.40777769 0.82165454 423.25 5.71653985e+00 -7.65684657e+00 9.55542397e+00 -0.92947995 0.85002824 423.50 7.20897156e+00 -6.53646044e+00 9.73111433e+00 -0.73651099 0.78322047 423.75 1.20576021e+01 -4.14395858e+00 1.27498298e+01 -0.33103361 0.80825189 424.00 1.35767680e+01 -2.14509157e+00 1.37451827e+01 -0.15670186 0.81506318 424.25 1.26723493e+01 2.44504881e+00 1.29060723e+01 0.19060145 0.81840825 424.50 1.01999743e+01 5.10753828e+00 1.14072969e+01 0.46423968 0.78869090 424.75 8.24191470e+00 7.85811972e+00 1.13876777e+01 0.76156453 0.86456125 425.00 7.27246844e+00 9.56398515e+00 1.20149328e+01 0.92067144 0.89525421 425.25 6.38158872e+00 1.21331161e+01 1.37090182e+01 1.08659350 0.90924954 425.50 5.24971400e+00 1.20532606e+01 1.31468852e+01 1.16002961 0.88636674 425.75 5.10542581e+00 1.15517480e+01 1.26296578e+01 1.15464744 0.91354338 426.00 4.95039462e+00 1.18287432e+01 1.28228535e+01 1.17443937 0.86936408 426.25 5.01510263e+00 1.25342211e+01 1.35002945e+01 1.19019269 0.89793612 426.50 6.77873594e+00 1.08105336e+01 1.27600509e+01 1.01072482 0.87587140 426.75 7.23543187e+00 9.33492148e+00 1.18106830e+01 0.91142819 0.90447877 427.00 7.07187289e+00 7.71515228e+00 1.04658951e+01 0.82887371 0.88068292 427.25 7.21854126e+00 6.71617007e+00 9.85973013e+00 0.74936199 0.92692300 427.50 6.58404416e+00 5.51893751e+00 8.59117621e+00 0.69762064 0.90915221 427.75 6.30699015e+00 4.67858897e+00 7.85285423e+00 0.63823893 0.91376572 428.00 5.04564234e+00 2.97750040e+00 5.85867009e+00 0.53311811 0.83118940 428.25 4.07450226e+00 1.93322547e+00 4.50987022e+00 0.44301509 0.87830795 428.50 3.08010244e+00 1.09681000e+00 3.26956010e+00 0.34209458 0.76431256 428.75 2.19021804e+00 5.10947729e-01 2.24902704e+00 0.22918727 0.68606645 429.00 8.37733373e-02 5.15910600e-01 5.22667886e-01 1.40982176 0.07386848 429.25 -1.27642702e+00 4.60676339e-01 1.35701460e+00 2.79523097 0.46893147 429.50 -2.56534333e+00 1.11485105e+00 2.79711982e+00 2.73163437 0.70000880 429.75 -3.40582783e+00 2.43486939e+00 4.18667555e+00 2.52092816 0.85759893 430.00 -3.49642875e+00 3.72575426e+00 5.10942842e+00 2.32445222 0.87022525 430.25 -2.89334702e+00 4.63306327e+00 5.46230100e+00 2.12903586 0.88539850 430.50 -1.90542002e+00 5.24708159e+00 5.58233739e+00 1.91912799 0.93441483 430.75 -1.57556830e+00 5.08079016e+00 5.31947780e+00 1.87149597 0.93933939 431.00 -1.96496470e+00 4.83630038e+00 5.22023827e+00 1.95671763 0.92492311 431.25 -2.36754622e+00 4.73550631e+00 5.29436447e+00 2.03440898 0.91380110 431.50 -3.51270924e+00 6.28326956e+00 7.19851392e+00 2.08056690 0.91639375 431.75 -3.84357046e+00 6.79623759e+00 7.80780886e+00 2.08549503 0.92612757 432.00 -2.51478012e+00 9.30897515e+00 9.64267273e+00 1.83464401 0.88852085 432.25 -1.00660897e+00 9.65932290e+00 9.71163120e+00 1.67463266 0.85776255 432.50 2.85965640e+00 8.78748941e+00 9.24108245e+00 1.25618135 0.83612559 432.75 4.21942446e+00 7.85342404e+00 8.91514509e+00 1.07777762 0.83076197 433.00 4.41430301e+00 4.43259346e+00 6.25571385e+00 0.78746560 0.86169669 433.25 3.87790319e+00 3.87276322e+00 5.48054998e+00 0.78473500 0.88318110 433.50 3.16952667e+00 3.00336016e+00 4.36647130e+00 0.75848590 0.87049153 433.75 2.82262186e+00 2.75633463e+00 3.94519642e+00 0.77351707 0.87001268 434.00 1.66145194e+00 2.68253581e+00 3.15537968e+00 1.01626395 0.82563657 434.25 1.20317495e+00 2.50591563e+00 2.77979192e+00 1.12316756 0.79728287 434.50 5.94329159e-01 2.58819157e+00 2.65555319e+00 1.34507838 0.73010455 434.75 1.08318678e-01 2.79061795e+00 2.79271937e+00 1.53200050 0.70646034 435.00 -1.36873084e-01 3.35943890e+00 3.36222604e+00 1.61151665 0.73931933 435.25 2.69829391e-02 3.87514733e+00 3.87524127e+00 1.56383336 0.73416106 435.50 -1.20108348e-01 4.59028444e+00 4.59185553e+00 1.59695613 0.68078801 435.75 5.25297023e-01 5.79525749e+00 5.81901592e+00 1.48040078 0.53460649 436.00 1.66301940e+00 2.50362892e+00 3.00562661e+00 0.98447313 0.11735668 436.25 3.31390195e-02 -1.94829882e+00 1.94858063e+00 -1.55378876 0.07403034 436.50 -9.77176898e-01 -3.39307138e+00 3.53097835e+00 -1.85120039 0.48469489 436.75 -1.42618470e+00 -2.20359964e+00 2.62485317e+00 -2.14520547 0.43020255 437.00 -1.94054447e+00 -1.81365939e+00 2.65613878e+00 -2.38997976 0.63750237 437.25 -2.38682523e+00 -1.69917337e+00 2.92986772e+00 -2.52292677 0.67536997 437.50 -3.23179026e+00 -1.83841646e+00 3.71809674e+00 -2.62438961 0.82829365 437.75 -3.51118908e+00 -1.38777952e+00 3.77549742e+00 -2.76519222 0.79566459 438.00 -3.75574847e+00 -8.83842470e-01 3.85834474e+00 -2.91046744 0.79918589 438.25 -4.14893196e+00 -8.54314449e-01 4.23597563e+00 -2.93851909 0.80370368 438.50 -4.43904874e+00 -8.74809105e-01 4.52442755e+00 -2.94701473 0.86429937 438.75 -4.61695167e+00 -6.14493981e-01 4.65766524e+00 -3.00927513 0.80632514 439.00 -5.09475540e+00 -4.59320474e-01 5.11541864e+00 -3.05168018 0.80910194 439.25 -5.26287761e+00 -7.32524737e-01 5.31361207e+00 -3.00329406 0.72450592 439.50 -6.03762480e+00 -1.73038337e+00 6.28069581e+00 -2.86247430 0.76790607 439.75 -6.77735321e+00 -3.45160337e+00 7.60566120e+00 -2.67054478 0.74550715 440.00 -7.19964965e+00 -4.77905375e+00 8.64142985e+00 -2.55558440 0.72020112 440.25 -5.89476968e+00 -5.45716885e+00 8.03299455e+00 -2.39472397 0.50879906 440.50 -2.71933108e+00 -6.77947064e+00 7.30451804e+00 -1.95226147 0.39895034 440.75 3.77221347e+00 -5.67841768e+00 6.81718577e+00 -0.98442901 0.42454618 441.00 6.60990949e+00 -3.42781336e+00 7.44585844e+00 -0.47840643 0.58603548 441.25 5.99289296e+00 -2.90438457e-01 5.99992672e+00 -0.04842593 0.74035450 441.50 5.24219329e+00 9.95518742e-01 5.33588306e+00 0.18767026 0.78464425 441.75 4.30845726e+00 2.10142266e+00 4.79361880e+00 0.45379454 0.75365488 442.00 3.91950226e+00 2.30626070e+00 4.54767374e+00 0.53185127 0.71045425 442.25 3.05621746e+00 3.14607354e+00 4.38614225e+00 0.79988471 0.72932744 442.50 2.85413146e+00 3.62252170e+00 4.61180332e+00 0.90348620 0.78535041 442.75 3.34208518e+00 2.21332200e+00 4.00853186e+00 0.58494410 0.66443901 443.00 3.00713159e+00 1.71165658e+00 3.46014575e+00 0.51746382 0.70903693 443.25 1.79422475e+00 2.20163434e+00 2.84014722e+00 0.88700500 0.78238327 443.50 1.19554776e+00 2.47778995e+00 2.75114112e+00 1.12124186 0.79023381 443.75 8.25270906e-01 3.56921803e+00 3.66338497e+00 1.34357052 0.79506717 444.00 8.47349994e-01 4.04534440e+00 4.13313602e+00 1.36431850 0.81634351 444.25 1.79334853e+00 4.46275890e+00 4.80960663e+00 1.18869829 0.84802112 444.50 2.55911189e+00 4.21886488e+00 4.93435655e+00 1.02554695 0.83219800 444.75 3.30703760e+00 2.55914990e+00 4.18159610e+00 0.65859098 0.84800465 445.00 2.56274762e+00 2.35968627e+00 3.48364674e+00 0.74416931 0.83130336 445.25 1.67823993e+00 2.31804649e+00 2.86178769e+00 0.94415120 0.84746471 445.50 1.26656931e+00 2.43355000e+00 2.74342184e+00 1.09091376 0.79413661 445.75 7.18703392e-01 2.48601046e+00 2.58781424e+00 1.28937011 0.78910402 446.00 4.66842131e-01 2.82083290e+00 2.85920265e+00 1.40678497 0.78437515 446.25 7.12093110e-02 3.46627448e+00 3.46700585e+00 1.55025574 0.88083380 446.50 2.74041819e-01 3.88877641e+00 3.89842031e+00 1.50044270 0.88702045 446.75 9.27374557e-01 4.64392913e+00 4.73562048e+00 1.37369299 0.92294568 447.00 1.24309838e+00 5.07557001e+00 5.22558174e+00 1.33060643 0.91530510 447.25 2.05971497e+00 5.46446920e+00 5.83976450e+00 1.21033586 0.91869125 447.50 3.09639800e+00 5.35631339e+00 6.18690340e+00 1.04664758 0.92533613 447.75 4.24119712e+00 5.04264136e+00 6.58908073e+00 0.87151149 0.95317389 448.00 5.05967087e+00 4.35553524e+00 6.67614833e+00 0.71075006 0.92772009 448.25 5.72797247e+00 2.89304694e+00 6.41711689e+00 0.46769814 0.91332164 448.50 5.52621682e+00 7.67580274e-01 5.57926983e+00 0.13801493 0.86105690 448.75 4.97810808e+00 -2.32775791e-01 4.98354740e+00 -0.04672586 0.91216012 449.00 4.15777315e+00 -7.06256339e-01 4.21733039e+00 -0.16825806 0.88190465 449.25 3.55262561e+00 -9.56751709e-01 3.67920135e+00 -0.26306706 0.88765521 449.50 3.00573125e+00 -9.88024207e-01 3.16395515e+00 -0.31758689 0.85935126 449.75 2.46846165e+00 -8.43478638e-01 2.60859333e+00 -0.32926348 0.79516934 450.00 2.11752120e+00 -1.10841064e+00 2.39007745e+00 -0.48222897 0.80110745 450.25 1.87982743e+00 -1.12575516e+00 2.19113574e+00 -0.53958151 0.87261811 450.50 1.56572803e+00 -1.11053516e+00 1.91958136e+00 -0.61692516 0.83808891 450.75 1.32608824e+00 -1.13235813e+00 1.74377319e+00 -0.70675883 0.80337308 451.00 1.13146109e+00 -8.57327340e-01 1.41958246e+00 -0.64842175 0.77106316 451.25 1.00187503e+00 -9.22229134e-01 1.36171221e+00 -0.74402803 0.78843314 451.50 1.09753959e+00 -1.07382209e+00 1.53547616e+00 -0.77447573 0.82857317 451.75 1.07081226e+00 -1.17518971e+00 1.58987728e+00 -0.83183730 0.84730196 452.00 8.02611561e-01 -1.48193428e+00 1.68532327e+00 -1.07442723 0.76151757 452.25 3.96898411e-01 -1.68711782e+00 1.73317480e+00 -1.33974525 0.68244730 452.50 -2.58887615e-01 -1.71021489e+00 1.72969875e+00 -1.72103294 0.76083050 452.75 -5.17249323e-01 -1.80605944e+00 1.87866910e+00 -1.84972671 0.79272926 453.00 -5.65309410e-01 -1.66002131e+00 1.75363778e+00 -1.89902190 0.63668181 453.25 -6.59547528e-01 -1.70051612e+00 1.82394025e+00 -1.94078609 0.59929103 453.50 -1.05884165e+00 -2.37272112e+00 2.59825925e+00 -1.99053260 0.61769578 453.75 -1.27920675e+00 -2.67344583e+00 2.96372781e+00 -2.01708519 0.64218568 454.00 -2.08215232e+00 -3.49430983e+00 4.06762332e+00 -2.10817309 0.70646465 454.25 -3.03258110e+00 -3.90609175e+00 4.94510879e+00 -2.23096312 0.68246205 454.50 -5.87390746e+00 -3.26238492e+00 6.71907317e+00 -2.63461085 0.50997959 454.75 -7.40581863e+00 5.13366169e-01 7.42359040e+00 3.07238406 0.55779983 455.00 -7.72211116e+00 2.86875041e+00 8.23776242e+00 2.78589558 0.83162543 455.25 -7.01392290e+00 3.78456162e+00 7.96981939e+00 2.64678583 0.83021957 455.50 -5.09054791e+00 3.99705357e+00 6.47225735e+00 2.47594690 0.79979721 455.75 -4.38274984e+00 3.81842681e+00 5.81282026e+00 2.42489620 0.73892256 456.00 -3.45375988e+00 3.36955887e+00 4.82518231e+00 2.36853405 0.78760581 456.25 -3.82814171e+00 3.08967893e+00 4.91942933e+00 2.46253967 0.82244732 456.50 -4.06168955e+00 2.98629628e+00 5.04135770e+00 2.50760831 0.86652344 456.75 -4.34570498e+00 3.18551709e+00 5.38819737e+00 2.50904335 0.84470789 457.00 -5.03559016e+00 3.63614360e+00 6.21117609e+00 2.51619526 0.87362180 457.25 -5.11065639e+00 4.25429193e+00 6.64964725e+00 2.44738447 0.86784303 457.50 -4.70527459e+00 4.82760113e+00 6.74131602e+00 2.34336312 0.91016595 457.75 -4.38316567e+00 5.22600818e+00 6.82079928e+00 2.26870612 0.89666602 458.00 -4.07432955e+00 6.16145152e+00 7.38672093e+00 2.15504742 0.92181355 458.25 -3.40762115e+00 6.94965394e+00 7.74012738e+00 2.02667774 0.93470058 458.50 -2.90416248e+00 7.10607460e+00 7.67661748e+00 1.95876925 0.96464665 458.75 -2.44570508e+00 7.13702221e+00 7.54443897e+00 1.90093395 0.94655032 459.00 -1.86073891e+00 7.14754405e+00 7.38577926e+00 1.82547592 0.94218041 459.25 -1.78263695e+00 7.26324726e+00 7.47880707e+00 1.81147157 0.95237511 459.50 -1.74922425e+00 7.50285736e+00 7.70406737e+00 1.79984592 0.97222869 459.75 -1.34700379e+00 7.47425368e+00 7.59466177e+00 1.74910155 0.96008375 460.00 -8.69482360e-01 7.44536439e+00 7.49596228e+00 1.68705145 0.95483490 460.25 -4.72000168e-01 7.80482704e+00 7.81908622e+00 1.63119818 0.96063418 460.50 -2.06435761e-01 8.15695779e+00 8.15956960e+00 1.59609886 0.96762801 460.75 7.13055126e-01 8.32266415e+00 8.35315427e+00 1.48532874 0.92948839 461.00 1.21177098e+00 8.46304477e+00 8.54935762e+00 1.42857915 0.94738056 461.25 1.79740149e+00 8.07930527e+00 8.27682461e+00 1.35189146 0.91663209 461.50 2.36037213e+00 7.92643998e+00 8.27041760e+00 1.28137320 0.92087877 461.75 3.92998718e+00 7.90951847e+00 8.83205988e+00 1.10965740 0.89544188 462.00 5.06557176e+00 7.36979705e+00 8.94281420e+00 0.96861621 0.89005288 462.25 6.16065620e+00 5.19561138e+00 8.05903607e+00 0.70062279 0.89344696 462.50 6.19488640e+00 4.53251032e+00 7.67595384e+00 0.63165558 0.92130297 462.75 5.39330760e+00 3.71084336e+00 6.54661174e+00 0.60265796 0.94710032 463.00 5.18461428e+00 3.45686275e+00 6.23138230e+00 0.58806312 0.94338675 463.25 4.69821743e+00 2.82922271e+00 5.48431839e+00 0.54202873 0.92550005 463.50 4.66643332e+00 2.63216831e+00 5.35760300e+00 0.51357695 0.93457875 463.75 4.15683909e+00 2.12906590e+00 4.67035683e+00 0.47334712 0.92694682 464.00 4.22694404e+00 2.07360514e+00 4.70817313e+00 0.45607389 0.92220658 464.25 4.41425693e+00 1.82038539e+00 4.77487876e+00 0.39113963 0.92076142 464.50 4.43983275e+00 1.37073900e+00 4.64661600e+00 0.29945265 0.92019094 464.75 4.62613126e+00 8.78039248e-01 4.70871993e+00 0.18756881 0.92309794 465.00 4.40510457e+00 4.31814296e-01 4.42621846e+00 0.09771371 0.88454979 465.25 3.67008993e+00 -2.70450729e-01 3.68004126e+00 -0.07355754 0.92284143 465.50 3.21720403e+00 -3.16476226e-01 3.23273243e+00 -0.09805449 0.91199138 465.75 2.70343553e+00 -3.22250821e-02 2.70362758e+00 -0.01191948 0.93828809 466.00 2.54484987e+00 -8.67658025e-02 2.54632857e+00 -0.03408146 0.94375528 466.25 2.43552045e+00 -1.61918068e-01 2.44089683e+00 -0.06638423 0.95476409 466.50 2.27754331e+00 -1.68405057e-01 2.28376089e+00 -0.07380722 0.94992364 466.75 2.16130176e+00 -9.52309430e-02 2.16339876e+00 -0.04403336 0.95684026 467.00 2.08516857e+00 -1.05038949e-01 2.08781253e+00 -0.05033178 0.95874453 467.25 2.08707919e+00 -1.78397463e-01 2.09468976e+00 -0.08526983 0.97671592 467.50 1.97138752e+00 -2.80156866e-01 1.99119477e+00 -0.14116626 0.96895401 467.75 1.80963935e+00 -3.44871883e-01 1.84220823e+00 -0.18831678 0.97505401 468.00 1.79082872e+00 -3.78023676e-01 1.83029217e+00 -0.20803467 0.97261749 468.25 1.74104448e+00 -4.27685966e-01 1.79280539e+00 -0.24087950 0.97327013 468.50 1.68194870e+00 -5.08128470e-01 1.75702759e+00 -0.29338870 0.97000781 468.75 1.66027502e+00 -6.16405507e-01 1.77100788e+00 -0.35549399 0.97553786 469.00 1.61114067e+00 -7.06454966e-01 1.75921939e+00 -0.41323375 0.96184025 469.25 1.52296930e+00 -7.40263900e-01 1.69334761e+00 -0.45243856 0.95873244 469.50 1.48899214e+00 -8.72153183e-01 1.72561548e+00 -0.52986368 0.95047901 469.75 1.42654514e+00 -1.00278835e+00 1.74373607e+00 -0.61270236 0.95805101 470.00 1.32974809e+00 -1.19582024e+00 1.78835567e+00 -0.73241899 0.94496676 470.25 1.25962334e+00 -1.31919061e+00 1.82398323e+00 -0.80849277 0.95634321 470.50 1.11300933e+00 -1.64232655e+00 1.98394210e+00 -0.97519218 0.93488902 470.75 1.06325505e+00 -1.88238080e+00 2.16191322e+00 -1.05662662 0.95754301 471.00 7.99543117e-01 -2.06271943e+00 2.21225691e+00 -1.20101116 0.92571308 471.25 4.91418964e-01 -2.28208361e+00 2.33439461e+00 -1.35869727 0.92656275 471.50 1.10080559e-02 -2.61040539e+00 2.61042860e+00 -1.56657936 0.93528077 471.75 -3.24075539e-01 -2.70016392e+00 2.71954227e+00 -1.69024565 0.95479382 472.00 -7.81441371e-01 -2.80695950e+00 2.91370421e+00 -1.84231539 0.94932913 472.25 -1.11162388e+00 -2.78070303e+00 2.99466476e+00 -1.95109890 0.95011841 472.50 -1.81574729e+00 -2.78463463e+00 3.32432373e+00 -2.14861794 0.95776467 472.75 -2.21912893e+00 -2.81530207e+00 3.58475368e+00 -2.23832424 0.96737428 473.00 -2.91812019e+00 -2.59814338e+00 3.90714403e+00 -2.41413564 0.95730681 473.25 -3.32894045e+00 -2.30456798e+00 4.04881194e+00 -2.53606486 0.94971998 473.50 -3.86376887e+00 -1.73421818e+00 4.23511777e+00 -2.71970291 0.95119135 473.75 -4.10040036e+00 -1.52640644e+00 4.37529424e+00 -2.78522818 0.95873441 474.00 -4.72735475e+00 -7.78260527e-01 4.79098867e+00 -2.97842705 0.94898304 474.25 -4.74572917e+00 -2.90032911e-01 4.75458352e+00 -3.08055406 0.96304436 474.50 -4.60649600e+00 3.06538911e-01 4.61668404e+00 3.07514570 0.95899212 474.75 -4.51544302e+00 6.81189328e-01 4.56653529e+00 2.99186399 0.95366090 475.00 -4.24544656e+00 1.03820847e+00 4.37054840e+00 2.90175339 0.94278788 475.25 -3.94610193e+00 1.23308615e+00 4.13427405e+00 2.83872411 0.93468500 475.50 -3.66089222e+00 1.77510044e+00 4.06855176e+00 2.69011249 0.91908388 475.75 -3.66279023e+00 1.98878626e+00 4.16788952e+00 2.64416255 0.90865156 476.00 -3.79802607e+00 2.70608309e+00 4.66346306e+00 2.52252843 0.92636091 476.25 -3.63849742e+00 3.03670631e+00 4.73922448e+00 2.44610465 0.89479183 476.50 -3.01305159e+00 3.52916339e+00 4.64041745e+00 2.27746808 0.81445498 476.75 -2.57457369e+00 3.26900292e+00 4.16110680e+00 2.23791287 0.80756119 477.00 -1.63423565e+00 2.92280326e+00 3.34865721e+00 2.08062436 0.76288584 477.25 -1.39126452e+00 2.37593484e+00 2.75330407e+00 2.10053431 0.69357193 477.50 -1.66188019e+00 1.93077457e+00 2.54749607e+00 2.28148818 0.77751548 477.75 -1.82450977e+00 1.64187947e+00 2.45450689e+00 2.40883186 0.81045624 478.00 -1.99663204e+00 1.44928330e+00 2.46717684e+00 2.51371837 0.87682468 478.25 -2.25282484e+00 1.29989945e+00 2.60095335e+00 2.61825012 0.86982425 478.50 -2.59293976e+00 1.39094219e+00 2.94245761e+00 2.64922408 0.91579060 478.75 -2.94362905e+00 1.65387064e+00 3.37642416e+00 2.62969899 0.93493663 479.00 -3.28377953e+00 1.93542306e+00 3.81170178e+00 2.60901200 0.94599086 479.25 -3.48616078e+00 2.49920059e+00 4.28944293e+00 2.51961954 0.94702597 479.50 -3.54521300e+00 2.93769990e+00 4.60419547e+00 2.44963152 0.96173757 479.75 -3.34945943e+00 3.31816540e+00 4.71477465e+00 2.36088789 0.96981338 480.00 -3.21730647e+00 3.48651300e+00 4.74413679e+00 2.31605887 0.97801951 480.25 -3.17397867e+00 3.79747375e+00 4.94923706e+00 2.26699635 0.97758709 480.50 -3.17373447e+00 3.97733633e+00 5.08839806e+00 2.24428893 0.97660794 480.75 -3.06849447e+00 4.21520227e+00 5.21378830e+00 2.20004133 0.96290665 481.00 -2.98847967e+00 4.47986380e+00 5.38518249e+00 2.15909308 0.95542929 481.25 -2.65040194e+00 5.24042543e+00 5.87253686e+00 2.03904198 0.92981694 481.50 -2.42780937e+00 5.82533349e+00 6.31100377e+00 1.96567332 0.91767178 481.75 -9.53960587e-01 5.70267492e+00 5.78191509e+00 1.73654462 0.86883147 482.00 -3.08781430e-01 5.19537370e+00 5.20454166e+00 1.63016041 0.87100312 482.25 -5.38744196e-01 4.00866370e+00 4.04470394e+00 1.70439080 0.86246259 482.50 -8.34355560e-01 3.55630506e+00 3.65286940e+00 1.80124155 0.82612877 482.75 -2.49059666e+00 3.27391082e+00 4.11358284e+00 2.22113601 0.77094140 483.00 -3.80245398e+00 3.52826315e+00 5.18722441e+00 2.39358007 0.83882100 483.25 -4.43942514e+00 5.60229824e+00 7.14802358e+00 2.24090390 0.71156719 483.50 -3.45231914e+00 8.54949835e+00 9.22021852e+00 1.95457746 0.73802772 483.75 -2.66797307e+00 9.77479464e+00 1.01323586e+01 1.83725023 0.70595227 484.00 -1.24840797e+00 9.57428960e+00 9.65533759e+00 1.70045651 0.53831932 484.25 6.69647261e+00 4.89316380e+00 8.29372036e+00 0.63103925 0.29355593 484.50 8.19486680e+00 1.71268005e+00 8.37192420e+00 0.20602873 0.33550136 484.75 5.35191065e+00 6.98709695e-02 5.35236673e+00 0.01305459 0.45026583 485.00 3.93986137e+00 3.91210484e-01 3.95923645e+00 0.09897107 0.45172285 485.25 3.54273172e+00 2.02946735e+00 4.08285265e+00 0.52021986 0.61920663 485.50 3.93308417e+00 2.51843051e+00 4.67029371e+00 0.56953982 0.70130073 485.75 6.00733173e+00 3.06515817e+00 6.74412553e+00 0.47180300 0.73602162 486.00 6.64562608e+00 1.97836566e+00 6.93385007e+00 0.28934022 0.68193950 486.25 6.29006737e+00 -1.39306124e+00 6.44248144e+00 -0.21795201 0.64824594 486.50 5.33330060e+00 -2.37242660e+00 5.83716568e+00 -0.41854851 0.67549222 486.75 4.21402743e+00 -2.70706363e+00 5.00861465e+00 -0.57100931 0.81559135 487.00 3.70489421e+00 -2.71190790e+00 4.59137077e+00 -0.63186811 0.84507948 487.25 2.99925556e+00 -2.26985767e+00 3.76135451e+00 -0.64784339 0.84850655 487.50 2.67157826e+00 -2.33610321e+00 3.54890245e+00 -0.71850602 0.81520395 487.75 2.33824083e+00 -2.31629932e+00 3.29129347e+00 -0.78068420 0.85160224 488.00 2.29755799e+00 -2.30817061e+00 3.25675057e+00 -0.78770238 0.84015968 488.25 2.26799376e+00 -2.19426809e+00 3.15572624e+00 -0.76887763 0.83646962 488.50 1.86612046e+00 -2.24363085e+00 2.91826746e+00 -0.87699834 0.77822527 488.75 1.74768995e+00 -2.23070725e+00 2.83380928e+00 -0.90621687 0.80206278 489.00 1.85438249e+00 -2.27349296e+00 2.93385491e+00 -0.88658318 0.79883380 489.25 2.10986018e+00 -2.61640902e+00 3.36111680e+00 -0.89216790 0.87328925 489.50 1.97831623e+00 -3.32432219e+00 3.86844325e+00 -1.03398487 0.82003319 489.75 1.74725140e+00 -4.03235360e+00 4.39462888e+00 -1.16190976 0.83641518 490.00 6.16312573e-01 -4.16118961e+00 4.20658296e+00 -1.42375559 0.82387332 490.25 1.50425516e-01 -4.73026886e+00 4.73266006e+00 -1.53900641 0.89858225 490.50 -6.25939913e-01 -4.96156006e+00 5.00088783e+00 -1.69629123 0.88081961 490.75 -1.42758524e+00 -5.16577483e+00 5.35940568e+00 -1.84042139 0.91220973 491.00 -2.50704050e+00 -4.48180624e+00 5.13535191e+00 -2.08081385 0.87650250 491.25 -3.57108580e+00 -4.02259801e+00 5.37902859e+00 -2.29680549 0.92200475 491.50 -4.21970178e+00 -3.21532202e+00 5.30510874e+00 -2.49046928 0.93274846 491.75 -4.56316686e+00 -2.68719874e+00 5.29561412e+00 -2.60938307 0.95471425 492.00 -4.57087850e+00 -1.73983310e+00 4.89080254e+00 -2.77789150 0.95980619 492.25 -4.49676486e+00 -1.24338624e+00 4.66550143e+00 -2.87182609 0.96717705 492.50 -4.49296503e+00 -6.52336542e-01 4.54007464e+00 -2.99740951 0.95470503 492.75 -4.35820569e+00 -3.60410890e-01 4.37308276e+00 -3.05908332 0.97323162 493.00 -4.37615324e+00 5.70839454e-02 4.37652554e+00 3.12854907 0.97033108 493.25 -4.34264597e+00 3.14706147e-01 4.35403422e+00 3.06925036 0.97193356 493.50 -4.22277967e+00 6.86603117e-01 4.27823468e+00 2.98040814 0.97122853 493.75 -4.13470792e+00 9.28879838e-01 4.23776207e+00 2.92060730 0.97388274 494.00 -3.96520763e+00 1.15904452e+00 4.13113251e+00 2.85721163 0.96944058 494.25 -3.82281741e+00 1.38987768e+00 4.06763972e+00 2.79287658 0.97220851 494.50 -3.64057206e+00 1.63954007e+00 3.99272545e+00 2.71844578 0.97216047 494.75 -3.50494633e+00 1.87253010e+00 3.97379135e+00 2.65091915 0.96717098 495.00 -3.40887403e+00 2.30719908e+00 4.11625920e+00 2.54659272 0.97286713 495.25 -3.22855058e+00 2.40074388e+00 4.02332077e+00 2.50220141 0.97077136 495.50 -2.76545076e+00 2.54213669e+00 