========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0059 Injection acquisition : SIG0060 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -1.94994745e-02 0.00000000e+00 1.94994745e-02 3.14159265 0.60318473 0.25 -1.92882125e-02 -1.76965653e-03 1.93692237e-02 -3.05010071 0.55389057 0.50 1.14013587e-02 -2.89768581e-02 3.11391922e-02 -1.19593685 0.23020057 0.75 5.89601866e-03 -1.83310038e-02 1.92558753e-02 -1.25960472 0.10202471 1.00 8.74701750e-03 -1.43945550e-02 1.68437979e-02 -1.02476238 0.07894876 1.25 6.74485252e-03 -1.03430955e-02 1.23479820e-02 -0.99293811 0.04575192 1.50 7.49788959e-03 -7.01736224e-03 1.02694557e-02 -0.75230525 0.02583598 1.75 5.30336020e-03 -1.25295487e-02 1.36057054e-02 -1.17039340 0.05237915 2.00 6.91562949e-04 -1.19051423e-02 1.19252116e-02 -1.51277210 0.03620885 2.25 6.97572642e-03 -1.21148482e-02 1.39796390e-02 -1.04836123 0.05325173 2.50 1.30687319e-02 -7.94846376e-03 1.52960723e-02 -0.54643052 0.05156664 2.75 7.27399075e-03 -1.65397265e-02 1.80685776e-02 -1.15646619 0.06412033 3.00 9.04090775e-03 -2.35392442e-02 2.52157497e-02 -1.20409064 0.10319570 3.25 4.12382023e-03 -1.28967267e-02 1.35399945e-02 -1.26131371 0.03000576 3.50 1.75027602e-03 -1.20614740e-02 1.21878063e-02 -1.42668929 0.02622776 3.75 1.12596359e-02 -1.94037565e-02 2.24340181e-02 -1.04500211 0.06444756 4.00 1.11286796e-02 -1.98576520e-02 2.27634324e-02 -1.05998625 0.05826703 4.25 9.21550325e-03 -2.52377548e-02 2.68676342e-02 -1.22069131 0.08135401 4.50 1.10986995e-02 -2.30644150e-02 2.55958663e-02 -1.12229789 0.07225438 4.75 7.86475418e-03 -2.24487580e-02 2.37865738e-02 -1.23381641 0.05550367 5.00 4.31599460e-03 -2.55634432e-02 2.59252279e-02 -1.40353902 0.06597027 5.25 -4.56778770e-03 -2.90516240e-02 2.94085284e-02 -1.72674960 0.06745907 5.50 -1.46129621e-03 -2.55325274e-02 2.55743102e-02 -1.62796669 0.04828744 5.75 -7.05867390e-03 -2.10702346e-02 2.22211535e-02 -1.89405233 0.03540316 6.00 -4.25946594e-03 -2.66479498e-02 2.69862239e-02 -1.72929769 0.05026551 6.25 3.58572211e-03 -2.90646499e-02 2.92850009e-02 -1.44804603 0.05726286 6.50 3.48288726e-04 -3.39440912e-02 3.39458780e-02 -1.56053603 0.07547242 6.75 1.67922726e-02 -3.19331221e-02 3.60791450e-02 -1.08667732 0.06840394 7.00 8.18647930e-03 -2.93744670e-02 3.04938971e-02 -1.29899935 0.04943545 7.25 -1.38527964e-03 -4.73047633e-02 4.73250423e-02 -1.60007211 0.11411443 7.50 5.93464532e-03 -4.28945831e-02 4.33031786e-02 -1.43331492 0.08888634 7.75 6.59292055e-03 -1.41622934e-02 1.56216886e-02 -1.13510598 0.01050626 8.00 2.15946442e-03 -2.55880637e-02 2.56790244e-02 -1.48660240 0.02815617 8.25 -1.98574094e-03 -3.86276123e-02 3.86786194e-02 -1.62215841 0.05628771 8.50 -9.36719827e-04 -3.85187419e-02 3.85301300e-02 -1.59511008 0.05499621 8.75 -1.27793299e-02 -5.06765202e-02 5.22629981e-02 -1.81782060 0.10523125 9.00 2.79714464e-03 -4.81423648e-02 4.82235555e-02 -1.51276005 0.08406193 9.25 7.82300894e-03 -3.47958478e-02 3.56644150e-02 -1.34964757 0.03827804 9.50 5.42323338e-03 -4.34267858e-02 4.37641084e-02 -1.44655730 0.05662129 9.75 1.62729671e-02 -6.80113488e-02 6.99310591e-02 -1.33594321 0.11815348 10.00 6.74133048e-03 -4.98827536e-02 5.03362160e-02 -1.43646666 0.06576580 10.25 -8.86522328e-03 -5.66583763e-02 5.73477444e-02 -1.72600587 0.08205039 10.50 6.14967724e-03 -5.22353406e-02 5.25960962e-02 -1.45360557 0.07432669 10.75 -2.49204584e-03 -3.91218579e-02 3.92011487e-02 -1.63440996 0.04068659 11.00 6.87253721e-03 -5.02201390e-02 5.06882051e-02 -1.43479290 0.06518512 11.25 3.58151086e-02 -5.55739858e-02 6.61149749e-02 -0.99832682 0.09281657 11.50 1.72684913e-02 -5.89021155e-02 6.13812675e-02 -1.28561483 0.08165805 11.75 1.37097920e-02 -6.46175135e-02 6.60558963e-02 -1.36172827 0.08535837 12.00 1.74387051e-02 -5.78003178e-02 6.03737126e-02 -1.27777509 0.07109605 12.25 8.05396162e-03 -6.26315962e-02 6.31473130e-02 -1.44290555 0.07427999 12.50 1.78379489e-02 -6.67863318e-02 6.91274658e-02 -1.30979892 0.08953908 12.75 3.78338374e-02 -6.24621540e-02 7.30268439e-02 -1.02619021 0.08479737 13.00 1.16259977e-02 -4.75803090e-02 4.89800942e-02 -1.33114731 0.03383592 13.25 2.23755022e-02 -4.85118735e-02 5.34234497e-02 -1.13863657 0.03318925 13.50 4.29753912e-02 -4.94938768e-02 6.55479069e-02 -0.85577528 0.04031708 13.75 7.16627823e-02 -4.66800191e-02 8.55253095e-02 -0.57734783 0.05252279 14.00 5.30748888e-02 -4.16404703e-02 6.74601556e-02 -0.66525556 0.02555750 14.25 4.47061276e-02 -3.26975171e-02 5.53874126e-02 -0.63148251 0.01371251 14.50 3.86276916e-02 -7.39727868e-02 8.34510141e-02 -1.08955639 0.05112912 14.75 5.31051021e-02 -1.18538775e-01 1.29890696e-01 -1.14960874 0.14194886 15.00 1.05785035e-01 -8.26900642e-02 1.34268836e-01 -0.66347007 0.12769916 15.25 1.21222271e-01 -7.60181796e-02 1.43085998e-01 -0.56010619 0.13962574 15.50 7.71190565e-02 -7.36617749e-02 1.06646172e-01 -0.76247299 0.08069900 15.75 6.34362104e-02 -9.10043314e-02 1.10932146e-01 -0.96204084 0.09662972 16.00 1.49472020e-02 -8.30263570e-02 8.43610977e-02 -1.39267472 0.05527640 16.25 9.89258055e-03 -1.01987239e-01 1.02465897e-01 -1.47410061 0.08516147 16.50 8.89782248e-02 -1.00437214e-01 1.34181811e-01 -0.84582112 0.12466284 16.75 7.14175149e-02 -8.92204513e-02 1.14283640e-01 -0.89577419 0.09491655 17.00 6.39635485e-02 -4.19428398e-02 7.64888054e-02 -0.58039304 0.03582293 17.25 4.23130357e-02 -5.01606776e-02 6.56238263e-02 -0.87005880 0.02932817 17.50 2.31281240e-02 -1.60293186e-01 1.61953128e-01 -1.42749890 0.14815883 17.75 3.16689026e-02 -1.48548977e-01 1.51887188e-01 -1.36075247 0.14303944 18.00 1.14189108e-01 -9.67489815e-02 1.49664685e-01 -0.70290690 0.13984718 18.25 9.33517806e-02 -9.51939185e-02 1.33328306e-01 -0.79516810 0.10900127 18.50 1.08967651e-01 -7.73089300e-02 1.33606211e-01 -0.61705130 0.10764899 18.75 7.02992528e-02 -7.99589843e-02 1.06467949e-01 -0.84959735 0.07574474 19.00 4.29753681e-02 -2.01820610e-02 4.74783935e-02 -0.43904900 0.01467347 19.25 5.60329868e-02 -6.22227641e-02 8.37339118e-02 -0.83769273 0.04437982 19.50 9.39970945e-02 -5.32010061e-02 1.08008337e-01 -0.51503336 0.06771450 19.75 7.44582113e-02 -7.79700712e-02 1.07811675e-01 -0.80843351 0.06783246 20.00 8.71758801e-02 -2.64534038e-02 9.11011342e-02 -0.29461769 0.04328758 20.25 4.63704173e-02 -6.69038791e-02 8.14023626e-02 -0.96472294 0.03470713 20.50 5.62774396e-02 -7.04747745e-02 9.01878265e-02 -0.89694182 0.03633996 20.75 5.66457878e-02 -6.07602305e-02 8.30695545e-02 -0.82042839 0.03238416 21.00 1.54025837e-01 -6.63462275e-02 1.67707425e-01 -0.40672865 0.09250190 21.25 6.46392705e-02 -5.44737187e-02 8.45317770e-02 -0.70026069 0.03472344 21.50 5.79487865e-02 -6.50183684e-02 8.70944894e-02 -0.84282657 0.04160684 21.75 1.10380479e-01 -7.73470306e-02 1.34782837e-01 -0.61121644 0.06816208 22.00 1.74575567e-01 1.09546912e-02 1.74918935e-01 0.06266826 0.08084035 22.25 1.56738167e-01 -9.44944710e-02 1.83019283e-01 -0.54253523 0.10431550 22.50 1.36083727e-01 -1.27316072e-01 1.86354938e-01 -0.75212396 0.09639247 22.75 1.29234699e-01 -3.73069000e-02 1.34511754e-01 -0.28103530 0.07152148 23.00 1.74660874e-01 2.61729772e-02 1.76611001e-01 0.14874350 0.12496010 23.25 9.40635625e-02 -6.47744306e-02 1.14208934e-01 -0.60305022 0.05199070 23.50 8.41893812e-02 -8.16615066e-02 1.17287909e-01 -0.77015749 0.04176601 23.75 2.38821890e-01 -1.47663353e-01 2.80785258e-01 -0.55376615 0.19072055 24.00 3.10334525e-01 -1.65875747e-01 3.51883902e-01 -0.49087006 0.25201361 24.25 1.79203748e-01 -1.12639221e-01 2.11663831e-01 -0.56115087 0.11356047 24.50 2.94287597e-01 -1.31334739e-01 3.22263872e-01 -0.41975627 0.21733932 24.75 2.34061542e-01 -8.35764595e-02 2.48535370e-01 -0.34295972 0.17682268 25.00 1.78285322e-01 -1.03333439e-01 2.06066629e-01 -0.52528135 0.13826129 25.25 1.54765649e-01 -1.23840564e-01 1.98214256e-01 -0.67485143 0.11026581 25.50 1.50610681e-01 -1.52964272e-01 2.14666359e-01 -0.79315093 0.12107216 25.75 1.99065887e-01 -4.54624528e-02 2.04191239e-01 -0.22452821 0.09985253 26.00 2.04817524e-01 -2.99887087e-02 2.07001306e-01 -0.14538368 0.09352414 26.25 1.63069439e-01 -1.00550171e-01 1.91577605e-01 -0.55254296 0.11683038 26.50 1.19494267e-01 -1.22567579e-01 1.71177368e-01 -0.79809387 0.10235238 26.75 3.06346340e-02 -1.02554968e-01 1.07032716e-01 -1.28051951 0.04687651 27.00 1.18393096e-02 -1.02036848e-01 1.02721407e-01 -1.45528311 0.04446014 27.25 5.51637641e-02 -1.28305330e-01 1.39661371e-01 -1.16474778 0.07808754 27.50 8.15734310e-02 -1.55844582e-01 1.75902696e-01 -1.08858239 0.11561468 27.75 2.57339882e-02 -7.55655797e-02 7.98272822e-02 -1.24256335 0.01900075 28.00 5.20091913e-02 -8.64794576e-02 1.00914085e-01 -1.02934427 0.03474194 28.25 3.90649306e-02 -1.42318462e-01 1.47582565e-01 -1.30290474 0.08158424 28.50 4.45248526e-02 -1.33194738e-01 1.40439669e-01 -1.24819053 0.07662473 28.75 5.43830105e-02 -1.39283254e-01 1.49523699e-01 -1.19855057 0.09450189 29.00 4.25825243e-02 -1.27919360e-01 1.34820747e-01 -1.24944871 0.07593720 29.25 8.70002260e-02 -4.54470266e-02 9.81553439e-02 -0.48138952 0.03521807 29.50 6.68334921e-02 -9.35538130e-02 1.14974047e-01 -0.95048074 0.05040715 29.75 1.30697948e-01 -6.77778309e-02 1.47226994e-01 -0.47840383 0.07717982 30.00 7.23019350e-02 -1.01507616e-01 1.24624901e-01 -0.95187562 0.05261237 30.25 3.83384128e-02 -1.41390630e-01 1.46496226e-01 -1.30601068 0.06959987 30.50 4.41211475e-02 -1.15887663e-01 1.24002525e-01 -1.20701733 0.05044558 30.75 5.89600860e-02 6.26316828e-03 5.92918124e-02 0.10583038 0.01011397 31.00 9.54624099e-02 -9.46609360e-02 1.34438702e-01 -0.78118264 0.04766671 31.25 1.61156618e-01 -6.54747297e-02 1.73949406e-01 -0.38590852 0.06411970 31.50 1.26477306e-01 -7.80736378e-02 1.48633784e-01 -0.55303847 0.06006240 31.75 1.21540243e-01 -8.11604157e-02 1.46147336e-01 -0.58876314 0.05697933 32.00 1.93150490e-01 -1.24580011e-01 2.29841882e-01 -0.57284473 0.12890701 32.25 3.43418934e-01 -9.86043799e-02 3.57294540e-01 -0.27960401 0.24990537 32.50 3.26391610e-01 -7.22672512e-02 3.34296334e-01 -0.21789740 0.24252857 32.75 3.97893587e-01 4.51671817e-03 3.97919222e-01 0.01135109 0.25582041 33.00 2.49035295e-01 -7.26591391e-02 2.59418443e-01 -0.28388235 0.14504045 33.25 1.72541665e-01 -1.45585005e-01 2.25755664e-01 -0.70086448 0.11996142 33.50 1.84071191e-01 -1.12020077e-01 2.15477844e-01 -0.54669665 0.12213618 33.75 1.87425219e-01 -9.51326020e-02 2.10186642e-01 -0.46969027 0.12653508 34.00 2.22634546e-01 -2.11189056e-01 3.06866352e-01 -0.75902146 0.19257082 34.25 3.31527446e-01 -1.36934402e-01 3.58694129e-01 -0.39169776 0.21032267 34.50 2.38625517e-01 -8.92808880e-02 2.54780718e-01 -0.35802214 0.13161466 34.75 2.91546591e-01 -7.49907764e-02 3.01036595e-01 -0.25175963 0.15138340 35.00 3.51983359e-01 -1.07718292e-01 3.68097155e-01 -0.29698182 0.26143403 35.25 3.22199168e-01 -1.58244396e-01 3.58961826e-01 -0.45653326 0.24234501 35.50 2.72121255e-01 -1.64868463e-01 3.18169117e-01 -0.54472009 0.20338435 35.75 2.85733634e-01 -1.04614855e-01 3.04282726e-01 -0.35096918 0.18452087 36.00 2.32552689e-01 -1.63842234e-01 2.84473252e-01 -0.61376519 0.20770550 36.25 4.19967651e-01 -9.59608416e-02 4.30791494e-01 -0.22463929 0.35629629 36.50 6.45276873e-01 -1.04250186e-01 6.53643897e-01 -0.16017483 0.66404183 36.75 5.91171875e-01 -1.48408000e-01 6.09515480e-01 -0.24595759 0.52657293 37.00 4.70637789e-01 -5.58217256e-02 4.73936698e-01 -0.11805713 0.36161774 37.25 4.48840763e-01 -6.79125086e-02 4.53949490e-01 -0.15016742 0.34588718 37.50 3.95213469e-01 -7.52992183e-02 4.02322828e-01 -0.18827147 0.24359560 37.75 3.68627956e-01 -1.16321671e-01 3.86545342e-01 -0.30566386 0.25622226 38.00 4.33158851e-01 -2.80205211e-02 4.34064212e-01 -0.06459878 0.39920838 38.25 3.45927829e-01 -4.35051496e-02 3.48652780e-01 -0.12510683 0.25829232 38.50 3.03393384e-01 -5.04736558e-02 3.07563222e-01 -0.16485392 0.20059199 38.75 3.70300620e-01 -5.06929419e-02 3.73754363e-01 -0.13605103 0.24012937 39.00 4.16382974e-01 -2.42507137e-02 4.17088573e-01 -0.05817565 0.26790285 39.25 3.38414023e-01 -1.21875028e-02 3.38633409e-01 -0.03599803 0.21014009 39.50 3.46545164e-01 1.15121848e-02 3.46736328e-01 0.03320766 0.21058844 39.75 2.46450351e-01 -4.37501274e-02 2.50303514e-01 -0.17569076 0.09809483 40.00 2.46742326e-01 -1.70328580e-01 2.99822615e-01 -0.60419265 0.14135591 40.25 2.20819276e-01 -1.78668977e-01 2.84048862e-01 -0.68027637 0.12592043 40.50 2.62212125e-01 -2.06081494e-01 3.33503794e-01 -0.66610523 0.16643833 40.75 2.34645291e-01 -1.79816403e-01 2.95621974e-01 -0.65387247 0.13016075 41.00 2.70345079e-01 -4.24471808e-02 2.73657131e-01 -0.15573963 0.10241152 41.25 2.15067319e-01 -7.95532427e-02 2.29309115e-01 -0.35429131 0.07653989 41.50 2.00997600e-01 -1.42372290e-01 2.46312615e-01 -0.61629359 0.10006896 41.75 1.69882965e-01 -1.90717036e-01 2.55407928e-01 -0.84311013 0.10021320 42.00 1.56221931e-01 -1.72721140e-01 2.32890283e-01 -0.83551441 0.07486597 42.25 1.63163726e-01 -1.23539445e-01 2.04656775e-01 -0.64806154 0.05406179 42.50 2.76572833e-01 -8.83697719e-02 2.90347634e-01 -0.30926491 0.09260081 42.75 2.00226534e-01 -1.70662483e-01 2.63090000e-01 -0.70585503 0.08784760 43.00 3.24525150e-01 -1.67351000e-01 3.65134127e-01 -0.47611246 0.17371896 43.25 2.74103359e-01 -1.21818035e-01 2.99953805e-01 -0.41820702 0.11193890 43.50 2.68851763e-01 -1.37523249e-01 3.01983301e-01 -0.47282165 0.11526584 43.75 2.23702260e-01 -1.89767373e-01 2.93350230e-01 -0.70350824 0.12176067 44.00 1.67719720e-01 -1.30918207e-01 2.12766260e-01 -0.66278513 0.08083459 44.25 1.65325303e-01 -1.85913838e-01 2.48789894e-01 -0.84394802 0.09069508 44.50 2.29451575e-01 -2.43760609e-01 3.34764484e-01 -0.81562705 0.13579581 44.75 2.74359202e-01 -9.18265306e-02 2.89318308e-01 -0.32297515 0.11608993 45.00 3.71353445e-01 -1.31915769e-01 3.94087745e-01 -0.34132617 0.20275385 45.25 3.94751962e-01 -1.28866748e-02 3.94962248e-01 -0.03263340 0.19186610 45.50 3.95416359e-01 -1.07991331e-02 3.95563798e-01 -0.02730400 0.20143553 45.75 1.71160812e-01 -1.96929607e-01 2.60916258e-01 -0.85529083 0.08140488 46.00 1.31374183e-01 -1.74550050e-01 2.18464862e-01 -0.92560471 0.06410465 46.25 6.88655778e-02 -1.19583925e-01 1.37995590e-01 -1.04830355 0.02555113 46.50 9.70586372e-02 -7.38212346e-02 1.21942420e-01 -0.65024045 0.02283606 46.75 1.79807728e-01 -1.23537531e-01 2.18156688e-01 -0.60198410 0.06713487 47.00 1.54686265e-01 -8.21367044e-02 1.75140740e-01 -0.48813037 0.04193483 47.25 3.44439734e-01 -1.18937338e-01 3.64396516e-01 -0.33248758 0.13982760 47.50 3.34635915e-01 -1.20211831e-01 3.55572889e-01 -0.34487527 0.13540459 47.75 2.01403851e-01 4.82185142e-03 2.01461563e-01 0.02393664 0.06732835 48.00 1.92025896e-01 2.35428609e-02 1.93463721e-01 0.12199372 0.05143804 48.25 4.92289951e-01 1.86355213e-01 5.26381669e-01 0.36187732 0.19623016 48.50 3.93011733e-01 2.37097721e-01 4.58991886e-01 0.54283077 0.13355292 48.75 7.50009334e-01 3.06645448e-01 8.10274911e-01 0.38811705 0.21206766 49.00 7.00466158e-01 3.98461040e-01 8.05868500e-01 0.51720104 0.17971278 49.25 3.91409033e-01 8.55721764e-01 9.40989250e-01 1.14180379 0.16776691 49.50 4.57461371e-01 6.62744186e-01 8.05295450e-01 0.96664176 0.06315381 49.75 2.60356998e+00 -8.89154808e-01 2.75121299e+00 -0.32909473 0.18293865 50.00 2.24791825e+00 -2.13955339e+00 3.10335708e+00 -0.76070448 0.26215612 50.25 6.87834604e-01 -1.86569942e+00 1.98845436e+00 -1.21758336 0.29814728 50.50 2.85746999e-01 -8.77851188e-01 9.23186902e-01 -1.25610563 0.18972975 50.75 4.43633043e-01 -7.45230628e-01 8.67282518e-01 -1.03384260 0.37527780 51.00 3.62518707e-01 -5.43129676e-01 6.53000504e-01 -0.98224294 0.31576841 51.25 4.66981938e-01 -3.01910902e-01 5.56077623e-01 -0.57392152 0.33049763 51.50 5.46256769e-01 -3.43230477e-01 6.45138449e-01 -0.56099160 0.40901543 51.75 6.64970315e-01 -4.04584884e-01 7.78379373e-01 -0.54659169 0.53716758 52.00 6.05703947e-01 -3.17037533e-01 6.83659322e-01 -0.48220755 0.44691282 52.25 6.30411843e-01 -3.78696634e-01 7.35411608e-01 -0.54094365 0.50551334 52.50 6.31111881e-01 -3.98636853e-01 7.46467378e-01 -0.56336143 0.49347525 52.75 6.87645424e-01 -3.66313488e-01 7.79128873e-01 -0.48946952 0.53133771 53.00 6.31573749e-01 -2.02971941e-01 6.63387526e-01 -0.31094962 0.42792392 53.25 7.45961703e-01 -7.57719041e-02 7.49800136e-01 -0.10122893 0.40823159 53.50 5.84410615e-01 -2.67956876e-01 6.42912634e-01 -0.42990652 0.30278241 53.75 6.68895667e-01 -4.82365318e-01 8.24680370e-01 -0.62477137 0.46395760 54.00 6.78230399e-01 -3.60714282e-01 7.68187000e-01 -0.48879883 0.42947685 54.25 7.99090462e-01 -3.12105773e-01 8.57878535e-01 -0.37235617 0.51433240 54.50 7.86713819e-01 -4.62921963e-01 9.12806319e-01 -0.53186488 0.59736870 54.75 7.71924772e-01 -5.12582315e-01 9.26611290e-01 -0.58617599 0.66284159 55.00 6.91789115e-01 -3.88250474e-01 7.93291000e-01 -0.51142163 0.44690999 55.25 8.31382637e-01 -3.28614441e-01 8.93971219e-01 -0.37641573 0.54184641 55.50 8.58274709e-01 -4.33541877e-01 9.61558129e-01 -0.46774464 0.41403443 55.75 8.32880231e-01 -6.73008906e-01 1.07080832e+00 -0.67963027 0.43803152 56.00 7.45035841e-01 -5.47581731e-01 9.24621088e-01 -0.63381470 0.59442875 56.25 7.69126303e-01 -6.30250547e-01 9.94369660e-01 -0.68648091 0.63273024 56.50 6.67864784e-01 -7.26596324e-01 9.86907082e-01 -0.82749102 0.53173037 56.75 6.86895706e-01 -7.99138041e-01 1.05377764e+00 -0.86078650 0.56858262 57.00 6.71385799e-01 -7.40011846e-01 9.99187882e-01 -0.83398266 0.58005007 57.25 6.63813625e-01 -7.82138493e-01 1.02586020e+00 -0.86704804 0.53155988 57.50 3.51569704e-01 -9.59881283e-01 1.02223937e+00 -1.21970676 0.34859561 57.75 2.65548795e-02 -8.25460206e-01 8.25887228e-01 -1.53863763 0.22595823 58.00 -7.96656255e-01 -3.06000346e-01 8.53403422e-01 -2.77486275 0.17351351 58.25 -9.14306683e-01 1.70155069e-01 9.30005085e-01 2.95759475 0.16363729 58.50 -1.99101123e-03 1.30469062e+00 1.30469214e+00 1.57232237 0.32859450 58.75 6.99897720e-01 1.33054927e+00 1.50340221e+00 1.08654876 0.40449905 59.00 2.16183608e+00 1.12043674e+00 2.43493608e+00 0.47816456 0.70957748 59.25 2.35399818e+00 4.30265986e-01 2.39299734e+00 0.18078529 0.75000473 59.50 1.83121292e+00 -4.13098569e-01 1.87722966e+00 -0.22187347 0.79098782 59.75 1.53400333e+00 -3.33784184e-01 1.56989748e+00 -0.21425065 0.79260743 60.00 1.31159519e+00 -2.72512036e-01 1.33960619e+00 -0.20485682 0.85385095 60.25 1.14698262e+00 -2.77518588e-01 1.18007868e+00 -0.23739302 0.79464289 60.50 1.01248732e+00 -2.75094682e-01 1.04919381e+00 -0.26529737 0.81268738 60.75 9.77591723e-01 -2.26892575e-01 1.00357651e+00 -0.22805569 0.78251539 61.00 9.52406799e-01 -1.17004860e-01 9.59567011e-01 -0.12223926 0.76260505 61.25 9.07198855e-01 -6.44172034e-02 9.09483006e-01 -0.07088773 0.68010683 61.50 1.03339456e+00 -1.47353875e-01 1.04384744e+00 -0.14163728 0.77755553 61.75 9.97290798e-01 -1.77023899e-01 1.01288025e+00 -0.17567499 0.75034558 62.00 9.01606055e-01 -1.91879553e-01 9.21797831e-01 -0.20969128 0.71711574 62.25 8.80667338e-01 -1.97628448e-01 9.02569645e-01 -0.22075052 0.68679205 62.50 9.53623540e-01 -1.33389878e-01 9.62907429e-01 -0.13897518 0.69946892 62.75 8.89972490e-01 -2.13661956e-01 9.15260872e-01 -0.23561782 0.66268975 63.00 9.35557384e-01 -3.24884489e-01 9.90362333e-01 -0.33423446 0.74561655 63.25 9.54916427e-01 -1.91550158e-01 9.73938830e-01 -0.19796630 0.69770157 63.50 1.10798375e+00 -1.26921772e-01 1.11522963e+00 -0.11405487 0.80421073 63.75 1.09757943e+00 -2.04243603e-01 1.11642109e+00 -0.18398113 0.81307322 64.00 1.08818190e+00 -2.46128572e-01 1.11566981e+00 -0.22244044 0.82609968 64.25 1.12356255e+00 -3.00246880e-01 1.16298796e+00 -0.26112597 0.78397244 64.50 1.17466986e+00 -3.10375476e-01 1.21498239e+00 -0.25832012 0.84675000 64.75 1.20811720e+00 -3.71191242e-01 1.26385526e+00 -0.29809273 0.79330016 65.00 1.25017077e+00 -4.01265654e-01 1.31298937e+00 -0.31058139 0.79225110 65.25 1.06151277e+00 -3.38467577e-01 1.11416770e+00 -0.30866304 0.62877707 65.50 1.09650778e+00 -3.99434708e-01 1.16699503e+00 -0.34933843 0.68327071 65.75 1.10680201e+00 -3.99923084e-01 1.17683863e+00 -0.34673434 0.74492665 66.00 1.14767960e+00 -4.02972454e-01 1.21636970e+00 -0.33767162 0.81564782 66.25 1.12456053e+00 -4.01318275e-01 1.19402377e+00 -0.34277906 0.78736872 66.50 1.08527771e+00 -4.48372902e-01 1.17425123e+00 -0.39178339 0.76655126 66.75 1.08328939e+00 -4.46071584e-01 1.17153564e+00 -0.39061592 0.82635122 67.00 1.05272903e+00 -3.78347536e-01 1.11865333e+00 -0.34502156 0.82781138 67.25 1.17375220e+00 -3.36577945e-01 1.22105649e+00 -0.27926049 0.73708622 67.50 1.29701020e+00 -3.77701987e-01 1.35088647e+00 -0.28337294 0.75167836 67.75 1.57323591e+00 -5.19259112e-01 1.65671400e+00 -0.31879987 0.77836020 68.00 1.86479569e+00 -5.87705198e-01 1.95521363e+00 -0.30530452 0.76615772 68.25 2.59151873e+00 -1.58977828e+00 3.04029017e+00 -0.55025367 0.71889320 68.50 2.10763209e+00 -2.25992358e+00 3.09020511e+00 -0.82025286 0.57034128 68.75 -4.79320944e-01 -1.88904633e+00 1.94890856e+00 -1.81928906 0.44362818 69.00 -3.00595232e-01 -1.00974621e+00 1.05353922e+00 -1.86013604 0.38829442 69.25 2.06283400e-01 -4.47511948e-01 4.92767475e-01 -1.13886868 0.44965102 69.50 3.28212432e-01 -3.16950146e-01 4.56268338e-01 -0.76794343 0.52705715 69.75 4.22175032e-01 -2.59080293e-01 4.95332571e-01 -0.55041751 0.70356442 70.00 5.21256581e-01 -2.36161876e-01 5.72259430e-01 -0.42539789 0.74498957 70.25 6.48445791e-01 -2.38263447e-01 6.90833855e-01 -0.35212431 0.85027179 70.50 7.14556586e-01 -2.43586718e-01 7.54934171e-01 -0.32853798 0.86068899 70.75 7.75001284e-01 -1.93008273e-01 7.98673390e-01 -0.24407730 0.86036158 71.00 8.64794173e-01 -2.43337268e-01 8.98377419e-01 -0.27428951 0.82373574 71.25 9.26552419e-01 -4.02640959e-01 1.01025696e+00 -0.40993860 0.82636752 71.50 7.67908992e-01 -4.56941982e-01 8.93577190e-01 -0.53676967 0.68726209 71.75 5.70539144e-01 -3.98292821e-01 6.95810381e-01 -0.60944900 0.68368511 72.00 5.76913021e-01 -3.42898373e-01 6.71124376e-01 -0.53626769 0.65451172 72.25 5.94597663e-01 -3.41318907e-01 6.85598262e-01 -0.52110754 0.78832683 72.50 6.40675002e-01 -3.15566700e-01 7.14175609e-01 -0.45767267 0.77362303 72.75 6.80378073e-01 -2.56924536e-01 7.27271985e-01 -0.36106589 0.82940873 73.00 7.27807553e-01 -2.15921075e-01 7.59161212e-01 -0.28840200 0.84460555 73.25 7.96981230e-01 -1.76205419e-01 8.16227561e-01 -0.21759075 0.88546175 73.50 8.41793941e-01 -1.33222024e-01 8.52270583e-01 -0.15695790 0.88287366 73.75 9.35973735e-01 -1.28803670e-01 9.44794802e-01 -0.13675565 0.92391360 74.00 1.04635976e+00 -1.46056084e-01 1.05650420e+00 -0.13868886 0.92521982 74.25 1.14072489e+00 -1.58459680e-01 1.15167823e+00 -0.13802810 0.93615487 74.50 1.22277500e+00 -1.87956181e-01 1.23713630e+00 -0.15251906 0.88267857 74.75 1.36140137e+00 -2.40590152e-01 1.38249677e+00 -0.17491642 0.88726221 75.00 1.40649380e+00 -3.34717711e-01 1.44577341e+00 -0.23363434 0.80844960 75.25 1.41816956e+00 -3.46517756e-01 1.45989022e+00 -0.23964602 0.69459596 75.50 1.25383463e+00 -6.37409306e-01 1.40655320e+00 -0.47031952 0.60811411 75.75 1.36336474e+00 -7.87728416e-01 1.57457279e+00 -0.52392296 0.66860418 76.00 1.46201470e+00 -1.01194970e+00 1.77806894e+00 -0.60544556 0.39738594 76.25 1.52325783e+00 -1.61862159e+00 2.22266738e+00 -0.81574130 0.40147014 76.50 1.58301621e+00 -6.79389160e-01 1.72264620e+00 -0.40540062 0.31634175 76.75 1.79007111e+00 -7.86286230e-01 1.95514721e+00 -0.41387718 0.48358181 77.00 1.63211719e+00 -9.62959653e-01 1.89501921e+00 -0.53303889 0.71768159 77.25 1.80053317e+00 -1.00463949e+00 2.06184874e+00 -0.50893992 0.77929760 77.50 2.27910572e+00 -1.64086290e+00 2.80833651e+00 -0.62399612 0.78038742 77.75 2.51920135e+00 -2.12065348e+00 3.29295409e+00 -0.69971186 0.56870098 78.00 3.20966183e+00 -7.91177499e+00 8.53803915e+00 -1.18540160 0.59361887 78.25 1.92385205e+00 -1.16603713e+01 1.18180144e+01 -1.40727883 0.68728137 78.50 -5.51406118e+00 -1.33746171e+01 1.44666946e+01 -1.96184222 0.68730576 78.75 -8.16354087e+00 -9.29985310e+00 1.23745977e+01 -2.29121785 0.67520092 79.00 -8.03659527e+00 -2.70018312e+00 8.47808070e+00 -2.81745664 0.60156520 79.25 -7.25908330e+00 -8.36109514e-01 7.30707667e+00 -3.02691685 0.58174739 79.50 -6.92157872e+00 1.35000869e+00 7.05200507e+00 2.94896750 0.54265050 79.75 -5.81277786e+00 1.71853539e+00 6.06149737e+00 2.85413341 0.40736840 80.00 -5.29185592e+00 1.01012990e+00 5.38740211e+00 2.95297778 0.18700085 80.25 -1.56787186e+00 4.08865877e+00 4.37896708e+00 1.93697069 0.17157051 80.50 -5.80376037e-01 3.35337912e+00 3.40323197e+00 1.74217068 0.23484931 80.75 -1.44202154e+00 3.26455524e+00 3.56885794e+00 1.98674387 0.25575699 81.00 8.47881466e-01 4.64720193e+00 4.72391667e+00 1.39033140 0.25912342 81.25 3.84400488e+00 3.01200663e+00 4.88349848e+00 0.66463556 0.31216201 81.50 3.84125026e+00 2.00400122e+00 4.33257711e+00 0.48086081 0.46925670 81.75 3.42538871e+00 1.44138393e+00 3.71629862e+00 0.39830297 0.49801164 82.00 3.36200968e+00 1.06703063e+00 3.52727422e+00 0.30732343 0.58849021 82.25 3.08240193e+00 7.04702156e-01 3.16193086e+00 0.22475838 0.51621517 82.50 3.04934413e+00 5.52944692e-01 3.09907203e+00 0.17938316 0.55114829 82.75 2.54361191e+00 7.28289414e-01 2.64582067e+00 0.27886046 0.51008420 83.00 2.42579321e+00 4.27906508e-01 2.46324515e+00 0.17460238 0.58068645 83.25 2.12023237e+00 4.96827426e-01 2.17766453e+00 0.23017397 0.51494373 83.50 2.09881872e+00 4.15381632e-01 2.13952844e+00 0.19538717 0.59388725 83.75 2.01519512e+00 2.29232236e-01 2.02819102e+00 0.11326502 0.52003171 84.00 2.02243922e+00 1.38992841e-01 2.02720976e+00 0.06861745 0.58402520 84.25 1.63836208e+00 2.45393716e-01 1.65663768e+00 0.14867469 0.42649209 84.50 1.85273486e+00 3.58704344e-01 1.88713944e+00 0.19124195 0.45420660 84.75 1.88409031e+00 -2.07090365e-02 1.88420412e+00 -0.01099109 0.44125493 85.00 2.15204092e+00 -1.01807406e-01 2.15444769e+00 -0.04727213 0.67379518 85.25 1.95658207e+00 5.78788780e-02 1.95743796e+00 0.02957300 0.63566016 85.50 1.93657434e+00 4.41029937e-02 1.93707647e+00 0.02276978 0.65093307 85.75 1.67467507e+00 -1.08831446e-01 1.67820764e+00 -0.06489535 0.53157224 86.00 1.69044544e+00 -1.84978339e-01 1.70053603e+00 -0.10899215 0.60228333 86.25 1.39310874e+00 -3.86857363e-01 1.44582523e+00 -0.27086869 0.49903226 86.50 1.39382683e+00 -4.80435061e-01 1.47430359e+00 -0.33193450 0.56762448 86.75 1.14363798e+00 -6.41599051e-01 1.31131887e+00 -0.51126133 0.45282807 87.00 1.07003846e+00 -6.16102196e-01 1.23473245e+00 -0.52241708 0.42906696 87.25 7.31156486e-01 -4.35056324e-01 8.50801865e-01 -0.53675332 0.22866424 87.50 4.51250723e-01 -2.50567355e-01 5.16150380e-01 -0.50688258 0.10458400 87.75 5.13724414e-01 4.81121980e-02 5.15972439e-01 0.09338133 0.14344947 88.00 6.45954634e-01 8.36457735e-02 6.51347837e-01 0.12877513 0.23799679 88.25 7.05691255e-01 3.14631260e-01 7.72653206e-01 0.41939603 0.36208478 88.50 6.97867075e-01 4.38822270e-01 8.24368509e-01 0.56133078 0.40051384 88.75 3.83891172e-01 4.77004317e-01 6.12295313e-01 0.89313782 0.20740494 89.00 5.09085576e-01 4.42458428e-01 6.74490611e-01 0.71549222 0.19784620 89.25 5.91085400e-01 4.77275026e-01 7.59719291e-01 0.67927034 0.16503757 89.50 3.42264902e-01 4.77269024e-01 5.87308253e-01 0.94866466 0.07833537 89.75 5.25210361e-01 9.84811663e-01 1.11610928e+00 1.08085681 0.17096461 90.00 5.59170984e-01 5.43661507e-01 7.79897445e-01 0.77133578 0.07272835 90.25 1.02409193e+00 -7.16670705e-01 1.24995247e+00 -0.61059905 0.23445423 90.50 1.15149579e+00 -5.40972768e-01 1.27223979e+00 -0.43919709 0.47020738 90.75 1.21206017e+00 -2.69202598e-01 1.24159570e+00 -0.21855564 0.70263734 91.00 1.37300065e+00 -2.32293434e-01 1.39251249e+00 -0.16759958 0.64023719 91.25 1.65082056e+00 -2.02600357e-01 1.66320636e+00 -0.12211640 0.67972888 91.50 1.37405668e+00 -5.89994661e-01 1.49536800e+00 -0.40557604 0.58909189 91.75 1.13581021e+00 -6.53414677e-01 1.31034941e+00 -0.52204851 0.81821231 92.00 1.09924025e+00 -4.40961135e-01 1.18438839e+00 -0.38149807 0.85540310 92.25 1.11700298e+00 -3.40681329e-01 1.16780111e+00 -0.29603386 0.88442274 92.50 1.18000832e+00 -3.38341115e-01 1.22755625e+00 -0.27923637 0.80652154 92.75 1.22770377e+00 -3.47375474e-01 1.27590214e+00 -0.27573964 0.74457948 93.00 1.10889533e+00 -3.93611503e-01 1.17668129e+00 -0.34108509 0.59717676 93.25 9.56544114e-01 -5.58171258e-01 1.10748896e+00 -0.52822045 0.60952557 93.50 7.56180501e-01 -4.89965559e-01 9.01041175e-01 -0.57493126 0.49165014 93.75 6.71619960e-01 -4.44689115e-01 8.05494742e-01 -0.58484427 0.58306273 94.00 7.44189977e-01 -1.78631573e-01 7.65328662e-01 -0.23557799 0.54996442 94.25 7.71134841e-01 -5.37880112e-02 7.73008469e-01 -0.06963897 0.64673508 94.50 7.95015985e-01 -1.21433299e-01 8.04236571e-01 -0.15157171 0.54427958 94.75 8.47929776e-01 -2.07570323e-01 8.72966405e-01 -0.24007538 0.63652141 95.00 7.23781432e-01 -3.75993595e-01 8.15616788e-01 -0.47911382 0.49404790 95.25 6.18295614e-01 -5.49662428e-01 8.27295746e-01 -0.72670226 0.49577693 95.50 4.05602265e-01 -4.18962562e-01 5.83131911e-01 -0.80159959 0.35027490 95.75 1.86623616e-01 -3.22395041e-01 3.72514344e-01 -1.04606130 0.24242326 96.00 -1.49628842e-02 -1.62554194e-01 1.63241397e-01 -1.66258626 0.04069757 96.25 -9.55043285e-02 -8.06485336e-02 1.25001051e-01 -2.44033008 0.02742042 96.50 -1.82125437e-01 -7.42714569e-02 1.96687377e-01 -2.75437696 0.04679467 96.75 -3.24096583e-01 -8.98282902e-02 3.36314908e-01 -2.87121460 0.14180962 97.00 -5.24916394e-01 2.64105337e-02 5.25580381e-01 3.09132125 0.36065394 97.25 -6.55375656e-01 1.36169815e-01 6.69372444e-01 2.93673369 0.51295865 97.50 -9.03839944e-01 2.59620828e-01 9.40388015e-01 2.86188111 0.63096041 97.75 -1.12232556e+00 3.82753875e-01 1.18579728e+00 2.81292543 0.76165288 98.00 -1.49395510e+00 5.53333118e-01 1.59313508e+00 2.78687734 0.82069196 98.25 -1.69473316e+00 9.50002970e-01 1.94283970e+00 2.63067662 0.86164389 98.50 -1.88098957e+00 1.31652442e+00 2.29594389e+00 2.53092673 0.91209063 98.75 -2.19948204e+00 1.56266886e+00 2.69808362e+00 2.52387349 0.90255966 99.00 -2.65457548e+00 2.11409667e+00 3.39354913e+00 2.46905236 0.90832216 99.25 -3.01331882e+00 2.59342858e+00 3.97567128e+00 2.43094512 0.86529836 99.50 -3.87793589e+00 4.47610989e+00 5.92232610e+00 2.28471357 0.89471987 99.75 -3.83969626e+00 5.63167670e+00 6.81608758e+00 2.16920512 0.87868770 100.00 -2.51510888e+00 8.99432340e+00 