========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0061 Injection acquisition : SIG0062 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -2.46953552e-02 0.00000000e+00 2.46953552e-02 3.14159265 0.09028763 0.25 -2.25963247e-02 -9.07955942e-03 2.43522543e-02 -2.75952195 0.08415505 0.50 -1.63283394e-02 -1.28629720e-02 2.07863108e-02 -2.47435379 0.04527762 0.75 -2.42433765e-02 -5.91277016e-03 2.49540008e-02 -2.90237073 0.06919300 1.00 -1.75179417e-02 -7.04513483e-03 1.88815309e-02 -2.75921973 0.04504861 1.25 -1.66545978e-02 -4.53183933e-03 1.72601621e-02 -2.87591765 0.03755545 1.50 -1.76205761e-02 -2.75419826e-03 1.78345258e-02 -2.98654144 0.03829839 1.75 -1.73206629e-02 -1.29920530e-03 1.73693206e-02 -3.06672387 0.03623288 2.00 -1.88037708e-02 -1.22561954e-05 1.88037748e-02 -3.14094086 0.03973369 2.25 -1.72504903e-02 1.48145315e-03 1.73139862e-02 3.05592395 0.03467141 2.50 -1.74072576e-02 2.39501762e-03 1.75712471e-02 3.00486381 0.03399202 2.75 -1.48958162e-02 1.12352421e-03 1.49381273e-02 3.06630971 0.02454917 3.00 -1.53085429e-02 9.82471286e-04 1.53400370e-02 3.07750257 0.02394952 3.25 -1.83057516e-02 1.02364629e-03 1.83343501e-02 3.08573145 0.03549785 3.50 -1.93615935e-02 4.16153591e-04 1.93660653e-02 3.12010219 0.04022254 3.75 -1.77505248e-02 5.16912321e-04 1.77580497e-02 3.11247992 0.03349284 4.00 -1.62162819e-02 -4.24336772e-04 1.62218328e-02 -3.11543130 0.02665089 4.25 -1.78310312e-02 6.69425038e-03 1.90462244e-02 2.78244769 0.03469051 4.50 -1.67237586e-02 7.39412112e-03 1.82854349e-02 2.72530038 0.03246613 4.75 -2.02770120e-02 5.73311919e-03 2.10719214e-02 2.86604511 0.03899871 5.00 -2.08767932e-02 6.49592031e-03 2.18640681e-02 2.83993352 0.04258009 5.25 -1.82152626e-02 4.79046107e-03 1.88346571e-02 2.88442447 0.03052200 5.50 -1.76638437e-02 5.69973806e-03 1.85606678e-02 2.82946214 0.02721963 5.75 -1.79179501e-02 8.03529979e-03 1.96371836e-02 2.72002869 0.02887211 6.00 -1.84414484e-02 1.03584782e-02 2.11514796e-02 2.62981455 0.03155907 6.25 -1.76734379e-02 1.31116698e-02 2.20060513e-02 2.50330499 0.03733855 6.50 -2.10639416e-02 1.26531656e-02 2.45721842e-02 2.60065666 0.04519634 6.75 -2.05206350e-02 5.65388125e-03 2.12852727e-02 2.87274144 0.03146335 7.00 -1.88093626e-02 7.75641776e-03 2.03458629e-02 2.75046814 0.02831733 7.25 -1.14174137e-02 1.07073195e-02 1.56526045e-02 2.38827852 0.01758303 7.50 -1.43663744e-02 1.31040143e-02 1.94449969e-02 2.40211567 0.02573153 7.75 -1.89906581e-02 1.38566611e-02 2.35085549e-02 2.51123888 0.03373870 8.00 -1.80975262e-02 1.25164823e-02 2.20041537e-02 2.53651783 0.02971897 8.25 -1.48206171e-02 1.17130265e-02 1.88903594e-02 2.47278223 0.02289300 8.50 -1.67206327e-02 9.97346441e-03 1.94691949e-02 2.60376799 0.02349855 8.75 -1.50866149e-02 1.36100006e-02 2.03184169e-02 2.40760519 0.02425866 9.00 -1.40982213e-02 1.72632854e-02 2.22885815e-02 2.25561311 0.02804910 9.25 -1.22132193e-02 1.51593967e-02 1.94671527e-02 2.24897496 0.01907593 9.50 -1.62567826e-02 1.37740935e-02 2.13074783e-02 2.43867814 0.02363641 9.75 -1.52897760e-02 1.50060468e-02 2.14233212e-02 2.36555951 0.02396567 10.00 -1.81889390e-02 1.55300585e-02 2.39169442e-02 2.43488574 0.02861317 10.25 -1.58024834e-02 1.67791385e-02 2.30490340e-02 2.32622782 0.02456338 10.50 -1.64282344e-02 1.49693157e-02 2.22253751e-02 2.40262710 0.02202357 10.75 -2.11501874e-02 1.98089520e-02 2.89780091e-02 2.38892849 0.03324975 11.00 -1.95512157e-02 2.20952238e-02 2.95033718e-02 2.29518445 0.03734359 11.25 -2.05757251e-02 2.05631979e-02 2.90896127e-02 2.35649900 0.03854185 11.50 -1.82249912e-02 1.79806849e-02 2.56018619e-02 2.36294212 0.02800252 11.75 -1.75841162e-02 1.47801685e-02 2.29707319e-02 2.44261579 0.02058008 12.00 -1.29685349e-02 1.96913872e-02 2.35782448e-02 2.15318597 0.02055964 12.25 -1.17191757e-02 2.42845910e-02 2.69644292e-02 2.02040832 0.02601093 12.50 -1.25440574e-02 2.12185746e-02 2.46491640e-02 2.10470740 0.02184181 12.75 -1.38678612e-02 2.22342843e-02 2.62045983e-02 2.12847121 0.02389843 13.00 -1.56208529e-02 1.94743202e-02 2.49651796e-02 2.24683209 0.02155034 13.25 -1.79917195e-02 1.96303954e-02 2.66280753e-02 2.31266581 0.02379266 13.50 -6.53687257e-03 2.42120772e-02 2.50789830e-02 1.83449321 0.01796758 13.75 -6.46278955e-03 2.65585984e-02 2.73336203e-02 1.80949772 0.02066014 14.00 -1.83512904e-02 2.87699483e-02 3.41244749e-02 2.13859213 0.03388730 14.25 -1.58247690e-02 2.90337149e-02 3.30662958e-02 2.06982969 0.03169411 14.50 -1.66136203e-02 2.20270538e-02 2.75899163e-02 2.21700364 0.02131182 14.75 -1.45602663e-02 1.96164848e-02 2.44296507e-02 2.20931667 0.01568782 15.00 -1.15319696e-02 1.99121320e-02 2.30104178e-02 2.09573852 0.01407292 15.25 -8.37094504e-03 2.30428129e-02 2.45161976e-02 1.91925071 0.01492701 15.50 -1.86373680e-02 3.01369680e-02 3.54342819e-02 2.12465150 0.03243144 15.75 -1.90490727e-02 3.22232721e-02 3.74326921e-02 2.10468962 0.03392111 16.00 -2.57541687e-02 2.27181345e-02 3.43422603e-02 2.41874719 0.02861440 16.25 -1.82008388e-02 2.48552497e-02 3.08067196e-02 2.20285556 0.02354922 16.50 -1.39304434e-02 2.23624197e-02 2.63464432e-02 2.12791285 0.01607183 16.75 -9.56921354e-03 2.92887069e-02 3.08123060e-02 1.88658334 0.02054564 17.00 -1.52299061e-02 3.19838365e-02 3.54247913e-02 2.01520299 0.02549738 17.25 -1.71258061e-02 3.10594699e-02 3.54680688e-02 2.07470424 0.02546026 17.50 -2.28585833e-02 2.54776900e-02 3.42290449e-02 2.30206231 0.02502395 17.75 -2.26614186e-02 2.82906804e-02 3.62477929e-02 2.24615929 0.02722195 18.00 -1.56456092e-02 3.43678892e-02 3.77615797e-02 1.99799859 0.02690464 18.25 -1.36107978e-02 3.38703168e-02 3.65027694e-02 1.95289679 0.02592340 18.50 -8.79476255e-03 4.79549249e-02 4.87547195e-02 1.75217716 0.04208327 18.75 -1.57683669e-02 4.08286815e-02 4.37678264e-02 1.93935688 0.03403278 19.00 -2.92442024e-02 2.71372724e-02 3.98955502e-02 2.39354630 0.02768249 19.25 -2.19596478e-02 2.97260894e-02 3.69576314e-02 2.20704757 0.02377809 19.50 -6.59467482e-03 3.45795684e-02 3.52027881e-02 1.75924359 0.02115783 19.75 -7.72456503e-03 3.42218798e-02 3.50828442e-02 1.79279603 0.02042161 20.00 -1.06663747e-02 4.17289437e-02 4.30705966e-02 1.82104887 0.03192354 20.25 -1.22763503e-02 3.76434269e-02 3.95946507e-02 1.88604272 0.02614491 20.50 -1.60671533e-02 2.95353426e-02 3.36227584e-02 2.06901944 0.01895768 20.75 -2.19403039e-02 2.96226998e-02 3.68630069e-02 2.20829201 0.02107108 21.00 -2.34016014e-02 2.31872928e-02 3.29436716e-02 2.36079445 0.01560159 21.25 -1.41202168e-02 2.91618536e-02 3.24005282e-02 2.02172554 0.01513636 21.50 -1.65316170e-02 4.10689035e-02 4.42713135e-02 1.95348500 0.02759169 21.75 -1.77002094e-02 4.05587996e-02 4.42528376e-02 1.98229035 0.02724395 22.00 -1.72249718e-02 4.50733350e-02 4.82525147e-02 1.93582452 0.03118081 22.25 -1.24567505e-02 3.41517749e-02 3.63526390e-02 1.92054773 0.01784966 22.50 -7.69841604e-03 2.41351999e-02 2.53332486e-02 1.87956509 0.00826938 22.75 -7.73008807e-03 3.46054166e-02 3.54582729e-02 1.79056637 0.01627224 23.00 -6.03036892e-03 3.35452499e-02 3.40829744e-02 1.74866472 0.01453213 23.25 1.59727726e-03 3.26619336e-02 3.27009663e-02 1.52193193 0.01214288 23.50 -9.48354039e-05 2.62328689e-02 2.62330403e-02 1.57441145 0.00678570 23.75 -1.27251841e-02 4.60734114e-02 4.77984262e-02 1.84027193 0.02523465 24.00 -7.65842314e-03 5.04420431e-02 5.10201054e-02 1.72147180 0.02863604 24.25 1.34759917e-03 3.42136657e-02 3.42401948e-02 1.53142893 0.01338011 24.50 5.56445720e-03 4.85223939e-02 4.88404125e-02 1.45661698 0.02412963 24.75 8.07772765e-03 4.68603515e-02 4.75514692e-02 1.40009517 0.02441608 25.00 -8.28294511e-03 3.52350440e-02 3.61955178e-02 1.80168117 0.01285420 25.25 -2.58241556e-02 3.09454804e-02 4.03052077e-02 2.26622563 0.01626829 25.50 -3.09058836e-02 3.80537713e-02 4.90230879e-02 2.25291015 0.02517928 25.75 1.68989977e-03 4.44401747e-02 4.44722935e-02 1.53278824 0.01744005 26.00 2.88572471e-03 4.88738260e-02 4.89589448e-02 1.51182042 0.02099883 26.25 -2.43251405e-02 3.33719090e-02 4.12964499e-02 2.20066308 0.01385164 26.50 -2.61042483e-02 3.42087598e-02 4.30310472e-02 2.22262042 0.01579911 26.75 -4.75670569e-03 4.28826806e-02 4.31456897e-02 1.68126842 0.01727781 27.00 -1.51027011e-02 3.94438367e-02 4.22363331e-02 1.93646737 0.01650130 27.25 1.21768893e-03 3.93529185e-02 3.93717533e-02 1.53986341 0.01476342 27.50 -1.44096890e-04 3.78288704e-02 3.78291449e-02 1.57460549 0.01268498 27.75 8.03729562e-04 9.95274522e-03 9.98514489e-03 1.49021662 0.00083375 28.00 -7.57899022e-03 2.65154999e-02 2.75773970e-02 1.84920523 0.00596934 28.25 6.78881938e-03 3.65696885e-02 3.71944914e-02 1.38724522 0.01030167 28.50 -2.28377794e-04 3.46071474e-02 3.46079009e-02 1.57739538 0.00904380 28.75 -1.29292561e-02 2.53518840e-02 2.84584554e-02 2.04240549 0.00683388 29.00 3.74907669e-05 1.64754496e-02 1.64754923e-02 1.56852078 0.00210843 29.25 3.67380606e-02 2.90703419e-02 4.68483711e-02 0.66940538 0.01443510 29.50 -1.53062385e-03 4.62782706e-02 4.63035759e-02 1.60385863 0.01520903 29.75 -4.40831399e-02 5.38092128e-02 6.95611573e-02 2.25716471 0.03552028 30.00 -3.56417610e-02 4.13837464e-02 5.46163857e-02 2.28178558 0.01970753 30.25 -3.62424675e-03 3.32836325e-02 3.34803727e-02 1.67925875 0.00656238 30.50 2.44116831e-03 4.05958319e-02 4.06691637e-02 1.51073518 0.01036281 30.75 -1.75872689e-02 3.52877939e-02 3.94276606e-02 2.03315931 0.00875562 31.00 -1.84779227e-02 4.44418734e-02 4.81301749e-02 1.96482941 0.01526833 31.25 -3.58633601e-02 1.60821809e-02 3.93041618e-02 2.72004570 0.01086206 31.50 -2.02014222e-02 2.76722916e-02 3.42615409e-02 2.20138939 0.00839824 31.75 -7.98500861e-03 2.45620609e-02 2.58274117e-02 1.88511435 0.00468040 32.00 7.06323339e-03 4.92562046e-02 4.97600539e-02 1.42836943 0.01655933 32.25 2.80788042e-02 5.98616903e-02 6.61199002e-02 1.13220455 0.02884843 32.50 -1.02380071e-03 6.60353198e-02 6.60432558e-02 1.58629892 0.02691863 32.75 -1.41546175e-02 8.79111656e-02 8.90433952e-02 1.73043667 0.04365933 33.00 1.80459583e-02 5.12043419e-02 5.42912631e-02 1.23195813 0.01734372 33.25 3.41162297e-02 3.62518791e-02 4.97806777e-02 0.81573853 0.01319129 33.50 1.86695428e-02 5.67277998e-02 5.97209770e-02 1.25285386 0.01832468 33.75 2.18985770e-02 5.57988836e-02 5.99421645e-02 1.19681073 0.01729359 34.00 1.59347267e-03 8.55169222e-02 8.55317668e-02 1.55216506 0.03846368 34.25 5.85890636e-03 8.12396909e-02 8.14506855e-02 1.49880220 0.03549021 34.50 3.50355447e-04 5.94199433e-02 5.94209762e-02 1.56490013 0.01923800 34.75 8.98129995e-03 4.37476736e-02 4.46600794e-02 1.36831198 0.01024518 35.00 3.18761190e-02 1.34968802e-02 3.46157874e-02 0.40052879 0.00714139 35.25 2.59660928e-02 -2.50718600e-03 2.60868541e-02 -0.09625775 0.00379713 35.50 8.44157469e-03 6.61069117e-02 6.66437091e-02 1.44378790 0.02147523 35.75 2.94532598e-03 6.20913513e-02 6.21611683e-02 1.52339649 0.02078179 36.00 -4.74023950e-02 4.53640522e-02 6.56116169e-02 2.37816380 0.01878953 36.25 -8.66535228e-02 6.76038807e-02 1.09905039e-01 2.47906496 0.03645067 36.50 -1.23956033e-01 1.34444505e-01 1.82867228e-01 2.31562678 0.05216415 36.75 -6.95708665e-02 1.05741308e-01 1.26575391e-01 2.15272927 0.04161318 37.00 -6.54910974e-03 7.89026523e-02 7.91739817e-02 1.65360890 0.03037474 37.25 6.25830223e-03 5.35911397e-02 5.39553204e-02 1.45454420 0.01381810 37.50 5.18315698e-04 5.27561478e-02 5.27586939e-02 1.56097190 0.01312825 37.75 3.40553096e-03 6.77685117e-02 6.78540259e-02 1.52058615 0.02081913 38.00 -1.43346434e-02 3.96450554e-02 4.21569973e-02 1.91774512 0.00846421 38.25 -1.77512987e-02 4.70150468e-02 5.02545842e-02 1.93181503 0.01199301 38.50 1.69906687e-02 7.37414007e-02 7.56734894e-02 1.34433970 0.02325692 38.75 7.32062876e-03 7.78943128e-02 7.82375586e-02 1.47709001 0.02690890 39.00 1.35790273e-03 4.47494462e-02 4.47700439e-02 1.54046106 0.00912797 39.25 -3.04340220e-03 5.26286325e-02 5.27165558e-02 1.62855987 0.01308935 39.50 -4.90254317e-02 2.60730727e-02 5.55274534e-02 2.65280842 0.01289070 39.75 -2.18176502e-02 5.51833651e-02 5.93398150e-02 1.94730188 0.01549489 40.00 7.85173345e-03 7.98808486e-02 8.02658065e-02 1.47281799 0.02822794 40.25 7.41613385e-03 7.46586875e-02 7.50261198e-02 1.47178729 0.02420543 40.50 9.74556821e-03 8.97825813e-02 9.03099552e-02 1.46267333 0.03285249 40.75 -2.09395319e-02 8.37498221e-02 8.63278442e-02 1.81579832 0.02985154 41.00 -5.25413479e-02 7.21291333e-02 8.92367924e-02 2.20035204 0.03099458 41.25 -2.43361663e-02 6.79209777e-02 7.21492079e-02 1.91484718 0.02082605 41.50 -3.34144966e-02 5.47818571e-02 6.41683758e-02 2.11850393 0.01568397 41.75 -1.69207167e-02 7.04232776e-02 7.24275409e-02 1.80659814 0.02018375 42.00 -1.44526668e-02 8.18339264e-02 8.31003675e-02 1.74560345 0.02642697 42.25 3.49680084e-03 6.96189543e-02 6.97067171e-02 1.52061079 0.02114067 42.50 2.13496173e-02 6.02425574e-02 6.39137847e-02 1.23021216 0.01693184 42.75 1.46749996e-02 5.54581394e-02 5.73668967e-02 1.31211131 0.01204847 43.00 3.84607736e-02 3.84089529e-02 5.43551173e-02 0.78472403 0.01103079 43.25 2.31389348e-02 5.33946769e-02 5.81927988e-02 1.16186892 0.01136564 43.50 2.71441288e-02 4.76766773e-02 5.48622756e-02 1.05322784 0.00864964 43.75 -1.87651203e-02 7.55106697e-02 7.78073967e-02 1.81437169 0.01793134 44.00 -3.17644171e-02 2.86668277e-02 4.27874422e-02 2.40740775 0.00562934 44.25 9.38042065e-03 4.80914377e-02 4.89977415e-02 1.37816116 0.00748721 44.50 4.34336090e-02 6.25977346e-02 7.61902538e-02 0.96420797 0.01726237 44.75 6.77411678e-02 6.19036068e-02 9.17655837e-02 0.74040120 0.02382227 45.00 9.50825706e-02 8.75920515e-02 1.29279011e-01 0.74441642 0.04608775 45.25 3.07257927e-03 9.30367747e-02 9.30874975e-02 1.53778290 0.03137757 45.50 -4.63194940e-02 1.09165779e-01 1.18586099e-01 1.97207744 0.04832896 45.75 -4.94675783e-02 8.64964440e-02 9.96427425e-02 2.09030004 0.02756595 46.00 -3.60859579e-02 4.73191317e-02 5.95087941e-02 2.22231797 0.00983230 46.25 3.35228586e-02 1.06724634e-01 1.11865677e-01 1.26644892 0.02856110 46.50 3.70228357e-02 1.25532876e-01 1.30878544e-01 1.28400159 0.03989865 46.75 2.21101185e-02 1.01205116e-01 1.03592147e-01 1.35570740 0.02464673 47.00 1.69878560e-02 7.56695077e-02 7.75529603e-02 1.34995719 0.01486788 47.25 -3.23394731e-02 8.24504266e-02 8.85658758e-02 1.94458593 0.01958324 47.50 -2.31309287e-02 8.07594430e-02 8.40067110e-02 1.84974613 0.01699583 47.75 6.69755459e-02 4.82839869e-02 8.25655324e-02 0.62462846 0.01438206 48.00 2.27158800e-02 5.57783551e-02 6.02265398e-02 1.18405339 0.00791018 48.25 -1.23566119e-02 2.15635520e-02 2.48530206e-02 2.09115057 0.00149486 48.50 -1.34235418e-02 3.88522281e-02 4.11058038e-02 1.90345886 0.00414228 48.75 -1.41102049e-01 2.44173561e-02 1.43199147e-01 2.97024210 0.04332616 49.00 -1.18903337e-01 4.23631702e-02 1.26224569e-01 2.79933201 0.03094147 49.25 -8.22776619e-02 4.10649140e-02 9.19561896e-02 2.67866401 0.00981420 49.50 -1.53123037e-01 5.12828116e-02 1.61482480e-01 2.81842157 0.02595756 49.75 -4.62443498e-01 1.31560887e-02 4.62630599e-01 3.11315125 0.05942975 50.00 -3.41868099e-01 1.82417614e-01 3.87491913e-01 2.65143503 0.03546377 50.25 1.35073626e-02 8.52737880e-02 8.63369433e-02 1.41370158 0.00390327 50.50 2.45218895e-02 1.16193695e-01 1.18753096e-01 1.36280520 0.02056126 50.75 1.25203433e-01 1.80970984e-03 1.25216511e-01 0.01445315 0.02303434 51.00 8.79168462e-02 3.66552266e-02 9.52521784e-02 0.39501602 0.01742165 51.25 1.09766705e-01 8.30606071e-02 1.37650986e-01 0.64777615 0.03927603 51.50 5.80659685e-02 1.07749072e-01 1.22399016e-01 1.07651516 0.03296485 51.75 3.92971593e-02 1.02793004e-01 1.10048482e-01 1.20564621 0.02841430 52.00 4.43743946e-02 8.12913424e-02 9.26140877e-02 1.07113052 0.02133621 52.25 3.63145965e-02 9.63866695e-02 1.03000679e-01 1.21048395 0.02430524 52.50 4.51399754e-02 8.33252105e-02 9.47665979e-02 1.07432267 0.02126650 52.75 1.05211468e-01 8.54090991e-02 1.35514454e-01 0.68188576 0.04308460 53.00 6.93678074e-02 7.23043009e-02 1.00198826e-01 0.80612259 0.02422746 53.25 5.20679173e-03 6.05172540e-02 6.07408323e-02 1.48496955 0.00973286 53.50 3.16255012e-02 9.95121652e-02 1.04416681e-01 1.26308542 0.02517178 53.75 3.61947091e-02 1.26143479e-01 1.31233510e-01 1.29137042 0.04090801 54.00 6.68403783e-02 1.07399937e-01 1.26500525e-01 1.01410472 0.03286575 54.25 9.59604946e-02 1.42691279e-01 1.71957022e-01 0.97876318 0.05876682 54.50 9.66066766e-02 1.46798220e-01 1.75734366e-01 0.98875382 0.05804399 54.75 1.09603674e-01 1.38543166e-01 1.76655524e-01 0.90149617 0.05618570 55.00 7.22855176e-02 1.13912668e-01 1.34912164e-01 1.00534507 0.03173750 55.25 5.85340820e-02 1.24224010e-01 1.37323863e-01 1.13045480 0.03205046 55.50 3.43655514e-02 9.51882924e-02 1.01201789e-01 1.22433180 0.01795747 55.75 1.15812507e-01 1.03812716e-01 1.55530116e-01 0.73081485 0.03380793 56.00 1.19125219e-01 6.40759390e-02 1.35264718e-01 0.49349607 0.02966481 56.25 9.69323795e-02 6.08646345e-02 1.14456935e-01 0.56068786 0.01979341 56.50 1.56975918e-01 1.14467704e-01 1.94278908e-01 0.63005927 0.05644464 56.75 1.43598896e-01 9.07789968e-02 1.69886637e-01 0.56373907 0.04598398 57.00 1.05920605e-01 9.81437091e-02 1.44400008e-01 0.74730657 0.03525101 57.25 1.37278687e-01 9.21471174e-02 1.65337622e-01 0.59116294 0.04534883 57.50 1.18302199e-01 9.83734495e-02 1.53859501e-01 0.69368117 0.04286273 57.75 1.03000525e-01 1.15781142e-01 1.54965742e-01 0.84374907 0.04040422 58.00 1.11856934e-01 2.31908584e-01 2.57475368e-01 1.12138275 0.08543639 58.25 2.02243230e-01 3.98413283e-01 4.46805851e-01 1.10106996 0.17589382 58.50 2.54847424e-01 8.58261804e-01 8.95299130e-01 1.28215441 0.33277627 58.75 5.82453045e-01 9.81528464e-01 1.14133679e+00 1.03523331 0.32034780 59.00 1.66263290e+00 6.01044693e-01 1.76793747e+00 0.34688439 0.36881737 59.25 1.71047018e+00 -4.92332078e-02 1.71117859e+00 -0.02877549 0.36433082 59.50 1.27934718e+00 -3.13744391e-01 1.31725653e+00 -0.24049167 0.34522767 59.75 8.54341178e-01 -2.95524330e-01 9.04009667e-01 -0.33302567 0.30093113 60.00 7.37109271e-01 -3.04646434e-01 7.97583555e-01 -0.39191810 0.29963462 60.25 4.72846142e-01 -2.47654376e-01 5.33775387e-01 -0.48246859 0.19811362 60.50 2.31630221e-01 -3.56399842e-02 2.34356070e-01 -0.15266858 0.07738410 60.75 1.64548931e-01 1.10684755e-01 1.98311537e-01 0.59213731 0.06873728 61.00 1.76903230e-01 2.72007657e-01 3.24473294e-01 0.99416722 0.18777705 61.25 1.98313437e-01 3.18510791e-01 3.75203070e-01 1.01390522 0.17734983 61.50 4.82233113e-01 5.03315729e-01 6.97047701e-01 0.80678665 0.31170679 61.75 5.16725774e-01 4.00809036e-01 6.53952146e-01 0.65972895 0.28711404 62.00 6.89539662e-01 3.06179608e-01 7.54460667e-01 0.41788221 0.32037135 62.25 5.93755412e-01 2.52484746e-01 6.45208522e-01 0.40206848 0.27223331 62.50 7.22365733e-01 2.69432912e-01 7.70977526e-01 0.35700454 0.36660492 62.75 6.91374343e-01 1.31583067e-01 7.03784474e-01 0.18807176 0.32232191 63.00 1.07847817e+00 8.90153112e-02 1.08214550e+00 0.08235122 0.51721605 63.25 1.07934220e+00 4.61816989e-02 1.08032974e+00 0.04276081 0.49544769 63.50 1.33016481e+00 -1.56114764e-01 1.33929468e+00 -0.11683051 0.64693232 63.75 1.14337953e+00 -2.10052372e-01 1.16251398e+00 -0.18168596 0.51094767 64.00 9.05527851e-01 -3.16732878e-01 9.59322888e-01 -0.33647620 0.42811938 64.25 6.79052148e-01 -2.90469621e-01 7.38569171e-01 -0.40420392 0.35608720 64.50 7.61913962e-01 -2.52648223e-01 8.02710415e-01 -0.32018685 0.42165968 64.75 4.13870731e-01 -9.53594016e-02 4.24714489e-01 -0.22645648 0.17046785 65.00 2.84077200e-01 -1.41350807e-01 3.17300971e-01 -0.46170882 0.10282426 65.25 1.95307973e-01 3.26789798e-03 1.95335311e-01 0.01673046 0.04104366 65.50 2.51699596e-01 1.44548128e-03 2.51703746e-01 0.00574282 0.08023774 65.75 2.02357339e-01 -8.34501394e-02 2.18889055e-01 -0.39114156 0.07226123 66.00 2.26562876e-01 -1.83518272e-02 2.27304919e-01 -0.08082457 0.07963690 66.25 1.75909589e-01 1.39236264e-01 2.24345539e-01 0.66954985 0.08972754 66.50 2.16654798e-01 1.39596407e-01 2.57733309e-01 0.57237641 0.13660068 66.75 1.51900548e-01 2.51838694e-01 2.94102880e-01 1.02805211 0.25180276 67.00 1.35044699e-01 3.05645266e-01 3.34149816e-01 1.15475334 0.30069577 67.25 1.43290040e-01 3.62351624e-01 3.89654636e-01 1.19422306 0.22809930 67.50 2.12816919e-01 3.13347853e-01 3.78784791e-01 0.97418645 0.23080719 67.75 1.97739825e-01 3.92357728e-01 4.39369577e-01 1.10397105 0.31249872 68.00 1.43938500e-01 4.79467597e-01 5.00607099e-01 1.27915160 0.40153631 68.25 -1.86213831e-01 8.42259811e-01 8.62599084e-01 1.78838450 0.36126364 68.50 8.91908033e-02 1.22926405e+00 1.23249548e+00 1.49836699 0.29223095 68.75 1.44183876e+00 2.87800716e-01 1.47028169e+00 0.19701738 0.39981877 69.00 1.40928183e+00 1.43082140e-01 1.41652666e+00 0.10118170 0.53869831 69.25 1.22253134e+00 3.74148381e-02 1.22310374e+00 0.03059485 0.69120668 69.50 1.10564353e+00 -2.15747309e-02 1.10585400e+00 -0.01951080 0.68296527 69.75 1.12364886e+00 -1.05562237e-01 1.12859654e+00 -0.09367100 0.75765073 70.00 1.06965936e+00 -6.42388877e-02 1.07158657e+00 -0.05998342 0.77400929 70.25 1.10800035e+00 -6.71041505e-02 1.11003052e+00 -0.06048941 0.82404649 70.50 1.01836705e+00 -1.45609295e-01 1.02872421e+00 -0.14202051 0.79378173 70.75 9.11628762e-01 -2.24854222e-01 9.38949637e-01 -0.24182427 0.84810879 71.00 8.26169667e-01 -2.73350738e-01 8.70216608e-01 -0.31952753 0.77723028 71.25 6.26042858e-01 -3.10526925e-01 6.98825179e-01 -0.46045488 0.57823402 71.50 3.15453456e-01 -1.44366841e-01 3.46918821e-01 -0.42919629 0.23383277 71.75 1.50591484e-01 3.49965538e-02 1.54604508e-01 0.22834089 0.08466617 72.00 2.46123776e-01 1.61322290e-01 2.94281828e-01 0.58019828 0.21290288 72.25 3.97970332e-01 2.47751465e-01 4.68786917e-01 0.55682659 0.55140861 72.50 3.89136750e-01 2.54307869e-01 4.64865467e-01 0.57884435 0.57229805 72.75 3.77651038e-01 2.82843633e-01 4.71827116e-01 0.64283197 0.66118965 73.00 3.32719113e-01 2.46721267e-01 4.14214186e-01 0.63805836 0.63862343 73.25 3.38950271e-01 2.28521706e-01 4.08790235e-01 0.59320278 0.77884106 73.50 3.07904322e-01 2.17662825e-01 3.77070520e-01 0.61535323 0.71146589 73.75 3.05331345e-01 2.07605922e-01 3.69225472e-01 0.59713323 0.75101197 74.00 2.11854338e-01 2.48894574e-01 3.26849766e-01 0.86561702 0.56565798 74.25 1.09463595e-01 2.78048603e-01 2.98819853e-01 1.19574565 0.56441523 74.50 2.57270230e-02 3.09131102e-01 3.10199803e-01 1.48776401 0.50324152 74.75 -3.01330927e-02 3.67348590e-01 3.68582406e-01 1.65264169 0.62257288 75.00 -5.48454395e-02 3.50830470e-01 3.55091595e-01 1.72587147 0.39670541 75.25 -1.08862027e-01 3.38488277e-01 3.55563292e-01 1.88196121 0.30210978 75.50 -2.93654166e-01 5.13077163e-01 5.91169133e-01 2.09062863 0.28968512 75.75 -4.36618204e-01 8.21711021e-01 9.30507635e-01 2.05921021 0.46755411 76.00 -3.08277418e-01 9.26886225e-01 9.76807576e-01 1.89188194 0.42536451 76.25 -1.88530856e-01 7.99847494e-01 8.21766328e-01 1.80227961 0.32570799 76.50 1.17985880e-02 6.06666833e-01 6.06781553e-01 1.55135056 0.12117619 76.75 5.25233509e-01 6.53268493e-01 8.38230256e-01 0.89361587 0.18742762 77.00 9.80227039e-01 3.21497168e-01 1.03160335e+00 0.31692696 0.50156524 77.25 8.04820474e-01 2.85997408e-01 8.54125583e-01 0.34143791 0.54841621 77.50 1.83698401e-01 4.03186813e-01 4.43062873e-01 1.14328188 0.29837954 77.75 -4.24592873e-02 6.05076589e-01 6.06564481e-01 1.64085325 0.39994453 78.00 -2.73764331e-01 1.14745354e+00 1.17965950e+00 1.80500222 0.55114587 78.25 -2.41066676e-01 1.64612087e+00 1.66367877e+00 1.71620800 0.67173812 78.50 4.26943379e-01 1.98614564e+00 2.03151548e+00 1.35905767 0.66932304 78.75 5.97606477e-01 1.81763075e+00 1.91335178e+00 1.25314646 0.64809788 79.00 1.12130836e+00 1.50156957e+00 1.87404472e+00 0.92937364 0.62171478 79.25 1.07172998e+00 1.25669615e+00 1.65163263e+00 0.86466998 0.63243676 79.50 9.52078867e-01 1.28882876e+00 1.60235256e+00 0.93455596 0.57156723 79.75 9.68240058e-01 1.03904762e+00 1.42024955e+00 0.82065879 0.43013086 80.00 1.08742955e+00 8.34832451e-01 1.37092970e+00 0.65474060 0.53909433 80.25 9.96550793e-01 6.86306006e-01 1.21001216e+00 0.60308914 0.50689295 80.50 1.20026804e+00 7.52929786e-01 1.41687919e+00 0.56025252 0.56784374 80.75 1.09000996e+00 6.78184888e-01 1.28376651e+00 0.55657053 0.44601884 81.00 6.37991089e-01 2.33143266e-01 6.79255778e-01 0.35035727 0.25962743 81.25 3.57882977e-01 1.31382268e-01 3.81236836e-01 0.35183516 0.12271738 81.50 1.70758958e-01 3.37305161e-01 3.78065330e-01 1.10216543 0.11398299 81.75 2.26840163e-01 3.93101066e-01 4.53855602e-01 1.04742051 0.14771176 82.00 3.32655902e-01 4.15730173e-01 5.32439223e-01 0.89595014 0.19752694 82.25 2.28282891e-01 3.23163545e-01 3.95661162e-01 0.95578762 0.10261055 82.50 3.14563167e-01 3.33740802e-01 4.58620659e-01 0.81497078 0.11604204 82.75 1.81544012e-01 3.69312275e-01 4.11521305e-01 1.11391287 0.07918890 83.00 3.19663073e-01 4.82548877e-01 5.78824584e-01 0.98572070 0.11923640 83.25 3.47290017e-01 2.65259204e-01 4.37004349e-01 0.65227311 0.07916284 83.50 4.45944533e-01 3.08517304e-01 5.42263270e-01 0.60522091 0.10842595 83.75 2.76210302e-01 2.39494671e-01 3.65581493e-01 0.71432306 0.05797724 84.00 4.69127506e-01 3.02131081e-01 5.57999827e-01 0.57216526 0.12636555 84.25 4.55765452e-01 1.02599923e-01 4.67171158e-01 0.22142449 0.08638660 84.50 4.38440248e-01 1.41637615e-01 4.60750545e-01 0.31246613 0.07584665 84.75 4.58084574e-01 1.86809152e-01 4.94711164e-01 0.38721661 0.10886503 85.00 6.98060969e-01 1.64020663e-01 7.17071749e-01 0.23077983 0.19415399 85.25 5.61215425e-01 2.57286540e-01 6.17380853e-01 0.42985475 0.18071496 85.50 6.20374487e-01 3.24484340e-01 7.00110414e-01 0.48191390 0.27481192 85.75 6.60382392e-01 1.86524085e-01 6.86218724e-01 0.27527785 0.24566021 86.00 7.71991650e-01 2.47772222e-01 8.10778750e-01 0.31056623 0.29986438 86.25 4.84375152e-01 3.36960145e-01 5.90052054e-01 0.60780689 0.20537585 86.50 4.70246857e-01 4.19438779e-01 6.30127762e-01 0.72835222 0.26606676 86.75 3.48728060e-01 4.59598014e-01 5.76924254e-01 0.92170756 0.21293128 87.00 2.54175084e-01 5.94023853e-01 6.46118651e-01 1.16648291 0.24313002 87.25 -1.16221165e-02 7.78675643e-01 7.78762371e-01 1.58572071 0.18915813 87.50 -1.81356006e-01 9.82443100e-01 9.99041764e-01 1.75333836 0.25878335 87.75 -1.83898558e-01 2.67682998e-01 3.24765865e-01 2.17274493 0.02141186 88.00 1.12863197e-01 1.23530878e-01 1.67325966e-01 0.83049426 0.00492185 88.25 1.28869437e-01 -3.11641405e-01 3.37235373e-01 -1.17869080 0.02188355 88.50 3.82024746e-03 -1.60501019e-01 1.60546477e-01 -1.54699881 0.00498666 88.75 -4.92008767e-02 -7.83546945e-02 9.25212647e-02 -2.13149630 0.00201943 89.00 -6.63607051e-02 -2.42807602e-01 2.51712683e-01 -1.83758669 0.01753847 89.25 -1.09951653e-01 -2.97584977e-01 3.17247828e-01 -1.92471865 0.02912676 89.50 -1.36150484e-01 -4.11953623e-01 4.33869499e-01 -1.88999430 0.06098552 89.75 -2.29931837e-01 -4.97520633e-01 5.48083415e-01 -2.00371256 0.16643914 90.00 -1.03199317e-01 -4.58397314e-01 4.69870404e-01 -1.79223519 0.16947097 90.25 1.28222957e-01 -3.63401737e-01 3.85359507e-01 -1.23159298 0.16555770 90.50 2.78164419e-01 -2.30116234e-01 3.61010977e-01 -0.69114742 0.17949046 90.75 7.30529048e-01 -2.48989759e-01 7.71795692e-01 -0.32848666 0.49366010 91.00 6.68266352e-01 -3.58620465e-01 7.58411864e-01 -0.49253052 0.44602860 91.25 5.99827396e-01 -4.04045543e-01 7.23218989e-01 -0.59278933 0.54280822 91.50 4.96567178e-01 -2.61352569e-01 5.61145371e-01 -0.48448017 0.39054306 91.75 5.31798424e-01 -1.39785685e-03 5.31800261e-01 -0.00262854 0.46544247 92.00 7.46771587e-01 1.02370802e-01 7.53755653e-01 0.13623534 0.65719059 92.25 9.67571780e-01 3.44665094e-02 9.68185463e-01 0.03560660 0.81858664 92.50 9.36169895e-01 -1.31386119e-01 9.45344585e-01 -0.13943362 0.71771322 92.75 9.73672500e-01 -2.39447027e-01 1.00268291e+00 -0.24113643 0.70811216 93.00 8.96745335e-01 -2.21370636e-01 9.23665066e-01 -0.24202128 0.59003440 93.25 9.11339775e-01 -2.74418985e-01 9.51759405e-01 -0.29248033 0.66139944 93.50 7.41278379e-01 -4.26015508e-01 8.54975349e-01 -0.52161166 0.55582889 93.75 5.83540072e-01 -6.45010991e-01 8.69803538e-01 -0.83539177 0.66775255 94.00 3.88405415e-01 -5.13323825e-01 6.43708098e-01 -0.92305409 0.50280555 94.25 3.57494391e-01 -4.39340467e-01 5.66411763e-01 -0.88775319 0.58925837 94.50 4.09489232e-01 -3.00378361e-01 5.07847016e-01 -0.63288580 0.49176141 94.75 4.58896658e-01 -2.57009554e-01 5.25965829e-01 -0.51053382 0.59155577 95.00 4.49779979e-01 -3.25957155e-01 5.55472858e-01 -0.62711386 0.51963518 95.25 4.78652558e-01 -3.31029931e-01 5.81970005e-01 -0.60505737 0.59479075 95.50 4.26289089e-01 -2.40770732e-01 4.89584449e-01 -0.51413965 0.46585412 95.75 4.06821813e-01 -1.90425652e-01 4.49183611e-01 -0.43778812 0.44476160 96.00 4.08094973e-01 -2.12062029e-01 4.59904132e-01 -0.47923502 0.46579776 96.25 4.01202792e-01 -2.55204445e-01 4.75492365e-01 -0.56654039 0.51073603 96.50 4.12780803e-01 -4.77827870e-01 6.31432866e-01 -0.85830535 0.54600267 96.75 2.96713729e-01 -5.16616283e-01 5.95761212e-01 -1.04945771 0.59451897 97.00 4.74700123e-02 -4.53430788e-01 4.55908852e-01 -1.46648555 0.48743221 97.25 -3.05793096e-02 -3.98175299e-01 3.99347797e-01 -1.64744448 0.47867035 97.50 -1.69297973e-01 -3.30243789e-01 3.71110177e-01 -2.04450904 0.50968697 97.75 -2.20117827e-01 -2.72021820e-01 3.49925318e-01 -2.25111695 0.52268211 98.00 -3.21158369e-01 -2.29820014e-01 3.94917633e-01 -2.52047532 0.55340724 98.25 -4.32834857e-01 -2.26737812e-01 4.88626697e-01 -2.65905254 0.60413804 98.50 -6.90511400e-01 2.50201728e-02 6.90964545e-01 3.10537423 0.74496056 98.75 -7.93081526e-01 1.46307301e-01 8.06463969e-01 2.95916419 0.78154011 99.00 -9.75759793e-01 3.71549928e-01 1.04410561e+00 2.77776414 0.81210218 99.25 -1.11097385e+00 5.29845910e-01 1.23085319e+00 2.69657874 0.78490364 99.50 -1.60815370e+00 1.04066712e+00 1.91550160e+00 2.56724528 0.86452594 99.75 -1.64152105e+00 1.52237609e+00 2.23879886e+00 2.39383436 0.79362962 100.00 -1.36225735e+00 3.09265095e+00 3.37938381e+00 1.98570702 0.87228226 100.25 -7.01422394e-01 3.83454778e+00 3.89817266e+00 1.75171792 0.87236989 100.50 1.16083234e+00 4.02333574e+00 4.18745295e+00 1.28990016 0.92426816 100.75 1.68146946e+00 3.36541994e+00 3.76209927e+00 1.10744365 0.89548022 101.00 2.42687403e+00 2.12005880e+00 3.22247838e+00 0.71802289 0.94354907 101.25 2.40273205e+00 1.71159363e+00 2.95002950e+00 0.61896861 0.93480542 101.50 2.40972742e+00 1.22143641e+00 2.70160936e+00 0.46913439 0.96128058 101.75 2.38849517e+00 1.03215238e+00 2.60196996e+00 0.40789851 0.96188963 102.00 2.36442008e+00 7.87662848e-01 2.49216674e+00 0.32156891 0.95908874 102.25 2.26842265e+00 6.22493094e-01 2.35228377e+00 0.26782386 0.95496021 102.50 2.08879485e+00 4.71884708e-01 2.14143389e+00 0.22218273 0.97443194 102.75 1.96119058e+00 4.01906675e-01 2.00194842e+00 0.20213136 0.96993591 103.00 1.87244864e+00 4.27097203e-01 1.92054053e+00 0.22425887 0.98248111 103.25 1.87535798e+00 3.86422015e-01 1.91475573e+00 0.20320835 0.98054873 103.50 1.88168499e+00 3.12405507e-01 1.90744216e+00 0.16452365 0.98660194 103.75 1.87781427e+00 2.67686952e-01 1.89679802e+00 0.14159840 0.98237113 104.00 1.86200671e+00 2.28610275e-01 1.87598817e+00 0.12216490 0.98740688 104.25 1.86344687e+00 2.16371516e-01 1.87596665e+00 0.11559595 0.98389921 104.50 1.92946968e+00 2.22125100e-01 1.94221337e+00 0.11461779 0.98055582 104.75 2.05993615e+00 1.34700628e-02 2.05998020e+00 0.00653897 0.97249197 105.00 2.05990520e+00 -1.98616314e-01 2.06945836e+00 -0.09612298 0.98047176 105.25 1.87844551e+00 -2.91145464e-01 1.90087433e+00 -0.15376923 0.97668675 105.50 1.77729156e+00 -3.49935924e-01 1.81141394e+00 -0.19440610 0.98453868 105.75 1.64953490e+00 -3.19729717e-01 1.68023584e+00 -0.19145610 0.98326238 106.00 1.61044995e+00 -2.89994978e-01 1.63635147e+00 -0.17816150 0.98753019 106.25 1.68642289e+00 -2.05913136e-01 1.69894744e+00 -0.12149912 0.98441521 106.50 1.77190574e+00 -1.38445581e-01 1.77730614e+00 -0.07797530 0.98638118 106.75 1.97704117e+00 -2.54279723e-01 1.99332636e+00 -0.12791406 0.97239317 107.00 2.13217519e+00 -4.45661296e-01 2.17825274e+00 -0.20605072 0.96261516 107.25 1.96223753e+00 -8.21124136e-01 2.12711565e+00 -0.39632089 0.93978638 107.50 1.85017318e+00 -9.27325659e-01 2.06955882e+00 -0.46461529 0.96718022 107.75 1.87491451e+00 -1.02743064e+00 2.13797057e+00 -0.50129717 0.96774461 108.00 1.88337483e+00 -1.18376793e+00 2.22450157e+00 -0.56113766 0.95755818 108.25 1.69065655e+00 -1.57897911e+00 2.31332977e+00 -0.75125551 0.92548234 108.50 1.42365005e+00 -1.77020304e+00 2.27165100e+00 -0.89348155 0.89122676 108.75 8.38815476e-01 -1.90288596e+00 2.07956399e+00 -1.15560914 0.85825091 109.00 5.17683636e-01 -1.91245684e+00 1.98128431e+00 -1.30644115 0.88455570 109.25 4.07410024e-01 -1.80910902e+00 1.85441591e+00 -1.34929223 0.91017783 109.50 1.99097689e-01 -1.79608748e+00 1.80708885e+00 -1.46039627 0.90122078 109.75 -2.37647467e-01 -1.37674319e+00 1.39710348e+00 -1.74172759 0.77908518 110.00 -1.19932925e-01 -9.93164116e-01 1.00037936e+00 -1.69097283 0.47613354 110.25 -1.02236551e-01 -1.55500707e+00 1.55836431e+00 -1.63644852 0.39834381 110.50 -9.32432059e-01 -1.34079473e+00 1.63314422e+00 -2.17845019 0.53141822 110.75 -1.09553406e+00 -5.92381950e-01 1.24543617e+00 -2.64589874 0.79460917 111.00 -9.95077955e-01 -4.49070589e-01 1.09171632e+00 -2.71766493 0.72421361 111.25 -7.35479797e-01 -4.04320784e-02 7.36590310e-01 -3.08667419 0.44944167 111.50 -5.06100511e-01 9.49620395e-02 5.14932536e-01 2.95611454 0.29337166 111.75 -3.54180079e-01 1.59940450e-01 3.88618677e-01 2.71742602 0.21840356 112.00 -1.36806587e-01 2.04869411e-01 2.46348367e-01 2.15956556 0.11553734 112.25 -3.82662124e-02 3.02410469e-01 3.04821907e-01 1.69666471 0.28306207 112.50 -9.67057979e-03 3.11784884e-01 3.11934824e-01 1.60180322 0.31357932 112.75 -6.39466577e-02 4.68874412e-01 4.73214950e-01 1.70634338 0.57443891 113.00 1.21612705e-01 4.69569747e-01 4.85062261e-01 1.31737687 0.57617529 113.25 3.23070030e-01 4.07881540e-01 5.20328353e-01 0.90091055 0.74372105 113.50 3.62872029e-01 3.48392271e-01 5.03044018e-01 0.76504320 0.75567816 113.75 3.22588605e-01 3.27311886e-01 4.59561181e-01 0.79266573 0.79932224 114.00 2.95159733e-01 2.41732397e-01 3.81515163e-01 0.68621247 0.67211748 114.25 2.91351865e-01 2.16792449e-01 3.63159572e-01 0.63970894 0.76743966 114.50 2.78691122e-01 2.53224778e-01 3.76552161e-01 0.73755806 0.67155856 114.75 2.55193297e-01 2.89603379e-01 3.85997067e-01 0.84847570 0.62764112 115.00 2.45047313e-01 3.73892994e-01 4.47039323e-01 0.99063837 0.54945749 115.25 2.16738847e-01 5.22543667e-01 5.65709830e-01 1.17761682 0.68326065 115.50 3.36519069e-01 6.36865575e-01 7.20307465e-01 1.08468856 0.71864795 115.75 4.87695309e-01 7.66118709e-01 9.08176520e-01 1.00391363 0.77268835 116.00 9.79254612e-01 7.34483749e-01 1.22409394e+00 0.64352907 0.83550848 116.25 1.19416785e+00 5.90624261e-01 1.33224392e+00 0.45931078 0.88312030 116.50 1.31529880e+00 2.10881475e-01 1.33209681e+00 0.15897673 0.83894776 116.75 1.35192174e+00 -1.75515866e-01 1.36326748e+00 -0.12910482 0.87321041 117.00 7.00367171e-01 -6.24234477e-01 9.38180610e-01 -0.72798541 0.53994661 117.25 3.55085048e-01 -3.90417470e-01 5.27741597e-01 -0.83275683 0.28737289 117.50 6.10491622e-01 1.84247868e-01 6.37689029e-01 0.29310960 0.50108074 117.75 9.25600797e-01 2.67139362e-01 9.63379611e-01 0.28097649 0.67991361 118.00 1.46237498e+00 -9.18614758e-02 1.46525736e+00 -0.06273421 0.81641281 118.25 1.67644517e+00 -3.82914768e-01 1.71961976e+00 -0.22455657 0.84825440 118.50 1.44650983e+00 -1.38068156e+00 1.99966803e+00 -0.76211839 0.81043040 118.75 9.57532198e-01 -1.64991454e+00 1.90763883e+00 -1.04494873 0.80518121 119.00 -2.32987316e-01 -1.19722467e+00 1.21968438e+00 -1.76300018 0.73186478 119.25 -3.40558673e-01 -9.77678749e-01 1.03529510e+00 -1.90598612 0.78945849 119.50 -2.89905946e-01 -6.10932211e-01 6.76227494e-01 -2.01386149 0.69010002 119.75 -3.02030332e-01 -5.18885112e-01 6.00386610e-01 -2.09793180 0.69595523 120.00 -2.36977654e-01 -4.39012595e-01 4.98889234e-01 -2.06577236 0.57115351 120.25 -2.32177220e-01 -4.51950324e-01 5.08099751e-01 -2.04536187 0.51865266 120.50 -2.95713100e-01 -4.72664898e-01 5.57546719e-01 -2.12984818 0.60305041 120.75 -3.56196919e-01 -4.95666680e-01 6.10378328e-01 -2.19391117 0.56721348 121.00 -5.95055205e-01 -4.01126061e-01 7.17629998e-01 -2.54846229 0.61411207 121.25 -7.80920093e-01 -3.12526132e-01 8.41135409e-01 -2.76091177 0.63328145 121.50 -1.07989124e+00 -2.11495726e-01 1.10040699e+00 -2.94819151 0.83686616 121.75 -1.26097082e+00 -1.05747543e-01 1.26539715e+00 -3.05792642 0.83176625 122.00 -1.40092133e+00 3.60941982e-01 1.44667194e+00 2.88943067 0.83094275 122.25 -1.41489630e+00 7.39901568e-01 1.59667964e+00 2.65976430 0.72101104 122.50 -1.54604319e+00 1.82005264e+00 2.38806222e+00 2.27497083 0.78932515 122.75 -8.57744313e-01 2.48573625e+00 2.62956461e+00 1.90306930 0.65478132 123.00 1.11600605e+00 4.23960408e+00 4.38402923e+00 1.31340185 0.81108807 123.25 2.71749929e+00 3.60921576e+00 4.51788012e+00 0.92542045 0.79867484 123.50 3.48893979e+00 7.75732446e-01 3.57413790e+00 0.21878161 0.68974713 123.75 2.10352793e+00 2.74470710e-02 2.10370699e+00 0.01304737 0.63053806 124.00 1.26689254e+00 -3.94581145e-02 1.26750687e+00 -0.03113552 0.74839857 124.25 1.14154801e+00 -4.50637109e-03 1.14155690e+00 -0.00394758 0.72517982 124.50 1.18977150e+00 2.79077473e-01 1.22206402e+00 0.23039867 0.84887365 124.75 1.40846807e+00 2.11730950e-01 1.42429361e+00 0.14920986 0.87021911 125.00 1.58034580e+00 -5.61051923e-02 1.58134141e+00 -0.03548694 0.91188638 125.25 1.40265569e+00 -3.33055208e-01 1.44165487e+00 -0.23312883 0.89154492 125.50 1.31423528e+00 -5.63438776e-01 1.42992224e+00 -0.40501719 0.93550777 125.75 1.23350410e+00 -6.85734630e-01 1.41129882e+00 -0.50738007 0.93948408 126.00 1.14762881e+00 -7.69130438e-01 1.38152579e+00 -0.59043852 0.94524220 126.25 9.33717199e-01 -9.34686493e-01 1.32116110e+00 -0.78591695 0.91952969 126.50 7.47998189e-01 -1.05590776e+00 1.29400251e+00 -0.95445933 0.92562753 126.75 4.47615431e-01 -1.12677488e+00 1.21242782e+00 -1.19265974 0.87239125 127.00 2.80388108e-01 -9.07744345e-01 9.50061728e-01 -1.27120873 0.78745901 127.25 3.55799908e-01 -5.59415616e-01 6.62977682e-01 -1.00431124 0.63908742 127.50 5.05652267e-01 -5.45103694e-01 7.43520176e-01 -0.82292629 0.70131657 127.75 5.11799011e-01 -8.28791837e-01 9.74081176e-01 -1.01759094 0.78380253 128.00 3.93091704e-01 -9.61034788e-01 1.03832025e+00 -1.18253010 0.83311351 128.25 1.13744286e-01 -1.01903327e+00 1.02536168e+00 -1.45963665 0.83818796 128.50 -1.05083549e-02 -1.00437231e+00 1.00442728e+00 -1.58125855 0.87126388 128.75 -1.01527502e-01 -1.02898124e+00 1.03397787e+00 -1.66914598 0.84509498 129.00 -1.61369499e-01 -9.76578185e-01 9.89820725e-01 -1.73455630 0.80046961 129.25 -2.72857041e-01 -8.27172745e-01 8.71014187e-01 -1.88942400 0.78584062 129.50 -2.34457654e-01 -8.20473426e-01 8.53315320e-01 -1.84913731 0.77672865 129.75 -1.35193094e-01 -9.87488833e-01 9.96700240e-01 -1.70685641 0.78340833 130.00 -1.95441965e-01 -1.21421807e+00 1.22984677e+00 -1.73038863 0.84559222 130.25 -6.66783435e-01 -1.54873827e+00 1.68617626e+00 -1.97734440 0.89817591 130.50 -9.73382846e-01 -1.38708414e+00 1.69454318e+00 -2.18269415 0.86499968 130.75 -1.74645177e+00 -8.14504546e-01 1.92704734e+00 -2.70520357 0.89310083 131.00 -1.80224672e+00 -4.31261986e-01 1.85312712e+00 -2.90671787 0.88812484 131.25 -1.32006749e+00 2.33220680e-01 1.34051112e+00 2.96672387 0.82331842 131.50 -1.09114479e+00 1.52610098e-01 1.10176531e+00 3.00263170 0.80817310 131.75 -1.01395611e+00 -2.85213472e-02 1.01435716e+00 -3.11347129 0.81063591 132.00 -1.16019428e+00 -8.31807263e-02 1.16317230e+00 -3.07001961 0.78899472 132.25 -1.50358239e+00 -3.90078894e-02 1.50408830e+00 -3.11565517 0.81873891 132.50 -1.57857013e+00 2.50495157e-01 1.59832146e+00 2.98421998 0.78675097 132.75 -1.26610290e+00 3.86889163e-01 1.32389568e+00 2.84502923 0.77289640 133.00 -1.40529051e+00 4.61401980e-01 1.47909878e+00 2.82434994 0.80802571 133.25 -1.58913215e+00 7.36729267e-01 1.75160241e+00 2.70748276 0.88763788 133.50 -1.58059217e+00 8.79501829e-01 1.80881041e+00 2.63381995 0.85150220 133.75 -1.67811909e+00 1.20616153e+00 2.06661785e+00 2.51838805 0.86189856 134.00 -1.64906692e+00 1.81680938e+00 2.45361326e+00 2.30783394 0.74040105 134.25 -1.25913685e+00 3.12396453e+00 3.36817161e+00 1.95393556 0.86336344 134.50 -2.52290062e-01 3.39163648e+00 3.40100695e+00 1.64504552 0.87097809 134.75 6.12348884e-01 3.46698897e+00 3.52065103e+00 1.39597663 0.93047424 135.00 1.50645893e+00 3.18895198e+00 3.52687301e+00 1.12947200 0.90452918 135.25 2.37868004e+00 2.62876717e+00 3.54521305e+00 0.83529974 0.92046709 135.50 3.00416663e+00 1.75738955e+00 3.48043606e+00 0.52930518 0.89781334 135.75 3.47396216e+00 7.67707094e-01 3.55777842e+00 0.21749336 0.92388356 136.00 3.16920543e+00 4.00992169e-02 3.16945910e+00 0.01265209 0.94305932 136.25 2.91942488e+00 -3.98292977e-01 2.94646889e+00 -0.13559147 0.95852733 136.50 2.95466231e+00 -8.88651611e-01 3.08540614e+00 -0.29215618 0.94532345 136.75 2.95757150e+00 -1.26821358e+00 3.21801101e+00 -0.40508685 0.95681654 137.00 3.04174205e+00 -1.97292447e+00 3.62555178e+00 -0.57540211 0.94030681 137.25 3.13925650e+00 -2.54611801e+00 4.04198568e+00 -0.68144714 0.94226196 137.50 2.95669055e+00 -3.54251600e+00 4.61426469e+00 -0.87529322 0.91407017 137.75 2.77297286e+00 -4.43812705e+00 5.23319694e+00 -1.01233581 0.89055999 138.00 1.74124530e+00 -6.29097745e+00 6.52750584e+00 -1.30077180 0.81303273 138.25 4.73523517e-02 -7.61241603e+00 7.61256330e+00 -1.56457600 0.83387320 138.50 -3.68823480e+00 -7.49126882e+00 8.34998111e+00 -2.02829541 0.77980315 138.75 -6.21445186e+00 -7.21262931e+00 9.52057948e+00 -2.28199037 0.83704187 139.00 -8.27904990e+00 -3.69184894e+00 9.06490021e+00 -2.72213129 0.82278456 139.25 -8.59394461e+00 -2.73254357e+00 9.01790876e+00 -2.83373994 0.89703067 139.50 -9.68300245e+00 -1.74104645e+00 9.83828132e+00 -2.96368918 0.89446238 139.75 -1.02298269e+01 -7.36643155e-01 1.02563152e+01 -3.06970739 0.90224354 140.00 -9.17043343e+00 1.97967021e+00 9.38168127e+00 2.92898000 0.87763343 140.25 -8.94661301e+00 3.88925647e+00 9.75541902e+00 2.73151939 0.88632165 140.50 -8.30157917e+00 7.07561890e+00 1.09078229e+01 2.43575207 0.93502544 140.75 -7.35146109e+00 8.39106015e+00 1.11558895e+01 2.29025259 0.91323308 141.00 -2.44734078e+00 1.09723513e+01 1.12419736e+01 1.79025030 0.90652754 141.25 -2.80775834e-01 1.04243649e+01 1.04281455e+01 1.59772439 0.90866507 141.50 2.93150123e+00 7.05807525e+00 7.64265175e+00 1.17713612 0.83896669 141.75 2.95626752e+00 5.01842076e+00 5.82443684e+00 1.03844253 0.75676264 142.00 1.61846157e+00 2.07977114e+00 2.63531134e+00 0.90949502 0.52794994 142.25 1.02910718e+00 1.35460048e+00 1.70117725e+00 0.92110802 0.47472467 142.50 2.65966012e-01 6.35234268e-01 6.88665735e-01 1.17428272 0.18512741 142.75 -1.63246025e-01 4.03120241e-01 4.34919755e-01 1.95556794 0.07943240 143.00 -1.18839112e+00 7.03579211e-01 1.38104930e+00 2.60704408 0.48403213 143.25 -1.56792861e+00 7.69333696e-01 1.74650350e+00 2.68543781 0.60929467 143.50 -2.06606312e+00 9.42141178e-01 2.27073706e+00 2.71375377 0.76113781 143.75 -2.49991604e+00 1.13217376e+00 2.74433920e+00 2.71634239 0.83762111 144.00 -2.96935451e+00 1.16946050e+00 3.19134831e+00 2.76640498 0.87167837 144.25 -3.31774222e+00 1.38112214e+00 3.59373229e+00 2.74712786 0.84499674 144.50 -3.72059020e+00 1.72742017e+00 4.10204484e+00 2.70692171 0.88016831 144.75 -4.30980676e+00 2.10459545e+00 4.79622313e+00 2.68732689 0.84520679 145.00 -5.52404664e+00 2.74918298e+00 6.17034021e+00 2.67980633 0.90253994 145.25 -6.13725873e+00 3.90919005e+00 7.27651782e+00 2.57443888 0.89659257 145.50 -7.05510073e+00 4.44946479e+00 8.34099414e+00 2.57892395 0.91971238 145.75 -7.70233699e+00 5.98029311e+00 9.75140507e+00 2.48139243 0.86427776 146.00 -8.03204639e+00 9.46919459e+00 1.24169004e+01 2.27426139 0.89446581 146.25 -6.89392765e+00 1.25751192e+01 1.43408459e+01 2.07227165 0.88337200 146.50 -4.15742074e+00 1.49777795e+01 1.55440673e+01 1.84155266 0.89626276 146.75 -1.91601269e-01 1.71405745e+01 1.71416454e+01 1.58197409 0.88995370 147.00 4.27412101e+00 1.71626858e+01 1.76868848e+01 1.32672547 0.88488168 147.25 8.40724215e+00 1.33453241e+01 1.57727422e+01 1.00862632 0.85068177 147.50 1.02441501e+01 9.92612128e+00 1.42643084e+01 0.76963226 0.84626681 147.75 1.00503829e+01 6.28762820e+00 1.18551451e+01 0.55903843 0.85845355 148.00 9.33159417e+00 4.81044208e+00 1.04985238e+01 0.47597103 0.88114312 148.25 7.92102016e+00 2.43894735e+00 8.28800486e+00 0.29869617 0.81712150 148.50 6.85329229e+00 1.64083829e+00 7.04698272e+00 0.23499968 0.84965237 148.75 5.75085048e+00 1.77939459e+00 6.01984438e+00 0.30007111 0.79006628 149.00 5.16665471e+00 1.45320476e+00 5.36713377e+00 0.27418236 0.75999882 149.25 4.64581792e+00 1.06115637e+00 4.76546713e+00 0.22455879 0.71572489 149.50 4.35615440e+00 9.31815654e-01 4.45470106e+00 0.21073204 0.77960271 149.75 4.21015854e+00 9.05811649e-01 4.30649854e+00 0.21191863 0.77897361 150.00 4.03067155e+00 1.03671536e+00 4.16186158e+00 0.25174977 0.77912377 150.25 3.71167123e+00 1.09624446e+00 3.87017509e+00 0.28718588 0.80196880 150.50 3.37326963e+00 1.05160002e+00 3.53338515e+00 0.30219691 0.78518413 150.75 3.03638947e+00 1.15219957e+00 3.24764913e+00 0.36267829 0.79695551 151.00 2.81900335e+00 1.00171091e+00 2.99168926e+00 0.34142609 0.78756718 151.25 2.91621775e+00 8.55189517e-01 3.03902535e+00 0.28525542 0.81826589 151.50 2.62172414e+00 1.03566963e+00 2.81887372e+00 0.37621785 0.81342819 151.75 2.27227453e+00 1.03461638e+00 2.49673038e+00 0.42727080 0.79341441 152.00 1.96513390e+00 1.17004389e+00 2.28708416e+00 0.53703147 0.73229107 152.25 1.68212910e+00 1.12540429e+00 2.02388071e+00 0.58964086 0.50067124 152.50 1.72376221e+00 9.22227207e-01 1.95495759e+00 0.49126051 0.42504938 152.75 1.60485500e+00 8.29863554e-01 1.80671887e+00 0.47723041 0.38681444 153.00 1.21893691e+00 1.00532405e+00 1.58002647e+00 0.68965412 0.29777382 153.25 7.13756650e-01 1.46572767e+00 1.63027794e+00 1.11763178 0.33928852 153.50 1.05626161e+00 1.86235583e+00 2.14104129e+00 1.05487078 0.49691250 153.75 9.61103771e-01 2.04056531e+00 2.25557692e+00 1.13061769 0.59265793 154.00 9.69763143e-01 2.14638007e+00 2.35528936e+00 1.14643545 0.72196585 154.25 9.21553477e-01 2.60405650e+00 2.76231263e+00 1.23065890 0.71858344 154.50 4.81203984e-01 2.78965476e+00 2.83085340e+00 1.39998139 0.67067424 154.75 6.59713077e-01 3.06757679e+00 3.13771393e+00 1.35896281 0.61946951 155.00 1.02645915e+00 3.28274952e+00 3.43948584e+00 1.26774497 0.58845332 155.25 1.37660460e+00 3.17008432e+00 3.45607795e+00 1.16111821 0.61929029 155.50 1.64364831e+00 3.13798548e+00 3.54239080e+00 1.08829763 0.62926210 155.75 2.22666446e+00 3.50208846e+00 4.15001906e+00 1.00446094 0.77062380 156.00 2.05951765e+00 3.41307238e+00 3.98631108e+00 1.02786559 0.75010573 156.25 1.61661332e+00 3.60447491e+00 3.95040225e+00 1.14918904 0.72056065 156.50 2.07936308e+00 3.66274776e+00 4.21182526e+00 1.05446113 0.58673336 156.75 3.37163428e+00 2.66638182e+00 4.29854740e+00 0.66912300 0.62466451 157.00 3.51442156e+00 2.51144771e+00 4.31955189e+00 0.62046549 0.68984622 157.25 3.97567793e+00 2.53363246e+00 4.71437254e+00 0.56738341 0.79163087 157.50 4.07834369e+00 2.32514586e+00 4.69459163e+00 0.51815920 0.77188998 157.75 3.88752444e+00 2.31191235e+00 4.52302830e+00 0.53651363 0.76030554 158.00 3.64838698e+00 2.31784301e+00 4.32239792e+00 0.56597624 0.76035098 158.25 3.77599103e+00 2.22619553e+00 4.38338395e+00 0.53271204 0.78295077 158.50 3.40114508e+00 2.26067642e+00 4.08392528e+00 0.58662663 0.72108754 158.75 3.50994828e+00 2.31708419e+00 4.20578365e+00 0.58347587 0.78592296 159.00 2.94150514e+00 1.89279673e+00 3.49787535e+00 0.57177736 0.72079813 159.25 2.54625151e+00 1.54417165e+00 2.97789571e+00 0.54514791 0.71799406 159.50 2.40796225e+00 1.46054422e+00 2.81628685e+00 0.54522016 0.74057593 159.75 2.23127444e+00 1.34313608e+00 2.60434256e+00 0.54185881 0.75996743 160.00 1.28769384e+00 1.54172447e+00 2.00874831e+00 0.87494002 0.70713863 160.25 8.16123782e-01 1.83395709e+00 2.00735065e+00 1.15210231 0.74544902 160.50 3.54952498e-01 2.35993923e+00 2.38648369e+00 1.42150790 0.79662342 160.75 1.79537809e-02 2.46973006e+00 2.46979532e+00 1.56352692 0.83270304 161.00 -3.67854712e-01 2.47409357e+00 2.50129088e+00 1.71839763 0.83142433 161.25 -6.20303773e-01 2.45631265e+00 2.53342626e+00 1.81815901 0.82884209 161.50 -1.25068308e+00 2.54415747e+00 2.83495069e+00 2.02769355 0.82152147 161.75 -1.90463995e+00 2.27422131e+00 2.96643488e+00 2.26798331 0.77036407 162.00 -2.65336626e+00 1.72518560e+00 3.16490408e+00 2.56508563 0.79018678 162.25 -3.18278334e+00 1.59831056e+00 3.56155955e+00 2.67620748 0.72981472 162.50 -4.62941635e+00 1.48145187e+00 4.86067849e+00 2.83188214 0.77587707 162.75 -5.23214349e+00 1.58156538e+00 5.46595596e+00 2.84804665 0.73570605 163.00 -6.34248556e+00 2.26767769e+00 6.73568743e+00 2.79821858 0.67856382 163.25 -6.00111815e+00 3.19104717e+00 6.79677873e+00 2.65287499 0.60524162 163.50 -3.87110569e+00 4.95084861e+00 6.28461305e+00 2.23440749 0.53067372 163.75 -2.19119975e+00 5.42273211e+00 5.84870754e+00 1.95481216 0.48665184 164.00 -1.64765365e+00 4.66055056e+00 4.94322709e+00 1.91061420 0.61044337 164.25 -1.01677242e+00 3.29082967e+00 3.44432665e+00 1.87046335 0.53430751 164.50 -4.19141168e-01 2.61331578e+00 2.64671469e+00 1.72982864 0.65456722 164.75 -3.18118473e-01 2.16679038e+00 2.19001825e+00 1.71657043 0.62022669 165.00 -9.02105190e-01 1.65988611e+00 1.88918386e+00 2.06861548 0.72739899 165.25 -8.86814694e-01 1.46661854e+00 1.71388747e+00 2.11463981 0.68943610 165.50 -8.84803097e-01 1.11011651e+00 1.41958980e+00 2.24372749 0.71563094 165.75 -9.95074118e-01 7.99483128e-01 1.27645829e+00 2.46475719 0.65758965 166.00 -9.00709945e-01 5.15417606e-01 1.03775417e+00 2.62183895 0.72517635 166.25 -8.21190711e-01 3.45434750e-01 8.90886833e-01 2.74341135 0.61370788 166.50 -7.32233759e-01 1.75094839e-01 7.52877467e-01 2.90687590 0.58386432 166.75 -6.40324583e-01 -4.32099899e-02 6.41780862e-01 -3.07421342 0.46832789 167.00 -5.34182272e-01 -3.07549401e-01 6.16390569e-01 -2.61920341 0.44102340 167.25 -7.24440652e-01 -5.65565378e-01 9.19063902e-01 -2.47873596 0.46540425 167.50 -9.04944395e-01 -7.90482411e-01 1.20157680e+00 -2.42360439 0.51750299 167.75 -1.36008612e+00 -6.00392473e-01 1.48670958e+00 -2.72588241 0.44247937 168.00 -1.79522933e+00 -2.83696980e-01 1.81750717e+00 -2.98486050 0.62793754 168.25 -1.59002689e+00 2.51628522e-01 1.60981441e+00 2.98464002 0.69205642 168.50 -1.36210776e+00 2.97386438e-01 1.39419376e+00 2.92663760 0.72675358 168.75 -1.00083218e+00 -5.74307068e-02 1.00247859e+00 -3.08427256 0.62125119 169.00 -8.76523208e-01 -1.62660967e-01 8.91488376e-01 -2.95810478 0.69059903 169.25 -8.94712106e-01 -1.98659660e-01 9.16501726e-01 -2.92309972 0.53226621 169.50 -8.95776885e-01 1.79493618e-02 8.95956699e-01 3.12155758 0.49517608 169.75 -5.81373194e-01 2.64016188e-01 6.38513381e-01 2.71531355 0.47531598 170.00 -4.44931394e-01 2.96729528e-01 5.34801233e-01 2.55342109 0.52165888 170.25 -1.61708775e-01 4.04831544e-02 1.66699171e-01 2.89628831 0.11953748 170.50 -6.37786012e-02 -1.09608632e-01 1.26813888e-01 -2.09778254 0.09856756 170.75 -8.69232695e-03 -3.41672454e-01 3.41783005e-01 -1.59623137 0.51989136 171.00 3.96741875e-02 -3.92567602e-01 3.94567311e-01 -1.47007499 0.62898369 171.25 8.96555054e-02 -5.44110585e-01 5.51447584e-01 -1.40748932 0.60243874 171.50 1.73262391e-01 -6.07145923e-01 6.31384216e-01 -1.29281323 0.56588918 171.75 2.92294124e-01 -6.95424724e-01 7.54354957e-01 -1.17290466 0.45516198 172.00 4.30917847e-01 -7.37003073e-01 8.53735158e-01 -1.04171073 0.43272066 172.25 4.78781167e-01 -5.55583652e-01 7.33419798e-01 -0.85951303 0.14725347 172.50 -7.03519808e-02 2.00107658e-01 2.12114299e-01 1.90886971 0.00959121 172.75 -8.11363243e-01 1.73172335e-01 8.29637854e-01 2.93131398 0.29250541 173.00 -8.86231050e-01 -8.77386053e-02 8.90563606e-01 -3.04291226 0.37181481 173.25 -8.82546979e-01 -3.38780862e-01 9.45336788e-01 -2.77507073 0.46431477 173.50 -8.23232527e-01 -4.74563139e-01 9.50222061e-01 -2.61865954 0.44403402 173.75 -4.60573758e-01 -6.71587906e-01 8.14345444e-01 -2.17192714 0.36009633 174.00 -1.15786667e-01 -3.00928679e-01 3.22435454e-01 -1.93810004 0.04872821 174.25 -6.72642601e-03 7.69225921e-01 7.69255330e-01 1.57954051 0.32734022 174.50 -3.35529009e-01 5.90023025e-01 6.78753921e-01 2.08786122 0.44528105 174.75 -6.76075435e-01 2.40043362e-01 7.17425125e-01 2.80042240 0.64027000 175.00 -7.27108178e-01 1.82406332e-01 7.49638828e-01 2.89579960 0.66733369 175.25 -6.93704835e-01 1.47003174e-01 7.09109534e-01 2.93277159 0.68965702 175.50 -7.09050014e-01 3.96195708e-02 7.10156062e-01 3.08577372 0.64371591 175.75 -7.28246502e-01 2.04863498e-02 7.28534597e-01 3.11346901 0.70641788 176.00 -7.08341959e-01 8.18401268e-02 7.13054092e-01 3.02656508 0.69888429 176.25 -6.96528781e-01 9.89236342e-02 7.03518463e-01 3.00051241 0.76855456 176.50 -5.31286662e-01 1.98669294e-02 5.31657984e-01 3.10421608 0.62767978 176.75 -4.70747376e-01 -4.99507046e-02 4.73390076e-01 -3.03587886 0.76926954 177.00 -4.17962387e-01 -8.47287043e-02 4.26463962e-01 -2.94158453 0.69495953 177.25 -3.95049123e-01 -1.47644428e-01 4.21737699e-01 -2.78392983 0.73125304 177.50 -4.25644819e-01 -1.72772918e-01 4.59373479e-01 -2.75600301 0.72432759 177.75 -4.67046945e-01 -1.89708144e-01 5.04105177e-01 -2.75576453 0.79171851 178.00 -4.41554142e-01 -2.02187105e-01 4.85643579e-01 -2.71218954 0.69801597 178.25 -4.32703979e-01 -2.40034698e-01 4.94822584e-01 -2.63512377 0.76244607 178.50 -5.05719986e-01 -2.85871371e-01 5.80926110e-01 -2.62709692 0.63940119 178.75 -6.85032681e-01 -3.14062235e-01 7.53594626e-01 -2.71172311 0.65285707 179.00 -6.64280265e-01 1.98575559e-02 6.64577003e-01 3.11170821 0.50669498 179.25 -5.13910669e-01 3.13943637e-01 6.02216558e-01 2.59320320 0.52453044 179.50 -2.74685919e-01 2.87932422e-01 3.97941495e-01 2.33265445 0.34929543 179.75 -1.27344270e-01 1.82787220e-01 2.22772824e-01 2.17929088 0.17622646 180.00 3.40853866e-03 -3.94835581e-02 3.96304112e-02 -1.48468178 0.00520800 180.25 5.08937440e-02 -1.57144280e-01 1.65180199e-01 -1.25759012 0.09866368 180.50 1.03841012e-01 -3.48289484e-01 3.63439844e-01 -1.28104159 0.26089594 180.75 2.47592311e-02 -4.80063893e-01 4.80701946e-01 -1.51926712 0.42985166 181.00 -1.88368444e-01 -5.98417575e-01 6.27364539e-01 -1.87575481 0.54143913 181.25 -2.67593225e-01 -5.81246521e-01 6.39885655e-01 -2.00224717 0.59308682 181.50 -3.15237754e-01 -4.93816172e-01 5.85857708e-01 -2.13895277 0.59361449 181.75 -2.71205732e-01 -5.15922240e-01 5.82862168e-01 -2.05476976 0.58073443 182.00 -3.14180597e-01 -6.54363902e-01 7.25879855e-01 -2.01842302 0.58067949 182.25 -3.63105507e-01 -7.08240438e-01 7.95895802e-01 -2.04454177 0.61889550 182.50 -4.87580703e-01 -7.53241463e-01 8.97277907e-01 -2.14527816 0.68309499 182.75 -5.74847347e-01 -7.02649016e-01 9.07835400e-01 -2.25648551 0.66539385 183.00 -6.28829400e-01 -7.60115390e-01 9.86509919e-01 -2.26195238 0.71249653 183.25 -6.67625706e-01 -6.94378110e-01 9.63267898e-01 -2.33655507 0.66080345 183.50 -7.15552763e-01 -5.80418430e-01 9.21358405e-01 -2.46009166 0.65832197 183.75 -6.92654477e-01 -4.78699798e-01 8.41976081e-01 -2.53685871 0.62110365 184.00 -6.15092533e-01 -4.21043985e-01 7.45397117e-01 -2.54133074 0.59514651 184.25 -5.96672201e-01 -4.00180917e-01 7.18444488e-01 -2.55081118 0.55029913 184.50 -7.07674689e-01 -3.19586803e-01 7.76491591e-01 -2.71740789 0.58455508 184.75 -6.39081859e-01 -3.00221207e-01 7.06086677e-01 -2.70242053 0.49146379 185.00 -5.27542262e-01 -3.02370800e-01 6.08053401e-01 -2.62113561 0.48581983 185.25 -4.79433915e-01 -3.03116622e-01 5.67218270e-01 -2.57780499 0.41271862 185.50 -5.85365151e-01 -3.99253484e-01 7.08558893e-01 -2.54300948 0.54771459 185.75 -5.99193246e-01 -3.60775654e-01 6.99422346e-01 -2.59962875 0.49771521 186.00 -4.78569963e-01 -2.75645319e-01 5.52276698e-01 -2.61902440 0.46204804 186.25 -4.79115699e-01 -2.74804588e-01 5.52330892e-01 -2.62083655 0.39398714 186.50 -4.72165632e-01 -4.08633871e-01 6.24437366e-01 -2.42819944 0.46505516 186.75 -5.17891404e-01 -3.96362692e-01 6.52161705e-01 -2.48834640 0.45389708 187.00 -5.82890444e-01 -3.42978137e-01 6.76310041e-01 -2.60973935 0.64299443 187.25 -4.53446056e-01 -3.36123943e-01 5.64440103e-01 -2.50370506 0.52319455 187.50 -4.58754158e-01 -3.26519388e-01 5.63089947e-01 -2.52302262 0.64992604 187.75 -4.00856975e-01 -3.22731091e-01 5.14627702e-01 -2.46374796 0.52390875 188.00 -3.15968904e-01 -3.16772839e-01 4.47416338e-01 -2.35492393 0.54369079 188.25 -2.64475339e-01 -2.87264821e-01 3.90471871e-01 -2.31491322 0.45861881 188.50 -1.89737198e-01 -2.89242767e-01 3.45921353e-01 -2.15136328 0.45199957 188.75 -6.44081190e-02 -2.82030729e-01 2.89291787e-01 -1.79531862 0.21958206 189.00 1.45101917e-01 -2.78343439e-01 3.13894308e-01 -1.09025009 0.22885115 189.25 2.78209136e-01 -3.75236683e-01 4.67121923e-01 -0.93280709 0.30686230 189.50 2.95298792e-01 -4.27012647e-01 5.19173552e-01 -0.96576690 0.36267603 189.75 3.02462216e-01 -4.70978114e-01 5.59735452e-01 -0.99992386 0.33837428 190.00 3.06967908e-01 -5.32142416e-01 6.14332848e-01 -1.04757064 0.46071057 190.25 2.54230078e-01 -4.04890624e-01 4.78089270e-01 -1.01011566 0.31331342 190.50 2.29340807e-01 -3.80639128e-01 4.44390989e-01 -1.02852957 0.34242959 190.75 1.50142174e-01 -3.35712480e-01 3.67757449e-01 -1.15024464 0.28820781 191.00 9.39309409e-02 -2.68533204e-01 2.84487440e-01 -1.23430624 0.25161057 191.25 2.61721231e-02 -8.42028894e-02 8.81765650e-02 -1.26944076 0.02536724 191.50 -3.96234575e-02 5.73836836e-02 6.97345361e-02 2.17511824 0.01498490 191.75 -4.21097126e-02 4.68443499e-01 4.70332372e-01 1.66044819 0.31594905 192.00 2.26659067e-02 6.60656451e-01 6.61045149e-01 1.53650162 0.49453919 192.25 1.82642961e-01 7.64745230e-01 7.86252961e-01 1.33635933 0.52913653 192.50 2.28832207e-01 7.63840392e-01 7.97380915e-01 1.27972381 0.51587921 192.75 5.38947775e-01 8.91774332e-01 1.04198184e+00 1.02718118 0.55579053 193.00 6.08615986e-01 9.28967033e-01 1.11058236e+00 0.99080680 0.56021635 193.25 6.98653022e-01 1.03224380e+00 1.24645229e+00 0.97579090 0.70751096 193.50 6.69246202e-01 1.04050441e+00 1.23714992e+00 0.99922053 0.72385200 193.75 7.82026412e-01 1.01468312e+00 1.28107265e+00 0.91417204 0.77459645 194.00 8.39312872e-01 9.57680677e-01 1.27341995e+00 0.85117306 0.74662227 194.25 8.52800823e-01 9.26624478e-01 1.25932608e+00 0.82686174 0.81126947 194.50 9.30586466e-01 8.52151582e-01 1.26180565e+00 0.74142965 0.79206131 194.75 9.51680521e-01 7.07403688e-01 1.18579753e+00 0.63921254 0.74027953 195.00 8.88860450e-01 6.18562652e-01 1.08290935e+00 0.60797252 0.64546752 195.25 7.37273691e-01 4.52499723e-01 8.65059821e-01 0.55046652 0.63833182 195.50 7.23052537e-01 3.96881808e-01 8.24815217e-01 0.50199645 0.65498185 195.75 5.66528854e-01 3.38265669e-01 6.59832255e-01 0.53827309 0.65518303 196.00 5.73655333e-01 3.62246849e-01 6.78456498e-01 0.56323927 0.57149014 196.25 6.05293155e-01 2.84806933e-01 6.68950516e-01 0.43979266 0.56996385 196.50 4.45625925e-01 1.21354613e-01 4.61854313e-01 0.26587661 0.34134935 196.75 2.64432523e-01 -2.66285780e-02 2.65769902e-01 -0.10036251 0.16784311 197.00 3.52782713e-02 8.76719458e-02 9.45035794e-02 1.18823173 0.01942840 197.25 -2.01336399e-01 1.23604271e-01 2.36250633e-01 2.59100130 0.18092227 197.50 -2.67153120e-01 2.89037551e-01 3.93590517e-01 2.31686778 0.29450472 197.75 -3.35051175e-01 5.80456654e-01 6.70215799e-01 2.09429738 0.50160668 198.00 -1.66367634e-01 8.85210424e-01 9.00708435e-01 1.75657060 0.58740706 198.25 -3.09383133e-02 1.03429624e+00 1.03475886e+00 1.60069984 0.79580063 198.50 1.29068487e-01 9.53086550e-01 9.61786174e-01 1.43619359 0.71067173 198.75 2.59490359e-01 9.01239399e-01 9.37852707e-01 1.29045297 0.71124513 199.00 2.55696606e-01 7.95790037e-01 8.35860357e-01 1.25990403 0.57429967 199.25 2.44989950e-01 6.75688975e-01 7.18731986e-01 1.22296041 0.52846980 199.50 1.05308068e-01 6.22505238e-01 6.31349793e-01 1.40321475 0.39988829 199.75 -7.87606867e-02 5.45060272e-01 5.50721296e-01 1.71430207 0.40074857 200.00 -3.03823276e-01 4.05719979e-01 5.06870087e-01 2.21356082 0.33943402 200.25 -3.47457630e-01 4.50645559e-01 5.69041496e-01 2.22761631 0.37633550 200.50 -4.36433251e-01 8.00609498e-01 9.11838555e-01 2.06988999 0.45477529 200.75 -4.96036795e-01 1.02009106e+00 1.13430079e+00 2.02339744 0.54994018 201.00 -3.38173706e-01 1.01387396e+00 1.06878523e+00 1.89273836 0.41058106 201.25 -2.12547723e-01 1.06590841e+00 1.08689341e+00 1.76761994 0.44082749 201.50 1.99447820e-01 1.36741046e+00 1.38187945e+00 1.42595963 0.47576086 201.75 3.28371086e-01 1.35095982e+00 1.39029494e+00 1.33235527 0.53497760 202.00 3.14998375e-01 1.41026319e+00 1.44501427e+00 1.35104206 0.57371530 202.25 3.24805991e-01 1.43790218e+00 1.47413080e+00 1.34863608 0.60279858 202.50 2.30706897e-01 1.28933994e+00 1.30981799e+00 1.39373602 0.49514153 202.75 1.50454194e-01 1.18591939e+00 1.19542514e+00 1.44460335 0.49102413 203.00 3.03999634e-01 9.78708936e-01 1.02483509e+00 1.26963158 0.38922484 203.25 5.07082428e-01 1.14526094e+00 1.25249958e+00 1.15397459 0.42141573 203.50 5.60603354e-01 1.36523767e+00 1.47585569e+00 1.18116250 0.44065580 203.75 5.56935861e-01 1.37320475e+00 1.48184643e+00 1.18549421 0.40022490 204.00 3.61236529e-01 1.55836119e+00 1.59968167e+00 1.34301393 0.36846752 204.25 6.53215313e-01 1.74880374e+00 1.86681675e+00 1.21332275 0.41455021 204.50 1.17904337e+00 2.04736896e+00 2.36259665e+00 1.04829929 0.46982742 204.75 1.44006061e+00 2.01284276e+00 2.47493647e+00 0.94978543 0.45501015 205.00 1.47787421e+00 2.08090821e+00 2.55231094e+00 0.95325326 0.46156889 205.25 1.30277699e+00 1.62582344e+00 2.08339381e+00 0.89526146 0.31291271 205.50 8.46386607e-01 7.59487390e-01 1.13718573e+00 0.73133754 0.07943946 205.75 8.60502143e-01 6.23496561e-01 1.06264383e+00 0.62702821 0.07024042 206.00 8.92730441e-01 9.10914141e-01 1.27543413e+00 0.79547946 0.08558725 206.25 4.17431137e-01 7.26253641e-01 8.37671239e-01 1.04913250 0.04870110 206.50 -5.09026097e-02 9.81961446e-01 9.83279897e-01 1.62258766 0.05716176 206.75 2.25752939e-02 1.28962281e+00 1.28982039e+00 1.55329277 0.09645294 207.00 -9.86431099e-01 1.55147377e+00 1.83850950e+00 2.13712614 0.13429951 207.25 -6.68183362e-01 1.65700349e+00 1.78665317e+00 1.95409957 0.17254713 207.50 4.64035477e-02 1.75168444e+00 1.75229897e+00 1.54431171 0.20108772 207.75 3.58093861e-01 1.97841594e+00 2.01056232e+00 1.39173466 0.29000212 208.00 1.15296966e-01 2.50158837e+00 2.50424395e+00 1.52473942 0.44486480 208.25 3.77648114e-01 2.54329206e+00 2.57117727e+00 1.42338553 0.42488916 208.50 6.69431158e-01 2.56626654e+00 2.65214291e+00 1.31562476 0.43469469 208.75 5.55742168e-01 2.10737577e+00 2.17942240e+00 1.31295363 0.27676818 209.00 4.28270702e-01 1.60585877e+00 1.66198621e+00 1.31016969 0.13514815 209.25 7.85008003e-01 1.73991348e+00 1.90880498e+00 1.14696449 0.20504085 209.50 8.23502725e-01 1.89501415e+00 2.06621281e+00 1.16085383 0.21166828 209.75 3.41518087e-01 1.20404290e+00 1.25154061e+00 1.29441287 0.07558399 210.00 5.48517881e-03 1.48764416e+00 1.48765427e+00 1.56710919 0.10345961 210.25 3.05822252e-01 1.69864205e+00 1.72595251e+00 1.39266536 0.18601729 210.50 6.90420335e-01 2.14580708e+00 2.25414469e+00 1.25950383 0.29872149 210.75 -9.33297151e-02 1.77779677e+00 1.78024487e+00 1.62324558 0.22630033 211.00 1.64424541e-01 1.90715496e+00 1.91422974e+00 1.48479442 0.20037163 211.25 3.06295392e-01 1.66544332e+00 1.69337484e+00 1.38891654 0.25469920 211.50 7.73435580e-01 1.31993547e+00 1.52984713e+00 1.04076084 0.21070118 211.75 4.96736665e-01 1.36870342e+00 1.45605507e+00 1.22265377 0.15145450 212.00 4.83414303e-01 1.36832775e+00 1.45120992e+00 1.23119500 0.16726588 212.25 6.04167146e-01 1.09647619e+00 1.25190973e+00 1.06717956 0.14768551 212.50 6.60128170e-01 1.13719544e+00 1.31490786e+00 1.04484754 0.15077997 212.75 7.66778121e-01 1.10529975e+00 1.34522720e+00 0.96429172 0.18526706 213.00 8.88231633e-01 1.19788244e+00 1.49126717e+00 0.93275648 0.21370597 213.25 8.96825425e-01 9.46480816e-01 1.30388718e+00 0.81232987 0.16640648 213.50 8.27876427e-01 1.22751826e+00 1.48060139e+00 0.97743763 0.22098402 213.75 9.26101620e-01 4.33089072e-01 1.02236508e+00 0.43743225 0.11095114 214.00 1.24306761e+00 2.17688107e-01 1.26198463e+00 0.17336374 0.19445433 214.25 1.55061184e+00 5.29039789e-01 1.63837730e+00 0.32879703 0.32315759 214.50 1.47772126e+00 5.53600497e-01 1.57801573e+00 0.35844730 0.32004947 214.75 1.47642526e+00 5.28260120e-01 1.56808492e+00 0.34360372 0.30991768 215.00 1.13170287e+00 5.47603358e-01 1.25722743e+00 0.45066505 0.22153911 215.25 9.86253421e-01 8.30483044e-01 1.28934010e+00 0.69986549 0.25695891 215.50 1.08703737e+00 8.90677925e-01 1.40533178e+00 0.68643649 0.28081185 215.75 7.55582002e-01 1.10727548e+00 1.34050854e+00 0.97199440 0.25038760 216.00 8.68209742e-01 1.31982838e+00 1.57978958e+00 0.98894325 0.29271243 216.25 7.19747932e-01 1.33563631e+00 1.51722162e+00 1.07653047 0.28938117 216.50 8.40752383e-01 6.53972536e-01 1.06515006e+00 0.66108320 0.12278984 216.75 7.78624758e-01 -2.89233805e-01 8.30609841e-01 -0.35567011 0.06276232 217.00 7.68029211e-01 1.99150335e-03 7.68031793e-01 0.00259300 0.06988084 217.25 1.40725905e+00 -1.18340004e-01 1.41222604e+00 -0.08389517 0.19959634 217.50 1.24974517e+00 1.21702897e-01 1.25565703e+00 0.09707608 0.21048476 217.75 1.56140174e+00 -3.94217291e-01 1.61039829e+00 -0.24730815 0.36854714 218.00 1.30994454e+00 -3.80014467e-01 1.36395224e+00 -0.28234935 0.26779951 218.25 1.15204442e+00 -7.24272623e-01 1.36080020e+00 -0.56124455 0.36994430 218.50 1.35845435e+00 -6.95464552e-01 1.52612882e+00 -0.47316409 0.44000966 218.75 1.53450925e+00 -8.71581498e-01 1.76475861e+00 -0.51654795 0.59917065 219.00 1.59288128e+00 -7.27086980e-01 1.75097866e+00 -0.42821326 0.59428302 219.25 1.76172915e+00 -7.38008172e-01 1.91006431e+00 -0.39670215 0.67891221 219.50 1.50739943e+00 -5.62774235e-01 1.60902700e+00 -0.35731554 0.69227550 219.75 1.54521290e+00 -5.74273681e-01 1.64847601e+00 -0.35582779 0.80151073 220.00 1.65013275e+00 -5.54676496e-01 1.74086303e+00 -0.32427490 0.80443944 220.25 1.70566892e+00 -6.25557982e-01 1.81676340e+00 -0.35152027 0.86251207 220.50 1.50317471e+00 -5.34230547e-01 1.59528571e+00 -0.34147872 0.79507681 220.75 1.42932226e+00 -4.61516090e-01 1.50198509e+00 -0.31232370 0.80215062 221.00 1.45458587e+00 -4.59649404e-01 1.52548275e+00 -0.30607046 0.81037256 221.25 1.47641760e+00 -5.37043604e-01 1.57105849e+00 -0.34886939 0.80229249 221.50 1.36926081e+00 -3.19851613e-01 1.40612240e+00 -0.22947948 0.68378724 221.75 1.47240997e+00 -2.18346631e-01 1.48851146e+00 -0.14721912 0.75733537 222.00 1.71566405e+00 -1.22194822e-01 1.72001009e+00 -0.07110298 0.81990641 222.25 1.84875833e+00 -1.20629726e-01 1.85268964e+00 -0.06515669 0.86535340 222.50 2.02525715e+00 -1.67668076e-01 2.03218580e+00 -0.08260017 0.83054391 222.75 2.02752288e+00 -2.79531847e-01 2.04670151e+00 -0.13700496 0.86009883 223.00 2.00103758e+00 -4.24677697e-01 2.04560567e+00 -0.20912584 0.87962127 223.25 1.94093007e+00 -5.45248637e-01 2.01606190e+00 -0.27386284 0.90353118 223.50 1.98325556e+00 -6.06798579e-01 2.07400750e+00 -0.29691646 0.92848734 223.75 1.85974519e+00 -6.32255813e-01 1.96428093e+00 -0.32771077 0.93674137 224.00 1.78663023e+00 -5.99922908e-01 1.88466312e+00 -0.32395506 0.91596282 224.25 1.74272076e+00 -4.84015829e-01 1.80868654e+00 -0.27090782 0.88804924 224.50 1.82069484e+00 -3.19916536e-01 1.84858765e+00 -0.17393568 0.87593472 224.75 1.82056188e+00 -4.23491947e-01 1.86916852e+00 -0.22855160 0.86182855 225.00 1.67350681e+00 -5.05054706e-01 1.74805758e+00 -0.29310207 0.87348941 225.25 1.59386592e+00 -4.09203899e-01 1.64555656e+00 -0.25130898 0.85720621 225.50 1.48118113e+00 -3.64218199e-01 1.52530405e+00 -0.24111343 0.87473494 225.75 1.47490015e+00 -3.11980626e-01 1.50753519e+00 -0.20845387 0.84996651 226.00 1.49337436e+00 -4.38275466e-02 1.49401735e+00 -0.02933958 0.76040352 226.25 1.46053338e+00 1.14305087e-01 1.46499946e+00 0.07810336 0.73111869 226.50 1.79356907e+00 1.26602702e-01 1.79803178e+00 0.07047014 0.72453818 226.75 1.73201633e+00 -1.75697795e-01 1.74090502e+00 -0.10109537 0.63290955 227.00 1.59870309e+00 -3.28319689e-01 1.63206783e+00 -0.20255007 0.74049191 227.25 1.62974594e+00 -1.12548968e-01 1.63362759e+00 -0.06894974 0.69472264 227.50 1.84214232e+00 1.34898849e-01 1.84707499e+00 0.07309885 0.77834078 227.75 1.98780103e+00 -1.39848977e-03 1.98780152e+00 -0.00070354 0.73364980 228.00 2.01439872e+00 -4.73939116e-02 2.01495618e+00 -0.02352323 0.78936618 228.25 1.96350900e+00 -7.62573575e-02 1.96498926e+00 -0.03881778 0.70344981 228.50 1.76821955e+00 -8.68654872e-02 1.77035194e+00 -0.04908650 0.64941795 228.75 1.78305273e+00 2.67934743e-02 1.78325403e+00 0.01502561 0.61698045 229.00 2.12796423e+00 1.40998317e-01 2.13263037e+00 0.06616301 0.65553378 229.25 2.25495597e+00 -2.30539413e-01 2.26671014e+00 -0.10188278 0.53396551 229.50 2.13370094e+00 -8.90403969e-01 2.31203350e+00 -0.39533486 0.55228742 229.75 1.71861272e+00 -4.65408093e-01 1.78051520e+00 -0.26446154 0.50812778 230.00 1.64585566e+00 -3.17487129e-01 1.67619776e+00 -0.19056033 0.62192659 230.25 1.80280008e+00 -2.88613305e-01 1.82575622e+00 -0.15874466 0.52125744 230.50 1.96374550e+00 -5.50178359e-01 2.03936084e+00 -0.27316435 0.49864665 230.75 1.81808162e+00 -2.68600583e-01 1.83781583e+00 -0.14667744 0.50459151 231.00 2.08677586e+00 -2.71858120e-01 2.10440973e+00 -0.12954702 0.55205438 231.25 1.91037517e+00 -4.36105796e-01 1.95952075e+00 -0.22443685 0.44655012 231.50 1.94316784e+00 -5.57324989e-01 2.02151240e+00 -0.27931477 0.57679910 231.75 1.73316132e+00 -4.39060939e-01 1.78791014e+00 -0.24810987 0.42490770 232.00 1.68957865e+00 -5.95884256e-01 1.79157865e+00 -0.33906227 0.43772373 232.25 1.76554315e+00 -5.12802714e-01 1.83850734e+00 -0.28267283 0.37012368 232.50 1.96197541e+00 -9.48603173e-01 2.17926489e+00 -0.45035576 0.47556983 232.75 2.22707253e+00 -1.41604247e+00 2.63913401e+00 -0.56635024 0.60189826 233.00 2.23278646e+00 -1.68001023e+00 2.79423867e+00 -0.64505298 0.67654366 233.25 2.14138110e+00 -1.06329447e+00 2.39083838e+00 -0.46088069 0.53232129 233.50 2.09429803e+00 -1.03028834e+00 2.33400478e+00 -0.45718629 0.50875607 233.75 1.76643041e+00 -1.23071519e+00 2.15289021e+00 -0.60852420 0.44695710 234.00 1.68172936e+00 -1.54731349e+00 2.28525550e+00 -0.74379503 0.47320694 234.25 1.81396051e+00 -1.38161267e+00 2.28019874e+00 -0.65091888 0.51997746 234.50 1.72592611e+00 -1.63604177e+00 2.37811977e+00 -0.75866890 0.62370124 234.75 1.64792318e+00 -1.49980442e+00 2.22824239e+00 -0.73837707 0.60677524 235.00 1.66287731e+00 -1.52296187e+00 2.25489996e+00 -0.74150845 0.59262576 235.25 1.59291215e+00 -1.58443667e+00 2.24673290e+00 -0.78273070 0.58302284 235.50 1.18811724e+00 -1.64829708e+00 2.03187249e+00 -0.94623674 0.50462885 235.75 6.98969289e-01 -1.66707458e+00 1.80767688e+00 -1.17378142 0.51648608 236.00 6.63055991e-01 -1.52402939e+00 1.66201950e+00 -1.16042923 0.54078101 236.25 9.59979544e-01 -1.16746234e+00 1.51146586e+00 -0.88261760 0.66278065 236.50 1.06444793e+00 -9.83050920e-01 1.44894393e+00 -0.74566472 0.66594804 236.75 1.39669288e+00 -8.52557658e-01 1.63633907e+00 -0.54804000 0.74935727 237.00 1.54759813e+00 -7.22707753e-01 1.70803000e+00 -0.43688993 0.71982365 237.25 1.81554589e+00 -5.80881256e-01 1.90620825e+00 -0.30965626 0.74506047 237.50 1.78653295e+00 -2.57840476e-01 1.80504340e+00 -0.14333477 0.68128649 237.75 1.81150036e+00 4.25639638e-02 1.81200035e+00 0.02349220 0.80281893 238.00 1.72041911e+00 4.52367049e-01 1.77889794e+00 0.25711995 0.71961782 238.25 1.25876667e+00 1.09512074e+00 1.66846725e+00 0.71598829 0.66676520 238.50 9.00651483e-01 1.40154960e+00 1.66598751e+00 0.99963288 0.62466801 238.75 4.73885112e-01 1.52686336e+00 1.59871162e+00 1.26985759 0.62287178 239.00 -2.28009074e-01 1.16633206e+00 1.18841012e+00 1.76385394 0.42281659 239.25 -7.80133211e-01 9.08109755e-01 1.19719303e+00 2.28053461 0.56550683 239.50 -9.36045478e-01 6.90500460e-01 1.16317326e+00 2.50602417 0.55981382 239.75 -1.07371588e+00 5.16518128e-01 1.19149350e+00 2.69321427 0.62629484 240.00 -8.67365322e-01 3.30029296e-01 9.28031216e-01 2.77801204 0.44444587 240.25 -8.35852590e-01 1.69937632e-01 8.52952725e-01 2.94101593 0.47346479 240.50 -6.78202250e-01 2.80978083e-01 7.34102837e-01 2.74882119 0.42833535 240.75 -4.98224179e-01 2.54502548e-01 5.59463028e-01 2.66932708 0.26238933 241.00 -9.38356133e-02 -4.28410390e-02 1.03152688e-01 -2.71330168 0.01145175 241.25 1.62289171e-01 -2.58813129e-01 3.05486515e-01 -1.01072311 0.12106938 241.50 3.39725762e-01 -6.35086223e-01 7.20241699e-01 -1.07959786 0.43635455 241.75 3.80399560e-01 -7.76045717e-01 8.64263143e-01 -1.11503816 0.63590684 242.00 3.79920994e-01 -9.00028624e-01 9.76929622e-01 -1.17136673 0.69219867 242.25 3.62381170e-01 -1.05635283e+00 1.11678173e+00 -1.24032698 0.74009899 242.50 3.28067641e-01 -1.23407449e+00 1.27693705e+00 -1.31096491 0.67401249 242.75 3.31101244e-01 -1.25675223e+00 1.29963618e+00 -1.31319210 0.68374842 243.00 1.72257736e-01 -1.46267420e+00 1.47278258e+00 -1.45356727 0.68010103 243.25 1.55595964e-02 -1.58499056e+00 1.58506693e+00 -1.56097980 0.73637233 243.50 -3.62666906e-01 -1.35226158e+00 1.40004952e+00 -1.83282305 0.59812139 243.75 -4.01998553e-01 -1.10916920e+00 1.17977080e+00 -1.91850332 0.51359634 244.00 -3.63082184e-01 -8.19400557e-01 8.96239893e-01 -1.98790333 0.27931371 244.25 -4.44849028e-01 -7.59301628e-01 8.80016829e-01 -2.10075837 0.29404012 244.50 -4.46610537e-01 -5.78358155e-01 7.30725070e-01 -2.22835727 0.20817984 244.75 -2.24070239e-01 -2.84581915e-01 3.62207590e-01 -2.23778624 0.09184869 245.00 2.62811563e-01 -1.16427222e-01 2.87446022e-01 -0.41702290 0.05233306 245.25 6.63793001e-01 -2.54397577e-01 7.10872193e-01 -0.36598242 0.24674833 245.50 7.35187192e-01 -8.46930879e-01 1.12151332e+00 -0.85591024 0.55089911 245.75 8.19965331e-01 -7.93244650e-01 1.14086819e+00 -0.76883601 0.53650944 246.00 4.29002024e-01 -8.74017844e-01 9.73627202e-01 -1.11450436 0.31257433 246.25 4.97643535e-01 -1.15006450e+00 1.25311509e+00 -1.16241405 0.39533788 246.50 5.51703280e-01 -1.15495909e+00 1.27996368e+00 -1.12516192 0.42999306 246.75 2.58594375e-01 -8.98662741e-01 9.35128746e-01 -1.29061132 0.26090723 247.00 1.89066255e-01 -7.87552371e-01 8.09928877e-01 -1.33518689 0.22458419 247.25 2.32064278e-01 -7.01848769e-01 7.39219536e-01 -1.25146530 0.16922883 247.50 4.19671635e-01 -9.95123299e-01 1.07999753e+00 -1.17170012 0.26249801 247.75 4.09224515e-01 -9.76620359e-01 1.05889189e+00 -1.17400076 0.24454633 248.00 6.00410969e-01 -9.79685883e-01 1.14903340e+00 -1.02097406 0.33417582 248.25 5.35772436e-01 -8.30129885e-01 9.88012009e-01 -0.99765603 0.21197498 248.50 3.23172708e-01 -8.95822761e-01 9.52333460e-01 -1.22457236 0.14551253 248.75 1.40971239e-01 -7.41881107e-01 7.55155923e-01 -1.38301639 0.07915975 249.00 -9.69817794e-02 -1.19438010e+00 1.19831102e+00 -1.65181700 0.19124929 249.25 1.29850882e-01 -6.63411896e-01 6.76000440e-01 -1.37750804 0.07359716 249.50 1.04842513e-01 -5.24413954e-01 5.34791500e-01 -1.37347462 0.06332582 249.75 3.55441081e-01 -5.45156637e-01 6.50794992e-01 -0.99301776 0.03319736 250.00 6.78662382e-01 3.62237615e-01 7.69284549e-01 0.49028346 0.02053483 250.25 2.05782261e-01 -3.72874542e-01 4.25889379e-01 -1.06651035 0.01538493 250.50 -8.05268461e-02 -7.57948415e-01 7.62214125e-01 -1.67664244 0.07788255 250.75 -3.02620554e-01 -7.07150692e-01 7.69182228e-01 -1.97515752 0.07732970 251.00 -2.41321320e-01 -6.64348719e-01 7.06820487e-01 -1.91922159 0.08780328 251.25 -2.19230041e-01 -5.48462954e-01 5.90655080e-01 -1.95105883 0.06917018 251.50 -1.38285669e-02 -7.06703269e-01 7.06838553e-01 -1.59036154 