3.75635153e+00 2.39824419 0.96277812 495.75 -2.55172532e+00 2.63984808e+00 3.67152557e+00 2.33922193 0.95953337 496.00 -2.12924543e+00 2.67680377e+00 3.42037491e+00 2.24275257 0.95705147 496.25 -1.92769195e+00 2.62051474e+00 3.25316673e+00 2.20502779 0.95858854 496.50 -1.49467821e+00 2.59925218e+00 2.99836203e+00 2.09266189 0.95606358 496.75 -1.26787845e+00 2.29979742e+00 2.62613479e+00 2.07463712 0.93186116 497.00 -1.03081236e+00 1.97870911e+00 2.23111270e+00 2.05106465 0.92188714 497.25 -1.01972096e+00 1.83923733e+00 2.10300375e+00 2.07703125 0.89086460 497.50 -1.11049513e+00 1.59849313e+00 1.94637605e+00 2.17796565 0.87789266 497.75 -1.09710454e+00 1.40719443e+00 1.78433028e+00 2.23299852 0.84605522 498.00 -1.14235447e+00 1.08179820e+00 1.57329625e+00 2.38341443 0.84885516 498.25 -1.16525591e+00 9.33233149e-01 1.49289834e+00 2.46631379 0.84121529 498.50 -1.34643717e+00 8.29767165e-01 1.58158357e+00 2.58929663 0.88791096 498.75 -1.51654998e+00 9.03187607e-01 1.76512653e+00 2.60444859 0.85795422 499.00 -1.57655827e+00 9.65444251e-01 1.84868023e+00 2.59212383 0.90984425 499.25 -1.39387619e+00 1.09502836e+00 1.77256253e+00 2.47569443 0.87773358 499.50 -1.29063042e+00 1.00160207e+00 1.63368711e+00 2.48162289 0.84592204 499.75 -1.33246747e+00 8.60422829e-01 1.58612642e+00 2.56822049 0.82377086 500.00 -1.37285762e+00 7.06119865e-01 1.54380806e+00 2.66653650 0.82966714 500.25 -1.29316489e+00 3.63172556e-01 1.34319386e+00 2.86780510 0.77961128 500.50 -1.36927845e+00 6.56683837e-02 1.37085222e+00 3.09367099 0.81627063 500.75 -1.40527223e+00 -5.86216433e-02 1.40649441e+00 -3.09990132 0.81560870 501.00 -1.40599483e+00 -3.38685179e-02 1.40640269e+00 -3.11750866 0.80336472 501.25 -1.57737519e+00 -3.57979886e-01 1.61748635e+00 -2.91842621 0.76761193 501.50 -1.65938847e+00 -6.23318518e-01 1.77259586e+00 -2.78226849 0.84057204 501.75 -1.97606226e+00 -8.04685492e-01 2.13362152e+00 -2.75488053 0.82788961 502.00 -2.20354907e+00 -9.44172015e-01 2.39730876e+00 -2.73677991 0.88031999 502.25 -2.32179232e+00 -1.44899905e+00 2.73684450e+00 -2.58365056 0.90495682 502.50 -2.43277287e+00 -1.78226853e+00 3.01576938e+00 -2.50931575 0.93051608 502.75 -2.88163644e+00 -2.27531828e+00 3.67163477e+00 -2.47323010 0.92401248 503.00 -3.27916621e+00 -2.74399522e+00 4.27579710e+00 -2.44481395 0.94455096 503.25 -3.97876790e+00 -2.89165400e+00 4.91856249e+00 -2.51312446 0.91524154 503.50 -4.47219631e+00 -2.93494313e+00 5.34924584e+00 -2.56082625 0.92410659 503.75 -5.53442842e+00 -2.99047332e+00 6.29069381e+00 -2.64619615 0.93626670 504.00 -6.28007051e+00 -3.02776936e+00 6.97184860e+00 -2.69234828 0.95462679 504.25 -6.43845419e+00 -2.82941095e+00 7.03272768e+00 -2.72754246 0.95330434 504.50 -6.49147178e+00 -2.87388686e+00 7.09918528e+00 -2.72481150 0.96080553 504.75 -6.79123240e+00 -3.00278643e+00 7.42546725e+00 -2.72528063 0.94070851 505.00 -7.14022793e+00 -3.26909178e+00 7.85301318e+00 -2.71223700 0.93720050 505.25 -8.21541014e+00 -3.48585345e+00 8.92435645e+00 -2.74030940 0.93321525 505.50 -8.94946751e+00 -3.77247696e+00 9.71208274e+00 -2.74266404 0.91172066 505.75 -1.00876813e+01 -4.76275920e+00 1.11555004e+01 -2.70048354 0.88775289 506.00 -1.04681285e+01 -4.33249433e+00 1.13292639e+01 -2.74918278 0.86114132 506.25 -1.08464352e+01 -2.40183964e+00 1.11091850e+01 -2.92366880 0.81915537 506.50 -9.60059176e+00 -1.51324912e+00 9.71911956e+00 -2.98525845 0.74833070 506.75 -6.84258757e+00 -1.56383474e+00 7.01901587e+00 -2.91690722 0.70490734 507.00 -5.26334016e+00 -4.41853242e+00 6.87213056e+00 -2.44323069 0.68504986 507.25 -4.33620426e+00 -8.17941443e+00 9.25772585e+00 -2.05826129 0.77324325 507.50 -2.97663755e+00 -9.55820471e+00 1.00109764e+01 -1.87269902 0.70539436 507.75 -7.94909875e-01 -1.09513968e+01 1.09802083e+01 -1.64325450 0.68025530 508.00 8.76892779e-01 -1.14580935e+01 1.14915990e+01 -1.49441479 0.69305698 508.25 3.90062819e+00 -1.18299390e+01 1.24564183e+01 -1.25229666 0.73330690 508.50 3.93121439e+00 -1.12714003e+01 1.19372907e+01 -1.23521073 0.63896348 508.75 5.72536199e+00 -8.52600205e+00 1.02699796e+01 -0.97944277 0.61848915 509.00 6.91996469e+00 -6.23670133e+00 9.31570473e+00 -0.73351191 0.63779274 509.25 7.77113076e+00 -4.26559735e+00 8.86486289e+00 -0.50200063 0.66599472 509.50 8.45747325e+00 -2.72879178e+00 8.88679685e+00 -0.31210366 0.64679215 509.75 8.31935901e+00 -9.62981181e-01 8.37490699e+00 -0.11523900 0.62327461 510.00 6.06673180e+00 -1.35201716e-01 6.06823815e+00 -0.02228207 0.56309453 510.25 5.39102084e+00 1.28061150e+00 5.54103524e+00 0.23322265 0.62815631 510.50 4.37100110e+00 2.39455047e+00 4.98392642e+00 0.50117301 0.66796490 510.75 3.69228633e+00 2.61689816e+00 4.52560872e+00 0.61657258 0.73130484 511.00 2.26966509e+00 3.15920838e+00 3.88998422e+00 0.94780907 0.57063250 511.25 1.14550415e+00 2.95850508e+00 3.17252770e+00 1.20138143 0.35631621 511.50 2.32642732e-01 2.25285296e+00 2.26483313e+00 1.46789524 0.16865752 511.75 -2.55103818e-01 2.30520708e+00 2.31927955e+00 1.68101203 0.10108837 512.00 -2.19228613e+00 2.88220209e+00 3.62121628e+00 2.22106528 0.20242963 512.25 -2.16009736e+00 2.42261964e+00 3.24578288e+00 2.29897174 0.16654099 512.50 -2.43473182e+00 2.29616754e+00 3.34668559e+00 2.38547532 0.17241515 512.75 -3.38707244e+00 3.68155745e+00 5.00261181e+00 2.31455773 0.31226389 513.00 -1.95060595e+00 3.39620733e+00 3.91651475e+00 2.09214071 0.28060918 513.25 -2.40679553e+00 3.45933285e+00 4.21421980e+00 2.17865737 0.34621422 513.50 -2.88797379e+00 2.57906480e+00 3.87194626e+00 2.41263837 0.30930618 513.75 -2.66608372e+00 2.00233257e+00 3.33426726e+00 2.49742698 0.34502803 514.00 -3.90163056e+00 2.12753546e-01 3.90742691e+00 3.08711721 0.57320804 514.25 -3.61640755e+00 -5.83512889e-01 3.66318043e+00 -2.98161988 0.71029756 514.50 -2.70594984e+00 -1.12378640e+00 2.93002738e+00 -2.74796488 0.73806922 514.75 -2.52870108e+00 -1.23240611e+00 2.81303288e+00 -2.68810222 0.78383384 515.00 -1.94448340e+00 -1.39733566e+00 2.39448588e+00 -2.51848210 0.82087925 515.25 -1.64482540e+00 -1.60394333e+00 2.29740828e+00 -2.36877769 0.83883434 515.50 -1.20132623e+00 -1.90231806e+00 2.24988860e+00 -2.13406080 0.84547498 515.75 -9.48633920e-01 -2.02393994e+00 2.23522688e+00 -2.00909727 0.84170484 516.00 -4.78122004e-01 -2.58274896e+00 2.62663147e+00 -1.75384544 0.82518005 516.25 -4.75626292e-01 -2.83553960e+00 2.87515307e+00 -1.73698670 0.86316379 516.50 -4.50281795e-01 -2.98559439e+00 3.01935880e+00 -1.72048632 0.91763441 516.75 -4.54534887e-01 -2.98582652e+00 3.02022549e+00 -1.72186731 0.92062108 517.00 -5.98182573e-01 -2.91512940e+00 2.97586993e+00 -1.77318620 0.85289476 517.25 -6.37989638e-01 -2.82144305e+00 2.89267552e+00 -1.79317821 0.86737994 517.50 -5.21240676e-01 -2.48363544e+00 2.53774247e+00 -1.77766405 0.87877744 517.75 -4.23649288e-01 -2.37722320e+00 2.41467779e+00 -1.74715667 0.84326860 518.00 3.55769706e-02 -2.30022230e+00 2.30049742e+00 -1.55533081 0.77587953 518.25 3.26251687e-01 -2.46913782e+00 2.49059867e+00 -1.43942550 0.72939189 518.50 6.69354511e-01 -2.87153162e+00 2.94851307e+00 -1.34178553 0.76839224 518.75 4.44743600e-01 -3.00195104e+00 3.03471694e+00 -1.42371468 0.69112612 519.00 -3.73682098e-01 -3.43855712e+00 3.45880231e+00 -1.67904562 0.72558846 519.25 -9.20584567e-01 -3.24140958e+00 3.36960117e+00 -1.84751729 0.79278121 519.50 -1.31359086e+00 -3.03122497e+00 3.30361102e+00 -1.97972083 0.89391845 519.75 -1.36135282e+00 -2.82788639e+00 3.13850648e+00 -2.01945591 0.85885773 520.00 -1.52053568e+00 -2.70105867e+00 3.09963654e+00 -2.08352045 0.82766826 520.25 -2.21337466e+00 -2.76943927e+00 3.54525335e+00 -2.24505782 0.86247583 520.50 -2.59185033e+00 -2.46305510e+00 3.57551794e+00 -2.38166823 0.89516111 520.75 -2.84516824e+00 -1.64588755e+00 3.28693293e+00 -2.61714314 0.84448557 521.00 -3.21665807e+00 -7.97742002e-01 3.31410341e+00 -2.89849406 0.84150528 521.25 -3.00130267e+00 4.49767263e-01 3.03481603e+00 2.99284222 0.78920321 521.50 -2.08696577e+00 1.68564915e+00 2.68269253e+00 2.46217219 0.76001527 521.75 -5.79731587e-01 1.99344107e+00 2.07602891e+00 1.85380953 0.62220193 522.00 8.98291146e-01 1.81523627e+00 2.02534187e+00 1.11126769 0.59949657 522.25 1.65539187e+00 4.09148892e-01 1.70520528e+00 0.24230522 0.59966455 522.50 1.79608842e+00 -4.80824428e-01 1.85933475e+00 -0.26157288 0.76550327 522.75 1.59994071e+00 -1.12707154e+00 1.95706426e+00 -0.61370351 0.78096303 523.00 1.50791776e+00 -1.52976431e+00 2.14802114e+00 -0.79258989 0.84381293 523.25 1.12038113e+00 -2.25413991e+00 2.51722081e+00 -1.10952542 0.85707840 523.50 7.03377857e-01 -2.59721553e+00 2.69077478e+00 -1.30632039 0.92819764 523.75 -6.13514608e-02 -2.96744345e+00 2.96807759e+00 -1.59146824 0.91587537 524.00 -7.23241170e-01 -2.93389312e+00 3.02172246e+00 -1.81248990 0.92779186 524.25 -1.32487754e+00 -2.65835224e+00 2.97020826e+00 -2.03314949 0.93109651 524.50 -1.66555182e+00 -2.41719964e+00 2.93545856e+00 -2.17412994 0.93762323 524.75 -2.21000862e+00 -1.73385697e+00 2.80898524e+00 -2.47634518 0.91700358 525.00 -2.39395427e+00 -1.40023673e+00 2.77338781e+00 -2.61234608 0.92997992 525.25 -2.47538909e+00 -7.14057333e-01 2.57632083e+00 -2.86075389 0.93006549 525.50 -2.48119390e+00 -4.78668083e-01 2.52694406e+00 -2.95101546 0.93951454 525.75 -2.24129276e+00 2.34629582e-01 2.25354039e+00 3.03728764 0.87330239 526.00 -2.01753837e+00 5.61287956e-01 2.09415979e+00 2.87024983 0.87019859 526.25 -1.42009465e+00 1.12862662e+00 1.81396440e+00 2.47005838 0.85227230 526.50 -1.12965577e+00 1.17414622e+00 1.62933775e+00 2.33688514 0.87404314 526.75 -7.07672334e-01 1.09390649e+00 1.30285515e+00 2.14500481 0.86958265 527.00 -5.11110251e-01 1.01784017e+00 1.13896106e+00 2.03616388 0.85254667 527.25 -2.98203234e-01 8.19263746e-01 8.71847609e-01 1.91987901 0.84556092 527.50 -2.56109175e-01 7.21481236e-01 7.65589370e-01 1.91189801 0.85248790 527.75 -2.01037702e-01 6.14994501e-01 6.47019624e-01 1.88673987 0.90177443 528.00 -1.89707707e-01 5.69309054e-01 6.00084838e-01 1.89244890 0.89131136 528.25 -1.32618681e-01 4.99219788e-01 5.16534715e-01 1.83045107 0.89119315 528.50 -1.33315617e-01 4.80650986e-01 4.98796977e-01 1.84135965 0.88686116 528.75 -1.35165146e-01 4.25690231e-01 4.46633843e-01 1.87824798 0.90333620 529.00 -1.34108152e-01 4.09813889e-01 4.31198817e-01 1.88705434 0.89715377 529.25 -1.57721229e-01 3.87584313e-01 4.18446635e-01 1.95726595 0.92966407 529.50 -1.52958666e-01 3.97028076e-01 4.25473438e-01 1.93853077 0.91951315 529.75 -1.07698968e-01 3.92322695e-01 4.06836779e-01 1.83871277 0.93080040 530.00 -8.89097665e-02 3.83203471e-01 3.93382571e-01 1.79877965 0.90372911 530.25 -7.60407333e-02 3.54110666e-01 3.62183043e-01 1.78232129 0.88872559 530.50 -8.53334522e-02 3.35374856e-01 3.46060821e-01 1.81995132 0.88983939 530.75 -9.90300437e-02 3.12094707e-01 3.27429467e-01 1.87805512 0.90368865 531.00 -1.04473361e-01 3.17497687e-01 3.34244618e-01 1.88868906 0.88048445 531.25 -1.11549117e-01 3.40038368e-01 3.57867709e-01 1.88778312 0.88378564 531.50 -1.04057495e-01 3.15084784e-01 3.31822819e-01 1.88977145 0.83477410 531.75 -1.07380160e-01 2.74796624e-01 2.95031665e-01 1.94331389 0.84266796 532.00 -1.64224476e-01 2.19745448e-01 2.74331443e-01 2.21259261 0.81115446 532.25 -2.30535759e-01 1.95654779e-01 3.02369855e-01 2.43785611 0.84480340 532.50 -3.62041361e-01 1.95234085e-01 4.11327479e-01 2.64703323 0.84960843 532.75 -4.73717245e-01 2.40003768e-01 5.31045984e-01 2.67264773 0.91470542 533.00 -5.84194014e-01 3.89989236e-01 7.02406043e-01 2.55296630 0.90785826 533.25 -6.29999042e-01 5.14331167e-01 8.13286753e-01 2.45693145 0.94945099 533.50 -6.24006268e-01 6.80773834e-01 9.23491654e-01 2.31271453 0.93823805 533.75 -5.97188973e-01 7.82583342e-01 9.84414220e-01 2.22262855 0.94353998 534.00 -5.53130491e-01 8.97497768e-01 1.05425594e+00 2.12311710 0.94421842 534.25 -5.19254869e-01 9.67264215e-01 1.09782771e+00 2.06347075 0.95437178 534.50 -4.39203305e-01 1.18415632e+00 1.26298287e+00 1.92596744 0.95465805 534.75 -3.67091348e-01 1.28127545e+00 1.33282514e+00 1.84982653 0.96241635 535.00 -2.84251197e-01 1.43969240e+00 1.46748524e+00 1.76572802 0.95212247 535.25 -1.83568358e-01 1.51330719e+00 1.52440021e+00 1.69150933 0.95769449 535.50 3.23111550e-02 1.58617090e+00 1.58649996e+00 1.55042861 0.93350982 535.75 2.10226901e-01 1.63157792e+00 1.64506591e+00 1.44265353 0.93820801 536.00 5.63040112e-01 1.53850984e+00 1.63829994e+00 1.21997055 0.92142602 536.25 7.59102481e-01 1.44162843e+00 1.62927257e+00 1.08612793 0.91136955 536.50 9.65320010e-01 1.23142559e+00 1.56468901e+00 0.90594708 0.92285351 536.75 1.00517059e+00 1.12076657e+00 1.50548517e+00 0.83971880 0.92725263 537.00 1.15579451e+00 8.93305624e-01 1.46077236e+00 0.65799244 0.89626329 537.25 1.21749368e+00 7.07979855e-01 1.40837720e+00 0.52670995 0.82461302 537.50 1.04934902e+00 8.99088021e-02 1.05319370e+00 0.08547180 0.53634301 537.75 8.40817117e-01 -1.32212739e-01 8.51148420e-01 -0.15596608 0.38080892 538.00 2.18075997e-01 -4.65852701e-01 5.14369399e-01 -1.13297459 0.07610733 538.25 -3.88870518e-01 1.13943242e-03 3.88872188e-01 3.13866255 0.02541352 538.50 -2.07610432e-01 1.95206530e+00 1.96307438e+00 1.67675227 0.26943849 538.75 8.13905120e-01 2.00680160e+00 2.16557018e+00 1.18549465 0.41290853 539.00 1.82156450e+00 1.34895766e+00 2.26666804e+00 0.63742494 0.56022515 539.25 1.50740573e+00 9.17874587e-01 1.76486991e+00 0.54694531 0.55316205 539.50 1.42349240e+00 5.82244119e-01 1.53796581e+00 0.38826234 0.65237042 539.75 1.30019590e+00 3.73835765e-01 1.35287197e+00 0.27997074 0.53320919 540.00 1.24212631e+00 3.85642139e-01 1.30061433e+00 0.30103381 0.44439497 540.25 1.38626441e+00 4.02284591e-01 1.44345486e+00 0.28243568 0.41091337 540.50 1.27748582e+00 3.78644350e-01 1.33241944e+00 0.28814902 0.42062447 540.75 1.12219903e+00 3.36888422e-01 1.17167593e+00 0.29164376 0.47211166 541.00 1.06818135e+00 3.68810422e-01 1.13005864e+00 0.33245435 0.67262486 541.25 9.77545279e-01 3.65110392e-01 1.04350389e+00 0.35745247 0.58364877 541.50 7.82874095e-01 3.01197878e-01 8.38815838e-01 0.36727671 0.53154390 541.75 5.70146579e-01 2.63969108e-01 6.28288796e-01 0.43359933 0.34457919 542.00 4.92879968e-01 1.97284155e-01 5.30897071e-01 0.38073752 0.25769549 542.25 3.59412690e-01 3.36769413e-01 4.92535399e-01 0.75288469 0.24477642 542.50 2.42505681e-01 5.84350286e-01 6.32672318e-01 1.17742571 0.29711737 542.75 4.78046283e-01 8.46492918e-01 9.72151484e-01 1.05670880 0.29093467 543.00 1.17409277e+00 1.12180685e+00 1.62386712e+00 0.76262849 0.48665739 543.25 1.55906170e+00 5.92373744e-01 1.66780695e+00 0.36310794 0.58570218 543.50 1.49913951e+00 2.57271482e-01 1.52105486e+00 0.16995721 0.59310988 543.75 1.57900114e+00 -5.63922144e-02 1.58000781e+00 -0.03569868 0.80638475 544.00 1.61038774e+00 -1.34743881e-01 1.61601503e+00 -0.08347726 0.87954285 544.25 1.50520388e+00 -2.03625814e-01 1.51891480e+00 -0.13446490 0.79737186 544.50 1.39530475e+00 -3.56875690e-01 1.44022067e+00 -0.25040089 0.80632125 544.75 1.06472472e+00 -4.13290607e-01 1.14212428e+00 -0.37026376 0.80731088 545.00 1.06287389e+00 -4.75590085e-01 1.16442553e+00 -0.42073694 0.83696998 545.25 1.12646063e+00 -2.94953216e-01 1.16443590e+00 -0.25609141 0.84165300 545.50 1.12066310e+00 -1.88089512e-01 1.13633773e+00 -0.16628784 0.83399558 545.75 1.17270854e+00 -3.04345394e-01 1.21155744e+00 -0.25392165 0.82077750 546.00 1.26484972e+00 -3.83379323e-01 1.32167489e+00 -0.29430084 0.83803727 546.25 1.46666555e+00 -4.67430009e-01 1.53935007e+00 -0.30852554 0.87881974 546.50 1.51637028e+00 -5.96972082e-01 1.62964858e+00 -0.37505050 0.87373688 546.75 1.42018102e+00 -8.58311428e-01 1.65940129e+00 -0.54362480 0.83378412 547.00 1.34660347e+00 -8.86576747e-01 1.61225284e+00 -0.58224370 0.82461763 547.25 1.00467724e+00 -1.08482861e+00 1.47859037e+00 -0.82373838 0.81448237 547.50 9.11793591e-01 -1.11221796e+00 1.43819204e+00 -0.88409972 0.82849842 547.75 7.79425892e-01 -1.01384305e+00 1.27882073e+00 -0.91538171 0.67831949 548.00 1.03454816e+00 -9.01939539e-01 1.37251041e+00 -0.71702597 0.55638223 548.25 1.55395977e+00 -1.07554343e+00 1.88986365e+00 -0.60542508 0.69731703 548.50 1.59259483e+00 -1.30257146e+00 2.05743789e+00 -0.68555622 0.61883855 548.75 1.18499826e+00 -2.82919215e+00 3.06733583e+00 -1.17414896 0.54732098 549.00 -8.18094975e-03 -3.40997074e+00 3.40998055e+00 -1.57319545 0.58873773 549.25 -1.49389776e+00 -3.49422107e+00 3.80017255e+00 -1.97481120 0.65047497 549.50 -1.99789638e+00 -3.05764534e+00 3.65250393e+00 -2.14956508 0.64236785 549.75 -2.61833558e+00 -2.54157957e+00 3.64901465e+00 -2.37106883 0.74287726 550.00 -2.86378375e+00 -2.33812486e+00 3.69703736e+00 -2.45690379 0.67879837 550.25 -2.56701349e+00 -1.50012614e+00 2.97320310e+00 -2.61273333 0.67406028 550.50 -2.60480263e+00 -1.18966490e+00 2.86361648e+00 -2.71316462 0.71903856 550.75 -2.57540452e+00 -1.13459297e+00 2.81425117e+00 -2.72662557 0.74399609 551.00 -2.50482528e+00 -1.16070622e+00 2.76068626e+00 -2.70766113 0.79810824 551.25 -2.43771631e+00 -1.13482074e+00 2.68891780e+00 -2.70590244 0.81328361 551.50 -2.66603824e+00 -8.75732989e-01 2.80618392e+00 -2.82421890 0.80247028 551.75 -2.64127886e+00 -7.42163066e-01 2.74356703e+00 -2.86766963 0.77488620 552.00 -2.96399276e+00 -4.67975593e-01 3.00070895e+00 -2.98499843 0.75772692 552.25 -3.32898233e+00 -3.64955636e-01 3.34892759e+00 -3.03239892 0.82689014 552.50 -3.44773451e+00 -2.08679116e-01 3.45404404e+00 -3.08113996 0.86079319 552.75 -3.64961481e+00 2.93499886e-01 3.66139734e+00 3.06134593 0.89073265 553.00 -3.55255887e+00 8.29385258e-01 3.64808915e+00 2.91223930 0.86613499 553.25 -3.49140768e+00 1.20392309e+00 3.69315020e+00 2.80953590 0.84438988 553.50 -3.17847215e+00 1.62179561e+00 3.56831980e+00 2.66978365 0.83550742 553.75 -3.03593960e+00 1.78721654e+00 3.52293517e+00 2.60953347 0.82976079 554.00 -3.29359509e+00 1.92357018e+00 3.81416975e+00 2.61299589 0.84953330 554.25 -3.14298162e+00 1.99227504e+00 3.72122202e+00 2.57663277 0.87813096 554.50 -3.24600425e+00 2.16951968e+00 3.90427448e+00 2.55241434 0.84195346 554.75 -3.30314723e+00 2.38499968e+00 4.07418766e+00 2.51622833 0.86104175 555.00 -3.04937576e+00 2.60381259e+00 4.00980455e+00 2.43484815 0.87000253 555.25 -2.94436714e+00 2.52146131e+00 3.87647584e+00 2.43341333 0.88895100 555.50 -2.98659899e+00 2.74482616e+00 4.05633383e+00 2.39835322 0.90524345 555.75 -2.79455096e+00 3.05859729e+00 4.14301007e+00 2.31111321 0.91507313 556.00 -3.12337462e+00 3.40340292e+00 4.61937446e+00 2.31331626 0.89588485 556.25 -3.37525438e+00 3.77381346e+00 5.06300406e+00 2.30050234 0.90995665 556.50 -3.08654734e+00 4.65287103e+00 5.58354576e+00 2.15650901 0.86715557 556.75 -2.72637849e+00 5.34217896e+00 5.99766752e+00 2.04268923 0.87523983 557.00 -1.65496855e+00 6.24393078e+00 6.45953500e+00 1.82989097 0.86151950 557.25 -8.50743185e-01 6.50469769e+00 6.56009573e+00 1.70084718 0.86237322 557.50 1.09471161e+00 6.30204067e+00 6.39641384e+00 1.39880505 0.82030056 557.75 1.22176540e+00 6.00024619e+00 6.12337039e+00 1.36992319 0.82228460 558.00 1.57969644e+00 5.02341227e+00 5.26593883e+00 1.26612063 0.87164597 558.25 1.78887818e+00 4.66551024e+00 4.99670601e+00 1.20465897 0.83040196 558.50 1.38855713e+00 4.11724926e+00 4.34509290e+00 1.24552169 0.85471548 558.75 1.12791304e+00 3.78154021e+00 3.94616702e+00 1.28092913 0.85046793 559.00 1.11904447e+00 3.71399222e+00 3.87891721e+00 1.27814270 0.83887757 559.25 1.13767219e+00 3.80090040e+00 3.96751079e+00 1.27996672 0.81817479 559.50 1.49175952e+00 3.60794030e+00 3.90417464e+00 1.17873576 0.73816280 559.75 1.40866783e+00 3.44769348e+00 3.72437046e+00 1.18291306 0.68383445 560.00 1.80821578e+00 4.41225281e+00 4.76839797e+00 1.18185586 0.77734336 560.25 1.91352126e+00 4.33477860e+00 4.73834034e+00 1.15508818 0.74064391 560.50 1.51226612e+00 4.71175039e+00 4.94848871e+00 1.26022612 0.70180606 560.75 1.92355547e+00 5.02113560e+00 5.37697576e+00 1.20495049 0.67358348 561.00 2.84269787e+00 4.49619586e+00 5.31946505e+00 1.00700400 0.57997930 561.25 2.91540784e+00 4.60714746e+00 5.45210148e+00 1.00660691 0.56550807 561.50 4.08293588e+00 5.46943414e+00 6.82532602e+00 0.92953860 0.50900166 561.75 5.29737182e+00 3.25413032e+00 6.21703405e+00 0.55086171 0.43329028 562.00 6.26231721e+00 1.68113974e+00 6.48404562e+00 0.26226967 0.54544298 562.25 5.98034547e+00 -4.71341162e-01 5.99889110e+00 -0.07865245 0.56936701 562.50 6.60978609e+00 -1.35058759e+00 6.74635894e+00 -0.20155699 0.58355698 562.75 5.12055487e+00 -2.50784875e+00 5.70170041e+00 -0.45542301 0.60475881 563.00 4.42083164e+00 -2.79252657e+00 5.22895372e+00 -0.56338456 0.63971868 563.25 2.87970423e+00 -2.50056215e+00 3.81385730e+00 -0.71504545 0.64412918 563.50 2.33085153e+00 -2.38069016e+00 3.33174946e+00 -0.79597576 0.65116750 563.75 1.63257684e+00 -1.83954592e+00 2.45951953e+00 -0.84493652 0.55489187 564.00 1.22477419e+00 -1.80519773e+00 2.18146984e+00 -0.97466600 0.59357547 564.25 7.32421599e-01 -8.54512787e-01 1.12544813e+00 -0.86218215 0.31631097 564.50 8.86176967e-01 -4.95335874e-01 1.01521783e+00 -0.50969488 0.33795736 564.75 8.84764413e-01 3.85234912e-02 8.85602691e-01 0.04351348 0.26568165 565.00 8.37610799e-01 5.24018909e-01 9.88022098e-01 0.55903889 0.27471691 565.25 1.60238027e+00 6.78497111e-01 1.74010944e+00 0.40054074 0.46648720 565.50 1.85206568e+00 5.44142119e-01 1.93034659e+00 0.28576165 0.49400362 565.75 1.95758445e+00 -4.31840459e-01 2.00465036e+00 -0.21712123 0.41396718 566.00 1.86020492e+00 -6.09737213e-01 1.95758571e+00 -0.31674389 0.41188216 566.25 5.86287567e-01 -2.04116847e-01 6.20803349e-01 -0.33502703 0.06789141 566.50 -1.17002244e-01 1.32614755e-01 1.76850780e-01 2.29372999 0.00718080 566.75 -1.96831756e-01 1.27966487e+00 1.29471423e+00 1.72341530 0.30098987 567.00 1.89864880e-01 1.78075282e+00 1.79084596e+00 1.46457704 0.49459461 567.25 8.24875519e-01 2.51623313e+00 2.64798958e+00 1.25401453 0.67633349 567.50 1.50938715e+00 2.70205227e+00 3.09505025e+00 1.06136856 0.76036899 567.75 2.54277648e+00 2.62567445e+00 