9.33935898e+00 1.84346460 0.87249933 100.25 -7.35214396e-01 1.09927850e+01 1.10173437e+01 1.63757841 0.86828357 100.50 4.91990122e+00 1.07485392e+01 1.18210204e+01 1.14153488 0.87518699 100.75 6.86345817e+00 8.35479185e+00 1.08124745e+01 0.88308266 0.85348999 101.00 7.73598450e+00 4.38277494e+00 8.89124132e+00 0.51545609 0.93045144 101.25 7.41454820e+00 3.32901238e+00 8.12759794e+00 0.42200857 0.94538557 101.50 6.74574636e+00 2.40161773e+00 7.16050708e+00 0.34202737 0.95817895 101.75 6.34825030e+00 1.90203307e+00 6.62706659e+00 0.29110384 0.95849358 102.00 5.81509236e+00 1.45873816e+00 5.99526614e+00 0.24578210 0.97759668 102.25 5.55856068e+00 1.10662547e+00 5.66764649e+00 0.19651550 0.97572661 102.50 5.26265404e+00 8.02181313e-01 5.32344084e+00 0.15126469 0.98781789 102.75 4.99612182e+00 7.12245616e-01 5.04663522e+00 0.14160555 0.98545501 103.00 4.72954490e+00 5.31633467e-01 4.75933074e+00 0.11193702 0.99150687 103.25 4.61565472e+00 4.17135270e-01 4.63446549e+00 0.09012918 0.98960814 103.50 4.42470609e+00 3.15601135e-01 4.43594726e+00 0.07120644 0.99412829 103.75 4.28077572e+00 2.76537047e-01 4.28969853e+00 0.06451011 0.99240637 104.00 4.18992484e+00 2.71517862e-01 4.19871315e+00 0.06471208 0.99632643 104.25 4.15148779e+00 2.35285673e-01 4.15814985e+00 0.05661446 0.99577621 104.50 4.08148719e+00 1.43668646e-01 4.08401498e+00 0.03518555 0.99635295 104.75 4.00844051e+00 9.87246941e-02 4.00965608e+00 0.02462422 0.99410006 105.00 3.94181672e+00 3.73487355e-02 3.94199365e+00 0.00947472 0.99363674 105.25 3.83514121e+00 1.51382101e-04 3.83514121e+00 0.00003947 0.99354049 105.50 3.77183177e+00 -3.74566289e-02 3.77201775e+00 -0.00993029 0.99597423 105.75 3.75849969e+00 -3.11311207e-02 3.75862862e+00 -0.00828267 0.99459984 106.00 3.72880103e+00 -4.79504492e-02 3.72910932e+00 -0.01285877 0.99732097 106.25 3.72512892e+00 -7.11754539e-02 3.72580882e+00 -0.01910452 0.99724609 106.50 3.73123537e+00 -8.57174011e-02 3.73221983e+00 -0.02296889 0.99752840 106.75 3.76874613e+00 -1.62883059e-01 3.77226435e+00 -0.04319255 0.99580256 107.00 3.78807518e+00 -2.54749162e-01 3.79663149e+00 -0.06714918 0.99595283 107.25 3.72301717e+00 -3.57440916e-01 3.74013648e+00 -0.09571503 0.99457827 107.50 3.69713819e+00 -3.90236281e-01 3.71767605e+00 -0.10516152 0.99622038 107.75 3.63565167e+00 -4.63275273e-01 3.66504940e+00 -0.12674261 0.99205948 108.00 3.62430900e+00 -6.10468397e-01 3.67536221e+00 -0.16687085 0.99162159 108.25 3.58993836e+00 -8.25976731e-01 3.68373384e+00 -0.22614535 0.98774813 108.50 3.40345384e+00 -9.52269378e-01 3.53416398e+00 -0.27281860 0.98493562 108.75 3.01689800e+00 -9.56143378e-01 3.16478810e+00 -0.30691500 0.98747295 109.00 2.93728009e+00 -9.29146188e-01 3.08073481e+00 -0.30636919 0.98960817 109.25 2.85440572e+00 -8.73790754e-01 2.98515364e+00 -0.29706200 0.98980601 109.50 2.74941380e+00 -8.50195477e-01 2.87786528e+00 -0.29990112 0.98847050 109.75 2.57093370e+00 -7.50849307e-01 2.67833433e+00 -0.28415026 0.97481815 110.00 2.59778373e+00 -5.99066746e-01 2.66596348e+00 -0.22664468 0.94699478 110.25 2.44531473e+00 -9.67568784e-01 2.62978202e+00 -0.37677905 0.89560826 110.50 2.16301434e+00 -8.26539508e-01 2.31555578e+00 -0.36500162 0.91193964 110.75 2.07573926e+00 -3.59416368e-01 2.10662612e+00 -0.17145107 0.97784575 111.00 2.09063764e+00 -2.99275580e-01 2.11194971e+00 -0.14218442 0.97900891 111.25 2.16141410e+00 -1.60817083e-01 2.16738853e+00 -0.07426680 0.97053561 111.50 2.15389216e+00 -8.41262218e-02 2.15553443e+00 -0.03903793 0.95912929 111.75 2.11601488e+00 -3.92807068e-02 2.11637944e+00 -0.01856140 0.95271608 112.00 2.15103085e+00 7.83687783e-02 2.15245798e+00 0.03641702 0.93547390 112.25 1.96394914e+00 2.70251185e-01 1.98245603e+00 0.13674719 0.94069884 112.50 1.93509476e+00 4.24016101e-01 1.98100514e+00 0.21570986 0.90166485 112.75 1.84240033e+00 8.37791895e-01 2.02394027e+00 0.42677917 0.89718701 113.00 2.01030592e+00 1.41947031e+00 2.46094003e+00 0.61480598 0.84317968 113.25 2.94362880e+00 2.06826019e+00 3.59758957e+00 0.61248395 0.91950064 113.50 3.45496075e+00 1.69168975e+00 3.84689069e+00 0.45532596 0.93582503 113.75 4.06957191e+00 9.44260730e-01 4.17768403e+00 0.22799506 0.95553648 114.00 4.22211137e+00 5.29658142e-01 4.25520413e+00 0.12479671 0.97543563 114.25 4.13105849e+00 2.48474223e-01 4.13852434e+00 0.06007546 0.98462025 114.50 3.92937455e+00 1.35508316e-01 3.93171042e+00 0.03447231 0.97370112 114.75 3.73680360e+00 3.31497923e-02 3.73695063e+00 0.00887093 0.97011540 115.00 3.73316198e+00 -1.24044626e-01 3.73522228e+00 -0.03321554 0.96396099 115.25 3.74359529e+00 -3.00157703e-01 3.75560918e+00 -0.08000784 0.97583807 115.50 3.60811450e+00 -3.26377358e-01 3.62284590e+00 -0.09021097 0.96999091 115.75 3.50752520e+00 -3.82884449e-01 3.52836131e+00 -0.10873034 0.96726944 116.00 3.33707184e+00 -3.46425211e-01 3.35500505e+00 -0.10344061 0.95719761 116.25 3.14529333e+00 -2.51421652e-01 3.15532613e+00 -0.07976623 0.96697578 116.50 3.01652234e+00 -1.83100599e-01 3.02207426e+00 -0.06062485 0.96880520 116.75 3.00609416e+00 -1.47508038e-01 3.00971107e+00 -0.04903034 0.97560204 117.00 3.03609892e+00 -5.06932774e-03 3.03610315e+00 -0.00166968 0.97570287 117.25 3.11341158e+00 6.64468314e-02 3.11412056e+00 0.02133889 0.98504002 117.50 3.14997116e+00 3.99611102e-02 3.15022462e+00 0.01268550 0.98299445 117.75 3.18128170e+00 9.00279393e-02 3.18255531e+00 0.02829172 0.98621570 118.00 3.33810079e+00 1.63282843e-01 3.34209189e+00 0.04887594 0.98156763 118.25 3.42394268e+00 8.99016880e-02 3.42512274e+00 0.02625074 0.98120799 118.50 3.28082737e+00 -3.79630258e-01 3.30271818e+00 -0.11519942 0.95548945 118.75 2.93159966e+00 -5.44785889e-01 2.98178943e+00 -0.18373640 0.95720194 119.00 2.40954000e+00 -1.23745509e-01 2.41271548e+00 -0.05131141 0.92597168 119.25 2.42307110e+00 2.54912768e-01 2.43644292e+00 0.10481679 0.94590245 119.50 2.59380868e+00 7.64479171e-01 2.70412128e+00 0.28661705 0.96816616 119.75 2.74203624e+00 9.00393651e-01 2.88608237e+00 0.31727403 0.97223796 120.00 2.90687638e+00 9.44355617e-01 3.05642566e+00 0.31411391 0.96431998 120.25 2.97890711e+00 1.00587210e+00 3.14414794e+00 0.32564380 0.95950612 120.50 2.99452415e+00 1.33270157e+00 3.27769253e+00 0.41872671 0.95201916 120.75 2.99574118e+00 1.56072010e+00 3.37791539e+00 0.48029009 0.93494130 121.00 3.34071235e+00 1.94729404e+00 3.86682210e+00 0.52774947 0.93750504 121.25 3.62868771e+00 2.15367630e+00 4.21967962e+00 0.53563660 0.91931692 121.50 4.76653721e+00 2.04574487e+00 5.18699807e+00 0.40541333 0.90964310 121.75 5.38483843e+00 1.70672376e+00 5.64883979e+00 0.30693368 0.93066098 122.00 5.37955891e+00 1.63799665e+00 5.62340529e+00 0.29556666 0.96280957 122.25 5.68910834e+00 1.60523079e+00 5.91123672e+00 0.27500924 0.95569050 122.50 6.11207010e+00 1.21229470e+00 6.23113628e+00 0.19580310 0.93153748 122.75 7.16183654e+00 7.30850238e-01 7.19903082e+00 0.10169584 0.89613955 123.00 8.61975804e+00 -1.06430829e+00 8.68521622e+00 -0.12285131 0.86050646 123.25 6.78943458e+00 -4.07815057e+00 7.92008422e+00 -0.54090560 0.72462098 123.50 2.33954718e+00 -4.45211728e+00 5.02939651e+00 -1.08696456 0.68744005 123.75 1.39344555e+00 -2.50651373e+00 2.86780432e+00 -1.06341193 0.42354113 124.00 1.62832304e+00 1.22375388e-01 1.63291508e+00 0.07501323 0.35827812 124.25 1.87926971e+00 4.02027131e-01 1.92179095e+00 0.21075065 0.54718576 124.50 1.75042133e+00 8.68841426e-01 1.95419044e+00 0.46073242 0.55096894 124.75 2.09819901e+00 7.95539385e-01 2.24395232e+00 0.36240707 0.50434285 125.00 2.16783143e+00 6.71658985e-01 2.26949750e+00 0.30045047 0.51900113 125.25 1.61162783e+00 1.03394066e+00 1.91477872e+00 0.57041238 0.45545448 125.50 1.19002581e+00 1.51722884e+00 1.92824915e+00 0.90567634 0.48683452 125.75 9.15785043e-01 1.40843700e+00 1.67998721e+00 0.99427089 0.44104566 126.00 6.13903570e-01 1.49224460e+00 1.61358965e+00 1.18050452 0.49000675 126.25 -4.76908735e-02 1.37612574e+00 1.37695188e+00 1.60543836 0.23683307 126.50 -8.50694215e-01 1.63347926e+00 1.84172070e+00 2.05093465 0.30587997 126.75 -1.95496100e+00 1.21123885e+00 2.29977652e+00 2.58690624 0.26108332 127.00 -2.85083267e+00 6.46684701e-01 2.92325983e+00 2.91852696 0.25969377 127.25 -3.68703231e-01 1.63185470e+00 1.67298889e+00 1.79300645 0.06841369 127.50 4.63170131e-01 2.99684637e+00 3.03242720e+00 1.41745705 0.23162717 127.75 -8.43071777e-01 1.75532594e+00 1.94729021e+00 2.01855488 0.19127840 128.00 -1.35418242e+00 1.21488815e+00 1.81927547e+00 2.41036117 0.20679938 128.25 -1.01816117e+00 3.50916945e-01 1.07693773e+00 2.80968515 0.14554609 128.50 -6.42875260e-01 7.43113047e-02 6.47155908e-01 3.02651129 0.09768527 128.75 1.15824834e+00 -9.77349391e-01 1.51550357e+00 -0.70089342 0.40923004 129.00 1.87854628e+00 -1.74157967e+00 2.56164710e+00 -0.74758144 0.56374329 129.25 2.98837276e+00 -3.77989598e+00 4.81850448e+00 -0.90181555 0.70159441 129.50 2.89036841e+00 -4.81001190e+00 5.61163470e+00 -1.02971040 0.72872737 129.75 2.37624653e+00 -6.02778953e+00 6.47925877e+00 -1.19528673 0.75111986 130.00 2.06743710e+00 -6.99320415e+00 7.29240704e+00 -1.28334876 0.74996110 130.25 2.29159492e+00 -8.65088180e+00 8.94925489e+00 -1.31184659 0.82733169 130.50 1.55075066e+00 -9.98185754e+00 1.01015993e+01 -1.41667150 0.83232845 130.75 -7.36087803e-01 -1.12858657e+01 1.13098449e+01 -1.63592617 0.68967294 131.00 -3.59144179e+00 -9.36509653e+00 1.00301290e+01 -1.93699138 0.58858216 131.25 -5.49622396e+00 -4.18708151e+00 6.90942323e+00 -2.49057553 0.58221969 131.50 -4.28486579e+00 -3.33531241e+00 5.42995245e+00 -2.48016585 0.67065832 131.75 -2.85974018e+00 -3.13474321e+00 4.24319796e+00 -2.31035062 0.79352873 132.00 -2.28445705e+00 -2.91316813e+00 3.70206598e+00 -2.23581810 0.73659126 132.25 -2.54546039e+00 -2.80789128e+00 3.78993694e+00 -2.30721191 0.77574072 132.50 -2.31697852e+00 -2.31037301e+00 3.27203498e+00 -2.35762198 0.71822717 132.75 -1.64070231e+00 -1.74266174e+00 2.39348575e+00 -2.32606809 0.75689683 133.00 -1.60006176e+00 -1.69483635e+00 2.33080842e+00 -2.32743838 0.80319482 133.25 -1.31428170e+00 -1.40033346e+00 1.92048697e+00 -2.32450567 0.79258921 133.50 -9.40760005e-01 -1.13288059e+00 1.47256505e+00 -2.26380929 0.72768143 133.75 -6.20387715e-01 -7.34650798e-01 9.61557441e-01 -2.27206891 0.67338624 134.00 -1.71703755e-01 -4.31007036e-01 4.63949614e-01 -1.94990372 0.35849284 134.25 2.55874897e-01 -3.54348940e-01 4.37075662e-01 -0.94539249 0.50463800 134.50 4.75092851e-01 -4.95215009e-01 6.86258787e-01 -0.80613310 0.77628273 134.75 5.81122926e-01 -4.77670111e-01 7.52245033e-01 -0.68799908 0.89207134 135.00 8.00062668e-01 -3.02593088e-01 8.55372930e-01 -0.36158346 0.87113655 135.25 9.77973418e-01 -1.38172277e-01 9.87685975e-01 -0.14035532 0.93020116 135.50 1.28361342e+00 -6.89297149e-02 1.28546284e+00 -0.05364822 0.92239353 135.75 1.68510233e+00 -6.76957494e-02 1.68646155e+00 -0.04015149 0.95906454 136.00 1.91970342e+00 -9.85871008e-02 1.92223324e+00 -0.05131030 0.96702565 136.25 2.03229563e+00 -1.26895529e-01 2.03625342e+00 -0.06235855 0.98192440 136.50 2.15427126e+00 -3.75554611e-02 2.15459858e+00 -0.01743126 0.97475498 136.75 2.26299369e+00 7.03816325e-02 2.26408790e+00 0.03109110 0.98225011 137.00 2.50312809e+00 2.57963851e-01 2.51638542e+00 0.10269406 0.96937652 137.25 2.78113171e+00 3.84606394e-01 2.80759963e+00 0.13741972 0.98082078 137.50 3.13529100e+00 3.30543435e-01 3.15266690e+00 0.10503870 0.98045606 137.75 3.35121741e+00 3.48498174e-01 3.36928911e+00 0.10361907 0.98685838 138.00 3.56202444e+00 2.25479454e-01 3.56915383e+00 0.06321658 0.98011794 138.25 3.62499316e+00 2.05767566e-01 3.63082852e+00 0.05670273 0.98438365 138.50 3.53207136e+00 2.67105947e-01 3.54215664e+00 0.07547937 0.95417451 138.75 3.70275503e+00 3.43114756e-01 3.71861837e+00 0.09240085 0.94459930 139.00 3.82159970e+00 3.08535971e-01 3.83403426e+00 0.08056004 0.94917964 139.25 3.94425243e+00 3.47084267e-01 3.95949425e+00 0.08777139 0.95706810 139.50 3.79537893e+00 9.25782419e-01 3.90665769e+00 0.23925155 0.93735891 139.75 3.89983692e+00 1.16128665e+00 4.06906804e+00 0.28941726 0.92692807 140.00 4.46537841e+00 1.79842145e+00 4.81393021e+00 0.38287295 0.91123805 140.25 4.78565176e+00 2.27736303e+00 5.29989105e+00 0.44416048 0.89193893 140.50 5.74671008e+00 3.61436860e+00 6.78883916e+00 0.56143164 0.90048615 140.75 6.29187462e+00 4.67575412e+00 7.83902818e+00 0.63909730 0.90525640 141.00 8.13374324e+00 6.03188826e+00 1.01262755e+01 0.63809580 0.90822708 141.25 1.01191088e+01 5.50154300e+00 1.15179572e+01 0.49797699 0.89462380 141.50 1.31205847e+01 2.71715222e+00 1.33989798e+01 0.20420423 0.92659712 141.75 1.36086105e+01 7.21310407e-01 1.36277133e+01 0.05295442 0.93113602 142.00 1.29553308e+01 -5.51097882e-01 1.29670469e+01 -0.04251268 0.95945478 142.25 1.28326556e+01 -7.11886259e-01 1.28523863e+01 -0.05541778 0.95732234 142.50 1.29349526e+01 -1.82605892e+00 1.30632113e+01 -0.14024567 0.94456225 142.75 1.31140073e+01 -2.59210791e+00 1.33677302e+01 -0.19514405 0.92042287 143.00 1.46570767e+01 -3.71956959e+00 1.51216763e+01 -0.24852651 0.89845945 143.25 1.39905612e+01 -3.94479106e+00 1.45360648e+01 -0.27482611 0.87934401 143.50 1.35962403e+01 -4.44389315e+00 1.43040531e+01 -0.31590173 0.85940534 143.75 1.37567346e+01 -5.20894683e+00 1.47098903e+01 -0.36196424 0.86694887 144.00 1.57295127e+01 -5.79886869e+00 1.67643804e+01 -0.35320225 0.89314623 144.25 1.57107790e+01 -6.17893782e+00 1.68821755e+01 -0.37471106 0.83620262 144.50 1.58336702e+01 -8.14817086e+00 1.78072402e+01 -0.47526747 0.82654017 144.75 1.46478556e+01 -8.80386211e+00 1.70899872e+01 -0.54117959 0.76921588 145.00 1.47567383e+01 -1.19993354e+01 1.90196050e+01 -0.68270362 0.73764324 145.25 1.49010292e+01 -1.49700060e+01 2.11220679e+01 -0.78770731 0.77144487 145.50 1.38610744e+01 -1.63072331e+01 2.14022249e+01 -0.86630489 0.78765588 145.75 9.20604826e+00 -1.63765745e+01 1.87867910e+01 -1.05867478 0.71760448 146.00 4.80669840e+00 -1.82536522e+01 1.88759150e+01 -1.31331350 0.77395581 146.25 3.64027377e+00 -2.01891170e+01 2.05146786e+01 -1.39240438 0.85654865 146.50 3.93857191e+00 -2.11097766e+01 2.14740545e+01 -1.38634141 0.90584745 146.75 3.27215157e+00 -2.12597049e+01 2.15100448e+01 -1.41808139 0.91352950 147.00 3.76957497e+00 -2.16016831e+01 2.19281191e+01 -1.39803219 0.89530209 147.25 1.56989600e+00 -1.87037563e+01 1.87695251e+01 -1.48705781 0.74001372 147.50 -4.35821721e+00 -1.80800398e+01 1.85979003e+01 -1.80733512 0.66138763 147.75 -4.54468502e+00 -1.14359158e+01 1.23058658e+01 -1.94906325 0.47139779 148.00 -3.13262837e+00 -7.96827347e+00 8.56193568e+00 -1.94537293 0.37822204 148.25 -5.69586630e-01 -4.07377964e+00 4.11340607e+00 -1.70971350 0.13902819 148.50 -8.57982389e-02 -3.66975914e+00 3.67076198e+00 -1.59417187 0.20039763 148.75 7.09939342e-01 -4.11553019e+00 4.17631447e+00 -1.39997495 0.28688614 149.00 1.17583857e+00 -3.70282904e+00 3.88504044e+00 -1.26331611 0.27570656 149.25 2.30906663e+00 -2.52796981e+00 3.42380199e+00 -0.83062294 0.21917449 149.50 2.54198825e+00 -1.94591830e+00 3.20129697e+00 -0.65335405 0.26172332 149.75 3.04268796e+00 -2.38740371e+00 3.86751167e+00 -0.66530243 0.38737956 150.00 3.27513660e+00 -2.29519187e+00 