0.12603090 251.75 2.08272762e-01 -4.80126279e-01 5.23353405e-01 -1.16150622 0.06037485 252.00 5.90508485e-01 -3.55059712e-01 6.89033867e-01 -0.54135862 0.10293481 252.25 7.03754680e-01 -6.51062225e-01 9.58724502e-01 -0.74652508 0.19390328 252.50 7.06855539e-01 -1.34645819e+00 1.52072167e+00 -1.08736971 0.40035246 252.75 4.05751289e-01 -1.72575331e+00 1.77281093e+00 -1.33987495 0.46391007 253.00 2.52619374e-01 -1.77733847e+00 1.79520155e+00 -1.42960849 0.52252603 253.25 -2.33665831e-03 -1.94489302e+00 1.94489443e+00 -1.57199776 0.56119257 253.50 1.61232725e-01 -2.11923879e+00 2.12536327e+00 -1.49486212 0.63757742 253.75 3.91058044e-01 -1.90427549e+00 1.94401428e+00 -1.36825427 0.49832824 254.00 3.38875859e-01 -1.95269930e+00 1.98188582e+00 -1.39896543 0.52270873 254.25 1.29833430e-01 -1.98565092e+00 1.98989103e+00 -1.50550344 0.55066677 254.50 1.62484073e-01 -1.99148085e+00 1.99809835e+00 -1.48938708 0.59121631 254.75 2.17686277e-01 -2.55737886e+00 2.56662696e+00 -1.48588016 0.68591678 255.00 1.10259713e-01 -2.57620572e+00 2.57856416e+00 -1.52802317 0.73078864 255.25 -5.94837186e-02 -2.75750863e+00 2.75815013e+00 -1.59236453 0.68285299 255.50 -4.20743972e-01 -2.96375828e+00 2.99347434e+00 -1.71181700 0.70125871 255.75 -8.10202999e-01 -3.26977236e+00 3.36865555e+00 -1.81368991 0.75794239 256.00 -1.02926719e+00 -3.32065963e+00 3.47651712e+00 -1.87136428 0.71107913 256.25 -2.01474488e+00 -3.44226671e+00 3.98853320e+00 -2.10033389 0.71638844 256.50 -2.70505182e+00 -3.12047268e+00 4.12972821e+00 -2.28500453 0.71235853 256.75 -3.43726378e+00 -2.27293558e+00 4.12080313e+00 -2.55734034 0.65596347 257.00 -3.12402039e+00 -1.42867746e+00 3.43520344e+00 -2.71266799 0.56111657 257.25 -2.23390625e+00 -1.50860902e-01 2.23899445e+00 -3.07416270 0.50676720 257.50 -2.00491965e+00 -1.52090683e-01 2.01068008e+00 -3.06587892 0.60461848 257.75 -1.69002737e+00 -4.68821472e-01 1.75384893e+00 -2.87099222 0.71811513 258.00 -1.63046361e+00 -3.47791825e-01 1.66714449e+00 -2.93143377 0.68130719 258.25 -1.44440941e+00 -3.43351229e-01 1.48465774e+00 -2.90821364 0.71531388 258.50 -1.20117738e+00 -3.46407675e-01 1.25013015e+00 -2.86082087 0.61589855 258.75 -9.48502540e-01 -3.46314355e-01 1.00974784e+00 -2.79151460 0.59917655 259.00 -8.43429310e-01 -4.67738718e-01 9.64444145e-01 -2.63524928 0.57992875 259.25 -8.97395287e-01 -6.10958446e-01 1.08562817e+00 -2.54386022 0.69614531 259.50 -8.53877657e-01 -6.74387251e-01 1.08807409e+00 -2.47310608 0.62892287 259.75 -6.86649477e-01 -8.29169879e-01 1.07657336e+00 -2.26244806 0.66883092 260.00 -7.05674845e-01 -9.02798281e-01 1.14587160e+00 -2.23424943 0.64638457 260.25 -8.37822636e-01 -1.00807443e+00 1.31078634e+00 -2.26422215 0.68210651 260.50 -8.66010092e-01 -9.20387080e-01 1.26375862e+00 -2.32576441 0.50350978 260.75 -9.29736903e-01 -1.35347888e+00 1.64204622e+00 -2.17269232 0.58628226 261.00 -1.22942746e+00 -1.13659440e+00 1.67431739e+00 -2.39541030 0.54261732 261.25 -1.67323567e+00 -1.08045926e+00 1.99176049e+00 -2.56822472 0.60544262 261.50 -1.72578645e+00 -2.93536413e-01 1.75057205e+00 -2.97311649 0.36058680 261.75 -1.50821603e+00 7.58079273e-01 1.68801652e+00 2.67584080 0.34711990 262.00 -6.76267868e-01 7.01941408e-01 9.74710198e-01 2.33756846 0.23437725 262.25 -2.57001235e-01 5.41585230e-01 5.99469929e-01 2.01386533 0.16913598 262.50 -2.03566240e-01 1.84575723e-01 2.74786119e-01 2.40508224 0.06636385 262.75 -2.27798585e-01 1.52286220e-01 2.74013299e-01 2.55231320 0.11100550 263.00 -1.56254087e-01 -1.01910854e-01 1.86550695e-01 -2.56366371 0.04769511 263.25 -1.82321123e-01 -2.55730656e-01 3.14068719e-01 -2.19015548 0.16158129 263.50 -1.67563983e-01 -2.19675666e-01 2.76288050e-01 -2.22242595 0.11144858 263.75 -1.96675149e-01 -2.98460459e-01 3.57434973e-01 -2.15344839 0.19669201 264.00 -1.60782076e-01 -5.16884392e-01 5.41313541e-01 -1.87236880 0.28419309 264.25 -1.52726194e-01 -5.75968194e-01 5.95873016e-01 -1.82999556 0.38715900 264.50 -1.58049424e-01 -7.27601760e-01 7.44569636e-01 -1.78469313 0.48441615 264.75 -1.59956335e-01 -7.49513781e-01 7.66392157e-01 -1.78105556 0.47986583 265.00 -4.11573987e-01 -7.44600484e-01 8.50777896e-01 -2.07574437 0.50681017 265.25 -4.58525227e-01 -9.11656590e-01 1.02047201e+00 -2.03680776 0.57660026 265.50 -4.07590883e-01 -7.63125557e-01 8.65153711e-01 -2.06135598 0.63465517 265.75 -3.73152214e-01 -7.58798603e-01 8.45587308e-01 -2.02783598 0.62391887 266.00 -4.06971635e-01 -7.94338168e-01 8.92523970e-01 -2.04426755 0.60703766 266.25 -3.57933862e-01 -8.20864180e-01 8.95508041e-01 -1.98198501 0.59004857 266.50 -3.23732519e-01 -7.89936758e-01 8.53699494e-01 -1.95974014 0.61565524 266.75 -3.30244298e-01 -7.54393473e-01 8.23511268e-01 -1.98342610 0.55110876 267.00 -3.12501142e-01 -8.84639602e-01 9.38213296e-01 -1.91036574 0.56936120 267.25 -2.73524514e-01 -8.56954827e-01 8.99548351e-01 -1.87975703 0.55626094 267.50 -5.62192498e-02 -7.93983875e-01 7.95971732e-01 -1.64148489 0.50336693 267.75 -7.78495131e-03 -8.14186134e-01 8.14223352e-01 -1.58035767 0.44704491 268.00 4.09875899e-02 -9.51334073e-01 9.52216625e-01 -1.52773863 0.62499378 268.25 3.21467232e-02 -1.11399061e+00 1.11445435e+00 -1.54194707 0.64118156 268.50 -2.06576980e-01 -1.62510678e+00 1.63818378e+00 -1.69723417 0.83027216 268.75 -2.77675843e-01 -1.57391075e+00 1.59821742e+00 -1.74542348 0.80766678 269.00 -5.84822796e-01 -1.51188557e+00 1.62105388e+00 -1.93988651 0.86613544 269.25 -5.71924291e-01 -1.52584059e+00 1.62950511e+00 -1.92941419 0.82010459 269.50 -5.58995716e-01 -1.53839120e+00 1.63680289e+00 -1.91932660 0.78350620 269.75 -4.34952698e-01 -1.44990119e+00 1.51373621e+00 -1.86224195 0.70415662 270.00 -4.10915397e-01 -1.67436029e+00 1.72404578e+00 -1.81145634 0.70889686 270.25 -5.88067264e-01 -2.22966537e+00 2.30591213e+00 -1.82867079 0.59663558 270.50 -5.97864016e-01 -2.30917697e+00 2.38531751e+00 -1.82414111 0.49178905 270.75 -8.25339947e-01 -2.42822736e+00 2.56465868e+00 -1.89843983 0.57202044 271.00 -9.65459933e-01 -3.01113210e+00 3.16212419e+00 -1.88107084 0.72778891 271.25 -1.63207399e+00 -3.79800684e+00 4.13382649e+00 -1.97665683 0.78267227 271.50 -2.43713433e+00 -4.54029172e+00 5.15304498e+00 -2.06343261 0.81616650 271.75 -3.71908840e+00 -4.39165268e+00 5.75484421e+00 -2.27346111 0.73419621 272.00 -5.10540319e+00 -4.09252613e+00 6.54323405e+00 -2.46587270 0.73612102 272.25 -7.52282797e+00 -1.76211568e+00 7.72644759e+00 -2.91150501 0.69824973 272.50 -9.55622946e+00 -3.61346456e-01 9.56305875e+00 -3.10379800 0.82658277 272.75 -8.39177856e+00 2.71096850e+00 8.81880364e+00 2.82912499 0.81776976 273.00 -7.82316020e+00 4.94694981e+00 9.25603306e+00 2.57772773 0.86074904 273.25 -4.50580301e+00 7.22849177e+00 8.51782566e+00 2.12820054 0.77233595 273.50 -2.46439031e+00 7.59682312e+00 7.98654751e+00 1.88448317 0.85730711 273.75 -6.38373009e-01 6.43049932e+00 6.46210814e+00 1.66974483 0.82477382 274.00 4.58885601e-01 5.66322140e+00 5.68178252e+00 1.48994389 0.82314366 274.25 9.32273609e-01 3.83042754e+00 3.94224672e+00 1.33205194 0.71748880 274.50 9.76823408e-01 3.41168338e+00 3.54876985e+00 1.29193941 0.75768082 274.75 1.35429510e+00 2.80716696e+00 3.11677743e+00 1.12129356 0.80245312 275.00 1.55141963e+00 2.42295277e+00 2.87708237e+00 1.00126947 0.82637813 275.25 1.40447392e+00 2.20115262e+00 2.61105723e+00 1.00285853 0.81545629 275.50 1.32985623e+00 2.01573163e+00 2.41488956e+00 0.98760533 0.83929068 275.75 1.31941463e+00 1.61062982e+00 2.08206229e+00 0.88446217 0.77875986 276.00 1.28940905e+00 1.42424017e+00 1.92120685e+00 0.83504361 0.77486553 276.25 1.29614979e+00 1.27656654e+00 1.81923786e+00 0.77778642 0.66897979 276.50 1.24971721e+00 1.16770560e+00 1.71035946e+00 0.75148595 0.56957332 276.75 1.23805494e+00 1.37620010e+00 1.85113662e+00 0.83819209 0.58537746 277.00 1.33718350e+00 1.38392006e+00 1.92439457e+00 0.80257207 0.51726483 277.25 1.55739834e+00 1.46090368e+00 2.13535223e+00 0.75343920 0.47636443 277.50 1.67678975e+00 1.38625328e+00 2.17561992e+00 0.69082886 0.43581320 277.75 1.69864182e+00 1.14292178e+00 2.04735298e+00 0.59226737 0.26572759 278.00 1.51019386e+00 7.68878304e-01 1.69465612e+00 0.47092138 0.15876522 278.25 1.39726433e+00 -6.78418627e-01 1.55325447e+00 -0.45200757 0.11725382 278.50 3.66258250e-01 -2.08225326e+00 2.11421941e+00 -1.39668224 0.22929506 278.75 -1.53026704e+00 -3.06608980e+00 3.42675121e+00 -2.03371888 0.49556201 279.00 -1.80226869e+00 -2.23610210e+00 2.87198974e+00 -2.24917709 0.51025367 279.25 -1.55265127e+00 -1.24190779e+00 1.98823060e+00 -2.46693545 0.51587944 279.50 -1.40631535e+00 -6.36520302e-01 1.54365831e+00 -2.71656570 0.51033657 279.75 -1.34632999e+00 -4.72964052e-01 1.42698964e+00 -2.80376128 0.63447331 280.00 -1.19030745e+00 -3.82443516e-01 1.25023793e+00 -2.83071264 0.53241121 280.25 -7.87467639e-01 -5.80053540e-01 9.78042633e-01 -2.50671883 0.45891742 280.50 -8.62620409e-01 -6.29814361e-01 1.06807308e+00 -2.51093817 0.52247698 280.75 -7.63473187e-01 -6.84409863e-01 1.02533320e+00 -2.41074647 0.64366294 281.00 -7.03733185e-01 -6.00229542e-01 9.24941024e-01 -2.43540464 0.60001177 281.25 -7.71073847e-01 -5.79206401e-01 9.64383188e-01 -2.49734411 0.68701936 281.50 -6.79837470e-01 -4.41803923e-01 8.10783382e-01 -2.56531095 0.54774401 281.75 -5.98635013e-01 -4.00466147e-01 7.20233999e-01 -2.55200027 0.61235697 282.00 -4.80721720e-01 -3.95814955e-01 6.22706071e-01 -2.45275940 0.52466882 282.25 -4.53586093e-01 -3.54122759e-01 5.75450494e-01 -2.47872020 0.54817020 282.50 -4.54106746e-01 -3.50505670e-01 5.73643758e-01 -2.48424891 0.47853374 282.75 -4.18167258e-01 -3.92334672e-01 5.73402434e-01 -2.38805604 0.50442305 283.00 -4.73527140e-01 -4.14125701e-01 6.29069192e-01 -2.42301454 0.56580139 283.25 -5.19982218e-01 -3.95994395e-01 6.53600082e-01 -2.49073807 0.66493069 283.50 -4.86235466e-01 -4.52156630e-01 6.63980833e-01 -2.39249474 0.57268086 283.75 -5.01674850e-01 -5.97231395e-01 7.79976278e-01 -2.26945662 0.70187603 284.00 -6.35763445e-01 -6.50489040e-01 9.09577457e-01 -2.34474654 0.71498112 284.25 -7.28561024e-01 -6.14225419e-01 9.52929185e-01 -2.44113762 0.77790351 284.50 -7.83904803e-01 -5.01679642e-01 9.30692862e-01 -2.57229705 0.79133066 284.75 -8.70862565e-01 -4.54226214e-01 9.82203167e-01 -2.66082891 0.81983401 285.00 -8.21222371e-01 -2.77835044e-01 8.66947803e-01 -2.81536183 0.71402375 285.25 -7.77705989e-01 -2.02507726e-01 8.03639213e-01 -2.88685828 0.71014959 285.50 -8.13149957e-01 -9.17216056e-02 8.18306608e-01 -3.02926953 0.81275164 285.75 -8.26462847e-01 -4.18191838e-02 8.27520200e-01 -3.09103557 0.84644443 286.00 -6.92203351e-01 -5.26027687e-02 6.94199200e-01 -3.06574520 0.82005250 286.25 -6.90809615e-01 -5.98093617e-02 6.93393888e-01 -3.05522937 0.84917547 286.50 -5.96427018e-01 6.62876371e-02 6.00099357e-01 3.03090567 0.78611092 286.75 -5.59962043e-01 7.27854272e-02 5.64672656e-01 3.01233458 0.80987874 287.00 -4.11603742e-01 4.28304265e-02 4.13826154e-01 3.03790838 0.73885462 287.25 -4.00172829e-01 1.77170982e-02 4.00564837e-01 3.09734793 0.74992368 287.50 -4.16985497e-01 2.54081740e-02 4.17758878e-01 3.08073491 0.84122679 287.75 -4.09814670e-01 3.31118984e-02 4.11150169e-01 3.06097054 0.79389056 288.00 -3.98502746e-01 2.02268845e-02 3.99015746e-01 3.09087897 0.70164830 288.25 -3.59799295e-01 -1.29449177e-02 3.60032087e-01 -3.10563000 0.66103847 288.50 -3.38288649e-01 -4.32239536e-02 3.41038883e-01 -3.01450885 0.77264499 288.75 -3.31838076e-01 -4.00005942e-02 3.34240267e-01 -3.02162895 0.70987241 289.00 -2.52470481e-01 -1.07163283e-01 2.74272333e-01 -2.74018061 0.55790809 289.25 -2.71436585e-01 -1.13893479e-01 2.94362946e-01 -2.74430884 0.59127274 289.50 -3.01513225e-01 -1.17189486e-01 3.23486631e-01 -2.77089053 0.70566876 289.75 -2.89846806e-01 -1.19287781e-01 3.13433798e-01 -2.75116529 0.66293453 290.00 -2.69000350e-01 -1.11355357e-01 2.91137775e-01 -2.74911011 0.65211354 290.25 -2.65849515e-01 -1.18650598e-01 2.91125281e-01 -2.72181376 0.58723294 290.50 -2.73580377e-01 -1.57511400e-01 3.15683487e-01 -2.61920178 0.63518191 290.75 -2.57285664e-01 -1.82484736e-01 3.15430803e-01 -2.52467296 0.55172072 291.00 -2.57757636e-01 -2.03123222e-01 3.28173799e-01 -2.47418731 0.71739083 291.25 -2.69051552e-01 -2.26061936e-01 3.51415333e-01 -2.44280507 0.67106285 291.50 -3.15584178e-01 -2.56638625e-01 4.06763761e-01 -2.45884397 0.70592628 291.75 -3.23959805e-01 -2.88038629e-01 4.33493030e-01 -2.41482211 0.65639299 292.00 -3.59620990e-01 -2.74007954e-01 4.52114604e-01 -2.49049656 0.75136545 292.25 -3.84290958e-01 -2.41564612e-01 4.53908583e-01 -2.58041004 0.72641647 292.50 -3.94132195e-01 -1.93851052e-01 4.39224791e-01 -2.68449214 0.73745374 292.75 -3.76652543e-01 -1.69889287e-01 4.13194274e-01 -2.71786554 0.60173669 293.00 -3.72322533e-01 -1.65101423e-01 4.07286814e-01 -2.72421028 0.58688693 293.25 -3.93321115e-01 -2.23083706e-01 4.52181201e-01 -2.62565549 0.63145794 293.50 -4.63029994e-01 -2.37252987e-01 5.20274692e-01 -2.66808045 0.76404884 293.75 -4.93903317e-01 -1.82047030e-01 5.26385417e-01 -2.78845493 0.67456076 294.00 -5.29682744e-01 -1.43500814e-01 5.48777089e-01 -2.87702500 0.66300417 294.25 -4.99232428e-01 -1.19746120e-01 5.13392784e-01 -2.90617962 0.63308587 294.50 -4.71157130e-01 -1.03945378e-01 4.82486976e-01 -2.92445370 0.63309251 294.75 -4.58197786e-01 -5.38659432e-02 4.61353174e-01 -3.02456933 0.46982193 295.00 -4.65328561e-01 1.43204196e-02 4.65548863e-01 3.11082751 0.45274871 295.25 -4.50378814e-01 6.28955527e-02 4.54749301e-01 3.00283967 0.39412770 295.50 -4.03421016e-01 8.62157080e-02 4.12530804e-01 2.93104840 0.39852363 295.75 -3.10707943e-01 3.96656138e-02 3.13229607e-01 3.01461743 0.16238006 296.00 -3.05759135e-01 8.57822698e-02 3.17564554e-01 2.86806933 0.16487045 296.25 -3.88606664e-01 5.90431592e-02 3.93066449e-01 2.99081031 0.22792879 296.50 -2.57320129e-01 4.88225515e-02 2.61910845e-01 2.95408680 0.14331398 296.75 -1.96352362e-01 6.40116953e-02 2.06522994e-01 2.82645276 0.12013982 297.00 -2.03149346e-01 4.77505961e-02 2.08685831e-01 2.91073171 0.13592708 297.25 -1.31968847e-01 1.02817873e-01 1.67294027e-01 2.47972171 0.07180915 297.50 -1.38233209e-01 6.60272850e-02 1.53192762e-01 2.69598324 0.04837369 297.75 -1.56519908e-01 -1.42653173e-01 2.11774430e-01 -2.40251155 0.10180996 298.00 -2.10150821e-01 -1.41517995e-01 2.53358857e-01 -2.54893503 0.15388101 298.25 -1.95588750e-01 -1.16430573e-01 2.27620380e-01 -2.60464907 0.11079508 298.50 -2.29380072e-01 -1.35163932e-01 2.66241443e-01 -2.60910948 0.10348453 298.75 -3.37723646e-01 -1.58493617e-01 3.73064992e-01 -2.70280549 0.09566186 299.00 -3.55011601e-01 7.38647729e-03 3.55088436e-01 3.12078936 0.06429796 299.25 -4.02874935e-01 1.66066736e-01 4.35759537e-01 2.75060990 0.07046910 299.50 -1.98258271e-01 3.23008399e-02 2.00872313e-01 2.98008862 0.01517249 299.75 -2.14864267e-01 2.07152414e-01 2.98460677e-01 2.37446627 0.03653005 300.00 -1.17187486e-01 1.03014867e-01 1.56028746e-01 2.42046763 0.00956122 300.25 4.55042446e-02 5.45442795e-02 7.10331944e-02 0.87550997 0.00216551 300.50 2.13291414e-02 -4.96594859e-02 5.40462470e-02 -1.16511365 0.00174037 300.75 -7.64110393e-02 -3.14158188e-02 8.26171931e-02 -2.75151781 0.00698124 301.00 -1.27206258e-01 7.44895556e-02 1.47411418e-01 2.61184290 0.01583671 301.25 -4.12903881e-02 -2.03322579e-01 2.07472811e-01 -1.77114996 0.04274682 301.50 -1.07397254e-01 -1.40672706e-01 1.76982995e-01 -2.22285305 0.02273658 301.75 -7.00964444e-02 -5.39804917e-02 8.84726229e-02 -2.48535815 0.00548213 302.00 2.67213270e-01 -7.25151939e-02 2.76877925e-01 -0.26499364 0.04183869 302.25 3.04216502e-01 -7.27524212e-02 3.12794812e-01 -0.23473815 0.06234173 302.50 9.66393768e-02 -1.07112749e-02 9.72311707e-02 -0.11038702 0.00458490 302.75 1.41992470e-01 1.76884949e-01 2.26826248e-01 0.89438741 0.03535416 303.00 4.08150452e-01 1.37843057e-01 4.30798677e-01 0.32569881 0.12269617 303.25 6.00546058e-01 2.92327562e-01 6.67915392e-01 0.45300737 0.24147907 303.50 5.15484445e-01 -1.56807263e-02 5.15722889e-01 -0.03041002 0.14237235 303.75 5.27008506e-01 -2.49132795e-01 5.82928053e-01 -0.44159469 0.20160446 304.00 4.45657158e-01 2.50021176e-02 4.46357938e-01 0.05604294 0.10394518 304.25 3.33187368e-01 1.85137088e-01 3.81168681e-01 0.50717417 0.09732904 304.50 5.58260713e-01 -1.28580514e-01 5.72876926e-01 -0.22637553 0.17686445 304.75 5.87982200e-01 -2.30706525e-01 6.31623756e-01 -0.37391146 0.19770325 305.00 3.96401522e-01 -8.44984486e-02 4.05307481e-01 -0.21002041 0.06784589 305.25 3.29295549e-01 -1.87307827e-02 3.29827835e-01 -0.05682014 0.04584494 305.50 5.95697484e-01 -2.87678425e-01 6.61524276e-01 -0.44989619 0.12026579 305.75 7.00223147e-01 -6.63819490e-01 9.64867229e-01 -0.75871643 0.20892986 306.00 4.97094157e-01 -5.77718719e-01 7.62142716e-01 -0.86027059 0.14889232 306.25 4.87061139e-01 -8.08467132e-01 9.43847264e-01 -1.02857720 0.21390432 306.50 1.16195222e-01 -1.04873002e+00 1.05514737e+00 -1.46045026 0.24450337 306.75 -2.54424740e-02 -1.07106234e+00 1.07136449e+00 -1.59454629 0.28930316 307.00 -4.05898090e-01 -7.18874203e-01 8.25550349e-01 -2.08480251 0.23919570 307.25 -3.99654109e-01 -7.07839775e-01 8.12871794e-01 -2.08478793 0.26737090 307.50 -4.10223780e-01 -5.86681113e-01 7.15875882e-01 -2.18100389 0.29340791 307.75 -3.48053704e-01 -5.85540310e-01 6.81174600e-01 -2.10709879 0.28151799 308.00 -3.84263057e-01 -4.21626970e-01 5.70462443e-01 -2.30986413 0.20351364 308.25 -2.81054617e-01 -2.70223054e-01 3.89887415e-01 -2.37584007 0.10190779 308.50 -2.93133847e-01 -2.66398628e-01 3.96100595e-01 -2.40393953 0.13394523 308.75 -2.73882525e-01 -1.33768979e-01 3.04804490e-01 -2.68725402 0.07285180 309.00 -2.71486999e-01 -4.41415352e-02 2.75052115e-01 -2.98041140 0.09621392 309.25 -1.21230960e-01 4.26564786e-02 1.28516617e-01 2.80326066 0.02390375 309.50 4.02085071e-03 5.97080765e-02 5.98433091e-02 1.50355602 0.00505922 309.75 1.49665282e-01 5.16289927e-02 1.58320086e-01 0.33218053 0.02429837 310.00 3.06600042e-01 4.26438182e-02 3.09551419e-01 0.13819954 0.11562275 310.25 3.84815983e-01 4.99025266e-02 3.88038146e-01 0.12895926 0.13769518 310.50 4.68692619e-01 2.78339306e-01 5.45110576e-01 0.53589494 0.27848719 310.75 6.67249258e-01 3.27787859e-01 7.43415397e-01 0.45662514 0.39324646 311.00 9.84150235e-01 2.54542261e-01 1.01653502e+00 0.25309532 0.58505779 311.25 1.38319480e+00 1.96045640e-01 1.39701888e+00 0.14079614 0.63199087 311.50 1.84014844e+00 1.09060211e-01 1.84337745e+00 0.05919782 0.74878942 311.75 1.97347361e+00 -2.25533067e-01 1.98631903e+00 -0.11378862 0.66251091 312.00 2.33489616e+00 -6.52072751e-01 2.42423987e+00 -0.27233415 0.73803582 312.25 2.43110573e+00 -9.81026066e-01 2.62158105e+00 -0.38354647 0.70057216 312.50 2.30150579e+00 -1.68039856e+00 2.84967861e+00 -0.63066260 0.67413668 312.75 2.15885845e+00 -1.97176771e+00 2.92378824e+00 -0.74013554 0.51724335 313.00 2.06361627e+00 -2.31169858e+00 3.09878403e+00 -0.84203796 0.40881501 313.25 1.09196399e+00 -2.32773239e+00 2.57113271e+00 -1.13216415 0.22520477 313.50 1.18399819e+00 -3.16371394e+00 3.37800793e+00 -1.21268938 0.27691865 313.75 -2.14289660e-01 -1.00423975e+00 1.02684835e+00 -1.78102829 0.02578398 314.00 -2.61692564e+00 1.08370512e+00 2.83244004e+00 2.74897870 0.19120282 314.25 -2.61830335e+00 1.07260345e+00 2.82948592e+00 2.75279003 0.51791409 314.50 -2.50121738e+00 7.74680917e-01 2.61843826e+00 2.84124104 0.67944177 314.75 -2.21723393e+00 2.93508494e-01 2.23657630e+00 3.00998188 0.70241971 315.00 -2.07286475e+00 2.05757994e-01 2.08305176e+00 3.04265413 0.72929569 315.25 -1.98575398e+00 3.13603784e-01 2.01036470e+00 2.98495949 0.72111353 315.50 -2.06124451e+00 4.03398369e-01 2.10034739e+00 2.94832912 0.74481825 315.75 -1.65036247e+00 4.16014185e-01 1.70198828e+00 2.89466254 0.68280740 316.00 -1.57033922e+00 2.24409361e-01 1.58629280e+00 2.99964868 0.73373797 316.25 -1.43933870e+00 4.70904539e-03 1.43934640e+00 3.13832099 0.76231211 316.50 -1.44385902e+00 8.06462815e-03 1.44388154e+00 3.13600724 0.76693796 316.75 -1.36564928e+00 1.67043373e-01 1.37582755e+00 3.01987935 0.76216233 317.00 -1.33636088e+00 1.84333530e-01 1.34901417e+00 3.00452068 0.79559221 317.25 -1.36744696e+00 9.44206900e-02 1.37070291e+00 3.07265319 0.72346804 317.50 -1.24613044e+00 1.07104158e-01 1.25072474e+00 3.05585397 0.69476196 317.75 -1.34131305e+00 2.51594290e-01 1.36470524e+00 2.95617406 0.79165293 318.00 -1.34063071e+00 2.96939990e-01 1.37312201e+00 2.92361895 0.79577899 318.25 -1.31858299e+00 4.36775830e-01 1.38904076e+00 2.82172154 0.69692264 318.50 -1.28955705e+00 4.84580176e-01 1.37759767e+00 2.78214483 0.66728874 318.75 -1.06607325e+00 6.65775399e-01 1.25688865e+00 2.58334443 0.67915721 319.00 -1.03189236e+00 7.17394466e-01 1.25676436e+00 2.53408048 0.67174416 319.25 -8.48060661e-01 7.32031425e-01 1.12030214e+00 2.42949487 0.72346148 319.50 -7.92475658e-01 7.34554196e-01 1.08054964e+00 2.39410711 0.69221606 319.75 -4.61767588e-01 7.29152591e-01 8.63071728e-01 2.13533728 0.60237294 320.00 -4.39610847e-01 6.88665990e-01 8.17018080e-01 2.13893904 0.59804808 320.25 -3.88540719e-01 5.51589511e-01 6.74696138e-01 2.18447050 0.65126407 320.50 -4.48079416e-01 5.42194443e-01 7.03384658e-01 2.26143970 0.59703393 320.75 -4.43348303e-01 4.91364468e-01 6.61813235e-01 2.30486964 0.60914327 321.00 -3.60791002e-01 5.09378206e-01 6.24208542e-01 2.18706900 0.55120016 321.25 -3.34015890e-01 4.07813953e-01 5.27142140e-01 2.25703961 0.53929852 321.50 -2.60674340e-01 4.89690862e-01 5.54750621e-01 2.05996774 0.46887512 321.75 -9.95623091e-02 5.81143137e-01 5.89610039e-01 1.74047058 0.55509804 322.00 -4.69817814e-02 4.44767939e-01 4.47242448e-01 1.67603817 0.34419501 322.25 -7.37865333e-03 2.22571163e-01 2.22693438e-01 1.60393607 0.15272970 322.50 3.39427898e-02 1.96247365e-01 1.99161094e-01 1.39953149 0.11603924 322.75 7.65549451e-02 1.81173759e-01 1.96683986e-01 1.17100280 0.13688692 323.00 5.77619555e-02 1.39469070e-01 1.50957163e-01 1.17814636 0.06864311 323.25 4.67453591e-02 8.48951680e-02 9.69139729e-02 1.06747378 0.05130861 323.50 6.13264839e-02 3.19342967e-03 6.14095727e-02 0.05202561 0.01426001 323.75 6.01445329e-02 -1.05439256e-01 1.21386991e-01 -1.05241176 0.07412686 324.00 -5.87168150e-03 -1.68603327e-01 1.68705538e-01 -1.60560768 0.11072241 324.25 -3.00225921e-02 -2.04885863e-01 2.07073834e-01 -1.71629410 0.21139860 324.50 4.33873693e-03 -1.87814148e-01 1.87864257e-01 -1.54769921 0.10437573 324.75 -5.87101629e-03 -1.45376206e-01 1.45494708e-01 -1.61115938 0.08215159 325.00 2.46881647e-02 -2.68985120e-01 2.70115716e-01 -1.47927012 0.21811042 325.25 1.03438745e-03 -2.99378321e-01 2.99380108e-01 -1.56734122 0.33887649 325.50 -4.35540878e-02 -3.37562579e-01 3.40360769e-01 -1.69911264 0.30358669 325.75 -5.86846296e-02 -3.41874350e-01 3.46874555e-01 -1.74079509 0.29449775 326.00 -2.03257396e-01 -3.50958615e-01 4.05568143e-01 -2.09574324 0.30952245 326.25 -1.97394757e-01 -3.12282373e-01 3.69438724e-01 -2.13448742 0.31273405 326.50 -2.64823971e-01 -2.51105289e-01 3.64946026e-01 -2.38277847 0.29337117 326.75 -2.98796369e-01 -2.70385368e-01 4.02973346e-01 -2.40606861 0.36858889 327.00 -2.70780171e-01 -2.10731917e-01 3.43117825e-01 -2.48026165 0.32046857 327.25 -2.34115082e-01 -1.93013019e-01 3.03420331e-01 -2.45212799 0.28825500 327.50 -9.53222194e-02 -1.87654238e-01 2.10476694e-01 -2.04079745 0.12390987 327.75 -1.69785844e-03 -2.77077786e-01 2.77082988e-01 -1.57692398 0.18247829 328.00 -2.28450561e-02 -3.34192008e-01 3.34971931e-01 -1.63904922 0.20247297 328.25 -1.94421581e-02 -3.84483835e-01 3.84975086e-01 -1.62132020 0.24903303 328.50 -5.45439140e-02 -3.97878207e-01 4.01599435e-01 -1.70703409 0.26186136 328.75 -1.22517432e-01 -4.45341498e-01 4.61886968e-01 -1.83926383 0.31164646 329.00 -3.99729826e-01 -5.71329276e-01 6.97281203e-01 -2.18128653 0.58567292 329.25 -4.10225041e-01 -5.41126103e-01 6.79044950e-01 -2.21945819 0.56145096 329.50 -4.05080460e-01 -4.94891096e-01 6.39536844e-01 -2.25673104 0.46019316 329.75 -4.19051902e-01 -4.53410633e-01 6.17402380e-01 -2.31683350 0.38556481 330.00 -4.74097733e-01 -3.62319239e-01 5.96694136e-01 -2.48904700 0.39125169 330.25 -4.48684538e-01 -3.46517449e-01 5.66914594e-01 -2.48397389 0.34825216 330.50 -3.08151243e-01 -3.89109483e-01 4.96350057e-01 -2.24060308 0.36568285 330.75 -3.72577375e-01 -5.02639217e-01 6.25667710e-01 -2.20866881 0.46163370 331.00 -5.24849620e-01 -5.17504463e-01 7.37073939e-01 -2.36324107 0.58304917 331.25 -6.02700675e-01 -4.69864895e-01 7.64212748e-01 -2.47941567 0.53906293 331.50 -7.60874207e-01 -4.23372513e-01 8.70731787e-01 -2.63382691 0.65242319 331.75 -8.29241866e-01 -2.57768114e-01 8.68381525e-01 -2.84021358 0.67937529 332.00 -8.27365801e-01 -1.48280692e-01 8.40548233e-01 -2.96425511 0.77536820 332.25 -8.51244134e-01 -8.45403870e-02 8.55431851e-01 -3.04260334 0.68056131 332.50 -8.72077102e-01 -3.21549988e-02 8.72669706e-01 -3.10473761 0.69393808 332.75 -8.15695737e-01 1.27121134e-01 8.25541834e-01 2.98699244 0.61186602 333.00 -7.50059504e-01 3.49515094e-01 8.27496260e-01 2.70552692 0.66450782 333.25 -6.69146699e-01 2.20481059e-01 7.04534742e-01 2.82329980 0.49264481 333.50 -6.63936912e-01 2.05947840e-01 6.95145119e-01 2.84081193 0.48605292 333.75 -6.74565056e-01 1.70965207e-01 6.95893035e-01 2.89337418 0.28515964 334.00 -9.06826385e-01 3.62457433e-01 9.76580505e-01 2.76134594 0.39422847 334.25 -6.61461684e-01 1.01642554e+00 1.21270460e+00 2.14771434 0.42162209 334.50 -5.18218754e-01 1.33292460e+00 1.43011841e+00 1.94159585 0.64016811 334.75 -2.56575589e-01 1.13959230e+00 1.16811885e+00 1.79225051 0.46569779 335.00 -1.31296561e-01 8.86271184e-01 8.95943860e-01 1.71787151 0.38138357 335.25 -2.71565461e-01 6.92095009e-01 7.43467081e-01 1.94471806 0.20997646 335.50 -5.28432476e-01 5.77131733e-01 7.82510012e-01 2.31217371 0.16887303 335.75 -3.20306545e-01 7.46453568e-01 8.12274099e-01 1.97613833 0.08494816 336.00 -1.66288826e-01 8.29521388e-01 8.46024649e-01 1.76863760 0.07467002 336.25 6.19827865e-02 8.40811834e-01 8.43093356e-01 1.49721164 0.05682279 336.50 3.38979889e-01 7.41385662e-01 8.15205535e-01 1.14195055 0.04613760 336.75 1.81245774e+00 1.01539987e+00 2.07750811e+00 0.51066620 0.17387831 337.00 2.81477943e+00 8.67841350e-01 2.94552743e+00 0.29906852 0.27620726 337.25 3.32441044e+00 -7.29799873e-01 3.40357351e+00 -0.21609968 0.35327554 337.50 3.09557850e+00 -1.21754786e+00 3.32641384e+00 -0.37473310 0.42138198 337.75 3.01043291e+00 -1.27892351e+00 3.27083348e+00 -0.40172701 0.60714228 338.00 3.18357955e+00 -1.51045066e+00 3.52372529e+00 -0.44299984 0.74490247 338.25 3.12449464e+00 -1.70483921e+00 3.55934594e+00 -0.49948716 0.80410115 338.50 3.01856733e+00 -1.70808831e+00 3.46833020e+00 -0.51493865 0.81955404 338.75 2.66779844e+00 -2.21170854e+00 3.46537202e+00 -0.69219847 0.85333534 339.00 2.53015862e+00 -2.44826756e+00 3.52075513e+00 -0.76895046 0.89592781 339.25 2.66830312e+00 -2.52805720e+00 3.67571962e+00 -0.75841545 0.92092044 339.50 2.50107782e+00 -2.47563728e+00 3.51911498e+00 -0.78028629 0.91070380 339.75 2.08161289e+00 -2.41230230e+00 3.18626971e+00 -0.85885181 0.90983724 340.00 1.82861761e+00 -2.33008581e+00 2.96194906e+00 -0.90540160 0.89236860 340.25 1.56121677e+00 -2.27924699e+00 2.76267346e+00 -0.97022871 0.92577280 340.50 1.56509757e+00 -2.20493853e+00 2.70393867e+00 -0.95351371 0.92201296 340.75 1.63238539e+00 -2.11964575e+00 2.67536543e+00 -0.91454115 0.91008910 341.00 1.56181444e+00 -1.97969533e+00 2.52159829e+00 -0.90285021 0.89882357 341.25 1.74851325e+00 -1.88537426e+00 2.57136825e+00 -0.82304279 0.94412737 341.50 1.85017259e+00 -1.90432852e+00 2.65510936e+00 -0.79982143 0.91797862 341.75 2.03565047e+00 -2.00239541e+00 2.85542645e+00 -0.77716292 0.92797961 342.00 2.10579256e+00 -2.09694274e+00 2.97178922e+00 -0.78329244 0.92666966 342.25 2.15323194e+00 -2.20250345e+00 3.08016708e+00 -0.79670955 0.94980164 342.50 2.26978602e+00 -2.31560529e+00 3.24252315e+00 -0.79539028 0.93979361 342.75 2.19200600e+00 -2.50062094e+00 3.32535643e+00 -0.85106951 0.94130482 343.00 2.21608709e+00 -2.67385262e+00 3.47282735e+00 -0.87873987 0.92348256 343.25 2.10980344e+00 -2.81499084e+00 3.51787492e+00 -0.92762262 0.93273853 343.50 1.94150604e+00 -2.74048220e+00 3.35852474e+00 -0.95441893 0.92435315 343.75 1.85429819e+00 -2.51707080e+00 3.12635046e+00 -0.93586888 0.93155944 344.00 2.00244405e+00 -2.38541869e+00 3.11448302e+00 -0.87245799 0.91870781 344.25 2.08441838e+00 -2.41049052e+00 3.18673257e+00 -0.85781386 0.93511044 344.50 2.27005279e+00 -2.52860166e+00 3.39808270e+00 -0.83922557 0.93253541 344.75 2.29566003e+00 -2.72546464e+00 3.56345513e+00 -0.87078928 0.95913423 345.00 2.53015698e+00 -2.81496475e+00 3.78493340e+00 -0.83863151 0.94234177 345.25 2.56069817e+00 -2.81507881e+00 3.80550178e+00 -0.83268268 0.95543541 345.50 2.60992568e+00 -2.71803002e+00 3.76820902e+00 -0.80568540 0.94608757 345.75 2.77048983e+00 -2.84921784e+00 3.97412333e+00 -0.79940652 0.95658599 346.00 3.04063960e+00 -2.89901198e+00 4.20116170e+00 -0.76155825 0.96037912 346.25 3.17412153e+00 -2.91619922e+00 4.31036719e+00 -0.74307391 0.96957926 346.50 3.48782406e+00 -3.03225518e+00 4.62163263e+00 -0.71563986 0.97580278 346.75 3.65318982e+00 -3.10328977e+00 4.79334990e+00 -0.70418861 0.97935233 347.00 3.99959306e+00 -3.21807350e+00 5.13349215e+00 -0.67753967 0.95768583 347.25 4.30240909e+00 -3.20016555e+00 5.36206896e+00 -0.63952632 0.95447956 347.50 4.96461289e+00 -3.28333754e+00 5.95211614e+00 -0.58431151 0.95997893 347.75 5.34503771e+00 -3.40924791e+00 6.33974758e+00 -0.56777522 0.96351567 348.00 6.12830160e+00 -3.54988378e+00 7.08221402e+00 -0.52503035 0.94993283 348.25 6.55640232e+00 -3.94201181e+00 7.65022016e+00 -0.54133530 0.93679097 348.50 7.87003906e+00 -5.22436751e+00 9.44624426e+00 -0.58603614 0.92954377 348.75 8.51520486e+00 -5.98714628e+00 1.04093532e+01 -0.61281178 0.94501429 349.00 8.89472147e+00 -7.13769040e+00 1.14045033e+01 -0.67624135 0.92549298 349.25 8.88791813e+00 -8.45289516e+00 1.22656645e+01 -0.76031677 0.93539791 349.50 8.35684822e+00 -9.96699134e+00 1.30068378e+01 -0.87304453 0.93630918 349.75 7.49555528e+00 -1.07024044e+01 1.30661704e+01 -0.95982758 0.92738223 350.00 6.01028496e+00 -1.18119400e+01 1.32531299e+01 -1.10010865 0.94197229 350.25 5.78380360e+00 -1.25156467e+01 1.37874507e+01 -1.13790444 0.94536103 350.50 5.52479180e+00 -1.31312920e+01 1.42461979e+01 -1.17254386 0.95800528 350.75 5.34287496e+00 -1.29823895e+01 1.40388300e+01 -1.18037468 0.94258590 351.00 5.05954540e+00 -1.32674484e+01 1.41994431e+01 -1.20646993 0.93714908 351.25 4.04499555e+00 -1.42342583e+01 1.47978410e+01 -1.29392197 0.92280872 351.50 2.33119402e+00 -1.55867389e+01 1.57601045e+01 -1.42233413 0.92276539 351.75 6.35194793e-01 -1.49075434e+01 1.49210697e+01 -1.52821313 0.86025118 352.00 -1.08492130e+00 -1.40361193e+01 1.40779863e+01 -1.64793790 0.86615010 352.25 -1.90816731e+00 -1.32740806e+01 1.34105302e+01 -1.71356962 0.83764748 352.50 -3.41244469e+00 -1.19808169e+01 1.24573172e+01 -1.84827428 0.85860804 352.75 -3.57491293e+00 -1.04887214e+01 1.10812129e+01 -1.89928223 0.85835129 353.00 -3.46212299e+00 -9.08064221e+00 9.71824874e+00 -1.93504748 0.89239493 353.25 -3.02544578e+00 -8.58845510e+00 9.10576099e+00 -1.90949102 0.84573041 353.50 -2.89558111e+00 -8.11293014e+00 8.61417585e+00 -1.91361321 0.79144161 353.75 -2.76144193e+00 -6.82195299e+00 7.35966060e+00 -1.95542311 0.67494666 354.00 -3.39795259e+00 -5.94678078e+00 6.84910822e+00 -2.08991609 0.64922217 354.25 -3.33506907e+00 -4.93578995e+00 5.95690425e+00 -2.16502058 0.62212348 354.50 -3.73336894e+00 -4.64506929e+00 5.95942215e+00 -2.24780588 0.65411938 354.75 -3.20626444e+00 -2.06974425e+00 3.81627736e+00 -2.56836525 0.36554647 355.00 -3.20274653e+00 3.08240535e-01 3.21754527e+00 3.04564560 0.35311970 355.25 8.17252973e-01 1.91261575e+00 2.07990419e+00 1.16698259 0.17592018 355.50 4.04942709e+00 2.05831931e+00 4.54252552e+00 0.47026466 0.53408622 355.75 6.15014777e+00 -1.68120434e+00 6.37579529e+00 -0.26684087 0.67314704 356.00 6.24306726e+00 -3.88826710e+00 7.35489700e+00 -0.55702552 0.86417144 356.25 4.57890173e+00 -4.93786153e+00 6.73415307e+00 -0.82309898 0.85086385 356.50 3.23345943e+00 -5.13065851e+00 6.06456236e+00 -1.00844990 0.88391506 356.75 2.36101449e+00 -4.62456262e+00 5.19239529e+00 -1.09875398 0.91793396 357.00 2.05746833e+00 -4.23193991e+00 4.70558088e+00 -1.11826882 0.94907781 357.25 1.63640628e+00 -3.46095263e+00 3.82831799e+00 -1.12912849 0.93457577 357.50 1.68175734e+00 -2.81847933e+00 3.28209285e+00 -1.03281449 0.91821933 357.75 2.64849895e+00 -2.31056148e+00 3.51471777e+00 -0.71735789 0.77314650 358.00 2.39588568e+00 -2.67444067e+00 3.59066861e+00 -0.84028127 0.58668607 358.25 -5.10188831e-01 -2.02811408e+00 2.09130088e+00 -1.81724104 0.53550205 358.50 -4.11896682e-01 -1.45351586e+00 1.51075055e+00 -1.84693614 0.55866550 358.75 9.82164480e-02 -5.51683792e-01 5.60358347e-01 -1.39461190 0.36366291 359.00 2.44636926e-01 -3.03461810e-01 3.89790066e-01 -0.89231424 0.25667372 359.25 6.06669758e-01 3.04139509e-01 6.78637633e-01 0.46470809 0.49745900 359.50 7.57512940e-01 6.43094207e-01 9.93678023e-01 0.70388693 0.73146847 359.75 1.10231245e+00 9.05645553e-01 1.42663472e+00 0.68776583 0.88388960 360.00 1.31758891e+00 9.07687111e-01 1.59998014e+00 0.60323744 0.92593981 360.25 1.57475532e+00 9.33282876e-01 1.83053851e+00 0.53499951 0.95983649 360.50 1.62994823e+00 9.27900973e-01 1.87556164e+00 0.51752680 0.96282511 360.75 1.74891431e+00 8.97130358e-01 1.96559002e+00 0.47396507 0.96465405 361.00 1.85626271e+00 8.91827544e-01 2.05938525e+00 0.44787957 0.96149399 361.25 2.09373292e+00 8.51407488e-01 2.26022394e+00 0.38622227 0.95770756 361.50 2.14351773e+00 5.93280333e-01 2.22410652e+00 0.27001922 0.93268845 361.75 1.99604571e+00 1.27673325e-01 2.00012473e+00 0.06387611 0.89631388 362.00 1.51815422e+00 -1.78529620e-01 1.52861541e+00 -0.11705887 0.78529481 362.25 7.66159056e-01 -1.36409984e-01 7.78207802e-01 -0.17619763 0.65663982 362.50 6.45993423e-01 1.80540832e-01 6.70747713e-01 0.27252442 0.45705477 362.75 4.79463273e-01 7.82445277e-01 9.17663142e-01 1.02103602 0.80988277 363.00 4.81048990e-01 9.56447092e-01 1.07060692e+00 1.10478823 0.83610719 363.25 4.99310930e-01 1.23905751e+00 1.33587983e+00 1.18772673 0.90371479 363.50 6.98093905e-01 1.51358507e+00 1.66681578e+00 1.13865210 0.92383552 363.75 1.02328386e+00 1.62677923e+00 1.92185340e+00 1.00930828 0.95947154 364.00 1.26166615e+00 1.47588197e+00 1.94165626e+00 0.86349001 0.96310421 364.25 1.39509709e+00 1.27314191e+00 1.88869961e+00 0.73972371 0.96655485 364.50 1.19780130e+00 8.99050004e-01 1.49767115e+00 0.64387450 0.88133343 364.75 7.13565983e-01 6.56468291e-01 9.69601479e-01 0.74374616 0.76579129 365.00 4.08911883e-01 1.04061699e+00 1.11807542e+00 1.19638108 0.81460060 365.25 4.19955236e-01 1.38449637e+00 1.44678699e+00 1.27628997 0.94019388 365.50 6.35571927e-01 1.38339689e+00 1.52241211e+00 1.14012940 0.94714579 365.75 7.20692933e-01 1.30927922e+00 1.49452681e+00 1.06760758 0.96748967 366.00 5.26641997e-01 1.16526196e+00 1.27874440e+00 1.14632064 0.89659668 366.25 2.33611857e-01 1.18202275e+00 1.20488683e+00 1.37567356 0.89489229 366.50 -1.19771844e-01 1.45051060e+00 1.45544711e+00 1.65318162 0.91736534 366.75 -1.99050928e-01 1.63291353e+00 1.64500088e+00 1.69209711 0.94637735 367.00 -1.86213324e-01 2.02181867e+00 2.03037586e+00 1.66263911 0.94030015 367.25 -1.72969174e-01 2.27404957e+00 2.28061829e+00 1.64671233 0.94996855 367.50 -8.14076119e-02 2.73704273e+00 2.73825311e+00 1.60053047 0.93538841 367.75 1.00038447e-01 3.05600638e+00 3.05764333e+00 1.53807299 0.93749130 368.00 8.76861586e-01 3.23100903e+00 3.34788076e+00 1.30578996 0.92060850 368.25 1.28704240e+00 3.20722152e+00 3.45582812e+00 1.18917395 0.94385996 368.50 1.33035830e+00 3.18605841e+00 3.45265425e+00 1.17524754 0.94591224 368.75 1.54803231e+00 3.28203064e+00 3.62879169e+00 1.13006924 0.93868216 369.00 2.13012762e+00 3.19720550e+00 3.84181815e+00 0.98308452 0.89418131 369.25 2.64328446e+00 2.70584660e+00 3.78266553e+00 0.79709339 0.88024419 369.50 3.23979671e+00 1.97633821e+00 3.79502245e+00 0.54775401 0.87489230 369.75 3.48614347e+00 1.63566527e+00 3.85079176e+00 0.43869761 0.88993540 370.00 3.13344554e+00 5.52439829e-01 3.18177163e+00 0.17451090 0.84778816 370.25 2.54777393e+00 -7.39642271e-02 2.54884733e+00 -0.02902277 0.84485024 370.50 1.77035259e+00 7.48970019e-02 1.77193618e+00 0.04228105 0.91393829 370.75 1.61759159e+00 1.78112822e-01 1.62736804e+00 0.10966810 0.92177009 371.00 1.38930594e+00 3.50142096e-01 1.43274927e+00 0.24688517 0.94475746 371.25 1.19228189e+00 3.60914343e-01 1.24571074e+00 0.29394017 0.92173599 371.50 9.88554509e-01 4.58859310e-01 1.08985865e+00 0.43457665 0.93001636 371.75 9.05699643e-01 5.89871196e-01 1.08085146e+00 0.57728005 0.91030924 372.00 8.61607207e-01 8.19073593e-01 1.18880130e+00 0.76009619 0.92768087 372.25 9.29231070e-01 9.69208118e-01 1.34269682e+00 0.80645290 0.91772718 372.50 1.26784490e+00 1.08821900e+00 1.67082353e+00 0.70930554 0.93843277 372.75 1.49966421e+00 1.04203055e+00 1.82614907e+00 0.60725621 0.94527270 373.00 1.65243353e+00 8.14040652e-01 1.84206372e+00 0.45773538 0.92752669 373.25 1.53735259e+00 4.81714385e-01 1.61105610e+00 0.30365014 0.92726066 373.50 1.41630488e+00 2.93309626e-01 1.44635752e+00 0.20420825 0.95084138 373.75 1.24019674e+00 1.77070005e-01 1.25277362e+00 0.14181728 0.93692772 374.00 1.08373644e+00 1.15892413e-01 1.08991547e+00 0.10653296 0.95996330 374.25 9.21277620e-01 8.98747663e-02 9.25651082e-01 0.09724677 0.95436831 374.50 7.58978344e-01 1.04463065e-01 7.66133578e-01 0.13677705 0.93197726 374.75 6.29649630e-01 1.78121105e-01 6.54359064e-01 0.27568588 0.87912924 375.00 5.30317113e-01 3.08415949e-01 6.13479125e-01 0.52675698 0.90014197 375.25 4.54291287e-01 4.20418194e-01 6.18976600e-01 0.74669254 0.86954437 375.50 4.24645130e-01 5.46714500e-01 6.92257345e-01 0.91041138 0.89225080 375.75 5.49457540e-01 6.89922917e-01 8.81984818e-01 0.89825177 