3.65511676e+00 0.80143602 0.83285821 568.00 3.15936010e+00 2.32345333e+00 3.92173325e+00 0.63410375 0.86307486 568.25 3.56973351e+00 1.86183093e+00 4.02609137e+00 0.48074663 0.87635419 568.50 3.90385281e+00 1.24545832e+00 4.09771072e+00 0.30882562 0.89272013 568.75 3.97988068e+00 5.79457732e-01 4.02184304e+00 0.14458084 0.87267346 569.00 3.93194322e+00 5.78451604e-01 3.97426518e+00 0.14606819 0.87926527 569.25 3.69048242e+00 6.70398880e-02 3.69109128e+00 0.01816362 0.89041933 569.50 3.42182302e+00 -1.28264971e-01 3.42422614e+00 -0.03746686 0.88261727 569.75 3.43793120e+00 -2.57901511e-01 3.44759106e+00 -0.07487624 0.89527179 570.00 3.30870194e+00 -3.31210640e-01 3.32523819e+00 -0.09977053 0.89117735 570.25 3.07416724e+00 -9.44006886e-01 3.21584409e+00 -0.29793699 0.83526286 570.50 3.01489677e+00 -1.43624852e+00 3.33952278e+00 -0.44457693 0.79402562 570.75 2.25299609e+00 -1.86750514e+00 2.92635726e+00 -0.69211530 0.62391388 571.00 1.12451157e+00 -1.43095746e+00 1.81993558e+00 -0.90474593 0.41769736 571.25 5.75768779e-01 -7.39775328e-01 9.37431183e-01 -0.90942647 0.29801278 571.50 2.40519374e-01 -3.52134394e-01 4.26436632e-01 -0.97154868 0.09105290 571.75 -3.38329097e-02 2.51506188e-01 2.53771607e-01 1.70451478 0.03761681 572.00 -2.15406286e-01 1.18506280e+00 1.20448068e+00 1.75060108 0.30077671 572.25 7.18018712e-02 2.76437423e+00 2.76530657e+00 1.54482816 0.67055561 572.50 1.12916743e+00 3.84420216e+00 4.00660821e+00 1.28509933 0.74766691 572.75 2.78683330e+00 5.16974816e+00 5.87305167e+00 1.07638680 0.78647378 573.00 4.62341250e+00 5.36184763e+00 7.07992607e+00 0.85921631 0.77226027 573.25 7.03268898e+00 4.28543023e+00 8.23551010e+00 0.54727250 0.72705567 573.50 9.13079531e+00 1.63237433e+00 9.27556300e+00 0.17690787 0.78240682 573.75 1.02375091e+01 1.47533787e+00 1.03432690e+01 0.14312564 0.85987258 574.00 1.15557603e+01 -2.85688878e-01 1.15592912e+01 -0.02471760 0.84370881 574.25 1.18222855e+01 -3.28874240e+00 1.22711964e+01 -0.27132171 0.88291803 574.50 1.05379066e+01 -7.16764820e+00 1.27445147e+01 -0.59729810 0.82052212 574.75 9.68834566e+00 -9.38181684e+00 1.34863831e+01 -0.76932581 0.82114496 575.00 6.53182847e+00 -1.19593245e+01 1.36268201e+01 -1.07089810 0.81435019 575.25 3.84199435e+00 -1.30399302e+01 1.35941421e+01 -1.28427059 0.85277968 575.50 9.07035635e-02 -1.33255363e+01 1.33258450e+01 -1.56398968 0.80416281 575.75 -2.78335925e+00 -1.24758593e+01 1.27825723e+01 -1.79030121 0.77490318 576.00 -4.76226920e+00 -1.07673038e+01 1.17734463e+01 -1.98722002 0.71181389 576.25 -6.90429688e+00 -8.90016873e+00 1.12642052e+01 -2.23057416 0.68173060 576.50 -6.88235685e+00 -5.46806594e+00 8.79014112e+00 -2.47021140 0.49379110 576.75 -7.13126093e+00 -1.95940869e+00 7.39555034e+00 -2.87344653 0.41623613 577.00 -4.01998585e+00 -1.36835382e+00 4.24649013e+00 -2.81350664 0.15056257 577.25 -1.35548944e+00 4.87112171e-01 1.44035756e+00 2.79660148 0.02518865 577.50 -2.57258548e+00 1.95838158e+00 3.23318024e+00 2.49093012 0.15079084 577.75 -3.74267068e+00 7.51827696e-01 3.81743745e+00 2.94335108 0.18062546 578.00 -3.19677621e+00 -7.20249832e-01 3.27690982e+00 -2.91998788 0.21880513 578.25 -3.29824282e+00 -1.68549563e+00 3.70395750e+00 -2.66916133 0.23713399 578.50 -2.85597308e+00 5.27410772e-02 2.85646003e+00 3.12312781 0.26043672 578.75 -2.75976193e+00 3.00852554e-01 2.77611206e+00 3.03300749 0.28342420 579.00 -3.17880419e+00 -2.37164966e-01 3.18763914e+00 -3.06712239 0.28672360 579.25 -2.65120087e+00 4.47910659e-01 2.68877109e+00 2.97422675 0.26345196 579.50 -3.14715872e+00 2.36233018e+00 3.93512539e+00 2.49769285 0.41949672 579.75 -2.89303163e+00 1.91417798e+00 3.46896373e+00 2.55707031 0.36364354 580.00 -1.68319408e+00 2.02884073e+00 2.63615952e+00 2.26334707 0.31675571 580.25 -8.39979387e-01 2.44493933e+00 2.58520670e+00 1.90172102 0.34558659 580.50 4.39470582e-01 2.19178516e+00 2.23540971e+00 1.37291230 0.37610440 580.75 1.07478166e+00 1.48116445e+00 1.83002835e+00 0.94307341 0.34318513 581.00 1.85253764e+00 5.66844233e-01 1.93731982e+00 0.29693632 0.49410693 581.25 1.94653441e+00 5.54381721e-02 1.94732371e+00 0.02847275 0.51309100 581.50 1.62235029e+00 -5.74768596e-01 1.72115642e+00 -0.34048392 0.42995213 581.75 9.26389733e-01 -1.08799677e+00 1.42896288e+00 -0.86545313 0.33512770 582.00 1.08775041e+00 -1.82988227e+00 2.12877196e+00 -1.03447703 0.47887517 582.25 5.78970414e-02 -2.13854926e+00 2.13933284e+00 -1.54372989 0.50966909 582.50 -9.95915517e-01 -2.16546299e+00 2.38350114e+00 -2.00185980 0.56735585 582.75 -9.05944831e-01 -1.83175875e+00 2.04354500e+00 -2.03009573 0.43501072 583.00 -1.82077711e+00 -1.28548084e+00 2.22883159e+00 -2.52684671 0.44905594 583.25 -2.35145363e+00 -1.22479149e+00 2.65131069e+00 -2.66139218 0.58849257 583.50 -1.84986274e+00 -2.60349915e-01 1.86809375e+00 -3.00177089 0.31551538 583.75 -1.49466965e+00 -2.02855185e-01 1.50837250e+00 -3.00669779 0.20232430 584.00 -1.67148156e+00 -4.54325682e-01 1.73212657e+00 -2.87619442 0.22415188 584.25 -1.92396131e+00 -1.72419063e-01 1.93167167e+00 -3.05221471 0.39494706 584.50 -1.78782992e+00 -3.63301860e-01 1.82436950e+00 -2.94111411 0.27041585 584.75 -2.29159945e+00 -8.54588914e-01 2.44576169e+00 -2.78464463 0.26825287 585.00 -1.74594133e+00 -6.39715147e-01 1.85944792e+00 -2.79038181 0.10062917 585.25 -4.89917860e+00 -5.04815153e-01 4.92511820e+00 -3.03891425 0.36978660 585.50 -6.88423238e+00 -8.28304779e-01 6.93388378e+00 -3.02184915 0.53563898 585.75 -7.59730007e+00 1.45357603e+00 7.73510514e+00 2.95254932 0.47836948 586.00 -6.82204544e+00 6.61380206e+00 9.50171993e+00 2.37169234 0.63342720 586.25 -5.43126001e+00 9.12879563e+00 1.06223112e+01 2.10750104 0.70541903 586.50 -3.39090223e+00 1.04995683e+01 1.10335467e+01 1.88317870 0.72726438 586.75 1.91867356e+00 9.90103597e+00 1.00852279e+01 1.37938368 0.67674032 587.00 6.11599234e+00 1.08404374e+01 1.24467042e+01 1.05712917 0.72236193 587.25 1.08085472e+01 8.70408817e+00 1.38775302e+01 0.67796235 0.73814311 587.50 1.26072149e+01 6.43710962e+00 1.41555024e+01 0.47208316 0.69625956 587.75 1.35182949e+01 -2.19008101e+00 1.36945519e+01 -0.16061318 0.63116898 588.00 1.03133615e+01 -5.14646864e+00 1.15261253e+01 -0.46285515 0.53797952 588.25 2.74966267e+00 -7.92768455e+00 8.39099679e+00 -1.23693666 0.40399034 588.50 -2.60209045e-01 -9.10500237e+00 9.10871983e+00 -1.59936724 0.40337039 588.75 -6.21721114e+00 -2.18388025e+00 6.58961663e+00 -2.80379254 0.15719808 589.00 -7.72407796e+00 -9.58526309e-01 7.78332532e+00 -3.01812796 0.24433491 589.25 -8.80099560e+00 -5.32150411e-01 8.81706911e+00 -3.08120138 0.19516263 589.50 -8.34863021e+00 2.34075294e+00 8.67056807e+00 2.86823561 0.17319575 589.75 -8.16501654e+00 7.04613388e+00 1.07849663e+01 2.42961900 0.33604813 590.00 -6.96645550e+00 8.40117506e+00 1.09138098e+01 2.26310448 0.33299841 590.25 -4.28831155e+00 8.20660659e+00 9.25948204e+00 2.05231591 0.25146118 590.50 -3.73305196e+00 9.65114847e+00 1.03479633e+01 1.93987075 0.24815014 590.75 -1.53217078e+00 1.33662167e+01 1.34537465e+01 1.68492827 0.40010566 591.00 9.71884115e-01 1.41110200e+01 1.41444492e+01 1.50203080 0.54908382 591.25 5.72902992e+00 1.20388036e+01 1.33324632e+01 1.12662996 0.51995034 591.50 6.19689891e+00 1.28692867e+01 1.42835603e+01 1.12203667 0.61534533 591.75 8.33930391e+00 1.28774630e+01 1.53418722e+01 0.99611785 0.72157662 592.00 8.90055294e+00 1.22575847e+01 1.51482087e+01 0.94275037 0.73936727 592.25 8.16637883e+00 1.32008467e+01 1.55226318e+01 1.01679415 0.78785453 592.50 9.66573332e+00 1.31333272e+01 1.63067680e+01 0.93633512 0.78120959 592.75 1.27774027e+01 1.36472724e+01 1.86951882e+01 0.81830512 0.83004419 593.00 1.47436981e+01 1.40799157e+01 2.03867766e+01 0.76237312 0.86088912 593.25 1.76249388e+01 1.35826846e+01 2.22514672e+01 0.65658756 0.87523085 593.50 2.17456335e+01 1.19832908e+01 2.48288508e+01 0.50366168 0.84572102 593.75 2.62802206e+01 9.08573271e+00 2.78064836e+01 0.33286141 0.85679824 594.00 3.02181805e+01 2.52856963e+00 3.03237876e+01 0.08348262 0.81767301 594.25 3.15815788e+01 -5.03982787e+00 3.19811817e+01 -0.15824694 0.80049737 594.50 2.84581616e+01 -1.07816174e+01 3.04320593e+01 -0.36214920 0.82686026 594.75 2.65062587e+01 -1.24203027e+01 2.92719263e+01 -0.43819717 0.82246152 595.00 2.38608930e+01 -1.34580109e+01 2.73945300e+01 -0.51354305 0.84667696 595.25 2.23029889e+01 -1.45282704e+01 2.66175497e+01 -0.57736203 0.86023087 595.50 2.31548800e+01 -1.77768733e+01 2.91918771e+01 -0.65475690 0.87808834 595.75 2.26055715e+01 -1.85397417e+01 2.92358322e+01 -0.68690158 0.85165241 596.00 1.90598574e+01 -2.28394428e+01 2.97475766e+01 -0.87536108 0.79642467 596.25 1.76290400e+01 -2.53377164e+01 3.08671820e+01 -0.96291980 0.84489298 596.50 1.68512541e+01 -2.75858980e+01 3.23256327e+01 -1.02242628 0.87097444 596.75 1.49057835e+01 -3.03794586e+01 3.38392359e+01 -1.11465395 0.83943706 597.00 1.00528513e+01 -3.53135846e+01 3.67166049e+01 -1.29345892 0.84488938 597.25 6.71294771e+00 -3.93290327e+01 3.98978255e+01 -1.40173871 0.85013279 597.50 -8.69255112e+00 -3.77269768e+01 3.87154391e+01 -1.79725102 0.80812190 597.75 -1.41634559e+01 -3.38796581e+01 3.67210391e+01 -1.96676719 0.84150799 598.00 -2.02870398e+01 -2.95290642e+01 3.58263815e+01 -2.17275725 0.82332058 598.25 -2.31648971e+01 -2.65259417e+01 3.52170136e+01 -2.28865824 0.86758199 598.50 -2.31719660e+01 -2.17520886e+01 3.17819661e+01 -2.38779014 0.87326450 598.75 -2.26655545e+01 -1.74948448e+01 2.86320966e+01 -2.48424150 0.87132913 599.00 -2.31360062e+01 -1.38232908e+01 2.69510324e+01 -2.60302848 0.83970084 599.25 -2.35192630e+01 -1.24183086e+01 2.65964306e+01 -2.65579219 0.82251395 599.50 -2.32584644e+01 -6.12980084e+00 2.40526636e+01 -2.88390096 0.75651748 599.75 -2.14822040e+01 -2.36171193e+00 2.16116351e+01 -3.03209432 0.73171623 600.00 -1.81476696e+01 3.27298781e+00 1.84404544e+01 2.96315775 0.63229989 600.25 -1.65611519e+01 4.76381696e+00 1.72326929e+01 2.86150420 0.66089889 600.50 -1.54572779e+01 3.24916044e+00 1.57950779e+01 2.93440640 0.76185554 600.75 -1.38524575e+01 3.41015501e+00 1.42660343e+01 2.90021543 0.73560563 601.00 -1.27587231e+01 4.62116909e+00 1.35698275e+01 2.79409365 0.68954976 601.25 -1.10255624e+01 5.72295551e+00 1.24223688e+01 2.66281164 0.55517596 601.50 -6.68250853e+00 8.54823952e+00 1.08502682e+01 2.23430409 0.51356939 601.75 -5.34866874e+00 9.42212935e+00 1.08344256e+01 2.08710516 0.53392827 602.00 -6.06209768e-01 1.02743846e+01 1.02922529e+01 1.62973005 0.55022219 602.25 2.50354356e+00 6.73665477e+00 7.18681069e+00 1.21498337 0.35426153 602.50 3.81634693e+00 5.51950643e+00 6.71039902e+00 0.96584589 0.34177079 602.75 4.16707581e+00 2.13283136e+00 4.68118472e+00 0.47306618 0.26691117 603.00 2.71445977e+00 -1.57692145e+00 3.13926315e+00 -0.52628226 0.26250992 603.25 8.54778019e-01 -2.85941210e+00 2.98444015e+00 -1.28031699 0.26486384 603.50 -1.24046534e+00 -3.93677623e+00 4.12758541e+00 -1.87604515 0.49579724 603.75 -3.09302681e+00 -2.74487202e+00 4.13535213e+00 -2.41576094 0.50019406 604.00 -4.03701790e+00 -2.41614048e+00 4.70481118e+00 -2.60227951 0.68973858 604.25 -4.38612486e+00 -1.69632716e+00 4.70272444e+00 -2.77256193 0.72613272 604.50 -4.65994356e+00 -8.35914828e-01 4.73432440e+00 -2.96409738 0.78475029 604.75 -4.89207621e+00 -6.41929195e-01 4.93401284e+00 -3.01111993 0.78450324 605.00 -4.88981097e+00 -7.52093545e-02 4.89038932e+00 -3.12621304 0.77071518 605.25 -5.53951981e+00 1.09047703e+00 5.64583208e+00 2.94722385 0.78904385 605.50 -5.60093297e+00 2.24414201e+00 6.03379014e+00 2.76050633 0.78647267 605.75 -4.56338945e+00 3.59640178e+00 5.81021764e+00 2.47415078 0.75176543 606.00 -3.72020700e+00 4.17705870e+00 5.59354624e+00 2.29840954 0.78616426 606.25 -2.36029137e+00 4.61146020e+00 5.18039965e+00 2.04386441 0.79762155 606.50 -1.49353497e+00 4.74284970e+00 4.97245111e+00 1.87586840 0.84544278 606.75 7.56478290e-02 4.24205716e+00 4.24273162e+00 1.55296540 0.73083549 607.00 1.19545629e+00 4.06667027e+00 4.23874071e+00 1.28488594 0.77887130 607.25 1.92799387e+00 3.11261836e+00 3.66135950e+00 1.01622528 0.66268234 607.50 2.84474821e+00 2.29890996e+00 3.65753734e+00 0.67967515 0.66949224 607.75 3.55040130e+00 9.80980095e-01 3.68343200e+00 0.26957551 0.67541343 608.00 3.53631533e+00 5.17658171e-01 3.57400282e+00 0.14535115 0.67401590 608.25 3.19206645e+00 -9.75760271e-01 3.33787302e+00 -0.29666232 0.52864364 608.50 3.02373590e+00 -1.86023211e+00 3.55013272e+00 -0.55152821 0.61463273 608.75 2.37675069e+00 -2.47498168e+00 3.43139595e+00 -0.80564198 0.67321486 609.00 2.02110651e+00 -2.87690172e+00 3.51588325e+00 -0.95837515 0.70123867 609.25 1.98515595e+00 -3.32896242e+00 3.87593020e+00 -1.03308066 0.74685382 609.50 1.40952088e+00 -3.55741929e+00 3.82648417e+00 -1.19355276 0.75004499 609.75 1.61380200e-02 -3.96480203e+00 3.96483487e+00 -1.56672603 0.78758234 610.00 -5.66842592e-01 -4.58859172e+00 4.62347104e+00 -1.69370665 0.83646867 610.25 -1.68305467e+00 -5.19697708e+00 5.46271395e+00 -1.88399011 0.86858080 610.50 -2.35120455e+00 -4.98197158e+00 5.50892037e+00 -2.01174713 0.84775771 610.75 -4.17573146e+00 -3.89116233e+00 5.70770335e+00 -2.39145604 0.85643672 611.00 -4.66490715e+00 -3.18137612e+00 5.64646019e+00 -2.54306290 0.87794588 611.25 -5.03408325e+00 -1.79526889e+00 5.34462203e+00 -2.79903001 0.88409134 611.50 -4.91673887e+00 -8.11240450e-01 4.98321505e+00 -2.97807028 0.83240448 611.75 -4.43316427e+00 5.18109763e-01 4.46333768e+00 3.02524913 0.79429973 612.00 -4.17986586e+00 1.28629048e+00 4.37330788e+00 2.84305484 0.79759488 612.25 -3.14327222e+00 1.93755436e+00 3.69246220e+00 2.58919199 0.69495255 612.50 -2.25164784e+00 1.74961557e+00 2.85150358e+00 2.48101069 0.52117886 612.75 -8.18106861e-01 1.46272048e+00 1.67596242e+00 2.08075540 0.24863924 613.00 -8.48314896e-02 1.21991560e+00 1.22286158e+00 1.64022338 0.16096356 613.25 8.04430687e-02 2.28223371e-01 2.41985526e-01 1.23191817 0.00718119 613.50 2.65974706e-01 -3.88966809e-01 4.71208789e-01 -0.97102719 0.02840450 613.75 -3.16399146e-01 -8.74959610e-01 9.30409985e-01 -1.91778151 0.13432126 614.00 -1.04325509e+00 -7.55854945e-01 1.28829262e+00 -2.51460182 0.25101995 614.25 -1.80082566e+00 -2.68199363e-02 1.80102536e+00 -3.12670062 0.46299586 614.50 -1.67040343e+00 6.30518113e-01 1.78544132e+00 2.78066302 0.50809857 614.75 -1.18395469e+00 1.54633928e+00 1.94754046e+00 2.22423844 0.53582509 615.00 -2.00885410e-01 1.46263900e+00 1.47636980e+00 1.70728686 0.39389010 615.25 5.09468048e-01 1.11840226e+00 1.22897572e+00 1.14335150 0.37056603 615.50 4.62516282e-01 7.74414010e-01 9.02019051e-01 1.03240370 0.32508179 615.75 2.72019846e-01 6.49697875e-01 7.04345175e-01 1.17428525 0.29576676 616.00 6.19599586e-01 6.01939266e-01 8.63848671e-01 0.77094173 0.39661856 616.25 7.96896990e-01 4.35775867e-01 9.08265060e-01 0.50041456 0.40448282 616.50 7.91438816e-01 3.05164810e-01 8.48234025e-01 0.36801589 0.46186411 616.75 8.62884401e-01 1.80459866e-01 8.81552752e-01 0.20616418 0.59095826 617.00 9.81112643e-01 3.53690534e-02 9.81749962e-01 0.03603434 0.64727512 617.25 1.04903888e+00 2.35371368e-02 1.04930289e+00 0.02243309 0.68598716 617.50 1.36074214e+00 -6.42368452e-02 1.36225752e+00 -0.04717219 0.74391055 617.75 1.46386347e+00 -1.05087034e-01 1.46763059e+00 -0.07166452 0.82353398 618.00 1.52062762e+00 -4.96973524e-01 1.59977844e+00 -0.31587834 0.82658323 618.25 1.68868218e+00 -5.81511505e-01 1.78600200e+00 -0.33163988 0.87138861 618.50 1.75151659e+00 -8.13870208e-01 1.93137129e+00 -0.43498302 0.82280298 618.75 1.78283677e+00 -9.15938270e-01 2.00435772e+00 -0.47458961 0.85438834 619.00 1.71573335e+00 -1.08068808e+00 2.02771489e+00 -0.56209331 0.79437920 619.25 1.65362372e+00 -1.02142786e+00 1.94365282e+00 -0.55332585 0.77383310 619.50 1.92368756e+00 -7.89615281e-01 2.07943890e+00 -0.38949919 0.81849850 619.75 2.14921479e+00 -6.01817433e-01 2.23188450e+00 -0.27302479 0.80452868 620.00 3.05009517e+00 -6.43030376e-01 3.11714109e+00 -0.20778035 0.84452960 620.25 3.58545844e+00 -9.17152632e-01 3.70090275e+00 -0.25042799 0.85605448 620.50 4.60719555e+00 -1.73145256e+00 4.92180645e+00 -0.35948488 0.91173156 620.75 4.85015095e+00 -2.45864887e+00 5.43773101e+00 -0.46916997 0.92635847 621.00 4.78072165e+00 -3.60552151e+00 5.98791157e+00 -0.64617053 0.92920800 621.25 4.68238560e+00 -4.34977360e+00 6.39103006e+00 -0.74858949 0.88779052 621.50 4.55519874e+00 -6.66194642e+00 8.07040059e+00 -0.97105036 0.91443704 621.75 3.99300352e+00 -7.57256771e+00 8.56083283e+00 -1.08554918 0.90187162 622.00 3.22867543e+00 -8.98774992e+00 9.55007820e+00 -1.22592198 0.90590876 622.25 2.28794248e+00 -9.42596850e+00 9.69966819e+00 -1.33267392 0.88695496 622.50 4.13088711e-01 -1.03073368e+01 1.03156112e+01 -1.53074061 0.88641004 622.75 -5.35030016e-01 -1.03904709e+01 1.04042368e+01 -1.62224326 0.84975377 623.00 -2.70858406e+00 -9.80799479e+00 1.01751260e+01 -1.84024144 0.76283755 623.25 -4.10901991e+00 -8.97597255e+00 9.87178443e+00 -2.00010116 0.71325963 623.50 -4.54427848e+00 -7.63812896e+00 8.88771517e+00 -2.10749177 0.71686356 623.75 -5.95269719e+00 -6.66395778e+00 8.93548752e+00 -2.29987936 0.71861062 624.00 -6.94726079e+00 -5.64902985e+00 8.95410357e+00 -2.45889641 0.78360141 624.25 -6.23021768e+00 -4.95943613e+00 7.96314128e+00 -2.46927753 0.69255070 624.50 -5.22086759e+00 -3.03229340e+00 6.03757084e+00 -2.61540851 0.58533626 624.75 -4.60814835e+00 -3.26240174e+00 5.64608682e+00 -2.52554190 0.61321561 625.00 -4.06293082e+00 -3.08127134e+00 5.09918032e+00 -2.49274584 0.64106463 625.25 -3.34210376e+00 -2.82995439e+00 4.37930353e+00 -2.43898353 0.63122546 625.50 -3.39557136e+00 -2.75435817e+00 4.37222984e+00 -2.46008263 0.66347672 625.75 -3.64346368e+00 -3.35305029e+00 4.95154258e+00 -2.39767897 0.70466945 626.00 -3.22994820e+00 -3.39434766e+00 4.68552680e+00 -2.33138193 0.77567028 626.25 -3.44315449e+00 -3.67207743e+00 5.03383208e+00 -2.32403194 0.75542096 626.50 -3.30071038e+00 -3.85357358e+00 5.07392534e+00 -2.27907055 0.79879893 626.75 -3.17235520e+00 -4.48808827e+00 5.49606894e+00 -2.18609740 0.78225749 627.00 -3.23537061e+00 -4.85218351e+00 5.83192145e+00 -2.15888191 0.80789397 627.25 -4.72123257e+00 -4.99241748e+00 6.87126402e+00 -2.32828382 0.86715499 627.50 -5.16348411e+00 -4.98725302e+00 7.17873671e+00 -2.37355415 0.89562892 627.75 -5.30337049e+00 -4.59656686e+00 7.01813120e+00 -2.42746831 0.84081255 628.00 -5.05416177e+00 -4.42606919e+00 6.71823189e+00 -2.42235069 0.81060181 628.25 -5.51835916e+00 -4.64160339e+00 7.21087858e+00 -2.44227641 0.70765725 628.50 -6.05904609e+00 -4.90870359e+00 7.79791064e+00 -2.46069651 0.72916112 628.75 -6.84792454e+00 -4.22067455e+00 8.04413850e+00 -2.58924239 0.70047153 629.00 -7.13733467e+00 -3.33129274e+00 7.87648764e+00 -2.70490376 0.72785877 629.25 -5.86655646e+00 -1.73763827e+00 6.11848604e+00 -2.85363134 0.60806728 629.50 -4.86016825e+00 -1.80107803e+00 5.18315710e+00 -2.78670324 0.44553301 629.75 -6.19827108e+00 -3.38661352e+00 7.06312364e+00 -2.64153269 0.61463764 630.00 -7.18450762e+00 -3.31675593e+00 7.91315485e+00 -2.70908972 0.59113930 630.25 -1.07525143e+01 -2.35238873e+00 1.10068295e+01 -2.92621044 0.58062992 630.50 -1.10923317e+01 -1.10108379e+00 1.11468474e+01 -3.04265147 0.56566730 630.75 -9.75594762e+00 2.01039661e+00 9.96093412e+00 2.93836856 0.48059472 631.00 -8.89136135e+00 3.03080467e+00 9.39372575e+00 2.81307387 0.53689369 631.25 -6.46824284e+00 3.35624231e+00 7.28714813e+00 2.66295532 0.42710528 631.50 -5.32645060e+00 2.54988096e+00 5.90533393e+00 2.69511312 0.31668408 631.75 -4.36286750e+00 6.44577482e-01 4.41022595e+00 2.99491204 0.32382466 632.00 -5.37635443e+00 1.27574815e+00 5.52564207e+00 2.90861288 0.44742044 632.25 -5.03205247e+00 7.60521997e-01 5.08919893e+00 2.99159233 0.37627472 632.50 -5.90125788e+00 1.09083468e+00 6.00123028e+00 2.95880803 0.47189519 632.75 -6.41455629e+00 1.05017133e+00 6.49995325e+00 2.97931538 0.54524613 633.00 -6.79878125e+00 1.67442040e+00 7.00193617e+00 2.90011592 0.62604836 633.25 -6.82092220e+00 7.44433874e-01 6.86142562e+00 3.03288315 0.66695240 633.50 -6.35338432e+00 5.47580373e-01 6.37693787e+00 3.05561792 0.64072076 633.75 -5.88091512e+00 8.15752497e-01 5.93722281e+00 3.00376034 0.63419438 634.00 -5.84026585e+00 6.61349449e-01 5.87759205e+00 3.02883338 0.65223951 634.25 -6.65478406e+00 3.17368867e-01 6.66234747e+00 3.09393843 0.76870251 634.50 -7.27055306e+00 -9.19550351e-02 7.27113454e+00 -3.12894573 0.70879356 634.75 -7.99869454e+00 -1.06521827e+00 8.06931250e+00 -3.00919766 0.72873586 635.00 -8.42670760e+00 -1.05686487e+00 8.49272420e+00 -3.01682564 0.69462942 635.25 -8.39557076e+00 5.58428654e-01 8.41412211e+00 3.07517581 0.66853836 635.50 -9.26589235e+00 1.91111399e+00 9.46092584e+00 2.93819231 0.63660988 635.75 -1.15266715e+01 2.58848966e+00 1.18137392e+01 2.92069207 0.78921435 636.00 -1.17414853e+01 3.52159211e+00 1.22582253e+01 2.85020255 0.77624319 636.25 -1.08861057e+01 3.72844991e+00 1.15068952e+01 2.81161831 0.75289293 636.50 -1.00936586e+01 4.32807604e+00 1.09824490e+01 2.73651487 0.69673032 636.75 -9.73601373e+00 4.81190149e+00 1.08602191e+01 2.68256579 0.64616844 637.00 -1.09553439e+01 5.81708633e+00 1.24039531e+01 2.65346803 0.68231788 637.25 -1.27264699e+01 6.78784451e+00 1.44235179e+01 2.65161123 0.80515832 637.50 -1.14430672e+01 6.13388073e+00 1.29833847e+01 2.64953457 0.69494630 637.75 -1.11969922e+01 6.54994666e+00 1.29720637e+01 2.61229513 0.64693514 638.00 -1.29598615e+01 8.44929272e+00 1.54708939e+01 2.56384182 0.58319031 638.25 -1.23439038e+01 1.16321808e+01 1.69611200e+01 2.38587048 0.51687659 638.50 -4.37421264e+00 1.57987418e+01 1.63931077e+01 1.84090111 0.40757185 638.75 1.75342809e+00 2.00963232e+01 2.01726725e+01 1.48376554 0.54236864 639.00 7.16380890e+00 1.85274318e+01 1.98641860e+01 1.20184295 0.61454804 639.25 1.01488318e+01 1.58734373e+01 1.88405095e+01 1.00193770 0.64242789 639.50 1.14809525e+01 1.18866061e+01 1.65258487e+01 0.80275611 0.80664316 639.75 1.18686243e+01 9.43093113e+00 1.51593768e+01 