3.99930312e+00 -0.61125779 0.43417504 150.25 4.02540293e+00 -1.11031585e+00 4.17572389e+00 -0.26913514 0.39549996 150.50 4.59896876e+00 -8.80166025e-01 4.68243590e+00 -0.18909675 0.41911535 150.75 4.87858897e+00 -9.65404851e-01 4.97319182e+00 -0.19536212 0.57120547 151.00 4.44103690e+00 -7.32858702e-01 4.50109882e+00 -0.16354582 0.53255296 151.25 3.79692635e+00 -6.25836293e-01 3.84815810e+00 -0.16335828 0.40725045 151.50 3.69246412e+00 -4.55148696e-01 3.72041014e+00 -0.12264555 0.39401542 151.75 3.41834363e+00 5.08651058e-01 3.45598019e+00 0.14771658 0.39801313 152.00 3.21388412e+00 1.08486592e-01 3.21571461e+00 0.03374279 0.36884134 152.25 3.12519888e+00 -4.07680986e-01 3.15167762e+00 -0.12971712 0.34658988 152.50 3.53816587e+00 -3.43543069e-01 3.55480514e+00 -0.09679295 0.35527011 152.75 5.16536904e+00 1.21593504e+00 5.30655589e+00 0.23119231 0.53149289 153.00 4.99606813e+00 1.23675966e+00 5.14687004e+00 0.24266825 0.51244355 153.25 4.70998900e+00 1.08420294e+00 4.83316588e+00 0.22625097 0.53669354 153.50 4.50752419e+00 1.27351852e+00 4.68397521e+00 0.27535481 0.52397414 153.75 4.03491572e+00 1.66616112e+00 4.36539091e+00 0.39160794 0.52917015 154.00 3.84840171e+00 7.86974747e-01 3.92804341e+00 0.20171288 0.48754920 154.25 4.67898003e+00 6.63559013e-01 4.72579778e+00 0.14087759 0.58971831 154.50 4.60962839e+00 -1.35413188e-01 4.61161692e+00 -0.02936772 0.61279917 154.75 4.34241678e+00 -5.83194137e-01 4.38140376e+00 -0.13350290 0.65362348 155.00 3.86123029e+00 -7.62119178e-01 3.93572420e+00 -0.19487246 0.58954626 155.25 3.42848352e+00 -1.27790991e+00 3.65890052e+00 -0.35678193 0.58431481 155.50 2.91095779e+00 -1.46940777e+00 3.26080273e+00 -0.46746826 0.43717963 155.75 3.27391254e+00 -1.66910301e+00 3.67483444e+00 -0.47147196 0.50649239 156.00 2.72132599e+00 -1.50134790e+00 3.10799946e+00 -0.50414530 0.38735453 156.25 2.08681256e+00 -1.98549337e+00 2.88044625e+00 -0.76052324 0.44829508 156.50 2.16153647e+00 -2.54462974e+00 3.33876929e+00 -0.86662148 0.48470709 156.75 2.10368572e+00 -3.25977833e+00 3.87964539e+00 -0.99769960 0.45971357 157.00 1.38062522e+00 -2.91458345e+00 3.22504615e+00 -1.12841284 0.32936849 157.25 5.78148552e-01 -4.10562702e+00 4.14613422e+00 -1.43089764 0.37344231 157.50 1.32025947e-01 -3.69164682e+00 3.69400692e+00 -1.53504813 0.23892263 157.75 -2.00300928e+00 -2.82768430e+00 3.46523372e+00 -2.18710886 0.13251037 158.00 -3.81711331e+00 -3.45085474e+00 5.14575092e+00 -2.40654543 0.19273759 158.25 -7.14775691e+00 -1.81813615e+00 7.37536764e+00 -2.89251039 0.25853199 158.50 -7.16702768e+00 2.41966864e+00 7.56446179e+00 2.81599699 0.24308547 158.75 -4.32979508e+00 6.51955175e+00 7.82634528e+00 2.15703701 0.24222591 159.00 -2.36321392e+00 5.91327490e+00 6.36801383e+00 1.95099709 0.22094617 159.25 -1.69090984e+00 5.07494121e+00 5.34922465e+00 1.89241613 0.18951113 159.50 8.40716456e-01 3.49637255e+00 3.59602908e+00 1.33482220 0.15078280 159.75 1.87895105e+00 3.65411671e+00 4.10889596e+00 1.09585244 0.20253957 160.00 3.58322658e+00 2.96950836e+00 4.65376112e+00 0.69201225 0.21775562 160.25 4.90116669e+00 3.62786378e+00 6.09777259e+00 0.63720221 0.30554362 160.50 6.10806057e+00 4.58325756e+00 7.63640319e+00 0.64373285 0.40931578 160.75 7.37975347e+00 4.52479067e+00 8.65647110e+00 0.55002219 0.50108657 161.00 8.26935458e+00 5.03406590e+00 9.68111795e+00 0.54683699 0.47758857 161.25 9.97931303e+00 5.02614259e+00 1.11735759e+01 0.46656827 0.50231328 161.50 9.89308066e+00 3.03119937e+00 1.03470389e+01 0.29731422 0.45875608 161.75 9.78777772e+00 3.04330325e+00 1.02499896e+01 0.30145293 0.41495840 162.00 9.71492526e+00 2.42104000e+00 1.00120531e+01 0.24423339 0.42455472 162.25 9.71421727e+00 7.48034893e-01 9.74297559e+00 0.07685247 0.38620929 162.50 1.10904923e+01 -3.08686500e+00 1.15120700e+01 -0.27146348 0.53454373 162.75 1.17687591e+01 -2.12847634e+00 1.19596866e+01 -0.17892406 0.53796850 163.00 1.51456295e+01 -3.00087506e+00 1.54400564e+01 -0.19560138 0.72323227 163.25 1.59196905e+01 -4.39322871e+00 1.65147511e+01 -0.26926030 0.72806146 163.50 1.62983688e+01 -4.79859070e+00 1.69900941e+01 -0.28633111 0.62729609 163.75 1.09346102e+01 -4.34919886e+00 1.17678049e+01 -0.37856187 0.41538095 164.00 8.91140828e+00 -2.03049212e+00 9.13980830e+00 -0.22402841 0.28284764 164.25 6.94054210e+00 -2.32190664e+00 7.31863204e+00 -0.32283845 0.22971481 164.50 8.07219425e+00 -4.63708166e+00 9.30928818e+00 -0.52142174 0.30538059 164.75 5.97201252e+00 -3.80142298e+00 7.07924786e+00 -0.56685451 0.17729391 165.00 6.44176479e+00 -3.61360537e+00 7.38610028e+00 -0.51122273 0.16039128 165.25 5.33697101e+00 -4.08405227e+00 6.72032309e+00 -0.65318222 0.11524644 165.50 6.00419333e+00 -2.09148737e+00 6.35803877e+00 -0.33519323 0.07315970 165.75 1.74305789e+00 -2.81401941e+00 3.31012931e+00 -1.01622018 0.02299132 166.00 -2.07737529e+00 -3.78848451e+00 4.32066001e+00 -2.07236370 0.03525371 166.25 -2.36309595e+00 -4.51611874e+00 5.09701392e+00 -2.05287686 0.05272913 166.50 -9.31080252e+00 -6.06707805e+00 1.11130770e+01 -2.56408148 0.14419974 166.75 -8.99218391e+00 -7.11395813e+00 1.14659396e+01 -2.47228564 0.20430802 167.00 -1.07064032e+01 -6.78733486e+00 1.26765525e+01 -2.57658255 0.24695784 167.25 -8.81012372e+00 -6.31957583e+00 1.08422931e+01 -2.51934451 0.21971855 167.50 -9.52663711e+00 -8.47599043e+00 1.27514402e+01 -2.41448911 0.20769669 167.75 -9.25873709e+00 -9.43861080e+00 1.32216333e+01 -2.34657451 0.24292681 168.00 -1.40377634e+01 -9.20323026e+00 1.67856560e+01 -2.56128715 0.27090440 168.25 -2.23658178e+01 -1.16917193e+01 2.52373950e+01 -2.65991155 0.41757514 168.50 -3.30625945e+01 -1.02901869e+01 3.46269130e+01 -2.83986203 0.55432212 168.75 -3.45469250e+01 -4.92893177e+00 3.48967677e+01 -2.99987554 0.71343902 169.00 -3.60744123e+01 -4.31802710e+00 3.63319223e+01 -3.02246167 0.82446548 169.25 -3.36647382e+01 -1.36004172e-01 3.36650129e+01 -3.13755272 0.90086782 169.50 -3.28979998e+01 1.09201085e+00 3.29161188e+01 3.10841100 0.94403233 169.75 -3.20595448e+01 2.02174623e+00 3.21232294e+01 3.07861383 0.94764180 170.00 -3.13766493e+01 2.01588058e+00 3.14413405e+01 3.07743304 0.95940056 170.25 -3.20988930e+01 4.34889771e+00 3.23921571e+01 3.00692827 0.96521825 170.50 -3.20198144e+01 4.41892422e+00 3.23232951e+01 3.00445298 0.96931078 170.75 -3.22987800e+01 5.73920308e+00 3.28047198e+01 2.96573713 0.90332438 171.00 -3.26269118e+01 5.08676780e+00 3.30210627e+01 2.98693064 0.81086089 171.25 -2.07776208e+01 3.66482860e+00 2.10983529e+01 2.96700496 0.41047260 171.50 -9.60901850e+00 1.07536804e+00 9.66900475e+00 3.03014401 0.11983821 171.75 -8.24106765e+00 8.11955244e-02 8.24146763e+00 3.13174042 0.19902812 172.00 -6.25145170e+00 1.99436583e+00 6.56187042e+00 2.83277491 0.22336359 172.25 -9.04466182e+00 1.63206514e+00 9.19073142e+00 2.96306859 0.44393082 172.50 -9.40269529e+00 1.83362937e+00 9.57981604e+00 2.94899874 0.51761193 172.75 -8.66032643e+00 2.67592076e+00 9.06431496e+00 2.84191223 0.59968943 173.00 -8.10030697e+00 3.50403032e+00 8.82571252e+00 2.73331928 0.57583245 173.25 -7.09211180e+00 2.30595054e+00 7.45757720e+00 2.82723142 0.47532349 173.50 -6.38006209e+00 1.46687836e+00 6.54652002e+00 2.91560405 0.42879754 173.75 -5.47916171e+00 1.95951723e+00 5.81901373e+00 2.79813599 0.33490587 174.00 -5.63879961e+00 1.84520007e+00 5.93302826e+00 2.82534261 0.33380958 174.25 -1.06266049e+01 1.61903732e+00 1.07492332e+01 2.99039840 0.65307369 174.50 -1.04707212e+01 2.40989230e+00 1.07444676e+01 2.91537674 0.71165299 174.75 -1.00151665e+01 3.07045931e+00 1.04752699e+01 2.84410927 0.75456419 175.00 -9.34718630e+00 3.94216627e+00 1.01444845e+01 2.74247887 0.72536080 175.25 -9.66168459e+00 3.25488609e+00 1.01952162e+01 2.81664813 0.75757685 175.50 -9.64310261e+00 3.34626568e+00 1.02071995e+01 2.80758284 0.71808373 175.75 -1.10775277e+01 2.93381405e+00 1.14594453e+01 2.88269292 0.79514616 176.00 -1.04156533e+01 3.41925518e+00 1.09625335e+01 2.82439658 0.72819344 176.25 -1.15769024e+01 5.70193879e+00 1.29049129e+01 2.68394117 0.74669681 176.50 -8.84452402e+00 7.47607261e+00 1.15809009e+01 2.43984694 0.60961618 176.75 -7.09386858e+00 1.10552667e+01 1.31355202e+01 2.14129564 0.72010463 177.00 -5.23602070e+00 1.03582777e+01 1.16064563e+01 2.03882743 0.63036058 177.25 -4.47049163e+00 1.10533145e+01 1.19231311e+01 1.95513135 0.70006884 177.50 -1.50264757e+00 1.13423159e+01 1.14414195e+01 1.70251086 0.66774207 177.75 2.17701689e-02 1.07123057e+01 1.07123278e+01 1.56876407 0.67780174 178.00 1.88646548e+00 9.67143639e+00 9.85370153e+00 1.37815972 0.62249383 178.25 2.74346064e+00 8.62525772e+00 9.05105778e+00 1.26284246 0.58688273 178.50 2.08746733e+00 6.87841253e+00 7.18819023e+00 1.27614905 0.46399577 178.75 4.30445934e+00 7.18577144e+00 8.37637639e+00 1.03109378 0.44280174 179.00 7.55228728e+00 3.45024648e+00 8.30308641e+00 0.42853402 0.45260836 179.25 9.36829206e+00 9.65913437e-01 9.41795545e+00 0.10274150 0.52673574 179.50 6.45507624e+00 -4.11242656e+00 7.65376127e+00 -0.56724186 0.45146820 179.75 4.16033000e+00 -5.74006340e+00 7.08919414e+00 -0.94362700 0.56332694 180.00 1.18151457e+00 -5.56601202e+00 5.69003220e+00 -1.36162805 0.54445068 180.25 1.37711219e-01 -5.34471557e+00 5.34648940e+00 -1.54503616 0.59381272 180.50 -9.14017812e-01 -4.24921965e+00 4.34641187e+00 -1.78267047 0.58417812 180.75 -1.74465447e+00 -3.82595073e+00 4.20496352e+00 -1.99863317 0.63260458 181.00 -2.46829986e+00 -2.35168655e+00 3.40924241e+00 -2.38038347 0.55331356 181.25 -2.63569291e+00 -1.84315206e+00 3.21622241e+00 -2.53133358 0.54711833 181.50 -2.25923316e+00 -1.19286477e+00 2.55481131e+00 -2.65580035 0.45590223 181.75 -2.39553028e+00 -8.39627186e-01 2.53841272e+00 -2.80447477 0.51777573 182.00 -2.26191045e+00 -1.29102545e+00 2.60441656e+00 -2.62294487 0.59725868 182.25 -2.18715807e+00 -9.66902469e-01 2.39135125e+00 -2.72534310 0.57684813 182.50 -2.05056488e+00 -2.62542290e-01 2.06730375e+00 -3.01425133 0.53241428 182.75 -1.75729882e+00 -1.69041592e-01 1.76541049e+00 -3.04569373 0.47963051 183.00 -1.83326434e+00 2.71389264e-01 1.85324318e+00 2.99462396 0.46951273 183.25 -1.58746245e+00 3.56947082e-01 1.62709811e+00 2.92041730 0.40459262 183.50 -1.55919674e+00 -1.17888365e-02 1.55924130e+00 -3.13403196 0.36152967 183.75 -1.24260208e+00 -8.95355278e-02 1.24582364e+00 -3.06966210 0.27813788 184.00 -1.35904630e+00 1.80239932e-01 1.37094613e+00 3.00973974 0.37489699 184.25 -1.22319101e+00 1.42914873e-01 1.23151164e+00 3.02528225 0.31231886 184.50 -8.59203237e-01 5.80569310e-01 1.03696236e+00 2.54735771 0.22297979 184.75 -9.50806242e-01 5.38164698e-01 1.09254462e+00 2.62654175 0.24299986 185.00 -1.22516361e+00 6.02853452e-01 1.36545163e+00 2.68431756 0.38365565 185.25 -8.57702646e-01 8.66663400e-01 1.21932739e+00 2.35099799 0.31597587 185.50 -6.95435391e-02 1.35437483e+00 1.35615909e+00 1.62209861 0.34538720 185.75 5.38197786e-01 6.45600353e-01 8.40509769e-01 0.87587754 0.11924740 186.00 5.88956332e-01 -3.46564180e-01 6.83356636e-01 -0.53187452 0.09200073 186.25 -1.21830442e-02 -4.72047205e-01 4.72204395e-01 -1.59659955 0.04078641 186.50 -6.35204257e-01 -8.61647107e-01 1.07047662e+00 -2.20605348 0.25387411 186.75 -4.80090024e-01 -7.52888263e-01 8.92931782e-01 -2.13845082 0.16985793 187.00 -9.37089402e-01 -7.03508026e-01 1.17177647e+00 -2.49761980 0.34883642 187.25 -9.05364838e-01 -4.64298497e-01 1.01747658e+00 -2.66773359 0.29899556 187.50 -8.96077417e-01 -1.06863241e-01 9.02427000e-01 -3.02289654 0.31493605 187.75 -1.25131149e+00 -2.03235116e-01 1.26770854e+00 -2.98058095 0.48793995 188.00 -1.47792234e+00 -1.81677715e-01 1.48904709e+00 -3.01927851 0.65246082 188.25 -1.12630392e+00 6.18848838e-02 1.12800277e+00 3.08670274 0.51283439 188.50 -9.19123933e-01 2.72088922e-01 9.58551608e-01 2.85378136 0.52053846 188.75 -9.53067141e-01 3.57567585e-01 1.01793495e+00 2.78266800 0.36671912 189.00 -9.09363629e-01 4.10068444e-01 9.97546158e-01 2.71795729 0.32281070 189.25 -5.66631666e-01 4.33358254e-01 7.13351821e-01 2.48868847 0.17803286 189.50 -6.78705254e-01 6.27080216e-01 9.24051091e-01 2.39570953 0.29439283 189.75 -6.18989655e-01 5.51865771e-01 8.29279219e-01 2.41346073 0.22224600 190.00 -7.31163775e-01 4.25354027e-01 8.45888004e-01 2.61470088 0.29547026 190.25 -9.02176501e-01 3.18077418e-01 9.56606337e-01 2.80263305 0.42286641 190.50 -1.04785680e+00 4.21088386e-01 1.12930036e+00 2.75948661 0.62134395 190.75 -1.01446052e+00 2.73609916e-01 1.05071049e+00 2.87815135 0.55036409 191.00 -1.08580471e+00 2.62132202e-01 1.11699828e+00 2.90470786 0.55169051 191.25 -1.24519980e+00 4.32096572e-01 1.31804021e+00 2.80758416 0.58480730 191.50 -1.21139957e+00 4.81352970e-01 1.30352967e+00 2.76337046 0.58404471 191.75 -8.16990758e-01 3.86844584e-01 9.03948356e-01 2.69936943 0.15850173 192.00 -5.44037497e-01 2.85349344e-01 6.14329754e-01 2.65853528 0.04524160 192.25 -8.51391897e-01 4.07179937e-01 9.43749788e-01 2.69549427 0.18113225 192.50 -8.64526106e-01 3.82478946e-01 9.45354712e-01 2.72506465 0.19678871 192.75 -5.41233606e-01 3.64671660e-01 6.52624882e-01 2.54868250 0.13565566 193.00 -6.85021914e-01 4.57532348e-01 8.23766273e-01 2.55273042 0.23720912 193.25 -4.51288694e-01 8.03935536e-02 4.58393509e-01 2.96529981 0.10008605 193.50 -3.67991054e-01 1.24720706e-01 3.88552018e-01 2.81481968 0.06455621 193.75 -3.19798064e-01 -1.90012740e-01 3.71988767e-01 -2.60547482 0.05354626 194.00 -1.17523030e-01 -3.36830188e-01 3.56743939e-01 -1.90649873 0.04074410 194.25 -1.92437143e-01 -2.33883416e-01 3.02875397e-01 -2.25928049 0.02179363 194.50 6.02078766e-02 -3.18816103e-01 3.24451377e-01 -1.38414619 0.02248544 194.75 -1.56806753e-01 -1.49090815e-01 2.16371045e-01 -2.38141307 0.01013346 195.00 2.00815787e-02 -1.68990670e-01 1.70179659e-01 -1.45251852 0.00648987 195.25 8.20634923e-02 -3.32441668e-01 3.42420617e-01 -1.32878380 0.03745937 195.50 2.06852046e-01 -6.09811000e-01 6.43938837e-01 -1.24376899 0.10015189 195.75 3.59475192e-01 -1.32021360e+00 1.36827862e+00 -1.30495539 0.33960437 196.00 4.32976050e-01 -1.72440036e+00 1.77792712e+00 -1.32479403 0.35726666 196.25 3.43426161e-03 -2.23166071e+00 2.23166336e+00 -1.56925745 0.41787898 196.50 -9.90359728e-01 -2.73649912e+00 2.91019584e+00 -1.91803959 0.43455621 196.75 -2.70648713e+00 -4.07421826e+00 4.89125005e+00 -2.15715594 0.68663125 197.00 -3.21207533e+00 -3.66723230e+00 4.87504058e+00 -2.29012759 0.60422413 197.25 -4.80792355e+00 -3.29001621e+00 5.82583346e+00 -2.54148800 0.70481709 197.50 -5.03356027e+00 -2.80921952e+00 5.76441179e+00 -2.63255350 0.58587794 197.75 -5.82832029e+00 -2.93704566e+00 6.52652699e+00 -2.67480870 0.57010199 198.00 -5.99671687e+00 -2.20815097e+00 6.39034772e+00 -2.78877344 0.48069621 198.25 -6.71063909e+00 -1.52044387e-01 6.71236132e+00 -3.11893932 0.46371527 198.50 -6.07364033e+00 2.37461083e+00 6.52134062e+00 2.76889496 0.34840099 198.75 -5.20869448e+00 3.46411533e+00 6.25544508e+00 2.55470039 0.33134853 199.00 -3.32968909e+00 4.11135796e+00 5.29056648e+00 2.25153012 0.34518814 199.25 -3.14351006e+00 3.72664512e+00 4.87540146e+00 2.27151799 0.30016717 199.50 -9.85438313e-01 3.03958649e+00 3.19533640e+00 1.88430578 0.13076625 199.75 -8.80284787e-01 