0.92116894 376.00 7.28543393e-01 8.00811295e-01 1.08262376e+00 0.83261689 0.94289401 376.25 8.88771564e-01 7.02961287e-01 1.13316789e+00 0.66918953 0.95201331 376.50 9.56708312e-01 5.90945392e-01 1.12450311e+00 0.55332256 0.97138834 376.75 9.75573335e-01 5.05042063e-01 1.09854942e+00 0.47769723 0.96487991 377.00 9.80438215e-01 4.54935796e-01 1.08084489e+00 0.43444560 0.96614408 377.25 1.00281279e+00 3.41907496e-01 1.05949716e+00 0.32858846 0.96746000 377.50 1.02137977e+00 2.93186563e-01 1.06262646e+00 0.27953368 0.97210487 377.75 1.01829232e+00 1.77128293e-01 1.03358294e+00 0.17222320 0.96461665 378.00 1.01703784e+00 1.16534924e-01 1.02369251e+00 0.11408514 0.97065720 378.25 9.69305331e-01 -5.34219447e-02 9.70776354e-01 -0.05505794 0.93970048 378.50 9.32327995e-01 -1.58143158e-01 9.45645149e-01 -0.16802256 0.95216757 378.75 8.65460553e-01 -3.23684271e-01 9.24009457e-01 -0.35789572 0.92898585 379.00 8.10384352e-01 -4.60812700e-01 9.32239852e-01 -0.51703746 0.91733691 379.25 6.04692020e-01 -6.55748525e-01 8.91996955e-01 -0.82588290 0.88844582 379.50 4.55544224e-01 -7.17629558e-01 8.50007484e-01 -1.00518781 0.88836724 379.75 1.90482229e-01 -7.71481003e-01 7.94648613e-01 -1.32873307 0.83308443 380.00 6.20231792e-02 -7.20470891e-01 7.23135658e-01 -1.48492105 0.82335187 380.25 -2.98433490e-02 -5.85921469e-01 5.86680998e-01 -1.62168639 0.78693802 380.50 -8.17370469e-02 -5.63734930e-01 5.69629718e-01 -1.71478490 0.77573911 380.75 -5.21049619e-02 -6.28848321e-01 6.31003279e-01 -1.65346524 0.81437829 381.00 -2.26485772e-02 -6.95930620e-01 6.96299063e-01 -1.60332915 0.79430693 381.25 -3.03033939e-02 -9.14808751e-01 9.15310519e-01 -1.60390961 0.85623018 381.50 -9.30152304e-02 -1.08776346e+00 1.09173311e+00 -1.65609935 0.82419415 381.75 -3.78146358e-01 -1.48848740e+00 1.53576998e+00 -1.81958067 0.83757141 382.00 -7.13804336e-01 -1.75632062e+00 1.89583194e+00 -1.95682516 0.78794815 382.25 -1.79273396e+00 -2.22945433e+00 2.86083233e+00 -2.24804037 0.86583548 382.50 -2.57913143e+00 -2.01344270e+00 3.27198265e+00 -2.47875182 0.85885491 382.75 -3.66187591e+00 -1.18858409e+00 3.84994381e+00 -2.82773761 0.88868196 383.00 -4.21933240e+00 -3.28882422e-01 4.23213062e+00 -3.06380339 0.87625642 383.25 -4.55722109e+00 1.20997007e+00 4.71511310e+00 2.88207408 0.90521792 383.50 -4.02561301e+00 2.15206350e+00 4.56474943e+00 2.65065533 0.91807441 383.75 -3.31675115e+00 2.62362602e+00 4.22897762e+00 2.47234959 0.95765594 384.00 -2.81276471e+00 2.75315596e+00 3.93592595e+00 2.36690368 0.95054710 384.25 -2.37106918e+00 2.93563667e+00 3.77358341e+00 2.25020560 0.96798134 384.50 -1.92792201e+00 3.11726784e+00 3.66527517e+00 2.12468273 0.95998759 384.75 -1.48987838e+00 3.33192218e+00 3.64985520e+00 1.99128001 0.97512168 385.00 -1.20881937e+00 3.16579317e+00 3.38872995e+00 1.93554823 0.96574920 385.25 -9.38204367e-01 3.11001872e+00 3.24845253e+00 1.86378601 0.97036007 385.50 -6.74342286e-01 3.03051971e+00 3.10463963e+00 1.78974620 0.95460596 385.75 -5.56449636e-01 3.05387727e+00 3.10415891e+00 1.75102992 0.96773367 386.00 -4.28220938e-01 3.02839406e+00 3.05851986e+00 1.71126704 0.96441431 386.25 -3.21958491e-01 3.08816469e+00 3.10490232e+00 1.67467665 0.96828692 386.50 -9.83877118e-02 3.18111538e+00 3.18263652e+00 1.60171515 0.93796672 386.75 2.79577500e-01 3.34817169e+00 3.35982399e+00 1.48748805 0.94520055 387.00 9.08643294e-01 3.12283258e+00 3.25234007e+00 1.28764654 0.94607940 387.25 1.14659543e+00 2.84390279e+00 3.06634377e+00 1.18755439 0.95720925 387.50 1.33178051e+00 2.46005188e+00 2.79740855e+00 1.07460856 0.94151248 387.75 1.40098948e+00 2.22037142e+00 2.62541821e+00 1.00791494 0.95773879 388.00 1.36910559e+00 1.84983778e+00 2.30138000e+00 0.93364719 0.94467198 388.25 1.35631045e+00 1.68384752e+00 2.16215645e+00 0.89272106 0.95949141 388.50 1.26054115e+00 1.62318105e+00 2.05515954e+00 0.91049559 0.95961469 388.75 1.25663201e+00 1.53221488e+00 1.98161712e+00 0.88389446 0.96102094 389.00 1.27025191e+00 1.36874026e+00 1.86734834e+00 0.82270129 0.95911527 389.25 1.30604260e+00 1.25953155e+00 1.81443297e+00 0.76727124 0.96118049 389.50 1.38966430e+00 1.03367769e+00 1.73195163e+00 0.63954231 0.94015740 389.75 1.37137091e+00 8.70311920e-01 1.62422320e+00 0.56549368 0.94198316 390.00 1.28126806e+00 5.21107128e-01 1.38318490e+00 0.38627918 0.93984459 390.25 1.20050975e+00 3.89864810e-01 1.26222749e+00 0.31400521 0.93459103 390.50 8.12507357e-01 3.17928406e-01 8.72494514e-01 0.37297784 0.85194001 390.75 6.89087209e-01 3.25693352e-01 7.62179337e-01 0.44152479 0.87154400 391.00 5.39709896e-01 3.78458478e-01 6.59179483e-01 0.61154814 0.84892777 391.25 4.34295299e-01 4.09752582e-01 5.97084236e-01 0.75632896 0.80068146 391.50 2.59281189e-01 5.51334857e-01 6.09259272e-01 1.13120697 0.85205425 391.75 2.47015817e-01 5.79501676e-01 6.29951591e-01 1.16786268 0.83750075 392.00 2.45730696e-01 6.57226705e-01 7.01662680e-01 1.21299889 0.87598487 392.25 2.76384602e-01 7.01037995e-01 7.53553395e-01 1.19525619 0.88446754 392.50 3.18430688e-01 6.95905583e-01 7.65299081e-01 1.14165890 0.88594357 392.75 3.19718692e-01 6.52122913e-01 7.26281169e-01 1.11496002 0.87028735 393.00 3.36409671e-01 5.67753886e-01 6.59936317e-01 1.03588959 0.83147172 393.25 3.64529480e-01 5.43751356e-01 6.54635226e-01 0.98021537 0.82306392 393.50 3.84004665e-01 4.28645846e-01 5.75497041e-01 0.84027582 0.79835464 393.75 3.34629765e-01 4.30243110e-01 5.45056156e-01 0.90975861 0.71195347 394.00 2.69312604e-01 5.09674335e-01 5.76452259e-01 1.08468664 0.78675061 394.25 2.25212971e-01 5.40282364e-01 5.85342562e-01 1.17585489 0.78188308 394.50 1.31038842e-01 5.34276622e-01 5.50111522e-01 1.33027998 0.80961416 394.75 1.11254221e-01 6.21625152e-01 6.31502440e-01 1.39369818 0.77357486 395.00 1.66869107e-01 7.92297735e-01 8.09679566e-01 1.36321600 0.80606127 395.25 3.62888035e-01 8.86021807e-01 9.57456197e-01 1.18206719 0.76080815 395.50 7.71498476e-01 7.05061297e-01 1.04514178e+00 0.74043392 0.74144706 395.75 7.86594875e-01 3.26220382e-01 8.51558121e-01 0.39313535 0.63189883 396.00 7.26811870e-01 -1.04987651e-01 7.34355433e-01 -0.14345727 0.55529964 396.25 3.57928161e-01 -3.43330874e-01 4.95972436e-01 -0.76458534 0.38908873 396.50 1.52447002e-01 -4.44641795e-01 4.70049374e-01 -1.24050222 0.50458891 396.75 -4.58708085e-02 -3.26869450e-01 3.30072369e-01 -1.71021957 0.43789967 397.00 -1.24194617e-01 -3.21265996e-01 3.44435979e-01 -1.93967942 0.57844771 397.25 -2.37799711e-01 -4.15639335e-01 4.78857765e-01 -2.09047101 0.56589148 397.50 -4.25040959e-01 -4.83497910e-01 6.43762415e-01 -2.29194134 0.69714584 397.75 -6.62732712e-01 -4.79611865e-01 8.18072239e-01 -2.51514482 0.77324196 398.00 -8.54643233e-01 -3.74211684e-01 9.32978799e-01 -2.72888245 0.84509517 398.25 -1.03193522e+00 -9.39448652e-02 1.03620266e+00 -3.05080535 0.90986097 398.50 -1.07225990e+00 2.89546743e-02 1.07265076e+00 3.11459580 0.92657823 398.75 -9.97604944e-01 2.19653374e-01 1.02150048e+00 2.92486998 0.93725158 399.00 -1.00446768e+00 2.80735301e-01 1.04296100e+00 2.86906005 0.96056737 399.25 -9.63200253e-01 3.99344426e-01 1.04270355e+00 2.74856235 0.94897200 399.50 -9.69637384e-01 4.87198902e-01 1.08515410e+00 2.67598318 0.96391244 399.75 -9.59639526e-01 6.08631987e-01 1.13637182e+00 2.57638369 0.97315774 400.00 -9.49010713e-01 6.20739650e-01 1.13399252e+00 2.56234668 0.97721029 400.25 -9.10969121e-01 6.52000931e-01 1.12025441e+00 2.52039255 0.96926521 400.50 -8.92755779e-01 6.71745394e-01 1.11725322e+00 2.49653160 0.97220669 400.75 -8.78608683e-01 6.77317722e-01 1.10937483e+00 2.48485040 0.96847305 401.00 -9.00216425e-01 7.14596692e-01 1.14936419e+00 2.47064031 0.96746006 401.25 -9.26440325e-01 8.04013853e-01 1.22667435e+00 2.42682498 0.96568662 401.50 -9.21361697e-01 8.83349385e-01 1.27640648e+00 2.37725420 0.95743289 401.75 -8.21796665e-01 1.08079436e+00 1.35774306e+00 2.22089720 0.94668520 402.00 -7.47934222e-01 1.20094548e+00 1.41480587e+00 2.12780328 0.94200857 402.25 -5.01838201e-01 1.33687980e+00 1.42796679e+00 1.92990028 0.94168904 402.50 -3.76679811e-01 1.33178595e+00 1.38403089e+00 1.84643486 0.91592913 402.75 9.89628863e-02 1.00618785e+00 1.01104285e+00 1.47275736 0.74210458 403.00 1.75529211e-01 7.19932763e-01 7.41022056e-01 1.33164883 0.63993452 403.25 5.55912815e-02 2.27975362e-01 2.34655399e-01 1.33161634 0.19929192 403.50 -7.38385890e-02 5.66184379e-02 9.30472177e-02 2.48743442 0.03594092 403.75 -3.65782901e-01 -1.33459340e-01 3.89369395e-01 -2.79174185 0.42002800 404.00 -5.88066626e-01 -1.06199796e-01 5.97579077e-01 -2.96292690 0.53665896 404.25 -1.01473362e+00 7.05137325e-02 1.01718067e+00 3.07221429 0.82808789 404.50 -1.20019861e+00 2.52797098e-01 1.22653295e+00 2.93399773 0.82497284 404.75 -1.47766723e+00 7.20131469e-01 1.64380345e+00 2.68812144 0.88840608 405.00 -1.11583044e+00 1.10834709e+00 1.57273992e+00 2.35955902 0.87444977 405.25 -7.56274432e-01 1.30214799e+00 1.50583545e+00 2.09697100 0.90609698 405.50 -4.22129113e-01 1.12690655e+00 1.20337499e+00 1.92920842 0.77212345 405.75 -5.69529484e-02 7.32507077e-01 7.34717807e-01 1.64839093 0.66167322 406.00 -1.67472117e-01 3.35518856e-01 3.74993083e-01 2.03375865 0.35107331 406.25 -3.82572731e-01 9.62815474e-02 3.94502257e-01 2.89504415 0.57983676 406.50 -6.18560299e-01 4.91994444e-02 6.20513843e-01 3.06222111 0.70826019 406.75 -8.68652206e-01 1.50427309e-02 8.68782446e-01 3.12427706 0.89558590 407.00 -1.03852678e+00 1.26371515e-01 1.04618719e+00 3.02050451 0.91088893 407.25 -1.10730075e+00 2.02186522e-01 1.12560843e+00 2.96098822 0.93870239 407.50 -1.19860208e+00 2.79263933e-01 1.23070520e+00 2.91268506 0.94594736 407.75 -1.24780177e+00 3.27656084e-01 1.29010378e+00 2.88480326 0.95602586 408.00 -1.27067155e+00 3.27683848e-01 1.31224346e+00 2.88920912 0.94765558 408.25 -1.27775873e+00 3.50139759e-01 1.32486422e+00 2.87413172 0.95526981 408.50 -1.28575487e+00 4.72155083e-01 1.36970654e+00 2.78966007 0.92106233 408.75 -1.33703167e+00 5.32996151e-01 1.43935353e+00 2.76225805 0.92268973 409.00 -1.26301401e+00 5.04994769e-01 1.36022943e+00 2.76123019 0.86211430 409.25 -1.36755013e+00 5.56225838e-01 1.47634026e+00 2.75529669 0.90607244 409.50 -1.45560389e+00 6.68129566e-01 1.60161787e+00 2.71127539 0.92287850 409.75 -1.37755854e+00 7.15332088e-01 1.55221375e+00 2.66264400 0.92192252 410.00 -1.26686479e+00 6.52285576e-01 1.42492907e+00 2.66611064 0.87557907 410.25 -1.22742784e+00 6.87683178e-01 1.40694252e+00 2.63090366 0.85563914 410.50 -1.18903919e+00 5.79827669e-01 1.32288107e+00 2.68787872 0.85376484 410.75 -1.23906267e+00 5.03777790e-01 1.33756060e+00 2.75542698 0.89487260 411.00 -1.28038395e+00 4.86476812e-01 1.36968710e+00 2.77849280 0.88568899 411.25 -1.28342452e+00 4.02484818e-01 1.34505484e+00 2.83770391 0.85552792 411.50 -1.55224689e+00 3.35200437e-01 1.58802699e+00 2.92891312 0.88557235 411.75 -1.61067145e+00 2.18908552e-01 1.62547946e+00 3.00650898 0.89379787 412.00 -1.80802239e+00 9.36065543e-02 1.81044391e+00 3.08986594 0.86228614 412.25 -2.00679844e+00 3.48480842e-02 2.00710099e+00 3.12422938 0.87140891 412.50 -2.54469482e+00 -1.92240416e-01 2.55194594e+00 -3.06619031 0.87250628 412.75 -3.00531728e+00 -4.84609311e-02 3.00570797e+00 -3.12546899 0.85449611 413.00 -3.53450544e+00 3.70851122e-01 3.55390760e+00 3.03705210 0.84599278 413.25 -3.64245035e+00 6.77434402e-01 3.70491051e+00 2.95771044 0.81221308 413.50 -3.53389500e+00 1.91644242e+00 4.02009520e+00 2.64467792 0.83548210 413.75 -3.77790344e+00 2.05882173e+00 4.30247618e+00 2.64262400 0.83824343 414.00 -4.23817555e+00 2.26167383e+00 4.80388389e+00 2.65139406 0.84497718 414.25 -4.73507512e+00 2.44451437e+00 5.32884480e+00 2.66502441 0.75542856 414.50 -5.43748906e+00 4.06884546e+00 6.79130257e+00 2.49918369 0.64329816 414.75 -2.18632598e+00 5.26788163e+00 5.70356013e+00 1.96419161 0.34920228 415.00 3.08683138e+00 7.32622579e+00 7.94997561e+00 1.17202988 0.57567576 415.25 4.92049355e+00 5.15793661e+00 7.12850383e+00 0.80895333 0.68090774 415.50 5.93406190e+00 3.97379029e+00 7.14171547e+00 0.59007047 0.82601018 415.75 5.77723611e+00 2.60963688e+00 6.33929505e+00 0.42427528 0.81636698 416.00 5.02810033e+00 1.23459698e+00 5.17745330e+00 0.24077611 0.83095530 416.25 4.35900532e+00 1.29990159e-01 4.36094311e+00 0.02981222 0.77511880 416.50 3.31263300e+00 -1.03793600e+00 3.47143321e+00 -0.30363774 0.77705461 416.75 2.27617605e+00 -1.06526749e+00 2.51312002e+00 -0.43772765 0.66282809 417.00 1.91727469e+00 -9.54695392e-01 2.14181828e+00 -0.46200144 0.66097837 417.25 1.68068438e+00 -1.20021485e+00 2.06523986e+00 -0.62014153 0.58188331 417.50 1.52825704e+00 -1.41456462e+00 2.08244151e+00 -0.74678355 0.70874595 417.75 1.62128339e+00 -1.80488394e+00 2.42614218e+00 -0.83893469 0.68930325 418.00 1.67031365e+00 -2.30063089e+00 2.84303538e+00 -0.94281714 0.73573301 418.25 1.31809982e+00 -3.00233600e+00 3.27893406e+00 -1.15710681 0.66968433 418.50 7.17075326e-01 -3.64587073e+00 3.71571936e+00 -1.37659366 0.74125702 418.75 7.29938633e-02 -3.91291454e+00 3.91359532e+00 -1.55214389 0.66145265 419.00 -3.49767529e-01 -4.38828668e+00 4.40220369e+00 -1.65033299 0.67073738 419.25 -1.75054339e+00 -4.90942607e+00 5.21218443e+00 -1.91331019 0.48993403 419.50 -3.43614529e+00 -4.21491103e+00 5.43806670e+00 -2.25475844 0.38678092 419.75 -2.79652515e+00 -1.89978743e+00 3.38079061e+00 -2.54486842 0.10626229 420.00 -2.50326834e+00 1.52135203e+00 2.92931125e+00 2.59549681 0.09222048 420.25 -1.85687884e+00 6.11439966e+00 6.39013945e+00 1.86563452 0.52060856 420.50 -1.66437168e+00 7.37213417e+00 7.55767790e+00 1.79283902 0.64056888 420.75 1.51760731e+00 7.75848218e+00 7.90551565e+00 1.37762911 0.58388017 421.00 3.95049137e+00 7.58454260e+00 8.55170559e+00 1.09059965 0.63662908 421.25 8.62107294e+00 5.71816989e+00 1.03450648e+01 0.58565308 0.72948638 421.50 1.02848026e+01 3.75935421e+00 1.09503382e+01 0.35043821 0.77420910 421.75 1.27558846e+01 -3.83768827e-01 1.27616563e+01 -0.03007656 0.81575903 422.00 1.23253099e+01 -2.27014399e+00 1.25326301e+01 -0.18214415 0.84097684 422.25 1.09010792e+01 -3.98834257e+00 1.16077735e+01 -0.35073951 0.90924064 422.50 1.17192232e+01 -3.80857708e+00 1.23225586e+01 -0.31421874 0.93074169 422.75 1.35111149e+01 -2.80748049e+00 1.37997164e+01 -0.20487502 0.92648488 423.00 1.45870928e+01 -1.78211615e+00 1.46955508e+01 -0.12156831 0.88043145 423.25 1.85004542e+01 2.10553443e+00 1.86198840e+01 0.11332228 0.89374917 423.50 1.90490949e+01 3.98226757e+00 1.94608959e+01 0.20608488 0.85142975 423.75 2.27484836e+01 1.10159728e+01 2.52753865e+01 0.45096910 0.84319272 424.00 2.31749614e+01 1.49864536e+01 2.75984172e+01 0.57402771 0.85260258 424.25 1.83288309e+01 1.93359809e+01 2.66425637e+01 0.81213160 0.86328637 424.50 1.34880188e+01 2.06752073e+01 2.46858431e+01 0.99275229 0.84844981 424.75 9.63022040e+00 2.29292908e+01 2.48695300e+01 1.17317137 0.88882430 425.00 8.02347444e+00 2.57324741e+01 2.69543385e+01 1.26854616 0.91408395 425.25 6.16881028e+00 3.03486629e+01 3.09692680e+01 1.37026366 0.92062586 425.50 6.36907753e+00 2.94270363e+01 3.01083978e+01 1.35764778 0.89423227 425.75 8.83092917e+00 2.83567388e+01 2.96999991e+01 1.26889331 0.91617545 426.00 9.98734225e+00 2.78444235e+01 2.95813949e+01 1.22640647 0.87400484 426.25 1.18056296e+01 2.83634721e+01 3.07222954e+01 1.17638029 0.87811208 426.50 1.84666297e+01 2.45041054e+01 3.06833439e+01 0.92498645 0.87251994 426.75 2.15232597e+01 1.99486699e+01 2.93462116e+01 0.74744879 0.91205118 427.00 2.17802762e+01 1.41615890e+01 2.59794349e+01 0.57651753 0.88048271 427.25 2.24032382e+01 1.06582625e+01 2.48093458e+01 0.44405725 0.92255745 427.50 2.01464871e+01 6.13860960e+00 2.10609465e+01 0.29576199 0.92199869 427.75 1.83194936e+01 3.38265986e+00 1.86291769e+01 0.18259150 0.93881189 428.00 1.40514685e+01 3.34283007e-01 1.40554442e+01 0.02378541 0.88060469 428.25 1.10968053e+01 -9.38500638e-01 1.11364210e+01 -0.08437316 0.92891521 428.50 8.11673332e+00 -1.49758606e+00 8.25373393e+00 -0.18245408 0.86835797 428.75 6.02575460e+00 -1.55775134e+00 6.22384991e+00 -0.25297711 0.86693208 429.00 3.23126575e+00 6.70597345e-02 3.23196153e+00 0.02075042 0.56452057 429.25 1.51040227e+00 9.33394327e-01 1.77553936e+00 0.55353334 0.42444142 429.50 4.45895201e-01 2.62004655e+00 2.65771828e+00 1.40222541 0.55761371 429.75 4.76864836e-01 4.60795217e+00 4.63256120e+00 1.46767604 0.82688407 430.00 1.23311567e+00 5.81334929e+00 5.94269335e+00 1.36177652 0.85046420 430.25 2.39603713e+00 6.15117204e+00 6.60135678e+00 1.19935235 0.88619009 430.50 3.25246933e+00 5.44808322e+00 6.34509004e+00 1.03259055 0.87455811 430.75 2.94238574e+00 4.93025896e+00 5.74152308e+00 1.03273202 0.88020519 431.00 2.49646413e+00 4.63734681e+00 5.26662307e+00 1.07695004 0.85369530 431.25 1.75698471e+00 4.64406358e+00 4.96531186e+00 1.20911013 0.81717407 431.50 8.53631942e-01 6.56711820e+00 6.62236581e+00 1.44153531 0.82667728 431.75 5.83867181e-01 7.29673684e+00 7.32005939e+00 1.49094888 0.85967079 432.00 1.96172476e+00 1.00547135e+01 1.02442973e+01 1.37811191 0.85142128 432.25 3.56729149e+00 1.00233255e+01 1.06392022e+01 1.22887597 0.82552880 432.50 7.72905536e+00 8.05789116e+00 1.11654783e+01 0.80622475 0.86000521 432.75 8.89172993e+00 6.76715403e+00 1.11739534e+01 0.65054301 0.86312897 433.00 8.24282914e+00 3.33959535e+00 8.89365669e+00 0.38493950 0.90884204 433.25 7.46474083e+00 2.85640797e+00 7.99258545e+00 0.36546350 0.92580983 433.50 6.12296035e+00 1.83502035e+00 6.39202184e+00 0.29117692 0.92138804 433.75 5.59133376e+00 1.76267900e+00 5.86259758e+00 0.30539004 0.92051476 434.00 4.07923012e+00 2.15784964e+00 4.61480589e+00 0.48656547 0.89412766 434.25 3.27164980e+00 2.34459575e+00 4.02502442e+00 0.62180680 0.86761298 434.50 2.21965391e+00 3.00348535e+00 3.73467372e+00 0.93435562 0.78716635 434.75 1.75130214e+00 3.51992593e+00 3.93153122e+00 1.10911907 0.74439582 435.00 1.29460837e+00 5.13310275e+00 5.29384120e+00 1.32374085 0.79502517 435.25 1.12671663e+00 5.89844045e+00 6.00508868e+00 1.38205067 0.77599075 435.50 2.09797983e-01 6.78967564e+00 6.79291620e+00 1.53990660 0.66715281 435.75 1.80051598e+00 8.78772818e+00 8.97028563e+00 1.36870348 0.53336717 436.00 4.21423145e+00 4.61492839e+00 6.24958484e+00 0.83075040 0.22470601 436.25 2.47647086e+00 -1.58803069e+00 2.94189554e+00 -0.57019768 0.09999285 436.50 1.06702656e+00 -1.70138248e+00 2.00829480e+00 -1.01065052 0.14545651 436.75 5.06744904e-01 2.96678277e-02 5.07612626e-01 0.05847913 0.01414533 437.00 -2.52332770e-01 1.49809752e+00 1.51919979e+00 1.73766551 0.19186036 437.25 -3.71336795e-01 3.09135084e+00 3.11357368e+00 1.69034474 0.47052837 437.50 -5.52505112e-01 5.12471192e+00 5.15440920e+00 1.67819344 0.75231087 437.75 -1.17456872e-01 5.81900398e+00 5.82018930e+00 1.59097863 0.76037382 438.00 6.50295503e-01 6.48161115e+00 6.51415132e+00 1.47080165 0.73304047 438.25 1.85818489e+00 6.77860358e+00 7.02867822e+00 1.30324375 0.76340219 438.50 2.46492437e+00 6.84169462e+00 7.27218244e+00 1.22499307 0.82159559 438.75 2.43109376e+00 6.57091840e+00 7.00622476e+00 1.21643596 0.75984592 439.00 2.88071371e+00 6.78294959e+00 7.36932267e+00 1.16918043 0.70516097 439.25 2.75940431e+00 7.07290755e+00 7.59212311e+00 1.19882118 0.69121849 439.50 2.34424228e+00 8.63208190e+00 8.94473643e+00 1.30561875 0.78855452 439.75 7.62802696e-01 1.05525662e+01 1.05801002e+01 1.49863585 0.74246943 440.00 -5.67487687e-01 1.18269004e+01 1.18405074e+01 1.61874234 0.70627825 440.25 -2.64269640e+00 1.07363925e+01 1.10568516e+01 1.81214234 0.52992801 440.50 -6.50315699e+00 7.91027967e+00 1.02402918e+01 2.25887712 0.43536064 440.75 -9.19553904e+00 7.52475216e-02 9.19584691e+00 3.13340979 0.44471866 441.00 -8.29208704e+00 -4.87083530e+00 9.61684688e+00 -2.61048370 0.57519885 441.25 -4.72276107e+00 -6.47724340e+00 8.01618078e+00 -2.20080716 0.75004324 441.50 -2.84158323e+00 -6.45476929e+00 7.05256278e+00 -1.98549590 0.79495446 441.75 -1.11523093e+00 -6.42846494e+00 6.52448477e+00 -1.74256993 0.74794210 442.00 -7.99846901e-01 -6.35843014e+00 6.40854031e+00 -1.69593218 0.70485273 442.25 1.34348051e-01 -6.09135453e+00 6.09283590e+00 -1.54874437 0.73635942 442.50 6.93466364e-01 -6.17249281e+00 6.21132539e+00 -1.45891760 0.79816753 442.75 -1.46628747e+00 -5.90960574e+00 6.08879619e+00 -1.81400417 0.71846171 443.00 -2.09002486e+00 -5.29492308e+00 5.69248753e+00 -1.94674480 0.78802710 443.25 -1.44293096e+00 -4.46133717e+00 4.68887823e+00 -1.88360770 0.87635209 443.50 -9.65180527e-01 -4.07780922e+00 4.19047747e+00 -1.80321013 0.87798104 443.75 -4.37648139e-01 -4.29641718e+00 4.31864984e+00 -1.67230970 0.83192831 444.00 -3.80290574e-01 -4.25944223e+00 4.27638505e+00 -1.65984200 0.81346848 444.25 -1.13982136e+00 -4.19736557e+00 4.34937587e+00 -1.83595821 0.83240214 444.50 -1.62506252e+00 -3.70780258e+00 4.04828707e+00 -1.98386281 0.78554407 444.75 -2.08403090e+00 -2.00145307e+00 2.88946348e+00 -2.37640423 0.72891904 445.00 -1.35697574e+00 -1.72149257e+00 2.19201273e+00 -2.23833476 0.65165949 445.25 -5.88586809e-01 -1.59364141e+00 1.69886061e+00 -1.92459079 0.68297596 445.50 -2.36673682e-01 -1.59385173e+00 1.61132796e+00 -1.71821079 0.60705913 445.75 1.73939149e-01 -1.49656438e+00 1.50663857e+00 -1.45508983 0.64740290 446.00 3.77577502e-01 -1.76533497e+00 1.80526240e+00 -1.36008678 0.69043540 446.25 7.34181760e-01 -2.22268771e+00 2.34080403e+00 -1.25176689 0.84261394 446.50 5.53950857e-01 -2.52075842e+00 2.58090770e+00 -1.35447912 0.84770394 446.75 -1.61226998e-02 -3.10548419e+00 3.10552605e+00 -1.57598797 0.90587011 447.00 -3.20356578e-01 -3.34163650e+00 3.35695738e+00 -1.66637241 0.88523538 447.25 -1.00709181e+00 -3.40313901e+00 3.54902649e+00 -1.85851525 0.88621917 447.50 -1.70104455e+00 -3.13704327e+00 3.56855615e+00 -2.06766575 0.87957440 447.75 -2.50934550e+00 -2.68423149e+00 3.67449500e+00 -2.32253369 0.91293781 448.00 -2.99814627e+00 -2.07557256e+00 3.64648906e+00 -2.53606314 0.86869740 448.25 -3.08423183e+00 -9.76757141e-01 3.23520331e+00 -2.83489166 0.83525395 448.50 -2.48759426e+00 2.83842781e-01 2.50373559e+00 3.02798069 0.76023177 448.75 -1.98284992e+00 7.65574052e-01 2.12551110e+00 2.77312805 0.82840649 449.00 -1.41270408e+00 8.67843558e-01 1.65797625e+00 2.59071476 0.75445825 449.25 -9.52398285e-01 7.85713246e-01 1.23466910e+00 2.45180219 0.71448695 449.50 -7.51263695e-01 7.96209530e-01 1.09469026e+00 2.32715799 0.64512016 449.75 -4.68064065e-01 6.28924702e-01 7.83983577e-01 2.21059382 0.49589086 450.00 -2.42573974e-01 5.88902585e-01 6.36905321e-01 1.96152630 0.37769834 450.25 -2.39983525e-01 6.28490896e-01 6.72750250e-01 1.93555096 0.54826289 450.50 -1.97110630e-01 6.95063370e-01 7.22471930e-01 1.84712774 0.57723843 450.75 -5.99818443e-02 7.42698650e-01 7.45116840e-01 1.65138344 0.63305652 451.00 1.86315745e-01 5.35446179e-01 5.66935770e-01 1.23593688 0.47010647 451.25 2.60949714e-01 5.38513256e-01 5.98407286e-01 1.11956521 0.51902986 451.50 3.56181049e-01 6.70012975e-01 7.58803220e-01 1.08218695 0.62162468 451.75 4.85390608e-01 6.77755849e-01 8.33640830e-01 0.94929810 0.68636238 452.00 6.87204553e-01 5.77866832e-01 8.97875366e-01 0.69918430 0.55336425 452.25 9.53875916e-01 5.36050777e-01 1.09417992e+00 0.51198766 0.55833945 452.50 1.06979371e+00 5.03882177e-01 1.18252096e+00 0.44018679 0.71645315 452.75 1.24823536e+00 5.16277827e-01 1.35079026e+00 0.39218051 0.77100929 453.00 1.46384407e+00 5.13603178e-01 1.55133094e+00 0.33744006 0.67180577 453.25 1.58103134e+00 5.67426512e-01 1.67977169e+00 0.34457829 0.66535254 453.50 2.36378811e+00 6.63848821e-01 2.45523716e+00 0.27378847 0.71904078 453.75 2.83210839e+00 5.96723684e-01 2.89429043e+00 0.20766201 0.74556009 454.00 3.62342710e+00 2.76078612e-01 3.63392947e+00 0.07604575 0.74441226 454.25 4.19013295e+00 -5.18156826e-01 4.22204934e+00 -0.12303656 0.69827188 454.50 5.01469236e+00 -3.02454655e+00 5.85619512e+00 -0.54272293 0.52805688 454.75 2.53080986e+00 -5.98961125e+00 6.50234123e+00 -1.17101690 0.56721965 455.00 1.36126266e+00 -8.10496590e+00 8.21848576e+00 -1.40439522 0.85591231 455.25 -1.52789296e-01 -7.82118297e+00 7.82267522e+00 -1.59032916 0.85264590 455.50 -2.33934555e+00 -6.32785053e+00 6.74642350e+00 -1.92490389 0.87445459 455.75 -2.86298751e+00 -5.64830446e+00 6.33245930e+00 -2.03992925 0.81864201 456.00 -3.45128715e+00 -4.46818901e+00 5.64589196e+00 -2.22848811 0.87600202 456.25 -3.50912949e+00 -4.27003163e+00 5.52694852e+00 -2.25869177 0.87908633 456.50 -3.53520077e+00 -3.82685458e+00 5.20984266e+00 -2.31659938 0.91312245 456.75 -3.93640500e+00 -3.84020404e+00 5.49931372e+00 -2.36856441 0.90118485 457.00 -4.34230480e+00 -4.04017482e+00 5.93115702e+00 -2.39222193 0.90642151 457.25 -4.78714961e+00 -3.55237812e+00 5.96122401e+00 -2.50318906 0.86343188 457.50 -5.65122559e+00 -2.56768480e+00 6.20720194e+00 -2.71511976 0.89705039 457.75 -5.85332869e+00 -1.66603650e+00 6.08581419e+00 -2.86429517 0.89797777 458.00 -6.02672303e+00 -1.14631277e+00 6.13477167e+00 -2.95363287 0.94196694 458.25 -5.74139663e+00 -4.04474828e-01 5.75562639e+00 -3.07126000 0.93293009 458.50 -5.70412095e+00 1.95484592e-01 5.70746967e+00 3.10733530 0.96675285 458.75 -5.32374851e+00 6.57257006e-01 5.36416676e+00 3.01875666 0.94338600 459.00 -4.89453470e+00 1.00666765e+00 4.99698406e+00 2.93874946 0.94083554 459.25 -4.37897885e+00 1.15017951e+00 4.52751241e+00 2.88473530 0.92316685 459.50 -4.15715111e+00 1.13648044e+00 4.30969757e+00 2.87473351 0.94967619 459.75 -3.85471464e+00 1.23076401e+00 4.04643115e+00 2.83253573 0.94277313 460.00 -3.67040834e+00 1.41240751e+00 3.93278430e+00 2.77424985 0.94991571 460.25 -3.80875409e+00 1.23087058e+00 4.00270535e+00 2.82901788 0.93942630 460.50 -3.98831426e+00 1.21467353e+00 4.16918246e+00 2.84595935 0.94702584 460.75 -3.91092830e+00 1.62928691e+00 4.23673648e+00 2.74685961 0.89347126 461.00 -3.91429568e+00 1.67160310e+00 4.25628565e+00 2.73798624 0.91043094 461.25 -3.84654329e+00 1.86325200e+00 4.27406169e+00 2.69050561 0.87376423 461.50 -3.77504857e+00 2.23122053e+00 4.38512677e+00 2.60778433 0.88592858 461.75 -3.99766992e+00 3.05125726e+00 5.02906906e+00 2.48965969 0.86613427 462.00 -3.57322974e+00 3.64728125e+00 5.10594078e+00 2.34593913 0.85635498 462.25 -1.94568065e+00 3.57339393e+00 4.06876116e+00 2.06940010 0.83079795 462.50 -1.88801377e+00 3.24866487e+00 3.75744852e+00 2.09725222 0.84059050 462.75 -1.65628578e+00 3.02906070e+00 3.45231680e+00 2.07117823 0.87355525 463.00 -1.81074546e+00 2.84604239e+00 3.37324123e+00 2.13743240 0.86502885 463.25 -1.89968101e+00 2.56106103e+00 3.18870217e+00 2.20900002 0.81213415 463.50 -2.14753766e+00 2.82238129e+00 3.54651296e+00 2.22123426 0.86729721 463.75 -2.08595821e+00 2.90127792e+00 3.57332272e+00 2.19414671 0.89105249 464.00 -2.13151343e+00 3.03741699e+00 3.71069421e+00 2.18269716 0.88888561 464.25 -1.83976567e+00 3.56760173e+00 4.01404034e+00 2.04691460 0.89933919 464.50 -1.57198711e+00 3.67612742e+00 3.99813160e+00 1.97488439 0.90146242 464.75 -1.12137030e+00 3.86266649e+00 4.02214666e+00 1.85333958 0.89244499 465.00 -7.90153130e-01 3.80376514e+00 3.88496734e+00 1.77561265 0.83755944 465.25 -3.11256593e-02 2.86063334e+00 2.86080267e+00 1.58167659 0.75098586 465.50 -7.43076092e-02 2.25936311e+00 2.26058472e+00 1.60367322 0.68372472 465.75 -1.82775623e-01 1.86625753e+00 1.87518641e+00 1.66842197 0.66973249 466.00 -3.78992402e-01 1.71021593e+00 1.75170596e+00 1.78887702 0.69890212 466.25 -5.60071383e-01 1.36635778e+00 1.47669006e+00 1.95980878 0.72214976 466.50 -9.55635421e-01 1.11936745e+00 1.47180928e+00 2.27745075 0.65091358 466.75 -1.43488507e+00 8.97220216e-01 1.69230590e+00 2.58278436 0.75820708 467.00 -2.00890572e+00 1.20765167e+00 2.34395494e+00 2.60032873 0.82554774 467.25 -2.70189874e+00 1.48719374e+00 3.08415337e+00 2.63842289 0.94730055 467.50 -2.77688814e+00 1.92831401e+00 3.38075475e+00 2.53462455 0.95383237 467.75 -2.88418413e+00 2.29443807e+00 3.68550731e+00 2.46958687 0.96523588 468.00 -2.96755659e+00 2.54563628e+00 3.90981536e+00 2.43257482 0.96753912 468.25 -3.04008159e+00 2.83841238e+00 4.15916829e+00 2.39048731 0.97586875 468.50 -3.17981566e+00 3.18358409e+00 4.49960390e+00 2.35560229 0.97419683 468.75 -3.33728109e+00 3.52961270e+00 4.85753136e+00 2.32819328 0.98120533 469.00 -3.41189646e+00 3.75233116e+00 5.07159014e+00 2.30871152 0.97442727 469.25 -3.34591492e+00 3.93404905e+00 5.16448338e+00 2.27558151 0.97547776 469.50 -3.58898420e+00 4.38037591e+00 5.66290568e+00 2.25721470 0.96781452 469.75 -3.71773330e+00 4.86067407e+00 6.11945204e+00 2.22373996 0.97331785 470.00 -3.62614161e+00 5.47444849e+00 6.56646703e+00 2.15582237 0.97200865 470.25 -3.54028053e+00 5.85780765e+00 6.84452312e+00 2.11442253 0.97972576 470.50 -3.43235957e+00 6.66247083e+00 7.49463874e+00 2.04651262 0.96705031 470.75 -3.47633036e+00 7.27217626e+00 8.06036106e+00 2.01671530 0.97913270 471.00 -2.91140030e+00 7.84133101e+00 8.36437229e+00 1.92630959 0.96172455 471.25 -2.41012301e+00 8.56317234e+00 8.89587621e+00 1.84515107 0.96097236 471.50 -1.88055996e+00 9.86480504e+00 1.00424541e+01 1.75916940 0.96433232 471.75 -1.20537158e+00 1.04195795e+01 1.04890685e+01 1.68596770 0.97374487 472.00 -2.73424285e-01 1.11534837e+01 1.11568346e+01 1.59530612 0.97116669 472.25 5.41514023e-01 1.13643943e+01 1.13772886e+01 1.52318229 0.97023785 472.50 2.29565719e+00 1.20702182e+01 1.22865866e+01 1.38284922 0.97430077 472.75 3.30300191e+00 1.26086773e+01 1.30341307e+01 1.31459082 0.97981079 473.00 5.33394578e+00 1.27613512e+01 1.38312350e+01 1.17488960 0.97147462 473.25 6.60723210e+00 1.23522792e+01 1.40083659e+01 1.07962020 0.96503416 473.50 8.45814656e+00 1.13915019e+01 1.41882542e+01 0.93211499 0.96315696 473.75 9.24552254e+00 1.11766921e+01 1.45051071e+01 0.87968001 0.96753855 474.00 1.16175336e+01 1.00104692e+01 1.53354681e+01 0.71122966 0.95832718 474.25 1.21951180e+01 8.79541704e+00 1.50359657e+01 0.62482898 0.96972822 474.50 1.25909396e+01 7.08382864e+00 1.44468816e+01 0.51247544 0.96861938 474.75 1.28654355e+01 6.01290042e+00 1.42012113e+01 0.43720340 0.96274067 475.00 1.25592131e+01 4.79156441e+00 1.34422068e+01 0.36447270 0.95683883 475.25 1.21609486e+01 3.70571760e+00 1.27130254e+01 0.29578393 0.94968475 475.50 1.23928801e+01 1.77490293e+00 1.25193353e+01 0.14225221 0.93801586 475.75 1.27486724e+01 1.10600047e+00 1.27965575e+01 0.08653750 0.93027893 476.00 1.37027980e+01 -6.06765407e-01 1.37162253e+01 -0.04425150 0.93999536 476.25 1.34879588e+01 -1.57663599e+00 1.35797943e+01 -0.11636404 0.91650635 476.50 1.27229437e+01 -3.14406923e+00 1.31056655e+01 -0.24226442 0.84643021 476.75 1.19490408e+01 -3.44019364e+00 1.24344083e+01 -0.28032425 0.85360724 477.00 1.02146068e+01 -4.94918185e+00 1.13504446e+01 -0.45118714 0.85568746 477.25 9.14144648e+00 -5.32657127e+00 1.05800948e+01 -0.52758956 0.82908431 477.50 8.40888524e+00 -5.90403673e+00 1.02745803e+01 -0.61214659 0.87365363 477.75 7.30246253e+00 -6.30423528e+00 9.64724528e+00 -0.71216642 0.87712295 478.00 6.02642114e+00 -6.04141836e+00 8.53325773e+00 -0.78664091 0.89968088 478.25 5.78539029e+00 -5.30598260e+00 7.85010778e+00 -0.74220157 0.87747307 478.50 5.59596315e+00 -5.14208868e+00 7.59972891e+00 -0.74315545 0.89651813 478.75 5.75995463e+00 -5.41602127e+00 7.90634958e+00 -0.75463353 0.91978115 479.00 6.07306148e+00 -5.78826211e+00 8.38963968e+00 -0.76139202 0.93935941 479.25 6.04364882e+00 -6.57557313e+00 8.93106114e+00 -0.82752514 0.93464619 479.50 5.81621006e+00 -7.29429679e+00 9.32925855e+00 -0.89766474 0.94605875 479.75 4.70017601e+00 -7.95696572e+00 9.24148029e+00 -1.03724347 0.95487419 480.00 3.99934297e+00 -8.18463513e+00 9.10950034e+00 -1.11627767 0.96888732 480.25 3.28473776e+00 -8.67897791e+00 9.27977153e+00 -1.20898644 0.96742997 480.50 2.67514772e+00 -9.02545908e+00 9.41357142e+00 -1.28264538 0.96348747 480.75 1.13172910e+00 -9.05851902e+00 9.12894176e+00 -1.44650500 0.93437231 481.00 1.45974285e-01 -9.01387653e+00 9.01505843e+00 -1.55460335 0.92931266 481.25 -1.65151540e+00 -8.80118763e+00 8.95479798e+00 -1.75628616 0.90413603 481.50 -2.63213672e+00 -8.94629416e+00 9.32546636e+00 -1.85693765 0.88058124 481.75 -4.34535599e+00 -6.65438493e+00 7.94751266e+00 -2.14928211 0.81106606 482.00 -4.57947337e+00 -4.87597084e+00 6.68929503e+00 -2.32484743 0.79797611 482.25 -2.96532793e+00 -3.67687140e+00 4.72361652e+00 -2.24947679 0.77884584 482.50 -2.41528471e+00 -3.60300483e+00 4.33765421e+00 -2.16134659 0.76766450 482.75 -1.22906425e+00 -4.95575487e+00 5.10588928e+00 -1.81389879 0.76138314 483.00 -1.19584401e+00 -6.38831952e+00 6.49928220e+00 -1.75584698 0.83622676 483.25 -3.82431151e+00 -7.16536279e+00 8.12205531e+00 -2.06105617 0.64602096 483.50 -7.66765070e+00 -5.97706107e+00 9.72204332e+00 -2.47946697 0.66159268 483.75 -8.64049585e+00 -4.26354087e+00 9.63514137e+00 -2.68320917 0.62765732 484.00 -8.48956083e+00 -1.96439537e+00 8.71386781e+00 -2.91420496 0.44865240 484.25 -4.18131802e+00 6.96235234e+00 8.12143894e+00 2.11162830 0.28943134 484.50 -2.22722168e-01 8.31439658e+00 8.31737914e+00 1.59757745 0.35864363 484.75 2.89845205e+00 5.50459086e+00 6.22105657e+00 1.08613362 0.56368762 485.00 3.02063399e+00 4.42868345e+00 5.36073379e+00 0.97221143 0.65597162 485.25 3.12508863e+00 4.27277528e+00 5.29365540e+00 0.93930881 0.75580913 485.50 3.61310829e+00 4.09661460e+00 5.46230745e+00 0.84802998 0.75018256 485.75 5.92428319e+00 3.36280502e+00 6.81216478e+00 0.51627842 0.71294195 486.00 6.41064426e+00 1.28929065e+00 6.53900835e+00 0.19846953 0.61180634 486.25 5.24609068e+00 -3.89700581e+00 6.53514512e+00 -0.63890291 0.60591666 486.50 2.90539223e+00 -5.00901891e+00 5.79064542e+00 -1.04518844 0.58650800 486.75 1.15857628e-01 -4.81782510e+00 4.81921795e+00 -1.54675326 0.70763908 487.00 -5.42563535e-01 -3.92293672e+00 3.96027874e+00 -1.70822991 0.69967039 487.25 -1.29525904e+00 -2.60061330e+00 2.90532021e+00 -2.03288998 0.68977638 487.50 -1.69065783e+00 -1.72446644e+00 2.41497586e+00 -2.34629514 0.58353883 487.75 -1.67959968e+00 -9.95272477e-01 1.95233767e+00 -2.60665778 0.63450322 488.00 -1.36280563e+00 -6.84720947e-01 1.52514982e+00 -2.67599912 0.58808735 488.25 -8.53873857e-01 -4.21176909e-01 9.52097974e-01 -2.68335619 0.44713791 488.50 -4.93599679e-01 -3.38899863e-01 5.98743485e-01 -2.53992452 0.27253186 488.75 -2.24180396e-01 -4.13544908e-01 4.70400087e-01 -2.06754976 0.26000036 489.00 -1.34489887e-01 -5.53112359e-01 5.69228259e-01 -1.80931867 0.33921959 489.25 -8.68340968e-02 -7.35258108e-01 7.40367913e-01 -1.68835196 0.58081889 489.50 -1.76269226e-02 -8.73210741e-01 8.73388635e-01 -1.59097992 0.62803666 489.75 1.29967128e-02 -1.02218623e+00 1.02226885e+00 -1.55808239 0.68392812 490.00 -9.47014406e-02 -1.13977190e+00 1.14369941e+00 -1.65369398 0.70123953 490.25 -1.75177613e-01 -1.32554510e+00 1.33707031e+00 -1.70219008 0.80782897 490.50 -3.20273600e-01 -1.53186874e+00 1.56499106e+00 -1.77690126 0.80885336 490.75 -4.87471908e-01 -1.67063216e+00 1.74029902e+00 -1.85470307 0.85878998 491.00 -7.89235055e-01 -1.56508444e+00 1.75282094e+00 -2.03785915 0.81068054 491.25 -1.13988092e+00 -1.52791328e+00 1.90626533e+00 -2.21175674 0.86325529 491.50 -1.45771524e+00 -1.40735542e+00 2.02622383e+00 -2.37376985 0.88851572 491.75 -1.66771258e+00 -1.33858106e+00 2.13847247e+00 -2.46524103 0.91691523 492.00 -1.80353546e+00 -1.05606190e+00 2.08997772e+00 -2.61186521 0.93144570 492.25 -1.79986134e+00 -8.81626473e-01 2.00418714e+00 -2.68611392 0.93251349 492.50 -1.84180910e+00 -6.23298546e-01 1.94441812e+00 -2.81527427 0.90671118 492.75 -1.82359955e+00 -4.59715586e-01 1.88065248e+00 -2.89464565 0.93795626 493.00 -1.97380205e+00 -2.65296458e-01 1.99155134e+00 -3.00798454 0.93616464 493.25 -2.01322301e+00 -1.40010906e-01 2.01808571e+00 -3.07215880 0.93527039 493.50 -2.02953108e+00 2.41948252e-02 2.02967529e+00 3.12967183 0.93456496 493.75 -2.01897305e+00 2.00539997e-01 2.02890819e+00 3.04258967 0.93772602 494.00 -1.96948386e+00 3.69600125e-01 2.00386400e+00 2.95608681 0.92836260 494.25 -1.89005384e+00 5.31119614e-01 1.96326044e+00 2.86764979 0.93372507 494.50 -1.83079090e+00 6.48715091e-01 1.94232505e+00 2.80106028 0.92828919 494.75 -1.74777247e+00 8.19388687e-01 1.93031252e+00 2.70319964 0.91186270 495.00 -1.78541150e+00 1.11598602e+00 2.10549734e+00 2.58295152 0.93217867 495.25 -1.69205584e+00 1.22185524e+00 2.08709923e+00 2.51617951 0.92884884 495.50 -1.41034789e+00 1.39570199e+00 1.98420392e+00 2.36141384 0.91689593 495.75 -1.32406154e+00 1.52250048e+00 2.01770827e+00 2.28659529 0.91244203 496.00 -1.06387020e+00 1.61288675e+00 1.93215514e+00 2.15389502 0.90668040 496.25 -8.87935485e-01 1.61257302e+00 1.84087511e+00 2.07412519 0.90965743 496.50 -5.88628637e-01 1.74451312e+00 1.84114359e+00 1.89621780 0.89345821 496.75 -3.97215152e-01 1.54106949e+00 1.59143805e+00 1.82305843 0.84477775 497.00 -2.45287388e-01 1.35175111e+00 1.37382567e+00 1.75030210 0.81436393 497.25 -2.40185534e-01 1.36974302e+00 1.39064195e+00 1.74438235 0.78029776 497.50 -3.42847704e-01 1.38065364e+00 1.42258533e+00 1.81419578 0.77628122 497.75 -1.68494786e-01 1.40411172e+00 1.41418535e+00 1.69022622 0.77904823 498.00 1.77227983e-02 1.29424776e+00 1.29436910e+00 1.55710367 0.77237208 498.25 1.70069086e-01 1.24143488e+00 1.25302995e+00 1.43464984 0.75211236 498.50 2.27550597e-01 1.27194976e+00 1.29214375e+00 1.39377000 0.79038062 498.75 3.39201189e-01 1.35499921e+00 1.39681076e+00 1.32550416 0.75588609 499.00 4.47017958e-01 1.31866251e+00 1.39237060e+00 1.24396034 0.80260808 499.25 8.21513109e-01 1.40324137e+00 1.62602894e+00 1.04115178 0.78490841 499.50 1.06633988e+00 1.29524611e+00 1.67771965e+00 0.88202533 0.79113803 499.75 1.07961816e+00 1.11995371e+00 1.55559368e+00 0.80373402 0.74443296 500.00 1.36902666e+00 9.15029869e-01 1.64666744e+00 0.58918773 0.74508517 500.25 1.62037851e+00 4.04466358e-01 1.67009567e+00 0.24461371 0.75569903 500.50 1.68154250e+00 3.28558245e-02 1.68186346e+00 0.01953661 0.79648303 500.75 1.76514274e+00 -2.18749403e-01 1.77864561e+00 -0.12329867 0.79946369 501.00 1.74651536e+00 -3.65977153e-01 1.78444815e+00 -0.20655834 0.77587999 501.25 1.43080172e+00 -9.00493979e-01 1.69058657e+00 -0.56173076 0.68301296 501.50 1.39554506e+00 -1.10726342e+00 1.78145398e+00 -0.67072027 0.73513026 501.75 9.31169981e-01 -1.24017809e+00 1.55084468e+00 -0.92676059 0.61508528 502.00 5.98997705e-01 -1.41242577e+00 1.53419190e+00 -1.16969547 0.70646992 502.25 3.93402883e-01 -1.37565328e+00 1.43079970e+00 -1.29225535 0.73622368 502.50 4.40812867e-01 -1.34115260e+00 1.41173875e+00 -1.25323770 0.77960834 502.75 3.47958376e-01 -1.19901869e+00 1.24848742e+00 -1.28835200 0.68427872 503.00 3.39910088e-01 -1.14759640e+00 1.19687775e+00 -1.28283579 0.67673705 503.25 3.29298420e-01 -1.09000841e+00 1.13866404e+00 -1.27740826 0.51348330 503.50 2.82066960e-01 -1.03692495e+00 1.07460464e+00 -1.30520034 0.47044964 503.75 5.65879418e-01 -7.57240970e-01 9.45321851e-01 -0.92903119 0.38170678 504.00 9.32828861e-01 -1.06129956e+00 1.41298494e+00 -0.84973374 0.57372376 504.25 1.16331303e+00 -1.28920142e+00 1.73647272e+00 -0.83668349 0.73894515 504.50 1.34582695e+00 -1.31382481e+00 1.88079393e+00 -0.77336629 0.81201167 504.75 1.38871906e+00 -1.11649782e+00 1.78188328e+00 -0.67716108 0.66999267 505.00 1.53282096e+00 -1.39367998e+00 2.07168626e+00 -0.73788877 0.67680353 505.25 1.66001931e+00 -1.81028081e+00 2.45617196e+00 -0.82867042 0.79917248 505.50 1.83012269e+00 -2.00051876e+00 2.71135102e+00 -0.82985125 0.75749245 505.75 2.72127177e+00 -1.89150833e+00 3.31407963e+00 -0.60741798 0.76977041 506.00 3.05278841e+00 -1.59413627e+00 3.44394941e+00 -0.48124179 0.73299315 506.25 3.81825046e+00 -2.28816722e+00 4.45137572e+00 -0.53988338 0.75215444 506.50 4.18623517e+00 -2.52505844e+00 4.88881222e+00 -0.54275535 0.71190858 506.75 5.32893256e+00 -3.34960314e+00 6.29423255e+00 -0.56116185 0.65431694 507.00 6.71660880e+00 -3.57421444e+00 7.60840605e+00 -0.48903224 0.69815753 507.25 7.96509706e+00 -3.85921666e+00 8.85078100e+00 -0.45118382 0.76592449 507.50 8.60794904e+00 -2.69022756e+00 9.01854262e+00 -0.30291064 0.70220793 507.75 8.74712984e+00 -9.10783921e-01 8.79441913e+00 -0.10374988 0.66588145 508.00 8.80521857e+00 5.04376047e-01 8.81965245e+00 0.05721896 0.67146040 508.25 9.14788969e+00 2.84597878e+00 9.58036956e+00 0.30161592 0.76717419 508.50 8.28148978e+00 2.93544509e+00 8.78634798e+00 0.34064129 0.69278394 508.75 6.32519606e+00 4.45434809e+00 7.73623436e+00 0.61355452 0.70282011 509.00 4.47389572e+00 5.77997025e+00 7.30915857e+00 0.91208981 0.74174454 509.25 2.62285689e+00 6.50715132e+00 7.01586748e+00 1.18764364 0.82348250 509.50 1.07458846e+00 6.99070124e+00 7.07281021e+00 1.41827333 0.81719604 509.75 -7.88067703e-01 7.38992704e+00 7.43182833e+00 1.67703561 0.81337436 510.00 -2.29704050e+00 6.41928157e+00 6.81788611e+00 1.91443355 0.66851463 510.25 -4.47904356e+00 5.70194715e+00 7.25079530e+00 2.23665085 0.62545204 510.50 -5.80508492e+00 5.22013431e+00 7.80697208e+00 2.40920048 0.65387431 510.75 -7.01262616e+00 5.25685148e+00 8.76421207e+00 2.49833053 0.62226007 511.00 -7.98720993e+00 2.94616984e+00 8.51325080e+00 2.78821500 0.39717928 511.25 -6.60632805e+00 2.60107923e+00 7.09994250e+00 2.76650708 0.18895052 511.50 -3.78140801e+00 3.25522426e+00 4.98954221e+00 2.43083336 0.08243625 511.75 -3.04171543e+00 4.10578475e+00 5.10974571e+00 2.20840699 0.06166556 512.00 -7.19534714e+00 1.25929377e-01 7.19644903e+00 3.12409294 0.14700831 512.25 -5.54018520e+00 -6.50430207e-01 5.57823552e+00 -3.02472538 0.11063977 512.50 -4.27521363e+00 -9.39468399e-01 4.37721971e+00 -2.92528301 0.08265178 512.75 -6.97518850e+00 -6.56467939e-01 7.00601204e+00 -3.04775434 0.18326593 513.00 -5.97849383e+00 6.97249058e-01 6.01901526e+00 3.02549094 0.16239903 513.25 -7.39277649e+00 3.34946708e-01 7.40036036e+00 3.09631632 0.22260521 513.50 -6.73454862e+00 -6.01880625e-01 6.76139079e+00 -3.05245739 0.19215895 513.75 -5.65426299e+00 -3.14559197e-01 5.66300604e+00 -3.08601772 0.20855892 514.00 -5.49032501e+00 -4.75188128e+00 7.26113245e+00 -2.42816806 0.45242676 514.25 -4.59218073e+00 -5.53479239e+00 7.19180441e+00 -2.26338260 0.61911420 514.50 -2.94763267e+00 -5.05482192e+00 5.85147528e+00 -2.09872117 0.67559775 514.75 -2.37238675e+00 -4.60233219e+00 5.17780653e+00 -2.04674708 0.67569938 515.00 -1.06306047e+00 -4.51065482e+00 4.63423181e+00 -1.80225036 0.69695369 515.25 -5.63485533e-01 -4.59128054e+00 4.62572945e+00 -1.69291512 0.76937871 515.50 1.23477575e-01 -4.68447913e+00 4.68610621e+00 -1.54444356 0.76651154 515.75 6.07802298e-01 -4.60563087e+00 4.64556341e+00 -1.43958515 0.76857839 516.00 1.36454276e+00 -5.02203016e+00 5.20411028e+00 -1.30549008 0.76936726 516.25 1.16179100e+00 -5.36608760e+00 5.49041478e+00 -1.35758100 0.80434642 516.50 1.01824389e+00 -5.19828195e+00 5.29707049e+00 -1.37736461 0.88592067 516.75 9.25008965e-01 -5.01967916e+00 5.10419635e+00 -1.38856420 0.87387713 517.00 3.29704225e-01 -4.45223591e+00 4.46442712e+00 -1.49687762 0.73265657 517.25 1.48742483e-01 -3.90012920e+00 3.90296453e+00 -1.53267697 0.74067347 517.50 3.81028524e-01 -2.94798861e+00 2.97251066e+00 -1.44225860 0.74686712 517.75 5.90180241e-01 -2.50041221e+00 2.56911929e+00 -1.33900548 0.64434754 518.00 1.27940113e+00 -2.10121737e+00 2.46007758e+00 -1.02386885 0.58117275 518.25 2.14613451e+00 -1.80677463e+00 2.80541047e+00 -0.69975749 0.56714330 518.50 3.42966450e+00 -2.30774548e+00 4.13379823e+00 -0.59229038 0.75347505 518.75 3.75711965e+00 -3.00432992e+00 4.81060769e+00 -0.67451924 0.71695721 519.00 2.98658879e+00 -4.51511923e+00 5.41350296e+00 -0.98640423 0.74554674 519.25 1.74633472e+00 -4.79386949e+00 5.10204563e+00 -1.22145256 0.75873182 519.50 5.35097683e-01 -4.87541337e+00 4.90469011e+00 -1.46147955 0.85295212 519.75 6.52744447e-02 -4.48903229e+00 4.48950684e+00 -1.55625648 0.77688277 520.00 -7.32192177e-01 -3.98187793e+00 4.04863646e+00 -1.75264602 0.66631624 520.25 -2.35777088e+00 -3.55747466e+00 4.26786943e+00 -2.15609314 0.62215172 520.50 -3.22127656e+00 -2.53997257e+00 4.10220469e+00 -2.47390411 0.66170645 520.75 -3.63111675e+00 -3.61196210e-01 3.64903707e+00 -3.04244632 0.50303921 521.00 -4.23508429e+00 1.96319590e+00 4.66798426e+00 2.70752347 0.60252165 521.25 -2.88118898e+00 5.16824557e+00 5.91709492e+00 2.07936352 0.63483471 521.50 4.49463027e-01 8.02726897e+00 8.03984230e+00 1.51486271 0.76244820 521.75 5.01444595e+00 7.95371836e+00 9.40246265e+00 1.00828533 0.76795618 522.00 9.41812422e+00 6.49656336e+00 1.14414334e+01 0.60384325 0.81002278 522.25 1.08368367e+01 1.26017298e+00 1.09098609e+01 0.11576611 0.83768951 522.50 1.07333129e+01 -1.92954804e+00 1.09053730e+01 -0.17787199 0.89783834 522.75 9.60602488e+00 -4.03017491e+00 1.04171985e+01 -0.39724250 0.88264266 523.00 9.02808898e+00 -5.61498253e+00 1.06317646e+01 -0.55640006 0.90581173 523.25 7.09602284e+00 -8.25568358e+00 1.08862230e+01 -0.86079450 0.88402061 523.50 5.18515363e+00 -9.39433525e+00 1.07303007e+01 -1.06646128 0.92872504 523.75 2.01476410e+00 -1.05629887e+01 1.07534183e+01 -1.38232212 0.89912365 524.00 -7.99269193e-01 -1.00969641e+01 1.01285496e+01 -1.64979096 0.89403478 524.25 -3.50827704e+00 -8.87140272e+00 9.53990534e+00 -1.94738203 0.87749143 524.50 -4.94784268e+00 -7.60287539e+00 9.07110034e+00 -2.14772370 0.86789496 524.75 -7.27740998e+00 -3.86577895e+00 8.24044555e+00 -2.65329569 0.81412725 525.00 -7.89010094e+00 -2.12678403e+00 8.17171360e+00 -2.87829943 0.82652520 525.25 -7.05001280e+00 1.89688985e+00 7.30074459e+00 2.87875538 0.80582940 525.50 -6.61004999e+00 3.33036128e+00 7.40162598e+00 2.67488335 0.83902362 525.75 -3.94892755e+00 6.35882818e+00 7.48523377e+00 2.12652488 0.76414611 526.00 -1.76197576e+00 7.01337276e+00 7.23131773e+00 1.81693312 0.75005531 526.25 3.18415680e+00 7.65900558e+00 8.29452958e+00 1.17679485 0.79005077 526.50 4.68658277e+00 6.98042754e+00 8.40775990e+00 0.97953149 0.82483886 526.75 6.49350174e+00 4.55627341e+00 7.93254009e+00 0.61184362 0.83305558 527.00 7.13799613e+00 3.22583866e+00 7.83307244e+00 0.42445358 0.84005636 527.25 6.91197715e+00 1.02089141e+00 6.98696267e+00 0.14663872 0.88198609 527.50 6.26389522e+00 3.61402065e-01 6.27431229e+00 0.05763217 0.88847622 527.75 5.52131075e+00 -5.12554360e-01 5.54505044e+00 -0.09256671 0.93165950 528.00 5.14583023e+00 -7.49060513e-01 5.20006350e+00 -0.14455121 0.92862784 528.25 4.73425332e+00 -1.14004066e+00 4.86958388e+00 -0.23630775 0.93912730 528.50 4.38553688e+00 -1.12091696e+00 4.52652058e+00 -0.25023665 0.92617504 528.75 3.84571122e+00 -1.11877907e+00 4.00514187e+00 -0.28310219 0.92822147 529.00 3.74332506e+00 -8.78957504e-01 3.84513313e+00 -0.23062869 0.91686137 529.25 3.71336832e+00 -2.93903777e-01 3.72498103e+00 -0.07898284 0.95408343 529.50 4.21053551e+00 -2.68554093e-01 4.21909120e+00 -0.06369518 0.94633619 529.75 4.61589616e+00 -1.12821859e+00 4.75177594e+00 -0.23972030 0.94754898 530.00 4.28079129e+00 -1.47651865e+00 4.52827576e+00 -0.33213958 0.91783454 530.25 3.98613272e+00 -1.68679034e+00 4.32833868e+00 -0.40031504 0.92599189 530.50 3.97622702e+00 -1.67568850e+00 4.31489435e+00 -0.39884020 0.95140652 530.75 3.96903129e+00 -1.73492218e+00 4.33164684e+00 -0.41208705 0.96740969 531.00 3.96014500e+00 -1.62470922e+00 4.28047059e+00 -0.38932415 0.93973366 531.25 3.86154725e+00 -1.52603725e+00 4.15214846e+00 -0.37635126 0.90438002 531.50 4.10543798e+00 -1.66649821e+00 4.43078292e+00 -0.38560332 0.90033340 531.75 4.43270750e+00 -2.18750282e+00 4.94308247e+00 -0.45842715 0.92683735 532.00 4.34393843e+00 -2.82712577e+00 5.18289892e+00 -0.57695206 0.93678544 532.25 4.00514279e+00 -3.16122494e+00 5.10240256e+00 -0.66817714 0.92934890 532.50 3.52960273e+00 -3.13684229e+00 4.72206258e+00 -0.72655016 0.90997607 532.75 3.42806168e+00 -2.75490032e+00 4.39784978e+00 -0.67695170 0.90073298 533.00 3.22040681e+00 -2.24486694e+00 3.92561429e+00 -0.60876057 0.87686020 533.25 3.09168360e+00 -1.86643979e+00 3.61138546e+00 -0.54313337 0.86034197 533.50 3.67648692e+00 -1.60431746e+00 4.01128291e+00 -0.41146361 0.78506890 533.75 4.44010513e+00 -1.63454731e+00 4.73141400e+00 -0.35273636 0.81672091 534.00 4.99917308e+00 -2.26718181e+00 5.48924811e+00 -0.42577014 0.88999255 534.25 5.20901850e+00 -2.86789174e+00 5.94631624e+00 -0.50327519 0.92575941 534.50 4.84023794e+00 -4.21223663e+00 6.41645079e+00 -0.71613569 0.91556619 534.75 4.36727835e+00 -4.88320384e+00 6.55124415e+00 -0.84111326 0.91355334 535.00 3.72000611e+00 -5.50614113e+00 6.64500079e+00 -0.97662745 0.90990810 535.25 3.51427205e+00 -5.54206140e+00 6.56235877e+00 -1.00567339 0.92032789 535.50 3.06094492e+00 -5.79818494e+00 6.55654881e+00 -1.08506744 0.88836880 535.75 2.47030167e+00 -5.97992394e+00 6.47007578e+00 -1.17904881 0.87049753 536.00 1.26612672e+00 -6.01170353e+00 6.14358659e+00 -1.36321968 0.83123532 536.25 2.64269706e-01 -5.88500627e+00 5.89093687e+00 -1.52592088 0.82100240 536.50 -1.26924330e+00 -4.82857339e+00 4.99260449e+00 -1.82784229 0.82491738 536.75 -1.25176513e+00 -4.18567213e+00 4.36884048e+00 -1.86139008 0.76390099 537.00 -1.53846766e+00 -2.45785431e+00 2.89964318e+00 -2.13007083 0.54088744 537.25 -1.88789986e+00 -1.48756687e+00 2.40354345e+00 -2.47424383 0.38206956 537.50 -6.29606893e-01 1.27803177e+00 1.42469999e+00 2.02853693 0.07801857 537.75 9.41680385e-01 2.58755571e+00 2.75358067e+00 1.22176900 0.18720483 538.00 4.67996334e+00 3.58785917e+00 5.89701537e+00 0.65406755 0.21534870 538.25 7.19468008e+00 -2.32970162e-01 7.19845098e+00 -0.03236958 0.17428001 538.50 5.26492798e+00 -1.18696635e+01 1.29849289e+01 -1.15330939 0.26906129 538.75 -1.33027974e+00 -1.13147274e+01 1.13926599e+01 -1.68782969 0.32978409 539.00 -6.19907000e+00 -8.00515660e+00 1.01247717e+01 -2.22972181 0.40987068 539.25 -4.19812142e+00 -6.83644492e+00 8.02254340e+00 -2.12150421 0.40963744 539.50 -4.38883278e+00 -6.02493042e+00 7.45396806e+00 -2.20035917 0.50889962 539.75 -4.64883345e+00 -4.61471814e+00 6.55036457e+00 -2.35987722 0.38794314 540.00 -5.28239472e+00 -4.11162065e+00 6.69396134e+00 -2.48018494 0.35000595 540.25 -6.54218394e+00 -2.94974871e+00 7.17643283e+00 -2.71800604 0.29834047 540.50 -6.55270316e+00 -1.86182197e+00 6.81207016e+00 -2.86475798 0.34604214 540.75 -5.51269803e+00 -9.97649277e-01 5.60224452e+00 -2.96255745 0.36601149 541.00 -4.72928668e+00 -4.38198651e-01 4.74954425e+00 -3.04920006 0.49017964 541.25 -3.92875041e+00 -2.70065844e-01 3.93802176e+00 -3.07295972 0.35963362 541.50 -2.70596236e+00 -3.74702973e-01 2.73178231e+00 -3.00399458 0.27232738 541.75 -1.44249251e+00 -4.52488117e-01 1.51179699e+00 -2.83762867 0.10956526 542.00 -1.05686715e+00 -1.81149501e-01 1.07227949e+00 -2.97183986 0.07911045 542.25 -1.00182912e+00 -6.17669231e-01 1.17693537e+00 -2.58909899 0.12898469 542.50 -1.00655339e+00 -8.25452347e-01 1.30173780e+00 -2.45472833 0.17188139 542.75 -6.92895868e-01 -1.06139625e+00 1.26754356e+00 -2.14914823 0.08163069 543.00 1.51537813e-01 -1.92804406e+00 1.93399008e+00 -1.49236092 0.16144823 543.25 -4.48262879e-01 -2.67955846e+00 2.71679465e+00 -1.73655126 0.33708396 543.50 -6.95353775e-01 -3.38057399e+00 3.45134718e+00 -1.77365800 0.50843883 543.75 -2.38399905e+00 -3.09834744e+00 3.90937442e+00 -2.22662473 0.72096656 544.00 -2.84325049e+00 -2.91104636e+00 4.06918471e+00 -2.34441325 0.85007932 544.25 -3.32373281e+00 -2.89274263e+00 4.40626369e+00 -2.42541404 0.81306569 544.50 -3.80285675e+00 -2.24277693e+00 4.41494822e+00 -2.60873578 0.82203316 544.75 -3.45227381e+00 -1.35637354e+00 3.70917021e+00 -2.76722814 0.80752497 545.00 -3.72530334e+00 -7.92460923e-01 3.80865846e+00 -2.93199308 0.82745492 545.25 -3.95044121e+00 -5.24268726e-01 3.98507759e+00 -3.00965221 0.86100299 545.50 -3.96370585e+00 -4.77735346e-01 3.99239216e+00 -3.02164380 0.85399286 545.75 -4.02313122e+00 3.89012907e-01 4.04189508e+00 3.04519827 0.82182169 546.00 -4.08449840e+00 8.40978957e-01 4.17017659e+00 2.93853503 0.80674190 546.25 -4.23497525e+00 1.08446227e+00 4.37162142e+00 2.89090657 0.79574940 546.50 -4.13161742e+00 1.41317002e+00 4.36661334e+00 2.81202849 0.76005601 546.75 -3.48354588e+00 1.72152936e+00 3.88571168e+00 2.68260480 0.63723034 547.00 -3.25697206e+00 1.62607452e+00 3.64032764e+00 2.67853755 0.58449846 547.25 -2.19052084e+00 2.17793304e+00 3.08897619e+00 2.35907601 0.49736664 547.50 -1.67150432e+00 1.89739112e+00 2.52863990e+00 2.29298561 0.44762766 547.75 -1.18758891e+00 5.14805238e-01 1.29436929e+00 2.73255483 0.11161833 548.00 -2.25960805e+00 -4.87111628e-01 2.31151601e+00 -2.92926839 0.18220331 548.25 -5.42471516e+00 -8.45088768e-01 5.49014659e+00 -2.98704995 0.54073437 548.50 -6.97530914e+00 -6.19448078e-01 7.00276042e+00 -3.05301919 0.52745995 548.75 -1.00894895e+01 5.06734799e+00 1.12905188e+01 2.67615443 0.47297510 549.00 -6.64705644e+00 9.81346159e+00 1.18527376e+01 2.16615225 0.47003382 549.25 -7.27544443e-01 1.34847118e+01 1.35043242e+01 1.62469735 0.53701247 549.50 3.08053319e+00 1.29192521e+01 1.32814442e+01 1.33672202 0.57015770 549.75 8.50104305e+00 1.18572215e+01 1.45897716e+01 0.94878442 0.76927661 550.00 1.07981989e+01 9.04381587e+00 1.40851590e+01 0.69720991 0.70424853 550.25 9.71637525e+00 5.02436573e+00 1.09385648e+01 0.47723612 0.75897507 550.50 9.16067602e+00 4.17583002e+00 1.00675489e+01 0.42770233 0.77980142 550.75 8.88028806e+00 3.13058065e+00 9.41594664e+00 0.33892821 0.79601518 551.00 8.63035765e+00 2.26325014e+00 8.92218439e+00 0.25646780 0.83014849 551.25 8.47577932e+00 1.79799555e+00 8.66438821e+00 0.20903457 0.87159615 551.50 8.37353856e+00 1.22782695e+00 8.46307905e+00 0.14559424 0.86375077 551.75 7.99268971e+00 1.16023529e+00 8.07646177e+00 0.14415514 0.82554874 552.00 8.20697165e+00 7.59707424e-01 8.24205915e+00 0.09230549 0.80312664 552.25 8.66873141e+00 5.74510190e-01 8.68774805e+00 0.06617707 0.87503145 552.50 8.86913932e+00 7.69884287e-02 8.86947346e+00 0.00868027 0.88930487 552.75 9.35231923e+00 -1.15930627e+00 9.42389867e+00 -0.12333010 0.91349593 553.00 9.28999875e+00 -2.24129272e+00 9.55654069e+00 -0.23673476 0.89897214 553.25 9.29525912e+00 -2.93978762e+00 9.74906115e+00 -0.30631342 0.89485343 553.50 8.16716978e+00 -4.21406602e+00 9.19026739e+00 -0.47634681 0.86674212 553.75 7.66669885e+00 -4.93830412e+00 9.11949115e+00 -0.57223331 0.86613541 554.00 7.68800543e+00 -5.61496203e+00 9.52014843e+00 -0.63080836 0.86961137 554.25 7.13928041e+00 -5.79995536e+00 9.19830457e+00 -0.68225665 0.89577828 554.50 6.81933570e+00 -6.00165262e+00 9.08422664e+00 -0.72170751 0.85110843 554.75 6.45567919e+00 -6.35464784e+00 9.05855082e+00 -0.77751162 0.85240642 555.00 5.80089319e+00 -6.44053199e+00 8.66780330e+00 -0.83760267 0.84144980 555.25 5.44879997e+00 -6.00940898e+00 8.11186893e+00 -0.83428559 0.85186764 555.50 5.16710598e+00 -6.16038386e+00 8.04047968e+00 -0.87286183 0.86800421 555.75 4.40196570e+00 -6.45419935e+00 7.81242544e+00 -0.97223199 0.87856805 556.00 5.19590956e+00 -6.17769630e+00 8.07226163e+00 -0.87150621 0.87350595 556.25 5.75019030e+00 -6.15957651e+00 8.42645069e+00 -0.81975862 0.88465742 556.50 6.16319644e+00 -7.77654992e+00 9.92268708e+00 -0.90062315 0.84030617 556.75 5.78688784e+00 -9.38309357e+00 1.10240880e+01 -1.01816204 0.86169340 557.00 3.84852997e+00 -1.14622816e+01 1.20911159e+01 -1.24686695 0.85529797 557.25 2.21266840e+00 -1.20633397e+01 1.22645858e+01 -1.38939185 0.86006343 557.50 -1.36980421e+00 -1.18009887e+01 1.18802230e+01 -1.68635456 0.81938567 557.75 -1.84474520e+00 -1.13749259e+01 1.15235422e+01 -1.73157300 0.82564595 558.00 -2.25338409e+00 -9.07128581e+00 9.34697630e+00 -1.81427650 0.86314160 558.25 -2.49757332e+00 -8.08939476e+00 8.46617860e+00 -1.87025810 0.82114854 558.50 -1.87547411e+00 -6.72514951e+00 6.98176475e+00 -1.84276124 0.82481515 558.75 -1.32174779e+00 -6.14403400e+00 6.28459792e+00 -1.78269390 0.79545681 559.00 -1.26924844e+00 -6.15797472e+00 6.28741953e+00 -1.77406433 0.74799577 559.25 -9.11947246e-01 -6.22889080e+00 6.29529414e+00 -1.71616956 0.68089360 559.50 -1.24290464e+00 -6.03345246e+00 6.16014290e+00 -1.77395654 0.54571224 559.75 -1.13842185e+00 -5.94627088e+00 6.05426640e+00 -1.75995872 0.47677710 560.00 -5.87491433e-01 -8.41826461e+00 8.43873955e+00 -1.64047107 0.67474303 560.25 -3.46312303e-01 -8.71155026e+00 8.71843106e+00 -1.61052864 0.62237290 560.50 7.97853150e-01 -1.05662743e+01 1.05963542e+01 -1.49542994 0.60275910 560.75 -3.47019987e-01 -1.22577570e+01 1.22626681e+01 -1.59909900 0.59415183 561.00 -3.43999658e+00 -1.25059489e+01 1.29704407e+01 -1.83922652 0.54138758 561.25 -4.64189098e+00 -1.31923859e+01 1.39852136e+01 -1.90912842 0.53630351 561.50 -8.77707911e+00 -1.50533786e+01 1.74253070e+01 -2.09866960 0.47872948 561.75 -1.36406206e+01 -8.41572311e+00 1.60278173e+01 -2.58879551 0.42136693 562.00 -1.60436903e+01 -3.43309204e+00 1.64068924e+01 -2.93078786 0.53032406 562.25 -1.56457770e+01 2.32683888e+00 1.58178544e+01 2.99395484 0.57921442 562.50 -1.68423327e+01 4.67663520e+00 1.74795620e+01 2.87074450 0.59760534 562.75 -1.20004815e+01 6.98509404e+00 1.38853554e+01 2.61446295 0.59345091 563.00 -9.80436849e+00 7.44728527e+00 1.23120957e+01 2.49198311 0.60616550 563.25 -5.54425516e+00 6.92035847e+00 8.86736300e+00 2.24623897 0.57168149 563.50 -3.80978245e+00 6.52838470e+00 7.55872008e+00 2.09904882 0.55770699 563.75 -2.24062898e+00 5.17421633e+00 5.63852222e+00 1.97945495 0.45262228 564.00 -1.37206383e+00 5.14352089e+00 5.32337921e+00 1.83148190 0.53169132 564.25 -3.49316959e-01 2.32714266e+00 2.35321382e+00 1.71978947 0.19243708 564.50 -8.47402676e-01 1.38015072e+00 1.61953923e+00 2.12144121 0.13292460 564.75 -8.89608772e-01 -3.04594585e-02 8.90130072e-01 -3.10736686 0.04237212 565.00 -9.09048112e-01 -1.33712432e+00 1.61687041e+00 -2.16787253 0.11076002 565.25 -2.98188937e+00 -1.76890292e+00 3.46708548e+00 -2.60617671 0.30873879 565.50 -3.67442063e+00 -1.45076192e+00 3.95045277e+00 -2.76555336 0.34182824 565.75 -4.30523928e+00 1.73354211e+00 4.64114787e+00 2.75879639 0.30542570 566.00 -3.89242597e+00 2.06113604e+00 4.40445930e+00 2.65460514 0.28295474 566.25 -6.43677998e-01 3.94673185e-01 7.55041912e-01 2.59155782 0.01147807 566.50 1.06906876e+00 -4.87993741e-01 1.17517909e+00 -0.42821818 0.02973387 566.75 1.56706978e+00 -4.33916578e+00 4.61346588e+00 -1.22422713 0.31568240 567.00 4.61327482e-02 -6.12245915e+00 6.12263295e+00 -1.56326147 0.48295265 567.25 -2.75965680e+00 -8.39173869e+00 8.83385442e+00 -1.88851007 0.67291950 567.50 -5.30302552e+00 -8.89862681e+00 1.03589400e+01 -2.10822335 0.75919365 567.75 -9.13307359e+00 -8.14599856e+00 1.22380687e+01 -2.41325794 0.83516115 568.00 -1.11978877e+01 -6.92846180e+00 1.31680018e+01 -2.58751528 0.86869769 568.25 -1.28879632e+01 -5.10913788e+00 1.38637255e+01 -2.76417015 0.88862461 568.50 -1.42228594e+01 -3.15219317e+00 1.45679803e+01 -2.92348941 0.90789210 568.75 -1.48260976e+01 -8.70234023e-01 1.48516153e+01 -3.08296383 0.89856808 569.00 -1.52265228e+01 -6.72316843e-01 1.52413584e+01 -3.09746699 0.91143590 569.25 -1.50588942e+01 1.09172808e+00 1.50984160e+01 3.06922204 0.92551283 569.50 -1.47063109e+01 2.28957336e+00 1.48834715e+01 2.98714608 0.92647629 569.75 -1.52946127e+01 3.66102738e+00 1.57266748e+01 2.90664617 0.93564859 570.00 -1.52034460e+01 4.43347246e+00 1.58366805e+01 2.85785104 0.93804980 570.25 -1.53762856e+01 6.99272936e+00 1.68916673e+01 2.71477606 0.90257175 570.50 -1.61422762e+01 9.55010939e+00 1.87557370e+01 2.60735697 0.88754073 570.75 -1.50949942e+01 1.25840044e+01 1.96523795e+01 2.44666508 0.85222816 571.00 -1.17198133e+01 1.36403596e+01 1.79836991e+01 2.28060797 0.85742639 571.25 -1.03884372e+01 1.42006063e+01 1.75947960e+01 2.20238375 0.92177051 571.50 -1.09380328e+01 1.50517888e+01 1.86063674e+01 2.19921347 0.93355963 571.75 -1.03039996e+01 1.60243822e+01 1.90513315e+01 2.14224909 0.93066878 572.00 -8.05158970e+00 1.73013631e+01 1.90831146e+01 2.00636076 0.90826167 572.25 -5.77773833e+00 1.89460464e+01 1.98074465e+01 1.86679503 0.91083113 572.50 -4.44269235e+00 2.10626922e+01 2.15261357e+01 1.77867629 0.90525787 572.75 -1.13538986e+00 2.12388384e+01 2.12691647e+01 1.62420368 0.87856769 573.00 1.67075259e+00 1.93623414e+01 1.94342913e+01 1.48472077 0.87362036 573.25 3.26025796e+00 1.70557152e+01 1.73645243e+01 1.38192140 0.80099633 573.50 1.49964494e+00 1.46372864e+01 1.47139080e+01 1.46869881 0.79996658 573.75 3.87790417e-01 1.44656907e+01 1.44708876e+01 1.54399515 0.86855762 574.00 -3.24023012e-01 1.58415010e+01 1.58448144e+01 1.59124754 0.83988791 574.25 -9.45975542e-02 1.70299293e+01 1.70301920e+01 1.57635105 0.83925505 574.50 1.76553425e+00 2.11966609e+01 2.12700622e+01 1.48769511 0.83861973 574.75 5.13659455e+00 2.50458681e+01 2.55671687e+01 1.36851376 0.86412703 575.00 1.15633783e+01 2.65034062e+01 2.89161245e+01 1.15939538 0.84077071 575.25 1.67020703e+01 2.48444711e+01 2.99367148e+01 0.97892791 0.85974614 575.50 2.37510788e+01 2.39418646e+01 3.37242735e+01 0.78939844 0.84268647 575.75 2.86630111e+01 2.07008025e+01 3.53566321e+01 0.62547905 0.85257208 576.00 3.08412736e+01 1.52326502e+01 3.43979329e+01 0.45875950 0.79245239 576.25 3.52484118e+01 1.18506440e+01 3.71872061e+01 0.32433159 0.76795429 576.50 3.48309055e+01 1.51104762e+00 3.48636665e+01 0.04335520 0.67088446 576.75 3.51082168e+01 -1.09199835e+01 3.67672807e+01 -0.30155223 0.69370671 577.00 2.98178085e+01 -1.69847860e+01 3.43159534e+01 -0.51778080 0.67376368 577.25 2.12244496e+01 -2.32232800e+01 3.14610552e+01 -0.83033824 0.70704555 577.50 1.17862850e+01 -2.61481939e+01 2.86817810e+01 -1.14731930 0.77052732 577.75 1.02872893e+01 -2.30984327e+01 2.52856860e+01 -1.15180153 0.73948428 578.00 5.66868040e+00 -1.83664617e+01 1.92213645e+01 -1.27142913 0.69994909 578.25 4.20824352e+00 -1.48282854e+01 1.54138691e+01 -1.29426886 0.60860800 578.50 2.52345834e+00 -1.48605962e+01 1.50733262e+01 -1.40259211 0.70180467 578.75 2.65253630e+00 -1.50051976e+01 1.52378445e+01 -1.39582941 0.76801221 579.00 1.39434804e+00 -1.17347352e+01 1.18172847e+01 -1.45252856 0.66505390 579.25 3.98091342e-01 -1.20234317e+01 1.20300203e+01 -1.53769879 0.73148009 579.50 1.46939165e+00 -1.34262255e+01 1.35063927e+01 -1.46178826 0.73936000 579.75 8.60645674e-01 -1.20840755e+01 1.21146850e+01 -1.49969491 0.68524135 580.00 -1.63273914e+00 -1.17073151e+01 1.18206203e+01 -1.70936571 0.72957435 580.25 -3.01955724e+00 -1.13033081e+01 1.16996795e+01 -1.83183987 0.76643300 580.50 -4.92979580e+00 -9.80525337e+00 1.09747838e+01 -2.03665818 0.84137983 580.75 -6.03007939e+00 -7.78541324e+00 9.84756400e+00 -2.22981617 0.82952182 581.00 -6.54998658e+00 -5.16401288e+00 8.34082449e+00 -2.47396469 0.85659767 581.25 -6.13619626e+00 -3.98897592e+00 7.31879999e+00 -2.56516607 0.84128794 581.50 -5.06534410e+00 -2.38050159e+00 5.59682934e+00 -2.70226575 0.73445008 581.75 -3.42764401e+00 -1.44947931e+00 3.72152304e+00 -2.74151973 0.50942913 582.00 -3.25479258e+00 -3.49266278e-01 3.27347853e+00 -3.03469341 0.42580131 582.25 -1.28478836e+00 -1.01489592e-01 1.28879062e+00 -3.06276311 0.11344325 582.50 5.81147951e-01 -8.00919372e-02 5.86640997e-01 -0.13695405 0.02494988 582.75 1.79775051e-01 -4.71705437e-01 5.04802029e-01 -1.20667345 0.01740162 583.00 1.14381331e+00 -1.61131783e+00 1.97601975e+00 -0.95348219 0.20240088 583.25 1.76093667e+00 -1.67740262e+00 2.43199044e+00 -0.76110806 0.34472549 583.50 7.29811004e-01 -2.76094096e+00 2.85576944e+00 -1.31237285 0.33809247 583.75 2.41797689e-01 -2.42607845e+00 2.43809818e+00 -1.47145832 0.23558706 584.00 5.20306807e-01 -1.81565955e+00 1.88874000e+00 -1.29170915 0.14148421 584.25 1.11919120e+00 -2.16346818e+00 2.43581270e+00 -1.09339408 0.34074227 584.50 1.09196462e+00 -1.73365733e+00 2.04889103e+00 -1.00870848 0.18742835 584.75 1.87075518e+00 -8.02390039e-01 2.03557233e+00 -0.40517979 0.11247097 585.00 1.30688258e+00 -7.51329533e-01 1.50746083e+00 -0.52176070 0.03490401 585.25 6.42091872e+00 -1.25052117e+00 6.54155948e+00 -0.19234951 0.33521759 585.50 9.50914342e+00 -1.00811634e+00 9.56243207e+00 -0.10562095 0.51099288 585.75 1.04081010e+01 -4.50841264e+00 1.13425902e+01 -0.40876509 0.46855906 586.00 8.85944359e+00 -1.20735694e+01 1.49753404e+01 -0.93775172 0.67250868 586.25 6.36842759e+00 -1.55250666e+01 1.67804816e+01 -1.18152539 0.75114805 586.50 3.25805366e+00 -1.73312904e+01 1.76348672e+01 -1.38497816 0.77377284 586.75 -4.10342134e+00 -1.55705445e+01 1.61021714e+01 -1.82847497 0.71157660 587.00 -1.02443465e+01 -1.61257687e+01 1.91046343e+01 -2.13675247 0.73446531 587.25 -1.65273152e+01 -1.24639719e+01 2.07003078e+01 -2.49544480 0.75071600 587.50 -1.86802473e+01 -8.83128296e+00 2.06626039e+01 -2.69997314 0.69929131 587.75 -1.85912181e+01 3.97024238e+00 1.90104238e+01 2.93119833 0.59793124 588.00 -1.32433473e+01 7.71003875e+00 1.53241948e+01 2.61437764 0.47707865 588.25 -1.03467584e+00 1.12037185e+01 1.12513938e+01 1.66288623 0.32863446 588.50 4.32978089e+00 1.25234121e+01 1.32507680e+01 1.23792617 0.35440240 588.75 1.29144289e+01 -2.33375754e-01 1.29165374e+01 -0.01806896 0.22456692 589.00 1.48908070e+01 -2.96561054e+00 1.51832466e+01 -0.19658499 0.33109733 589.25 1.62631749e+01 -4.85693108e+00 1.69729384e+01 -0.29021407 0.27573887 589.50 1.49718379e+01 -9.73133781e+00 1.78565076e+01 -0.57635847 0.27425350 589.75 1.38017505e+01 -1.75922153e+01 2.23601063e+01 -0.90555518 0.48256530 590.00 1.21773655e+01 -2.02982113e+01 2.36707755e+01 -1.03043339 0.50067135 590.25 7.06329659e+00 -2.13005258e+01 2.24410908e+01 -1.25060480 0.40470730 590.50 4.42043121e+00 -2.42165072e+01 2.46166495e+01 -1.39024619 0.38898433 590.75 -4.32515321e+00 -2.93679360e+01 2.96847203e+01 -1.71701986 0.53485217 591.00 -1.06885885e+01 -2.96796335e+01 3.15456268e+01 -1.91646884 0.67122838 591.25 -2.03472013e+01 -2.29376575e+01 3.06617796e+01 -2.29641908 0.65071536 591.50 -2.11400615e+01 -2.30929353e+01 3.13079201e+01 -2.31207344 0.71462406 591.75 -2.44619674e+01 -2.00498782e+01 3.16288707e+01 -2.45499345 0.74730954 592.00 -2.34853226e+01 -1.64151490e+01 2.86534028e+01 -2.53156937 0.72055302 592.25 -1.96126713e+01 -1.58075407e+01 2.51899825e+01 -2.46321229 0.71218434 592.50 -2.05581171e+01 -1.67313638e+01 2.65061259e+01 -2.45845936 0.75747123 592.75 -2.24130676e+01 -1.95597888e+01 2.97477888e+01 -2.42406921 0.79026250 593.00 -2.39975413e+01 -1.96556770e+01 3.10197942e+01 -2.45533107 0.84288696 593.25 -2.89028161e+01 -1.99604058e+01 3.51253552e+01 -2.53720048 0.84564333 593.50 -3.76696102e+01 -1.85257094e+01 4.19785832e+01 -2.68453092 0.82829879 593.75 -4.73407125e+01 -1.44354038e+01 4.94926655e+01 -2.84562294 0.82733996 594.00 -5.27237401e+01 -5.45377313e-01 5.27265608e+01 -3.13124897 0.77592899 594.25 -5.31924130e+01 1.47701380e+01 5.52049796e+01 2.87074236 0.73119594 594.50 -4.55769136e+01 2.66652846e+01 5.28042845e+01 2.61222997 0.76923957 594.75 -4.07814938e+01 3.12590986e+01 5.13834748e+01 2.48761362 0.78615325 595.00 -3.21679934e+01 3.51985227e+01 4.76834961e+01 2.31123911 0.78207100 595.25 -2.63725394e+01 3.72673693e+01 4.56548754e+01 2.18664319 0.79950883 595.50 -2.27272007e+01 4.24635645e+01 4.81630560e+01 2.06221865 0.82641830 595.75 -1.84864878e+01 4.08753308e+01 4.48613742e+01 1.99553236 0.74365853 596.00 -1.11491585e+01 4.03503471e+01 4.18623249e+01 1.84037897 0.70801433 596.25 -7.39769103e+00 4.15036094e+01 4.21577445e+01 1.74718603 0.75898184 596.50 -6.24295278e+00 4.15367280e+01 4.20032645e+01 1.71997925 0.79029531 596.75 -1.71248513e+00 4.34088257e+01 4.34425914e+01 1.61022604 0.75734324 597.00 6.62582570e+00 4.72881181e+01 4.77500543e+01 1.43158654 0.78189363 597.25 1.19281565e+01 5.03651140e+01 5.17583387e+01 1.33824734 0.79825777 597.50 3.12361685e+01 4.01038743e+01 5.08332466e+01 0.90906578 0.76935720 597.75 3.64865272e+01 3.03797480e+01 4.74783714e+01 0.69432258 0.81374506 598.00 3.91024126e+01 1.91133218e+01 4.35237606e+01 0.45464882 0.78958574 598.25 4.02383663e+01 1.26519440e+01 4.21805383e+01 0.30463754 0.83253902 598.50 3.54944538e+01 5.41497280e+00 3.59051275e+01 0.15139099 0.83381036 598.75 3.03003346e+01 7.98686525e-01 3.03108591e+01 0.02635290 0.82873926 599.00 2.48143645e+01 -2.17326399e+00 2.49093509e+01 -0.08735798 0.76380613 599.25 2.21147052e+01 -2.46864310e+00 2.22520647e+01 -0.11116880 0.70570851 599.50 1.77840469e+01 -5.05190882e+00 1.84876745e+01 -0.27677853 0.65653444 599.75 1.59046963e+01 -4.61538580e+00 1.65608319e+01 -0.28243279 0.65679687 600.00 1.70686217e+01 -4.55329868e+00 1.76655137e+01 -0.26069353 0.63718530 600.25 1.78290239e+01 -4.41399599e+00 1.83672931e+01 -0.24269371 0.66328687 600.50 1.83213239e+01 -5.04727797e+00 1.90038397e+01 -0.26881848 0.75782448 600.75 1.82923430e+01 -6.76724955e+00 1.95039862e+01 -0.35433581 0.74647438 601.00 1.72470980e+01 -1.09162877e+01 2.04114606e+01 -0.56428487 0.70564552 601.25 1.45816627e+01 -1.46441012e+01 2.06657830e+01 -0.78753458 0.62741622 601.50 7.31216926e+00 -1.96679014e+01 2.09831877e+01 -1.21485001 0.66234430 601.75 4.99101421e+00 -1.98013770e+01 2.04206942e+01 -1.32388552 0.67631017 602.00 -3.49397348e-01 -2.07543120e+01 2.07572528e+01 -1.58762966 0.74602913 602.25 -4.88935420e+00 -1.72121833e+01 1.78931562e+01 -1.84756919 0.67907831 602.50 -7.92462587e+00 -1.57917785e+01 1.76686152e+01 -2.03589865 0.74450313 602.75 -9.37200017e+00 -1.12961328e+01 1.46777725e+01 -2.26336547 0.72055502 603.00 -9.32957072e+00 -6.46057356e+00 1.13481232e+01 -2.53592917 0.72592690 603.25 -8.28290347e+00 -4.01367269e+00 9.20413267e+00 -2.69036251 0.69030624 603.50 -6.66118803e+00 -1.71456944e+00 6.87831188e+00 -2.88966437 0.65319059 603.75 -4.19057777e+00 -1.09859611e+00 4.33218830e+00 -2.88520372 0.43553238 604.00 -2.22707358e+00 -1.49670195e-01 2.23209720e+00 -3.07448868 0.26048539 604.25 -8.31375983e-01 -4.07032571e-01 9.25668158e-01 -2.68630845 0.05551685 604.50 4.74716511e-01 -6.28523901e-01 7.87653515e-01 -0.92391953 0.04638764 604.75 1.96452770e+00 -8.26950934e-01 2.13148233e+00 -0.39842791 0.22850941 605.00 3.12745588e+00 -1.81495897e+00 3.61594474e+00 -0.52583129 0.44155191 605.25 5.10083862e+00 -4.27445830e+00 6.65503932e+00 -0.69748094 0.65746161 605.50 5.59664100e+00 -6.51276512e+00 8.58711243e+00 -0.86090825 0.73829657 605.75 4.13058544e+00 -9.41461169e+00 1.02808876e+01 -1.15734391 0.76161757 606.00 2.57056865e+00 -1.07962431e+01 1.10980489e+01 -1.33705012 0.85284421 606.25 4.83364282e-01 -1.16736339e+01 1.16836368e+01 -1.52941347 0.89593033 606.50 -3.88138252e-01 -1.18642662e+01 1.18706135e+01 -1.60349956 0.92840410 606.75 -1.77743452e+00 -1.16051321e+01 1.17404584e+01 -1.72277466 0.90919717 607.00 -2.61244600e+00 -1.18930933e+01 1.21766392e+01 -1.78702304 0.92247734 607.25 -3.35813249e+00 -1.16164251e+01 1.20920794e+01 -1.85220939 0.91898843 607.50 -4.38385185e+00 -1.22111475e+01 1.29742160e+01 -1.91546998 0.92961460 607.75 -6.61431462e+00 -1.29207980e+01 1.45153773e+01 -2.04392825 0.95277025 608.00 -7.16047716e+00 -1.29475235e+01 1.47956344e+01 -2.07596926 0.95649003 608.25 -9.50251002e+00 -1.21942895e+01 1.54595728e+01 -2.23276176 0.93400328 608.50 -1.07126706e+01 -1.16912879e+01 1.58570970e+01 -2.31254169 0.94543902 608.75 -1.26608685e+01 -9.60318131e+00 1.58908365e+01 -2.49267809 0.95426462 609.00 -1.29696442e+01 -8.13507071e+00 1.53098350e+01 -2.58138467 0.96252128 609.25 -1.35064802e+01 -6.73463243e+00 1.50923915e+01 -2.67904780 0.96936310 609.50 -1.34698683e+01 -5.78382727e+00 1.46591272e+01 -2.73600949 0.96704122 609.75 -1.25997735e+01 -3.64028061e+00 1.31151033e+01 -2.86033510 0.96678548 610.00 -1.20579609e+01 -2.57203410e+00 1.23292246e+01 -2.93143631 0.96669905 610.25 -1.07903225e+01 -1.76372349e+00 1.09335164e+01 -2.97957124 0.95329045 610.50 -1.03173606e+01 -1.79335155e+00 1.04720600e+01 -2.96949329 0.94753638 610.75 -8.96370537e+00 -2.12850067e+00 9.21295442e+00 -2.90845291 0.93485060 611.00 -8.47962540e+00 -2.49412418e+00 8.83881793e+00 -2.85552854 0.93285743 611.25 -8.25673004e+00 -3.49354201e+00 8.96540165e+00 -2.74132014 0.95424969 611.50 -8.39881842e+00 -3.98140568e+00 9.29471581e+00 -2.69892499 0.94828545 611.75 -9.08730508e+00 -4.88543420e+00 1.03172952e+01 -2.64831096 0.94690811 612.00 -9.67394634e+00 -5.58292390e+00 1.11693454e+01 -2.61817466 0.94805933 612.25 -1.10832382e+01 -5.86776793e+00 1.25406886e+01 -2.65468135 0.95906636 612.50 -1.26894387e+01 -5.11402721e+00 1.36811962e+01 -2.75849031 0.95356369 612.75 -1.46238178e+01 -4.27798934e+00 1.52367070e+01 -2.85699780 0.95912408 613.00 -1.53121293e+01 -3.44833381e+00 1.56956144e+01 -2.92008523 0.95724602 613.25 -1.56826756e+01 -1.51302601e+00 1.57554930e+01 -3.04541278 0.95941912 613.50 -1.58606970e+01 3.15414444e-02 1.58607284e+01 3.13960400 0.95430973 613.75 -1.57816117e+01 1.74418698e+00 1.58777031e+01 3.03151917 0.96235187 614.00 -1.48299031e+01 2.64580070e+00 1.50640727e+01 2.96504039 0.96025092 614.25 -1.37540144e+01 3.08789743e+00 1.40963834e+01 2.92074578 0.96579792 614.50 -1.28921276e+01 2.91197462e+00 1.32169039e+01 2.91944809 0.96195485 614.75 -1.20567944e+01 2.35871876e+00 1.22853509e+01 2.94839869 0.95517468 615.00 -1.24221322e+01 2.25271058e+00 1.26247406e+01 2.96219575 0.96255707 615.25 -1.31779585e+01 2.39620359e+00 1.33940428e+01 2.96172365 0.97073719 615.50 -1.33306022e+01 2.78659827e+00 1.36187402e+01 2.93552230 0.97771188 615.75 -1.32956308e+01 3.39826355e+00 1.37230461e+01 2.89135742 0.97930201 616.00 -1.36477180e+01 4.39254151e+00 1.43371764e+01 2.83021090 0.98429097 616.25 -1.35236904e+01 5.11201902e+00 1.44576257e+01 2.78019030 0.98460628 616.50 -1.25189211e+01 6.23780906e+00 1.39869098e+01 2.67932960 0.98302142 616.75 -1.16667452e+01 6.69530519e+00 1.34513960e+01 2.62060091 0.98798171 617.00 -1.08824181e+01 6.61142567e+00 1.27333410e+01 2.59565275 0.98759403 617.25 -1.05029457e+01 6.38199298e+00 1.22899025e+01 2.59557562 0.98914577 617.50 -1.02797327e+01 6.12150580e+00 1.19643528e+01 2.60449394 0.98479651 617.75 -1.02200688e+01 5.83669745e+00 1.17693179e+01 2.62269308 0.98508016 618.00 -1.00044710e+01 5.66879700e+00 1.14988999e+01 2.62607415 0.98022390 618.25 -1.00306723e+01 5.55428785e+00 1.14657969e+01 2.63588995 0.98123445 618.50 -1.00794021e+01 5.26018889e+00 1.13694298e+01 2.66059851 0.96412933 618.75 -1.02993215e+01 4.92115691e+00 1.14146314e+01 2.69585110 0.97036251 619.00 -1.05403783e+01 4.74354261e+00 1.15585800e+01 2.71870935 0.94583352 619.25 -1.09787474e+01 4.15240003e+00 1.17377732e+01 2.78000051 0.93560667 619.50 -1.27730810e+01 3.78369446e+00 1.33217094e+01 2.85360358 0.94703874 619.75 -1.37787364e+01 3.68750431e+00 1.42636344e+01 2.88009780 0.94115474 620.00 -1.62394542e+01 4.79902321e+00 1.69337089e+01 2.85425442 0.93495085 620.25 -1.74622780e+01 6.04334392e+00 1.84784512e+01 2.80841436 0.93539078 620.50 -1.86858251e+01 8.91459406e+00 2.07033825e+01 2.69645031 0.95647817 620.75 -1.89021261e+01 1.06195009e+01 2.16809633e+01 2.62972358 0.96258639 621.00 -1.79223584e+01 1.39219855e+01 2.26943299e+01 2.48116257 0.96591900 621.25 -1.71513774e+01 1.57785948e+01 2.33052311e+01 2.39785830 0.95135399 621.50 -1.60208953e+01 1.95978040e+01 2.53129020e+01 2.25610782 0.96654196 621.75 -1.44825252e+01 2.11318241e+01 2.56183045e+01 2.17161677 0.96556380 622.00 -1.15088502e+01 2.39272789e+01 2.65512393e+01 2.01912292 0.97400295 622.25 -9.33353539e+00 2.43987021e+01 2.61230080e+01 1.93616296 0.96592441 622.50 -5.85885134e+00 2.44720930e+01 2.51636538e+01 1.80578289 0.95875835 622.75 -3.92772232e+00 2.43728173e+01 2.46872685e+01 1.73057439 0.95077231 623.00 -2.23459504e-01 2.35264309e+01 2.35274921e+01 1.58029427 0.93273511 623.25 1.51627411e+00 2.29402687e+01 2.29903244e+01 1.50479571 0.94207734 623.50 2.31163114e+00 2.19481872e+01 2.20695845e+01 1.46586100 0.94667830 623.75 3.88833198e+00 2.04243503e+01 2.07911811e+01 1.38267028 0.92654376 624.00 5.02716010e+00 1.85761521e+01 1.92443697e+01 1.30650261 0.92303088 624.25 5.46766510e+00 1.73015396e+01 1.81449341e+01 1.26470614 0.89908568 624.50 7.18814491e+00 1.56284394e+01 1.72022541e+01 1.13970708 0.90746622 624.75 7.60005610e+00 1.57300804e+01 1.74698679e+01 1.12071586 0.91907978 625.00 8.26975874e+00 1.54873457e+01 1.75569583e+01 1.08034442 0.92838592 625.25 8.64055068e+00 1.39924000e+01 