0.67144589 0.81208535 640.00 1.05294741e+01 6.50829299e+00 1.23785177e+01 0.55362385 0.81943192 640.25 9.89186097e+00 6.01244189e+00 1.15757665e+01 0.54614752 0.83799563 640.50 8.83473974e+00 5.00999687e+00 1.01564115e+01 0.51586119 0.80898395 640.75 7.99870606e+00 4.91955629e+00 9.39049161e+00 0.55140790 0.81134335 641.00 6.58440494e+00 4.36472187e+00 7.89969527e+00 0.58538192 0.83367280 641.25 5.96715332e+00 4.48988303e+00 7.46766151e+00 0.64505641 0.81136719 641.50 5.92295168e+00 4.56394273e+00 7.47736115e+00 0.65652521 0.75073203 641.75 5.68340214e+00 4.64572824e+00 7.34056202e+00 0.68527318 0.75288947 642.00 5.57792472e+00 4.79096879e+00 7.35300117e+00 0.70964754 0.79792542 642.25 5.65650598e+00 4.98283928e+00 7.53821910e+00 0.72216414 0.83050044 642.50 5.87935014e+00 4.57974922e+00 7.45257412e+00 0.66177625 0.87599537 642.75 5.83676331e+00 4.02207991e+00 7.08836601e+00 0.60336909 0.87894552 643.00 5.18541659e+00 3.21512052e+00 6.10127406e+00 0.55501833 0.91398558 643.25 4.96761759e+00 2.92290604e+00 5.76373179e+00 0.53184042 0.90820839 643.50 4.62011906e+00 2.56507984e+00 5.28442378e+00 0.50682507 0.90363497 643.75 4.57450086e+00 2.39871960e+00 5.16526029e+00 0.48295104 0.89292824 644.00 4.36455628e+00 2.16176027e+00 4.87058096e+00 0.45987972 0.85880039 644.25 4.23648404e+00 1.96256845e+00 4.66899046e+00 0.43382118 0.85061349 644.50 4.13934051e+00 1.80240154e+00 4.51473047e+00 0.41067341 0.86118130 644.75 4.17063936e+00 1.45049776e+00 4.41567395e+00 0.33470274 0.79867715 645.00 3.91584469e+00 7.53116046e-01 3.98760874e+00 0.19000528 0.82362375 645.25 3.07640518e+00 3.55412817e-01 3.09686730e+00 0.11501871 0.58481290 645.50 1.82893857e+00 1.09876222e-01 1.83223608e+00 0.06000438 0.32860795 645.75 1.39361490e+00 1.40585456e-01 1.40068796e+00 0.10053815 0.19278325 646.00 9.11645026e-01 6.24890337e-01 1.10525318e+00 0.60089640 0.11496963 646.25 -1.15940403e-02 8.24341102e-01 8.24422631e-01 1.58486001 0.04514965 646.50 -1.34285758e+00 5.77028694e-01 1.46158427e+00 2.73574605 0.12151116 646.75 -2.43564500e+00 2.72212827e+00 3.65271801e+00 2.30070752 0.37796552 647.00 -2.23762419e+00 4.90747486e+00 5.39353979e+00 1.99859754 0.60930831 647.25 -1.95620823e+00 4.30300259e+00 4.72679404e+00 1.99748121 0.54339500 647.50 -1.00479910e+00 4.65604094e+00 4.76322774e+00 1.78334224 0.47304775 647.75 -9.82953713e-01 3.37126014e+00 3.51163679e+00 1.85450009 0.26988169 648.00 -2.76350992e+00 3.11735906e+00 4.16592301e+00 2.29609741 0.33401021 648.25 -3.78389037e+00 7.50234154e+00 8.40255645e+00 2.03792685 0.63326568 648.50 -3.38223479e+00 1.12755638e+01 1.17719094e+01 1.86221778 0.76350444 648.75 1.67235040e+00 1.21970945e+01 1.23112091e+01 1.43453540 0.69862630 649.00 4.82638998e+00 1.14652503e+01 1.24396947e+01 1.17235418 0.69722444 649.25 6.50206780e+00 7.60917167e+00 1.00088151e+01 0.86369325 0.65912561 649.50 7.62546002e+00 5.26889379e+00 9.26870445e+00 0.60463358 0.69249930 649.75 7.43835400e+00 2.30736249e+00 7.78800565e+00 0.30078629 0.62917407 650.00 6.13939595e+00 1.18978553e+00 6.25362073e+00 0.19142236 0.59796862 650.25 3.01403207e+00 3.45631883e-02 3.01423024e+00 0.01146692 0.32204894 650.50 1.76605657e+00 7.04927366e-01 1.90154632e+00 0.37977628 0.17333442 650.75 -4.05263994e-01 1.38478332e+00 1.44286650e+00 1.85550120 0.13798768 651.00 -9.18890475e-01 2.07203837e+00 2.26665011e+00 1.98820811 0.30035532 651.25 -1.05046884e+00 3.29232051e+00 3.45584420e+00 1.87965216 0.48007008 651.50 -5.91200263e-01 3.75147972e+00 3.79777801e+00 1.72710206 0.47917770 651.75 -9.85040929e-01 4.09068436e+00 4.20761265e+00 1.80709855 0.48370292 652.00 -1.53899755e+00 4.23434003e+00 4.50534670e+00 1.91940829 0.49549264 652.25 -2.88563570e+00 3.10628018e+00 4.23979598e+00 2.31938743 0.46779610 652.50 -3.41447138e+00 4.86404752e+00 5.94285900e+00 2.18285092 0.59668445 652.75 -2.86727439e+00 7.43191763e+00 7.96584347e+00 1.93900646 0.76695261 653.00 -1.99988102e+00 7.62014974e+00 7.87821085e+00 1.82745453 0.73554107 653.25 7.74971530e-01 5.50088297e+00 5.55520425e+00 1.43083613 0.45133530 653.50 3.11367956e+00 3.55611656e+00 4.72662304e+00 0.85163553 0.31984680 653.75 5.47911620e+00 1.28143221e+00 5.62696924e+00 0.22974625 0.56208532 654.00 5.36831863e+00 -1.67625419e+00 5.62393751e+00 -0.30265653 0.46595656 654.25 3.81873240e+00 -8.12321029e+00 8.97603825e+00 -1.13135240 0.71544718 654.50 1.63860332e+00 -1.02984994e+01 1.04280444e+01 -1.41300811 0.73401848 654.75 -3.93790787e+00 -1.12672218e+01 1.19355521e+01 -1.90702674 0.69818776 655.00 -8.15175128e+00 -9.74441656e+00 1.27045151e+01 -2.26743356 0.75654670 655.25 -1.01295128e+01 -7.21242399e+00 1.24348739e+01 -2.52284450 0.83814002 655.50 -9.44825603e+00 -6.16336833e+00 1.12808090e+01 -2.56358215 0.80367585 655.75 -9.26697956e+00 -5.86107559e+00 1.09649039e+01 -2.57764052 0.78125618 656.00 -8.97965731e+00 -4.67960077e+00 1.01258535e+01 -2.66118149 0.68558717 656.25 -8.43640391e+00 -3.23159360e+00 9.03416339e+00 -2.77578019 0.62988992 656.50 -7.26576297e+00 -2.83193522e+00 7.79815161e+00 -2.76994116 0.47609478 656.75 -5.62878245e+00 -3.91455615e+00 6.85616086e+00 -2.53392459 0.34749870 657.00 -1.52718956e+00 -5.07973385e+00 5.30433822e+00 -1.86284349 0.10626562 657.25 -6.97437125e-01 -6.98755951e+00 7.02227930e+00 -1.67027811 0.10581741 657.50 -1.52187900e+00 -1.02553309e+01 1.03676385e+01 -1.71811996 0.17613764 657.75 -3.24720501e+00 -1.02712863e+01 1.07723564e+01 -1.87699750 0.19070496 658.00 -9.41901225e+00 -6.89227175e+00 1.16713839e+01 -2.50988048 0.26578920 658.25 -1.02242522e+01 -3.83886017e+00 1.09211804e+01 -2.78241341 0.24316485 658.50 -1.05376708e+01 7.23451495e-01 1.05624754e+01 3.07304638 0.29720200 658.75 -8.62396637e+00 1.31365387e+00 8.72344442e+00 2.99042872 0.25620167 659.00 -7.37066394e+00 1.87173034e-01 7.37304013e+00 3.11620379 0.30877187 659.25 -6.51731192e+00 -3.79191697e-01 6.52833371e+00 -3.08347595 0.33276926 659.50 -5.21735462e+00 -3.04221484e-01 5.22621660e+00 -3.08334908 0.31645098 659.75 -5.54458981e+00 -2.28685609e-01 5.54930386e+00 -3.10037120 0.34028176 660.00 -6.61281590e+00 2.54413855e-01 6.61770810e+00 3.10313877 0.38853996 660.25 -5.43146838e+00 1.87967584e-01 5.43471992e+00 3.10699932 0.35407810 660.50 -3.90006329e+00 -9.42938919e-01 4.01243411e+00 -2.90436975 0.22834741 660.75 -3.26333060e+00 -2.75683525e+00 4.27193951e+00 -2.44012994 0.22232967 661.00 -2.19981077e+00 -6.29459774e+00 6.66791783e+00 -1.90700425 0.37257411 661.25 -2.12152733e+00 -7.43801608e+00 7.73465975e+00 -1.84864595 0.44306200 661.50 -3.37189040e+00 -1.14380546e+01 1.19247112e+01 -1.85747181 0.57394705 661.75 -2.81390789e+00 -1.16425644e+01 1.19777870e+01 -1.80793999 0.52610951 662.00 -1.28515589e+00 -1.09536656e+01 1.10287994e+01 -1.68758893 0.35136387 662.25 -3.13869449e+00 -1.09529474e+01 1.13937904e+01 -1.84987921 0.45922790 662.50 -4.86775012e+00 -1.10919141e+01 1.21130322e+01 -1.98434413 0.41171328 662.75 -3.59019926e+00 -1.18104224e+01 1.23440515e+01 -1.86590568 0.41908630 663.00 -6.52069133e+00 -1.30390251e+01 1.45786005e+01 -2.03451626 0.67518330 663.25 -6.57406922e+00 -1.29144381e+01 1.44914147e+01 -2.04165613 0.73510178 663.50 -4.84603940e+00 -1.26408055e+01 1.35378751e+01 -1.93688024 0.71486204 663.75 -4.19934568e+00 -1.32160920e+01 1.38672128e+01 -1.87845230 0.76108709 664.00 -1.47498839e+00 -1.26964667e+01 1.27818566e+01 -1.68645103 0.81814555 664.25 1.48989401e-01 -1.24153470e+01 1.24162410e+01 -1.55879648 0.78732668 664.50 3.56954658e+00 -1.16835677e+01 1.22166860e+01 -1.27428437 0.63212757 664.75 5.44950333e+00 -1.05830778e+01 1.19037230e+01 -1.09527924 0.62613404 665.00 4.98154063e+00 -7.05949572e+00 8.64015201e+00 -0.95628777 0.46140747 665.25 5.31188480e+00 -3.88284647e+00 6.57971252e+00 -0.63121247 0.29107035 665.50 6.39938451e+00 -3.09340810e-01 6.40685679e+00 -0.04830155 0.36675623 665.75 5.14491953e+00 1.72595857e+00 5.42670526e+00 0.32367100 0.34563003 666.00 4.83542869e+00 9.98180088e-01 4.93738130e+00 0.20357104 0.38028674 666.25 5.04707005e+00 -1.14809341e+00 5.17600566e+00 -0.22367103 0.46011913 666.50 4.86827904e+00 -1.32025826e+00 5.04412754e+00 -0.26482632 0.47741969 666.75 5.68433826e+00 3.65082785e-01 5.69605011e+00 0.06413799 0.48145700 667.00 6.10207560e+00 1.17308610e+00 6.21381184e+00 0.18992666 0.58851662 667.25 5.41506170e+00 6.40483423e-01 5.45280774e+00 0.11773116 0.51797140 667.50 5.13342315e+00 4.11968884e-01 5.14992734e+00 0.08008065 0.47423287 667.75 4.55749414e+00 2.71446336e-01 4.56557071e+00 0.05949016 0.49134083 668.00 4.02955818e+00 4.20901287e-01 4.05148084e+00 0.10407605 0.51116039 668.25 2.93074966e+00 5.63863779e-01 2.98449928e+00 0.19007320 0.54668359 668.50 2.46784633e+00 9.43650665e-01 2.64210941e+00 0.36522350 0.57175155 668.75 1.40745567e+00 1.55528588e+00 2.09758090e+00 0.83525324 0.44152463 669.00 6.99791111e-01 1.69578334e+00 1.83449959e+00 1.17941941 0.38866672 669.25 1.00639890e-01 2.48117410e+00 2.48321431e+00 1.53025715 0.56190686 669.50 -3.58073181e-01 2.62901261e+00 2.65328546e+00 1.70616401 0.55349902 669.75 -4.30155939e-01 3.28007748e+00 3.30816300e+00 1.70119419 0.49729187 670.00 3.29576311e-01 3.68083530e+00 3.69556072e+00 1.48149601 0.44502851 670.25 1.65116465e+00 3.38264337e+00 3.76412286e+00 1.11669094 0.36659881 670.50 2.30702593e+00 4.03669319e+00 4.64943659e+00 1.05158595 0.44458520 670.75 3.70397283e+00 3.16104262e+00 4.86945635e+00 0.70647591 0.47343784 671.00 4.31483362e+00 2.20820488e+00 4.84705662e+00 0.47301967 0.57602584 671.25 4.38540059e+00 1.33817122e+00 4.58502351e+00 0.29616780 0.69708047 671.50 4.04400784e+00 7.84067228e-01 4.11931558e+00 0.19150765 0.66853636 671.75 3.29766312e+00 -4.65530358e-01 3.33036042e+00 -0.14024304 0.58706168 672.00 3.39878597e+00 -1.17638590e+00 3.59661367e+00 -0.33321358 0.62769375 672.25 2.45042700e+00 -2.99080130e+00 3.86645638e+00 -0.88438468 0.79948040 672.50 1.89731239e+00 -3.50678755e+00 3.98714851e+00 -1.07485820 0.83694147 672.75 2.67051654e-01 -4.49263932e+00 4.50056937e+00 -1.51142415 0.82251881 673.00 -6.69625795e-01 -4.73371208e+00 4.78083976e+00 -1.71132285 0.83324124 673.25 -2.09349132e+00 -5.58384994e+00 5.96339551e+00 -1.92949596 0.81816202 673.50 -2.89742278e+00 -5.54934691e+00 6.26021644e+00 -2.05198262 0.77992767 673.75 -4.16443277e+00 -4.08931571e+00 5.83652321e+00 -2.36529520 0.68839208 674.00 -4.18032036e+00 -3.88953101e+00 5.70995007e+00 -2.39221295 0.65661198 674.25 -3.14592263e+00 -4.70286406e+00 5.65807030e+00 -2.16036947 0.63197115 674.50 -3.45791952e+00 -6.02396300e+00 6.94588638e+00 -2.09189933 0.69472311 674.75 -3.39469085e+00 -8.10840747e+00 8.79034685e+00 -1.96728733 0.73950564 675.00 -3.98868668e+00 -1.11491835e+01 1.18411956e+01 -1.91436390 0.71051805 675.25 -4.32539271e+00 -1.42047604e+01 1.48487118e+01 -1.86637921 0.76776052 675.50 -4.85497154e+00 -1.51918625e+01 1.59487754e+01 -1.88011562 0.81937036 675.75 -4.24266218e+00 -1.80143723e+01 1.85072362e+01 -1.80209666 0.84042274 676.00 -3.56336815e+00 -2.01921442e+01 2.05041527e+01 -1.74547086 0.83624407 676.25 -3.32307004e+00 -2.20192345e+01 2.22685762e+01 -1.72058267 0.88099202 676.50 -2.87493479e+00 -2.05179479e+01 2.07183840e+01 -1.71000804 0.86296637 676.75 -3.97318442e+00 -1.99781314e+01 2.03693870e+01 -1.76711154 0.88371173 677.00 -3.21839383e+00 -1.95983985e+01 1.98608984e+01 -1.73356078 0.88380594 677.25 -3.18281747e+00 -1.95303304e+01 1.97879795e+01 -1.73234409 0.91755735 677.50 -4.36522745e+00 -1.85143568e+01 1.90220035e+01 -1.80234286 0.91196066 677.75 -5.55395620e+00 -1.75658162e+01 1.84229294e+01 -1.87703009 0.93217363 678.00 -5.16442848e+00 -1.62377935e+01 1.70392858e+01 -1.87872931 0.95292240 678.25 -5.09551984e+00 -1.54574516e+01 1.62756607e+01 -1.88922653 0.95578978 678.50 -5.63705743e+00 -1.35157949e+01 1.46442182e+01 -1.96593263 0.95590345 678.75 -5.47428998e+00 -1.22726689e+01 1.34382385e+01 -1.99036507 0.96132671 679.00 -5.28264770e+00 -1.09102485e+01 1.21218765e+01 -2.02171720 0.96182566 679.25 -5.26703365e+00 -1.00257020e+01 1.13250317e+01 -2.05452010 0.97107249 679.50 -5.78279069e+00 -9.06960942e+00 1.07563229e+01 -2.13840566 0.96467929 679.75 -6.18779342e+00 -8.15807175e+00 1.02392833e+01 -2.21970719 0.95708194 680.00 -6.40137169e+00 -6.76662539e+00 9.31476134e+00 -2.32846362 0.93104305 680.25 -6.00561473e+00 -6.02175532e+00 8.50464258e+00 -2.35485250 0.92118633 680.50 -5.51619833e+00 -5.47018353e+00 7.76861325e+00 -2.36038281 0.93525994 680.75 -5.47728514e+00 -5.26236350e+00 7.59559887e+00 -2.37620380 0.91995284 681.00 -5.38166610e+00 -3.64616165e+00 6.50052496e+00 -2.54611695 0.89226620 681.25 -5.34098484e+00 -3.17589438e+00 6.21388962e+00 -2.60513317 0.89431043 681.50 -4.71851132e+00 -2.57799943e+00 5.37684203e+00 -2.64154941 0.76593498 681.75 -4.17353496e+00 -2.23569062e+00 4.73462846e+00 -2.64980799 0.72179995 682.00 -3.11208049e+00 -1.10905727e+00 3.30379373e+00 -2.79925284 0.61626290 682.25 -2.08301391e+00 -6.25736866e-01 2.17496979e+00 -2.84976915 0.36019317 682.50 -1.04920835e+00 -1.30240072e+00 1.67244905e+00 -2.24893995 0.29317719 682.75 -9.70200261e-01 -1.70080533e+00 1.95806724e+00 -2.08919373 0.39391541 683.00 5.24454770e-01 -1.64014730e+00 1.72195702e+00 -1.26131040 0.27431936 683.25 1.46286104e+00 -1.82436410e+00 2.33843255e+00 -0.89493013 0.37866381 683.50 1.85426687e+00 -2.70256777e+00 3.27752623e+00 -0.96945143 0.60875533 683.75 1.85002764e+00 -3.05789951e+00 3.57398261e+00 -1.02670884 0.62181420 684.00 2.11903303e+00 -3.38725493e+00 3.99547206e+00 -1.01177281 0.58062138 684.25 2.13292464e+00 -3.96647628e+00 4.50358764e+00 -1.07741611 0.64759343 684.50 2.52963603e+00 -5.16957361e+00 5.75530622e+00 -1.11571976 0.71721008 684.75 3.04114013e+00 -6.08819643e+00 6.80548816e+00 -1.10753749 0.75475175 685.00 3.07520161e+00 -7.62588684e+00 8.22259175e+00 -1.18748429 0.84271037 685.25 2.38142886e+00 -7.68757729e+00 8.04798410e+00 -1.27039480 0.80239276 685.50 1.61663090e+00 -8.92748886e+00 9.07268168e+00 -1.39165301 0.76997820 685.75 8.18781601e-01 -9.65243361e+00 9.68709853e+00 -1.48617247 0.68863833 686.00 -2.16660870e+00 -1.01123602e+01 1.03418577e+01 -1.78185887 0.56945388 686.25 -7.23518614e+00 -1.01598622e+01 1.24727991e+01 -2.18961976 0.53248567 686.50 -1.16500666e+01 -4.72703097e+00 1.25725445e+01 -2.75613802 0.45690311 686.75 -1.04825467e+01 3.17640030e+00 1.09532326e+01 2.84736936 0.35192036 687.00 -3.69394869e+00 1.06696960e+01 1.12910438e+01 1.90409021 0.40739120 687.25 2.28207706e+00 1.25716082e+01 1.27770579e+01 1.39122542 0.41393743 687.50 9.02589341e+00 1.50295749e+01 1.75315394e+01 1.02997827 0.53079115 687.75 1.53990941e+01 1.04200548e+01 1.85932687e+01 0.59489382 0.50058189 688.00 2.29597411e+01 1.14116374e+01 2.56393288e+01 0.46126730 0.56252513 688.25 3.08455339e+01 8.55812596e+00 3.20107557e+01 0.27064351 0.41378390 688.50 4.09136922e+01 -1.44630418e+01 4.33948129e+01 -0.33979057 0.36771544 688.75 1.04509925e+01 -4.63146107e+01 4.74791155e+01 -1.34886122 0.59469080 689.00 2.72907878e+00 -4.83972100e+01 4.84740942e+01 -1.51446680 0.82004645 689.25 -2.52942864e+00 -3.87244378e+01 3.88069593e+01 -1.63602234 0.84584245 689.50 -6.35301466e+00 -3.58438024e+01 3.64024583e+01 -1.74621620 0.88267369 689.75 -8.55961035e+00 -3.47448542e+01 3.57836809e+01 -1.81234260 0.90828159 690.00 -7.85748795e+00 -3.50050048e+01 3.58760432e+01 -1.79160393 0.90214174 690.25 -7.60635622e+00 -3.39392756e+01 3.47811886e+01 -1.79126981 0.74628635 690.50 -1.15805228e+01 -3.37451261e+01 3.56769119e+01 -1.90137911 0.65977839 690.75 -2.57109947e+01 -1.85134891e+01 3.16828744e+01 -2.51752931 0.64950179 691.00 -2.44446203e+01 -1.15428828e+01 2.70328985e+01 -2.70042689 0.68431621 691.25 -2.08247429e+01 -1.04597893e+01 2.33040148e+01 -2.67612511 0.80282875 691.50 -1.96151346e+01 -1.10725618e+01 2.25245451e+01 -2.62769223 0.86900347 691.75 -1.78403302e+01 -1.19595749e+01 2.14781008e+01 -2.55103241 0.83762936 692.00 -1.82736449e+01 -1.40034622e+01 2.30222295e+01 -2.48772821 0.89248219 692.25 -1.84055143e+01 -1.30618815e+01 2.25693532e+01 -2.52440474 0.90517095 692.50 -1.86081360e+01 -1.22592545e+01 2.22834478e+01 -2.55904796 0.90641196 692.75 -2.03478084e+01 -1.36390158e+01 2.44960417e+01 -2.55108296 0.89253805 693.00 -2.15346685e+01 -1.47351059e+01 2.60933956e+01 -2.54151527 0.88438489 693.25 -2.29992203e+01 -1.65826528e+01 2.83539857e+01 -2.51690518 0.90631129 693.50 -2.28342652e+01 -1.58611030e+01 2.78024866e+01 -2.53448757 0.89268246 693.75 -2.24176777e+01 -1.71370809e+01 2.82175799e+01 -2.48891068 0.84631925 694.00 -2.53764898e+01 -1.78675687e+01 3.10357254e+01 -2.52812078 0.81673562 694.25 -3.68344778e+01 -1.00870381e+01 3.81906676e+01 -2.87429801 0.83619328 694.50 -3.98418598e+01 -5.32277992e+00 4.01958428e+01 -3.00878140 0.82708796 694.75 -3.85429393e+01 3.87422370e+00 3.87371627e+01 3.04141207 0.81772647 695.00 -3.42548082e+01 1.12180423e+01 3.60449214e+01 2.82511200 0.82236104 695.25 -2.60900791e+01 1.55505287e+01 3.03728690e+01 2.60409572 0.90838510 695.50 -2.23324440e+01 1.43158259e+01 2.65269849e+01 2.57154722 0.89900940 695.75 -1.81928348e+01 1.32481921e+01 2.25054178e+01 2.51218405 0.91990321 696.00 -1.58400792e+01 1.09003146e+01 1.92282336e+01 2.53886560 0.92475940 696.25 -1.32433637e+01 8.97334625e+00 1.59971131e+01 2.54607744 0.94729762 696.50 -1.25758492e+01 6.93239522e+00 1.43600170e+01 2.63779280 0.93860967 696.75 -1.27391761e+01 4.47953331e+00 1.35038078e+01 2.80346249 0.94014989 697.00 -1.47737945e+01 3.57694889e+00 1.52006436e+01 2.90404936 0.93479052 697.25 -1.73467812e+01 2.60226032e+00 1.75408830e+01 2.99268900 0.94327323 697.50 -1.86191192e+01 3.74024757e+00 1.89910782e+01 2.94334907 0.94239038 697.75 -1.92333157e+01 5.73134662e+00 2.00690998e+01 2.85198040 0.95155169 698.00 -1.74197352e+01 1.02907355e+01 2.02323111e+01 2.60800124 0.93125869 698.25 -1.50475842e+01 1.35226932e+01 2.02309916e+01 2.40951723 0.94690117 698.50 -1.03911968e+01 1.37556465e+01 1.72393382e+01 2.21775289 0.90059825 698.75 -7.68626263e+00 1.29002668e+01 1.50165081e+01 2.10813810 0.87391831 699.00 -3.97833001e+00 7.92260210e+00 8.86536710e+00 2.03616199 0.67637170 699.25 -2.65966732e+00 4.58457983e+00 5.30020778e+00 2.09647984 0.61932974 699.50 -3.57374110e+00 1.88225758e+00 4.03912355e+00 2.65682088 0.38243008 699.75 -4.95096896e+00 3.80191771e-01 4.96554523e+00 3.06495168 0.47239015 700.00 -6.95089726e+00 -1.89739382e+00 7.20521173e+00 -2.87511371 0.61275352 700.25 -8.47271448e+00 -2.18242738e+00 8.74927882e+00 -2.88948986 0.77310692 700.50 -9.95476619e+00 -2.13490753e+00 1.01811198e+01 -2.93033189 0.79143922 700.75 -1.13512472e+01 -2.31278681e+00 1.15844636e+01 -2.94059646 0.83302994 701.00 -1.39869753e+01 -3.63294430e+00 1.44510817e+01 -2.88747034 0.84995875 701.25 -1.53475048e+01 -3.79778432e+00 1.58104102e+01 -2.89901271 0.86493784 701.50 -1.75242704e+01 -2.06137286e+00 1.76450931e+01 -3.02450113 0.89774213 701.75 -1.87255587e+01 -1.12929494e+00 1.87595803e+01 -3.08135793 0.91160496 702.00 -2.09910257e+01 1.50982808e+00 2.10452546e+01 3.06978900 0.89220505 702.25 -2.18481733e+01 2.89154895e+00 2.20386872e+01 3.01000996 0.90803597 702.50 -2.06139692e+01 4.62605923e+00 2.11266692e+01 2.92083623 0.86454069 702.75 -2.01702784e+01 7.93634699e+00 2.16754638e+01 2.76673048 0.84390870 703.00 -2.05048691e+01 1.16067624e+01 2.35619734e+01 2.62651124 0.91873686 703.25 -1.99331900e+01 1.28535371e+01 2.37180413e+01 2.56885983 0.91389010 703.50 -1.75470184e+01 1.54575205e+01 2.33844562e+01 2.41941952 0.88240224 703.75 -1.41285021e+01 1.63262978e+01 2.15907983e+01 2.28415355 0.84941761 704.00 -6.73290110e+00 1.55204507e+01 1.69179297e+01 1.98010401 0.79598201 704.25 -5.56818602e+00 1.49542461e+01 1.59572608e+01 1.92724007 0.86838147 704.50 -4.40218091e+00 1.29087159e+01 1.36387002e+01 1.89945237 0.80332788 704.75 -3.71110866e+00 1.10270070e+01 1.16347415e+01 1.89543659 0.79246288 705.00 -3.83830884e+00 9.40565198e+00 1.01586861e+01 1.95825335 0.86788501 705.25 -3.67065372e+00 8.58648140e+00 9.33816693e+00 1.97477598 0.83090282 705.50 -4.66017137e+00 7.34777340e+00 8.70097530e+00 2.13600476 0.82991406 705.75 -4.89080768e+00 7.27006392e+00 8.76206763e+00 2.16298655 0.88511916 706.00 -4.87078020e+00 6.81582451e+00 8.37734824e+00 2.19127254 0.93130970 706.25 -5.27933762e+00 6.60699828e+00 8.45717636e+00 2.24495918 0.92564983 706.50 -5.36800388e+00 6.19996511e+00 8.20091660e+00 2.28439872 0.91837714 706.75 -6.08562076e+00 6.15654678e+00 8.65666496e+00 2.35040097 0.93831178 707.00 -6.37848410e+00 5.99917385e+00 8.75643457e+00 2.38682965 0.95829350 707.25 -6.27750207e+00 6.23774011e+00 8.84965728e+00 2.35937156 0.96439406 707.50 -6.00302763e+00 6.16918958e+00 8.60785925e+00 2.34254442 0.96346862 707.75 -5.93084289e+00 6.34009748e+00 8.68168955e+00 2.32285532 0.96166023 708.00 -6.00827425e+00 6.61738725e+00 8.93807437e+00 2.30798782 0.97272067 708.25 -5.72028662e+00 6.36777919e+00 8.55980670e+00 2.30268102 0.97402303 708.50 -5.93463564e+00 6.65835917e+00 8.91928512e+00 2.29878731 0.97992587 708.75 -5.65389093e+00 7.07963024e+00 9.06022334e+00 2.24469150 0.97608080 709.00 -5.06430383e+00 7.06622329e+00 8.69360022e+00 2.19263718 0.98352054 709.25 -4.61935375e+00 6.60832056e+00 8.06277431e+00 2.18086483 0.98157186 709.50 -4.01145092e+00 6.37228308e+00 7.52978951e+00 2.13263615 0.97720835 709.75 -3.60892070e+00 6.03661721e+00 7.03313984e+00 2.10962479 0.97811736 710.00 -3.36803256e+00 5.81102717e+00 6.71652292e+00 2.09607576 0.98245470 710.25 -3.44000551e+00 5.35644202e+00 6.36593348e+00 2.14168170 0.97884363 710.50 -3.41378995e+00 5.07745208e+00 6.11837245e+00 2.16271849 0.98224162 710.75 -3.14735283e+00 4.87718280e+00 5.80454493e+00 2.14387586 0.96497003 711.00 -3.10666724e+00 4.57090187e+00 5.52671016e+00 2.16774166 0.96546822 711.25 -3.08688749e+00 4.25792926e+00 5.25916685e+00 2.19808740 0.97498240 711.50 -3.03956969e+00 4.13144349e+00 5.12911389e+00 2.20509292 0.97680121 711.75 -3.17236750e+00 3.99190353e+00 5.09894199e+00 2.24229747 0.96689876 712.00 -3.15792706e+00 3.97857323e+00 5.07952244e+00 2.24170457 0.97658489 712.25 -2.72068175e+00 3.71815245e+00 4.60725155e+00 2.20250139 0.95610271 712.50 -2.59594455e+00 3.38777194e+00 4.26801205e+00 2.22462853 0.94892391 712.75 -2.32926490e+00 3.22858199e+00 3.98110746e+00 2.19577458 0.94628653 713.00 -2.25084594e+00 3.12175931e+00 3.84859567e+00 2.19548977 0.93296995 713.25 -1.94873518e+00 3.05566353e+00 3.62417555e+00 2.13850838 0.91643621 713.50 -1.80762464e+00 2.92951859e+00 3.44232276e+00 2.12364975 0.90455167 713.75 -1.37337007e+00 2.63555993e+00 2.97192219e+00 2.05117507 0.88723555 714.00 -1.12191235e+00 2.40632273e+00 2.65500968e+00 2.00706912 0.85840320 714.25 -5.26145748e-01 2.18751490e+00 2.24990017e+00 1.80683494 0.76611560 714.50 -2.51577116e-01 1.97091844e+00 1.98690980e+00 1.69775439 0.68793427 714.75 4.79338075e-01 1.14844699e+00 1.24446594e+00 1.17539809 0.38379370 715.00 9.91107726e-01 6.60835835e-01 1.19121725e+00 0.58807060 0.33634716 715.25 1.40226225e+00 -6.33004477e-01 1.53851685e+00 -0.42403136 0.51538536 715.50 1.32225159e+00 -9.60758902e-01 1.63444392e+00 -0.62836154 0.52088707 715.75 1.88499492e+00 -1.81474075e+00 2.61657980e+00 -0.76641147 0.72813927 716.00 1.96951363e+00 -2.17907441e+00 2.93723496e+00 -0.83586902 0.76811884 716.25 1.82684075e+00 -2.41622715e+00 3.02910891e+00 -0.92342070 0.77892851 716.50 2.14060690e+00 -2.65989407e+00 3.41426923e+00 -0.89315271 0.82193764 716.75 2.83475086e+00 -3.05878148e+00 4.17036648e+00 -0.82339283 0.83964860 717.00 3.22648618e+00 -3.49771768e+00 4.75859664e+00 -0.82571291 0.79568210 717.25 4.06702198e+00 -4.33135955e+00 5.94149336e+00 -0.81686260 0.81622776 717.50 3.91677104e+00 -4.28978474e+00 5.80890252e+00 -0.83082004 0.68223364 717.75 4.12962119e+00 -4.03595980e+00 5.77431751e+00 -0.77392840 0.46849195 718.00 4.40722305e+00 -3.45381655e+00 5.59932709e+00 -0.66470514 0.36017452 718.25 4.20880003e+00 -3.18054974e+00 5.27540466e+00 -0.64713302 0.24521217 718.50 4.05953185e+00 -1.90138368e+00 4.48275125e+00 -0.43802916 0.17763512 718.75 1.74919060e+00 -2.18021625e+00 2.79517632e+00 -0.89465365 0.06957512 719.00 -9.88729982e-01 -1.93774959e+00 2.17542190e+00 -2.04260751 0.05399511 719.25 -2.27156224e+00 -1.78753492e+00 2.89054944e+00 -2.47487913 0.13812302 719.50 -1.34656638e-01 -2.92244858e+00 2.92554920e+00 -1.61684041 0.16075792 719.75 6.06923365e-01 -4.09685614e+00 4.14156809e+00 -1.42372234 0.35112260 720.00 7.50689845e-01 -4.28466698e+00 4.34993176e+00 -1.39735294 0.32328879 720.25 1.47653737e+00 -4.44752511e+00 4.68621833e+00 -1.25025455 0.34230851 720.50 3.04287505e+00 -4.90121236e+00 5.76896621e+00 -1.01519313 0.47316529 720.75 4.29788440e+00 -4.81259721e+00 6.45235633e+00 -0.84183494 0.49766776 721.00 6.16062543e+00 -5.61220138e+00 8.33367326e+00 -0.73884793 0.50581708 721.25 6.62753405e+00 -6.55253177e+00 9.31986481e+00 -0.77970764 0.47193078 721.50 7.45685923e+00 -3.55924015e+00 8.26274410e+00 -0.44533213 0.28794546 721.75 7.53775669e+00 -4.55328439e-01 7.55149653e+00 -0.06033305 0.23401813 722.00 5.11178476e+00 2.42455469e+00 5.65763280e+00 0.44288266 0.17910413 722.25 3.57397794e+00 1.43257749e+00 3.85040213e+00 0.38122649 0.10803123 722.50 1.37579008e-01 9.60921243e-01 9.70720155e-01 1.42858869 0.00853459 722.75 -1.10167034e+00 3.82371148e-01 1.16614117e+00 2.80751877 0.02133134 723.00 -1.72402863e+00 2.01478536e-01 1.73576159e+00 3.02525540 0.06011126 723.25 -1.62707768e+00 -2.28965083e-01 1.64310888e+00 -3.00178899 0.04060918 723.50 -4.90848658e-01 -2.14792403e+00 2.20329526e+00 -1.79546086 0.09801130 723.75 1.20083994e-01 -1.97079432e+00 1.97444939e+00 -1.50993979 0.09212959 724.00 1.06619866e+00 -2.38610406e+00 2.61347894e+00 -1.15057619 0.17561014 724.25 1.89905738e+00 -3.40301569e+00 3.89704179e+00 -1.06179271 0.36308857 724.50 2.54415879e+00 -2.86164828e+00 3.82906971e+00 -0.84406197 0.41548848 724.75 2.90629141e+00 -2.52313817e+00 3.84873433e+00 -0.71494526 0.37706745 725.00 3.11215125e+00 -2.87030697e+00 4.23369195e+00 -0.74499459 0.31785770 725.25 3.00752968e+00 -3.06882125e+00 4.29684752e+00 -0.79548472 0.30776118 725.50 3.02387813e+00 -2.41476463e+00 3.86974511e+00 -0.67386561 0.33768667 725.75 2.10080896e+00 -1.33587791e+00 2.48957187e+00 -0.56639016 0.22512602 726.00 1.09191570e+00 -3.26785007e-03 1.09192059e+00 -0.00299276 0.10330293 726.25 5.91883995e-01 4.54696405e-01 7.46374895e-01 0.65505953 0.07439369 726.50 -2.50738055e-01 1.03520168e+00 1.06513478e+00 1.80843159 0.09367047 726.75 -1.32919074e+00 1.84366711e+00 2.27285205e+00 2.19544438 0.29650354 727.00 -1.59236502e+00 1.97429431e+00 2.53642748e+00 2.24951780 0.42837301 727.25 -1.57490120e+00 1.51207154e+00 2.18327143e+00 2.37654484 0.35456622 727.50 -1.10570378e+00 9.43766708e-01 1.45371127e+00 2.43504477 0.19060775 727.75 -1.51984389e+00 7.38728141e-01 1.68986530e+00 2.68916293 0.23594003 728.00 -1.93763192e+00 5.38468736e-01 2.01106093e+00 2.87053194 0.31985207 728.25 -2.00115916e+00 -5.15984754e-02 2.00182426e+00 -3.11581407 0.45964338 728.50 -2.26424996e+00 -1.97235315e-01 2.27282416e+00 -3.05470352 0.68117117 728.75 -2.22855109e+00 -2.68497664e-01 2.24466722e+00 -3.02168976 0.63062171 729.00 -2.15620454e+00 -5.26046885e-01 2.21944663e+00 -2.90229831 0.70436854 729.25 -1.74396651e+00 -8.89545418e-01 1.95773089e+00 -2.66992134 0.60500910 729.50 -1.22090074e+00 -1.01543296e+00 1.58798700e+00 -2.44781433 0.52810310 729.75 -4.70448657e-01 -1.41329719e+00 1.48954050e+00 -1.89213264 0.45656568 730.00 2.82960593e-01 -1.72176060e+00 1.74485709e+00 -1.40790863 0.63448051 730.25 6.95970262e-01 -2.45232645e+00 2.54917234e+00 -1.29426737 0.74206680 730.50 7.64385780e-01 -3.11269822e+00 3.20517953e+00 -1.32999126 0.84683441 730.75 1.24625710e+00 -3.48528938e+00 3.70140498e+00 -1.22738797 0.79139769 731.00 1.57543120e+00 -4.03678411e+00 4.33331390e+00 -1.19870690 0.84645412 731.25 1.82775771e+00 -4.00774070e+00 4.40484776e+00 -1.14291693 0.82917393 731.50 1.74160304e+00 -3.93793394e+00 4.30586865e+00 -1.15439497 0.82601355 731.75 1.39104034e+00 -3.65051212e+00 3.90656268e+00 -1.20672909 0.83092577 732.00 1.38515486e+00 -3.43923703e+00 3.70769542e+00 -1.18792097 0.83348739 732.25 1.17601911e+00 -2.86946773e+00 3.10110722e+00 -1.18183714 0.69367030 732.50 1.51985136e+00 -2.49520042e+00 2.92163880e+00 -1.02370526 0.66907965 732.75 1.51275809e+00 -1.85163884e+00 2.39102560e+00 -0.88578513 0.61334802 733.00 1.59232057e+00 -1.67364715e+00 2.31010381e+00 -0.81029424 0.56421288 733.25 2.79645822e+00 -1.06353959e+00 2.99187149e+00 -0.36342367 0.57595028 733.50 3.11119341e+00 -2.79914545e-01 3.12376001e+00 -0.08972857 0.53515757 733.75 2.59199820e+00 9.91754454e-01 2.77525342e+00 0.36543581 0.39825953 734.00 2.94224987e+00 1.03683678e+00 3.11959369e+00 0.33880765 0.41376385 734.25 3.49003266e+00 8.92956900e-01 3.60245750e+00 0.25048554 0.35180940 734.50 4.66493257e+00 1.57481847e+00 4.92358092e+00 0.32557355 0.52289702 734.75 5.28470429e+00 1.50003937e+00 5.49347045e+00 0.27657103 0.47383486 735.00 4.88861154e+00 7.45853263e-01 4.94518148e+00 0.15140200 0.36298207 735.25 4.92909010e+00 9.41335690e-01 5.01817119e+00 0.18870334 0.28383302 735.50 4.82992362e+00 -8.69656535e-02 4.83070649e+00 -0.01800365 0.21466136 735.75 4.61001416e+00 -8.67536705e-01 4.69093280e+00 -0.18600985 0.30201968 736.00 3.93517524e+00 -1.27641095e+00 4.13700726e+00 -0.31365236 0.27748080 736.25 2.41559503e+00 -2.51888881e+00 3.48997138e+00 -0.80632815 0.25688021 736.50 1.31510014e+00 -2.35179852e+00 2.69452123e+00 -1.06092552 0.16251289 736.75 -1.45060333e+00 -3.18571893e+00 3.50043642e+00 -1.99808681 0.43777826 737.00 -1.72102635e+00 -3.69468899e+00 4.07586291e+00 -2.00672052 0.57244273 737.25 -3.15182516e+00 -5.15410319e+00 6.04142215e+00 -2.11964169 0.69665231 737.50 -4.14678234e+00 -5.40972307e+00 6.81622384e+00 -2.22480081 0.71088551 737.75 -5.20002225e+00 -5.26958849e+00 7.40329618e+00 -2.34955000 0.76926246 738.00 -5.99098417e+00 -5.35337993e+00 8.03433681e+00 -2.41233991 0.80393828 738.25 -6.87544694e+00 -4.95477637e+00 8.47476133e+00 -2.51714304 0.85868885 738.50 -6.00130282e+00 -4.85254856e+00 7.71769804e+00 -2.46164033 0.82922289 738.75 -5.74085005e+00 -4.98482998e+00 7.60301843e+00 -2.42656501 0.83486752 739.00 -5.68366188e+00 -4.44656864e+00 7.21636924e+00 -2.47771177 0.79403084 739.25 -5.42451362e+00 -3.87223415e+00 6.66479897e+00 -2.52163844 0.80347041 739.50 -4.70790692e+00 -4.37864098e+00 6.42937667e+00 -2.39241528 0.86556896 739.75 -4.24842325e+00 -4.39039425e+00 6.10939128e+00 -2.33976189 0.87288681 740.00 -3.44717673e+00 -4.56851200e+00 5.72313981e+00 -2.21720392 0.82642094 740.25 -2.96429350e+00 -4.69573071e+00 5.55310029e+00 -2.13389469 0.82286863 740.50 -2.34680783e+00 -4.64481723e+00 5.20402095e+00 -2.03863750 0.77237048 740.75 -2.07787007e+00 -4.46684684e+00 4.92648604e+00 -2.00619872 0.81098686 741.00 -1.88976248e+00 -4.38735349e+00 4.77703599e+00 -1.97750987 0.82672306 741.25 -1.41107960e+00 -4.31479790e+00 4.53967251e+00 -1.88686555 0.83487920 741.50 -9.08320697e-01 -4.16282910e+00 4.26077371e+00 -1.78562711 0.80633823 741.75 -3.90423493e-01 -4.58085839e+00 4.59746605e+00 -1.65582018 0.81113173 742.00 6.74773544e-01 -5.00903111e+00 5.05427660e+00 -1.43689105 0.77528316 742.25 1.68677585e+00 -5.39994935e+00 5.65726663e+00 -1.26803096 0.75981915 742.50 4.55528818e-01 -4.65780233e+00 4.68002447e+00 -1.47330727 0.37964167 742.75 -2.09868685e+00 -4.90148644e+00 5.33189045e+00 -1.97535192 0.28377285 743.00 -3.73242663e+00 -2.10485093e+00 4.28502112e+00 -2.62811277 0.32743116 743.25 -3.80577811e+00 -1.36184576e+00 4.04209981e+00 -2.79795380 0.43390300 743.50 -3.08881474e+00 -1.13436283e+00 3.29052512e+00 -2.78963500 0.44566348 743.75 -2.63475512e+00 -1.17476051e+00 2.88478713e+00 -2.72217783 0.50401637 744.00 -1.66218397e+00 -6.44351690e-01 1.78270712e+00 -2.77177478 0.48814954 744.25 -1.38454502e+00 -5.02901498e-01 1.47304950e+00 -2.79318493 0.41858042 744.50 -2.04038003e-01 -1.06682876e+00 1.08616533e+00 -1.75977078 0.22326739 744.75 1.51163256e-01 -1.67566984e+00 1.68247430e+00 -1.48082921 0.49807929 745.00 1.49882953e-01 -2.40377898e+00 2.40844728e+00 -1.50852390 0.73850250 745.25 1.44829085e-01 -2.61920170e+00 2.62320281e+00 -1.51555745 0.80010211 745.50 2.69521742e-01 -2.62232934e+00 2.63614361e+00 -1.46837644 0.78588878 745.75 8.50284355e-02 -2.67329964e+00 2.67465153e+00 -1.53900050 0.81930990 746.00 1.09535185e-01 -2.73755527e+00 2.73974576e+00 -1.53080561 0.84513396 746.25 6.86629258e-02 -2.68509562e+00 2.68597340e+00 -1.54523003 0.81505464 746.50 1.08521325e-01 -2.54380599e+00 2.54611975e+00 -1.52816117 0.71504653 746.75 3.94227490e-01 -2.48505342e+00 2.51612913e+00 -1.41346794 0.69592064 747.00 2.44890530e-01 -2.76218807e+00 2.77302260e+00 -1.48236936 0.66919095 747.25 1.00554986e-01 -2.68635787e+00 2.68823919e+00 -1.53338208 0.61610273 747.50 -4.56981089e-01 -2.66842985e+00 2.70727715e+00 -1.74040567 0.57903384 747.75 -1.15072177e+00 -2.31753009e+00 2.58749034e+00 -2.03166358 0.52363821 748.00 -1.41870319e+00 -1.45836433e+00 2.03458725e+00 -2.34241010 0.41282339 748.25 -1.24312593e+00 -6.70645986e-01 1.41249004e+00 -2.64685933 0.20630800 748.50 -1.09941988e+00 7.18860616e-01 1.31357705e+00 2.56251255 0.13925388 748.75 -6.03762037e-01 1.47837431e+00 1.59690926e+00 1.95851955 0.17326343 749.00 6.62264403e-01 2.56123984e+00 2.64547607e+00 1.31776650 0.30354289 749.25 2.47430498e+00 2.94305928e+00 3.84496854e+00 0.87171129 0.39749954 749.50 4.48576437e+00 2.86560689e+00 5.32294889e+00 0.56847735 0.61291967 749.75 5.89564463e+00 2.52516062e-01 5.90104991e+00 0.04280479 0.45128852 750.00 6.14144333e+00 -2.67101710e+00 6.69713809e+00 -0.41024022 0.41607888 750.25 4.22870899e+00 -5.40423937e+00 6.86205384e+00 -0.90683001 0.55008839 750.50 3.36381471e+00 -6.10106605e+00 6.96694025e+00 -1.06691825 0.67474760 750.75 2.31983579e+00 -6.12223557e+00 6.54701508e+00 -1.20859362 0.59539168 751.00 6.23208131e-01 -5.81714829e+00 5.85043610e+00 -1.46407047 0.50399760 751.25 -2.01106046e-01 -5.91654623e+00 5.91996309e+00 -1.60477369 0.51103729 751.50 -1.42528802e+00 -4.85867375e+00 5.06341353e+00 -1.85614035 0.41190422 751.75 -3.01936247e+00 -3.78441085e+00 4.84131338e+00 -2.24422012 0.38224969 752.00 -1.79790534e+00 -3.05747795e+00 3.54691909e+00 -2.10237189 0.24513645 752.25 -8.79282802e-01 -6.38067348e-01 1.08640148e+00 -2.51384678 0.03030436 752.50 -3.02385446e-01 8.07033468e-01 8.61823634e-01 1.92929310 0.02035747 752.75 1.34652521e+00 -1.01952218e-01 1.35037935e+00 -0.07557086 0.07301605 753.00 2.29651875e+00 6.07636582e-01 2.37554638e+00 0.25866287 0.25820604 753.25 4.06503010e+00 -1.15726821e+00 4.22655172e+00 -0.27735124 0.44387504 753.50 4.97576015e+00 -1.61990399e+00 5.23280785e+00 -0.31473750 0.64648784 753.75 5.91876901e+00 -3.70940732e+00 6.98509336e+00 -0.55983478 0.76971323 754.00 5.85226631e+00 -4.70137176e+00 7.50679142e+00 -0.67677547 0.79057341 754.25 6.02621075e+00 -6.18996900e+00 8.63891962e+00 -0.79880239 0.76320565 754.50 6.07316005e+00 -7.92624651e+00 9.98542221e+00 -0.91700202 0.83743820 754.75 5.24063652e+00 -9.88291102e+00 1.11864293e+01 -1.08322498 0.84485359 755.00 4.40298701e+00 -1.07929876e+01 1.16565379e+01 -1.18345632 0.82202760 755.25 2.28146161e+00 -1.24456713e+01 1.26530550e+01 -1.38949558 0.82041019 755.50 8.74694478e-01 -1.30208623e+01 1.30502086e+01 -1.50372072 0.76617487 755.75 -3.00427180e+00 -1.28938839e+01 1.32392557e+01 -1.79971188 0.62557135 756.00 -4.30348998e+00 -1.22231561e+01 1.29586099e+01 -1.90932013 0.58500637 756.25 -5.75215274e+00 -5.55072283e+00 7.99360901e+00 -2.37401372 0.28760956 756.50 -4.48775301e+00 -2.72256281e+00 5.24902613e+00 -2.59628680 0.16623692 756.75 -3.52538796e+00 9.76198120e-01 3.65804907e+00 2.87145609 0.07038153 757.00 -2.05496045e+00 1.17810692e+00 2.36871239e+00 2.62103760 0.03819279 757.25 1.43451045e+00 1.29227854e+00 1.93075220e+00 0.73328444 0.03690986 757.50 3.45054028e+00 6.80171918e-01 3.51693931e+00 0.19462520 0.13043166 757.75 4.80973624e+00 7.07739316e-01 4.86152832e+00 0.14609878 0.34229710 758.00 4.87412421e+00 -3.68456541e-01 4.88803099e+00 -0.07545091 0.49328878 758.25 4.40563991e+00 -1.78435914e+00 4.75327262e+00 -0.38482390 0.61106025 758.50 3.44705575e+00 -2.81462925e+00 4.45020574e+00 -0.68474009 0.65673344 758.75 2.59219905e+00 -3.79266694e+00 4.59388925e+00 -0.97124620 0.81812749 759.00 1.47426191e+00 -4.21569863e+00 4.46604558e+00 -1.23438201 0.84573334 759.25 6.14439079e-01 -4.55627808e+00 4.59752165e+00 -1.43674953 0.89359599 759.50 9.48378048e-02 -4.51741002e+00 4.51840541e+00 -1.54980557 0.89477750 759.75 -4.82923696e-01 -3.95446211e+00 3.98384059e+00 -1.69231582 0.85162503 760.00 -1.36708740e+00 -3.08621178e+00 3.37544532e+00 -1.98778554 0.80634964 760.25 -1.84372132e+00 -2.62576129e+00 3.20841560e+00 -2.18297476 0.83670968 760.50 -1.81771358e+00 -2.05655048e+00 2.74471903e+00 -2.29462537 0.76499097 760.75 -1.93027533e+00 -1.61001113e+00 2.51358284e+00 -2.44641172 0.84608380 761.00 -1.61876600e+00 -1.36090352e+00 2.11481956e+00 -2.44252005 0.81940442 761.25 -1.40040276e+00 -1.21606344e+00 1.85470703e+00 -2.42653181 0.80875737 761.50 -1.30632830e+00 -1.20114748e+00 1.77461232e+00 -2.39811680 0.75191897 761.75 -1.31700568e+00 -1.15468035e+00 1.75151097e+00 -2.42177424 0.71936600 762.00 -1.39068175e+00 -1.01165993e+00 1.71972427e+00 -2.51267644 0.68320191 762.25 -1.51809159e+00 -7.05510306e-01 1.67402117e+00 -2.70655288 0.68063666 762.50 -1.44629451e+00 -5.05216918e-01 1.53199607e+00 -2.80552540 0.66586763 762.75 -1.29179985e+00 -4.17208732e-01 1.35750137e+00 -2.82920062 0.61322391 763.00 -1.05267671e+00 -2.13654025e-01 1.07413980e+00 -2.94135005 0.54444466 763.25 -9.96409136e-01 -1.65828134e-01 1.01011392e+00 -2.97667839 0.54516819 763.50 -7.47309760e-01 -9.18008295e-02 7.52927134e-01 -3.01936328 0.42136934 763.75 -6.97633969e-01 3.55270512e-03 6.97643015e-01 3.13650019 0.44655951 764.00 -3.32630491e-01 9.99007632e-02 3.47308517e-01 2.84982804 0.18822784 764.25 -1.02757526e-01 1.40180438e-01 1.73809276e-01 2.20335280 0.05406087 764.50 2.43968193e-01 1.32982578e-01 2.77857599e-01 0.49905926 0.14511009 764.75 3.22782116e-01 -3.63542008e-02 3.24822909e-01 -0.11215504 0.19393163 765.00 3.79659585e-01 -4.82141071e-01 6.13678591e-01 -0.90375788 0.55783864 765.25 5.12087367e-01 -6.07113284e-01 7.94241784e-01 -0.87010018 0.65333918 765.50 7.58539787e-01 -9.30944882e-01 1.20085011e+00 -0.88709211 0.79792329 765.75 7.62187243e-01 -1.14731866e+00 1.37741406e+00 -0.98441979 0.83671920 766.00 6.12024720e-01 -1.52947448e+00 1.64738169e+00 -1.19015754 0.89912369 766.25 4.49352365e-01 -1.73759075e+00 1.79475323e+00 -1.31773392 0.91002378 766.50 1.48946452e-01 -2.02529560e+00 2.03076520e+00 -1.49738542 0.91227748 766.75 -1.38995443e-01 -2.13309951e+00 2.13762327e+00 -1.63586559 0.87701866 767.00 -9.27660119e-01 -2.06626834e+00 2.26495433e+00 -1.99278033 0.91273820 767.25 -1.32511250e+00 -1.97937269e+00 2.38198224e+00 -2.16073086 0.91853370 767.50 -1.69057328e+00 -1.82943040e+00 2.49095436e+00 -2.31676693 0.92891707 767.75 -1.84431220e+00 -1.56210986e+00 2.41695567e+00 -2.43884995 0.89526904 768.00 -2.45738001e+00 -9.00353845e-01 2.61712697e+00 -2.79039378 0.83765219 768.25 -2.68125708e+00 -3.09609406e-01 2.69907346e+00 -3.02663007 0.80941841 768.50 -2.70220738e+00 6.62746956e-01 2.78229370e+00 2.90107887 0.88334283 768.75 -2.54913248e+00 1.23494513e+00 2.83251935e+00 2.69045656 0.83880045 769.00 -1.84374129e+00 2.06165920e+00 2.76583091e+00 2.30045317 0.81194624 769.25 -1.09964371e+00 2.62892928e+00 2.84964655e+00 1.96696624 0.78029295 769.50 -9.49335409e-02 3.29403648e+00 3.29540418e+00 1.59960817 0.75011302 769.75 9.93075411e-01 3.10153483e+00 3.25664199e+00 1.26092251 0.64321805 770.00 1.71356622e+00 2.83395708e+00 3.31174002e+00 1.02696109 0.52275088 770.25 1.76573428e+00 1.34660010e+00 2.22061915e+00 0.65153477 0.28411796 770.50 2.24074710e+00 -1.34556968e+00 2.61371485e+00 -0.54078741 0.32108540 770.75 1.91030339e+00 -2.60120977e+00 3.22731332e+00 -0.93736046 0.47100968 771.00 1.32998749e+00 -2.96744214e+00 3.25185786e+00 -1.14944592 0.64630793 771.25 5.21307146e-01 -2.63571784e+00 2.68677682e+00 -1.37553086 0.62688519 771.50 1.11675533e-01 -2.24898831e+00 2.25175928e+00 -1.52118118 0.73389382 771.75 -2.37117877e-02 -2.30508417e+00 2.30520612e+00 -1.58108270 0.79579041 772.00 -1.03319927e-01 -2.20385282e+00 2.20627338e+00 -1.61764353 0.81835206 772.25 -4.54156008e-02 -1.80714847e+00 1.80771905e+00 -1.59592212 0.74306125 772.50 4.95559353e-02 -1.62457948e+00 1.62533513e+00 -1.54030193 0.76769237 772.75 2.41302273e-01 -1.61206519e+00 1.63002484e+00 -1.42221428 0.74341136 773.00 5.17976147e-01 -1.75929647e+00 1.83396384e+00 -1.28446449 0.77357667 773.25 1.13237106e-01 -2.32264306e+00 2.32540177e+00 -1.52208134 0.80977972 773.50 -1.26965523e-02 -2.38951682e+00 2.38955055e+00 -1.57610972 0.87358145 773.75 2.82927831e-02 -2.45830230e+00 2.45846510e+00 -1.55928776 0.84632078 774.00 -9.51832887e-02 -2.60635925e+00 2.60809670e+00 -1.60729974 0.85173000 774.25 -6.88034724e-01 -2.73069998e+00 2.81604584e+00 -1.81762145 0.86029471 774.50 -1.00902453e+00 -2.78375276e+00 2.96098124e+00 -1.91853606 0.88612202 774.75 -1.30432046e+00 -2.83334209e+00 3.11914720e+00 -2.00222141 0.86847697 775.00 -1.72130045e+00 -2.73811415e+00 3.23421464e+00 -2.13201213 0.88502457 775.25 -2.24215679e+00 -2.34576863e+00 3.24498036e+00 -2.33361474 0.92687659 775.50 -2.39196228e+00 -2.18397106e+00 3.23901422e+00 -2.40161652 0.93091700 775.75 -3.07613504e+00 -1.52526680e+00 3.43351796e+00 -2.68127962 0.90131255 776.00 -3.43557273e+00 -9.41881411e-01 3.56234481e+00 -2.87401167 0.90744186 776.25 -3.33014585e+00 -1.73231256e-02 3.33019090e+00 -3.13639079 0.92532328 776.50 -3.16629451e+00 3.60857939e-01 3.18679139e+00 3.02811375 0.91879951 776.75 -2.41164134e+00 8.44418742e-01 2.55520194e+00 2.80479066 0.90866870 777.00 -2.15827789e+00 1.04221471e+00 2.39674257e+00 2.69172503 0.89688154 777.25 -1.66206785e+00 1.32354965e+00 2.12467720e+00 2.46909531 0.83339398 777.50 -1.35000599e+00 1.34676988e+00 1.90690988e+00 2.35739448 0.77233249 777.75 -7.51357112e-01 1.22515652e+00 1.43720075e+00 2.12091927 0.66037950 778.00 -4.57426129e-01 1.11843323e+00 1.20835903e+00 1.95902716 0.62838040 778.25 -2.62293640e-01 8.31104848e-01 8.71512032e-01 1.87649956 0.64015604 778.50 -3.18007735e-01 6.78266952e-01 7.49116131e-01 2.00921762 0.62973773 778.75 -3.04801507e-01 6.22497941e-01 6.93114453e-01 2.02612373 0.61705677 779.00 -2.85496483e-01 5.73606759e-01 6.40728457e-01 2.03261957 0.56296700 779.25 -2.67838948e-01 6.34791942e-01 6.88983680e-01 1.97006537 0.54950065 779.50 -5.77601308e-02 6.94812134e-01 6.97208817e-01 1.65373619 0.40410283 779.75 1.68891191e-01 8.71867196e-01 8.88074682e-01 1.37945411 0.55620553 780.00 4.61599295e-01 8.33448719e-01 9.52738514e-01 1.06500783 0.57495493 780.25 9.25053693e-01 6.65758138e-01 1.13971849e+00 0.62382331 0.72935118 780.50 1.02034298e+00 4.49525980e-01 1.11497686e+00 0.41497897 0.68785352 780.75 1.17505025e+00 1.20689424e-01 1.18123200e+00 0.10235110 0.68425226 781.00 8.62814801e-01 -2.93014699e-01 9.11211827e-01 -0.32738281 0.50426533 781.25 4.45070154e-01 -4.89713894e-01 6.61745525e-01 -0.83312025 0.40103116 781.50 3.85000545e-02 -5.54488091e-01 5.55823081e-01 -1.50147407 0.27175959 781.75 -8.20865504e-02 -3.58521772e-01 3.67798944e-01 -1.79587517 0.15179248 782.00 5.46851199e-03 8.25026174e-02 8.26836532e-02 1.50461025 0.00931933 782.25 4.80468941e-02 3.56715450e-01 3.59936683e-01 1.43690961 0.12312234 782.50 3.62210374e-01 4.45480832e-01 5.74151136e-01 0.88813210 0.16801235 782.75 8.09413626e-01 6.06000595e-01 1.01113161e+00 0.64266274 0.38039104 783.00 1.10565588e+00 4.54167091e-01 1.19530024e+00 0.38975379 0.41789828 783.25 1.61802865e+00 -1.35277518e-02 1.61808520e+00 -0.00836044 0.43037023 783.50 1.80216789e+00 -6.33706532e-01 1.91033847e+00 -0.33813125 0.53308485 783.75 1.93541846e+00 -8.65629185e-01 