2.07715806e+00 2.25598912e+00 1.97164408 0.07795148 200.00 -1.21187455e+00 1.87503907e+00 2.23257955e+00 2.14457994 0.14870853 200.25 -1.09113439e+00 1.74910325e+00 2.06153740e+00 2.12855028 0.14651976 200.50 9.34041878e-01 7.56057973e-01 1.20168960e+00 0.68047519 0.09859034 200.75 1.05934545e+00 6.06423636e-01 1.22064017e+00 0.51991672 0.14631965 201.00 1.01365864e+00 7.83986554e-01 1.28145962e+00 0.65832386 0.16675092 201.25 1.12729675e+00 7.49611303e-01 1.35377807e+00 0.58682263 0.18418191 201.50 7.84539193e-01 4.45887841e-01 9.02395540e-01 0.51681744 0.12046712 201.75 7.59360907e-01 6.22878500e-01 9.82143886e-01 0.68697713 0.14431383 202.00 1.00491818e+00 5.41070100e-01 1.14132266e+00 0.49391075 0.14130611 202.25 1.02202614e+00 2.33099597e-01 1.04827136e+00 0.22424025 0.11324832 202.50 1.27004757e+00 2.36103032e-01 1.29180705e+00 0.18380275 0.17175110 202.75 1.17500052e+00 1.14382793e-01 1.18055480e+00 0.09704125 0.16788792 203.00 1.04284907e+00 2.43351218e-01 1.07086600e+00 0.22924991 0.18066677 203.25 9.35987677e-01 3.27319964e-01 9.91570113e-01 0.33641236 0.16242880 203.50 1.21878006e+00 1.36265157e-01 1.22637393e+00 0.11134215 0.30560834 203.75 1.06863991e+00 -5.40887697e-02 1.07000788e+00 -0.05057143 0.22802899 204.00 4.56798518e-01 -5.87103238e-02 4.60555956e-01 -0.12782488 0.08270344 204.25 4.54399212e-01 8.51627582e-02 4.62310869e-01 0.18526909 0.09966663 204.50 3.03960301e-01 -1.31965866e-01 3.31371173e-01 -0.40959934 0.06380230 204.75 3.39614527e-01 -1.88176230e-01 3.88263210e-01 -0.50597614 0.09034390 205.00 -7.53438679e-02 -2.31692729e-01 2.43635422e-01 -1.88519893 0.03990775 205.25 -1.17864435e-01 -2.04268623e-01 2.35834042e-01 -2.09413765 0.02803427 205.50 -3.03749067e-01 -3.01070830e-01 4.27676443e-01 -2.36062262 0.09319049 205.75 -3.13505096e-01 -2.38251223e-01 3.93762733e-01 -2.49174778 0.07388114 206.00 -3.27812238e-01 8.24687034e-02 3.38026553e-01 2.89513408 0.07687317 206.25 -3.39818165e-01 6.80089909e-02 3.46556789e-01 2.94406875 0.07765607 206.50 -2.59232072e-01 -1.66652106e-01 3.08178831e-01 -2.57024721 0.07834437 206.75 -3.69067547e-01 5.36505739e-02 3.72946696e-01 2.99723593 0.08417081 207.00 -5.29753822e-01 9.10047646e-02 5.37513701e-01 2.97146631 0.24557400 207.25 -4.54334646e-01 6.39283547e-02 4.58810206e-01 3.00180275 0.14782524 207.50 -5.27354321e-01 1.02584330e-01 5.37239355e-01 2.94946568 0.18381815 207.75 -4.53629571e-01 7.04564897e-02 4.59068519e-01 2.98750658 0.11819445 208.00 -4.76941448e-01 2.56452111e-01 5.41517156e-01 2.64824071 0.15709646 208.25 -2.01999705e-01 1.74616395e-01 2.67010798e-01 2.42877558 0.02633537 208.50 -1.61280543e-01 1.10538713e-01 1.95525499e-01 2.54074524 0.01677735 208.75 5.05440124e-02 8.11625805e-03 5.11915113e-02 0.15921882 0.00078579 209.00 -2.06979971e-02 -1.81723651e-01 1.82898585e-01 -1.68420580 0.00679572 209.25 1.45164753e-01 3.22858885e-02 1.48711749e-01 0.21884654 0.00369916 209.50 2.01588422e-01 1.15064903e-01 2.32115971e-01 0.51866552 0.00931784 209.75 4.11948175e-02 1.57957729e-01 1.63241101e-01 1.31568238 0.00404197 210.00 -3.75718577e-01 1.68071854e-01 4.11597616e-01 2.72095763 0.01987186 210.25 1.03926654e-01 -1.35074656e-01 1.70428613e-01 -0.91499340 0.00261555 210.50 4.05498012e-01 1.54033986e-01 4.33768494e-01 0.36302793 0.01775215 210.75 4.99499497e-01 2.89480499e-01 5.77320281e-01 0.52524036 0.03616833 211.00 5.75106469e-01 2.81190726e-01 6.40168474e-01 0.45475796 0.04829513 211.25 4.31134516e-01 9.00701679e-02 4.40442512e-01 0.20595213 0.01554177 211.50 4.76155086e-01 3.44039658e-01 5.87441020e-01 0.62569187 0.03358058 211.75 4.24759158e-01 3.53005315e-01 5.52298013e-01 0.69340205 0.04157608 212.00 3.19937787e-01 1.80706450e-01 3.67443885e-01 0.51414817 0.02058046 212.25 7.36374948e-01 1.71093228e-01 7.55990050e-01 0.22829467 0.08110542 212.50 7.60086657e-01 3.64891692e-02 7.60962013e-01 0.04796976 0.09297760 212.75 5.15998030e-01 9.04955411e-02 5.23873468e-01 0.17361399 0.04056223 213.00 5.50489421e-01 2.52971869e-01 6.05832789e-01 0.43075895 0.06066962 213.25 4.56321696e-01 3.55755776e-01 5.78611841e-01 0.66218761 0.04484333 213.50 5.54763023e-01 1.03056034e-01 5.64253983e-01 0.18367219 0.04511756 213.75 6.74905933e-02 8.79689427e-02 1.10876125e-01 0.91637192 0.00153067 214.00 3.19227989e-01 -9.50223510e-02 3.33070197e-01 -0.28931135 0.01525114 214.25 3.48874292e-01 2.84136983e-01 4.49941215e-01 0.68348367 0.03284381 214.50 4.36515563e-01 1.55276461e-01 4.63310496e-01 0.34175973 0.03414217 214.75 -1.02975322e-01 8.51169778e-02 1.33599464e-01 2.45085531 0.00312616 215.00 -1.94431064e-01 1.56157299e-02 1.95057144e-01 3.06144968 0.00660642 215.25 2.41503651e-01 -4.03135002e-01 4.69938127e-01 -1.03106537 0.03683361 215.50 4.24332920e-01 -1.72434065e-01 4.58030495e-01 -0.38598141 0.03511122 215.75 6.99973963e-01 1.53113238e-01 7.16524398e-01 0.21534943 0.07300988 216.00 7.95010486e-01 1.88623257e-01 8.17080416e-01 0.23295149 0.10038277 216.25 8.09493852e-01 3.56337652e-01 8.84452835e-01 0.41467283 0.14782661 216.50 6.93110029e-01 3.63851295e-01 7.82808582e-01 0.48341141 0.10743809 216.75 2.57365413e-01 2.33983492e-01 3.47829312e-01 0.73784683 0.02445140 217.00 6.05671179e-01 2.35350065e-01 6.49790143e-01 0.37062059 0.08014022 217.25 6.04386672e-01 5.30666963e-01 8.04295142e-01 0.72054104 0.14108340 217.50 2.61132675e-01 6.15116348e-01 6.68250249e-01 1.16932752 0.08026447 217.75 7.65003066e-03 1.25243116e+00 1.25245452e+00 1.56468826 0.34355443 218.00 7.70365769e-02 1.06136569e+00 1.06415777e+00 1.49834088 0.20528045 218.25 3.62444085e-02 9.54885744e-01 9.55573357e-01 1.53285774 0.19449521 218.50 -4.15919454e-03 1.28703524e+00 1.28704196e+00 1.57402792 0.27219211 218.75 -3.42246239e-01 1.45809548e+00 1.49772324e+00 1.80134427 0.41695642 219.00 -4.11692925e-01 1.61724726e+00 1.66882587e+00 1.82006588 0.46358758 219.25 -5.53328961e-01 1.88790354e+00 1.96732121e+00 1.85590329 0.61813674 219.50 -2.28081505e-01 2.18162504e+00 2.19351521e+00 1.67496452 0.66720509 219.75 -2.40128040e-01 2.17718020e+00 2.19038241e+00 1.68064548 0.73159874 220.00 9.64955628e-02 2.38289873e+00 2.38485173e+00 1.53032341 0.70131129 220.25 4.73038239e-01 2.53396319e+00 2.57773828e+00 1.38624141 0.71288838 220.50 8.88512327e-01 1.81611426e+00 2.02181235e+00 1.11579523 0.56120324 220.75 1.37394410e+00 1.12623072e+00 1.77654665e+00 0.68664205 0.53480509 221.00 1.44594429e+00 1.78254693e-01 1.45689039e+00 0.12266020 0.44696522 221.25 9.71080121e-01 -3.26348907e-01 1.02445118e+00 -0.32420969 0.34082179 221.50 -6.78291394e-02 -2.83594841e-01 2.91593597e-01 -1.80556224 0.05191352 221.75 -3.88174332e-01 1.01666075e-01 4.01267122e-01 2.88543797 0.13289803 222.00 -2.14850489e-01 4.44286187e-01 4.93508813e-01 2.02122656 0.24805205 222.25 -2.60489142e-01 4.69432754e-01 5.36862835e-01 2.07739523 0.33452439 222.50 -5.66237319e-01 5.16846451e-01 7.66651782e-01 2.40176499 0.60414368 222.75 -6.00761175e-01 5.40393538e-01 8.08046512e-01 2.40904571 0.65555821 223.00 -6.14140287e-01 8.98052007e-01 1.08796402e+00 2.17060656 0.73719918 223.25 -6.61280735e-01 9.41517731e-01 1.15054242e+00 2.18310183 0.77645993 223.50 -7.58319779e-01 1.01262293e+00 1.26509054e+00 2.21357185 0.78474640 223.75 -7.10999492e-01 1.15045508e+00 1.35243010e+00 2.12435757 0.78920607 224.00 -6.92141463e-01 9.32795174e-01 1.16153633e+00 2.20916289 0.70347300 224.25 -7.39764815e-01 9.56205940e-01 1.20895897e+00 2.22925986 0.71359333 224.50 -8.35382374e-01 1.23643981e+00 1.49219540e+00 2.16498231 0.73178813 224.75 -7.36801910e-01 1.45231907e+00 1.62852932e+00 2.04028901 0.75891083 225.00 -2.83664634e-01 1.35047572e+00 1.37994576e+00 1.77783443 0.76748450 225.25 -1.32409765e-01 1.27240066e+00 1.27927159e+00 1.67448606 0.70003900 225.50 -3.21118037e-01 1.02385843e+00 1.07303443e+00 1.87471506 0.63017631 225.75 -2.60762524e-01 8.79595860e-01 9.17434450e-01 1.85899968 0.49808467 226.00 -2.43850583e-01 9.86306969e-01 1.01600420e+00 1.81317188 0.64089174 226.25 -3.03489594e-01 9.18255046e-01 9.67108196e-01 1.89000090 0.58210178 226.50 -4.50599117e-01 1.11875610e+00 1.20609070e+00 1.95368660 0.60101358 226.75 -2.71335325e-01 1.15464637e+00 1.18609911e+00 1.80160289 0.45563884 227.00 1.16929403e-01 8.88931608e-01 8.96589030e-01 1.44000795 0.16337439 227.25 9.40843592e-03 1.44477546e-01 1.44783562e-01 1.50576774 0.00274851 227.50 -1.26038626e+00 -5.91008340e-02 1.26177115e+00 -3.09473593 0.18445556 227.75 -1.32959851e+00 4.97424285e-01 1.41959963e+00 2.78359708 0.22810550 228.00 -1.44648904e+00 1.38113906e+00 1.99996891e+00 2.37930161 0.56649007 228.25 -1.09260953e+00 1.27581078e+00 1.67972877e+00 2.27899655 0.53116294 228.50 -8.94753979e-01 1.00869001e+00 1.34834722e+00 2.29640799 0.60515618 228.75 -7.49936903e-01 1.00995957e+00 1.25794423e+00 2.20950689 0.51572316 229.00 -9.89229740e-01 9.56974286e-01 1.37636306e+00 2.37276649 0.66004791 229.25 -1.00170940e+00 1.01786128e+00 1.42809780e+00 2.34819698 0.59596115 229.50 -1.05056684e+00 1.25353155e+00 1.63555251e+00 2.26833272 0.57589781 229.75 -8.62835259e-01 1.08174768e+00 1.38371338e+00 2.24409096 0.30191114 230.00 -4.78168142e-01 1.29072640e+00 1.37645174e+00 1.92558464 0.23434891 230.25 -2.83261026e-01 1.18565307e+00 1.21902010e+00 1.80530775 0.21914618 230.50 -2.04190331e-01 1.31999633e+00 1.33569607e+00 1.72426996 0.30777364 230.75 -1.13482604e-01 1.31357346e+00 1.31846636e+00 1.65697463 0.39839980 231.00 -9.24584684e-02 1.32568574e+00 1.32890603e+00 1.64042745 0.55821658 231.25 -1.80873622e-01 1.03021341e+00 1.04597081e+00 1.74459411 0.40073163 231.50 -1.13284416e-01 1.08310775e+00 1.08901595e+00 1.67500943 0.41602146 231.75 -1.92805888e-01 1.11527312e+00 1.13181634e+00 1.74198205 0.41953290 232.00 -3.45698353e-01 1.06500085e+00 1.11970271e+00 1.88466561 0.46992572 232.25 -2.83179700e-01 9.44991155e-01 9.86508502e-01 1.86194471 0.32831265 232.50 -2.98545772e-01 1.00329630e+00 1.04677268e+00 1.86001760 0.36220329 232.75 -5.58740342e-01 1.03197548e+00 1.17352638e+00 2.06703448 0.50045360 233.00 -6.69788969e-01 1.02244324e+00 1.22229598e+00 2.15073913 0.54510932 233.25 -4.43066192e-01 8.93156769e-01 9.97013874e-01 2.03129312 0.31221784 233.50 -4.70188143e-01 6.89730785e-01 8.34748732e-01 2.16913322 0.26453448 233.75 -5.23025745e-01 7.78737137e-01 9.38076467e-01 2.16222945 0.32385688 234.00 -6.51309890e-01 8.39810512e-01 1.06277292e+00 2.23044609 0.30352739 234.25 -7.22772111e-01 7.28009862e-01 1.02586446e+00 2.35258421 0.23387517 234.50 -7.83448743e-01 7.14958504e-01 1.06064018e+00 2.40187139 0.28351907 234.75 -1.21738170e+00 1.02796512e+00 1.59333941e+00 2.44035484 0.49195591 235.00 -1.26078847e+00 9.29250855e-01 1.56623584e+00 2.50643802 0.41382577 235.25 -9.56268331e-01 6.44512970e-01 1.15318953e+00 2.54853884 0.25149854 235.50 -1.05085636e+00 4.64573736e-01 1.14896817e+00 2.72533561 0.22569597 235.75 -1.00210447e+00 7.46613520e-01 1.24965800e+00 2.50126991 0.26800598 236.00 -7.35585267e-01 8.05029496e-01 1.09048529e+00 2.31114932 0.28259879 236.25 -7.14277327e-01 7.27905708e-01 1.01982294e+00 2.34674494 0.34097579 236.50 -8.14654779e-01 4.01705291e-01 9.08311372e-01 2.68348123 0.26210514 236.75 -1.05792156e+00 2.57360142e-01 1.08877558e+00 2.90295846 0.39093443 237.00 -9.58762181e-01 8.75691774e-02 9.62752969e-01 3.05050971 0.37840946 237.25 -8.67903208e-01 2.37975336e-02 8.68229406e-01 3.11417995 0.54402639 237.50 -7.87513375e-01 -1.50750728e-01 8.01812383e-01 -2.95245452 0.53826574 237.75 -6.71891121e-01 -4.32330930e-01 7.98966653e-01 -2.56983307 0.69440421 238.00 -5.65889616e-01 -5.35268027e-01 7.78937043e-01 -2.38399587 0.68271254 238.25 -4.67349176e-01 -6.04565825e-01 7.64143369e-01 -2.22887617 0.74021367 238.50 -3.26992917e-01 -6.23877684e-01 7.04377550e-01 -2.05356095 0.67865653 238.75 -2.30749259e-01 -5.77952425e-01 6.22313608e-01 -1.95065860 0.75053776 239.00 -1.10502547e-01 -5.81992901e-01 5.92390538e-01 -1.75843206 0.65814351 239.25 4.84510476e-02 -5.06686434e-01 5.08997688e-01 -1.47546286 0.68293311 239.50 1.48379574e-01 -5.13881278e-01 5.34874253e-01 -1.28969887 0.64113782 239.75 2.63135089e-01 -4.88668802e-01 5.55011057e-01 -1.07684586 0.63720892 240.00 3.72866867e-01 -5.13887210e-01 6.34909257e-01 -0.94310732 0.64609289 240.25 4.88257710e-01 -5.03003654e-01 7.01005184e-01 -0.80027301 0.77953095 240.50 6.16060276e-01 -4.81242376e-01 7.81744516e-01 -0.66314784 0.72002124 240.75 7.04766165e-01 -5.81458804e-01 9.13668260e-01 -0.68982260 0.74539301 241.00 9.62802444e-01 -5.59284060e-01 1.11345732e+00 -0.52625086 0.76219056 241.25 1.03647203e+00 -6.02416389e-01 1.19882433e+00 -0.52649485 0.77335201 241.50 1.07771146e+00 -7.44127245e-01 1.30965161e+00 -0.60430120 0.73511981 241.75 1.19195996e+00 -8.16792939e-01 1.44496341e+00 -0.60075925 0.74635322 242.00 1.21057833e+00 -1.23631999e+00 1.73031413e+00 -0.79591789 0.76664671 242.25 9.71546077e-01 -1.58452806e+00 1.85866375e+00 -1.02076713 0.77396830 242.50 8.71377399e-01 -1.96203508e+00 2.14683028e+00 -1.15284365 0.81072038 242.75 7.68310306e-01 -2.30103862e+00 2.42591827e+00 -1.24853840 0.85403464 243.00 3.25730369e-01 -2.79327847e+00 2.81220641e+00 -1.45470843 0.80152344 243.25 -7.73605671e-03 -2.83739059e+00 2.83740113e+00 -1.57352279 0.74093095 243.50 -7.19991777e-01 -1.93936349e+00 2.06869981e+00 -1.92627668 0.61548984 243.75 -9.16966431e-01 -1.62985957e+00 1.87009883e+00 -2.08326521 0.53219206 244.00 -1.41574356e+00 -1.32428424e+00 1.93857127e+00 -2.38956108 0.48085819 244.25 -1.81537247e+00 -1.08289022e+00 2.11381844e+00 -2.60374231 0.49114192 244.50 -2.11159926e+00 -5.52550813e-01 2.18269646e+00 -2.88565715 0.50508150 244.75 -1.95799201e+00 -6.83906770e-02 1.95918606e+00 -3.10667786 0.45183850 245.00 -1.46700630e+00 1.00232333e+00 1.77672720e+00 2.54220103 0.48574268 245.25 -1.13456112e+00 1.04758484e+00 1.54423539e+00 2.39603154 0.50024097 245.50 -5.10819587e-01 1.03975445e+00 1.15845845e+00 2.02745062 0.51197133 245.75 -3.70797058e-01 9.02465927e-01 9.75671670e-01 1.96063897 0.45593463 246.00 -3.19623011e-02 8.12575900e-01 8.13204268e-01 1.61011060 0.41221645 246.25 -1.10336414e-01 7.86088247e-01 7.93793963e-01 1.71024666 0.35434109 246.50 1.56362994e-02 4.19783859e-01 4.20074972e-01 1.53356509 0.17493289 246.75 3.93271610e-02 3.66173281e-01 3.68279102e-01 1.46380603 0.11613271 247.00 5.81418025e-02 4.34438436e-01 4.38311788e-01 1.43775478 0.16914809 247.25 1.39231222e-01 3.86430280e-01 4.10747727e-01 1.22497429 0.11726557 247.50 3.93927360e-01 1.78645737e-01 4.32542558e-01 0.42576004 0.11377919 247.75 3.40954280e-01 1.31081705e-01 3.65283772e-01 0.36703443 0.07922052 248.00 2.21780380e-01 2.16681982e-01 3.10060669e-01 0.77377078 0.05914858 248.25 3.57985331e-01 1.13629927e-01 3.75586552e-01 0.30735634 0.06514457 248.50 2.22000728e-01 -6.56845836e-02 2.31514120e-01 -0.28766860 0.01824471 248.75 2.15557294e-01 2.07325589e-01 2.99080000e-01 0.76593494 0.03102736 249.00 1.66459385e-01 -1.31267362e-01 2.11990205e-01 -0.66774167 0.01974407 249.25 1.07851919e-01 -1.62636849e-01 1.95148101e-01 -0.98523531 0.01398631 249.50 2.67253086e-01 -3.97919114e-01 4.79336868e-01 -0.97936774 0.08802040 249.75 2.28609799e-01 -4.39506364e-01 