1.64452538e+01 1.01759585 0.92969743 625.50 8.84296838e+00 1.29046347e+01 1.56437747e+01 0.97003488 0.92922076 625.75 9.74039504e+00 1.27705900e+01 1.60612349e+01 0.91920347 0.92599151 626.00 1.02709621e+01 1.21167792e+01 1.58842376e+01 0.86765977 0.94462026 626.25 1.08979592e+01 1.08663911e+01 1.53897359e+01 0.78394771 0.92523921 626.50 1.16557905e+01 1.00190708e+01 1.53700758e+01 0.71002886 0.94038313 626.75 1.20181088e+01 9.12974451e+00 1.50926198e+01 0.64965848 0.92161803 627.00 1.24674352e+01 8.32604707e+00 1.49919979e+01 0.58880311 0.91672313 627.25 1.30278823e+01 5.67071275e+00 1.42085432e+01 0.41054146 0.90637124 627.50 1.32846288e+01 4.56908801e+00 1.40484137e+01 0.33126416 0.90409333 627.75 1.23836663e+01 2.32788040e+00 1.26005642e+01 0.18581151 0.85033949 628.00 1.14136189e+01 1.64912715e+00 1.15321427e+01 0.14349460 0.82637700 628.25 8.94428555e+00 -7.47248226e-01 8.97544561e+00 -0.08335120 0.65828122 628.50 7.71380741e+00 -2.38106919e+00 8.07293721e+00 -0.29939753 0.62546810 628.75 4.01607208e+00 -2.09323751e+00 4.52884955e+00 -0.48047531 0.34222772 629.00 1.89362883e+00 -1.58066629e+00 2.46664470e+00 -0.69556119 0.15122208 629.25 -1.32569876e+00 2.05677354e+00 2.44699706e+00 2.14333256 0.12864967 629.50 -1.71188644e+00 4.77724748e+00 5.07470675e+00 1.91488299 0.28274048 629.75 2.07046026e+00 6.06284524e+00 6.40662924e+00 1.24171407 0.46005925 630.00 3.35030913e+00 5.65499967e+00 6.57294397e+00 1.03594619 0.43716912 630.25 6.26617619e+00 3.02420347e+00 6.95778489e+00 0.44964997 0.32690884 630.50 6.39763256e+00 2.50413112e+00 6.87025291e+00 0.37308392 0.32064939 630.75 4.66196844e+00 2.30247291e+00 5.19955106e+00 0.45874307 0.19975893 631.00 4.77488334e+00 2.35102469e+00 5.32229537e+00 0.45752759 0.27707326 631.25 4.27222029e+00 3.70774963e+00 5.65679004e+00 0.71477985 0.28567168 631.50 4.84795528e+00 4.45623157e+00 6.58488194e+00 0.74332114 0.33712426 631.75 7.13526347e+00 4.83332029e+00 8.61817671e+00 0.59538631 0.63171971 632.00 7.26678814e+00 2.93783218e+00 7.83818013e+00 0.38419236 0.59192735 632.25 7.04351420e+00 2.59490281e+00 7.50630488e+00 0.35298087 0.53926705 632.50 7.35675038e+00 1.25906905e+00 7.46371429e+00 0.16950252 0.55161379 632.75 7.80073914e+00 3.10771482e-02 7.80080104e+00 0.00398385 0.64198165 633.00 7.46718817e+00 -1.03317437e+00 7.53832530e+00 -0.13748897 0.68403909 633.25 7.60872911e+00 -1.04758368e+00 7.68050716e+00 -0.13682161 0.77083037 633.50 7.22141914e+00 -9.89207424e-01 7.28885627e+00 -0.13613514 0.76032522 633.75 6.45561266e+00 -1.36821408e+00 6.59901088e+00 -0.20885124 0.73208206 634.00 5.72477996e+00 -1.63645191e+00 5.95408099e+00 -0.27842893 0.72269390 634.25 5.19614903e+00 -2.06993170e+00 5.59326219e+00 -0.37909075 0.78861945 634.50 4.53196094e+00 -2.03658144e+00 4.96853438e+00 -0.42233984 0.66212377 634.75 4.23945287e+00 -1.02322486e+00 4.36118674e+00 -0.23682840 0.59474193 635.00 4.26743325e+00 2.25852498e-01 4.27340566e+00 0.05287534 0.58617574 635.25 3.81944583e+00 1.11259723e+00 3.97819545e+00 0.28345438 0.61486319 635.50 4.99242066e+00 2.08786464e+00 5.41141782e+00 0.39610277 0.56934717 635.75 7.03807433e+00 2.61419922e+00 7.50789770e+00 0.35564304 0.75140425 636.00 8.69663222e+00 2.52189069e+00 9.05490721e+00 0.28224335 0.73698411 636.25 1.00824567e+01 2.68425745e+00 1.04336557e+01 0.26019513 0.73942832 636.50 1.06814447e+01 1.27511901e+00 1.07572854e+01 0.11881474 0.66458999 636.75 1.12321096e+01 5.65372917e-02 1.12322519e+01 0.00503350 0.60299840 637.00 1.50498899e+01 -2.13015975e+00 1.51998936e+01 -0.14060591 0.67616151 637.25 1.79783742e+01 -3.45495189e+00 1.83073382e+01 -0.18985806 0.80045646 637.50 1.66661108e+01 -5.68250962e+00 1.76082414e+01 -0.32860052 0.69840400 637.75 1.65626149e+01 -7.62241521e+00 1.82324278e+01 -0.43131874 0.66840510 638.00 1.67711733e+01 -1.03894345e+01 1.97284719e+01 -0.55462124 0.56487640 638.25 1.49425950e+01 -1.58609915e+01 2.17911036e+01 -0.81520393 0.49199583 638.50 4.06946781e+00 -2.22039223e+01 2.25737621e+01 -1.38953107 0.41626136 638.75 -5.21910086e+00 -2.66838914e+01 2.71895030e+01 -1.76394788 0.53964359 639.00 -1.43766410e+01 -2.34023867e+01 2.74656060e+01 -2.12168145 0.62732991 639.25 -1.85891884e+01 -1.92667159e+01 2.67724535e+01 -2.33829886 0.67262792 639.50 -1.97186991e+01 -1.26469733e+01 2.34259051e+01 -2.57130847 0.81757844 639.75 -2.01712672e+01 -8.65060195e+00 2.19479597e+01 -2.73645910 0.83295809 640.00 -1.81767052e+01 -4.31525326e+00 1.86819170e+01 -2.90850213 0.85996577 640.25 -1.68330344e+01 -3.24448232e+00 1.71428619e+01 -2.95118274 0.87148986 640.50 -1.43146641e+01 -1.91049519e+00 1.44415927e+01 -3.00891254 0.82671949 640.75 -1.28419425e+01 -1.77515215e+00 1.29640523e+01 -3.00423231 0.82936506 641.00 -1.05723818e+01 -6.39338227e-01 1.05916954e+01 -3.08119372 0.85497296 641.25 -9.59851108e+00 -7.18853325e-01 9.62539169e+00 -3.06684003 0.82973302 641.50 -8.86422638e+00 -1.00783418e+00 8.92133616e+00 -3.02838201 0.74404597 641.75 -8.44024466e+00 -1.18279105e+00 8.52271815e+00 -3.00236229 0.75063522 642.00 -7.87708307e+00 -1.30756761e+00 7.98487136e+00 -2.97709618 0.79079595 642.25 -7.79981819e+00 -1.55256359e+00 7.95283707e+00 -2.94510952 0.81022155 642.50 -7.61211787e+00 -1.25675529e+00 7.71516509e+00 -2.97796937 0.85869097 642.75 -7.22517157e+00 -6.53858177e-01 7.25469743e+00 -3.05134124 0.84956081 643.00 -6.21232731e+00 2.90484358e-02 6.21239522e+00 3.13691675 0.87090134 643.25 -5.66385599e+00 7.18019494e-02 5.66431109e+00 3.12891611 0.83847130 643.50 -4.57295835e+00 1.61303963e-01 4.57580234e+00 3.10633383 0.76709055 643.75 -4.43575866e+00 2.37523409e-01 4.44211349e+00 3.08809633 0.72848420 644.00 -3.55492988e+00 2.73840139e-01 3.56546138e+00 3.06471338 0.54419446 644.25 -2.96762746e+00 -9.21893365e-02 2.96905905e+00 -3.11053764 0.46460752 644.50 -2.40043346e+00 -7.62832888e-01 2.51872881e+00 -2.83389604 0.44006930 644.75 -2.32880064e+00 -1.19258391e+00 2.61640380e+00 -2.66831023 0.39545488 645.00 -2.30690611e+00 -1.30721254e+00 2.65153171e+00 -2.62605489 0.49129700 645.25 -1.70990299e+00 -1.33490843e+00 2.16927379e+00 -2.47873596 0.27625776 645.50 -1.06789277e+00 -2.70058014e+00 2.90405373e+00 -1.94735761 0.39259524 645.75 -1.24105809e+00 -3.22706630e+00 3.45748204e+00 -1.93793743 0.49444825 646.00 -1.70007931e+00 -3.64932296e+00 4.02589465e+00 -2.00676216 0.64155220 646.25 -1.35546087e+00 -4.26348594e+00 4.47376648e+00 -1.87861420 0.62932918 646.50 -3.14535593e-01 -5.10866427e+00 5.11833793e+00 -1.63228775 0.68150180 646.75 -6.50822241e-01 -7.60333147e+00 7.63113485e+00 -1.65618517 0.72836918 647.00 -2.10314045e+00 -9.87081406e+00 1.00923818e+01 -1.78072374 0.81565565 647.25 -3.17523101e+00 -1.00163327e+01 1.05075693e+01 -1.87778043 0.78454406 647.50 -5.35309919e+00 -1.04489074e+01 1.17403295e+01 -2.04424484 0.78600829 647.75 -6.90466824e+00 -9.92328375e+00 1.20890861e+01 -2.17870115 0.77655583 648.00 -7.90890778e+00 -9.48205830e+00 1.23474796e+01 -2.26598210 0.78386081 648.25 -1.09439901e+01 -8.84403753e+00 1.40708180e+01 -2.46192116 0.84375649 648.50 -1.28892643e+01 -8.75213573e+00 1.55798913e+01 -2.54508285 0.87003845 648.75 -1.35220999e+01 -5.43701690e+00 1.45742354e+01 -2.75929121 0.83400675 649.00 -1.31351385e+01 -3.46725152e+00 1.35850542e+01 -2.88351179 0.81477981 649.25 -1.20836921e+01 -2.33928803e+00 1.23080414e+01 -2.95036760 0.82452558 649.50 -1.10158142e+01 -1.49471923e+00 1.11167598e+01 -3.00672782 0.84420633 649.75 -9.46370064e+00 -1.64790743e+00 9.60610372e+00 -2.96919195 0.78825376 650.00 -9.24980561e+00 -1.85999644e+00 9.43496108e+00 -2.94315412 0.83656018 650.25 -8.52448684e+00 -2.63419917e+00 8.92221279e+00 -2.84188535 0.88402534 650.50 -9.21495227e+00 -2.83988812e+00 9.64262982e+00 -2.84264588 0.90036951 650.75 -9.47931027e+00 -2.82651570e+00 9.89173969e+00 -2.85180885 0.91281485 651.00 -9.26504010e+00 -2.28620851e+00 9.54294071e+00 -2.89966906 0.90533014 651.25 -8.85043846e+00 -1.09792743e+00 8.91827929e+00 -3.01816975 0.87813944 651.50 -7.91649102e+00 -3.76403113e-01 7.92543434e+00 -3.09408172 0.81842412 651.75 -7.32801720e+00 3.98451055e-02 7.32812552e+00 3.13615534 0.78479464 652.00 -6.78894730e+00 5.52515469e-02 6.78917213e+00 3.13345438 0.73133884 652.25 -4.61888888e+00 -1.46959161e+00 4.84704384e+00 -2.83355066 0.60670338 652.50 -4.41127238e+00 -7.53955095e-01 4.47523991e+00 -2.97231279 0.58363016 652.75 -2.87691396e+00 4.75923356e-01 2.91601388e+00 2.97764899 0.39158662 653.00 -1.10680789e+00 -1.13913922e-02 1.10686651e+00 -3.13130090 0.06553965 653.25 1.49086510e+00 -2.42638304e+00 2.84780853e+00 -1.01982729 0.30642285 653.50 2.69464834e+00 -3.95544191e+00 4.78608926e+00 -0.97276479 0.46729623 653.75 4.51753038e+00 -6.11241735e+00 7.60063988e+00 -0.93432443 0.74700708 654.00 4.88794811e+00 -7.48305064e+00 8.93801340e+00 -0.99217301 0.77741461 654.25 5.54444327e+00 -9.82922596e+00 1.12851466e+01 -1.05720949 0.84214325 654.50 4.89403350e+00 -1.11787763e+01 1.22031391e+01 -1.15813672 0.84077166 654.75 1.79463485e+00 -1.19690528e+01 1.21028484e+01 -1.42196546 0.76812303 655.00 -7.10957876e-01 -1.04082409e+01 1.04324944e+01 -1.63899759 0.75746367 655.25 -1.77195917e+00 -7.97873203e+00 8.17312695e+00 -1.78933480 0.77225626 655.50 -6.01337645e-01 -5.98351978e+00 6.01366078e+00 -1.67095900 0.57467301 655.75 9.86810031e-01 -4.11433892e+00 4.23102574e+00 -1.33539644 0.30389702 656.00 3.13789574e+00 -3.27281916e+00 4.53406384e+00 -0.80644161 0.25030478 656.25 4.08868897e+00 -3.32062289e+00 5.26724917e+00 -0.68210483 0.24511379 656.50 3.78746667e+00 -3.24294664e+00 4.98614147e+00 -0.70810042 0.16426959 656.75 5.91897539e+00 -3.15075961e+00 6.70533786e+00 -0.48916420 0.23724254 657.00 9.28346892e+00 -7.60384026e-01 9.31455737e+00 -0.08172488 0.22251174 657.25 9.40234544e+00 -1.22824562e+00 9.48223007e+00 -0.12989629 0.17756432 657.50 9.63879434e+00 -3.40914944e+00 1.02239257e+01 -0.33995873 0.22243786 657.75 8.55625780e+00 -3.84573106e+00 9.38078861e+00 -0.42240822 0.23066796 658.00 3.87632374e+00 -6.31197710e+00 7.40722219e+00 -1.02005769 0.25856482 658.25 1.90148060e+00 -5.48108735e+00 5.80154695e+00 -1.23687098 0.21632195 658.50 4.96981454e-01 -5.44622474e+00 5.46885313e+00 -1.47979589 0.25756682 658.75 1.42553910e+00 -4.61144746e+00 4.82675972e+00 -1.27098411 0.22283250 659.00 3.61120321e+00 -3.29958915e+00 4.89163338e+00 -0.74033776 0.21183543 659.25 4.45898974e+00 -3.24811703e+00 5.51659803e+00 -0.62956087 0.25330810 659.50 3.92867461e+00 -3.52603786e+00 5.27896081e+00 -0.73143956 0.21882966 659.75 3.85803804e+00 -4.37781029e+00 5.83521041e+00 -0.84842553 0.20663232 660.00 3.55168600e+00 -7.32251698e+00 8.13841068e+00 -1.11919124 0.28969731 660.25 3.32492017e+00 -6.92441159e+00 7.68131304e+00 -1.12313521 0.32663021 660.50 3.14424779e+00 -6.84951003e+00 7.53671559e+00 -1.14044434 0.34317466 660.75 4.13922062e+00 -6.91081381e+00 8.05558780e+00 -1.03115045 0.38996889 661.00 7.77341903e+00 -6.03818359e+00 9.84305362e+00 -0.66041694 0.49899221 661.25 8.84359457e+00 -6.19775000e+00 1.07991328e+01 -0.61127473 0.55736996 661.50 1.20661778e+01 -8.51757840e+00 1.47696238e+01 -0.61467824 0.60177905 661.75 1.20054215e+01 -7.75659176e+00 1.42931753e+01 -0.57362216 0.51793079 662.00 1.19267919e+01 -6.18005477e+00 1.34328494e+01 -0.47807435 0.36538820 662.25 1.11600462e+01 -8.88008391e+00 1.42619256e+01 -0.67211541 0.48529174 662.50 1.00576918e+01 -1.14838560e+01 1.52655204e+01 -0.85150697 0.43333893 662.75 1.08296606e+01 -1.07378133e+01 1.52506454e+01 -0.78113959 0.42857779 663.00 8.94855322e+00 -1.54996465e+01 1.78973642e+01 -1.04720587 0.68918596 663.25 7.75532814e+00 -1.54463869e+01 1.72839806e+01 -1.10548578 0.74809908 663.50 6.31318122e+00 -1.29409948e+01 1.43988056e+01 -1.11692106 0.74066124 663.75 6.71404938e+00 -1.19870554e+01 1.37392851e+01 -1.06022555 0.76606287 664.00 7.25641784e+00 -8.83943300e+00 1.14363970e+01 -0.88343216 0.79050446 664.25 7.51051411e+00 -7.32285312e+00 1.04896139e+01 -0.77274756 0.73510920 664.50 8.29004036e+00 -4.11854690e+00 9.25673796e+00 -0.46108964 0.51583197 664.75 8.41060898e+00 -2.27938526e+00 8.71400830e+00 -0.26465586 0.50183040 665.00 5.81068605e+00 -1.01625004e+00 5.89888435e+00 -0.17314213 0.32613594 665.25 3.94712266e+00 7.63945202e-01 4.02037182e+00 0.19118104 0.14075800 665.50 2.50973907e+00 3.49265863e+00 4.30086672e+00 0.94771204 0.19061594 665.75 1.26626199e+00 5.03489041e+00 5.19167997e+00 1.32440882 0.27599996 666.00 1.40183192e+00 4.04201558e+00 4.27820320e+00 1.23696167 0.22854689 666.25 1.33994930e+00 1.36894497e+00 1.91558724e+00 0.79610163 0.08699699 666.50 6.00761237e-01 6.49270510e-01 8.84571229e-01 0.82418513 0.03839906 666.75 -6.08349363e-01 5.02430176e-01 7.89002553e-01 2.45126277 0.03396525 667.00 -1.97013903e+00 2.39074117e-01 1.98459170e+00 3.02083423 0.20022721 667.25 -1.68451618e+00 7.20115124e-01 1.83198268e+00 2.73761419 0.15242397 667.50 -1.88851859e+00 1.12073551e+00 2.19603063e+00 2.60600554 0.21342501 667.75 -1.75745591e+00 7.76144498e-01 1.92121096e+00 2.72572134 0.23166485 668.00 -1.73417820e+00 3.84168633e-01 1.77622059e+00 2.92358558 0.29529902 668.25 -1.94074580e+00 2.96134768e-01 1.96320913e+00 2.99017250 0.39618041 668.50 -1.69113348e+00 4.49188564e-01 1.74977222e+00 2.88197339 0.36382979 668.75 -1.89616379e+00 -2.42159608e-01 1.91156438e+00 -3.01456997 0.35333852 669.00 -1.89394557e+00 -7.78671290e-01 2.04776923e+00 -2.75152235 0.35896925 669.25 -1.62634487e+00 -7.58794213e-01 1.79464935e+00 -2.70504968 0.37448520 669.50 -1.51599460e+00 -7.48046561e-01 1.69050681e+00 -2.68320989 0.32097628 669.75 -1.16137009e+00 -1.06033758e+00 1.57260811e+00 -2.40163834 0.18822016 670.00 -1.74648179e-01 -1.65508370e+00 1.66427282e+00 -1.67592952 0.13049771 670.25 1.04785615e+00 -4.06549458e+00 4.19836263e+00 -1.31854274 0.24450486 670.50 9.52817355e-01 -5.63569074e+00 5.71566890e+00 -1.40331172 0.28727181 670.75 -8.99364226e-01 -6.82551829e+00 6.88451566e+00 -1.70180658 0.42762323 671.00 -2.11448832e+00 -7.88123088e+00 8.15995472e+00 -1.83291756 0.60002667 671.25 -2.75646539e+00 -9.18594314e+00 9.59060232e+00 -1.86232128 0.83160340 671.50 -3.16447672e+00 -9.06203822e+00 9.59866916e+00 -1.90675955 0.85954257 671.75 -2.69142497e+00 -9.05517338e+00 9.44668901e+00 -1.85970542 0.82077012 672.00 -2.38052761e+00 -8.83478979e+00 9.14988647e+00 -1.83399478 0.79642094 672.25 -2.06642430e+00 -8.75016594e+00 8.99085721e+00 -1.80270568 0.85328140 672.50 -1.89606631e+00 -8.56012127e+00 8.76759623e+00 -1.78877687 0.88860088 672.75 -2.53274505e+00 -8.62437902e+00 8.98858782e+00 -1.85643824 0.84066375 673.00 -2.52458141e+00 -8.89174543e+00 9.24319469e+00 -1.84744019 0.81511817 673.25 -1.67779077e+00 -1.03116261e+01 1.04472300e+01 -1.73209151 0.79536749 673.50 -1.76899007e+00 -1.06087474e+01 1.07552242e+01 -1.73602438 0.79510218 673.75 -2.88767165e+00 -9.79614732e+00 1.02128914e+01 -1.85745383 0.78616512 674.00 -2.59872221e+00 -1.01270607e+01 1.04551765e+01 -1.82198802 0.77619125 674.25 -1.02089131e+00 -1.02101332e+01 1.02610448e+01 -1.67045315 0.76599984 674.50 1.91182079e-01 -1.12686674e+01 1.12702890e+01 -1.55383214 0.78888185 674.75 1.97386541e+00 -1.15089742e+01 1.16770130e+01 -1.40094222 0.73195790 675.00 4.80180418e+00 -1.28282647e+01 1.36975070e+01 -1.21262687 0.68751215 675.25 6.22493070e+00 -1.21362777e+01 1.36396114e+01 -1.09686680 0.69597306 675.50 6.35125549e+00 -1.15568303e+01 1.31870684e+01 -1.06828542 0.74280431 675.75 8.88402560e+00 -1.05175299e+01 1.37675105e+01 -0.86939456 0.71186728 676.00 1.02689213e+01 -8.45603646e+00 1.33024546e+01 -0.68888248 0.69186465 676.25 1.11104944e+01 -6.52848382e+00 1.28865894e+01 -0.53124910 0.74948876 676.50 1.00675469e+01 -4.40412535e+00 1.09887133e+01 -0.41237489 0.71838544 676.75 8.73912640e+00 -3.69781083e+00 9.48926421e+00 -0.40028803 0.73032986 677.00 7.84255843e+00 -2.46552120e+00 8.22098033e+00 -0.30459410 0.69533120 677.25 6.74740588e+00 -1.88992866e+00 7.00709044e+00 -0.27309872 0.74542310 677.50 5.16469954e+00 -1.94402970e+00 5.51845747e+00 -0.36000374 0.69595529 677.75 4.01929464e+00 -1.77827205e+00 4.39510874e+00 -0.41654414 0.68774416 678.00 2.82140206e+00 -8.41462394e-01 2.94420932e+00 -0.28984376 0.65297346 678.25 2.11118862e+00 -2.61904602e-01 2.12737194e+00 -0.12342494 0.60278902 678.50 7.29133954e-01 2.15137330e-01 7.60210756e-01 0.28691737 0.16211669 678.75 -3.04098045e-01 8.20004482e-01 8.74575881e-01 1.92592302 0.27767411 679.00 -1.32920756e+00 1.64733632e+00 2.11672145e+00 2.24972011 0.70570278 679.25 -1.89374365e+00 2.26773581e+00 2.95446962e+00 2.26656527 0.86480816 679.50 -2.08517776e+00 3.15176892e+00 3.77910222e+00 2.15527584 0.90445435 679.75 -2.03056219e+00 3.53699753e+00 4.07842302e+00 2.09194800 0.92026105 680.00 -1.77442427e+00 3.95107331e+00 4.33123097e+00 1.99290098 0.86881544 680.25 -1.55854543e+00 4.23450616e+00 4.51221745e+00 1.92346734 0.85632586 680.50 -1.12954909e+00 5.12714534e+00 5.25009529e+00 1.78764001 0.85983405 680.75 -7.27498212e-01 5.37656154e+00 5.42555690e+00 1.70528870 0.85814456 681.00 -4.45183821e-02 5.24807752e+00 5.24826634e+00 1.57927892 0.84516251 681.25 3.00645524e-01 5.26784405e+00 5.27641627e+00 1.51378634 0.86170293 681.50 7.32017691e-01 5.39474401e+00 5.44418155e+00 1.43592912 0.77711165 681.75 9.02567932e-01 5.49535862e+00 5.56898511e+00 1.40800784 0.73511207 682.00 2.10837286e+00 5.45274781e+00 5.84616924e+00 1.20184044 0.76092054 682.25 2.72852759e+00 5.23609881e+00 5.90437071e+00 1.09041208 0.72897334 682.50 3.47597870e+00 4.19237738e+00 5.44595777e+00 0.87855051 0.74110838 682.75 3.49241780e+00 3.74863623e+00 5.12340274e+00 0.82076754 0.75623003 683.00 4.14560078e+00 3.05365348e+00 5.14886447e+00 0.63487042 0.75823228 683.25 4.76139470e+00 3.14229477e+00 5.70481340e+00 0.58333998 0.79817939 683.50 5.05314070e+00 2.62932351e+00 5.69627712e+00 0.47978257 0.82535668 683.75 4.75962876e+00 2.30481171e+00 5.28831003e+00 0.45096185 0.80980635 684.00 4.71076854e+00 2.06317685e+00 5.14276569e+00 0.41280514 0.79962892 684.25 4.64715912e+00 1.54391707e+00 4.89691411e+00 0.32075556 0.79627954 684.50 4.88094078e+00 1.08869818e+00 5.00088459e+00 0.21945848 0.75271962 684.75 5.10851573e+00 1.29165629e+00 5.26927973e+00 0.24765334 0.76166336 685.00 5.22491519e+00 1.31066779e+00 5.38679764e+00 0.24577811 0.81714967 685.25 4.72383136e+00 1.39870334e+00 4.92655598e+00 0.28787048 0.75905732 685.50 4.44522088e+00 1.56745503e+00 4.71348108e+00 0.33900323 0.70290618 685.75 4.61934753e+00 2.06347720e+00 5.05927957e+00 0.42010890 0.63059921 686.00 5.06558714e+00 3.23650198e+00 6.01124930e+00 0.56854623 0.64803175 686.25 5.77476041e+00 3.68036746e+00 6.84784364e+00 0.56740928 0.64101480 686.50 7.00803701e+00 3.11235049e+00 7.66807070e+00 0.41794635 0.66545626 686.75 7.57549733e+00 2.92753730e+00 8.12149213e+00 0.36876948 0.61121466 687.00 9.17541127e+00 2.44382659e+00 9.49528621e+00 0.26030223 0.65411035 687.25 1.16496444e+01 1.29231343e+00 1.17211044e+01 0.11047987 0.69881180 687.50 1.51997423e+01 5.56534166e-01 1.52099276e+01 0.03659836 0.74614045 687.75 1.68744949e+01 -3.18197191e+00 1.71718817e+01 -0.18637846 0.72563640 688.00 2.15884922e+01 -4.50719695e+00 2.20539751e+01 -0.20582129 0.72710593 688.25 2.41905502e+01 -8.18550381e+00 2.55379168e+01 -0.32628215 0.56026509 688.50 2.25958612e+01 -2.18938342e+01 3.14628817e+01 -0.76961993 0.47809641 688.75 -1.83430078e+00 -2.71245322e+01 2.71864839e+01 -1.63831868 0.60513400 689.00 -5.81934576e+00 -2.65526597e+01 2.71828718e+01 -1.78654760 0.81634767 689.25 -6.01546377e+00 -2.05898197e+01 2.14505590e+01 -1.85504244 0.85573975 689.50 -6.01106686e+00 -1.79126070e+01 1.88942958e+01 -1.89456522 0.89666583 689.75 -5.73538424e+00 -1.66230534e+01 1.75846677e+01 -1.90303304 0.91247028 690.00 -4.59550906e+00 -1.65478095e+01 1.71740707e+01 -1.84168120 0.89820115 690.25 -1.53090193e+00 -1.70271427e+01 1.70958255e+01 -1.66046473 0.73904598 690.50 -2.30966035e+00 -1.82282236e+01 1.83739671e+01 -1.69683261 0.65684259 690.75 -1.15045365e+01 -1.09221595e+01 1.58634148e+01 -2.38215668 0.56929612 691.00 -1.21620685e+01 -7.12667184e+00 1.40962889e+01 -2.61154926 0.61509613 691.25 -1.08987824e+01 -6.49871642e+00 1.26892384e+01 -2.60391358 0.77583877 691.50 -1.01670476e+01 -6.68187618e+00 1.21661960e+01 -2.56016621 0.85326311 691.75 -8.62387806e+00 -7.18617549e+00 1.12255241e+01 -2.44688104 0.80658442 692.00 -9.13841702e+00 -8.23314957e+00 1.23002202e+01 -2.40825942 0.88404686 692.25 -9.03233843e+00 -7.62686387e+00 1.18216830e+01 -2.44036144 0.91719519 692.50 -9.22886736e+00 -7.35901829e+00 1.18036919e+01 -2.46844442 0.91050044 692.75 -1.04228925e+01 -8.11997666e+00 1.32125209e+01 -2.47975595 0.89307513 693.00 -1.11323307e+01 -8.46668678e+00 1.39861922e+01 -2.49137408 0.88718697 693.25 -1.21291730e+01 -8.91041836e+00 1.50503287e+01 -2.50800306 0.91233804 693.50 -1.18991924e+01 -8.71729067e+00 1.47506588e+01 -2.50932402 0.90844535 693.75 -1.19166845e+01 -9.31099601e+00 1.51228971e+01 -2.47833306 0.87055379 694.00 -1.33018365e+01 -9.49487093e+00 1.63429320e+01 -2.52166386 0.84619256 694.25 -1.84641315e+01 -5.11741117e+00 1.91601683e+01 -2.87122483 0.83952879 694.50 -1.99249970e+01 -2.38977653e+00 2.00677985e+01 -3.02222424 0.82488927 694.75 -1.88595273e+01 2.23905377e+00 1.89919754e+01 3.02342310 0.81281850 695.00 -1.63776970e+01 5.79497954e+00 1.73727012e+01 2.80150669 0.80628763 695.25 -1.19549559e+01 7.89850859e+00 1.43285522e+01 2.55773982 0.89182110 695.50 -9.95560631e+00 7.07435910e+00 1.22131345e+01 2.52379429 0.87713549 695.75 -7.70663558e+00 6.23885266e+00 9.91541802e+00 2.46105985 0.89510469 696.00 -6.82894100e+00 5.04642762e+00 8.49122294e+00 2.50518393 0.90370319 696.25 -5.57987742e+00 4.16873541e+00 6.96515520e+00 2.49994910 0.93071710 696.50 -5.17153254e+00 3.33137845e+00 6.15165272e+00 2.56932236 0.92134096 696.75 -5.10934917e+00 2.28688807e+00 5.59779474e+00 2.72074559 0.92965152 697.00 -5.82285345e+00 1.65900626e+00 6.05457877e+00 2.86403402 0.92458522 697.25 -6.71015663e+00 1.11062521e+00 6.80144767e+00 2.97756565 0.94037306 697.50 -7.04540991e+00 1.41079299e+00 7.18527227e+00 2.94396359 0.93471684 697.75 -7.18408185e+00 2.02200267e+00 7.46321156e+00 2.86723435 0.94137692 698.00 -6.55967064e+00 3.58031746e+00 7.47314874e+00 2.64197395 0.92405075 698.25 -5.75732877e+00 4.67771030e+00 7.41807308e+00 2.45928858 0.93974499 698.50 -4.15142083e+00 4.68242714e+00 6.25774871e+00 2.29615631 0.89550137 698.75 -3.27017039e+00 4.33483212e+00 5.42998931e+00 2.21710353 0.86637339 699.00 -1.86206244e+00 2.61048683e+00 3.20654300e+00 2.19039336 0.66631350 699.25 -1.36323456e+00 1.49810623e+00 2.02551987e+00 2.30909352 0.63202301 699.50 -1.68775544e+00 5.85030691e-01 1.78627527e+00 2.80792108 0.48009887 699.75 -2.10623370e+00 5.24595047e-02 2.10688690e+00 3.11669102 0.56390242 700.00 -2.57730729e+00 -8.00229197e-01 2.69868109e+00 -2.84053963 0.64432579 700.25 -3.06953386e+00 -8.98215064e-01 3.19825397e+00 -2.85691776 0.78071724 700.50 -3.51398162e+00 -8.60310774e-01 3.61776194e+00 -2.90149042 0.79182287 700.75 -3.99556650e+00 -9.66584520e-01 4.11081954e+00 -2.90423846 0.82914878 701.00 -4.86502552e+00 -1.48894963e+00 5.08777400e+00 -2.84459307 0.85500835 701.25 -5.28434782e+00 -1.58554603e+00 5.51709055e+00 -2.85009390 0.86695952 701.50 -6.04502776e+00 -1.08633681e+00 6.14186358e+00 -2.96378305 0.90001022 701.75 -6.47054608e+00 -7.96871203e-01 6.51943021e+00 -3.01905604 0.91448422 702.00 -7.25415939e+00 1.26197447e-01 7.25525701e+00 3.12419784 0.89019943 702.25 -7.55704588e+00 5.73255094e-01 7.57875741e+00 3.06588062 0.90481450 702.50 -7.14728157e+00 1.20691715e+00 7.24846762e+00 2.97430699 0.85710061 702.75 -6.97507478e+00 2.43011060e+00 7.38627820e+00 2.80634463 0.82798512 703.00 -6.84751986e+00 3.89018401e+00 7.87540856e+00 2.62494745 0.90778119 703.25 -6.53076683e+00 4.32989534e+00 7.83574560e+00 2.55613314 0.89784591 703.50 -5.48766181e+00 5.16092042e+00 7.53322850e+00 2.38686889 0.86364707 703.75 -4.26950283e+00 5.31776202e+00 6.81962223e+00 2.24728839 0.82144401 704.00 -1.75564234e+00 4.81321396e+00 5.12340791e+00 1.92055469 0.75482013 704.25 -1.32912400e+00 4.60433143e+00 4.79233123e+00 1.85182481 0.83599200 704.50 -8.38166598e-01 3.95373772e+00 4.04160429e+00 1.77969703 0.76643066 704.75 -5.78053101e-01 3.34669834e+00 3.39625311e+00 1.74183219 0.74678616 705.00 -5.31599947e-01 2.83645786e+00 2.88584333e+00 1.75606393 0.82039512 705.25 -3.37240746e-01 2.52521003e+00 2.54762969e+00 1.70356033 0.75041287 705.50 -5.34822981e-01 2.01880730e+00 2.08844883e+00 1.82976756 0.72670599 705.75 -5.32375429e-01 1.96110502e+00 2.03208181e+00 1.83587504 0.78679596 706.00 -4.98947949e-01 1.76048788e+00 1.82982694e+00 1.84696856 0.84998887 706.25 -5.63327826e-01 1.66748461e+00 1.76006908e+00 1.89658921 0.81894933 706.50 -4.63561400e-01 1.48569572e+00 1.55633574e+00 1.87324054 0.79386597 706.75 -6.23662181e-01 1.46718070e+00 1.59423139e+00 1.97273070 0.82171393 707.00 -6.47404972e-01 1.35799569e+00 1.50442197e+00 2.01565985 0.83607072 707.25 -5.18501026e-01 1.36745774e+00 1.46245820e+00 1.93321919 0.82856020 707.50 -3.18642303e-01 1.25392785e+00 1.29378050e+00 1.81964449 0.80599566 707.75 -2.09435100e-01 1.24787387e+00 1.26532694e+00 1.73708013 0.78836064 708.00 -1.14559701e-01 1.23733822e+00 1.24263020e+00 1.66311873 0.82892580 708.25 3.29274701e-02 1.05099483e+00 1.05151051e+00 1.53947676 0.78120403 708.50 3.80674262e-02 1.11730560e+00 1.11795391e+00 1.53673876 0.84186767 708.75 2.33030869e-01 1.21868998e+00 1.24076938e+00 1.38186272 0.81445835 709.00 4.38599376e-01 1.17439429e+00 1.25362329e+00 1.21336894 0.86271265 709.25 6.00219528e-01 1.00731429e+00 1.17258073e+00 1.03342560 0.84242582 709.50 8.41852457e-01 9.01620339e-01 1.23354562e+00 0.81966568 0.85328769 709.75 1.10666844e+00 7.04975979e-01 1.31213801e+00 0.56720015 0.86259519 710.00 1.28973204e+00 5.74260709e-01 1.41180172e+00 0.41890167 0.92009773 710.25 1.37859660e+00 4.39197079e-01 1.44686650e+00 0.30841680 0.90260345 710.50 1.40735468e+00 3.59040027e-01 1.45243139e+00 0.24978878 0.91541833 710.75 1.65390261e+00 2.08538544e-01 1.66699795e+00 0.12542687 0.91334561 711.00 1.86281706e+00 8.57525273e-02 1.86478977e+00 0.04600131 0.95681867 711.25 2.00283758e+00 -2.41219640e-02 2.00298283e+00 -0.01204331 0.96086053 711.50 2.09447853e+00 -1.24968958e-01 2.09820341e+00 -0.05959525 0.96307521 711.75 2.26651327e+00 -2.91016328e-01 2.28511989e+00 -0.12769955 0.95180946 712.00 2.40680073e+00 -3.70210182e-01 2.43510685e+00 -0.15262219 0.96639359 712.25 2.67840047e+00 -5.65563714e-01 2.73746076e+00 -0.20810032 0.96185209 712.50 2.72422515e+00 -7.62483822e-01 2.82891928e+00 -0.27290685 0.96592411 712.75 2.86364521e+00 -8.46777455e-01 2.98621766e+00 -0.28750641 0.96596866 713.00 2.94139720e+00 -9.07137930e-01 3.07810278e+00 -0.29914871 0.95866433 713.25 3.15891629e+00 -1.00530916e+00 3.31502619e+00 -0.30811011 0.95855765 713.50 3.24635911e+00 -1.09152245e+00 3.42494799e+00 -0.32435504 0.95377727 713.75 3.44205109e+00 -1.20144549e+00 3.64570802e+00 -0.33582761 0.95949603 714.00 3.55105751e+00 -1.34242986e+00 3.79633078e+00 -0.36143027 0.95713261 714.25 4.02526538e+00 -1.42844206e+00 4.27120687e+00 -0.34100589 0.95034715 714.50 4.05625457e+00 -1.48794257e+00 4.32055254e+00 -0.35158587 0.94802402 714.75 4.27821529e+00 -1.78702521e+00 4.63644101e+00 -0.39567419 0.94617649 715.00 4.44548368e+00 -1.83480122e+00 4.80924326e+00 -0.39143534 0.94902432 715.25 4.41065960e+00 -2.24102726e+00 4.94733477e+00 -0.47010139 0.94727107 715.50 4.16816177e+00 -2.31149613e+00 4.76619207e+00 -0.50633749 0.92594055 715.75 4.56904241e+00 -2.11759481e+00 5.03590670e+00 -0.43399547 0.92847500 716.00 4.68587006e+00 -1.87464930e+00 5.04694841e+00 -0.38056180 0.93490533 716.25 4.56107926e+00 -1.50596740e+00 4.80326783e+00 -0.31890795 0.92221552 716.50 4.75023445e+00 -1.33385010e+00 4.93395211e+00 -0.27374732 0.92809923 716.75 4.87791437e+00 -9.57805639e-01 4.97106028e+00 -0.19388885 0.90630255 717.00 5.08364046e+00 -5.17404754e-01 5.10990294e+00 -0.10142913 0.87661672 717.25 5.21142660e+00 2.67944892e-01 5.21831023e+00 0.05136965 0.84270779 717.50 5.01407003e+00 3.33583398e-01 5.02515435e+00 0.06643157 0.72214541 717.75 4.82167297e+00 5.76635039e-01 4.85603112e+00 0.11902701 0.46624041 718.00 4.21684906e+00 9.10285777e-01 4.31398148e+00 0.21260634 0.31575822 718.25 3.51743818e+00 1.10838837e+00 3.68793928e+00 0.30526307 0.17148311 718.50 2.24934902e+00 1.20986680e+00 2.55408470e+00 0.49348593 0.07878167 718.75 1.64562869e+00 -8.33997638e-01 1.84489725e+00 -0.46906942 0.03751307 719.00 9.85935735e-01 -3.64673761e+00 3.77766654e+00 -1.30674802 0.15290653 719.25 1.95053198e-01 -4.91169276e+00 4.91556421e+00 -1.53110517 0.30049962 719.50 9.68442223e-01 -3.64734148e+00 3.77372233e+00 -1.31126475 0.27161122 719.75 1.92584888e+00 -2.95229244e+00 3.52490065e+00 -0.99278965 0.32608314 720.00 1.43608400e+00 -2.50869991e+00 2.89065952e+00 -1.05088693 0.28387434 720.25 1.22023080e+00 -2.05497889e+00 2.38995846e+00 -1.03495376 0.24990221 720.50 1.70131450e+00 -3.95793000e-01 1.74674644e+00 -0.22857385 0.22107967 720.75 1.59815529e+00 6.96270859e-01 1.74324222e+00 0.41087475 0.25740898 721.00 1.57108925e+00 1.64813547e+00 2.27698747e+00 0.80932676 0.32693785 721.25 1.64311403e+00 1.96994522e+00 2.56525006e+00 0.87561093 0.30556692 721.50 -1.69429382e-01 2.93074861e+00 2.93564196e+00 1.62854301 0.21041659 721.75 -1.90022419e+00 2.93395102e+00 3.49555726e+00 2.14552995 0.22837009 722.00 -3.38507856e+00 1.79927262e+00 3.83355433e+00 2.65303994 0.24878634 722.25 -2.64389011e+00 1.33548459e+00 2.96203883e+00 2.67385659 0.15863913 722.50 -1.62176280e+00 -4.94110748e-01 1.69536427e+00 -2.84585231 0.04538390 722.75 -9.11838828e-01 -1.34623405e+00 1.62597545e+00 -2.16614196 0.06099134 723.00 -7.11234765e-01 -1.81341367e+00 1.94790247e+00 -1.94456719 0.07846577 723.25 -2.21708077e-01 -1.73557978e+00 1.74968330e+00 -1.69785115 0.04765304 723.50 9.40768087e-01 -9.46543105e-01 1.33453679e+00 -0.78845807 0.04284814 723.75 2.43855489e-01 -1.90992871e-01 3.09747924e-01 -0.66442611 0.00312066 724.00 8.54166552e-01 3.84224052e-01 9.36604837e-01 0.42270701 0.04196996 724.25 1.45837699e+00 1.38808715e+00 2.01336768e+00 0.76070944 0.20169480 724.50 7.23486751e-01 2.29031463e+00 2.40186890e+00 1.26482634 0.30597380 724.75 4.44004700e-01 2.68604302e+00 2.72249284e+00 1.40697702 0.33690175 725.00 7.46233421e-01 2.72881992e+00 2.82901440e+00 1.30385888 0.26826425 725.25 7.10109364e-01 2.68988263e+00 2.78203592e+00 1.31269204 0.23842281 725.50 -2.28172946e-01 2.84138922e+00 2.85053602e+00 1.65092768 0.25073127 725.75 -7.46092851e-01 2.12164691e+00 2.24900870e+00 1.90894691 0.20237730 726.00 -9.79036756e-01 1.56015003e+00 1.84189605e+00 2.13121097 0.23008655 726.25 -8.03913797e-01 9.65242910e-01 1.25617326e+00 2.26525616 0.16299087 726.50 -4.40876789e-01 -2.50730081e-01 5.07186274e-01 -2.62449997 0.02610361 726.75 -4.46147362e-01 -1.55772006e+00 1.62035158e+00 -1.84973953 0.22088397 727.00 2.80049694e-01 -2.22219292e+00 2.23976990e+00 -1.44543319 0.45795811 727.25 8.68565062e-01 -2.73646182e+00 2.87099784e+00 -1.26344964 0.61668401 727.50 1.33122643e+00 -3.04784274e+00 3.32588472e+00 -1.15899321 0.68997929 727.75 1.81274317e+00 -3.67134597e+00 4.09448642e+00 -1.11215768 0.72901596 728.00 2.36244038e+00 -4.78771025e+00 5.33884762e+00 -1.11241171 0.81898143 728.25 3.05685038e+00 -4.20066914e+00 5.19518579e+00 -0.94171699 0.85562144 728.50 3.76901287e+00 -4.10620889e+00 5.57372492e+00 -0.82818936 0.92276717 728.75 4.62835137e+00 -3.78111190e+00 5.97649092e+00 -0.68498863 0.89278025 729.00 5.71021321e+00 -2.99760740e+00 6.44920034e+00 -0.48341206 0.91503642 729.25 6.53887011e+00 -2.11448010e+00 6.87225206e+00 -0.31275770 0.88682148 729.50 7.94679343e+00 -1.79705396e+00 8.14744922e+00 -0.22239519 0.87309073 729.75 8.94100414e+00 -1.29135277e+00 9.03377812e+00 -0.14343850 0.82808303 730.00 9.76333983e+00 -7.73612651e-01 9.79394105e+00 -0.07907127 0.82313476 730.25 1.07864912e+01 -2.47548312e+00 1.10669060e+01 -0.22559199 0.80931615 730.50 1.03994215e+01 -3.72342026e+00 1.10458963e+01 -0.34382034 0.82530369 730.75 1.05655270e+01 -1.46121016e+00 1.06660909e+01 -0.13742803 0.77207313 731.00 1.10994255e+01 -9.73973316e-01 1.11420765e+01 -0.08752569 0.79606595 731.25 9.57406834e+00 6.95069158e-01 9.59926589e+00 0.07247200 0.80743286 731.50 8.99780731e+00 1.52629113e+00 9.12634105e+00 0.16802978 0.78355657 731.75 8.93591856e+00 6.89553961e-01 8.96248432e+00 0.07701392 0.72610795 732.00 9.03353896e+00 5.36434306e-01 9.04945236e+00 0.05931287 0.73039526 732.25 8.82543813e+00 1.33678750e+00 8.92610548e+00 0.15032711 0.65985950 732.50 9.66814592e+00 2.39881165e+00 9.96129223e+00 0.24320372 0.70838017 732.75 8.64690416e+00 3.94699161e+00 9.50514042e+00 0.42821552 0.71914148 733.00 7.70203019e+00 4.49138344e+00 8.91592924e+00 0.52793228 0.72372218 733.25 8.85610694e+00 4.43771629e+00 9.90575368e+00 0.46452010 0.72585939 733.50 8.95369210e+00 5.21390881e+00 1.03611509e+01 0.52731762 0.70924613 733.75 7.13006072e+00 7.13396074e+00 1.00861867e+01 0.78567158 0.72763676 734.00 6.65297533e+00 7.09674888e+00 9.72758579e+00 0.81766205 0.71240672 734.25 5.36184883e+00 6.95258628e+00 8.77997032e+00 0.91386341 0.59131698 734.50 5.80408502e+00 7.33412150e+00 9.35290014e+00 0.90133296 0.67535160 734.75 4.93856324e+00 7.00104402e+00 8.56761485e+00 0.95645283 0.62437807 735.00 3.70643447e+00 6.26794755e+00 7.28181454e+00 1.03677515 0.50023958 735.25 2.40933503e+00 7.02337123e+00 7.42513560e+00 1.24033055 0.45264930 735.50 1.89118768e+00 6.10036489e+00 6.38678657e+00 1.27017951 0.33364917 735.75 2.28638037e-01 6.02321389e+00 6.02755182e+00 1.53285507 0.48688546 736.00 -3.95147801e-01 5.97519294e+00 5.98824452e+00 1.63683156 0.52970052 736.25 -1.45167191e+00 5.03612548e+00 5.24117460e+00 1.85144036 0.45143654 736.50 -2.28331271e+00 4.51275897e+00 5.05752019e+00 2.03920712 0.33830915 736.75 -4.66340388e+00 1.63031264e+00 4.94016752e+00 2.80527678 0.33982723 737.00 -5.85370989e+00 1.24179771e+00 5.98397703e+00 2.93255309 0.44651340 737.25 -8.66945022e+00 5.63086886e-01 8.68771742e+00 3.07673305 0.59295264 737.50 -9.01719586e+00 2.66066567e-01 9.02112036e+00 3.11209464 0.57180427 737.75 -8.93386273e+00 -7.12882561e-01 8.96226003e+00 -3.06196581 0.59856242 738.00 -8.73592921e+00 -1.73642058e+00 8.90682972e+00 -2.94538227 0.61323844 738.25 -9.36721162e+00 -2.03334471e+00 9.58536094e+00 -2.92783838 0.70479466 738.50 -7.51280746e+00 -3.31701001e+00 8.21248022e+00 -2.72581802 0.63493855 738.75 -7.31081134e+00 -4.40760915e+00 8.53668441e+00 -2.59905145 0.67158789 739.00 -7.06303212e+00 -3.61835063e+00 7.93592364e+00 -2.66815810 0.65315934 739.25 -5.89518220e+00 -3.26554764e+00 6.73921172e+00 -2.63573336 0.66326405 739.50 -5.27987869e+00 -3.42334238e+00 6.29256641e+00 -2.56636050 0.75832124 739.75 -4.68698455e+00 -3.20519659e+00 5.67812552e+00 -2.54178773 0.76590875 740.00 -3.45927375e+00 -2.73611784e+00 4.41054596e+00 -2.47239348 0.68500587 740.25 -2.87139929e+00 -2.87466686e+00 4.06308299e+00 -2.35562583 0.70468839 740.50 -2.34306966e+00 -2.88519569e+00 3.71676333e+00 -2.25287236 0.69023988 740.75 -1.70776304e+00 -2.69822337e+00 3.19325288e+00 -2.13507159 0.69311580 741.00 -1.27005236e+00 -2.40983920e+00 2.72403340e+00 -2.05583169 0.70742554 741.25 -1.09099287e+00 -2.37125658e+00 2.61019601e+00 -2.00200985 0.73006847 741.50 -5.72496876e-01 -1.86644542e+00 1.95227334e+00 -1.86841695 0.58249365 741.75 -3.75331115e-01 -1.73617763e+00 1.77628438e+00 -1.78370241 0.52547488 742.00 -2.73049866e-02 -1.78949109e+00 1.78969939e+00 -1.58605366 0.53421138 742.25 1.26467018e-01 -1.84744675e+00 1.85177034e+00 -1.50244793 0.52502697 742.50 2.41065108e-01 -1.29876761e+00 1.32095030e+00 -1.38727418 0.22041174 742.75 4.14341467e-01 -4.76800693e-01 6.31678519e-01 -0.85537269 0.03143693 743.00 8.61270979e-01 -1.52446756e+00 1.75093948e+00 -1.05653624 0.24288533 743.25 7.04088905e-01 -2.15461013e+00 2.26673466e+00 -1.25495306 0.43301451 743.50 7.41834415e-01 -2.20738721e+00 2.32870707e+00 -1.24658570 0.51435274 743.75 9.27432519e-01 -2.00082470e+00 2.20531870e+00 -1.13675200 0.59072998 744.00 1.21825225e+00 -2.32204246e+00 2.62221657e+00 -1.08762621 0.78136213 744.25 1.17275412e+00 -2.33942940e+00 2.61692226e+00 -1.10610989 0.82784454 744.50 6.65146351e-01 -2.07443371e+00 2.17846159e+00 -1.26051297 0.76911324 744.75 5.08744634e-01 -1.88680086e+00 1.95418489e+00 -1.30742616 0.80108609 745.00 3.74415178e-01 -1.86558735e+00 1.90278819e+00 -1.37273201 0.78742544 745.25 2.06698227e-01 -1.72576512e+00 1.73809937e+00 -1.45159223 0.74123413 745.50 -7.95813023e-02 -1.35947669e+00 1.36180397e+00 -1.62926779 0.71211642 745.75 -1.95948048e-01 -1.14733009e+00 1.16394243e+00 -1.73995042 0.66086894 746.00 -3.91922245e-01 -7.13278139e-01 8.13860399e-01 -2.07322964 0.48229153 746.25 -3.84353597e-01 -4.74649099e-01 6.10753187e-01 -2.25146244 0.34697171 746.50 -5.28804394e-01 1.21439800e-01 5.42569546e-01 2.91585694 0.21623847 746.75 -5.01735608e-01 6.05092441e-01 7.86050559e-01 2.26308340 0.27620490 747.00 2.78732683e-01 1.58445454e+00 1.60878466e+00 1.39666093 0.61905637 747.25 5.23942521e-01 1.76241503e+00 1.83864692e+00 1.28183067 0.68333786 747.50 9.59176243e-01 1.76346055e+00 2.00743921e+00 1.07263533 0.68261774 747.75 1.30700730e+00 1.45025872e+00 1.95231105e+00 0.83730565 0.66276209 748.00 1.42240041e+00 1.47705299e+00 2.05058735e+00 0.80424520 0.74797306 748.25 1.15340932e+00 1.68619430e+00 2.04294011e+00 0.97086834 0.71138105 748.50 8.86361241e-01 1.86703609e+00 2.06675107e+00 1.12755817 0.67384020 748.75 1.09530265e+00 2.08368458e+00 2.35402407e+00 1.08683470 0.66076323 749.00 1.22964921e+00 2.55447730e+00 2.83502936e+00 1.12216334 0.66819599 749.25 1.58746213e+00 3.32360737e+00 3.68325969e+00 1.12520249 0.65617414 749.50 2.14701861e+00 3.85593084e+00 4.41337644e+00 1.06274019 0.70111644 749.75 3.27941734e+00 2.93039583e+00 4.39793108e+00 0.72925240 