2.12017888e+00 -0.42057039 0.59479788 784.00 2.39075497e+00 -1.75702794e+00 2.96696081e+00 -0.63378373 0.55671108 784.25 1.90663906e+00 -2.65285030e+00 3.26693851e+00 -0.94762113 0.57409540 784.50 5.83205231e-01 -3.38385312e+00 3.43374290e+00 -1.40012360 0.65483699 784.75 2.55497243e-02 -3.52553504e+00 3.52562762e+00 -1.56354940 0.68721292 785.00 -1.13081418e+00 -3.30323149e+00 3.49142936e+00 -1.90062704 0.67207903 785.25 -1.71934712e+00 -3.42613154e+00 3.83334474e+00 -2.03590955 0.77772772 785.50 -2.24336342e+00 -3.16754519e+00 3.88149739e+00 -2.18702716 0.83640028 785.75 -2.83314497e+00 -2.89066352e+00 4.04754815e+00 -2.34614583 0.81588777 786.00 -3.74236047e+00 -2.46973037e+00 4.48384099e+00 -2.55826200 0.86413023 786.25 -3.80240647e+00 -1.80460805e+00 4.20890784e+00 -2.69847375 0.82061691 786.50 -4.38596177e+00 -4.35841104e-01 4.40756374e+00 -3.04254598 0.86127181 786.75 -4.81756131e+00 -1.03105926e-01 4.81866453e+00 -3.12019382 0.89068340 787.00 -4.75086729e+00 1.34847884e+00 4.93853574e+00 2.86502811 0.82888930 787.25 -4.38812203e+00 2.39368977e+00 4.99853635e+00 2.64221631 0.83650949 787.50 -3.43519575e+00 3.26307847e+00 4.73795852e+00 2.38188460 0.82334762 787.75 -2.86475210e+00 3.39720921e+00 4.44385362e+00 2.27136813 0.79636675 788.00 -1.10983121e+00 3.79516238e+00 3.95410961e+00 1.85529666 0.74693164 788.25 -5.14511701e-01 3.81692958e+00 3.85145086e+00 1.70478595 0.80396216 788.50 1.51854036e-02 3.78339082e+00 3.78342130e+00 1.56678265 0.83462278 788.75 3.60142067e-01 3.54304034e+00 3.56129712e+00 1.46949651 0.81240173 789.00 7.02583276e-01 3.21299913e+00 3.28891877e+00 1.35551594 0.84139837 789.25 1.03012217e+00 2.91705220e+00 3.09359745e+00 1.23132864 0.85886537 789.50 1.48996202e+00 2.46129326e+00 2.87714291e+00 1.02644689 0.87899399 789.75 1.46335640e+00 2.10200846e+00 2.56122071e+00 0.96264509 0.82500892 790.00 1.30769669e+00 1.81109109e+00 2.23385800e+00 0.94542507 0.82394070 790.25 1.10624164e+00 1.73667542e+00 2.05908039e+00 1.00362274 0.80431884 790.50 8.13405175e-01 1.78659211e+00 1.96304338e+00 1.14355768 0.74228130 790.75 9.39781716e-01 2.26719719e+00 2.45425605e+00 1.17784206 0.81682738 791.00 1.11203538e+00 2.90346900e+00 3.10914054e+00 1.20502844 0.87337006 791.25 1.70802669e+00 3.43950180e+00 3.84025101e+00 1.10987939 0.84734558 791.50 2.70847844e+00 3.99431881e+00 4.82601681e+00 0.97493191 0.87472770 791.75 3.98510999e+00 3.63229207e+00 5.39209118e+00 0.73911389 0.82498753 792.00 5.27793864e+00 2.97731160e+00 6.05978718e+00 0.51360786 0.85432357 792.25 6.01354067e+00 1.79372199e+00 6.27535736e+00 0.28987854 0.83067214 792.50 7.05053924e+00 7.66293854e-01 7.09205963e+00 0.10826090 0.86697555 792.75 7.11722085e+00 -8.40022192e-01 7.16662193e+00 -0.11748320 0.85538087 793.00 7.07319929e+00 -2.18175531e+00 7.40204056e+00 -0.29919443 0.85808266 793.25 5.76723210e+00 -4.44872535e+00 7.28368885e+00 -0.65704425 0.86996910 793.50 5.32848262e+00 -6.04089201e+00 8.05512901e+00 -0.84797673 0.90571642 793.75 3.69718305e+00 -6.49952467e+00 7.47749848e+00 -1.05360454 0.87647184 794.00 2.38525571e+00 -7.00041627e+00 7.39562524e+00 -1.24240311 0.90831909 794.25 1.48106706e+00 -7.03796188e+00 7.19211144e+00 -1.36338298 0.91810711 794.50 7.51251539e-01 -6.65659416e+00 6.69885249e+00 -1.45841361 0.93664587 794.75 -4.48980421e-01 -6.04084067e+00 6.05750274e+00 -1.64498408 0.91318102 795.00 -1.22069590e+00 -5.77429741e+00 5.90191571e+00 -1.77913057 0.92680432 795.25 -1.86596635e+00 -5.09625562e+00 5.42712186e+00 -1.92178083 0.90415586 795.50 -2.22648412e+00 -4.90166268e+00 5.38363525e+00 -1.99716267 0.88487441 795.75 -3.02556202e+00 -4.26791244e+00 5.23154873e+00 -2.18747657 0.88864277 796.00 -3.35727066e+00 -4.02302355e+00 5.23984588e+00 -2.26623116 0.87698065 796.25 -4.29306810e+00 -3.11670338e+00 5.30511769e+00 -2.51363908 0.88620374 796.50 -4.77561431e+00 -2.78790033e+00 5.52981738e+00 -2.61318622 0.89021010 796.75 -5.32701002e+00 -1.76809973e+00 5.61277226e+00 -2.82112164 0.85971423 797.00 -5.85367534e+00 -9.37917330e-01 5.92833905e+00 -2.98271598 0.85943327 797.25 -5.93297172e+00 9.74598724e-01 6.01248668e+00 2.97877850 0.84957188 797.50 -5.85407871e+00 1.90922457e+00 6.15754626e+00 2.82633382 0.86963801 797.75 -4.91131842e+00 3.54879136e+00 6.05928781e+00 2.51587641 0.85640473 798.00 -4.12651616e+00 4.48194613e+00 6.09228830e+00 2.31492949 0.80649700 798.25 -2.10639498e+00 5.83024247e+00 6.19908276e+00 1.91749141 0.77647655 798.50 -1.39656378e+00 6.06435425e+00 6.22308467e+00 1.79714070 0.74114702 798.75 1.16172494e+00 6.32873244e+00 6.43447427e+00 1.38925378 0.64554256 799.00 2.52580534e+00 6.86065173e+00 7.31082997e+00 1.21803738 0.63539072 799.25 5.88169461e+00 6.76787777e+00 8.96652112e+00 0.85534026 0.74438119 799.50 6.72627205e+00 5.53038304e+00 8.70792009e+00 0.68813545 0.64936609 799.75 8.60408532e+00 2.56448699e+00 8.97813331e+00 0.28967105 0.56550675 800.00 8.37453797e+00 6.77328539e-01 8.40188432e+00 0.08070384 0.41452826 800.25 4.93911286e+00 -2.72428301e+00 5.64061644e+00 -0.50405035 0.18635600 800.50 2.66631632e+00 -4.03986929e+00 4.84043248e+00 -0.98742287 0.19519651 800.75 2.00607691e+00 -4.37736113e+00 4.81514642e+00 -1.14107437 0.33692844 801.00 9.20469187e-01 -5.53602154e+00 5.61202263e+00 -1.40603452 0.50302520 801.25 2.56769245e-01 -6.49509290e+00 6.50016632e+00 -1.53128410 0.65502636 801.50 -9.18797173e-01 -5.65441853e+00 5.72858073e+00 -1.73188033 0.60014073 801.75 -1.81335105e+00 -5.22306293e+00 5.52889034e+00 -1.90495807 0.70142004 802.00 -2.20949181e+00 -5.37689462e+00 5.81316178e+00 -1.96068381 0.76616116 802.25 -2.89229899e+00 -4.71104954e+00 5.52805402e+00 -2.12140240 0.82712615 802.50 -2.97902199e+00 -4.07398011e+00 5.04696799e+00 -2.20217690 0.87379741 802.75 -2.92340384e+00 -3.79199233e+00 4.78805763e+00 -2.22756577 0.87693497 803.00 -2.85201177e+00 -2.96884348e+00 4.11679520e+00 -2.33612596 0.83035593 803.25 -3.01967963e+00 -2.61267632e+00 3.99306181e+00 -2.42833075 0.86587086 803.50 -2.76240490e+00 -2.17064664e+00 3.51320191e+00 -2.47558186 0.79919842 803.75 -2.55240834e+00 -2.04111124e+00 3.26816821e+00 -2.46704654 0.81163888 804.00 -2.77556489e+00 -1.56687424e+00 3.18729593e+00 -2.62766666 0.82867661 804.25 -2.75838161e+00 -1.24344669e+00 3.02569476e+00 -2.71808321 0.81230169 804.50 -2.40345658e+00 -1.06434026e+00 2.62857827e+00 -2.72471116 0.78980513 804.75 -2.17777454e+00 -9.42327002e-01 2.37290584e+00 -2.73321663 0.82958068 805.00 -1.91215298e+00 -7.80071025e-01 2.06514887e+00 -2.75424799 0.82479530 805.25 -1.63140537e+00 -7.61752002e-01 1.80048594e+00 -2.70474933 0.80448290 805.50 -1.31182410e+00 -6.11946292e-01 1.44753609e+00 -2.70511467 0.71739051 805.75 -1.12131013e+00 -5.46466640e-01 1.24738214e+00 -2.68811894 0.63150548 806.00 -9.09127884e-01 -8.08531958e-01 1.21665009e+00 -2.41469335 0.52148720 806.25 -6.50745265e-01 -1.11286518e+00 1.28916186e+00 -2.09992535 0.56606149 806.50 -2.96079180e-01 -1.46955224e+00 1.49908194e+00 -1.76961050 0.64755881 806.75 -1.79115776e-01 -1.82393045e+00 1.83270421e+00 -1.66868564 0.69657093 807.00 -3.06964356e-01 -2.61435386e+00 2.63231328e+00 -1.68767617 0.78563964 807.25 -5.31031285e-01 -3.11260835e+00 3.15758213e+00 -1.73977591 0.80884842 807.50 -1.38820306e+00 -3.65083812e+00 3.90585800e+00 -1.93415504 0.84356872 807.75 -1.84503506e+00 -3.55227511e+00 4.00285059e+00 -2.04983952 0.85262868 808.00 -2.74336247e+00 -3.39432424e+00 4.36434126e+00 -2.25052971 0.85663101 808.25 -3.02571586e+00 -3.38752855e+00 4.54205968e+00 -2.29983775 0.82417523 808.50 -3.11376852e+00 -3.35892258e+00 4.58016542e+00 -2.31833745 0.71910450 808.75 -3.54216212e+00 -3.43352046e+00 4.93315064e+00 -2.37176757 0.72495513 809.00 -4.08720353e+00 -3.50081495e+00 5.38153677e+00 -2.43331943 0.74340694 809.25 -4.68980536e+00 -3.28490836e+00 5.72580974e+00 -2.53057415 0.65888751 809.50 -6.76707932e+00 -2.61711771e+00 7.25552670e+00 -2.77256707 0.64232061 809.75 -7.37736080e+00 -2.62823930e+00 7.83154481e+00 -2.79935423 0.67171030 810.00 -7.77332290e+00 -2.54248447e-01 7.77747975e+00 -3.10889649 0.69540135 810.25 -7.57312794e+00 2.06754290e+00 7.85028665e+00 2.87507707 0.64981358 810.50 -6.30928712e+00 3.21120125e+00 7.07947154e+00 2.67079943 0.65923695 810.75 -5.13082650e+00 4.31758424e+00 6.70573741e+00 2.44205474 0.62233283 811.00 -3.16165923e+00 5.56827024e+00 6.40325875e+00 2.08720215 0.47745505 811.25 -2.73969759e+00 4.71845176e+00 5.45616440e+00 2.09685504 0.42156765 811.50 -8.24774754e-01 5.47999794e+00 5.54171731e+00 1.72018149 0.47421896 811.75 -2.35937776e-01 4.92490189e+00 4.93055020e+00 1.61866683 0.47339027 812.00 1.11472458e+00 3.62898905e+00 3.79633671e+00 1.27277258 0.41624876 812.25 2.28502047e+00 3.19372409e+00 3.92698257e+00 0.94976170 0.47603901 812.50 2.56071568e+00 3.46529506e+00 4.30877415e+00 0.93439811 0.42024357 812.75 3.15540445e+00 2.02108367e+00 3.74717980e+00 0.56967841 0.36150771 813.00 2.66910230e+00 1.43560228e+00 3.03068655e+00 0.49347461 0.28162012 813.25 2.59343096e+00 1.06443336e+00 2.80337342e+00 0.38946909 0.26752375 813.50 2.01522308e+00 4.64805610e-01 2.06813160e+00 0.22668301 0.14835084 813.75 1.04143714e+00 9.12115118e-01 1.38439348e+00 0.71929621 0.09784683 814.00 1.24969949e+00 7.78459305e-01 1.47232731e+00 0.55710017 0.12322398 814.25 1.25356561e+00 -4.03978342e-01 1.31705172e+00 -0.31175477 0.10968158 814.50 7.21739130e-01 -1.98905981e+00 2.11595517e+00 -1.22271612 0.25953909 814.75 1.39765717e+00 -1.12559563e+00 1.79455038e+00 -0.67799135 0.29402409 815.00 1.46241633e+00 -9.88854896e-01 1.76535989e+00 -0.59455904 0.25186471 815.25 9.44200647e-01 -1.91352869e+00 2.13380105e+00 -1.11241508 0.28940387 815.50 4.44327347e-01 -1.96577317e+00 2.01536373e+00 -1.34849997 0.26515992 815.75 -8.82475746e-01 -1.47127497e+00 1.71563792e+00 -2.11107126 0.14157725 816.00 -1.55029665e+00 -9.40377258e-01 1.81320961e+00 -2.59634975 0.14057316 816.25 -1.53118821e+00 -1.18481755e+00 1.93606042e+00 -2.48303922 0.25878753 816.50 -1.34663413e+00 -1.06388776e+00 1.71618199e+00 -2.47295769 0.25291645 816.75 -1.30258487e+00 -1.13922657e+00 1.73048101e+00 -2.42299540 0.17854014 817.00 -1.73840737e+00 -1.50193001e+00 2.29735803e+00 -2.42904458 0.22919481 817.25 -3.20066146e+00 -1.05106870e+00 3.36882460e+00 -2.82429669 0.26184073 817.50 -4.46074000e+00 -6.62518773e-01 4.50967100e+00 -2.99414833 0.41779752 817.75 -4.68345671e+00 7.41119980e-01 4.74173234e+00 2.98465189 0.61060230 818.00 -4.55475649e+00 1.16131572e+00 4.70047454e+00 2.89194401 0.58475480 818.25 -3.63301731e+00 2.82013110e+00 4.59912537e+00 2.48150187 0.51200308 818.50 -2.90320862e+00 3.80593793e+00 4.78683442e+00 2.22244574 0.59983085 818.75 -2.16642930e+00 3.80999506e+00 4.38286188e+00 2.08782065 0.58083025 819.00 -2.35620228e+00 3.35048053e+00 4.09602356e+00 2.18369555 0.62534074 819.25 -1.81174602e+00 3.21476260e+00 3.69013851e+00 2.08399877 0.65840190 819.50 -1.94824942e+00 3.16329781e+00 3.71512164e+00 2.12281915 0.69590841 819.75 -2.57294601e+00 3.13410508e+00 4.05495571e+00 2.25818222 0.78088185 820.00 -2.45051700e+00 3.07863874e+00 3.93485070e+00 2.24307769 0.76674547 820.25 -1.87611963e+00 3.66112369e+00 4.11383660e+00 2.04434924 0.78111379 820.50 -1.40650516e+00 3.86555818e+00 4.11348961e+00 1.91976099 0.84338099 820.75 -1.03482983e+00 4.42337784e+00 4.54281238e+00 1.80060884 0.92139596 821.00 -3.21448992e-01 4.67085119e+00 4.68189922e+00 1.63950820 0.92253583 821.25 6.00743471e-01 4.21027181e+00 4.25291446e+00 1.42906778 0.92912841 821.50 9.51170995e-01 3.84629371e+00 3.96215870e+00 1.32836472 0.93276776 821.75 1.27085773e+00 3.44933829e+00 3.67600517e+00 1.21779346 0.92634544 822.00 1.41996962e+00 3.28225692e+00 3.57624443e+00 1.16248931 0.91133173 822.25 1.46492477e+00 3.03878387e+00 3.37345698e+00 1.12159046 0.87961043 822.50 1.55156250e+00 2.97709908e+00 3.35715134e+00 1.09035974 0.88633685 822.75 1.82585652e+00 2.93589114e+00 3.45734129e+00 1.01442299 0.90118117 823.00 1.86909588e+00 2.57682549e+00 3.18332358e+00 0.94325990 0.87807352 823.25 1.98213534e+00 2.29439191e+00 3.03201166e+00 0.85828521 0.87887884 823.50 2.14699346e+00 1.86500853e+00 2.84391239e+00 0.71522822 0.88400577 823.75 2.10459152e+00 1.69811909e+00 2.70423999e+00 0.67891231 0.89988102 824.00 1.85506021e+00 1.63978319e+00 2.47591141e+00 0.72387742 0.85135556 824.25 1.87350829e+00 1.53418330e+00 2.42151848e+00 0.68614913 0.89688927 824.50 2.00558085e+00 1.44792492e+00 2.47362914e+00 0.62530475 0.90460070 824.75 1.98896333e+00 1.42654416e+00 2.44765263e+00 0.62219636 0.89844137 825.00 2.07487902e+00 1.52106681e+00 2.57269648e+00 0.63258862 0.91681405 825.25 2.21519975e+00 1.62185663e+00 2.74545604e+00 0.63197834 0.92693039 825.50 2.45968026e+00 1.76267408e+00 3.02606128e+00 0.62179830 0.92169380 825.75 2.62501214e+00 1.81408028e+00 3.19085819e+00 0.60471088 0.92286827 826.00 3.21281247e+00 1.68643828e+00 3.62853112e+00 0.48337666 0.91589492 826.25 3.38472576e+00 1.51902237e+00 3.70995923e+00 0.42184509 0.91419875 826.50 3.42454493e+00 9.80705468e-01 3.56220313e+00 0.27891078 0.85306816 826.75 3.61279060e+00 7.30683371e-01 3.68594005e+00 0.19955714 0.88609418 827.00 3.95780054e+00 3.79561505e-01 3.97595926e+00 0.09560973 0.90479302 827.25 4.15609382e+00 1.84797991e-01 4.16020026e+00 0.04443508 0.91098800 827.50 4.65548326e+00 -4.69906680e-01 4.67913846e+00 -0.10059547 0.91704927 827.75 4.87116860e+00 -5.91435671e-01 4.90694199e+00 -0.12082416 0.90291563 828.00 5.55336819e+00 -1.42352387e+00 5.73291536e+00 -0.25093228 0.89860960 828.25 5.84969548e+00 -1.75957525e+00 6.10860395e+00 -0.29218852 0.92967983 828.50 5.82602090e+00 -2.79211277e+00 6.46052732e+00 -0.44690916 0.88728540 828.75 6.04817666e+00 -3.69153411e+00 7.08575084e+00 -0.54799861 0.87998291 829.00 6.05874135e+00 -5.23029273e+00 8.00401829e+00 -0.71214422 0.90743100 829.25 5.72150793e+00 -6.01930487e+00 8.30467845e+00 -0.81075698 0.88965705 829.50 4.03743328e+00 -8.17407483e+00 9.11681780e+00 -1.11201527 0.88062115 829.75 2.60799092e+00 -8.42443831e+00 8.81888754e+00 -1.27057894 0.86891977 830.00 4.30799758e-01 -8.15414478e+00 8.16551686e+00 -1.51801340 0.86268087 830.25 -7.77580355e-01 -8.06695461e+00 8.10434377e+00 -1.66689027 0.87038847 830.50 -2.06839357e+00 -7.42670878e+00 7.70936153e+00 -1.84242043 0.84114280 830.75 -2.65749550e+00 -6.77938115e+00 7.28164069e+00 -1.94438438 0.79048948 831.00 -4.51577310e+00 -5.74149085e+00 7.30458239e+00 -2.23726093 0.84535095 831.25 -4.90521813e+00 -4.72733304e+00 6.81240358e+00 -2.37465947 0.84897315 831.50 -4.42776374e+00 -3.39389439e+00 5.57885390e+00 -2.48761299 0.80614551 831.75 -3.89727184e+00 -3.16467392e+00 5.02034748e+00 -2.45956356 0.80094067 832.00 -4.01782774e+00 -2.59470812e+00 4.78282866e+00 -2.56817654 0.82539432 832.25 -3.51956756e+00 -2.12302247e+00 4.11030172e+00 -2.59881951 0.81108219 832.50 -3.31041524e+00 -1.70836543e+00 3.72523308e+00 -2.66518152 0.79116285 832.75 -3.44416419e+00 -1.82705599e+00 3.89876911e+00 -2.65386037 0.78896378 833.00 -2.98842240e+00 -1.64032631e+00 3.40900848e+00 -2.63959918 0.76942569 833.25 -2.63847311e+00 -1.44563628e+00 3.00855523e+00 -2.64035824 0.71498061 833.50 -2.39665906e+00 -1.64487478e+00 2.90681745e+00 -2.54010710 0.77101816 833.75 -2.42595143e+00 -2.05647589e+00 3.18030398e+00 -2.43843613 0.77559414 834.00 -2.46871038e+00 -2.56253931e+00 3.55824938e+00 -2.33754742 0.81628000 834.25 -2.95939498e+00 -2.83024249e+00 4.09491040e+00 -2.37849832 0.88902492 834.50 -3.34148268e+00 -2.60990337e+00 4.23994128e+00 -2.47850675 0.90579799 834.75 -3.90140826e+00 -2.51815648e+00 4.64350067e+00 -2.56842403 0.93220582 835.00 -4.21782886e+00 -2.46471287e+00 4.88517040e+00 -2.61275565 0.94965190 835.25 -4.85287304e+00 -1.89587357e+00 5.21005886e+00 -2.76915487 0.93886315 835.50 -4.98449804e+00 -1.68537541e+00 5.26172129e+00 -2.81553725 0.94761105 835.75 -5.17616198e+00 -1.30338404e+00 5.33773949e+00 -2.89491579 0.94601467 836.00 -5.29734883e+00 -1.03618129e+00 5.39773808e+00 -2.94842781 0.96063527 836.25 -5.16403157e+00 -1.83926594e-01 5.16730598e+00 -3.10599084 0.94285748 836.50 -5.18232156e+00 2.51108336e-01 5.18840170e+00 3.09317573 0.94089553 836.75 -5.08893693e+00 9.91895422e-01 5.18470207e+00 2.94909405 0.94739268 837.00 -4.96090533e+00 1.31675945e+00 5.13268323e+00 2.88214775 0.95546852 837.25 -4.19205085e+00 1.96598938e+00 4.63016248e+00 2.70306728 0.91991412 837.50 -3.69712355e+00 2.02874261e+00 4.21716957e+00 2.63972085 0.91533162 837.75 -3.42139899e+00 2.00519618e+00 3.96570079e+00 2.61147510 0.91775263 838.00 -3.23912387e+00 1.92483653e+00 3.76787993e+00 2.60541475 0.91888594 838.25 -2.91274402e+00 1.67293622e+00 3.35898695e+00 2.62024657 0.91762051 838.50 -2.79951241e+00 1.52370770e+00 3.18731154e+00 2.64315461 0.91557217 838.75 -2.54135243e+00 1.48082689e+00 2.94131271e+00 2.61399650 0.84245166 839.00 -2.53369692e+00 1.61300892e+00 3.00356752e+00 2.57467908 0.86679664 839.25 -2.70287033e+00 1.52656219e+00 3.10417463e+00 2.62746305 0.89887153 839.50 -2.67497665e+00 1.65902068e+00 3.14767370e+00 2.58645243 0.88749421 839.75 -2.52389458e+00 1.91468936e+00 3.16797715e+00 2.49259440 0.89984425 840.00 -2.35770877e+00 1.99181340e+00 3.08643990e+00 2.44012001 0.86950281 840.25 -1.84199472e+00 1.99460310e+00 2.71502966e+00 2.31643844 0.79658209 840.50 -1.48144550e+00 1.80191997e+00 2.33272295e+00 2.25889721 0.75656668 840.75 -1.32270041e+00 1.24645555e+00 1.81746742e+00 2.38586279 0.69725482 841.00 -1.22855683e+00 1.11585763e+00 1.65966567e+00 2.40422887 0.62166046 841.25 -1.57732590e+00 8.00121842e-01 1.76865823e+00 2.67215014 0.69523808 841.50 -1.74990150e+00 6.33706727e-01 1.86111243e+00 2.79414521 0.68215328 841.75 -2.32333254e+00 4.05351766e-01 2.35842832e+00 2.96886131 0.69875192 842.00 -3.28933071e+00 7.09151797e-01 3.36490606e+00 2.92925118 0.80267432 842.25 -3.97550401e+00 1.07699044e+00 4.11880329e+00 2.87703597 0.90685278 842.50 -4.04008655e+00 1.49890544e+00 4.30917821e+00 2.78632619 0.89991332 842.75 -4.03459940e+00 2.32498276e+00 4.65655851e+00 2.61881113 0.87518873 843.00 -4.07014667e+00 3.08557651e+00 5.10753134e+00 2.49292793 0.87708106 843.25 -3.66095947e+00 4.29870240e+00 5.64636756e+00 2.27624342 0.88794941 843.50 -2.93346850e+00 4.87172850e+00 5.68673686e+00 2.11278876 0.88234055 843.75 -2.46637131e+00 5.54813319e+00 6.07163646e+00 1.98910108 0.86901144 844.00 -1.19271913e+00 5.72601648e+00 5.84891816e+00 1.77615808 0.84811546 844.25 -2.48764841e-01 5.73873723e+00 5.74412647e+00 1.61411756 0.90761298 844.50 4.81684472e-01 5.44002655e+00 5.46131017e+00 1.48248214 0.88006546 844.75 1.22210758e+00 4.94185569e+00 5.09072535e+00 1.32836299 0.89323014 845.00 1.73677281e+00 4.66558886e+00 4.97836311e+00 1.21443741 0.91156894 845.25 1.91189829e+00 4.32394528e+00 4.72777515e+00 1.15447686 0.90019601 845.50 2.00150071e+00 3.72541671e+00 4.22903473e+00 1.07779036 0.87656978 845.75 2.05618427e+00 3.57544333e+00 4.12452285e+00 1.04889808 0.88894862 846.00 2.08777068e+00 3.00790598e+00 3.66145938e+00 0.96404486 0.79824575 846.25 2.47581295e+00 2.67812634e+00 3.64719213e+00 0.82463215 0.79614716 846.50 2.40467431e+00 2.50490209e+00 3.47231810e+00 0.80581008 0.82015083 846.75 2.31057217e+00 2.47340835e+00 3.38474410e+00 0.81942283 0.79393508 847.00 2.05003230e+00 1.82515107e+00 2.74477848e+00 0.72743205 0.77774206 847.25 1.96636053e+00 1.59693980e+00 2.53313846e+00 0.68209347 0.76141040 847.50 2.55189822e+00 1.20643903e+00 2.82270786e+00 0.44162027 0.77690431 847.75 2.87064650e+00 1.20459120e+00 3.11314171e+00 0.39730804 0.84423492 848.00 2.72933591e+00 6.88283346e-01 2.81478392e+00 0.24702917 0.80593650 848.25 2.32032390e+00 3.24833392e-01 2.34295107e+00 0.13909089 0.76444831 848.50 2.35495179e+00 3.60682088e-02 2.35522798e+00 0.01531470 0.71840746 848.75 2.31276441e+00 -4.90363707e-02 2.31328419e+00 -0.02119932 0.73784750 849.00 1.85706806e+00 -3.20779514e-01 1.88456926e+00 -0.17104653 0.65455389 849.25 1.78780331e+00 -4.44752018e-01 1.84229342e+00 -0.24382078 0.63190345 849.50 1.70404579e+00 -7.71005094e-01 1.87035315e+00 -0.42489414 0.62461505 849.75 1.44946009e+00 -9.23800984e-01 1.71882018e+00 -0.56742488 0.54936061 850.00 9.64008662e-01 -7.69013939e-01 1.23316468e+00 -0.67335229 0.56384852 850.25 8.66594527e-01 -7.69550674e-01 1.15896260e+00 -0.72615508 0.54872667 850.50 7.73256357e-01 -5.89094948e-01 9.72089632e-01 -0.65103356 0.44913509 850.75 6.45042266e-01 -5.07912165e-01 8.21008095e-01 -0.66701629 0.40069430 851.00 6.49007657e-01 -3.80668636e-01 7.52409164e-01 -0.53046329 0.33807836 851.25 7.69381873e-01 -3.43560132e-01 8.42604315e-01 -0.41997324 0.38804623 851.50 9.20122099e-01 -1.62433857e-01 9.34349739e-01 -0.17473477 0.47720198 851.75 1.05316908e+00 -1.06486178e-01 1.05853882e+00 -0.10076778 0.54777834 852.00 1.04248110e+00 -3.20872397e-01 1.09074559e+00 -0.29859443 0.58922753 852.25 1.03768304e+00 -4.20217070e-01 1.11953940e+00 -0.38477239 0.56254758 852.50 1.18309694e+00 -5.11006785e-01 1.28873826e+00 -0.40771985 0.60934295 852.75 1.37661733e+00 -6.47220977e-01 1.52117397e+00 -0.43948632 0.69944225 853.00 1.50829460e+00 -9.44132326e-01 1.77942082e+00 -0.55928947 0.76413342 853.25 1.71264176e+00 -9.83280739e-01 1.97483742e+00 -0.52118096 0.80314966 853.50 1.70201281e+00 -1.18575349e+00 2.07433338e+00 -0.60849240 0.78019259 853.75 1.63512673e+00 -1.51331945e+00 2.22795314e+00 -0.74672939 0.73187562 854.00 1.47202995e+00 -1.83977465e+00 2.35619247e+00 -0.89598571 0.76201295 854.25 1.18486028e+00 -2.23420891e+00 2.52894906e+00 -1.08318285 0.77815387 854.50 1.01897519e+00 -2.61623327e+00 2.80766575e+00 -1.19939014 0.85278791 854.75 7.70132954e-01 -2.77230154e+00 2.87728355e+00 -1.29983300 0.80941432 855.00 4.38155803e-01 -2.91816153e+00 2.95087228e+00 -1.42176174 0.86481701 855.25 1.19465247e-01 -2.87244735e+00 2.87493056e+00 -1.52923023 0.77034277 855.50 -4.36539391e-01 -2.86246289e+00 2.89555874e+00 -1.72213507 0.81070248 855.75 -5.54316503e-01 -2.32568058e+00 2.39082767e+00 -1.80477674 0.76087696 