4.95407190e-01 -1.09115796 0.04442018 250.00 3.50488759e-01 -1.81037695e-01 3.94483228e-01 -0.47678340 0.01185125 250.25 -1.53174142e-01 -2.22810552e-01 2.70382802e-01 -2.17305895 0.00883333 250.50 -4.15782785e-01 -2.94134466e-01 5.09303847e-01 -2.52590191 0.06777018 250.75 -5.50882595e-01 -1.70042732e-01 5.76529413e-01 -2.84219785 0.08941918 251.00 -4.51728375e-01 -1.23938490e-02 4.51898365e-01 -3.11416303 0.04945587 251.25 -3.24953913e-01 -6.16195976e-02 3.30744645e-01 -2.95419204 0.02791227 251.50 -4.64621820e-01 1.53650518e-01 4.89368897e-01 2.82221381 0.07401196 251.75 -1.14093123e-01 1.46180300e-01 1.85434411e-01 2.23353085 0.01904923 252.00 1.69293398e-01 5.17220648e-02 1.77018153e-01 0.29651084 0.02323430 252.25 2.49463757e-01 -6.19027494e-02 2.57029408e-01 -0.24323038 0.03818473 252.50 -1.28214310e-02 -2.78314519e-01 2.78609692e-01 -1.61683191 0.05285758 252.75 -4.78498661e-01 -5.72981216e-01 7.46504148e-01 -2.26657843 0.32700580 253.00 -6.02972813e-01 -6.76461185e-01 9.06187590e-01 -2.29881934 0.49134506 253.25 -8.05420519e-01 -5.68641807e-01 9.85928860e-01 -2.52683882 0.46456444 253.50 -1.00416415e+00 -5.48293009e-01 1.14410265e+00 -2.64181078 0.53291847 253.75 -1.06663228e+00 -2.59430121e-02 1.06694773e+00 -3.11727509 0.47226045 254.00 -1.13114210e+00 3.14029753e-02 1.13157792e+00 3.11383760 0.56228351 254.25 -1.13878389e+00 1.74872342e-01 1.15213241e+00 2.98922229 0.60836812 254.50 -1.13356279e+00 1.97945415e-01 1.15071586e+00 2.96871342 0.62250700 254.75 -1.02224675e+00 2.05960599e-01 1.04278866e+00 2.94277600 0.50132191 255.00 -8.60407643e-01 2.47198132e-01 8.95214068e-01 2.86182433 0.45070739 255.25 -9.51446314e-01 4.71545453e-01 1.06188757e+00 2.68146393 0.44158815 255.50 -9.44570805e-01 5.52504261e-01 1.09429199e+00 2.61233053 0.40952820 255.75 -9.87859362e-01 5.43655268e-01 1.12757579e+00 2.63849097 0.41508998 256.00 -1.08540088e+00 5.68334095e-01 1.22519334e+00 2.65923063 0.46708011 256.25 -8.06998493e-01 7.43933796e-01 1.09758100e+00 2.39683455 0.31881846 256.50 -8.32212962e-01 6.62816398e-01 1.06390977e+00 2.46901981 0.25026292 256.75 -1.17497365e+00 1.41477696e+00 1.83906415e+00 2.26386072 0.48598013 257.00 -5.62582756e-01 1.64828651e+00 1.74165088e+00 1.89971193 0.50085815 257.25 -1.77516103e-01 1.44800946e+00 1.45885002e+00 1.69278084 0.64529649 257.50 -3.33983191e-02 1.35921491e+00 1.35962517e+00 1.59536316 0.63302214 257.75 1.24188923e-01 1.18413752e+00 1.19063200e+00 1.46630122 0.60079720 258.00 1.03550964e-01 1.10405963e+00 1.10890508e+00 1.47727881 0.65479681 258.25 2.89011812e-01 1.08541087e+00 1.12322953e+00 1.31056477 0.76566804 258.50 3.43748760e-01 8.98930919e-01 9.62413636e-01 1.20555617 0.64475523 258.75 2.49742956e-01 6.89409620e-01 7.33251095e-01 1.22324478 0.56399988 259.00 1.73816196e-01 6.50388344e-01 6.73213983e-01 1.30964954 0.53484350 259.25 4.05563762e-02 5.89284791e-01 5.90678749e-01 1.50208163 0.47297717 259.50 -2.04427905e-02 5.46182545e-01 5.46564982e-01 1.60820736 0.38121625 259.75 -2.05256038e-02 4.43661218e-01 4.44135764e-01 1.61702750 0.31198091 260.00 -3.03277199e-02 5.35144311e-01 5.36002989e-01 1.62740781 0.34570338 260.25 -2.04981918e-02 4.71222084e-01 4.71667710e-01 1.61426899 0.31545173 260.50 -4.35142299e-02 6.05194725e-01 6.06757072e-01 1.64257401 0.34922616 260.75 -1.57059171e-01 6.75064140e-01 6.93093916e-01 1.79938784 0.47089129 261.00 -8.47920597e-02 6.15681405e-01 6.21492789e-01 1.70765606 0.36738060 261.25 -6.07459733e-02 7.53164709e-01 7.55610450e-01 1.65127642 0.54884787 261.50 6.17648275e-02 9.52305710e-01 9.54306585e-01 1.50602885 0.57119942 261.75 3.08853362e-01 1.04955186e+00 1.09405188e+00 1.28460315 0.62456807 262.00 5.56114230e-01 8.49961168e-01 1.01572488e+00 0.99141685 0.57760391 262.25 5.90631799e-01 6.62867279e-01 8.87828222e-01 0.84296157 0.60919076 262.50 4.39989153e-01 5.43613068e-01 6.99360866e-01 0.89036242 0.59520592 262.75 3.98224461e-01 5.37438554e-01 6.68896794e-01 0.93310117 0.67809892 263.00 2.80648956e-01 4.09732554e-01 4.96633268e-01 0.97023822 0.46798947 263.25 2.51965189e-01 3.70934531e-01 4.48418200e-01 0.97411811 0.44718416 263.50 2.62944320e-01 2.88021781e-01 3.89995208e-01 0.83088220 0.36955386 263.75 2.29506855e-01 3.07675929e-01 3.83846159e-01 0.92990062 0.44249542 264.00 1.95633444e-01 3.84251093e-01 4.31185977e-01 1.09987207 0.55229879 264.25 2.09233610e-01 3.74047634e-01 4.28591106e-01 1.06078247 0.57422754 264.50 2.89478070e-01 3.71949556e-01 4.71321573e-01 0.90944505 0.46325794 264.75 2.22790508e-01 3.47926289e-01 4.13144422e-01 1.00124322 0.46130512 265.00 2.85307996e-01 2.98432836e-01 4.12871421e-01 0.80787839 0.49129169 265.25 2.47778008e-01 3.27370647e-01 4.10567269e-01 0.92291098 0.46893621 265.50 3.37096654e-01 2.46542474e-01 4.17633027e-01 0.63147109 0.50942222 265.75 3.46544756e-01 2.65638237e-01 4.36642807e-01 0.65399898 0.53801722 266.00 2.47574026e-01 2.24616771e-01 3.34283700e-01 0.73681782 0.42100270 266.25 2.77528427e-01 2.35215580e-01 3.63797192e-01 0.70306236 0.49225742 266.50 2.17906819e-01 2.60664499e-01 3.39748970e-01 0.87450599 0.38239786 266.75 2.47105880e-01 2.79563739e-01 3.73118212e-01 0.84694882 0.38823266 267.00 2.06919686e-01 3.08484755e-01 3.71454709e-01 0.97996422 0.42094537 267.25 2.11491424e-01 2.79049979e-01 3.50139277e-01 0.92225962 0.37455677 267.50 2.57335238e-01 2.25105094e-01 3.41897248e-01 0.71869080 0.39372066 267.75 2.85965779e-01 2.33618954e-01 3.69261753e-01 0.68498954 0.27911382 268.00 3.13061847e-01 1.38481346e-01 3.42322659e-01 0.41646983 0.24133093 268.25 2.96084369e-01 1.57046231e-01 3.35155892e-01 0.48767893 0.24012922 268.50 6.01534010e-02 9.97563584e-02 1.16489324e-01 1.02817153 0.04288933 268.75 -3.22924245e-02 1.47499815e-01 1.50993364e-01 1.78632768 0.05081360 269.00 -1.21602652e-01 1.35223304e-01 1.81858591e-01 2.30320957 0.09231762 269.25 -1.10854164e-02 3.70250134e-01 3.70416047e-01 1.60072773 0.25526175 269.50 9.94220773e-03 6.52191163e-01 6.52266940e-01 1.55555319 0.60585538 269.75 1.35890066e-01 6.26416718e-01 6.40986751e-01 1.35717391 0.51271942 270.00 1.78453339e-01 6.46883798e-01 6.71047124e-01 1.30162505 0.57892859 270.25 3.61830915e-01 6.65500057e-01 7.57503754e-01 1.07280453 0.55440042 270.50 4.93216894e-01 6.49122388e-01 8.15244000e-01 0.92103928 0.59875644 270.75 6.73033145e-01 6.72272109e-01 9.51274620e-01 0.78483247 0.64812258 271.00 7.98224406e-01 7.77257310e-01 1.11413246e+00 0.77209058 0.78292045 271.25 9.46698367e-01 4.10339936e-01 1.03180263e+00 0.40900029 0.57404093 271.50 1.43309355e+00 1.18883471e-01 1.43801614e+00 0.08276632 0.76242434 271.75 1.72596184e+00 -1.89826984e-01 1.73636936e+00 -0.10954303 0.77839649 272.00 1.84807669e+00 -4.34100619e-01 1.89837583e+00 -0.23071073 0.83923256 272.25 1.48628204e+00 -1.17340664e+00 1.89365188e+00 -0.66830023 0.73993738 272.50 1.11074015e+00 -1.76566378e+00 2.08597993e+00 -1.00926993 0.78715494 272.75 5.80829608e-01 -2.17826553e+00 2.25437436e+00 -1.31021159 0.80303309 273.00 8.06770430e-02 -2.18494066e+00 2.18642962e+00 -1.53388896 0.77703858 273.25 -8.69184094e-01 -1.74168282e+00 1.94651998e+00 -2.03368240 0.74734334 273.50 -1.13617279e+00 -1.58263505e+00 1.94823569e+00 -2.19343459 0.84276980 273.75 -1.28644430e+00 -9.64880180e-01 1.60808355e+00 -2.49806818 0.78910957 274.00 -1.40701108e+00 -8.49569294e-01 1.64360827e+00 -2.59837538 0.85674793 274.25 -1.19138432e+00 -5.02437389e-01 1.29299649e+00 -2.74249863 0.78345055 274.50 -1.22673910e+00 -3.63628818e-01 1.27949785e+00 -2.85342438 0.81638051 274.75 -1.20405379e+00 -1.15753527e-01 1.20960507e+00 -3.04575069 0.79427553 275.00 -1.13320079e+00 5.40569473e-02 1.13448940e+00 3.09392590 0.78242437 275.25 -1.14579228e+00 2.09576427e-01 1.16480136e+00 2.96068285 0.72545442 275.50 -1.06589925e+00 2.78236008e-01 1.10161539e+00 2.88625626 0.72891122 275.75 -1.03421961e+00 4.14223780e-01 1.11408776e+00 2.76063963 0.64563746 276.00 -1.05658982e+00 5.27219688e-01 1.18082287e+00 2.67875948 0.65915846 276.25 -8.21742414e-01 6.07987859e-01 1.02220831e+00 2.50460216 0.63430460 276.50 -7.16375798e-01 6.14869629e-01 9.44065117e-01 2.43229626 0.56296901 276.75 -4.07473690e-01 8.13523982e-01 9.09865966e-01 2.03514356 0.54007910 277.00 -2.61601623e-01 8.18832098e-01 8.59605383e-01 1.88002877 0.50973207 277.25 -2.65424600e-01 7.99358450e-01 8.42273204e-01 1.89138876 0.48715579 277.50 -2.03765979e-01 8.91623279e-01 9.14610652e-01 1.79547165 0.60005083 277.75 -1.17371141e-01 7.59288435e-01 7.68306522e-01 1.72416289 0.55728538 278.00 4.40678307e-02 6.73045058e-01 6.74486192e-01 1.50541435 0.45062288 278.25 1.29008930e-01 8.00309379e-01 8.10640738e-01 1.41097238 0.63489301 278.50 2.15431376e-01 8.06277837e-01 8.34562537e-01 1.30970309 0.67631794 278.75 3.12530308e-01 9.47562233e-01 9.97772208e-01 1.25220602 0.77302060 279.00 4.83532120e-01 7.75488290e-01 9.13884785e-01 1.01326230 0.64861290 279.25 6.07955104e-01 4.02593369e-01 7.29171331e-01 0.58491021 0.75597511 279.50 4.98924535e-01 3.57382569e-01 6.13716541e-01 0.62158587 0.65899154 279.75 3.39992351e-01 2.64996188e-01 4.31065863e-01 0.66206439 0.65477643 280.00 2.73377831e-01 1.66850984e-01 3.20272836e-01 0.54798126 0.42579915 280.25 2.24648116e-01 1.26748653e-01 2.57937971e-01 0.51368730 0.47466398 280.50 1.98416407e-01 1.50774177e-01 2.49202574e-01 0.64979923 0.42907523 280.75 1.48939178e-01 1.69277464e-01 2.25472257e-01 0.84922468 0.43704660 281.00 1.66317150e-01 1.63810193e-01 2.33442013e-01 0.77780440 0.38911955 281.25 2.00877527e-01 1.66630122e-01 2.60993062e-01 0.69247824 0.47734802 281.50 1.27117604e-01 1.76113684e-01 2.17197871e-01 0.94559350 0.40184566 281.75 1.00865331e-01 1.70868154e-01 1.98418097e-01 1.03753164 0.44522322 282.00 9.89067689e-02 1.82352408e-01 2.07448668e-01 1.07381176 0.34377140 282.25 9.69965704e-02 1.77415822e-01 2.02199675e-01 1.07047574 0.42965383 282.50 1.02244021e-01 1.87765360e-01 2.13798200e-01 1.07216181 0.40189197 282.75 8.84291054e-02 2.00539738e-01 2.19170923e-01 1.15548919 0.50220808 283.00 7.58356218e-02 2.64292711e-01 2.74957594e-01 1.29136568 0.54070313 283.25 8.57880009e-02 2.74338621e-01 2.87439141e-01 1.26772158 0.64993588 283.50 1.13314879e-01 2.86935929e-01 3.08500388e-01 1.19468252 0.63374666 283.75 1.62814235e-01 3.04433696e-01 3.45236658e-01 1.07968992 0.70223910 284.00 1.83344668e-01 3.07571007e-01 3.58071489e-01 1.03324559 0.67511071 284.25 2.27054818e-01 2.65798228e-01 3.49574869e-01 0.86384730 0.68052269 284.50 2.88310631e-01 2.83456333e-01 4.04314868e-01 0.77690837 0.71557650 284.75 2.95628615e-01 2.86136556e-01 4.11424850e-01 0.76908365 0.73729075 285.00 3.14989579e-01 1.77554540e-01 3.61585466e-01 0.51328831 0.71511566 285.25 3.22333076e-01 1.43255464e-01 3.52733242e-01 0.41821479 0.77386001 285.50 3.09874894e-01 1.10190790e-01 3.28883657e-01 0.34165288 0.77129452 285.75 2.76418016e-01 1.08959327e-01 2.97117913e-01 0.37548182 0.76803936 286.00 2.79126525e-01 3.70587423e-02 2.81575864e-01 0.13199488 0.75912343 286.25 2.52007486e-01 2.70369564e-02 2.53453684e-01 0.10687751 0.68659360 286.50 2.64981919e-01 2.23970018e-02 2.65926763e-01 0.08432233 0.74436264 286.75 2.51539915e-01 2.67322549e-02 2.52956403e-01 0.10587700 0.72155912 287.00 2.12411405e-01 -1.52067611e-03 2.12416848e-01 -0.00715899 0.70821568 287.25 2.11140456e-01 1.52016250e-03 2.11145928e-01 0.00719964 0.71024718 287.50 2.04402864e-01 2.89415838e-03 2.04423353e-01 0.01415814 0.69240278 287.75 2.17830993e-01 3.51788707e-03 2.17859398e-01 0.01614821 0.67365443 288.00 2.10929666e-01 -2.19191127e-02 2.12065488e-01 -0.10354504 0.65536147 288.25 2.04736189e-01 -3.06218232e-02 2.07013534e-01 -0.14846667 0.64044007 288.50 2.10593620e-01 -5.03963237e-02 2.16539747e-01 -0.23488871 0.72260436 288.75 1.98943478e-01 -6.13818428e-02 2.08197594e-01 -0.29927231 0.66918816 289.00 1.69470237e-01 -4.73124857e-02 1.75950653e-01 -0.27224698 0.58222617 289.25 1.64733000e-01 -5.64506005e-02 1.74136819e-01 -0.33013827 0.49199404 289.50 1.60331141e-01 -3.70007463e-02 1.64545221e-01 -0.22680626 0.66022925 289.75 1.58493983e-01 -5.27755940e-02 1.67049711e-01 -0.32143404 0.61696972 290.00 1.33782446e-01 -5.91239940e-02 1.46264793e-01 -0.41613217 0.55689335 290.25 1.37230527e-01 -5.66623708e-02 1.48468319e-01 -0.39157666 0.46804943 290.50 1.47736547e-01 -1.02972108e-01 1.80081488e-01 -0.60870849 0.53248225 290.75 1.44196104e-01 -1.11960513e-01 1.82558683e-01 -0.66021294 0.52587815 291.00 1.46570992e-01 -1.08415942e-01 1.82310373e-01 -0.63686490 0.59290619 291.25 1.27001596e-01 -1.08553496e-01 1.67072639e-01 -0.70724014 0.43980224 291.50 8.84045876e-02 -1.28076481e-01 1.55624407e-01 -0.96664508 0.44939379 291.75 6.64096736e-02 -1.30639662e-01 1.46550217e-01 -1.10049713 0.35155699 292.00 6.02025781e-02 -1.20033308e-01 1.34284569e-01 -1.10591034 0.38422015 292.25 4.82168545e-02 -1.29473217e-01 1.38159976e-01 -1.21430008 0.37408934 292.50 3.02500218e-02 -1.42397051e-01 1.45574668e-01 -1.36147377 0.43922158 292.75 9.30036047e-03 -1.36988355e-01 1.37303700e-01 -1.50300874 0.34223152 293.00 -1.92708414e-02 -1.49500529e-01 1.50737432e-01 -1.69899093 0.37687428 293.25 -4.61122351e-02 -1.00445308e-01 1.10524197e-01 -2.00117386 0.18893880 293.50 -6.52462041e-02 -7.97241082e-02 1.03019418e-01 -2.25665647 0.19856610 293.75 -4.59461253e-02 -1.88260556e-02 4.96534671e-02 -2.75271635 0.03862030 294.00 -5.70767831e-02 7.97652052e-03 5.76314502e-02 3.00274123 0.05229252 294.25 -6.94308964e-02 -2.25659707e-02 7.30059752e-02 -2.82734865 0.06611385 294.50 -4.73205715e-02 3.99576585e-02 6.19342471e-02 2.44035660 0.05104096 294.75 -1.36175733e-02 3.16976467e-02 3.44989726e-02 1.97656379 0.01445866 295.00 1.01451241e-02 1.94554999e-02 2.19417415e-02 1.09013417 0.00638058 295.25 2.35228377e-02 3.61997220e-02 4.31710987e-02 0.99455670 0.02153642 295.50 1.22874712e-02 4.72284840e-02 4.88007341e-02 1.31626831 0.03574563 295.75 4.00074736e-02 6.34258648e-02 7.49895877e-02 1.00805471 0.08617111 296.00 5.57261434e-02 5.86267621e-02 8.08857237e-02 0.81075823 0.10452751 296.25 6.70824095e-02 1.25304842e-02 6.82426751e-02 0.18466429 0.06813746 296.50 7.51343911e-02 3.14585666e-02 8.14543930e-02 0.39652011 0.10687514 296.75 6.95433868e-02 6.88853629e-02 9.78850135e-02 0.78064468 0.15366488 297.00 7.30217757e-02 4.69724118e-02 8.68250378e-02 0.57162659 0.13153657 297.25 7.50468157e-02 1.65365574e-02 7.68471357e-02 0.21688402 0.12368573 297.50 7.41073935e-02 1.21635131e-02 7.50989802e-02 0.16268306 0.11334745 297.75 1.10948876e-01 -1.66859054e-04 1.10949002e-01 -0.00150393 0.23463191 298.00 1.12168046e-01 -1.14942876e-02 1.12755439e-01 -0.10211737 0.24383200 298.25 7.32354175e-02 3.31263117e-02 8.03789706e-02 0.42478687 0.14394704 298.50 6.61392734e-02 2.75728903e-03 6.61967230e-02 0.04166501 0.07605237 298.75 7.88346692e-02 8.05970702e-03 7.92455926e-02 0.10188159 0.11998027 299.00 6.20165234e-02 1.14920191e-02 6.30723051e-02 0.18322739 0.06669602 299.25 8.17791751e-02 2.11710514e-02 8.44751259e-02 0.25331936 0.10872988 299.50 1.20684427e-01 3.35069789e-02 1.25249546e-01 0.27082013 0.15004254 299.75 1.46178529e-01 1.25484370e-02 1.46716139e-01 0.08563330 0.26951432 300.00 1.55549330e-01 