0.46269638 750.00 3.90042675e+00 1.71645024e+00 4.26140004e+00 0.41456325 0.32968194 750.25 4.85073633e+00 1.42607345e-01 4.85283214e+00 0.02939065 0.51339215 750.50 4.94887197e+00 4.18013334e-02 4.94904851e+00 0.00844644 0.62726302 750.75 5.05607674e+00 2.48695873e-01 5.06218941e+00 0.04914791 0.63550508 751.00 5.19536368e+00 -3.86086514e-01 5.20968968e+00 -0.07417732 0.61008220 751.25 4.64075476e+00 -2.85571875e-01 4.64953288e+00 -0.06145816 0.54576571 751.50 5.14586617e+00 -3.52239183e-01 5.15790763e+00 -0.06834429 0.53316460 751.75 6.08335166e+00 -6.30190226e-01 6.11590608e+00 -0.10322440 0.60810611 752.00 5.01870142e+00 -6.90557100e-01 5.06598787e+00 -0.13673813 0.49500769 752.25 4.95932155e+00 -1.79068374e+00 5.27270505e+00 -0.34650633 0.54575187 752.50 4.78623001e+00 -2.40989223e+00 5.35869184e+00 -0.46644792 0.51566061 752.75 3.94486796e+00 -1.88441761e+00 4.37184320e+00 -0.44563953 0.47189741 753.00 3.86713006e+00 -2.37285922e+00 4.53708671e+00 -0.55035732 0.54450491 753.25 2.78130213e+00 -1.43618318e+00 3.13021783e+00 -0.47665830 0.36091792 753.50 2.26027545e+00 -1.74367484e+00 2.85468861e+00 -0.65708430 0.42383307 753.75 1.10639396e+00 -9.46063206e-01 1.45572772e+00 -0.70743999 0.18420117 754.00 9.17344064e-01 -5.07898540e-01 1.04856142e+00 -0.50565037 0.10986022 754.25 7.90201518e-01 -3.74203537e-01 8.74326442e-01 -0.44226833 0.07795004 754.50 5.30084831e-01 -3.93586676e-01 6.60227537e-01 -0.63868221 0.06955832 754.75 6.25302053e-01 3.29287581e-01 7.06705716e-01 0.48470487 0.10254271 755.00 1.17698954e+00 7.62923295e-01 1.40262480e+00 0.57510801 0.35189260 755.25 2.13000877e+00 1.31922674e+00 2.50545336e+00 0.55452805 0.67431162 755.50 2.39443752e+00 1.59105190e+00 2.87485255e+00 0.58648609 0.67240664 755.75 3.24767117e+00 1.52929093e+00 3.58972127e+00 0.44008836 0.61855846 756.00 3.48557345e+00 1.37880039e+00 3.74837468e+00 0.37668459 0.54788351 756.25 3.39470120e+00 5.78738369e-02 3.39519449e+00 0.01704663 0.33906934 756.50 2.90699938e+00 -7.72163625e-01 3.00780352e+00 -0.25962703 0.26076268 756.75 2.30415668e+00 -2.26480837e+00 3.23086598e+00 -0.77678629 0.21473744 757.00 1.91384629e+00 -2.52752972e+00 3.17036498e+00 -0.92270292 0.24279443 757.25 2.52517073e-01 -2.94311430e+00 2.95392732e+00 -1.48520666 0.27514895 757.50 -5.76265357e-01 -3.45589270e+00 3.50360901e+00 -1.73602475 0.38441729 757.75 -8.63341125e-01 -4.55559463e+00 4.63667988e+00 -1.75808750 0.62800663 758.00 -1.26656469e+00 -4.24822015e+00 4.43300807e+00 -1.86054590 0.75251644 758.25 -1.51361453e+00 -3.80500653e+00 4.09500960e+00 -1.94940084 0.83638793 758.50 -1.49747658e+00 -3.31246888e+00 3.63522849e+00 -1.99537253 0.84974708 758.75 -1.48558964e+00 -2.93093340e+00 3.28593170e+00 -2.03992141 0.90182392 759.00 -1.48208377e+00 -2.59260230e+00 2.98632868e+00 -2.09011594 0.88968572 759.25 -1.52841599e+00 -2.26167719e+00 2.72969580e+00 -2.16508766 0.90760047 759.50 -1.40284603e+00 -2.05583003e+00 2.48885799e+00 -2.16959491 0.89150385 759.75 -1.18193307e+00 -1.81687286e+00 2.16748536e+00 -2.14754511 0.85765316 760.00 -1.06256814e+00 -1.32680779e+00 1.69984410e+00 -2.24605265 0.79412783 760.25 -8.93144611e-01 -1.06400406e+00 1.38917671e+00 -2.26911507 0.82705569 760.50 -6.25317817e-01 -9.68305217e-01 1.15266533e+00 -2.14420335 0.75763008 760.75 -4.85552758e-01 -8.43091083e-01 9.72915235e-01 -2.09332151 0.71275483 761.00 -2.38735652e-01 -7.69179215e-01 8.05376543e-01 -1.87174604 0.67962820 761.25 -5.30059963e-02 -7.73908115e-01 7.75721217e-01 -1.63918086 0.72966693 761.50 7.28232308e-02 -7.75710873e-01 7.79121673e-01 -1.47719133 0.64537243 761.75 1.59967536e-01 -7.72212125e-01 7.88607113e-01 -1.36653060 0.60986468 762.00 2.42994844e-01 -8.90680157e-01 9.23232168e-01 -1.30445851 0.71037524 762.25 3.04171606e-01 -8.89686189e-01 9.40245649e-01 -1.24136787 0.72109399 762.50 5.26699082e-01 -8.57574281e-01 1.00640229e+00 -1.02002054 0.74679609 762.75 6.78659492e-01 -8.74582774e-01 1.10701117e+00 -0.91087375 0.78496838 763.00 8.19278619e-01 -1.00851411e+00 1.29935298e+00 -0.88856285 0.84994385 763.25 8.28431933e-01 -1.10478059e+00 1.38088364e+00 -0.92738415 0.85278368 763.50 8.30606952e-01 -1.47375721e+00 1.69170572e+00 -1.05757300 0.84590544 763.75 8.12588860e-01 -1.60705741e+00 1.80081486e+00 -1.10264871 0.89398426 764.00 5.30514932e-01 -1.80174845e+00 1.87822884e+00 -1.28444408 0.89153085 764.25 3.88970161e-01 -2.05531652e+00 2.09179917e+00 -1.38375764 0.92020371 764.50 9.42957067e-02 -2.34098971e+00 2.34288807e+00 -1.53053782 0.92169255 764.75 -9.86876960e-02 -2.29164159e+00 2.29376556e+00 -1.61383393 0.92879578 765.00 -3.46209004e-01 -2.14674153e+00 2.17447922e+00 -1.73069146 0.95606170 765.25 -5.29657093e-01 -2.03989515e+00 2.10753621e+00 -1.82483575 0.93437022 765.50 -9.12132447e-01 -1.69084814e+00 1.92118532e+00 -2.06550569 0.92422293 765.75 -1.03090000e+00 -1.46846777e+00 1.79419966e+00 -2.18287956 0.91466637 766.00 -1.04474757e+00 -1.16309398e+00 1.56342096e+00 -2.30264297 0.92751346 766.25 -1.04652448e+00 -1.00756101e+00 1.45271906e+00 -2.37516098 0.90831231 766.50 -9.51835825e-01 -7.06117425e-01 1.18515537e+00 -2.50332932 0.86421160 766.75 -8.40258675e-01 -6.40131417e-01 1.05631571e+00 -2.49056538 0.84309692 767.00 -6.66899933e-01 -6.85779543e-01 9.56581989e-01 -2.34223820 0.83553883 767.25 -5.73361312e-01 -6.46926799e-01 8.64440557e-01 -2.29598202 0.83532472 767.50 -4.38153000e-01 -5.63523458e-01 7.13818422e-01 -2.23168134 0.85203479 767.75 -4.36193344e-01 -5.87723998e-01 7.31904455e-01 -2.20926981 0.83322039 768.00 -3.62861930e-01 -7.41792513e-01 8.25787451e-01 -2.02574168 0.80627331 768.25 -3.72988070e-01 -8.48731709e-01 9.27073684e-01 -1.98485508 0.83414871 768.50 -4.79799246e-01 -9.29026372e-01 1.04560859e+00 -2.04752020 0.90211577 768.75 -5.46623994e-01 -9.31606808e-01 1.08013380e+00 -2.10141916 0.90210887 769.00 -7.45389946e-01 -9.20308107e-01 1.18430283e+00 -2.25156604 0.90445592 769.25 -9.15472519e-01 -8.41237411e-01 1.24329012e+00 -2.39842740 0.88451365 769.50 -1.14213773e+00 -7.16924810e-01 1.34850279e+00 -2.58105101 0.86617229 769.75 -1.25805671e+00 -4.84896058e-01 1.34826959e+00 -2.77370712 0.81245774 770.00 -1.20868810e+00 -1.54238337e-01 1.21848938e+00 -3.01467056 0.67827481 770.25 -9.61664018e-01 8.65071563e-02 9.65547084e-01 3.05187843 0.54321884 770.50 -6.38886178e-01 4.66894697e-01 7.91306645e-01 2.51049660 0.45983885 770.75 -4.43685273e-01 4.20042949e-01 6.10976841e-01 2.38356007 0.43929275 771.00 -3.34192178e-01 3.58762315e-01 4.90300735e-01 2.32075227 0.46453486 771.25 -3.13325488e-01 2.59679705e-01 4.06947676e-01 2.44954420 0.34614161 771.50 -2.71510285e-01 1.92112021e-01 3.32603162e-01 2.52580545 0.36205539 771.75 -3.33377473e-01 6.44236801e-02 3.39545211e-01 2.95070021 0.47062475 772.00 -3.40008119e-01 3.48425667e-02 3.41788715e-01 3.03947343 0.62029446 772.25 -3.78550362e-01 3.97393485e-02 3.80630520e-01 3.03699805 0.69922376 772.50 -3.85337230e-01 6.69041133e-02 3.91102213e-01 2.96968160 0.72552240 772.75 -3.83131828e-01 1.46651898e-01 4.10239902e-01 2.77602619 0.70564729 773.00 -3.77817313e-01 2.41740013e-01 4.48535569e-01 2.57239789 0.75395711 773.25 -2.52977648e-01 3.24403816e-01 4.11382457e-01 2.23311274 0.69456592 773.50 -2.00456733e-01 3.56526093e-01 4.09015595e-01 2.08299572 0.74013336 773.75 -8.94475938e-02 3.28739878e-01 3.40691620e-01 1.83645728 0.60951945 774.00 -1.52466397e-02 3.09926734e-01 3.10301532e-01 1.61995103 0.57175487 774.25 1.32291867e-01 2.42413295e-01 2.76161807e-01 1.07123842 0.40874928 774.50 2.14227965e-01 2.12123525e-01 3.01479702e-01 0.78046228 0.47787962 774.75 3.20474118e-01 1.37248151e-01 3.48626900e-01 0.40463368 0.50972921 775.00 3.01756326e-01 -1.46143952e-02 3.02110014e-01 -0.04839330 0.42033566 775.25 1.67692171e-01 -1.62230393e-01 2.33322448e-01 -0.76884495 0.41480343 775.50 1.49733160e-01 -1.92775884e-01 2.44095392e-01 -0.91041168 0.43636950 775.75 1.44742756e-02 -3.15948298e-01 3.16279673e-01 -1.52501617 0.54312015 776.00 -8.40745376e-02 -3.99130199e-01 4.07889009e-01 -1.77840561 0.64790532 776.25 -2.85843796e-01 -3.62878545e-01 4.61938864e-01 -2.23799957 0.75756628 776.50 -3.56497137e-01 -3.07370154e-01 4.70708636e-01 -2.43006106 0.78125513 776.75 -3.75147719e-01 -1.36463740e-01 3.99196898e-01 -2.79271244 0.77741206 777.00 -3.64899296e-01 -7.62678620e-02 3.72784499e-01 -2.93554815 0.78667765 777.25 -3.69416766e-01 2.13175773e-02 3.70031332e-01 3.08395054 0.78538133 777.50 -3.64951585e-01 6.11637951e-02 3.70041442e-01 2.97554158 0.74359782 777.75 -3.08342368e-01 4.96136019e-02 3.12308382e-01 2.98205582 0.64009039 778.00 -2.81770615e-01 1.01949154e-01 2.99646975e-01 2.79443024 0.70163439 778.25 -2.32445513e-01 1.55852026e-01 2.79858484e-01 2.55094888 0.74888872 778.50 -1.92734753e-01 1.48461542e-01 2.43284842e-01 2.48523226 0.66580891 778.75 -1.37740964e-01 1.44268346e-01 1.99464104e-01 2.33305264 0.60005647 779.00 -1.22908052e-01 1.32606196e-01 1.80805952e-01 2.31825731 0.52164826 779.25 -1.00011868e-01 1.08376926e-01 1.47471800e-01 2.31607444 0.52558402 779.50 -1.25130312e-01 1.01810844e-01 1.61316593e-01 2.45859068 0.45512363 779.75 -1.43486659e-01 8.50119272e-02 1.66779643e-01 2.60672632 0.51812382 780.00 -1.12132637e-01 8.56941355e-02 1.41128357e-01 2.48905195 0.45098200 780.25 -8.29471920e-02 8.27038835e-02 1.17133125e-01 2.35766329 0.34397977 780.50 -6.10843966e-02 6.77050403e-02 9.11881351e-02 2.30483297 0.24367559 780.75 -4.10136431e-02 4.33361493e-02 5.96669151e-02 2.32866722 0.13797955 781.00 -1.01082193e-01 4.70677012e-03 1.01191717e-01 3.09506247 0.24995261 781.25 -1.69443933e-01 -3.37068631e-02 1.72763998e-01 -2.94522966 0.52678198 781.50 -2.33339045e-01 -5.60943794e-02 2.39986853e-01 -2.90567082 0.63768426 781.75 -2.63230583e-01 -1.45687924e-02 2.63633437e-01 -3.08630294 0.71482211 782.00 -2.52734526e-01 8.32253045e-02 2.66084934e-01 2.82347711 0.73699201 782.25 -2.46189754e-01 1.47252837e-01 2.86867204e-01 2.60255121 0.73445793 782.50 -1.84928921e-01 2.02457755e-01 2.74204027e-01 2.31097640 0.60410601 782.75 -1.10244316e-01 2.55628196e-01 2.78387471e-01 1.97796421 0.62134663 783.00 -4.47339887e-02 2.35350507e-01 2.39564169e-01 1.75862960 0.50234089 783.25 8.72703334e-02 1.80851911e-01 2.00807183e-01 1.12120482 0.28070333 783.50 1.40056961e-01 6.35351619e-02 1.53794242e-01 0.42587518 0.22471960 783.75 1.59940699e-01 2.55895915e-02 1.61974858e-01 0.15864965 0.26357437 784.00 2.27113598e-01 -1.05410532e-01 2.50383639e-01 -0.43454319 0.29875616 784.25 1.66255616e-01 -2.47891104e-01 2.98481037e-01 -0.98002038 0.36908897 784.50 -1.86581336e-02 -3.85259261e-01 3.85710803e-01 -1.61918859 0.57302269 784.75 -9.54252404e-02 -4.13429233e-01 4.24299077e-01 -1.79763765 0.64394830 785.00 -2.74694597e-01 -3.97033881e-01 4.82797084e-01 -2.17604295 0.70516519 785.25 -3.66926717e-01 -4.26192951e-01 5.62383896e-01 -2.28160765 0.84076227 785.50 -4.86349114e-01 -3.97852662e-01 6.28348790e-01 -2.45594855 0.87558835 785.75 -5.84584119e-01 -3.30083177e-01 6.71337096e-01 -2.62757437 0.87077732 786.00 -7.08125031e-01 -1.93573370e-01 7.34106061e-01 -2.87475137 0.91440224 786.25 -6.85547717e-01 -8.46834226e-02 6.90758246e-01 -3.01868859 0.89200303 786.50 -6.39535845e-01 1.18433042e-01 6.50409474e-01 2.95848111 0.91549719 786.75 -6.31469048e-01 1.83197418e-01 6.57506238e-01 2.85923095 0.94279505 787.00 -5.18768986e-01 2.59639944e-01 5.80115645e-01 2.67755119 0.92497401 787.25 -4.27015159e-01 2.86417331e-01 5.14175878e-01 2.55077344 0.90752401 787.50 -2.99841397e-01 2.87334353e-01 4.15290133e-01 2.37749161 0.89457742 787.75 -2.51323752e-01 2.55599253e-01 3.58461443e-01 2.34776047 0.86102836 788.00 -1.94565009e-01 1.49685016e-01 2.45481459e-01 2.48583366 0.72870864 788.25 -1.86752254e-01 1.07911823e-01 2.15688122e-01 2.61763107 0.73532229 788.50 -1.85922358e-01 4.00776982e-02 1.90192916e-01 2.92927989 0.75241123 788.75 -2.15293600e-01 -8.65115005e-03 2.15467344e-01 -3.10143123 0.76229739 789.00 -2.67164762e-01 -4.87421093e-02 2.71574674e-01 -2.96113523 0.89565512 789.25 -2.96913362e-01 -7.58241398e-02 3.06442237e-01 -2.89156195 0.90988885 789.50 -3.33202729e-01 -1.08900418e-01 3.50547229e-01 -2.82570710 0.93663417 789.75 -3.72506250e-01 -1.30333052e-01 3.94648718e-01 -2.80502339 0.92709528 790.00 -4.29907633e-01 -1.56062885e-01 4.57357844e-01 -2.79337063 0.94922300 790.25 -4.61146372e-01 -1.53758917e-01 4.86104702e-01 -2.81975728 0.95720244 790.50 -4.99115025e-01 -1.45650942e-01 5.19932693e-01 -2.85765872 0.95241064 790.75 -5.68316937e-01 -1.16085036e-01 5.80051615e-01 -2.94010327 0.94874522 791.00 -6.38582054e-01 -8.54054887e-02 6.44267908e-01 -3.00863923 0.96668972 791.25 -6.88155947e-01 -6.58135217e-02 6.91295904e-01 -3.04624514 0.94821962 791.50 -7.80719852e-01 -4.05411465e-02 7.81771752e-01 -3.08971135 0.95280975 791.75 -8.39729762e-01 1.39639617e-02 8.39845858e-01 3.12496507 0.93453049 792.00 -8.98128532e-01 1.28668612e-01 9.07298447e-01 2.99929785 0.93715266 792.25 -9.26912157e-01 2.65485068e-01 9.64182799e-01 2.86264177 0.93140067 792.50 -9.59852965e-01 3.62905679e-01 1.02616677e+00 2.78012037 0.94549837 792.75 -9.16625223e-01 4.67394425e-01 1.02891173e+00 2.67005019 0.93963668 793.00 -8.82667917e-01 5.89795601e-01 1.06158443e+00 2.55253169 0.93427647 793.25 -6.45489814e-01 7.18962903e-01 9.66211548e-01 2.30239842 0.92816249 793.50 -5.44375880e-01 8.07048539e-01 9.73484691e-01 2.16422085 0.95143708 793.75 -4.49278545e-01 7.65768118e-01 8.87835583e-01 2.10138133 0.92595394 794.00 -3.41620352e-01 7.28987453e-01 8.05063458e-01 2.00902883 0.92828894 794.25 -2.89254028e-01 6.85121771e-01 7.43679860e-01 1.97028753 0.93555050 794.50 -2.76225325e-01 6.40218011e-01 6.97265754e-01 1.97812177 0.94103403 794.75 -2.28891007e-01 6.13152225e-01 6.54482043e-01 1.92807759 0.93284999 795.00 -2.02034992e-01 5.97072256e-01 6.30328023e-01 1.89707850 0.94015993 795.25 -1.62473485e-01 5.66611274e-01 5.89445476e-01 1.85004952 0.91319968 795.50 -1.33885066e-01 5.52316737e-01 5.68312404e-01 1.80861532 0.88054042 795.75 -9.29509906e-02 4.70286223e-01 4.79383998e-01 1.76592904 0.83690148 796.00 -8.71226767e-02 4.55373059e-01 4.63632379e-01 1.75983346 0.83979229 796.25 -7.28759508e-02 4.03256681e-01 4.09788793e-01 1.74958515 0.75742629 796.50 -5.00198996e-02 3.64134694e-01 3.67554167e-01 1.70730844 0.73027656 796.75 -6.42904118e-02 3.02996764e-01 3.09742306e-01 1.77987729 0.54293685 797.00 -1.25663979e-02 2.61579037e-01 2.61880711e-01 1.61879996 0.41203023 797.25 5.31748898e-02 2.20040588e-01 2.26374533e-01 1.33368286 0.31491387 797.50 2.27715808e-02 1.72545912e-01 1.74042054e-01 1.43958058 0.21896883 797.75 -5.55619675e-02 5.68076743e-02 7.94622180e-02 2.34510915 0.05981427 798.00 -4.27107052e-02 -2.15011662e-02 4.78174078e-02 -2.67521759 0.01685697 798.25 -1.27101211e-01 -1.34130401e-01 1.84785504e-01 -2.32929310 0.19648570 798.50 -1.66138815e-01 -1.31820871e-01 2.12082172e-01 -2.47086568 0.19767518 798.75 -2.58785780e-01 -1.63431798e-01 3.06071940e-01 -2.57830914 0.25294798 799.00 -2.82431462e-01 -2.21254182e-01 3.58777011e-01 -2.47706170 0.28162669 799.25 -2.55582939e-01 -3.72570761e-01 4.51809263e-01 -2.17206329 0.39500342 799.50 -3.40873579e-01 -4.04786564e-01 5.29194633e-01 -2.27069018 0.42944632 799.75 -6.05004704e-01 -6.68083633e-01 9.01313726e-01 -2.30668702 0.59517413 800.00 -8.23306641e-01 -7.05142679e-01 1.08400186e+00 -2.43335072 0.47602168 800.25 -1.20196041e+00 -4.13937484e-01 1.27124076e+00 -2.80992853 0.37132311 800.50 -1.33783124e+00 7.51773109e-02 1.33994181e+00 3.08545827 0.40865715 800.75 -1.49885366e+00 3.41329850e-01 1.53722749e+00 2.91768388 0.57823645 801.00 -1.44354270e+00 6.54794584e-01 1.58510929e+00 2.71574692 0.66353540 801.25 -1.35199245e+00 8.94017950e-01 1.62084906e+00 2.55734277 0.69825094 801.50 -1.18545154e+00 1.09803432e+00 1.61585109e+00 2.39445816 0.70064741 801.75 -9.34954422e-01 1.12094737e+00 1.45967900e+00 2.26597228 0.69226884 802.00 -9.57551107e-01 1.26484532e+00 1.58642296e+00 2.21879417 0.74278085 802.25 -8.41013046e-01 1.26267675e+00 1.51712080e+00 2.15837583 0.76906785 802.50 -8.01520320e-01 1.14140876e+00 1.39472175e+00 2.18301082 0.79807754 802.75 -8.68906031e-01 1.18774430e+00 1.47164337e+00 2.20239091 0.81551154 803.00 -7.88247431e-01 1.14578255e+00 1.39073781e+00 2.17339293 0.77605140 803.25 -6.83696702e-01 1.14922242e+00 1.33721852e+00 2.10747299 0.80340303 803.50 -8.37699420e-01 1.21631103e+00 1.47687266e+00 2.17391258 0.77627488 803.75 -9.90442005e-01 1.41890708e+00 1.73039668e+00 2.18020001 0.83796962 804.00 -8.72302628e-01 1.69365225e+00 1.90509050e+00 2.04640527 0.86392469 804.25 -6.55108190e-01 1.77671023e+00 1.89363829e+00 1.92404971 0.84757434 804.50 -5.62936840e-01 1.84466838e+00 1.92865220e+00 1.86698916 0.84183376 804.75 -5.98011583e-01 1.85174136e+00 1.94590953e+00 1.88316890 0.87062876 805.00 -3.89951476e-01 1.94768167e+00 1.98633483e+00 1.76839683 0.88403236 805.25 -2.19284892e-01 2.12766190e+00 2.13893222e+00 1.67349750 0.86270213 805.50 1.01990633e-02 2.14946310e+00 2.14948729e+00 1.56605143 0.89147654 805.75 1.94635617e-01 2.16576775e+00 2.17449603e+00 1.48116799 0.87988312 806.00 5.95408773e-01 2.29247674e+00 2.36853567e+00 1.31668781 0.88367056 806.25 7.09912758e-01 2.33239934e+00 2.43804488e+00 1.27533505 0.88884690 806.50 1.19625773e+00 2.26851471e+00 2.56460359e+00 1.08552388 0.89200644 806.75 1.51439930e+00 2.20790167e+00 2.67735598e+00 0.96959640 0.88909754 807.00 2.01500449e+00 2.02957646e+00 2.85996917e+00 0.78900099 0.88340599 807.25 2.36229841e+00 1.98030356e+00 3.08254051e+00 0.69765949 0.88561279 807.50 2.67363024e+00 1.34059951e+00 2.99090382e+00 0.46477933 0.86527575 807.75 2.62888206e+00 9.69188188e-01 2.80184700e+00 0.35320898 0.85370914 808.00 2.70692288e+00 2.61062630e-01 2.71948252e+00 0.09614523 0.84412717 808.25 2.73132416e+00 5.07002457e-02 2.73179468e+00 0.01856038 0.81451239 808.50 2.68879875e+00 -3.59775634e-01 2.71276192e+00 -0.13301527 0.71574326 808.75 2.76030437e+00 -8.33850646e-01 2.88350258e+00 -0.29336990 0.71719941 809.00 2.52040215e+00 -1.29591968e+00 2.83404919e+00 -0.47492066 0.71263406 809.25 2.26372049e+00 -1.59536530e+00 2.76940804e+00 -0.61390922 0.67898246 809.50 1.64843624e+00 -2.42641615e+00 2.93340031e+00 -0.97405006 0.64186213 809.75 1.56601810e+00 -2.45982261e+00 2.91601439e+00 -1.00387140 0.67025199 810.00 9.08129371e-01 -2.67945116e+00 2.82916198e+00 -1.24402295 0.70184298 810.25 2.64981158e-01 -2.74893700e+00 2.76167877e+00 -1.47469919 0.65872386 810.50 -3.22589194e-01 -2.44104490e+00 2.46226806e+00 -1.70218707 0.64939873 810.75 -8.32530439e-01 -2.31749700e+00 2.46249859e+00 -1.91567619 0.67295314 811.00 -1.50869027e+00 -2.03595515e+00 2.53402046e+00 -2.20852757 0.59965561 811.25 -1.44108125e+00 -1.67942188e+00 2.21295572e+00 -2.27996359 0.48369799 811.50 -2.09360595e+00 -1.36622337e+00 2.49995043e+00 -2.56341323 0.59173062 811.75 -2.01874111e+00 -1.07957027e+00 2.28927666e+00 -2.65051437 0.63837174 812.00 -2.15139861e+00 -3.73155250e-01 2.18352028e+00 -2.96985351 0.70070018 812.25 -2.33305606e+00 -5.26404990e-02 2.33364984e+00 -3.11903359 0.78733705 812.50 -2.37176496e+00 -5.62563827e-02 2.37243204e+00 -3.11787789 0.73069870 812.75 -2.31593531e+00 3.85813974e-01 2.34785195e+00 2.97651760 0.72824067 813.00 -2.16693298e+00 5.35849977e-01 2.23220379e+00 2.89917093 0.75164974 813.25 -2.08570699e+00 5.38402863e-01 2.15407783e+00 2.88896830 0.74852623 813.50 -1.87556972e+00 4.57027527e-01 1.93044967e+00 2.90257670 0.67018638 813.75 -1.78435514e+00 3.65578720e-01 1.82142007e+00 2.93950920 0.68324926 814.00 -1.79108167e+00 4.51403466e-01 1.84708923e+00 2.89470581 0.71491359 814.25 -1.77416791e+00 6.51976315e-01 1.89017060e+00 2.78942858 0.75534028 814.50 -1.52440918e+00 8.58746740e-01 1.74964834e+00 2.62857226 0.68392209 814.75 -1.74247864e+00 9.16349120e-01 1.96873755e+00 2.65744955 0.74834368 815.00 -1.86982570e+00 8.85739970e-01 2.06900542e+00 2.69920399 0.77420401 815.25 -1.86489188e+00 1.08342316e+00 2.15676320e+00 2.61529259 0.75406353 815.50 -1.86594693e+00 1.15719375e+00 2.19564463e+00 2.58647822 0.78232082 815.75 -1.52410802e+00 1.33032227e+00 2.02303301e+00 2.42397994 0.64661407 816.00 -1.35293653e+00 1.27511224e+00 1.85912573e+00 2.38579879 0.59054529 816.25 -1.35781035e+00 1.81295155e+00 2.26504796e+00 2.21362520 0.82924658 816.50 -1.37483282e+00 1.89123239e+00 2.33814568e+00 2.19938200 0.86193795 816.75 -1.20654163e+00 2.01618383e+00 2.34962549e+00 2.11005943 0.72429371 817.00 -8.05658197e-01 2.10492222e+00 2.25383732e+00 1.93634382 0.66632722 817.25 -2.49002335e-01 1.83778957e+00 1.85458154e+00 1.70546637 0.55664834 817.50 8.36406135e-03 1.64144766e+00 1.64146897e+00 1.56570083 0.53692890 817.75 -1.87528320e-01 1.36725534e+00 1.38005581e+00 1.70710261 0.59393554 818.00 -1.76730929e-01 1.34335702e+00 1.35493243e+00 1.70160428 0.55251964 818.25 -1.60509329e-01 1.14705394e+00 1.15822968e+00 1.70982538 0.45059495 818.50 -2.48862689e-01 9.80460423e-01 1.01155093e+00 1.81936917 0.45662976 818.75 -4.98812981e-02 1.18508516e+00 1.18613447e+00 1.61286239 0.59632903 819.00 6.13730561e-02 1.11328111e+00 1.11497152e+00 1.51572399 0.62294737 819.25 1.21628166e-01 9.97375529e-01 1.00476433e+00 1.44944729 0.61074690 819.50 6.45937549e-02 9.48613992e-01 9.50810633e-01 1.50280850 0.64756618 819.75 -1.70082302e-01 6.86824689e-01 7.07570592e-01 1.81354852 0.58551973 820.00 -2.29046949e-01 6.20202785e-01 6.61145974e-01 1.92456900 0.54478414 820.25 -4.35412851e-01 4.67536460e-01 6.38885508e-01 2.32063317 0.61141225 820.50 -5.56704093e-01 4.67077257e-01 7.26691552e-01 2.44351676 0.66838341 820.75 -7.41815320e-01 5.25299430e-01 9.08971650e-01 2.52543315 0.75743347 821.00 -9.54276764e-01 6.24967136e-01 1.14071384e+00 2.56177223 0.81384156 821.25 -1.19167639e+00 8.06294648e-01 1.43882024e+00 2.54674093 0.90698475 821.50 -1.31869217e+00 9.79071728e-01 1.64241605e+00 2.50293682 0.92993036 821.75 -1.29738170e+00 1.25164423e+00 1.80272365e+00 2.37413568 0.95301255 822.00 -1.20906300e+00 1.43223989e+00 1.87433840e+00 2.27189971 0.95218310 822.25 -1.08205044e+00 1.63011753e+00 1.95655726e+00 2.15680250 0.95411057 822.50 -1.03146971e+00 1.76393606e+00 2.04337960e+00 2.09993054 0.95871862 822.75 -9.48568789e-01 1.92447395e+00 2.14554952e+00 2.02874597 0.96687174 823.00 -7.76639587e-01 1.91047780e+00 2.06230320e+00 1.95690720 0.96013004 823.25 -6.57546605e-01 1.87809701e+00 1.98987837e+00 1.90757201 0.96551308 823.50 -5.92019804e-01 1.85766991e+00 1.94972432e+00 1.87931001 0.95761126 823.75 -6.01628529e-01 1.92549813e+00 2.01730016e+00 1.87363878 0.95270677 824.00 -6.76799251e-01 2.03629133e+00 2.14581910e+00 1.89167835 0.94037371 824.25 -6.14586675e-01 2.08886785e+00 2.17740343e+00 1.85694196 0.96432214 824.50 -5.10624175e-01 2.20993290e+00 2.26815794e+00 1.79786997 0.95244344 824.75 -4.63717838e-01 2.36368193e+00 2.40873961e+00 1.76452049 0.94717319 825.00 -2.52417785e-01 2.50634931e+00 2.51902791e+00 1.67116922 0.95534254 825.25 -1.33096269e-01 2.60195313e+00 2.60535500e+00 1.62190423 0.96053039 825.50 1.66406205e-01 2.73082016e+00 2.73588556e+00 1.50993524 0.93373740 825.75 3.34594486e-01 2.82095667e+00 2.84073054e+00 1.45273761 0.93944010 826.00 7.29210964e-01 2.84613845e+00 2.93806955e+00 1.31998095 0.93112443 826.25 9.22010870e-01 2.84536930e+00 2.99102499e+00 1.25743379 0.92461389 826.50 9.44834152e-01 2.42964978e+00 2.60689655e+00 1.19991564 0.83159200 826.75 1.07183448e+00 2.32933351e+00 2.56410291e+00 1.13953674 0.85614826 827.00 1.35986629e+00 2.22130710e+00 2.60450409e+00 1.02146037 0.88581678 827.25 1.53109956e+00 2.08754980e+00 2.58884724e+00 0.93797594 0.88866985 827.50 1.85567839e+00 1.72088383e+00 2.53080688e+00 0.74772769 0.87502206 827.75 1.89774621e+00 1.70379460e+00 2.55036403e+00 0.73159773 0.87880416 828.00 2.17918548e+00 1.51221440e+00 2.65247842e+00 0.60664430 0.88000933 828.25 2.31533321e+00 1.46564533e+00 2.74023431e+00 0.56434360 0.91225338 828.50 2.35596086e+00 1.25783321e+00 2.67071076e+00 0.49039368 0.86100774 828.75 2.45284082e+00 1.02562088e+00 2.65863241e+00 0.39604238 0.84944156 829.00 2.61537226e+00 5.45037208e-01 2.67156089e+00 0.20545695 0.88890067 829.25 2.61384249e+00 2.46840490e-01 2.62547191e+00 0.09415663 0.85036080 829.50 2.54613704e+00 -4.99140394e-01 2.59460112e+00 -0.19358335 0.84106033 829.75 2.22006715e+00 -7.88114345e-01 2.35580610e+00 -0.34111840 0.84562967 830.00 1.47478873e+00 -1.00228480e+00 1.78313674e+00 -0.59691161 0.85218126 830.25 1.19385099e+00 -1.08321629e+00 1.61202907e+00 -0.73684986 0.83334619 830.50 7.84407961e-01 -9.80912573e-01 1.25597983e+00 -0.89625564 0.77719397 830.75 5.85886559e-01 -8.34942181e-01 1.01999584e+00 -0.95892421 0.70973976 831.00 1.85064567e-01 -6.60793458e-01 6.86219271e-01 -1.29772813 0.67796673 831.25 4.58871489e-02 -5.55452665e-01 5.57344861e-01 -1.48837133 0.59073031 831.50 -5.23569298e-03 -4.09790979e-01 4.09824424e-01 -1.58357213 0.45781559 831.75 3.47882585e-03 -2.47395922e-01 2.47420380e-01 -1.55673548 0.25084360 832.00 -2.35543248e-02 -1.48315248e-01 1.50173963e-01 -1.72829358 0.17773602 832.25 3.50005529e-02 -7.68035827e-02 8.44027785e-02 -1.14319989 0.06475142 832.50 8.17318930e-02 1.00923604e-02 8.23526446e-02 0.12285938 0.07142755 832.75 6.05024278e-02 2.75059742e-02 6.64614354e-02 0.42669421 0.03990424 833.00 9.39417453e-02 1.86886321e-02 9.57826523e-02 0.19637470 0.09698150 833.25 8.86847871e-02 1.34895232e-02 8.97048421e-02 0.15094935 0.07779786 833.50 6.34789597e-02 -4.26629565e-02 7.64833719e-02 -0.59174113 0.07842021 833.75 -4.26072205e-03 -7.31252445e-02 7.32492672e-02 -1.62899661 0.05367932 834.00 -9.29014334e-02 -5.34927815e-02 1.07201465e-01 -2.61915626 0.13498929 834.25 -1.79201708e-01 -6.47366218e-02 1.90536302e-01 -2.79493090 0.33447284 834.50 -2.03172840e-01 -1.06889915e-02 2.03453822e-01 -3.08903078 0.36121960 834.75 -3.31472336e-01 1.00199718e-01 3.46285854e-01 2.84803918 0.66219223 835.00 -3.94910478e-01 1.39097479e-01 4.18691287e-01 2.80293672 0.71170658 835.25 -4.73708145e-01 2.79234466e-01 5.49882982e-01 2.60895534 0.74824081 835.50 -4.85263234e-01 3.44495843e-01 5.95111579e-01 2.52424301 0.79528472 835.75 -5.36516323e-01 4.43845501e-01 6.96310702e-01 2.45044161 0.81421512 836.00 -5.78797997e-01 5.11932299e-01 7.72710683e-01 2.41742147 0.85214593 836.25 -5.29531602e-01 6.16678638e-01 8.12832246e-01 2.28030990 0.83110256 836.50 -4.90773188e-01 7.08282185e-01 8.61697149e-01 2.17674554 0.85319917 836.75 -4.72941215e-01 9.33859316e-01 1.04678872e+00 2.03958053 0.86516646 837.00 -4.63975601e-01 1.01318482e+00 1.11436835e+00 2.00023167 0.89133082 837.25 -2.58645828e-01 1.12182949e+00 1.15125978e+00 1.79739382 0.88263443 837.50 -1.69937991e-01 1.14367863e+00 1.15623515e+00 1.71830598 0.88724306 837.75 -1.23409079e-01 1.18469378e+00 1.19110418e+00 1.67459157 0.90826932 838.00 -6.80578006e-02 1.12601628e+00 1.12807116e+00 1.63116411 0.90581001 838.25 -6.09408722e-02 1.04142168e+00 1.04320319e+00 1.62924667 0.88179563 838.50 -7.48387750e-02 9.76314554e-01 9.79178712e-01 1.64730108 0.86507445 838.75 -5.92296796e-02 1.00783077e+00 1.00956972e+00 1.62949828 0.81870650 839.00 5.12774515e-03 1.08493648e+00 1.08494860e+00 1.56607005 0.84223844 839.25 -5.29825868e-02 1.22114152e+00 1.22229037e+00 1.61415689 0.87608700 839.50 -2.62133585e-04 1.27479962e+00 1.27479964e+00 1.57100195 0.87189623 839.75 1.46295192e-01 1.41237353e+00 1.41993003e+00 1.46758331 0.89627976 840.00 1.62614193e-01 1.43257056e+00 1.44177037e+00 1.45776796 0.88493723 840.25 2.82448198e-01 1.24813806e+00 1.27969746e+00 1.34824902 0.81955079 840.50 3.51683719e-01 1.12807230e+00 1.18162116e+00 1.26858908 0.81888828 840.75 2.70016443e-01 1.11955390e+00 1.15165525e+00 1.33413386 0.80507043 841.00 1.46535361e-01 1.07198632e+00 1.08195531e+00 1.43494314 0.75815838 841.25 -2.14782895e-02 1.24770552e+00 1.24789037e+00 1.58800886 0.84434831 841.50 -3.53535281e-02 1.30442829e+00 1.30490729e+00 1.59789239 0.86299559 841.75 -5.13222255e-02 1.42381960e+00 1.42474427e+00 1.60682618 0.82442702 842.00 -1.04138193e-01 1.78229937e+00 1.78533913e+00 1.62915910 0.84923154 842.25 -2.69778000e-02 2.12687671e+00 2.12704780e+00 1.58347988 0.90068941 842.50 1.27282932e-01 2.33782198e+00 2.34128438e+00 1.51640494 0.91308743 842.75 2.79491173e-01 2.53578484e+00 2.55114094e+00 1.46102062 0.91525387 843.00 6.49431764e-01 2.57977854e+00 2.66026670e+00 1.32418130 0.89299897 843.25 1.12759559e+00 2.72892193e+00 2.95270837e+00 1.17896111 0.89733308 843.50 1.51624496e+00 2.72914654e+00 3.12205695e+00 1.06368314 0.87012625 843.75 1.84493534e+00 2.80890912e+00 3.36061852e+00 0.98964473 0.87134775 844.00 2.43224438e+00 2.54399604e+00 3.51962052e+00 0.80785144 0.86779174 844.25 2.75639181e+00 2.07877007e+00 3.45238770e+00 0.64616042 0.91770820 844.50 2.94329592e+00 1.63942558e+00 3.36908104e+00 0.50820413 0.89092269 844.75 2.93953566e+00 1.27589054e+00 3.20449162e+00 0.40950677 0.89259532 845.00 2.97596726e+00 1.12295732e+00 3.18078831e+00 0.36082231 0.89902346 845.25 2.83792578e+00 9.42827377e-01 2.99044248e+00 0.32075192 0.90569566 845.50 2.87110357e+00 7.55979465e-01 2.96896289e+00 0.25746244 0.91417461 845.75 2.86665702e+00 7.27504767e-01 2.95753033e+00 0.24853462 0.90228512 846.00 2.57377903e+00 6.35123825e-01 2.65098486e+00 0.24193357 0.83315096 846.25 2.66382010e+00 3.77714197e-01 2.69046567e+00 0.14085520 0.81138782 846.50 2.62367829e+00 2.23835167e-01 2.63320906e+00 0.08510741 0.80784381 846.75 2.54603514e+00 2.31010357e-01 2.55649383e+00 0.09048561 0.76837269 847.00 2.07674207e+00 1.33770677e-01 2.08104595e+00 0.06432485 0.79219760 847.25 1.93684618e+00 1.27045294e-01 1.94100841e+00 0.06550007 0.77302822 847.50 2.30281802e+00 1.12954904e-01 2.30558661e+00 0.04901145 0.76412545 847.75 2.60054410e+00 2.92098741e-01 2.61689726e+00 0.11185335 0.84172170 848.00 2.54457306e+00 1.74750118e-01 2.55056654e+00 0.06856795 0.83500628 848.25 2.27534314e+00 6.29860013e-02 2.27621476e+00 0.02767491 0.78419436 848.50 2.66763103e+00 1.64225816e-01 2.67268132e+00 0.06148482 0.79289903 848.75 2.82526729e+00 2.06068675e-01 2.83277241e+00 0.07280883 0.85311193 849.00 2.80856734e+00 -2.91622669e-01 2.82366681e+00 -0.10346249 0.81024578 849.25 2.83438012e+00 -6.07334742e-01 2.89871802e+00 -0.21108240 0.79901019 849.50 2.72063097e+00 -6.87132313e-01 2.80606195e+00 -0.24738999 0.74852809 849.75 2.63967640e+00 -6.03285298e-01 2.70773792e+00 -0.22468622 0.70429188 850.00 2.40173248e+00 -3.42101577e-01 2.42597453e+00 -0.14148774 0.73507453 850.25 2.47350719e+00 -4.23558267e-01 2.50950979e+00 -0.16959308 0.77200741 850.50 2.85766986e+00 -4.41564975e-01 2.89158376e+00 -0.15330679 0.79524703 850.75 3.01469728e+00 -2.77417105e-01 3.02743454e+00 -0.09176311 0.79340942 851.00 3.25018360e+00 -4.34368145e-01 3.27908053e+00 -0.13285694 0.77348783 851.25 3.56867525e+00 -8.52050926e-01 3.66898267e+00 -0.23437060 0.82477753 851.50 3.97887239e+00 -9.87924922e-01 4.09968549e+00 -0.24337114 0.86912024 851.75 4.24046922e+00 -1.02711719e+00 4.36308938e+00 -0.23764095 0.85871682 852.00 4.19919373e+00 -1.47160920e+00 4.44959118e+00 -0.33707603 0.85776466 852.25 4.18716991e+00 -1.79219278e+00 4.55459623e+00 -0.40442589 0.85360567 852.50 4.53691652e+00 -2.34388057e+00 5.10660236e+00 -0.47685830 0.85869426 852.75 4.72530140e+00 -2.93194004e+00 5.56100222e+00 -0.55534009 0.87028105 853.00 4.51050639e+00 -3.87887827e+00 5.94898013e+00 -0.71025097 0.89927384 853.25 4.69774016e+00 -4.38804301e+00 6.42835003e+00 -0.75132545 0.91191390 853.50 4.44266902e+00 -4.95467794e+00 6.65478335e+00 -0.83982876 0.90190244 853.75 3.97388799e+00 -5.73081063e+00 6.97380644e+00 -0.96449668 0.86701589 854.00 3.18927434e+00 -6.40911015e+00 7.15878228e+00 -1.10905791 0.87385845 854.25 1.80572065e+00 -6.95566423e+00 7.18622933e+00 -1.31679891 0.86659394 854.50 7.56825142e-01 -7.40180058e+00 7.44039221e+00 -1.46890165 0.90939568 854.75 -2.78853202e-01 -7.19891220e+00 7.20431093e+00 -1.60951243 0.86974129 855.00 -1.13038209e+00 -6.96968541e+00 7.06075622e+00 -1.73158183 0.90935950 855.25 -1.86646664e+00 -6.53252144e+00 6.79393363e+00 -1.84910051 0.84217368 855.50 -2.84116004e+00 -5.85316318e+00 6.50628232e+00 -2.02270065 0.86762699 855.75 -2.54905503e+00 -4.62081386e+00 5.27727224e+00 -2.07490264 0.83538149 856.00 -2.58393484e+00 -3.88419260e+00 4.66515503e+00 -2.15781318 0.81469541 856.25 -2.82320363e+00 -3.62707171e+00 4.59631677e+00 -2.23220836 0.82746722 856.50 -3.00851266e+00 -3.28062472e+00 4.45125229e+00 -2.31295447 0.83416233 856.75 -3.28237943e+00 -2.36020399e+00 4.04284276e+00 -2.51819372 0.80609386 857.00 -3.35007207e+00 -2.13992700e+00 3.97520697e+00 -2.57315223 0.80943093 857.25 -3.13017502e+00 -1.97648476e+00 3.70195727e+00 -2.57838325 0.82378050 857.50 -3.14200343e+00 -1.70608786e+00 3.57532115e+00 -2.64414452 0.82512459 857.75 -2.99588772e+00 -1.46779690e+00 3.33613114e+00 -2.68602763 0.85394547 858.00 -2.93751017e+00 -1.43211393e+00 3.26801412e+00 -2.68797358 0.84635478 858.25 -2.70698802e+00 -7.71455025e-01 2.81476944e+00 -2.86396599 0.82564904 858.50 -2.49111900e+00 -5.14114447e-01 2.54361702e+00 -2.93807111 0.83859102 858.75 -2.15693356e+00 -4.20682619e-01 2.19757509e+00 -2.94897339 0.81399987 859.00 -1.96916180e+00 -5.78828573e-01 2.05247185e+00 -2.85569857 0.81776648 859.25 -1.89090983e+00 -6.67630306e-01 2.00531050e+00 -2.80218231 0.86282802 859.50 -1.97759390e+00 -6.62229223e-01 2.08552756e+00 -2.81846321 0.88615672 859.75 -2.08448077e+00 -5.49252677e-01 2.15562951e+00 -2.88395261 0.90514906 860.00 -1.94476028e+00 -4.64503520e-01 1.99946394e+00 -2.90713653 0.87876590 860.25 -2.00365771e+00 -2.70386902e-01 2.02181931e+00 -3.00745632 0.91772421 860.50 -1.94588514e+00 -1.89604240e-01 1.95510070e+00 -3.04446072 0.90606029 860.75 -1.59049018e+00 -1.16605882e-01 1.59475889e+00 -3.06840916 0.83268550 861.00 -1.40383149e+00 -1.53407426e-01 1.41218862e+00 -3.03274688 0.81268574 861.25 -1.16066775e+00 -2.28965649e-01 1.18303631e+00 -2.94682287 0.81207721 861.50 -1.11023876e+00 -3.76100570e-01 1.17221232e+00 -2.81496924 0.80756862 861.75 -1.13617252e+00 -5.50455994e-01 1.26249349e+00 -2.69043572 0.84698170 862.00 -1.29589773e+00 -6.21190677e-01 1.43709039e+00 -2.69459978 0.85763765 862.25 -1.43387802e+00 -7.49693291e-01 1.61803777e+00 -2.65983798 0.93054936 862.50 -1.44063673e+00 -7.15958136e-01 1.60873561e+00 -2.68036925 0.92647761 862.75 -1.51822493e+00 -6.47942797e-01 1.65070797e+00 -2.73821821 0.91434611 863.00 -1.66239373e+00 -5.28195692e-01 1.74428886e+00 -2.83394839 0.91568679 863.25 -1.77498396e+00 -4.02037605e-01 1.81994568e+00 -2.91884895 0.93237113 863.50 -1.79491076e+00 -3.73932908e-01 1.83344770e+00 -2.93620091 0.92159850 863.75 -1.74775727e+00 -2.73192248e-01 1.76897979e+00 -2.98653717 0.95513191 864.00 -1.74307811e+00 -1.71188340e-01 1.75146418e+00 -3.04369623 0.95029702 864.25 -1.73986715e+00 -5.77663165e-02 1.74082585e+00 -3.10840328 0.95448657 864.50 -1.67017972e+00 2.81547329e-02 1.67041701e+00 3.12473694 0.94498841 864.75 -1.66308896e+00 1.04714815e-01 1.66638233e+00 3.07871161 0.95912032 865.00 -1.57140520e+00 1.02338486e-01 1.57473409e+00 3.07655903 0.94309109 865.25 -1.55239873e+00 8.89990225e-02 1.55494780e+00 3.08432534 0.95144787 865.50 -1.53021524e+00 7.17523506e-02 1.53189656e+00 3.09473661 0.94800961 865.75 -1.52439935e+00 1.00122289e-01 1.52768382e+00 3.07600702 0.94597505 866.00 -1.49644081e+00 1.28166563e-01 1.50191936e+00 3.05615356 0.93782051 866.25 -1.53712581e+00 1.70043690e-01 1.54650270e+00 3.03141619 0.96377766 866.50 -1.53727247e+00 2.53557173e-01 1.55804297e+00 2.97812479 0.95663971 866.75 -1.49303042e+00 3.60092746e-01 1.53584069e+00 2.90492992 0.94186229 867.00 -1.40205487e+00 4.10307210e-01 1.46085929e+00 2.85689527 0.92565713 867.25 -1.36436130e+00 4.98624818e-01 1.45262124e+00 2.79120849 0.93840333 867.50 -1.23733353e+00 4.91210966e-01 1.33127100e+00 2.76368245 0.92300347 867.75 -1.14224754e+00 4.48215760e-01 1.22703986e+00 2.76765677 0.92041778 868.00 -1.04810609e+00 3.64992827e-01 1.10984059e+00 2.80648631 0.91280523 868.25 -1.03025409e+00 3.64701332e-01 1.09290007e+00 2.80136625 0.91921683 868.50 -9.28596980e-01 3.13441100e-01 9.80070239e-01 2.81605850 0.90066687 868.75 -9.37215711e-01 2.72478924e-01 9.76021544e-01 2.85865983 0.90181512 869.00 -9.70392398e-01 2.38778449e-01 9.99338058e-01 2.90032206 0.88953439 869.25 -9.95534024e-01 2.16557804e-01 1.01881562e+00 2.92740022 0.91006429 869.50 -1.10352692e+00 2.86755312e-01 1.14017555e+00 2.88736184 0.90951304 869.75 -1.09022216e+00 3.45708068e-01 1.14372131e+00 2.83452369 0.90885811 870.00 -1.05394775e+00 3.71812196e-01 1.11760913e+00 2.80244294 0.91043170 870.25 -1.03150327e+00 4.25483927e-01 1.11581162e+00 2.75036633 0.90147269 870.50 -1.05917588e+00 4.23698147e-01 1.14077765e+00 2.76106365 0.86664119 870.75 -9.80509356e-01 3.98271703e-01 1.05830948e+00 2.75576270 0.80038373 871.00 -8.20073510e-01 3.32999292e-01 8.85104000e-01 2.75587283 0.80330228 871.25 -7.98192325e-01 2.71315353e-01 8.43043895e-01 2.81393280 0.77302425 871.50 -6.99627405e-01 8.28162629e-02 7.04511915e-01 3.02376897 0.67392736 871.75 -6.93139789e-01 1.56581824e-03 6.93141558e-01 3.13933364 0.67756729 872.00 -8.29315826e-01 -2.04418918e-01 8.54138065e-01 -2.89991926 0.76588052 872.25 -9.48621326e-01 -3.16412557e-01 9.99999663e-01 -2.81964719 0.77149267 872.50 -1.26648644e+00 -4.45052369e-01 1.34240810e+00 -2.80366481 0.83464393 872.75 -1.41305983e+00 -4.03440974e-01 1.46952465e+00 -2.86348301 0.83518679 873.00 -1.64193645e+00 -3.23226936e-01 1.67344882e+00 -2.94722088 0.79969227 873.25 -1.89666803e+00 -2.57122456e-01 1.91401713e+00 -3.00684874 0.83259714 873.50 -2.15967833e+00 -4.92558364e-02 2.16023994e+00 -3.11878958 0.87254443 873.75 -2.13959014e+00 1.83359191e-01 2.14743256e+00 3.05610325 0.85415237 874.00 -2.17541938e+00 6.98253708e-01 2.28473362e+00 2.83100616 0.85703364 874.25 -2.31746741e+00 9.37116281e-01 2.49976841e+00 2.75732399 0.82804649 874.50 -2.29276317e+00 7.71926015e-01 2.41922151e+00 