856.00 -6.63944772e-01 -2.15539049e+00 2.25533387e+00 -1.86961212 0.75124538 856.25 -8.40585211e-01 -2.46410585e+00 2.60353627e+00 -1.89954913 0.77094199 856.50 -1.09672400e+00 -2.56266300e+00 2.78748008e+00 -1.97517367 0.77652366 856.75 -1.81742118e+00 -2.37132753e+00 2.98767702e+00 -2.22472058 0.78510408 857.00 -2.04813115e+00 -2.27423521e+00 3.06055338e+00 -2.30393188 0.80260363 857.25 -2.22668822e+00 -2.12496339e+00 3.07792297e+00 -2.37956638 0.81145208 857.50 -2.35504324e+00 -2.03232814e+00 3.11072119e+00 -2.42961772 0.83711097 857.75 -2.41328232e+00 -1.74914035e+00 2.98050726e+00 -2.51441738 0.86992043 858.00 -2.34046136e+00 -1.65921285e+00 2.86892779e+00 -2.52490147 0.86172870 858.25 -2.41469280e+00 -1.33214955e+00 2.75778239e+00 -2.63745678 0.84896365 858.50 -2.33778168e+00 -1.11805326e+00 2.59138308e+00 -2.69549276 0.85277329 858.75 -2.03542710e+00 -1.00336720e+00 2.26929708e+00 -2.68359959 0.80919658 859.00 -1.95251354e+00 -1.07483952e+00 2.22880890e+00 -2.63837319 0.80072136 859.25 -2.03644705e+00 -1.12113118e+00 2.32466163e+00 -2.63834037 0.87042269 859.50 -2.11970785e+00 -1.09692423e+00 2.38671409e+00 -2.66405241 0.88441416 859.75 -2.28933218e+00 -1.05554919e+00 2.52095734e+00 -2.70956869 0.89665445 860.00 -2.30439378e+00 -8.95606322e-01 2.47231498e+00 -2.77090750 0.87175032 860.25 -2.39481346e+00 -6.46978753e-01 2.48066786e+00 -2.87773327 0.92911680 860.50 -2.35614953e+00 -6.31525236e-01 2.43931644e+00 -2.87971531 0.93238319 860.75 -2.07291286e+00 -5.07153013e-01 2.13405059e+00 -2.90164881 0.84043782 861.00 -1.90562247e+00 -5.23010192e-01 1.97609126e+00 -2.87373194 0.82374591 861.25 -1.75886870e+00 -7.42864263e-01 1.90931046e+00 -2.74196579 0.83407436 861.50 -1.75871784e+00 -9.28802658e-01 1.98890996e+00 -2.65570801 0.83416177 861.75 -1.82484760e+00 -1.24871302e+00 2.21118814e+00 -2.54149277 0.81739066 862.00 -2.22250224e+00 -1.46915315e+00 2.66419353e+00 -2.55749860 0.83724801 862.25 -2.81310076e+00 -1.62904111e+00 3.25074004e+00 -2.61668937 0.92536575 862.50 -2.94067785e+00 -1.47215325e+00 3.28858958e+00 -2.67745159 0.93742825 862.75 -3.24488754e+00 -1.10859315e+00 3.42903396e+00 -2.81238212 0.92948362 863.00 -3.49028426e+00 -8.24373895e-01 3.58631796e+00 -2.90965228 0.94364906 863.25 -3.58522533e+00 -6.06321088e-01 3.63613337e+00 -2.97406122 0.94180003 863.50 -3.72118308e+00 -4.64849913e-01 3.75010520e+00 -3.01731650 0.93842704 863.75 -3.67864680e+00 -1.55934804e-01 3.68195029e+00 -3.09922884 0.96537636 864.00 -3.58363132e+00 3.03635585e-02 3.58375995e+00 3.13312001 0.96203506 864.25 -3.54247802e+00 3.06678788e-01 3.55572811e+00 3.05523614 0.96163179 864.50 -3.42936739e+00 4.22915470e-01 3.45534632e+00 3.01889046 0.96091657 864.75 -3.39765989e+00 4.94761550e-01 3.43349409e+00 2.99699069 0.96321244 865.00 -3.20731943e+00 5.65592595e-01 3.25680717e+00 2.96704290 0.95531896 865.25 -3.12180361e+00 6.55244320e-01 3.18982804e+00 2.93470307 0.95470210 865.50 -3.03965121e+00 5.01775522e-01 3.08078856e+00 2.97799139 0.94167369 865.75 -3.01308400e+00 4.67966312e-01 3.04920771e+00 2.98751227 0.93509658 866.00 -2.87260840e+00 4.33002017e-01 2.90505934e+00 2.99198416 0.94236736 866.25 -2.86154575e+00 4.03030624e-01 2.88978853e+00 3.00166935 0.96379098 866.50 -2.94855866e+00 5.48868590e-01 2.99920904e+00 2.95755101 0.94518866 866.75 -2.97208715e+00 6.80903261e-01 3.04908696e+00 2.91637982 0.92286653 867.00 -2.95847090e+00 6.52254665e-01 3.02951914e+00 2.92459390 0.88955089 867.25 -2.99464158e+00 8.78941109e-01 3.12096390e+00 2.85610553 0.91282322 867.50 -2.97172505e+00 8.92640945e-01 3.10289504e+00 2.84978907 0.92612223 867.75 -2.90358627e+00 8.06196095e-01 3.01343083e+00 2.87075952 0.93679662 868.00 -2.73410655e+00 8.08786778e-01 2.85122336e+00 2.85398071 0.93125327 868.25 -2.58387892e+00 8.42001340e-01 2.71760860e+00 2.82657662 0.90286984 868.50 -2.45497173e+00 8.13179238e-01 2.58614513e+00 2.82172934 0.89938366 868.75 -2.48315311e+00 7.34510639e-01 2.58950869e+00 2.85399575 0.90853958 869.00 -2.57557716e+00 6.52291514e-01 2.65689328e+00 2.89354781 0.89345357 869.25 -2.68131555e+00 6.79957488e-01 2.76618786e+00 2.89323709 0.93375989 869.50 -2.70397125e+00 7.71893709e-01 2.81198869e+00 2.86352192 0.92083007 869.75 -2.57878978e+00 8.72579306e-01 2.72241646e+00 2.81531798 0.90615092 870.00 -2.38365423e+00 8.60461105e-01 2.53420615e+00 2.79516622 0.89200487 870.25 -2.28166066e+00 8.18274935e-01 2.42395322e+00 2.79724927 0.87520608 870.50 -2.26347867e+00 4.56638910e-01 2.30908094e+00 2.94252257 0.81478018 870.75 -2.17273210e+00 2.48627869e-01 2.18691120e+00 3.02765725 0.74460603 871.00 -2.05215946e+00 -1.29772472e-01 2.05625858e+00 -3.07843971 0.78593626 871.25 -2.09851991e+00 -3.00445818e-01 2.11991828e+00 -2.99938867 0.77129907 871.50 -2.30590823e+00 -8.42748013e-01 2.45508390e+00 -2.79120016 0.78888016 871.75 -2.33948113e+00 -9.96649723e-01 2.54292796e+00 -2.73886417 0.80246691 872.00 -2.83730357e+00 -1.32231776e+00 3.13030602e+00 -2.70547419 0.81694575 872.25 -3.14514068e+00 -1.57952830e+00 3.51949137e+00 -2.67617678 0.82592749 872.50 -3.75571556e+00 -1.85442372e+00 4.18859006e+00 -2.68294915 0.86873752 872.75 -3.93984321e+00 -1.91770160e+00 4.38177407e+00 -2.68860463 0.85502951 873.00 -4.48640452e+00 -1.82353465e+00 4.84284050e+00 -2.75553153 0.80714576 873.25 -5.41981470e+00 -2.03517540e+00 5.78932900e+00 -2.78237804 0.84026082 873.50 -6.62869369e+00 -2.13226479e+00 6.96319849e+00 -2.83037380 0.87791087 873.75 -6.87909185e+00 -1.81776648e+00 7.11520764e+00 -2.88325240 0.87575040 874.00 -7.64441487e+00 -3.30089235e-01 7.65153825e+00 -3.09843902 0.88473490 874.25 -8.70607423e+00 6.29683647e-01 8.72881607e+00 3.06939144 0.88084857 874.50 -9.18294846e+00 6.87134116e-01 9.20862072e+00 3.06690466 0.87967285 874.75 -9.21224031e+00 1.53055713e+00 9.33852112e+00 2.97695270 0.86136159 875.00 -9.11287951e+00 2.90996586e+00 9.56621526e+00 2.83250257 0.90818690 875.25 -9.07292682e+00 3.62227842e+00 9.76928360e+00 2.76174132 0.92463548 875.50 -9.36355901e+00 3.77706630e+00 1.00966562e+01 2.75817645 0.92099359 875.75 -8.49163972e+00 3.51242854e+00 9.18940147e+00 2.74938860 0.91319596 876.00 -8.12606676e+00 3.65365319e+00 8.90966569e+00 2.71905365 0.92207565 876.25 -8.01458614e+00 4.00647031e+00 8.96021179e+00 2.67802717 0.91083543 876.50 -8.27575935e+00 4.40196556e+00 9.37365956e+00 2.65274351 0.90138636 876.75 -7.89219467e+00 5.31108967e+00 9.51285500e+00 2.54924941 0.88216853 877.00 -7.56844466e+00 5.79428820e+00 9.53179576e+00 2.48819149 0.88070471 877.25 -7.51481945e+00 5.55472964e+00 9.34492015e+00 2.50505880 0.86613888 877.50 -7.14448303e+00 5.11415103e+00 8.78624940e+00 2.52032914 0.83367079 877.75 -6.46331320e+00 6.05634474e+00 8.85741097e+00 2.38868940 0.75821990 878.00 -6.69678418e+00 6.92185742e+00 9.63114887e+00 2.33966915 0.77996453 878.25 -6.66832716e+00 6.14961725e+00 9.07107378e+00 2.39663990 0.64026255 878.50 -7.36089356e+00 5.48287258e+00 9.17848820e+00 2.50138600 0.59758376 878.75 -6.07656834e+00 6.31328177e+00 8.76254583e+00 2.33709138 0.51674264 879.00 -5.53910133e+00 5.71986333e+00 7.96231625e+00 2.34014093 0.43934342 879.25 -5.43803644e+00 3.71171206e+00 6.58399930e+00 2.54267683 0.23294951 879.50 -3.78939852e+00 2.48726785e+00 4.53277426e+00 2.56074867 0.12089863 879.75 -2.88724152e+00 1.09857658e+00 3.08918017e+00 2.77801450 0.05396796 880.00 -4.01261510e+00 1.03940208e-01 4.01396108e+00 3.11569509 0.08983770 880.25 -4.51303019e+00 -2.34276784e+00 5.08487981e+00 -2.66277266 0.20401594 880.50 -2.92618405e+00 -3.68903596e+00 4.70866641e+00 -2.24138393 0.22350648 880.75 -1.77418136e+00 -3.42381380e+00 3.85619248e+00 -2.04888873 0.27639323 881.00 -3.14588488e+00 -2.82352462e+00 4.22716015e+00 -2.41014412 0.33676978 881.25 -5.33195354e+00 -2.75444960e+00 6.00139327e+00 -2.66475897 0.56778035 881.50 -4.85710943e+00 -2.44198061e+00 5.43643094e+00 -2.67573615 0.54100504 881.75 -4.04281220e+00 -1.79107333e+00 4.42179536e+00 -2.72455292 0.49219920 882.00 -4.27066891e+00 -1.79929917e+00 4.63423030e+00 -2.74284691 0.51713991 882.25 -4.76572820e+00 -4.77553005e-01 4.78959520e+00 -3.04172037 0.53315219 882.50 -4.32149377e+00 -2.44225427e-01 4.32838937e+00 -3.08513858 0.48985476 882.75 -3.27182923e+00 8.30510863e-01 3.37559103e+00 2.89300610 0.34285860 883.00 -2.84454802e+00 1.26173877e+00 3.11182232e+00 2.72410388 0.28777506 883.25 -3.04300768e+00 1.66057580e+00 3.46661329e+00 2.64205513 0.32539005 883.50 -3.23119267e+00 2.04760190e+00 3.82534699e+00 2.57676269 0.37163919 883.75 -2.05661296e+00 2.33821733e+00 3.11398734e+00 2.29220569 0.29021871 884.00 -2.40593413e+00 2.48896781e+00 3.46171631e+00 2.33923282 0.32387874 884.25 -2.26508393e+00 2.49078464e+00 3.36669175e+00 2.30877276 0.32735697 884.50 -1.32892658e+00 2.77850675e+00 3.07995870e+00 2.01692400 0.29215378 884.75 -7.63106096e-01 3.77590642e+00 3.85224613e+00 1.77020913 0.32270541 885.00 -6.18846780e-01 4.91568723e+00 4.95448810e+00 1.69602972 0.47330215 885.25 -2.22131097e-01 5.17578150e+00 5.18054596e+00 1.61368741 0.58981685 885.50 -4.01445131e-01 5.37158422e+00 5.38656432e+00 1.64539261 0.71015293 885.75 -4.65388225e-01 6.23080162e+00 6.24815773e+00 1.64534944 0.85266132 886.00 -1.51299687e+00 6.21401277e+00 6.39555426e+00 1.80963054 0.84753344 886.25 -2.41766701e+00 6.57073478e+00 7.00140481e+00 1.92336722 0.87461761 886.50 -2.93467024e+00 7.17935733e+00 7.75599517e+00 1.95883586 0.88521016 886.75 -3.06557121e+00 8.09724425e+00 8.65812285e+00 1.93271451 0.87866951 887.00 -2.19017425e+00 8.67339585e+00 8.94565027e+00 1.81814191 0.86994199 887.25 -1.01821866e+00 9.02347352e+00 9.08074026e+00 1.68316211 0.87129580 887.50 8.98364747e-01 8.69003163e+00 8.73634414e+00 1.46778349 0.84505823 887.75 1.31043714e+00 7.11894427e+00 7.23855047e+00 1.38875672 0.75360509 888.00 6.49126436e-01 5.89919233e+00 5.93479867e+00 1.46120074 0.76197692 888.25 -2.41095879e-01 5.67824824e+00 5.68336435e+00 1.61323039 0.71737418 888.50 -1.00910571e+00 5.34865925e+00 5.44301848e+00 1.75726964 0.75159047 888.75 -1.78595300e+00 4.94365311e+00 5.25636131e+00 1.91746849 0.70867555 889.00 -2.15423641e+00 4.82143663e+00 5.28081297e+00 1.99098915 0.74028934 889.25 -2.14178525e+00 4.60541607e+00 5.07908469e+00 2.00610163 0.74740629 889.50 -2.42917778e+00 4.05317907e+00 4.72537462e+00 2.11072049 0.69265651 889.75 -2.76253514e+00 4.00741632e+00 4.86733869e+00 2.17434266 0.74783578 890.00 -2.70062876e+00 4.33330592e+00 5.10597061e+00 2.12811891 0.80746830 890.25 -2.72696693e+00 4.35643874e+00 5.13954347e+00 2.13008742 0.81991069 890.50 -3.53409041e+00 4.33735428e+00 5.59485810e+00 2.25449869 0.81771821 890.75 -3.42667606e+00 4.26373521e+00 5.47005912e+00 2.24777677 0.80883522 891.00 -2.78294769e+00 3.68998990e+00 4.62177708e+00 2.21697265 0.75921909 891.25 -3.02136490e+00 3.43061226e+00 4.57140529e+00 2.29284959 0.76239081 891.50 -2.57992053e+00 3.09238113e+00 4.02725849e+00 2.26609471 0.65710671 891.75 -2.23739665e+00 2.93511347e+00 3.69064152e+00 2.22211438 0.65522121 892.00 -2.27391071e+00 3.18180011e+00 3.91082113e+00 2.19129474 0.71227823 892.25 -2.07481247e+00 2.75355824e+00 3.44774271e+00 2.21653514 0.69729924 892.50 -1.98756192e+00 2.17432839e+00 2.94586257e+00 2.31134918 0.73832789 892.75 -2.09523256e+00 2.04121883e+00 2.92516218e+00 2.36925173 0.72860771 893.00 -2.89145806e+00 1.95911604e+00 3.49265878e+00 2.54609119 0.80578225 893.25 -3.01846646e+00 2.12063466e+00 3.68893360e+00 2.52915488 0.81121404 893.50 -3.29284817e+00 1.53415523e+00 3.63269615e+00 2.70559093 0.88401541 893.75 -3.27292631e+00 1.47645607e+00 3.59053884e+00 2.71781444 0.87965328 894.00 -3.38655506e+00 1.61168102e+00 3.75050275e+00 2.69740557 0.85065398 894.25 -3.27958118e+00 1.37416676e+00 3.55583844e+00 2.74480925 0.84473704 894.50 -3.24758962e+00 9.77884955e-01 3.39162163e+00 2.84911691 0.80873157 894.75 -2.83018319e+00 8.53658995e-01 2.95612425e+00 2.84864409 0.64415707 895.00 -2.65266942e+00 8.38000625e-01 2.78188786e+00 2.83560562 0.62224523 895.25 -2.63601427e+00 1.01131793e+00 2.82335531e+00 2.77525642 0.51873545 895.50 -3.13312026e+00 1.05383989e+00 3.30560450e+00 2.81712529 0.54303382 895.75 -3.42422313e+00 7.08367995e-01 3.49672551e+00 2.93760043 0.54925570 896.00 -3.47778435e+00 1.58688638e-01 3.48140289e+00 3.09599505 0.45186233 896.25 -4.05665587e+00 -3.09374863e-01 4.06843577e+00 -3.06547647 0.62567696 896.50 -3.96949007e+00 -4.86682496e-01 3.99921383e+00 -3.01959572 0.64398093 896.75 -3.19147903e+00 -4.58490368e-01 3.22424437e+00 -2.99890812 0.44690629 897.00 -3.28273764e+00 -5.80388354e-01 3.33364921e+00 -2.96660091 0.42298152 897.25 -2.91498928e+00 -7.42235098e-01 3.00800190e+00 -2.89226389 0.39577713 897.50 -2.76362826e+00 -8.80351013e-01 2.90045843e+00 -2.83320648 0.36490610 897.75 -3.01707473e+00 -1.22068810e+00 3.25466117e+00 -2.75713285 0.47098656 898.00 -2.80410054e+00 -1.23128803e+00 3.06252347e+00 -2.72783781 0.47472284 898.25 -2.22466688e+00 -8.19943174e-01 2.37095962e+00 -2.78847204 0.34187110 898.50 -1.50516656e+00 -4.31971272e-01 1.56592642e+00 -2.86211180 0.21914178 898.75 -1.37957007e+00 -1.08803164e-01 1.38385393e+00 -3.06288812 0.16336058 899.00 -1.06812062e+00 -3.56938206e-01 1.12618229e+00 -2.81908563 0.12615249 899.25 -5.07973770e-01 -1.15555218e-01 5.20951399e-01 -2.91791645 0.03647762 899.50 -4.98341626e-01 2.48918816e-01 5.57050225e-01 2.67834966 0.04300965 899.75 -3.80147967e-01 1.10910508e-01 3.95996992e-01 2.85771608 0.02945156 900.00 -3.17406610e-01 4.08769185e-02 3.20027934e-01 3.01351355 0.02241646 900.25 -4.12700990e-02 2.18179740e-01 2.22048689e-01 1.75774396 0.01094040 900.50 -8.17679787e-02 2.73615753e-01 2.85572377e-01 1.86119073 0.01216047 900.75 1.59712454e-02 2.49619145e-01 2.50129563e-01 1.50690097 0.01007384 901.00 -4.27708645e-02 2.20946661e-01 2.25048381e-01 1.76201130 0.01014208 901.25 8.77964855e-02 9.54807039e-02 1.29710399e-01 0.82730038 0.00200928 901.50 1.07746070e-01 2.66463624e-01 2.87423170e-01 1.18654073 0.01085461 901.75 8.29581773e-01 -1.68376924e-01 8.46496725e-01 -0.20024588 0.12548805 902.00 1.02435288e+00 -2.77869727e-01 1.06137195e+00 -0.26488927 0.19161535 902.25 8.02338446e-01 1.22934675e-01 8.11701864e-01 0.15203806 0.09412997 902.50 1.08512153e+00 2.63608576e-01 1.11668179e+00 0.23831356 0.21455778 902.75 1.55132146e+00 4.95622908e-02 1.55211297e+00 0.03193757 0.43978155 903.00 1.75952239e+00 -1.09385061e-02 1.75955639e+00 -0.00621667 0.55593532 903.25 1.60318648e+00 1.03142420e-01 1.60650093e+00 0.06424734 0.52855903 903.50 1.57878321e+00 -1.49766001e-01 1.58587083e+00 -0.09457864 0.49724875 903.75 1.89228731e+00 -1.91728949e-01 1.90197562e+00 -0.10097667 0.70718547 904.00 1.83529300e+00 -7.51936503e-02 1.83683273e+00 -0.04094802 0.74142061 904.25 1.81967932e+00 -1.91938989e-01 1.82977414e+00 -0.10509097 0.72386904 904.50 1.77596774e+00 -2.45882975e-02 1.77613794e+00 -0.01384413 0.76706713 904.75 1.88803073e+00 3.18898161e-02 1.88830003e+00 0.01688891 0.85480984 905.00 2.07082476e+00 -1.16838586e-01 2.07411823e+00 -0.05636153 0.87108936 905.25 2.28831924e+00 -2.68737744e-01 2.30404534e+00 -0.11690344 0.90479345 905.50 2.24514370e+00 -2.85026067e-01 2.26316373e+00 -0.12627676 0.90159062 905.75 2.24677833e+00 -3.41076388e-01 2.27251974e+00 -0.15065659 0.91791531 906.00 2.15530573e+00 -4.37920510e-01 2.19934471e+00 -0.20045382 0.92328883 906.25 2.05488797e+00 -5.02573576e-01 2.11545380e+00 -0.23986600 0.93319029 906.50 2.05510056e+00 -5.12627685e-01 2.11807116e+00 -0.24445309 0.94661100 906.75 2.04297018e+00 -5.62448143e-01 2.11897972e+00 -0.26865349 0.94118807 907.00 2.10126183e+00 -5.98042912e-01 2.18470973e+00 -0.27727964 0.92928786 907.25 1.98540241e+00 -7.65302930e-01 2.12779494e+00 -0.36791366 0.92169808 907.50 1.80762476e+00 -8.54200963e-01 1.99929152e+00 -0.44145102 0.91710220 907.75 1.74592467e+00 -8.13285913e-01 1.92605476e+00 -0.43593134 0.92380111 908.00 1.60109900e+00 -8.02624428e-01 1.79101200e+00 -0.46468382 0.93054060 908.25 1.54663669e+00 -7.63758200e-01 1.72493815e+00 -0.45869039 0.95516494 908.50 1.48713193e+00 -7.61863276e-01 1.67092699e+00 -0.47344210 0.94950646 908.75 1.42396295e+00 -7.34176794e-01 1.60208802e+00 -0.47603932 0.94462034 909.00 1.23295978e+00 -6.57729999e-01 1.39742569e+00 -0.49005295 0.91037566 909.25 1.12292491e+00 -5.69986262e-01 1.25930325e+00 -0.46970173 0.87961800 909.50 1.20634574e+00 -4.35062889e-01 1.28240001e+00 -0.34612670 0.89423202 909.75 1.17051673e+00 -3.83475413e-01 1.23173163e+00 -0.31659261 0.89121667 910.00 1.13081709e+00 -3.13669277e-01 1.17351425e+00 -0.27058018 0.84324827 910.25 1.16991074e+00 -2.54923015e-01 1.19736247e+00 -0.21454593 0.79600610 910.50 1.09122080e+00 -1.88111025e-02 1.09138293e+00 -0.01723688 0.67941808 910.75 1.01735133e+00 5.76641427e-02 1.01898424e+00 0.05662008 0.63130366 911.00 1.08337519e+00 2.72090543e-01 1.11702062e+00 0.24606147 0.53087024 911.25 8.65753246e-01 3.65427765e-01 9.39715986e-01 0.39940521 0.43348269 911.50 6.74229331e-01 6.60798581e-01 9.44055060e-01 0.77533823 0.33069387 911.75 7.41761544e-01 8.52645830e-01 1.13013942e+00 0.85483213 0.32155925 912.00 1.16335497e+00 1.38904441e+00 1.81186069e+00 0.87359126 0.41631971 912.25 1.25913617e+00 1.69120489e+00 2.10845865e+00 0.93081154 0.42324025 912.50 2.19309222e+00 2.38679803e+00 3.24136673e+00 0.82766783 0.49062051 912.75 2.59993129e+00 2.23271695e+00 3.42704941e+00 0.70955775 0.44078600 913.00 2.34107109e+00 1.03421686e+00 2.55933944e+00 0.41598949 0.28774082 913.25 2.84985445e+00 5.23625325e-01 2.89755999e+00 0.18171084 0.28116643 913.50 3.06022101e+00 -2.26966764e+00 3.81003200e+00 -0.63814719 0.50074479 913.75 2.91226590e+00 -2.66996297e+00 3.95094861e+00 -0.74201927 0.53124600 914.00 1.73455887e+00 -2.74791791e+00 3.24957648e+00 -1.00773198 0.40750675 914.25 9.64324413e-01 -3.05955565e+00 3.20792804e+00 -1.26546770 0.42384750 914.50 1.19947611e+00 -4.13781996e+00 4.30816631e+00 -1.28864852 0.71154321 914.75 4.16270895e-01 -4.29243153e+00 4.31256883e+00 -1.47412076 0.74989338 915.00 -4.51254528e-01 -3.87380978e+00 3.90000421e+00 -1.68676224 0.75915780 915.25 -9.07675727e-01 -3.78405835e+00 3.89139729e+00 -1.80621680 0.73583931 915.50 -1.14005952e+00 -3.70175552e+00 3.87333572e+00 -1.86955628 0.79946069 915.75 -1.16336354e+00 -3.37756123e+00 3.57230103e+00 -1.90250839 0.77187689 916.00 -1.73265771e+00 -2.75470312e+00 3.25430361e+00 -2.13225373 0.73988880 916.25 -2.76032944e+00 -2.77419399e+00 3.91351133e+00 -2.35368939 0.75223459 916.50 -3.67905600e+00 -2.29419187e+00 4.33575477e+00 -2.58401391 0.80771915 916.75 -4.26505197e+00 -4.71689598e-01 4.29105574e+00 -3.03144616 0.73220838 917.00 -4.30645531e+00 9.36739380e-01 4.40715758e+00 2.92740926 0.74228106 917.25 -3.54969418e+00 2.14463490e+00 4.14726266e+00 2.59810928 0.62192340 917.50 -3.26634621e+00 3.36896449e+00 4.69243426e+00 2.34073024 0.63578649 917.75 -2.14170496e+00 3.46569797e+00 4.07405972e+00 2.12432597 0.58581419 918.00 -3.45264677e-01 3.61321416e+00 3.62967275e+00 1.66606318 0.56462800 918.25 1.23281325e+00 3.70241477e+00 3.90226904e+00 1.24936790 0.58398401 918.50 2.15774270e+00 3.50696718e+00 4.11760517e+00 1.01922221 0.65954773 918.75 2.19373851e+00 2.68936137e+00 3.47061280e+00 0.88654935 0.64925136 919.00 2.36444050e+00 2.19763266e+00 3.22802853e+00 0.74885040 0.66000846 919.25 2.32737913e+00 1.12851258e+00 2.58654871e+00 0.45148312 0.60325202 919.50 2.52988897e+00 1.05087081e+00 2.73946485e+00 0.39369615 0.66107747 919.75 2.88114640e+00 1.15562052e+00 3.10426535e+00 0.38145211 0.67391944 920.00 3.15560165e+00 1.00077527e+00 3.31049436e+00 0.30710869 0.74978122 920.25 3.01906239e+00 5.11553243e-01 3.06209478e+00 0.16784690 0.78676903 920.50 2.86128740e+00 3.28337184e-01 2.88006439e+00 0.11425182 0.77453070 920.75 2.64573907e+00 4.28248772e-03 2.64574254e+00 0.00161863 0.79087257 921.00 2.53878372e+00 6.38300739e-03 2.53879175e+00 0.00251419 0.80763896 921.25 2.06754542e+00 5.30384124e-02 2.06822560e+00 0.02564722 0.74822493 921.50 2.05135820e+00 5.52089706e-03 2.05136563e+00 0.00269133 0.75662105 921.75 2.13067358e+00 -2.18069930e-01 2.14180401e+00 -0.10199274 0.77028658 922.00 2.18938476e+00 -1.15602384e-01 2.19243461e+00 -0.05275232 0.74734067 922.25 2.42768654e+00 4.18460203e-01 2.46348754e+00 0.17069263 0.75294454 922.50 2.64108439e+00 1.78772113e-01 2.64712792e+00 0.06758581 0.73645673 922.75 2.78181000e+00 -2.55760313e-02 2.78192757e+00 -0.00919377 0.77322480 923.00 2.59234137e+00 -1.60880826e-01 2.59732871e+00 -0.06198056 0.72987440 923.25 2.14025480e+00 -1.51314658e-01 2.14559706e+00 -0.07058192 0.55018997 923.50 2.51206745e+00 -3.86862026e-01 2.54168155e+00 -0.15280103 0.64487409 923.75 2.94981116e+00 -6.06322774e-01 3.01148023e+00 -0.20272281 0.82938369 924.00 3.00691602e+00 -6.70728962e-01 3.08081504e+00 -0.21946914 0.84269516 924.25 2.93003918e+00 -1.01113719e+00 3.09960127e+00 -0.33229701 0.85877414 924.50 2.95585793e+00 -1.17439960e+00 3.18061480e+00 -0.37818751 0.84803692 924.75 3.05549888e+00 -1.23146042e+00 3.29432363e+00 -0.38311647 0.81910740 925.00 3.01505654e+00 -1.21619063e+00 3.25110529e+00 -0.38341025 0.76818968 925.25 2.90461706e+00 -1.30621939e+00 3.18480916e+00 -0.42260817 0.77527516 925.50 2.54619096e+00 -1.57451101e+00 2.99368892e+00 -0.55382397 0.79566860 925.75 2.37263705e+00 -1.81460818e+00 2.98700677e+00 -0.65291010 0.86350449 926.00 2.49224135e+00 -1.85971683e+00 3.10963239e+00 -0.64106630 0.89854995 926.25 2.58930201e+00 -1.81858297e+00 3.16413162e+00 -0.61229797 0.93149953 926.50 2.57191876e+00 -1.79781522e+00 3.13797796e+00 -0.61006600 0.90446302 926.75 2.56966701e+00 -1.90223380e+00 3.19713653e+00 -0.63724135 0.91363943 927.00 2.42645643e+00 -1.90308781e+00 3.08373702e+00 -0.66509879 0.85838134 927.25 2.63603964e+00 -1.77107649e+00 3.17575455e+00 -0.59159641 0.85614524 927.50 2.73397027e+00 -1.76332289e+00 3.25329081e+00 -0.57282953 0.84783040 927.75 2.77409498e+00 -2.15843422e+00 3.51488850e+00 -0.66122390 0.84335963 928.00 3.11212775e+00 -2.59749091e+00 