2.81683371 0.80350432 874.75 -2.33602875e+00 8.65756445e-01 2.49129776e+00 2.78667598 0.78798209 875.00 -2.34415209e+00 1.21209697e+00 2.63898239e+00 2.66438038 0.86084962 875.25 -2.40052204e+00 1.38537659e+00 2.77160140e+00 2.61817056 0.88828277 875.50 -2.57802252e+00 1.42840172e+00 2.94729225e+00 2.63563101 0.88757755 875.75 -2.45375631e+00 1.29486601e+00 2.77445455e+00 2.65602540 0.88047566 876.00 -2.39115506e+00 1.32384700e+00 2.73316545e+00 2.63595658 0.89587929 876.25 -2.47536827e+00 1.49653516e+00 2.89258804e+00 2.59781911 0.87797989 876.50 -2.63551477e+00 1.75448242e+00 3.16609328e+00 2.55425426 0.87083344 876.75 -2.52874790e+00 2.22386804e+00 3.36751466e+00 2.42025661 0.86425655 877.00 -2.48611584e+00 2.44550470e+00 3.48730056e+00 2.36442915 0.86299007 877.25 -2.66233549e+00 2.49103477e+00 3.64599568e+00 2.38942278 0.86455073 877.50 -2.62540065e+00 2.40396892e+00 3.55974650e+00 2.40019380 0.85147380 877.75 -2.28472755e+00 2.82018129e+00 3.62951822e+00 2.25168666 0.77142580 878.00 -2.28824911e+00 3.26517664e+00 3.98716221e+00 2.18206174 0.79320237 878.25 -2.28853444e+00 3.00720672e+00 3.77897899e+00 2.22131090 0.66029003 878.50 -2.64045453e+00 2.93528837e+00 3.94815374e+00 2.30336575 0.62180334 878.75 -2.11871089e+00 3.17798172e+00 3.81948998e+00 2.15881122 0.53342722 879.00 -2.03204930e+00 2.89199028e+00 3.53452007e+00 2.18329683 0.46374731 879.25 -2.17962843e+00 1.88608053e+00 2.88237399e+00 2.42827033 0.24336246 879.50 -1.71832186e+00 1.26149545e+00 2.13166620e+00 2.50831694 0.14467962 879.75 -1.46998921e+00 4.58059615e-01 1.53970350e+00 2.83952112 0.07209054 880.00 -1.90603021e+00 9.57714823e-02 1.90843479e+00 3.09138830 0.10725545 880.25 -2.16772470e+00 -1.35691307e+00 2.55738997e+00 -2.58230194 0.24824948 880.50 -1.42166012e+00 -2.00998459e+00 2.46194142e+00 -2.18640418 0.29202915 880.75 -6.91033976e-01 -1.81561264e+00 1.94267270e+00 -1.93447320 0.35415140 881.00 -1.01799260e+00 -1.62931381e+00 1.92119037e+00 -2.12925063 0.40409274 881.25 -1.52420363e+00 -1.74778271e+00 2.31903883e+00 -2.28796924 0.60470407 881.50 -1.20945775e+00 -1.57264151e+00 1.98393281e+00 -2.22638549 0.56393799 881.75 -6.13629015e-01 -1.19486194e+00 1.34321839e+00 -2.04523016 0.45506831 882.00 -4.40781292e-01 -1.12062827e+00 1.20419926e+00 -1.94554305 0.42835971 882.25 -3.97213209e-01 -7.00728249e-01 8.05480237e-01 -2.08648993 0.29241692 882.50 -1.85304506e-01 -5.38807493e-01 5.69781778e-01 -1.90204083 0.18461369 882.75 3.29294668e-02 -2.08243017e-01 2.10830510e-01 -1.41396492 0.03467217 883.00 1.30901703e-01 6.18527860e-03 1.31047753e-01 0.04721620 0.01282839 883.25 2.40523712e-01 -9.87385005e-03 2.40726294e-01 -0.04102843 0.04490409 883.50 2.58520303e-01 8.76238528e-02 2.72966457e-01 0.32679144 0.06226453 883.75 4.58128907e-01 5.05803511e-01 6.82436288e-01 0.83481635 0.38776843 884.00 4.74463305e-01 7.06232902e-01 8.50811577e-01 0.97923264 0.49919298 884.25 5.05464805e-01 9.76452149e-01 1.09952420e+00 1.09312511 0.74894718 884.50 5.34277875e-01 9.70299000e-01 1.10767008e+00 1.06746787 0.68024085 884.75 6.48880318e-01 1.00861198e+00 1.19930972e+00 0.99911734 0.53940184 885.00 7.17561834e-01 8.00336847e-01 1.07491118e+00 0.83987684 0.33096831 885.25 8.46318878e-01 6.56571077e-01 1.07114015e+00 0.65980739 0.21434508 885.50 8.41022775e-01 4.68639277e-01 9.62778313e-01 0.50837364 0.17041067 885.75 1.01400883e+00 -1.99657966e-01 1.03347821e+00 -0.19441267 0.18590320 886.00 9.61472763e-01 -2.18940892e-01 9.86085690e-01 -0.22389624 0.24737225 886.25 9.16662278e-01 -3.47296745e-01 9.80247296e-01 -0.36216009 0.33137923 886.50 1.03899117e+00 -1.04844797e-01 1.04426773e+00 -0.10056975 0.40398201 886.75 1.28945189e+00 3.79139621e-01 1.34403610e+00 0.28597226 0.55536307 887.00 1.99190174e+00 5.40328960e-01 2.06388661e+00 0.26488851 0.65763367 887.25 2.53731551e+00 7.03599126e-01 2.63306318e+00 0.27050381 0.70806900 887.50 3.39435431e+00 1.87263411e-01 3.39951596e+00 0.05511321 0.72861365 887.75 3.48573132e+00 -2.04890135e-01 3.49174782e+00 -0.05871211 0.71217161 888.00 2.74209576e+00 -3.73066478e-01 2.76735754e+00 -0.13522135 0.68685940 888.25 2.48288911e+00 -3.52934067e-01 2.50784784e+00 -0.14120058 0.66590289 888.50 2.45244778e+00 -6.70008159e-02 2.45336284e+00 -0.02731318 0.71958852 888.75 2.46063971e+00 3.74228277e-02 2.46092427e+00 0.01520740 0.75410715 889.00 2.44279465e+00 5.46163435e-01 2.50310611e+00 0.21996378 0.82470708 889.25 2.32656995e+00 6.88707902e-01 2.42636483e+00 0.28780011 0.81634210 889.50 2.13994793e+00 1.18702196e+00 2.44712041e+00 0.50644193 0.76656122 889.75 2.19480090e+00 1.57257795e+00 2.70002822e+00 0.62171510 0.83138270 890.00 2.15359977e+00 1.75067208e+00 2.77539992e+00 0.68256048 0.84711696 890.25 2.14077155e+00 1.69903331e+00 2.73306001e+00 0.67085984 0.82337386 890.50 1.75200686e+00 1.58897871e+00 2.36524446e+00 0.73664041 0.73468962 890.75 1.59508386e+00 1.51717280e+00 2.20138725e+00 0.76036977 0.68632937 891.00 1.46933714e+00 1.10587585e+00 1.83899783e+00 0.64518594 0.63763606 891.25 1.40560315e+00 8.79978771e-01 1.65833738e+00 0.55935448 0.57754456 891.50 1.32605013e+00 9.38928329e-01 1.62480625e+00 0.61611755 0.48391808 891.75 1.32485621e+00 1.02388644e+00 1.67439166e+00 0.65795189 0.52943926 892.00 9.40473150e-01 1.21805024e+00 1.53887495e+00 0.91329208 0.57557297 892.25 1.20169348e+00 1.09506463e+00 1.62580250e+00 0.73900567 0.62723222 892.50 1.35861098e+00 1.07818482e+00 1.73444697e+00 0.67082230 0.75180787 892.75 1.40012360e+00 9.40467130e-01 1.68666076e+00 0.59148115 0.70845493 893.00 1.76539729e+00 4.19792838e-01 1.81462217e+00 0.23345377 0.75674278 893.25 1.87395589e+00 2.31952671e-01 1.88825653e+00 0.12315065 0.72957681 893.50 2.46494180e+00 -1.07694819e-01 2.46729331e+00 -0.04366285 0.84166189 893.75 2.61211537e+00 -2.70060343e-01 2.62603870e+00 -0.10302158 0.88172326 894.00 2.62912763e+00 -3.69577030e-01 2.65497632e+00 -0.13965515 0.90359132 894.25 2.95686427e+00 -4.24305768e-01 2.98715277e+00 -0.14252559 0.90677218 894.50 3.24607925e+00 -5.33876793e-01 3.28968918e+00 -0.16300886 0.90870734 894.75 3.17090645e+00 -7.17643260e-01 3.25110129e+00 -0.22257160 0.84308471 895.00 3.21071940e+00 -9.12138769e-01 3.33777114e+00 -0.27679890 0.84559503 895.25 3.13527597e+00 -1.15951077e+00 3.34281628e+00 -0.35422804 0.74581454 895.50 3.47758363e+00 -1.61987128e+00 3.83634864e+00 -0.43591828 0.77328955 895.75 3.87307100e+00 -1.56032981e+00 4.17556081e+00 -0.38297489 0.78364920 896.00 4.14320020e+00 -1.29276899e+00 4.34020271e+00 -0.30244920 0.73387070 896.25 4.60031023e+00 -1.32013563e+00 4.78598081e+00 -0.27945712 0.83065264 896.50 4.64107879e+00 -1.30157765e+00 4.82013659e+00 -0.27342336 0.85599270 896.75 4.14851076e+00 -1.59127191e+00 4.44322944e+00 -0.36626865 0.74722760 897.00 4.15730931e+00 -1.79498681e+00 4.52826660e+00 -0.40758793 0.72311287 897.25 3.93702686e+00 -1.85800911e+00 4.35343294e+00 -0.44094218 0.67756633 897.50 3.91564559e+00 -1.88468767e+00 4.34561020e+00 -0.44859414 0.62237417 897.75 4.01316702e+00 -1.61942728e+00 4.32759220e+00 -0.38354448 0.57695574 898.00 3.74443583e+00 -1.70017508e+00 4.11234666e+00 -0.42621990 0.49498491 898.25 2.57823266e+00 -2.31052534e+00 3.46205300e+00 -0.73069302 0.33106803 898.50 1.16036890e+00 -2.84514085e+00 3.07266700e+00 -1.18354765 0.29077312 898.75 4.52723216e-01 -3.06395000e+00 3.09721616e+00 -1.42409973 0.22934804 899.00 -1.77496712e-01 -2.38663527e+00 2.39322649e+00 -1.64503077 0.16006341 899.25 -1.66016033e+00 -2.07031130e+00 2.65373722e+00 -2.24668818 0.20464611 899.50 -1.96592025e+00 -2.57985643e+00 3.24353228e+00 -2.22195038 0.28287868 899.75 -2.16557711e+00 -1.61571015e+00 2.70189628e+00 -2.50060021 0.25207940 900.00 -2.38455947e+00 -1.17092741e+00 2.65653814e+00 -2.68513420 0.27640882 900.25 -3.21304731e+00 -5.24888941e-01 3.25563841e+00 -2.97966131 0.38028066 900.50 -2.99917819e+00 -2.79293830e-01 3.01215452e+00 -3.04873700 0.27247428 900.75 -2.31513583e+00 5.45015456e-01 2.37842295e+00 2.91038837 0.20329404 901.00 -2.01810028e+00 4.41903661e-01 2.06591568e+00 2.92602490 0.20888867 901.25 -1.58713254e+00 5.02353295e-01 1.66473677e+00 2.83505302 0.11252957 901.50 -1.74042668e+00 4.97682074e-01 1.81018576e+00 2.86307133 0.15235265 901.75 -1.18245738e+00 1.58556177e+00 1.97793114e+00 2.21158189 0.28977848 902.00 -1.04053924e+00 1.82085159e+00 2.09719394e+00 2.08996423 0.33335871 902.25 -1.50451087e+00 1.53418972e+00 2.14878828e+00 2.34642785 0.30209630 902.50 -1.53070215e+00 1.88706804e+00 2.42983021e+00 2.25230138 0.45358250 902.75 -1.05365753e+00 2.29793322e+00 2.52798166e+00 2.00071616 0.60262291 903.00 -9.05451089e-01 2.52822816e+00 2.68547562e+00 1.91470134 0.68141017 903.25 -8.61884558e-01 2.27738330e+00 2.43501944e+00 1.93259162 0.69264871 903.50 -5.94767689e-01 2.17742909e+00 2.25719872e+00 1.83744305 0.64257008 903.75 -5.51199361e-01 2.30621060e+00 2.37116597e+00 1.80540172 0.77397059 904.00 -6.88617696e-01 2.19504916e+00 2.30052932e+00 1.87478682 0.82582383 904.25 -6.27493659e-01 2.09236832e+00 2.18443436e+00 1.86215804 0.80003129 904.50 -7.14225083e-01 2.08316644e+00 2.20220342e+00 1.90109222 0.84852338 904.75 -7.52525292e-01 2.13952695e+00 2.26801011e+00 1.90900714 0.92415816 905.00 -5.98543996e-01 2.24922333e+00 2.32750092e+00 1.83088026 0.93294406 905.25 -4.27740037e-01 2.38148521e+00 2.41959363e+00 1.74851208 0.94307172 905.50 -3.29758430e-01 2.34486835e+00 2.36794177e+00 1.71050993 0.93992565 905.75 -2.35836624e-01 2.30186505e+00 2.31391478e+00 1.67289466 0.94184227 906.00 -8.95366395e-02 2.10128005e+00 2.10318679e+00 1.61338109 0.93436023 906.25 -5.90974142e-02 1.92363036e+00 1.92453794e+00 1.60150848 0.93564491 906.50 -4.40448680e-02 1.86402319e+00 1.86454348e+00 1.59442086 0.94327077 906.75 -2.95093105e-02 1.78501218e+00 1.78525608e+00 1.58732653 0.93460811 907.00 -6.79078502e-02 1.74292145e+00 1.74424386e+00 1.60973871 0.91920493 907.25 -7.23988420e-03 1.57490128e+00 1.57491792e+00 1.57539333 0.89302907 907.50 2.09387898e-02 1.39358025e+00 1.39373754e+00 1.55577228 0.87196783 907.75 -6.52306941e-02 1.28551059e+00 1.28716453e+00 1.62149587 0.88410001 908.00 -2.26464744e-01 1.18821751e+00 1.20960619e+00 1.75912958 0.89316504 908.25 -3.35076763e-01 1.18654190e+00 1.23294693e+00 1.84602708 0.93024847 908.50 -3.86626039e-01 1.22937363e+00 1.28873551e+00 1.87549336 0.92661445 908.75 -4.61497186e-01 1.26829229e+00 1.34964624e+00 1.91977622 0.93999611 909.00 -4.05501115e-01 1.26644329e+00 1.32977809e+00 1.88067064 0.93350702 909.25 -4.03271373e-01 1.25553671e+00 1.31871158e+00 1.88158236 0.93662891 909.50 -4.07355717e-01 1.31820764e+00 1.37971376e+00 1.87050988 0.96566080 909.75 -3.87032220e-01 1.30397326e+00 1.36019859e+00 1.85932389 0.97516509 910.00 -3.54896243e-01 1.24908985e+00 1.29852870e+00 1.84762499 0.96784231 910.25 -3.43118204e-01 1.24401777e+00 1.29046903e+00 1.83991966 0.96493522 910.50 -4.41389941e-01 1.18691844e+00 1.26633347e+00 1.92682790 0.95410196 910.75 -4.51981453e-01 1.14967784e+00 1.23533249e+00 1.94537278 0.94990828 911.00 -4.36428233e-01 1.11591059e+00 1.19821787e+00 1.94360340 0.94308859 911.25 -4.39055015e-01 1.05416420e+00 1.14194197e+00 1.96544189 0.93868763 911.50 -4.58495447e-01 9.48672960e-01 1.05365956e+00 2.02099644 0.91030560 911.75 -5.13849934e-01 9.25242647e-01 1.05835519e+00 2.07775131 0.87612347 912.00 -6.74615998e-01 9.17558500e-01 1.13886801e+00 2.20477705 0.81334390 912.25 -7.48336847e-01 9.06180477e-01 1.17523236e+00 2.26108073 0.77719796 912.50 -8.76851286e-01 1.12493656e+00 1.42630657e+00 2.23289135 0.77278934 912.75 -9.00801278e-01 1.14762377e+00 1.45893223e+00 2.23627882 0.73300303 913.00 -7.00500010e-01 1.04523959e+00 1.25826311e+00 2.16122818 0.63075119 913.25 -6.29494988e-01 1.07010122e+00 1.24152349e+00 2.10253683 0.58318114 913.50 -3.12269019e-01 1.09673165e+00 1.14032112e+00 1.84818290 0.71498373 913.75 -3.14875133e-01 1.07559057e+00 1.12073254e+00 1.85558511 0.70000853 914.00 -3.90713397e-01 1.03429726e+00 1.10563456e+00 1.93198221 0.67131955 914.25 -2.95492412e-01 9.92716362e-01 1.03576133e+00 1.86010538 0.61697844 914.50 -1.93957254e-01 1.21081961e+00 1.22625591e+00 1.72963367 0.79958183 914.75 -5.02452760e-02 1.23394122e+00 1.23496377e+00 1.61149319 0.81350025 915.00 1.50418227e-02 1.18571247e+00 1.18580788e+00 1.55811111 0.81848878 915.25 1.28381343e-01 1.22752406e+00 1.23421922e+00 1.46658957 0.76677573 915.50 2.16895038e-01 1.25553501e+00 1.27413171e+00 1.39973358 0.79229570 915.75 2.17923384e-01 1.18955493e+00 1.20935170e+00 1.38960806 0.76758211 916.00 3.65628220e-01 9.68773143e-01 1.03547351e+00 1.20991125 0.67225919 916.25 7.01563841e-01 7.06296465e-01 9.95513195e-01 0.78875972 0.59666011 916.50 8.03650722e-01 4.18531699e-01 9.06103341e-01 0.48013942 0.57836356 916.75 5.00413253e-01 -1.88521589e-01 5.34746494e-01 -0.36028810 0.22277932 917.00 1.69793206e-01 -5.68092075e-01 5.92923552e-01 -1.28036439 0.28515530 917.25 -2.67592866e-01 -6.15773975e-01 6.71404149e-01 -1.98073934 0.27203448 917.50 -5.51293998e-01 -8.02608805e-01 9.73707330e-01 -2.17266090 0.39830887 917.75 -8.57689025e-01 -6.11701295e-01 1.05347470e+00 -2.52206440 0.49763766 918.00 -1.28426578e+00 -3.27322938e-01 1.32532219e+00 -2.89203419 0.67769944 918.25 -1.62827677e+00 -4.05245472e-02 1.62878098e+00 -3.11670979 0.70760372 918.50 -1.82548668e+00 1.76682714e-01 1.83401702e+00 3.04510655 0.76602351 918.75 -1.76416400e+00 3.66376642e-01 1.80180645e+00 2.93682619 0.81624601 919.00 -1.77993620e+00 4.98311023e-01 1.84837409e+00 2.86862100 0.86207486 919.25 -1.53426257e+00 7.05422809e-01 1.68866307e+00 2.71063574 0.84391891 919.50 -1.56436373e+00 7.57657438e-01 1.73818258e+00 2.69056506 0.85110474 919.75 -1.80615384e+00 8.51087085e-01 1.99663240e+00 2.70123693 0.85252469 920.00 -1.87288286e+00 9.62774440e-01 2.10585489e+00 2.66676030 0.89342194 920.25 -1.71755275e+00 1.13577138e+00 2.05911730e+00 2.55733338 0.90639956 920.50 -1.65300344e+00 1.16715121e+00 2.02352720e+00 2.52679839 0.90121831 920.75 -1.62084546e+00 1.31315938e+00 2.08603154e+00 2.46068155 0.91077979 921.00 -1.62593971e+00 1.29510780e+00 2.07869771e+00 2.46897189 0.90917337 921.25 -1.48256589e+00 1.30228383e+00 1.97330809e+00 2.42084101 0.90185050 921.50 -1.40777143e+00 1.36934021e+00 1.96390249e+00 2.37003216 0.89575325 921.75 -1.22855155e+00 1.54019062e+00 1.97015889e+00 2.24411004 0.90352005 922.00 -1.24308835e+00 1.53095942e+00 1.97208149e+00 2.25279167 0.90767004 922.25 -1.36404328e+00 1.41497303e+00 1.96539124e+00 2.33787000 0.91761449 922.50 -1.33504997e+00 1.52707980e+00 2.02838141e+00 2.28920156 0.91910080 922.75 -1.33236918e+00 1.55914993e+00 2.05089154e+00 2.27792509 0.92648867 923.00 -1.30416916e+00 1.50770734e+00 1.99349909e+00 2.28393534 0.90970544 923.25 -1.29261393e+00 1.41697073e+00 1.91798249e+00 2.31033152 0.88437634 923.50 -1.21413528e+00 1.54919760e+00 1.96828293e+00 2.23553057 0.90811380 923.75 -1.20637227e+00 1.67241623e+00 2.06211302e+00 2.19569800 0.95512662 924.00 -1.23381061e+00 1.70115626e+00 2.10148072e+00 2.19828649 0.95464543 924.25 -1.22087828e+00 1.74942945e+00 2.13331835e+00 2.18009285 0.96788833 924.50 -1.21510599e+00 1.72321023e+00 2.10853885e+00 2.18496422 0.96905601 924.75 -1.13385888e+00 1.75973856e+00 2.09339814e+00 2.14317790 0.94560431 925.00 -1.14930404e+00 1.76222782e+00 2.10388846e+00 2.14870823 0.92556694 925.25 -1.10637306e+00 1.83474853e+00 2.14251336e+00 2.11342666 0.91572235 925.50 -1.07542076e+00 1.95045600e+00 2.22728723e+00 2.07468990 0.93673089 925.75 -1.00509058e+00 2.06069326e+00 2.29274155e+00 2.02459108 0.95742080 926.00 -9.32449818e-01 2.06835053e+00 2.26881832e+00 1.99433036 0.96020085 926.25 -8.64082042e-01 2.00490956e+00 2.18318577e+00 1.97772374 0.95997295 926.50 -8.17080559e-01 2.01976535e+00 2.17877780e+00 1.95521235 0.93973183 926.75 -7.41064844e-01 2.00542765e+00 2.13797034e+00 1.92476241 0.92691928 927.00 -7.21718606e-01 1.99241921e+00 2.11910643e+00 1.91832669 0.90560202 927.25 -8.87766525e-01 1.83137043e+00 2.03520197e+00 2.02217397 0.87340486 927.50 -9.89469154e-01 1.79949912e+00 2.05359351e+00 2.07353058 0.82833257 927.75 -1.08363069e+00 2.05916625e+00 2.32689087e+00 2.05522062 0.82899522 928.00 -1.29023672e+00 2.36112066e+00 2.69065077e+00 2.07091069 0.82407540 928.25 -1.44197432e+00 2.57960286e+00 2.95527340e+00 2.08051606 0.84011610 928.50 -1.20532462e+00 2.86990482e+00 3.11274174e+00 1.96841383 0.82297256 928.75 -1.10580192e+00 3.48998105e+00 3.66097877e+00 1.87763963 0.83901750 929.00 -4.12347527e-01 3.90897277e+00 3.93066134e+00 1.67589508 0.82145462 929.25 5.32553966e-02 4.07256077e+00 4.07290896e+00 1.55772044 0.79161778 929.50 1.03752162e-01 4.17930333e+00 4.18059097e+00 1.54597620 0.79497692 929.75 5.98805934e-01 4.34192949e+00 4.38302638e+00 1.43374844 0.76289636 930.00 2.16624252e+00 4.32554534e+00 4.83765947e+00 1.10650718 0.76346885 930.25 3.05657329e+00 4.39355723e+00 5.35219445e+00 0.96296586 0.81940824 930.50 3.69338251e+00 3.40612656e+00 5.02421860e+00 0.74495884 0.82869229 930.75 3.98886308e+00 2.68026455e+00 4.80570981e+00 0.59164240 0.78527707 931.00 4.25890558e+00 1.58290627e+00 4.54355247e+00 0.35584779 0.68309801 931.25 4.75369224e+00 1.11196849e+00 4.88201432e+00 0.22978521 0.68934990 931.50 4.86114242e+00 6.13628014e-01 4.89971887e+00 0.12556710 0.66024157 931.75 4.30251548e+00 -5.83825251e-01 4.34194558e+00 -0.13487018 0.50536269 932.00 2.57965039e+00 -2.94619182e+00 3.91594719e+00 -0.85163336 0.37976564 932.25 2.23245232e+00 -3.22855026e+00 3.92522358e+00 -0.96581677 0.34558670 932.50 -9.73627611e-01 -3.33616521e+00 3.47533438e+00 -1.85475049 0.24430692 932.75 -2.02404122e+00 -3.09386740e+00 3.69712839e+00 -2.15012594 0.25853750 933.00 -3.46754174e+00 2.30199365e-01 3.47517445e+00 3.07530302 0.17050165 933.25 -4.11530332e+00 1.47948891e+00 4.37316920e+00 2.79647174 0.25154374 933.50 -2.52212055e+00 3.59579080e+00 4.39212972e+00 2.18246740 0.27357407 933.75 -1.26667147e+00 3.63305738e+00 3.84753980e+00 1.90626944 0.30214240 934.00 1.26478771e-01 3.86326366e+00 3.86533349e+00 1.53806918 0.40991544 934.25 6.08466515e-01 3.78283966e+00 3.83146283e+00 1.41131323 0.46725989 934.50 1.38937059e+00 2.61189794e+00 2.95843903e+00 1.08192512 0.54146626 934.75 1.37076881e+00 1.92800228e+00 2.36562887e+00 0.95273996 0.42967563 935.00 8.19740641e-01 9.54452047e-01 1.25815477e+00 0.86118104 0.18041047 935.25 4.53566309e-01 9.06989320e-01 1.01407693e+00 1.10708552 0.17790846 935.50 3.02771333e-01 1.13968876e+00 1.17922049e+00 1.31113268 0.44404148 935.75 3.43194628e-01 1.43454366e+00 1.47502476e+00 1.33597377 0.54355015 936.00 5.36569872e-01 1.29091813e+00 1.39799029e+00 1.17687196 0.67503558 936.25 7.39336914e-01 1.24074446e+00 1.44432194e+00 1.03341049 0.64264169 936.50 1.12325872e+00 1.15027538e+00 1.60774488e+00 0.79728072 0.64383286 936.75 1.15263068e+00 9.49206977e-01 1.49316823e+00 0.68891493 0.60225472 937.00 9.13446206e-01 8.97697145e-01 1.28072016e+00 0.77670274 0.53694944 937.25 8.25224024e-01 6.40590003e-01 1.04467710e+00 0.66009799 0.46181097 937.50 9.50366489e-01 4.07691236e-01 1.03412214e+00 0.40523959 0.45996611 937.75 8.20088941e-01 2.58012632e-01 8.59718785e-01 0.30481093 0.32378953 938.00 7.95403372e-01 -1.20587516e-02 7.95494775e-01 -0.01515939 0.35957412 938.25 4.75692480e-01 -1.20430464e-01 4.90700349e-01 -0.24795877 0.28464664 938.50 2.75589648e-01 -9.16968239e-02 2.90444421e-01 -0.32120706 0.16279724 938.75 1.37692020e-01 -1.44228478e-01 1.99401470e-01 -0.80857947 0.06568425 939.00 2.04845070e-06 -2.36603341e-01 2.36603341e-01 -1.57078767 0.09414832 939.25 -1.23783751e-01 -2.56547494e-01 2.84849142e-01 -2.02034487 0.22313141 939.50 -2.03199759e-01 -2.02842154e-01 2.87115102e-01 -2.35707520 0.29975736 939.75 -2.30992776e-01 -1.01542798e-01 2.52326381e-01 -2.72742685 0.19166898 940.00 -2.55333430e-01 -1.13641934e-01 2.79481036e-01 -2.72284384 0.17080504 940.25 -4.02730511e-01 -1.54070570e-01 4.31195553e-01 -2.77620627 0.30088727 940.50 -4.08478134e-01 -1.05025634e-01 4.21763879e-01 -2.88992932 0.34220690 940.75 -5.60257683e-01 -1.48325507e-01 5.79559425e-01 -2.88278506 0.37750072 941.00 -6.73397958e-01 -1.94241725e-01 7.00852808e-01 -2.86076547 0.50738418 941.25 -7.84796713e-01 -4.91302712e-02 7.86333050e-01 -3.07907170 0.63103582 941.50 -7.60000183e-01 -5.47450278e-02 7.61969354e-01 -3.06968394 0.59632723 941.75 -7.94325291e-01 -7.00978618e-02 7.97412301e-01 -3.05357237 0.56641325 942.00 -9.36244021e-01 -3.40965064e-02 9.36864686e-01 -3.10519034 0.59303125 942.25 -1.08358018e+00 5.31771871e-03 1.08359322e+00 3.13668515 0.57571458 942.50 -1.06218027e+00 1.86679439e-01 1.07846008e+00 2.96761822 0.54076191 942.75 -1.23655561e+00 6.12130726e-01 1.37977310e+00 2.68192985 0.54519610 943.00 -1.34801998e+00 7.07141809e-01 1.52223763e+00 2.65847642 0.64704035 943.25 -1.25539849e+00 7.68272951e-01 1.47182495e+00 2.59241424 0.67294443 943.50 -1.29161366e+00 8.00338723e-01 1.51947620e+00 2.58685520 0.67395383 943.75 -1.14063512e+00 1.01323032e+00 1.52567498e+00 2.41527735 0.68739979 944.00 -1.04126868e+00 1.16696083e+00 1.56398147e+00 2.29933597 0.66644402 944.25 -9.92097424e-01 1.14560255e+00 1.51547435e+00 2.28450899 0.67691615 944.50 -8.75982785e-01 1.12431302e+00 1.42528089e+00 2.23267970 0.67709667 944.75 -8.91344549e-01 1.13317884e+00 1.44173139e+00 2.23730537 0.66215763 945.00 -8.49377242e-01 1.15600824e+00 1.43450227e+00 2.20446589 0.66897547 945.25 -6.53693323e-01 1.04199120e+00 1.23006529e+00 2.13108385 0.61666281 945.50 -9.18790936e-01 1.05302444e+00 1.39751109e+00 2.28822326 0.72224458 945.75 -1.05761748e+00 1.08102448e+00 1.51233881e+00 2.34525013 0.72625883 946.00 -9.68486806e-01 1.22384855e+00 1.56069599e+00 2.24023769 0.71805774 946.25 -1.07417330e+00 1.46405216e+00 1.81584609e+00 2.20378278 0.77746994 946.50 -1.05135624e+00 1.43916260e+00 1.78228475e+00 2.20172191 0.75996725 946.75 -1.12302568e+00 1.30878857e+00 1.72456203e+00 2.27995395 0.72465806 947.00 -1.07609692e+00 1.61979469e+00 1.94466434e+00 2.15718751 0.83872300 947.25 -9.81404100e-01 1.73139903e+00 1.99020014e+00 2.08646686 0.87435912 947.50 -9.60336173e-01 1.72456867e+00 1.97392570e+00 2.07888791 0.81660367 947.75 -8.25037321e-01 1.73700281e+00 1.92298345e+00 2.01422634 0.80050837 948.00 -7.65955377e-01 1.85238268e+00 2.00449725e+00 1.96288395 0.80026563 948.25 -7.11296380e-01 1.97664693e+00 2.10073216e+00 1.91621910 0.78135867 948.50 -8.79932820e-01 2.05021863e+00 2.23107108e+00 1.97621037 0.80146329 948.75 -9.44085753e-01 2.09860509e+00 2.30118257e+00 1.99353670 0.85362647 949.00 -9.28296395e-01 2.15271025e+00 2.34433266e+00 1.97792539 0.86990123 949.25 -1.04419846e+00 2.20879932e+00 2.44318334e+00 2.01240304 0.82936364 949.50 -8.32977097e-01 2.28672170e+00 2.43371054e+00 1.92012414 0.76473663 949.75 -6.30608374e-01 2.31155928e+00 2.39603281e+00 1.83712211 0.74507166 950.00 -7.06767687e-01 2.30186895e+00 2.40792883e+00 1.86869999 0.74600338 950.25 -5.96916251e-01 2.34799119e+00 2.42267861e+00 1.81974677 0.81905269 950.50 -4.26358726e-01 2.33251217e+00 2.37115896e+00 1.75158990 0.83560339 950.75 -3.70346111e-01 2.38400879e+00 2.41260319e+00 1.72491044 0.85228492 951.00 -4.76859132e-01 2.15117825e+00 2.20339794e+00 1.78894228 0.79682806 951.25 -5.72447666e-01 2.09614937e+00 2.17291015e+00 1.83739050 0.73427086 951.50 -3.57928062e-01 2.48123401e+00 2.50691737e+00 1.71406208 0.81002714 951.75 -2.53142204e-01 2.43495336e+00 2.44807656e+00 1.67438602 0.79890944 952.00 -5.08571854e-02 2.47687424e+00 2.47739631e+00 1.59132625 0.75609987 952.25 9.20407010e-02 2.67787911e+00 2.67946040e+00 1.53643911 0.78122380 952.50 1.55205311e-01 2.86182135e+00 2.86602688e+00 1.51661635 0.78836501 952.75 2.10600477e-01 2.92695447e+00 2.93452126e+00 1.49896803 0.85288794 953.00 2.13175557e-01 2.78125681e+00 2.78941450e+00 1.49429869 0.87418256 953.25 2.42828152e-01 2.87887872e+00 2.88910163e+00 1.48664734 0.83886361 953.50 3.26915506e-01 3.01996008e+00 3.03760311e+00 1.46296463 0.80439846 953.75 4.14551278e-01 3.16923235e+00 3.19623004e+00 1.44072983 0.76697243 954.00 1.17808504e+00 3.50683016e+00 3.69942456e+00 1.24670148 0.74313235 954.25 1.22167628e+00 3.46867666e+00 3.67752780e+00 1.23216080 0.74168994 954.50 1.64704086e+00 2.87099290e+00 3.30988577e+00 1.04995210 0.79080344 954.75 1.94997517e+00 2.68152836e+00 3.31556896e+00 0.94205548 0.80318044 955.00 2.28992117e+00 2.61614544e+00 3.47677378e+00 0.85179448 0.83021339 955.25 2.28892332e+00 2.26345541e+00 3.21906824e+00 0.77980380 0.82125690 955.50 2.08456433e+00 1.93853090e+00 2.84663143e+00 0.74911532 0.79239140 955.75 2.08876748e+00 1.73847127e+00 2.71757832e+00 0.69412533 0.76841675 956.00 2.17901315e+00 1.35079555e+00 2.56373691e+00 0.55493188 0.76376185 956.25 2.23184587e+00 1.23970738e+00 2.55303944e+00 0.50702763 0.75923428 956.50 2.29404501e+00 8.65990576e-01 2.45205673e+00 0.36095629 0.74970378 956.75 2.20511718e+00 7.55756153e-01 2.33103178e+00 0.33018210 0.78412504 957.00 2.06032836e+00 5.91858385e-01 2.14365326e+00 0.27973192 0.72911781 957.25 1.98509683e+00 5.05407080e-01 2.04842519e+00 0.24930404 0.73992923 957.50 1.68055165e+00 4.00857848e-01 1.72769814e+00 0.23415225 0.70171072 957.75 1.41917036e+00 2.87443123e-01 1.44798759e+00 0.19983962 0.61543350 958.00 1.22955023e+00 2.04648685e-01 1.24646495e+00 0.16492998 0.55267790 958.25 1.22859177e+00 5.45717769e-02 1.22980317e+00 0.04438898 0.53202066 958.50 1.14525191e+00 -2.71173981e-01 1.17691854e+00 -0.23249916 0.54513044 958.75 1.02546642e+00 -3.51860278e-01 1.08415268e+00 -0.33053450 0.57160387 959.00 9.14630516e-01 -4.33954636e-01 1.01235646e+00 -0.44300680 0.57803375 959.25 7.27586834e-01 -1.78628140e-01 7.49193309e-01 -0.24074613 0.35874257 959.50 2.79705253e-01 -2.07939714e-02 2.80477126e-01 -0.07420594 0.06197370 959.75 -2.36462920e-01 2.06294071e-01 3.13802416e-01 2.42422795 0.12044844 960.00 -2.88202910e-01 3.02130519e-01 4.17544929e-01 2.33260608 0.23381223 960.25 -3.60555150e-01 7.63128181e-01 8.44016965e-01 2.01217836 0.47884331 960.50 -4.20051653e-01 9.82905975e-01 1.06890016e+00 1.97466160 0.67664231 960.75 -5.20739576e-01 1.10716752e+00 1.22351528e+00 2.01043152 0.71836709 961.00 -5.33051964e-01 1.17581069e+00 1.29099774e+00 1.99643134 0.75829533 961.25 -4.92910734e-01 1.50971205e+00 1.58814089e+00 1.88637819 0.82407119 961.50 -4.23106863e-01 1.66492948e+00 1.71785028e+00 1.81965732 0.87237213 961.75 -6.81557748e-02 1.75162165e+00 1.75294713e+00 1.60968681 0.84386844 962.00 -6.96979007e-02 1.80401312e+00 1.80535901e+00 1.60941204 0.86964491 962.25 2.13278482e-02 1.73890341e+00 1.73903420e+00 1.55853183 0.88842611 962.50 7.96549072e-02 1.78195044e+00 1.78372987e+00 1.52612510 0.87736822 962.75 1.05289302e-01 1.81490732e+00 1.81795886e+00 1.51284768 0.80051587 963.00 1.06558756e-01 1.77235429e+00 1.77555470e+00 1.51074590 0.76492155 963.25 2.72695066e-02 1.91456184e+00 1.91475603e+00 1.55655408 0.72678375 963.50 1.38051858e-02 1.99190083e+00 1.99194867e+00 1.56386578 0.69839275 963.75 2.01676585e-01 2.07067634e+00 2.08047446e+00 1.47370608 0.69661951 964.00 2.11278724e-01 2.11603150e+00 2.12655308e+00 1.47127948 0.72840801 964.25 5.89919168e-01 2.07254881e+00 2.15486965e+00 1.29349512 0.70524532 964.50 8.41091155e-01 2.02642051e+00 2.19404066e+00 1.17737285 0.68213670 964.75 8.93261753e-01 2.04822237e+00 2.23453159e+00 1.15954845 0.69608918 965.00 7.83855702e-01 1.92254994e+00 2.07620520e+00 1.18365538 0.64704157 965.25 9.18575110e-01 1.75931381e+00 1.98468267e+00 1.08960874 0.44560972 965.50 7.45715688e-01 1.58983449e+00 1.75603690e+00 1.13221187 0.36523473 965.75 7.50714204e-01 9.08824132e-01 1.17878459e+00 0.88038490 0.24633672 966.00 8.46300471e-01 6.93669462e-01 1.09425857e+00 0.68660783 0.29432134 966.25 9.70903200e-01 6.63779655e-01 1.17611924e+00 0.59968354 0.26725458 966.50 1.16129058e+00 8.91421568e-01 1.46397686e+00 0.65467836 0.40797322 966.75 1.15452601e+00 8.23443591e-01 1.41809367e+00 0.61955066 0.54527533 967.00 1.19550562e+00 8.44912913e-01 1.46393699e+00 0.61523585 0.55864820 967.25 1.14848796e+00 7.76791033e-01 1.38651683e+00 0.59468321 0.49046346 967.50 9.54115768e-01 6.30465098e-01 1.14360095e+00 0.58391941 0.43963036 967.75 8.26790521e-01 6.42142200e-01 1.04686636e+00 0.66035167 0.36191580 968.00 9.38485535e-01 5.44872108e-01 1.08519156e+00 0.52602261 0.39526285 968.25 9.52632955e-01 4.37771067e-01 1.04840501e+00 0.43075738 0.50493090 968.50 9.52176122e-01 4.11572679e-01 1.03731935e+00 0.40799058 0.47450532 968.75 9.34089921e-01 3.76754319e-01 1.00720792e+00 0.38338098 0.46094224 969.00 8.27542388e-01 4.07107879e-01 9.22259849e-01 0.45718534 0.44960039 969.25 9.00761207e-01 5.19002831e-01 1.03958390e+00 0.52272249 0.56150230 969.50 9.41909862e-01 5.12169182e-01 1.07215272e+00 0.49803675 0.51169209 969.75 8.03700205e-01 3.46978029e-01 8.75401492e-01 0.40755355 0.37738246 970.00 8.32288861e-01 1.67969782e-01 8.49069253e-01 0.19914176 0.36373109 970.25 8.30037147e-01 3.03034710e-01 8.83624185e-01 0.35005050 0.36944697 970.50 6.34220606e-01 3.38113193e-01 7.18718518e-01 0.48978816 0.30318152 970.75 7.70026690e-01 2.22796526e-01 8.01610501e-01 0.28164492 0.30716893 971.00 1.10508023e+00 2.37816054e-01 1.13037993e+00 0.21196973 0.44153228 971.25 1.12375088e+00 2.95690904e-01 1.16200222e+00 0.25729624 0.46428790 971.50 8.13677452e-01 3.16800098e-01 8.73174266e-01 0.37128619 0.39494288 971.75 5.79067339e-01 3.61432020e-01 6.82606833e-01 0.55799672 0.28483498 972.00 4.51240630e-01 3.35674527e-01 5.62401541e-01 0.63958085 0.24579980 972.25 4.40820322e-01 2.44865176e-01 5.04263334e-01 0.50703783 0.25718076 972.50 4.96110795e-01 1.71605126e-01 5.24951655e-01 0.33301832 0.37086862 972.75 5.57154023e-01 1.83535773e-01 5.86605477e-01 0.31822135 0.46272723 973.00 6.17967758e-01 3.60244009e-01 7.15304058e-01 0.52778803 0.48043734 973.25 4.82118458e-01 3.27697662e-01 5.82944221e-01 0.59697396 0.36746609 973.50 5.17221723e-01 2.78071095e-01 5.87232360e-01 0.49329228 0.34226555 973.75 5.60001059e-01 2.95205913e-01 6.33046378e-01 0.48513285 0.34443724 974.00 4.54633180e-01 1.87557311e-01 4.91801864e-01 0.39127529 0.29607167 974.25 5.28990547e-01 1.25814791e-01 5.43746596e-01 0.23350105 0.30290582 974.50 5.48721071e-01 3.96929352e-01 6.77235353e-01 0.62624014 0.28142841 974.75 6.49257890e-01 4.52536987e-01 7.91407312e-01 0.60871410 0.40382412 975.00 7.18573156e-01 3.83475869e-01 8.14494397e-01 0.49021391 0.55044654 975.25 7.28151864e-01 3.65370065e-01 8.14678109e-01 0.46506843 0.49196986 975.50 6.56427110e-01 2.15568642e-01 6.90917065e-01 0.31730122 0.33936855 975.75 5.95842204e-01 2.43466871e-01 6.43664548e-01 0.38790638 0.27316472 976.00 7.39894540e-01 2.49623034e-01 7.80868484e-01 0.32538499 0.36485305 976.25 8.01020894e-01 2.24891475e-01 8.31991976e-01 0.27370967 0.45159808 976.50 7.92698890e-01 -4.59217922e-02 7.94027922e-01 -0.05786627 0.39683839 976.75 8.31484742e-01 -8.68010412e-02 8.36003168e-01 -0.10401607 0.39147850 977.00 8.90313861e-01 -1.87000831e-01 9.09740667e-01 -0.20702976 0.47326599 977.25 9.12099422e-01 -2.05644039e-01 9.34994559e-01 -0.22175443 0.53123944 977.50 6.98005138e-01 -1.73997985e-01 7.19365325e-01 -0.24429991 0.40395166 977.75 7.48448084e-01 -1.70070615e-01 7.67527556e-01 -0.22343693 0.42071462 978.00 9.36569660e-01 -2.66922986e-01 9.73863752e-01 -0.27763978 0.51014878 978.25 8.02237210e-01 -3.33337682e-01 8.68733878e-01 -0.39380526 0.42627642 978.50 7.51463411e-01 -1.73347602e-01 7.71198191e-01 -0.22671416 0.23888636 978.75 8.35086130e-01 -2.53404614e-01 8.72687082e-01 -0.29461643 0.34993943 979.00 6.60838661e-01 -2.62854633e-01 7.11196382e-01 -0.37857313 0.26880652 979.25 5.20025446e-01 -4.07442971e-01 6.60633211e-01 -0.66460229 0.28827276 979.50 7.32284516e-01 -5.66967577e-01 9.26117080e-01 -0.65883816 0.35076994 979.75 8.36660715e-01 -8.07106242e-01 1.16250662e+00 -0.76742038 0.38789521 980.00 5.92037774e-01 -8.57801383e-01 1.04227249e+00 -0.96669109 0.36405710 980.25 5.05606818e-01 -3.77888637e-01 6.31219515e-01 -0.64183262 0.18565424 980.50 3.53629939e-01 -5.26357385e-02 3.57525740e-01 -0.14775932 0.06825642 980.75 2.40425916e-01 -4.63994371e-02 2.44862265e-01 -0.19064473 0.02765968 981.00 2.88263485e-01 -3.82527200e-02 2.90790487e-01 -0.13192974 0.03640879 981.25 2.25414729e-01 7.25518162e-03 2.25531457e-01 0.03217482 0.03091898 981.50 2.02456127e-01 -6.02306099e-02 2.11225495e-01 -0.28916124 0.02840806 981.75 3.71915460e-01 6.65526185e-02 3.77823187e-01 0.17707140 0.07290258 982.00 4.39145352e-01 1.90952285e-01 4.78864715e-01 0.41016473 0.12225965 982.25 5.85589851e-01 4.09343453e-01 7.14477106e-01 0.61007303 0.16380613 982.50 5.44518376e-01 2.86888600e-01 6.15471633e-01 0.48490924 0.12032941 982.75 4.85873566e-01 3.50077882e-01 5.98855279e-01 0.62436037 0.14748812 983.00 5.74911061e-01 2.36161237e-01 6.21526233e-01 0.38976372 0.15830558 983.25 3.08972223e-01 2.04970114e-01 3.70778347e-01 0.58573303 0.09263648 983.50 1.31714450e-02 3.07819688e-01 3.08101359e-01 1.52803293 0.07593134 983.75 -1.35014562e-01 4.41418903e-01 4.61605438e-01 1.86762507 0.18626751 984.00 -1.40343409e-01 4.98839346e-01 5.18205524e-01 1.84504708 0.24346991 984.25 -3.75212370e-01 4.68548751e-01 6.00268486e-01 2.24602297 0.37358879 984.50 -2.78551271e-01 5.73943494e-01 6.37967041e-01 2.02263819 0.32951157 984.75 -3.51793803e-01 8.20526676e-01 8.92761394e-01 1.97583175 0.58433222 985.00 -3.86959695e-01 9.05121021e-01 9.84368766e-01 1.97480170 0.63988297 985.25 -2.81410157e-01 1.02360244e+00 1.06158073e+00 1.83908941 0.57397919 985.50 -1.87652449e-01 1.02376065e+00 1.04081665e+00 1.75208113 0.46278189 985.75 2.17877899e-01 1.01561482e+00 1.03872241e+00 1.35947128 0.39837908 986.00 3.33542305e-01 1.05746766e+00 1.10882295e+00 1.26525703 0.39222813 986.25 4.50900677e-01 1.20126151e+00 1.28309806e+00 1.21171361 0.49434256 986.50 5.01184435e-01 1.09781982e+00 1.20681158e+00 1.14252779 0.51382772 986.75 5.00639382e-01 1.20956270e+00 1.30907666e+00 1.17836394 0.54578593 987.00 6.46332599e-01 1.16165204e+00 1.32935371e+00 1.06305974 0.50425555 987.25 9.03049652e-01 8.40697487e-01 1.23380344e+00 0.74965582 0.43668267 987.50 1.03892528e+00 7.65008556e-01 1.29019527e+00 0.63470517 0.45730972 987.75 1.07519138e+00 5.22223707e-01 1.19530503e+00 0.45214475 0.41512638 988.00 8.86613001e-01 6.37444263e-02 8.88901550e-01 0.07177306 0.25539415 988.25 9.34354125e-01 -6.09111489e-02 9.36337438e-01 -0.06509853 0.17824047 988.50 9.36344617e-01 -2.24357331e-01 9.62848614e-01 -0.23517598 0.17616008 988.75 9.35752023e-01 -5.66739263e-01 1.09399508e+00 -0.54456438 0.25283101 989.00 5.29180844e-01 -6.60710090e-01 8.46504689e-01 -0.89549013 0.15574378 989.25 2.34496176e-01 -6.55386999e-01 6.96075121e-01 -1.22719145 0.14072606 989.50 1.64035068e-01 -8.35575147e-01 8.51524122e-01 -1.37694753 0.17539090 989.75 -1.00968473e-01 -1.10021464e+00 1.10483795e+00 -1.66231160 0.28588704 990.00 -3.48208123e-01 -1.08278729e+00 1.13739932e+00 -1.88193636 0.34017374 990.25 -5.36497193e-01 -5.79067993e-01 7.89397859e-01 -2.31805225 0.23799922 990.50 -4.68112179e-01 -4.79997890e-01 6.70467737e-01 -2.34365893 0.24343513 990.75 -2.97363585e-01 -5.55272592e-01 6.29883127e-01 -2.06246014 0.24829507 991.00 -1.91391948e-01 -5.34428074e-01 5.67665610e-01 -1.91469086 0.21009894 991.25 1.20165004e-01 -5.30210814e-01 5.43657186e-01 -1.34792500 0.20293169 991.50 2.69094861e-02 -4.50310569e-01 4.51113876e-01 -1.51110969 0.14921870 991.75 -1.57900873e-01 -3.76468980e-01 4.08242059e-01 -1.96793628 0.11590918 992.00 -4.28307719e-02 -4.26843144e-01 4.28986649e-01 -1.67080469 0.13746778 992.25 1.50168643e-01 -4.06461645e-01 4.33314771e-01 -1.21689726 0.19557063 992.50 2.62341627e-01 -5.26448670e-01 5.88193277e-01 -1.10849099 0.40642132 992.75 2.06190257e-01 -6.66512399e-01 6.97677002e-01 -1.27077742 0.43925423 993.00 1.98322360e-01 -4.99089639e-01 5.37049557e-01 -1.19256079 0.32846678 993.25 2.15568022e-01 -5.28755070e-01 5.71009191e-01 -1.18367848 0.40622653 993.50 2.63523148e-01 -4.79096514e-01 5.46788734e-01 -1.06792096 0.40039036 993.75 2.27933828e-01 -5.24840770e-01 5.72198972e-01 -1.16108218 0.45376208 994.00 1.26713564e-01 -4.09364676e-01 4.28527438e-01 -1.27061301 0.28488375 994.25 1.32570981e-01 -3.15723605e-01 3.42427306e-01 -1.17325701 0.19668735 994.50 -1.28872481e-02 -3.60751674e-01 3.60981788e-01 -1.60650446 0.19852479 994.75 -4.67761117e-02 -3.34334076e-01 3.37590401e-01 -1.70980233 0.21109671 995.00 5.80517926e-02 -2.14267071e-01 2.21991866e-01 -1.30621608 0.12899550 995.25 1.58777106e-01 -2.09598721e-01 2.62948271e-01 -0.92249406 0.14576408 995.50 1.66339617e-01 9.48614655e-02 1.91487769e-01 0.51828578 0.07338975 995.75 1.80085663e-01 1.38212274e-01 2.27009865e-01 0.65459522 0.12772048 996.00 2.37868826e-01 1.48225378e-01 2.80271906e-01 0.55726006 0.15533454 996.25 3.01346941e-01 1.00760911e-01 3.17746345e-01 0.32268187 0.21772291 996.50 3.68756397e-01 6.02278481e-02 3.73642441e-01 0.16189745 0.28318193 996.75 2.95999276e-01 5.83977274e-02 3.01704932e-01 0.19478854 0.13588445 997.00 1.62041658e-01 2.06728398e-01 2.62667336e-01 0.90598800 0.09351542 997.25 1.52653788e-01 1.96144871e-01 2.48547760e-01 0.90944616 0.07676528 997.50 3.08009612e-01 2.76040615e-01 4.13604089e-01 0.73071601 0.20274651 997.75 4.27729153e-01 4.81395761e-01 6.43967474e-01 0.84436080 0.32948299 998.00 7.69789437e-01 7.37913107e-01 1.06634494e+00 0.76425899 0.45692393 998.25 7.39099664e-01 6.36559093e-01 9.75436206e-01 0.71099650 0.47899478 998.50 5.67751255e-01 6.11351057e-01 8.34321042e-01 0.82235844 0.38463940 998.75 8.90252583e-01 5.93817149e-01 1.07012544e+00 0.58824786 0.49544132 999.00 9.22357230e-01 5.37930403e-01 1.06776026e+00 0.52798440 0.53031854 999.25 1.06493618e+00 3.36865982e-01 1.11694572e+00 0.30636580 0.54330318 999.50 1.25411501e+00 3.15562289e-01 1.29320688e+00 0.24650419 0.67234696 999.75 1.24994851e+00 2.24111960e-01 1.26988088e+00 0.17741187 0.60669632 1000.00 1.27955713e+00 0.00000000e+00 1.27955713e+00 0.00000000 0.62539692