4.05367711e+00 -0.69550601 0.80572765 928.25 3.57656365e+00 -2.88069943e+00 4.59241078e+00 -0.67804787 0.83202871 928.50 3.32951671e+00 -2.96495818e+00 4.45832463e+00 -0.72754557 0.80206299 928.75 3.40237855e+00 -3.59167139e+00 4.94735113e+00 -0.81245640 0.81498507 929.00 2.98683506e+00 -4.68371339e+00 5.55502968e+00 -1.00311180 0.79185193 929.25 2.81268188e+00 -4.93851311e+00 5.68331691e+00 -1.05307489 0.74980538 929.50 3.59890719e+00 -4.98079053e+00 6.14494973e+00 -0.94509102 0.73273465 929.75 4.07032247e+00 -5.60058499e+00 6.92344403e+00 -0.94233065 0.73738317 930.00 3.11537333e+00 -7.29310420e+00 7.93063175e+00 -1.16709166 0.76626200 930.25 2.76629572e+00 -8.68205917e+00 9.11210972e+00 -1.26234381 0.81522826 930.50 2.52283952e+00 -1.02293872e+01 1.05358949e+01 -1.32899509 0.86632979 930.75 2.19353152e+00 -1.07493250e+01 1.09708509e+01 -1.36949782 0.84040972 931.00 1.21427607e+00 -1.08896634e+01 1.09571545e+01 -1.45974785 0.71345499 931.25 7.30899144e-01 -1.25273660e+01 1.25486698e+01 -1.51251819 0.71339708 931.50 7.81477468e-01 -1.45074580e+01 1.45284908e+01 -1.51698105 0.72789886 931.75 -1.25917508e+00 -1.32464152e+01 1.33061278e+01 -1.66556935 0.55683040 932.00 -7.16433953e+00 -9.97986163e+00 1.22851699e+01 -2.19342154 0.39222978 932.25 -7.26553744e+00 -1.08128796e+01 1.30271409e+01 -2.16243643 0.35586941 932.50 -1.07208075e+01 -5.00640417e+00 1.18321509e+01 -2.70470811 0.26242556 932.75 -1.21315099e+01 -3.27941312e+00 1.25669440e+01 -2.87758079 0.28805923 933.00 -1.30554936e+01 2.02541984e+00 1.32116706e+01 2.98768035 0.23449836 933.25 -1.28840833e+01 5.84309555e+00 1.41471328e+01 2.71582140 0.26291114 933.50 -8.08641357e+00 7.40414589e+00 1.09640987e+01 2.40021014 0.18004859 933.75 -5.55676376e+00 7.29096890e+00 9.16710702e+00 2.22202401 0.16289079 934.00 -1.11948515e+00 1.06114393e+01 1.06703276e+01 1.67590548 0.28044936 934.25 -6.32205405e-01 9.02201776e+00 9.04414109e+00 1.64075558 0.29708534 934.50 -1.26618582e+00 8.22987509e+00 8.32670827e+00 1.72345173 0.38634191 934.75 2.77485019e-01 9.31973412e+00 9.32386412e+00 1.54103120 0.35612804 935.00 1.89329673e+00 8.65416182e+00 8.85884244e+00 1.35541670 0.35485322 935.25 2.07068248e+00 8.44395982e+00 8.69414650e+00 1.33031542 0.38577390 935.50 2.37710493e+00 1.03342499e+01 1.06041194e+01 1.34470704 0.60939975 935.75 3.38500638e+00 9.40791684e+00 9.99835824e+00 1.22541424 0.55369446 936.00 3.65463536e+00 1.00691910e+01 1.07119078e+01 1.22262969 0.66091831 936.25 3.01380131e+00 9.44211392e+00 9.91143348e+00 1.26183091 0.68843657 936.50 2.95638695e+00 8.88773602e+00 9.36654020e+00 1.24967290 0.74776344 936.75 3.04634780e+00 8.48378189e+00 9.01414389e+00 1.22605633 0.76724322 937.00 3.66770426e+00 7.32169058e+00 8.18896865e+00 1.10639956 0.74823180 937.25 3.42403537e+00 6.52326112e+00 7.36728945e+00 1.08743065 0.70397878 937.50 2.89098114e+00 6.49341613e+00 7.10789877e+00 1.15192682 0.71716487 937.75 3.13837997e+00 6.12495990e+00 6.88219170e+00 1.09728440 0.69796652 938.00 2.99626262e+00 6.01646689e+00 6.72126948e+00 1.10874173 0.74007080 938.25 3.32996166e+00 6.62825429e+00 7.41770851e+00 1.10523939 0.80227561 938.50 3.47114856e+00 6.89031614e+00 7.71526596e+00 1.10413565 0.79096316 938.75 3.14623368e+00 7.11573774e+00 7.78026414e+00 1.15448840 0.77246836 939.00 2.76378189e+00 7.61519263e+00 8.10121282e+00 1.22264933 0.77273738 939.25 3.41352592e+00 7.06681705e+00 7.84806106e+00 1.12081191 0.80101253 939.50 3.78374849e+00 6.91799067e+00 7.88513460e+00 1.07030296 0.78656725 939.75 4.34743378e+00 6.73590385e+00 8.01701822e+00 0.99765312 0.76583544 940.00 4.45814725e+00 6.59040141e+00 7.95666184e+00 0.97604388 0.71493472 940.25 4.79727303e+00 7.03599739e+00 8.51581398e+00 0.97237723 0.73419837 940.50 5.35124910e+00 6.91836481e+00 8.74640718e+00 0.91243367 0.80051465 940.75 5.77265537e+00 7.22722745e+00 9.24966846e+00 0.89682586 0.72880430 941.00 6.20066349e+00 7.53658813e+00 9.75952808e+00 0.88234164 0.77682104 941.25 7.36880325e+00 6.90659789e+00 1.00995226e+01 0.75303172 0.84057421 941.50 7.29813465e+00 6.55240990e+00 9.80799903e+00 0.73160927 0.82719902 941.75 7.90513592e+00 6.07671604e+00 9.97084007e+00 0.65536511 0.81275295 942.00 8.70318744e+00 5.78955948e+00 1.04529647e+01 0.58700240 0.81596583 942.25 8.92584955e+00 5.05124035e+00 1.02560138e+01 0.51497716 0.76026193 942.50 9.28704651e+00 3.60521926e+00 9.96227076e+00 0.37029162 0.73137499 942.75 1.14332212e+01 1.94035886e+00 1.15967039e+01 0.16811057 0.72429233 943.00 1.19854738e+01 1.42432055e+00 1.20698082e+01 0.11828251 0.77954642 943.25 1.11278897e+01 4.75017150e-01 1.11380236e+01 0.04266118 0.77866143 943.50 1.10522655e+01 4.50312972e-01 1.10614355e+01 0.04072143 0.77390353 943.75 1.08347792e+01 -1.24034443e+00 1.09055442e+01 -0.11398186 0.78223085 944.00 1.07232377e+01 -2.30101331e+00 1.09673373e+01 -0.21137655 0.76817686 944.25 1.04878835e+01 -2.86785686e+00 1.08729160e+01 -0.26691975 0.79017419 944.50 9.86390324e+00 -3.44130605e+00 1.04469696e+01 -0.33567557 0.79172624 944.75 9.67484365e+00 -4.06872197e+00 1.04955752e+01 -0.39809248 0.78931356 945.00 9.06356179e+00 -4.59230517e+00 1.01605816e+01 -0.46897553 0.77821343 945.25 6.97884142e+00 -5.34660676e+00 8.79149768e+00 -0.65373624 0.76792479 945.50 7.54367981e+00 -5.35329134e+00 9.25012612e+00 -0.61716601 0.84436760 945.75 7.25037211e+00 -5.22370982e+00 8.93616473e+00 -0.62433563 0.80604497 946.00 6.53958875e+00 -5.77694981e+00 8.72578766e+00 -0.72355721 0.80828050 946.25 6.48201587e+00 -6.76900029e+00 9.37208059e+00 -0.80705232 0.85882884 946.50 5.65166648e+00 -6.65321375e+00 8.72963843e+00 -0.86661344 0.82257899 946.75 5.35259553e+00 -5.99486174e+00 8.03670618e+00 -0.84193785 0.76435304 947.00 5.11569149e+00 -7.15001606e+00 8.79164541e+00 -0.94975666 0.86220315 947.25 4.54164507e+00 -7.64956690e+00 8.89620221e+00 -1.03501266 0.89706127 947.50 4.07924355e+00 -7.53341691e+00 8.56694802e+00 -1.07451288 0.85370255 947.75 2.92249570e+00 -7.79481199e+00 8.32466667e+00 -1.21208851 0.85496354 948.00 1.96807939e+00 -8.07157898e+00 8.30805174e+00 -1.33163470 0.82280524 948.25 7.62306563e-01 -8.29474312e+00 8.32969836e+00 -1.47915139 0.79029260 948.50 5.90912567e-01 -7.92499441e+00 7.94699403e+00 -1.49637090 0.78748285 948.75 -2.32664170e-03 -7.53997879e+00 7.53997915e+00 -1.57110490 0.82216587 949.00 -4.93457401e-01 -6.95252742e+00 6.97001705e+00 -1.64165276 0.85506644 949.25 -3.35655219e-01 -6.38170967e+00 6.39053071e+00 -1.62334435 0.80233269 949.50 -9.70553973e-01 -5.41172251e+00 5.49806471e+00 -1.74825271 0.69554883 949.75 -1.49164101e+00 -4.73229907e+00 4.96181896e+00 -1.87614300 0.67498774 950.00 -9.85983181e-01 -3.75736731e+00 3.88458131e+00 -1.82742355 0.59064104 950.25 -1.14624014e+00 -3.34959148e+00 3.54028665e+00 -1.90050820 0.65790150 950.50 -1.07611620e+00 -3.20662769e+00 3.38237892e+00 -1.89457763 0.67178723 950.75 -8.99073530e-01 -3.00328866e+00 3.13497624e+00 -1.86166862 0.69223257 951.00 -2.87060797e-01 -2.27266750e+00 2.29072510e+00 -1.69644103 0.50243091 951.25 1.43755199e-01 -2.01591760e+00 2.02103670e+00 -1.49960678 0.39453418 951.50 4.07470697e-02 -2.46471993e+00 2.46505672e+00 -1.55426570 0.55963028 951.75 4.15556343e-02 -2.30221685e+00 2.30259187e+00 -1.55274802 0.51528741 952.00 2.09943302e-01 -2.45378619e+00 2.46275107e+00 -1.48544527 0.51295642 952.25 1.57653427e-01 -2.87261320e+00 2.87693608e+00 -1.51596979 0.60892206 952.50 1.48804385e-01 -3.20130621e+00 3.20476274e+00 -1.52434736 0.63504282 952.75 2.36415798e-01 -3.32543582e+00 3.33382900e+00 -1.49982256 0.71164729 953.00 4.96745978e-01 -3.22290431e+00 3.26096132e+00 -1.41786981 0.71611329 953.25 5.96556806e-01 -3.54880829e+00 3.59859977e+00 -1.40425280 0.68706803 953.50 3.13880693e-01 -4.09646686e+00 4.10847439e+00 -1.49432345 0.68960211 953.75 2.44601166e-01 -4.28156333e+00 4.28854454e+00 -1.51372942 0.62842122 954.00 -1.06733066e+00 -4.88166322e+00 4.99698215e+00 -1.78604979 0.59570807 954.25 -1.18174672e+00 -5.00243647e+00 5.14012606e+00 -1.80277760 0.62577718 954.50 -1.81465945e+00 -4.16401493e+00 4.54224716e+00 -1.98177531 0.69103251 954.75 -2.39071634e+00 -3.88987100e+00 4.56581001e+00 -2.12188231 0.69645840 955.00 -2.99592308e+00 -3.82478473e+00 4.85844968e+00 -2.23526608 0.72934135 955.25 -3.00032341e+00 -3.22655612e+00 4.40597378e+00 -2.31987883 0.70682909 955.50 -2.91474528e+00 -2.60974837e+00 3.91235563e+00 -2.41134662 0.62615000 955.75 -3.19018922e+00 -1.96360971e+00 3.74607399e+00 -2.58984302 0.59421905 956.00 -3.84529145e+00 -1.02698494e+00 3.98007090e+00 -2.88060817 0.61975361 956.25 -4.14977009e+00 -5.89972431e-01 4.19149845e+00 -3.00036915 0.62435522 956.50 -3.93759334e+00 4.26880652e-01 3.96066514e+00 3.03360284 0.58214133 956.75 -3.55771981e+00 7.88271332e-01 3.64400082e+00 2.92354871 0.53902466 957.00 -3.09210669e+00 1.49817919e+00 3.43593723e+00 2.69040774 0.47826557 957.25 -2.43253472e+00 1.41680816e+00 2.81506137e+00 2.61418418 0.40056632 957.50 -1.64042654e+00 1.19299118e+00 2.02835578e+00 2.51281483 0.30966046 957.75 -1.25595570e+00 1.43905997e+00 1.91005716e+00 2.28835692 0.27211063 958.00 -8.49799751e-01 1.71062154e+00 1.91007478e+00 2.03186330 0.26072773 958.25 -7.91976978e-01 1.94393526e+00 2.09907404e+00 1.95767352 0.31854027 958.50 -6.24744271e-01 2.76688105e+00 2.83653595e+00 1.79286608 0.49008949 958.75 -1.20164052e-01 3.18937918e+00 3.19164204e+00 1.60845483 0.60726432 959.00 3.60789955e-01 3.50340929e+00 3.52193783e+00 1.46817555 0.69545058 959.25 1.31065956e+00 2.57905599e+00 2.89298432e+00 1.10061540 0.53452629 959.50 2.54836088e+00 1.90922231e+00 3.18422251e+00 0.64298648 0.56217598 959.75 3.78373453e+00 1.36230166e+00 4.02150628e+00 0.34559237 0.76247346 960.00 4.02636680e+00 1.17616958e+00 4.19463997e+00 0.28420895 0.82079850 960.25 3.68589032e+00 -2.06575904e-01 3.69167456e+00 -0.05598648 0.74869771 960.50 3.49193667e+00 -8.41654878e-01 3.59193605e+00 -0.23651687 0.80766453 960.75 3.70904092e+00 -1.37461091e+00 3.95557072e+00 -0.35491713 0.84265036 961.00 3.86790972e+00 -1.69299891e+00 4.22219977e+00 -0.41258152 0.86947833 961.25 3.46153753e+00 -2.58728208e+00 4.32160509e+00 -0.64185893 0.85586100 961.50 3.12354899e+00 -2.94390602e+00 4.29221865e+00 -0.75579918 0.88018985 961.75 2.58772878e+00 -3.08511640e+00 4.02669634e+00 -0.87285320 0.82533078 962.00 2.37072846e+00 -3.39163455e+00 4.13805973e+00 -0.96074659 0.85673904 962.25 2.18410136e+00 -3.60885258e+00 4.21830721e+00 -1.02655725 0.88263323 962.50 1.97131843e+00 -3.67337443e+00 4.16890586e+00 -1.07825995 0.88766043 962.75 1.59251569e+00 -3.68038381e+00 4.01015351e+00 -1.16241871 0.83629360 963.00 1.38515325e+00 -3.71347188e+00 3.96339791e+00 -1.21377356 0.82012502 963.25 1.57596872e+00 -3.88182984e+00 4.18954416e+00 -1.18514025 0.82870392 963.50 1.44887982e+00 -4.18430138e+00 4.42805045e+00 -1.23745219 0.82864779 963.75 8.25496099e-01 -4.43440282e+00 4.51058446e+00 -1.38674587 0.78275794 964.00 6.89146080e-01 -4.56950390e+00 4.62117823e+00 -1.42111019 0.79010118 964.25 6.19244293e-02 -4.62614011e+00 4.62655455e+00 -1.55741136 0.78437671 964.50 -4.25179646e-01 -4.47044409e+00 4.49061779e+00 -1.66562014 0.74724010 964.75 -6.98172474e-01 -4.47616586e+00 4.53028759e+00 -1.72552516 0.76327695 965.00 -6.61388283e-01 -4.23754729e+00 4.28885083e+00 -1.72562525 0.72545795 965.25 -1.43968802e+00 -3.98928005e+00 4.24111505e+00 -1.91713885 0.58034899 965.50 -1.47776897e+00 -3.56573696e+00 3.85982916e+00 -1.96368507 0.55916036 965.75 -1.68589091e+00 -2.51413751e+00 3.02706385e+00 -2.16149245 0.51024857 966.00 -1.59920806e+00 -2.08491804e+00 2.62761292e+00 -2.22511188 0.54132333 966.25 -1.70940973e+00 -1.91976665e+00 2.57052244e+00 -2.29829656 0.47736861 966.50 -2.00805967e+00 -2.05883547e+00 2.87595326e+00 -2.34370999 0.56243051 966.75 -2.10008565e+00 -1.76040153e+00 2.74032357e+00 -2.44395842 0.65504911 967.00 -2.20900846e+00 -1.71412850e+00 2.79606060e+00 -2.48167567 0.67917007 967.25 -2.17357414e+00 -1.48103451e+00 2.63018778e+00 -2.54347151 0.64010434 967.50 -1.74113064e+00 -1.17117667e+00 2.09837811e+00 -2.54945714 0.56353555 967.75 -1.49466201e+00 -1.10354442e+00 1.85790872e+00 -2.50560634 0.44501110 968.00 -1.46130820e+00 -1.01064452e+00 1.77674534e+00 -2.53652480 0.44831171 968.25 -1.22982160e+00 -9.48176499e-01 1.55290046e+00 -2.48479459 0.48317794 968.50 -1.21515620e+00 -9.96537515e-01 1.57152525e+00 -2.45472116 0.50845361 968.75 -1.21745172e+00 -1.13566376e+00 1.66490867e+00 -2.39093781 0.59170984 969.00 -1.19321064e+00 -1.35979909e+00 1.80908960e+00 -2.29103508 0.64446525 969.25 -1.34723968e+00 -1.47667575e+00 1.99890621e+00 -2.31039087 0.73617024 969.50 -1.48079664e+00 -1.45972010e+00 2.07931274e+00 -2.36336200 0.69750833 969.75 -1.24784278e+00 -1.37100257e+00 1.85384995e+00 -2.30920083 0.59240781 970.00 -1.16001144e+00 -1.03688645e+00 1.55587919e+00 -2.41218085 0.48502968 970.25 -1.24658406e+00 -1.22372858e+00 1.74684958e+00 -2.36544628 0.51903836 970.50 -1.20580199e+00 -1.33458013e+00 1.79862796e+00 -2.30554542 0.54483493 970.75 -1.39776565e+00 -1.16590377e+00 1.82018692e+00 -2.44639051 0.53774778 971.00 -1.89271621e+00 -9.50633013e-01 2.11803631e+00 -2.67613979 0.54735769 971.25 -2.06983867e+00 -8.99224406e-01 2.25673141e+00 -2.73175199 0.57801612 971.50 -1.89251373e+00 -1.12654315e+00 2.20243222e+00 -2.60466362 0.59109734 971.75 -1.55556094e+00 -1.27796742e+00 2.01319909e+00 -2.45385031 0.55480484 972.00 -1.24748698e+00 -1.23964322e+00 1.75867538e+00 -2.35934822 0.49549171 972.25 -1.17423949e+00 -9.15229393e-01 1.48878582e+00 -2.47952514 0.43441804 972.50 -1.33555285e+00 -5.59050450e-01 1.44783936e+00 -2.74516296 0.49285618 972.75 -1.48260564e+00 -5.70541350e-01 1.58859589e+00 -2.77423762 0.55360996 973.00 -1.51871350e+00 -8.70966379e-01 1.75073502e+00 -2.62089423 0.44794174 973.25 -1.13347254e+00 -8.21139071e-01 1.39965330e+00 -2.51464802 0.31488285 973.50 -1.35699840e+00 -7.41131693e-01 1.54619560e+00 -2.64170612 0.32563808 973.75 -1.48559773e+00 -8.65760095e-01 1.71945955e+00 -2.61393947 0.33903851 974.00 -9.13222836e-01 -6.51829953e-01 1.12198852e+00 -2.52168554 0.19604034 974.25 -1.14762755e+00 -4.26239049e-01 1.22422576e+00 -2.78597408 0.18052419 974.50 -1.60563138e+00 -1.23486548e+00 2.02557273e+00 -2.48598921 0.26812547 974.75 -2.00174870e+00 -1.34347026e+00 2.41079036e+00 -2.55049379 0.38428095 975.00 -2.12688480e+00 -8.60802112e-01 2.29447580e+00 -2.75702019 0.45117639 975.25 -2.20957782e+00 -8.12020671e-01 2.35406281e+00 -2.78941316 0.40666979 975.50 -1.76040854e+00 -4.94436567e-01 1.82852557e+00 -2.86778232 0.20729691 975.75 -1.58486592e+00 -7.18672103e-01 1.74019814e+00 -2.71586574 0.15701288 976.00 -2.09469963e+00 -7.37578907e-01 2.22076320e+00 -2.80303330 0.22262847 976.25 -2.20814792e+00 -5.24432826e-01 2.26956979e+00 -2.90841384 0.27664732 976.50 -1.76725966e+00 4.10254218e-01 1.81425335e+00 2.91349136 0.17434312 976.75 -1.92747778e+00 6.18344916e-01 2.02423344e+00 2.83115946 0.18049316 977.00 -1.98464398e+00 1.31198686e+00 2.37910093e+00 2.55747529 0.23672137 977.25 -1.81886776e+00 1.25085022e+00 2.20746601e+00 2.53916397 0.24255129 977.50 -9.46659737e-01 7.49840133e-01 1.20765263e+00 2.47169325 0.07612670 977.75 -1.13036301e+00 7.11497403e-01 1.33564557e+00 2.57980582 0.08617599 978.00 -1.94900092e+00 1.47342677e+00 2.44327466e+00 2.49426844 0.23208731 978.25 -1.24109144e+00 1.82441179e+00 2.20653265e+00 2.16815715 0.18713169 978.50 -6.50417569e-01 9.72309560e-01 1.16979866e+00 2.16037170 0.03581179 978.75 -6.86334860e-01 7.74110548e-01 1.03455434e+00 2.29616470 0.03544570 979.00 2.23794003e-01 8.64165828e-01 8.92673699e-01 1.31739223 0.02672777 979.25 1.19250327e+00 1.41460092e+00 1.85017832e+00 0.87038238 0.13128477 979.50 8.25322771e-01 1.70853541e+00 1.89743272e+00 1.12079344 0.09875371 979.75 2.28940036e-01 1.91322796e+00 1.92687695e+00 1.45170095 0.09654981 980.00 1.13653814e+00 1.50443741e+00 1.88548426e+00 0.92381172 0.10689410 980.25 1.92278371e+00 -5.02610539e-01 1.98738888e+00 -0.25567647 0.12993798 980.50 2.36400602e+00 -1.36333632e+00 2.72895775e+00 -0.52311540 0.22137325 980.75 2.63808377e+00 -8.59121829e-01 2.77445063e+00 -0.31482992 0.21054894 981.00 2.29374882e+00 -1.07780183e+00 2.53435208e+00 -0.43926800 0.19667189 981.25 2.56776553e+00 -1.09033318e+00 2.78966777e+00 -0.40155157 0.30398807 981.50 2.70035882e+00 -8.44965336e-01 2.82947065e+00 -0.30325702 0.36243638 981.75 2.62846009e+00 -1.50889770e+00 3.03077130e+00 -0.52112867 0.44615439 982.00 2.32511934e+00 -1.48651667e+00 2.75969414e+00 -0.56883716 0.44534987 982.25 1.53786461e+00 -1.78930839e+00 2.35937536e+00 -0.86082758 0.30398183 982.50 1.92008145e+00 -1.90744927e+00 2.70648767e+00 -0.78209783 0.39438943 982.75 1.93313457e+00 -1.95591027e+00 2.75001713e+00 -0.79125447 0.45821535 983.00 2.07784173e+00 -1.77805063e+00 2.73475599e+00 -0.70780543 0.43561021 983.25 1.66437756e+00 -1.60677643e+00 2.31341375e+00 -0.76779117 0.41891067 983.50 1.87243742e+00 -1.42406276e+00 2.35244057e+00 -0.65021238 0.46609348 983.75 1.43699332e+00 -6.79127520e-01 1.58939107e+00 -0.44149088 0.27840756 984.00 1.34661257e+00 -6.40798034e-01 1.49130397e+00 -0.44414917 0.23957536 984.25 1.24813933e+00 -8.45568996e-01 1.50759369e+00 -0.59544022 0.19933471 984.50 1.22097204e+00 -1.02392702e+00 1.59348652e+00 -0.69784799 0.16128264 984.75 1.62565949e+00 -1.01118206e+00 1.91448634e+00 -0.55644880 0.18240798 985.00 1.27941849e+00 -6.28684360e-01 1.42553698e+00 -0.45673019 0.10411223 985.25 1.06670139e+00 -5.92822979e-01 1.22036508e+00 -0.50724972 0.06381215 985.50 7.52580501e-01 -5.18486533e-01 9.13895888e-01 -0.60326787 0.03058233 985.75 -3.90354572e-01 -7.63678870e-01 8.57660835e-01 -2.04332422 0.02196888 986.00 -2.91177890e-01 -3.39716305e-01 4.47427906e-01 -2.27940985 0.00631688 986.25 -5.21204496e-01 -3.45530680e-01 6.25336372e-01 -2.55617000 0.01827202 986.50 -5.42360044e-01 -3.14310130e-01 6.26853472e-01 -2.61636585 0.02064268 986.75 -6.31317990e-01 -1.31224207e+00 1.45620797e+00 -2.01920890 0.11464945 987.00 -6.85421533e-01 -9.80250697e-01 1.19611626e+00 -2.18100590 0.08548941 987.25 -1.03759635e+00 2.18651550e-01 1.06038422e+00 2.93390244 0.06228305 987.50 -1.34403158e+00 -2.24795053e-02 1.34421956e+00 -3.12486878 0.10386654 987.75 -1.08888463e+00 4.19044410e-01 1.16673388e+00 2.77422472 0.10461230 988.00 -1.09220280e-01 1.26014734e+00 1.26487169e+00 1.65725289 0.13589438 988.25 -1.96464009e-01 1.33200456e+00 1.34641534e+00 1.71723550 0.12418911 988.50 -3.26304496e-01 1.62925920e+00 1.66161373e+00 1.76845902 0.17602491 988.75 -3.44240744e-01 2.21715509e+00 2.24371976e+00 1.72482883 0.35094659 989.00 4.70460856e-01 2.02783265e+00 2.08169130e+00 1.34282753 0.30597746 989.25 1.23997176e+00 1.86322240e+00 2.23810805e+00 0.98360287 0.38073739 989.50 1.18608616e+00 2.03785501e+00 2.35789173e+00 1.04369728 0.41239678 989.75 1.49243394e+00 2.25144413e+00 2.70117747e+00 0.98542088 0.52024738 990.00 1.76941949e+00 2.06971401e+00 2.72296923e+00 0.86345857 0.60642999 990.25 1.72526783e+00 1.11949640e+00 2.05665293e+00 0.57558935 0.50301492 990.50 1.75216347e+00 8.87540862e-01 1.96412973e+00 0.46886590 0.54514685 990.75 1.48934405e+00 1.05758339e+00 1.82664401e+00 0.61747245 0.55851177 991.00 1.40778081e+00 9.10994301e-01 1.67682958e+00 0.57434354 0.52977219 991.25 9.67462404e-01 6.45047294e-01 1.16278524e+00 0.58805438 0.34402182 991.50 7.42489550e-01 6.21648644e-01 9.68368612e-01 0.69704472 0.26182704 991.75 9.35766438e-01 6.50542748e-01 1.13967745e+00 0.60749572 0.26339363 992.00 8.36392876e-01 3.41431249e-01 9.03398218e-01 0.38757136 0.20732295 992.25 5.23441769e-01 1.72253519e-01 5.51055860e-01 0.31791648 0.11896583 992.50 1.91662688e-01 3.67841584e-01 4.14779480e-01 1.09045338 0.08425404 992.75 8.41958118e-02 5.01941316e-01 5.08953848e-01 1.40460317 0.11998715 993.00 -1.15835313e-01 4.14360169e-01 4.30246638e-01 1.84338977 0.09015935 993.25 -1.57380507e-01 5.01749057e-01 5.25852394e-01 1.87474109 0.16694077 993.50 -2.29492601e-01 5.01078150e-01 5.51131714e-01 2.00028114 0.22559046 993.75 -2.30224496e-01 5.58712859e-01 6.04287496e-01 1.96165778 0.33548723 994.00 -2.40465700e-01 7.30250800e-01 7.68823766e-01 1.88890522 0.45268319 994.25 -2.46946110e-01 7.53698559e-01 7.93122878e-01 1.88741933 0.43793099 994.50 9.99607018e-02 8.41845656e-01 8.47759548e-01 1.45260976 0.41400813 994.75 1.79489138e-01 8.46332407e-01 8.65155994e-01 1.36181400 0.46569706 995.00 1.03206893e-01 7.32355612e-01 7.39592054e-01 1.43079371 0.45981873 995.25 -7.61304009e-02 7.42392463e-01 7.46285741e-01 1.67298649 0.40598225 995.50 7.07373539e-02 4.70342655e-01 4.75632196e-01 1.42151974 0.20167154 995.75 8.56732223e-02 4.50648858e-01 4.58720279e-01 1.38292743 0.19449861 996.00 1.63356663e-01 3.93351717e-01 4.25923670e-01 1.17717527 0.11060287 996.25 1.73352469e-01 5.15386682e-01 5.43759607e-01 1.24632947 0.15170711 996.50 -5.81107230e-02 7.84917916e-01 7.87066065e-01 1.64469565 0.21929850 996.75 -3.42965442e-02 9.40246210e-01 9.40871505e-01 1.60725629 0.20576204 997.00 2.61553426e-01 9.31528985e-01 9.67551779e-01 1.29706575 0.24304835 997.25 1.48951873e-01 9.66663112e-01 9.78071691e-01 1.41791006 0.22057085 997.50 -1.34016699e-01 1.01627887e+00 1.02507718e+00 1.70190982 0.25081314 997.75 1.33478461e-01 8.10646320e-01 8.21561900e-01 1.40760379 0.17089183 998.00 4.59893281e-01 5.55948920e-01 7.21513015e-01 0.87967549 0.10499487 998.25 8.62585432e-01 8.52068866e-01 1.21246649e+00 0.77926490 0.24455693 998.50 1.43561206e+00 9.52005585e-01 1.72258428e+00 0.58555409 0.36129186 998.75 1.13436049e+00 5.17073211e-01 1.24665088e+00 0.42768987 0.21914935 999.00 1.73531617e+00 1.40564409e-01 1.74099987e+00 0.08082572 0.33509931 999.25 1.32912094e+00 -3.49974480e-01 1.37442519e+00 -0.25746853 0.15122736 999.50 1.66802197e+00 -1.30510902e+00 2.11792512e+00 -0.66393481 0.24950377 999.75 1.04216383e+00 -9.84736944e-01 1.43381041e+00 -0.75707338 0.09229994 1000.00 -7.62807687e-01 0.00000000e+00 7.62807687e-01 3.14159265 0.02687233