1.03029856e-02 1.55890171e-01 0.06613952 0.27738037 300.25 1.50843286e-01 -3.77049343e-02 1.55484272e-01 -0.24494193 0.26469770 300.50 1.44890728e-01 -6.27223640e-02 1.57884191e-01 -0.40853811 0.26134397 300.75 1.43010511e-01 -3.50070375e-02 1.47232805e-01 -0.24006582 0.24638053 301.00 1.20363263e-01 -3.92199678e-02 1.26591947e-01 -0.31499749 0.15337881 301.25 1.50895248e-01 -1.13578168e-02 1.51322093e-01 -0.07512788 0.24706973 301.50 1.65983466e-01 -1.54514963e-02 1.66701109e-01 -0.09282306 0.30316935 301.75 1.72137052e-01 -5.82382578e-02 1.81721928e-01 -0.32623625 0.41095734 302.00 1.60327826e-01 -8.61068908e-02 1.81987386e-01 -0.49286017 0.30286782 302.25 2.18952049e-01 -1.25583136e-01 2.52410626e-01 -0.52075484 0.56122270 302.50 1.79675843e-01 -6.57231307e-02 1.91318944e-01 -0.35066937 0.27104026 302.75 1.45627227e-01 -7.39258640e-02 1.63316633e-01 -0.46973905 0.19560913 303.00 2.00883620e-01 -1.15221765e-01 2.31582132e-01 -0.52076248 0.23405899 303.25 1.62502643e-01 -1.42389280e-01 2.16059751e-01 -0.71952478 0.26670799 303.50 1.83010969e-01 -1.65375582e-01 2.46661910e-01 -0.73482116 0.32369990 303.75 1.44457777e-01 -1.61111127e-01 2.16390491e-01 -0.83984379 0.30017939 304.00 1.76732885e-01 -1.09693807e-01 2.08007798e-01 -0.55548366 0.22920068 304.25 1.71385634e-01 -8.05210982e-02 1.89358609e-01 -0.43921679 0.21733261 304.50 2.42780146e-01 -1.17661372e-01 2.69789544e-01 -0.45128562 0.27316081 304.75 2.10530400e-01 -1.31310160e-01 2.48123775e-01 -0.55767197 0.28342322 305.00 2.60345306e-01 -1.49389548e-01 3.00161483e-01 -0.52094184 0.27515613 305.25 2.62742867e-01 -1.13615734e-01 2.86255741e-01 -0.40814012 0.28004782 305.50 2.25615589e-01 -2.14591144e-01 3.11370765e-01 -0.76035961 0.25448038 305.75 1.48791892e-01 -2.78611253e-01 3.15853221e-01 -1.08028246 0.24091736 306.00 4.26863615e-01 -3.70570019e-01 5.65273990e-01 -0.71492162 0.41006786 306.25 4.13149714e-01 -4.29025030e-01 5.95613266e-01 -0.80424631 0.40322966 306.50 1.95237951e-01 -3.72249294e-01 4.20341997e-01 -1.08775570 0.26051805 306.75 1.11233671e-01 -3.75530510e-01 3.91658133e-01 -1.28282565 0.20078862 307.00 2.87247586e-02 -6.16167939e-01 6.16837127e-01 -1.52421166 0.37619910 307.25 -6.36528861e-02 -5.15977265e-01 5.19888669e-01 -1.69353991 0.33918292 307.50 -6.48578951e-02 -4.65589514e-01 4.70085249e-01 -1.70920835 0.43412355 307.75 -4.41246493e-02 -4.20448082e-01 4.22757110e-01 -1.67536029 0.38813205 308.00 -1.21700275e-01 -4.02387864e-01 4.20389046e-01 -1.86449490 0.41039065 308.25 -1.14374832e-01 -3.43678636e-01 3.62210722e-01 -1.89206309 0.33938492 308.50 -1.97942015e-01 -4.50649672e-01 4.92205413e-01 -1.98466379 0.46165332 308.75 -2.39429204e-01 -4.49916987e-01 5.09658355e-01 -2.05984210 0.48278498 309.00 -2.10728737e-01 -4.80996173e-01 5.25132288e-01 -1.98371779 0.55316974 309.25 -2.37920646e-01 -4.18062593e-01 4.81022417e-01 -2.08818751 0.46533456 309.50 -2.42253139e-01 -4.37856306e-01 5.00404564e-01 -2.07614729 0.40698457 309.75 -1.46877970e-01 -3.70024266e-01 3.98109401e-01 -1.94866325 0.24899311 310.00 -1.64657402e-01 -2.42426076e-01 2.93057098e-01 -2.16743028 0.24505645 310.25 -1.33065036e-01 -2.77459262e-01 3.07717315e-01 -2.01797818 0.26356816 310.50 -2.16657133e-01 -3.03786243e-01 3.73130533e-01 -2.19031951 0.40487407 310.75 -7.98376237e-02 -3.56053035e-01 3.64894245e-01 -1.79137735 0.40773396 311.00 5.34795614e-02 -3.92973116e-01 3.96595428e-01 -1.43553764 0.47994662 311.25 2.16264162e-01 -4.97715906e-01 5.42670536e-01 -1.16089553 0.57059697 311.50 2.92207169e-01 -6.56774068e-01 7.18844354e-01 -1.15218099 0.72637152 311.75 3.19068867e-01 -7.28649526e-01 7.95446462e-01 -1.15805798 0.68331732 312.00 3.35828002e-01 -8.48438567e-01 9.12484766e-01 -1.19389955 0.72416089 312.25 5.43977675e-01 -8.19937095e-01 9.83975889e-01 -0.98503208 0.66959743 312.50 9.03068235e-01 -6.27718236e-01 1.09980108e+00 -0.60742644 0.60397451 312.75 1.02519835e+00 -2.83011661e-01 1.06354466e+00 -0.26934725 0.46111864 313.00 1.26318499e+00 -1.26908653e-01 1.26954406e+00 -0.10013120 0.49993090 313.25 1.09632093e+00 -1.86396232e-02 1.09647938e+00 -0.01700034 0.34663161 313.50 1.07502757e+00 6.32092906e-03 1.07504615e+00 0.00587972 0.44652129 313.75 9.12050995e-01 8.90704260e-02 9.16389960e-01 0.09735077 0.61813425 314.00 7.75687532e-01 1.32909780e-01 7.86991840e-01 0.16969659 0.73605975 314.25 5.65627034e-01 1.47497300e-01 5.84542039e-01 0.25508708 0.67292521 314.50 4.57014444e-01 1.71457303e-01 4.88118642e-01 0.35891816 0.66729408 314.75 3.74096233e-01 2.29833721e-01 4.39057548e-01 0.55091915 0.65076663 315.00 3.30223897e-01 2.57357407e-01 4.18665328e-01 0.66201716 0.68840777 315.25 2.75496258e-01 2.67811561e-01 3.84215070e-01 0.77125483 0.55664944 315.50 2.74595472e-01 2.69933761e-01 3.85054423e-01 0.77683738 0.65656665 315.75 1.75731260e-01 2.38277965e-01 2.96070708e-01 0.93533991 0.54555846 316.00 1.27885816e-01 2.00247866e-01 2.37600484e-01 1.00245025 0.49796658 316.25 6.40259204e-02 2.14598764e-01 2.23946306e-01 1.28085236 0.47000690 316.50 3.76329926e-02 2.21366627e-01 2.24542704e-01 1.40240325 0.48400324 316.75 9.06629962e-03 2.38596811e-01 2.38769002e-01 1.53281619 0.57720062 317.00 1.61548642e-03 2.40888773e-01 2.40894190e-01 1.56409007 0.53362544 317.25 1.03926279e-02 3.06294465e-01 3.06470726e-01 1.53687915 0.64276015 317.50 5.07517282e-03 3.26827165e-01 3.26866568e-01 1.55526896 0.63220490 317.75 4.04075974e-02 3.46525535e-01 3.48873502e-01 1.45471273 0.52868088 318.00 5.25811850e-02 3.58389134e-01 3.62225831e-01 1.42512029 0.59821952 318.25 1.26026849e-01 3.64447144e-01 3.85622208e-01 1.23786553 0.71391389 318.50 1.16767050e-01 3.67043610e-01 3.85169515e-01 1.26279192 0.67355247 318.75 1.32583688e-01 3.68641174e-01 3.91758535e-01 1.22554608 0.60764986 319.00 1.43719707e-01 3.35359710e-01 3.64858177e-01 1.16591936 0.61669971 319.25 3.10212874e-01 2.69650442e-01 4.11027235e-01 0.71556021 0.71053608 319.50 3.00830505e-01 2.36853814e-01 3.82882125e-01 0.66696936 0.65734018 319.75 2.24810779e-01 1.67730654e-01 2.80487894e-01 0.64099852 0.49341444 320.00 2.15144871e-01 1.37754538e-01 2.55467470e-01 0.56951701 0.47244022 320.25 2.15800001e-01 1.91494749e-01 2.88513222e-01 0.72579400 0.58667256 320.50 2.39911196e-01 1.80002536e-01 2.99930483e-01 0.64368552 0.61712198 320.75 3.19168990e-01 1.75157288e-01 3.64072684e-01 0.50191505 0.78042960 321.00 3.67236315e-01 1.20537874e-01 3.86512471e-01 0.31715029 0.72037556 321.25 4.28730446e-01 2.50408972e-02 4.29461106e-01 0.05834081 0.76980970 321.50 3.98678166e-01 -8.93107668e-02 4.08559290e-01 -0.22037880 0.66586588 321.75 3.29649220e-01 -2.54813912e-01 4.16651818e-01 -0.65804997 0.69020109 322.00 2.23318717e-01 -2.65984555e-01 3.47302509e-01 -0.87237529 0.63725544 322.25 1.25574685e-01 -2.33177983e-01 2.64841412e-01 -1.07679741 0.63462390 322.50 7.34445241e-02 -1.86140907e-01 2.00106310e-01 -1.19498481 0.41477767 322.75 2.40207003e-02 -1.28316757e-01 1.30545717e-01 -1.38573968 0.23503714 323.00 -2.41143082e-02 -1.60073156e-01 1.61879323e-01 -1.72031756 0.27565842 323.25 -7.50230686e-02 -1.24559609e-01 1.45408243e-01 -2.11291010 0.28725708 323.50 -7.97271301e-02 -8.17936410e-02 1.14221780e-01 -2.34340110 0.17393415 323.75 -1.03948746e-01 -6.39261848e-02 1.22032368e-01 -2.59023270 0.24631519 324.00 -9.14290344e-02 -1.96687108e-02 9.35207278e-02 -2.92969660 0.11762970 324.25 -7.99907662e-02 4.36644417e-03 8.01098528e-02 3.08705992 0.13606266 324.50 -7.02540628e-02 4.16989433e-02 8.16972167e-02 2.60593304 0.15337474 324.75 -7.09334810e-02 3.95875127e-02 8.12325667e-02 2.63255689 0.18967971 325.00 -5.33519617e-02 4.14463829e-02 6.75591184e-02 2.48112886 0.10461263 325.25 -4.32957657e-02 4.91472381e-02 6.54978957e-02 2.29298066 0.11463031 325.50 -3.05535338e-02 5.80894117e-02 6.56345807e-02 2.05500675 0.10069139 325.75 -1.09730156e-02 1.00105246e-01 1.00704852e-01 1.67997523 0.27253013 326.00 -6.43318353e-03 4.74767954e-02 4.79106663e-02 1.70547768 0.07330444 326.25 -8.22978863e-03 4.61066071e-02 4.68353354e-02 1.74743090 0.08252846 326.50 -1.21959835e-02 2.43837151e-02 2.72636677e-02 2.03457930 0.03662200 326.75 -9.29123108e-04 2.78194406e-02 2.78349519e-02 1.60418226 0.03951267 327.00 9.94447386e-03 4.18580950e-02 4.30231644e-02 1.33754470 0.04825914 327.25 2.34869107e-02 1.67485572e-02 2.88469954e-02 0.61946507 0.02597240 327.50 1.73699196e-02 8.42029655e-03 1.93032511e-02 0.45138398 0.00998721 327.75 7.25809967e-03 2.22594312e-02 2.34128659e-02 1.25559830 0.01395954 328.00 4.79510396e-03 7.74640302e-03 9.11042160e-03 1.01651575 0.00174951 328.25 2.06266952e-02 4.38136700e-03 2.10868901e-02 0.20930163 0.00989649 328.50 -3.84210185e-02 4.00494595e-02 5.54989537e-02 2.33544519 0.05819973 328.75 -3.04223259e-02 5.23793608e-02 6.05732231e-02 2.09698415 0.06751212 329.00 -2.55243870e-02 3.98746015e-02 4.73442518e-02 2.14019210 0.04277120 329.25 -9.84370050e-03 2.92290571e-02 3.08421176e-02 1.89564378 0.01685405 329.50 4.41976544e-02 -1.31884212e-03 4.42173270e-02 -0.02983079 0.04476421 329.75 2.19102037e-02 2.36247263e-03 2.20372027e-02 0.10741025 0.01106607 330.00 -5.49940261e-02 2.76455289e-02 6.15517520e-02 2.67578691 0.08475027 330.25 -2.86829307e-02 3.32906491e-02 4.39428928e-02 2.28198132 0.04167819 330.50 -1.49913823e-03 5.75511343e-02 5.75706564e-02 1.59683924 0.08690094 330.75 -7.44138364e-04 7.34003755e-02 7.34041475e-02 1.58093405 0.10579559 331.00 4.57699367e-02 6.75502757e-02 8.15961203e-02 0.97528425 0.15097451 331.25 8.55166606e-02 5.26476841e-02 1.00423493e-01 0.55184195 0.18140976 331.50 9.27219394e-02 -6.09906598e-03 9.29223151e-02 -0.06568340 0.18476071 331.75 1.05401141e-01 -3.55651295e-02 1.11239737e-01 -0.32542980 0.21388084 332.00 9.09808152e-02 -4.04583602e-02 9.95710181e-02 -0.41843029 0.23860377 332.25 8.42088251e-02 -8.80316406e-02 1.21822395e-01 -0.80758916 0.21462853 332.50 5.25014063e-02 -1.63201284e-01 1.71438201e-01 -1.25955453 0.43197649 332.75 -1.34235878e-02 -1.57587990e-01 1.58158678e-01 -1.65577274 0.38147562 333.00 -8.85790142e-02 -1.42799287e-01 1.68041299e-01 -2.12601184 0.51855247 333.25 -1.31725773e-01 -1.02433772e-01 1.66866285e-01 -2.48064224 0.48626693 333.50 -1.55614323e-01 -6.12668218e-02 1.67240668e-01 -2.76652094 0.66174709 333.75 -1.33962724e-01 -5.06781322e-02 1.43228086e-01 -2.77993176 0.46647661 334.00 -9.60524794e-02 -4.35716896e-02 1.05473082e-01 -2.71572927 0.35700223 334.25 -7.62826759e-02 -5.28149609e-02 9.27818233e-02 -2.53601363 0.26475225 334.50 -5.82735310e-02 -6.91625661e-02 9.04392888e-02 -2.27095452 0.32620719 334.75 -7.49320204e-02 -1.11187440e-01 1.34080030e-01 -2.16380726 0.36081433 335.00 -1.14896931e-01 -1.30520795e-01 1.73887845e-01 -2.29261796 0.53314493 335.25 -1.37420736e-01 -8.28902573e-02 1.60484433e-01 -2.59883383 0.41152142 335.50 -1.37223813e-01 -6.92786032e-02 1.53720199e-01 -2.67406583 0.46067285 335.75 -1.48362744e-01 -9.26804809e-02 1.74931917e-01 -2.58321746 0.51029129 336.00 -1.75472034e-01 -8.94673644e-02 1.96964068e-01 -2.67008280 0.60901633 336.25 -1.69256083e-01 -8.01300772e-02 1.87265722e-01 -2.69943008 0.61748104 336.50 -1.89339895e-01 -8.92136575e-02 2.09305214e-01 -2.70126361 0.72328242 336.75 -1.99990220e-01 -5.25782993e-02 2.06786280e-01 -2.88450607 0.69045403 337.00 -2.22186617e-01 -3.87247087e-02 2.25536019e-01 -2.96903683 0.76785074 337.25 -2.49825940e-01 -2.00191664e-02 2.50626749e-01 -3.06163105 0.79597633 337.50 -2.47414090e-01 -1.48842912e-02 2.47861401e-01 -3.08150564 0.82545231 337.75 -2.48180782e-01 -4.99853031e-03 2.48231114e-01 -3.12145469 0.74591000 338.00 -2.48792680e-01 5.56352262e-03 2.48854878e-01 3.11923430 0.75588278 338.25 -2.68239175e-01 2.92789348e-02 2.69832376e-01 3.03287073 0.79941652 338.50 -2.65250126e-01 2.79723268e-02 2.66720979e-01 3.03652458 0.77687688 338.75 -2.54873355e-01 6.78550707e-02 2.63751280e-01 2.88139748 0.74188618 339.00 -2.52443319e-01 6.43741483e-02 2.60521900e-01 2.89190957 0.66508508 339.25 -2.82847061e-01 9.88417190e-02 2.99620001e-01 2.80540533 0.74364669 339.50 -2.66900532e-01 1.04208473e-01 2.86522773e-01 2.76935528 0.72499586 339.75 -2.45822964e-01 1.50439763e-01 2.88203144e-01 2.59240783 0.67802738 340.00 -2.38875519e-01 1.49707345e-01 2.81910984e-01 2.58175961 0.61249889 340.25 -2.30702384e-01 1.64116015e-01 2.83121275e-01 2.52327288 0.60898683 340.50 -2.25043686e-01 2.01734351e-01 3.02227413e-01 2.41075728 0.60104192 340.75 -2.60771133e-01 2.61481721e-01 3.69288877e-01 2.35483387 0.64289979 341.00 -2.30156478e-01 2.93494016e-01 3.72975525e-01 2.23582537 0.55531972 341.25 -1.65700833e-01 3.48787650e-01 3.86147111e-01 2.01430712 0.50841962 341.50 -9.82680649e-02 2.86587586e-01 3.02967089e-01 1.90112323 0.27472410 341.75 4.60439804e-02 2.04321915e-01 2.09445681e-01 1.34914860 0.19768179 342.00 1.79590233e-02 1.85144153e-01 1.86013128e-01 1.47409863 0.16809374 342.25 9.45027885e-02 1.17532961e-01 1.50813706e-01 0.89358862 0.15072356 342.50 7.29263853e-02 5.37876125e-02 9.06165820e-02 0.63549210 0.03822175 342.75 7.80459274e-02 -9.85556255e-03 7.86657415e-02 -0.12561413 0.04855690 343.00 2.07695428e-02 1.67862130e-03 2.08372666e-02 0.08064600 0.00349484 343.25 -2.72598892e-02 -9.10290491e-03 2.87395970e-02 -2.81930486 0.01025077 343.50 2.33970252e-02 -5.99401304e-02 6.43446969e-02 -1.19864525 0.04354678 343.75 4.14448229e-02 -9.09372847e-02 9.99362952e-02 -1.14316958 0.14714918 344.00 3.03417919e-02 -1.12236567e-01 1.16265521e-01 -1.30676963 0.15970226 344.25 3.29681205e-02 -1.52657132e-01 1.56176493e-01 -1.35810097 0.30897832 344.50 1.85096253e-02 -2.44712327e-01 2.45411347e-01 -1.49530178 0.33444341 344.75 2.30215049e-03 -4.06151202e-01 4.06157726e-01 -1.56512818 0.56574173 345.00 -2.55265433e-01 -4.70958361e-01 5.35688546e-01 -2.06748661 0.55267524 345.25 -4.31015025e-01 -4.15155213e-01 5.98437802e-01 -2.37493535 0.74139996 345.50 -4.81792347e-01 -3.89300049e-01 6.19417786e-01 -2.46197780 0.75178291 345.75 -5.45793349e-01 -3.27702292e-01 6.36615404e-01 -2.60086836 0.81850133 346.00 -5.66585574e-01 -2.92877565e-01 6.37805990e-01 -2.66450343 0.85614441 346.25 -5.74773415e-01 -3.00624838e-01 6.48644565e-01 -2.65968974 0.90204140 346.50 -6.41063326e-01 -2.66870069e-01 6.94393132e-01 -2.74712011 0.88635584 346.75 -6.92948034e-01 -2.45634406e-01 7.35196055e-01 -2.80093466 0.89397971 347.00 -7.64645890e-01 -2.70602548e-01 8.11115945e-01 -2.80145423 0.86482755 347.25 -8.30687847e-01 -3.29368031e-01 8.93602596e-01 -2.76410684 0.89686689 347.50 -9.47964700e-01 -2.81988392e-01 9.89016949e-01 -2.85246116 0.88754118 347.75 -1.09419300e+00 -2.32129189e-01 1.11854472e+00 -2.93254554 0.88918491 348.00 -1.25315475e+00 -1.11043778e-01 1.25806500e+00 -3.05321211 0.83247569 348.25 -1.37735175e+00 -1.75975234e-02 1.37746416e+00 -3.12881700 0.85642920 348.50 -1.67490654e+00 2.11554287e-01 1.68821418e+00 3.01594988 0.89324619 348.75 -1.74364948e+00 3.72755600e-01 1.78304802e+00 2.93098386 0.92601495 349.00 -1.80785207e+00 6.42055711e-01 1.91847977e+00 2.80033870 0.93336474 349.25 -1.83139569e+00 7.63846845e-01 1.98430648e+00 2.74644552 0.92478818 349.50 -1.79440228e+00 1.28175074e+00 2.20516768e+00 2.52133031 0.93563801 349.75 -1.77200562e+00 1.43286261e+00 2.27883725e+00 2.46162332 0.94421709 350.00 -1.58811767e+00 1.78468297e+00 2.38897698e+00 2.29798079 0.93848592 350.25 -1.49831784e+00 1.93662704e+00 2.44856706e+00 2.22927739 0.94395777 350.50 -1.20051279e+00 2.06394180e+00 2.38769486e+00 2.09762152 0.95949658 350.75 -1.04719207e+00 2.20157537e+00 2.43793874e+00 2.01477959 0.95221008 351.00 -6.97925689e-01 2.38346035e+00 2.48354253e+00 1.85565334 0.96017235 351.25 -5.12769253e-01 2.43129350e+00 2.48477773e+00 1.77865407 0.96241642 351.50 -1.62059283e-01 2.41042348e+00 2.41586518e+00 1.63792800 0.97038128 351.75 2.35140193e-02 2.37883298e+00 2.37894920e+00 1.56091196 0.96538292 352.00 1.76659506e-01 2.34698764e+00 2.35362689e+00 1.49566725 0.95395941 352.25 3.95672643e-01 2.06775699e+00 2.10527333e+00 1.38172831 0.92958993 352.50 4.28754590e-01 1.90875699e+00 1.95631892e+00 1.34983882 0.97183358 352.75 3.61651931e-01 1.81680944e+00 1.85245477e+00 1.37430592 0.95700124 353.00 2.41402313e-01 1.66291450e+00 1.68034511e+00 1.42663517 0.94760337 353.25 1.23509427e-01 1.70820244e+00 1.71266171e+00 1.49861819 0.90996596 353.50 -8.47903303e-02 1.85284400e+00 1.85478308e+00 1.61652668 0.92631166 353.75 -3.03598606e-01 2.15582519e+00 2.17709769e+00 1.71070337 0.87843548 354.00 -7.03122014e-01 2.68812299e+00 2.77855822e+00 1.82663082 0.93202669 354.25 -6.53170626e-01 3.27681681e+00 3.34128123e+00 1.76754837 0.90570337 354.50 -3.41294487e-01 4.27560234e+00 4.28920241e+00 1.65045115 0.89137887 354.75 5.94408942e-01 5.48348135e+00 5.51560420e+00 1.46281802 0.87589823 355.00 2.19819729e+00 6.58812768e+00 6.94517801e+00 1.24875144 0.90868851 355.25 4.67980883e+00 6.99230901e+00 8.41385738e+00 0.98098704 0.86400084 355.50 7.76111576e+00 6.08670917e+00 9.86321177e+00 0.66506755 0.86508476 355.75 9.90786414e+00 2.49866904e+00 1.02180780e+01 0.24703923 0.77276997 356.00 1.12231135e+01 -8.47598968e-01 1.12550745e+01 -0.07537953 0.72123667 356.25 4.87086054e+00 -6.12447367e+00 7.82524505e+00 -0.89892115 0.55549666 356.50 1.41406734e+00 -6.63767462e+00 6.78662735e+00 -1.36089762 0.66179932 356.75 -1.57458806e+00 -3.51102594e+00 3.84793850e+00 -1.99237676 0.57691176 357.00 -1.98959416e+00 -3.04243345e+00 3.63522850e+00 -2.14994214 0.79628218 357.25 -1.71983425e+00 -1.77942178e+00 2.47470639e+00 -2.33916751 0.77043731 357.50 -1.51607141e+00 -1.11432527e+00 1.88154015e+00 -2.50775539 0.77051003 357.75 -1.21409823e+00 -7.38274066e-01 1.42094444e+00 -2.59525001 0.66424299 358.00 -9.70695821e-01 -3.54446672e-01 1.03338416e+00 -2.79148808 0.42494254 358.25 -3.42066411e-01 2.42861547e-01 4.19513004e-01 2.52419766 0.19312390 358.50 -1.60759448e-01 2.53787220e-01 3.00418963e-01 2.13544317 0.22601007 358.75 7.65810430e-02 2.01768371e-01 2.15812724e-01 1.20804321 0.25852076 359.00 1.36738852e-01 1.57385377e-01 2.08489018e-01 0.85547982 0.33201781 359.25 2.36530318e-01 7.29399594e-02 2.47521371e-01 0.29912216 0.50817663 359.50 2.57566480e-01 3.52126427e-02 2.59962347e-01 0.13587052 0.58126174 359.75 2.55646113e-01 -3.39977729e-02 2.57896847e-01 -0.13221186 0.71726710 360.00 2.44669892e-01 -4.27487885e-02 2.48376357e-01 -0.17297423 0.72324109 360.25 2.22507594e-01 -3.43328706e-02 2.25140790e-01 -0.15309243 0.74233210 360.50 2.19381114e-01 -4.10451993e-02 2.23187772e-01 -0.18495707 0.75380923 360.75 2.05202021e-01 -2.48555646e-02 2.06701884e-01 -0.12054006 0.72681264 361.00 1.96904933e-01 -2.38818313e-02 1.98347912e-01 -0.12069658 0.59536253 361.25 1.68652712e-01 -1.91977793e-02 1.69741839e-01 -0.11334239 0.44163208 361.50 1.09098162e-01 -1.14143906e-03 1.09104133e-01 -0.01046211 0.17383136 361.75 4.53481749e-02 9.58163968e-02 1.06005844e-01 1.12875067 0.28359074 362.00 4.75205574e-02 1.04163875e-01 1.14491556e-01 1.14279053 0.31828830 362.25 -3.27810908e-03 1.26013265e-01 1.26055896e-01 1.59680446 0.44008862 362.50 -1.31386671e-02 1.60589403e-01 1.61125978e-01 1.65242979 0.53981626 362.75 -7.89770124e-03 2.41072348e-01 2.41201680e-01 1.60354532 0.73712259 363.00 1.08663750e-03 3.19818526e-01 3.19820373e-01 1.56739867 0.77941121 363.25 3.76561196e-02 3.91161570e-01 3.92969919e-01 1.47482464 0.79705341 363.50 1.09316982e-01 4.07039641e-01 4.21463488e-01 1.30842160 0.82539195 363.75 1.56881754e-01 4.11224027e-01 4.40133031e-01 1.20633969 0.89278799 364.00 1.44834962e-01 4.13453952e-01 4.38088275e-01 1.23384987 0.86857802 364.25 1.40321511e-01 4.18232977e-01 4.41145044e-01 1.24708770 0.90693807 364.50 9.66408253e-02 4.35991005e-01 4.46573180e-01 1.35266527 0.86460555 364.75 3.34032479e-02 5.13137433e-01 5.14223494e-01 1.50579194 0.84317540 365.00 4.92114055e-02 6.61058099e-01 6.62887301e-01 1.49649000 0.80277406 365.25 2.60897539e-01 8.30097164e-01 8.70131500e-01 1.26627463 0.77808123 365.50 5.44210920e-01 6.20285531e-01 8.25178566e-01 0.85063380 0.78834617 365.75 5.71954994e-01 4.61924919e-01 7.35191911e-01 0.67937282 0.89599314 366.00 4.56659385e-01 4.40532876e-01 6.34513206e-01 0.76742568 0.90231975 366.25 4.32192085e-01 4.60530432e-01 6.31568110e-01 0.81713124 0.93690331 366.50 3.89769860e-01 5.04903509e-01 6.37846452e-01 0.91338267 0.92495003 366.75 3.83917072e-01 5.28069348e-01 6.52877901e-01 0.94216524 0.94257424 367.00 3.74868194e-01 5.60907269e-01 6.74642962e-01 0.98164672 0.93458684 367.25 3.33109660e-01 5.88735436e-01 6.76440285e-01 1.05589952 0.94879636 367.50 3.24332818e-01 6.36728017e-01 7.14572841e-01 1.09967752 0.91838924 367.75 3.24271483e-01 7.27337035e-01 7.96348641e-01 1.15141236 0.90797521 368.00 3.50657750e-01 9.40188744e-01 1.00345191e+00 1.21381072 0.87940984 368.25 4.21549237e-01 1.06116629e+00 1.14183083e+00 1.19266213 0.88946130 368.50 1.76314766e-01 1.14383672e+00 1.15734581e+00 1.41785674 0.75815472 368.75 -6.08869966e-02 1.12728183e+00 1.12892495e+00 1.62475612 0.53392279 369.00 1.18330375e-01 1.69604521e-03 1.18342529e-01 0.01433215 0.00246968 369.25 8.07351731e-01 -9.77503215e-01 1.26780494e+00 -0.88044165 0.36317302 369.50 6.51562694e-01 -7.63045989e-01 1.00338085e+00 -0.86404419 0.75241918 369.75 5.93151056e-01 -5.30181226e-01 7.95562887e-01 -0.72940049 0.75782897 370.00 6.84119707e-01 -2.54479733e-01 7.29917603e-01 -0.35612151 0.93850173 370.25 6.47441216e-01 -1.92689019e-01 6.75506614e-01 -0.28926842 0.94641332 370.50 6.43636403e-01 -2.44843748e-02 6.44101936e-01 -0.03802236 0.95674856 370.75 6.78906917e-01 3.29786835e-02 6.79707434e-01 0.04853800 0.96641479 371.00 7.19846685e-01 9.70567347e-02 7.26360282e-01 0.13402150 0.98129112 371.25 7.48360794e-01 1.11891699e-01 7.56679344e-01 0.14841628 0.98070828 371.50 7.95834989e-01 1.40547684e-01 8.08150345e-01 0.17480163 0.98478859 371.75 8.28495769e-01 1.55320579e-01 8.42929250e-01 0.18532186 0.98516604 372.00 8.93958814e-01 1.54239881e-01 9.07167186e-01 0.17085367 0.99058616 372.25 9.17626117e-01 1.32017307e-01 9.27074031e-01 0.14288785 0.99237089 372.50 9.51875234e-01 9.64376009e-02 9.56747966e-01 0.10096876 0.99495529 372.75 9.72243740e-01 6.94805229e-02 9.74723260e-01 0.07134281 0.99202507 373.00 9.91439177e-01 3.59201347e-03 9.91445684e-01 0.00362301 0.99255596 373.25 9.80877984e-01 -3.75726587e-02 9.81597333e-01 -0.03828641 0.99075400 373.50 9.45529564e-01 -7.34517736e-02 9.48378258e-01 -0.07752751 0.99131692 373.75 9.29329642e-01 -9.46526162e-02 9.34137410e-01 -0.10150042 0.99244987 374.00 9.17997495e-01 -1.09084666e-01 9.24455983e-01 -0.11827433 0.99566415 374.25 9.17285009e-01 -1.21168798e-01 9.25253298e-01 -0.13133467 0.99429864 374.50 9.16551471e-01 -1.33261697e-01 9.26188576e-01 -0.14438294 0.99446906 374.75 9.01591577e-01 -1.69550549e-01 9.17395640e-01 -0.18588592 0.98926853 375.00 8.86046529e-01 -2.21842008e-01 9.13396041e-01 -0.24532956 0.98885242 375.25 8.38259010e-01 -2.43451809e-01 8.72895728e-01 -0.28264989 0.98256963 375.50 7.90349969e-01 -2.55013425e-01 8.30472709e-01 -0.31211297 0.98131800 375.75 7.40931845e-01 -2.44775398e-01 7.80317240e-01 -0.31907357 0.97374902 376.00 6.89645155e-01 -2.41759618e-01 7.30792825e-01 -0.33717054 0.98155601 376.25 6.26489185e-01 -2.05395070e-01 6.59299503e-01 -0.31680831 0.97611639 376.50 5.95099746e-01 -1.70523690e-01 6.19049301e-01 -0.27906880 0.98514201 376.75 6.10522589e-01 -1.30250912e-01 6.24262070e-01 -0.21019213 0.98653455 377.00 6.35831249e-01 -1.16715542e-01 6.46454866e-01 -0.18154265 0.99103499 377.25 6.57787544e-01 -1.43186568e-01 6.73191538e-01 -0.21433543 0.98606110 377.50 6.63242969e-01 -1.79087556e-01 6.86996062e-01 -0.26372863 0.98870759 377.75 6.03189890e-01 -1.99079557e-01 6.35193446e-01 -0.31878777 0.97803226 378.00 5.48346735e-01 -1.96724057e-01 5.82567161e-01 -0.34445609 0.97335204 378.25 4.83209275e-01 -1.26549887e-01 4.99505833e-01 -0.25614185 0.94962198 378.50 4.48305783e-01 -6.63894450e-02 4.53194918e-01 -0.14702111 0.95363460 378.75 4.37363424e-01 2.12277967e-02 4.37878275e-01 0.04849777 0.93824093 379.00 4.36268434e-01 7.53345496e-02 4.42725017e-01 0.17099309 0.93778763 379.25 4.98967833e-01 1.48208425e-01 5.20513819e-01 0.28872982 0.95612525 379.50 5.25136957e-01 1.69593132e-01 5.51842961e-01 0.31237689 0.96606592 379.75 5.67650462e-01 2.22365290e-01 6.09650202e-01 0.37335615 0.96184504 380.00 6.10357083e-01 2.30531810e-01 6.52442092e-01 0.36113560 0.96814919 380.25 6.38972526e-01 2.27155000e-01 6.78148423e-01 0.34156654 0.97671785 380.50 6.52314969e-01 2.39334519e-01 6.94835110e-01 0.35165067 0.97010337 380.75 7.03915618e-01 3.14409113e-01 7.70941170e-01 0.42007074 0.96466851 381.00 7.38988155e-01 3.69567425e-01 8.26246680e-01 0.46372701 0.96419915 381.25 7.77859856e-01 4.88310410e-01 9.18429645e-01 0.56058259 0.96843957 381.50 8.51788827e-01 5.04722985e-01 9.90095701e-01 0.53491965 0.97116763 381.75 1.00073764e+00 5.64379781e-01 1.14891269e+00 0.51350071 0.97063922 382.00 1.09707256e+00 5.98009342e-01 1.24947324e+00 0.49906998 0.96951234 382.25 1.34650171e+00 5.75401587e-01 1.46429295e+00 0.40384316 0.97209496 382.50 1.49136826e+00 5.01314621e-01 1.57337078e+00 0.32427810 0.96178761 382.75 1.65771414e+00 2.61239705e-01 1.67817233e+00 0.15630485 0.97283023 383.00 1.72462999e+00 9.43482787e-02 1.72720879e+00 0.05465191 0.96727303 383.25 1.79717669e+00 -1.97783836e-01 1.80802724e+00 -0.10961143 0.97400231 383.50 1.66177903e+00 -4.40522244e-01 1.71917695e+00 -0.25913052 0.95963517 383.75 1.48023637e+00 -6.02321067e-01 1.59808961e+00 -0.38644793 0.98193752 384.00 1.32148268e+00 -6.33981198e-01 1.46569050e+00 -0.44731670 0.97300186 384.25 1.11330499e+00 -6.14171804e-01 1.27147749e+00 -0.50412090 0.98152335 384.50 9.90938248e-01 -5.56771610e-01 1.13664121e+00 -0.51190549 0.97429731 384.75 8.94927153e-01 -4.92554356e-01 1.02152063e+00 -0.50313864 0.98625427 385.00 8.87790559e-01 -4.37409116e-01 9.89696323e-01 -0.45778578 0.98411472 385.25 8.74257772e-01 -3.70517080e-01 9.49531231e-01 -0.40086023 0.98619045 385.50 8.59067353e-01 -3.38044839e-01 9.23185263e-01 -0.37489225 0.98264324 385.75 8.56856844e-01 -3.05175201e-01 9.09579878e-01 -0.34214896 0.98435556 386.00 8.39862228e-01 -2.49914015e-01 8.76256570e-01 -0.28922180 0.98045874 386.25 8.15587825e-01 -2.13444234e-01 8.43055124e-01 -0.25596538 0.98634168 386.50 8.36287645e-01 -1.30369984e-01 8.46388421e-01 -0.15464659 0.97641486 386.75 8.67140930e-01 -2.38828309e-02 8.67469758e-01 -0.02753508 0.97686649 387.00 1.01521097e+00 -1.92922394e-03 1.01521281e+00 -0.00190032 0.97557761 387.25 1.09429566e+00 -1.21491387e-02 1.09436310e+00 -0.01110179 0.98965999 387.50 1.14117588e+00 -4.01202954e-02 1.14188092e+00 -0.03514250 0.98927692 387.75 1.17194762e+00 -5.45820379e-02 1.17321798e+00 -0.04654016 0.99150211 388.00 1.22041820e+00 -6.65646525e-02 1.22223215e+00 -0.05448850 0.98685198 388.25 1.27283792e+00 -6.54060074e-02 1.27451729e+00 -0.05134081 0.98462002 388.50 1.35287661e+00 -9.37206197e-02 1.35611898e+00 -0.06916457 0.98474405 388.75 1.40238319e+00 -1.08692008e-01 1.40658898e+00 -0.07735058 0.98585876 389.00 1.55701026e+00 -1.60612556e-01 1.56527229e+00 -0.10279090 0.97418268 389.25 1.66810980e+00 -2.46544557e-01 1.68623086e+00 -0.14673645 0.97905779 389.50 1.68915874e+00 -4.77325747e-01 1.75530542e+00 -0.27540132 0.96844864 389.75 1.71429437e+00 -6.47273088e-01 1.83242125e+00 -0.36102547 0.97475362 390.00 1.61240960e+00 -8.94992653e-01 1.84414657e+00 -0.50672381 0.96913745 390.25 1.49700568e+00 -9.53455277e-01 1.77485294e+00 -0.56711676 0.96944001 390.50 1.37535748e+00 -1.00151095e+00 1.70136192e+00 -0.62939093 0.97495374 390.75 1.34019972e+00 -1.00311350e+00 1.67402867e+00 -0.64252799 0.96848994 391.00 1.18387862e+00 -1.05049949e+00 1.58275638e+00 -0.72577484 0.97020621 391.25 1.11270226e+00 -1.06271080e+00 1.53865544e+00 -0.76242199 0.97273225 391.50 9.73670988e-01 -9.49380348e-01 1.35991111e+00 -0.77276753 0.95934485 391.75 9.33056437e-01 -8.93346299e-01 1.29176698e+00 -0.76365932 0.96019290 392.00 9.92901713e-01 -8.98445497e-01 1.33905120e+00 -0.73549839 0.96173036 392.25 1.07326727e+00 -8.70380437e-01 1.38183383e+00 -0.68139026 0.95287242 392.50 1.18769114e+00 -8.86728231e-01 1.48219338e+00 -0.64132049 0.94171342 392.75 1.15000003e+00 -1.01235599e+00 1.53211120e+00 -0.72182927 0.92115714 393.00 9.67636688e-01 -1.29509999e+00 1.61666470e+00 -0.92912036 0.91307279 393.25 8.38554980e-01 -1.38915611e+00 1.62263032e+00 -1.02770213 0.90669129 393.50 5.54039784e-01 -1.41209913e+00 1.51689948e+00 -1.19690047 0.90690129 393.75 4.09570745e-01 -1.24624671e+00 1.31182280e+00 -1.25327264 0.86434200 394.00 1.62324813e-01 -9.55743008e-01 9.69429751e-01 -1.40256023 0.80669148 394.25 1.18511159e-01 -6.99466525e-01 7.09435208e-01 -1.40295945 0.67826778 394.50 1.33814702e-01 -5.02866532e-01 5.20366335e-01 -1.31071949 0.49817826 394.75 4.07897000e-01 -3.91009414e-01 5.65038339e-01 -0.76426293 0.47012495 395.00 6.32767252e-01 -3.47891517e-01 7.22096186e-01 -0.50268489 0.68519546 395.25 7.43564571e-01 -4.48638583e-01 8.68426652e-01 -0.54288787 0.75592082 395.50 7.86802254e-01 -6.62568403e-01 1.02861785e+00 -0.69989144 0.80631503 395.75 6.02132232e-01 -9.13366678e-01 1.09398442e+00 -0.98794955 0.83979563 396.00 3.68305899e-01 -8.67060125e-01 9.42041664e-01 -1.16911585 0.83911771 396.25 2.97807182e-01 -6.67584911e-01 7.30998448e-01 -1.15119343 0.83660798 396.50 2.97028922e-01 -5.12943785e-01 5.92737300e-01 -1.04591081 0.86074600 396.75 3.07439694e-01 -4.00622976e-01 5.04993004e-01 -0.91624936 0.81026222 397.00 3.57151874e-01 -3.03564307e-01 4.68730999e-01 -0.70447003 0.79758799 397.25 5.09131017e-01 -2.01388256e-01 5.47514039e-01 -0.37666681 0.79104997 397.50 6.75225574e-01 -1.72777401e-01 6.96980349e-01 -0.25050602 0.86120521 397.75 7.87565344e-01 -3.15636032e-01 8.48460533e-01 -0.38117379 0.90275922 398.00 8.11936291e-01 -4.40634328e-01 9.23796055e-01 -0.49721801 0.93563193 398.25 6.93273425e-01 -5.43858056e-01 8.81141094e-01 -0.66520466 0.95641714 398.50 6.53775538e-01 -5.63938096e-01 8.63393671e-01 -0.71175607 0.96655177 398.75 6.06132342e-01 -4.73060313e-01 7.68883916e-01 -0.66271045 0.95203878 399.00 5.94207569e-01 -4.21240680e-01 7.28372394e-01 -0.61668194 0.95930219 399.25 5.97592441e-01 -3.96781203e-01 7.17322835e-01 -0.58613074 0.96711170 399.50 6.08213977e-01 -3.74757370e-01 7.14399977e-01 -0.55221748 0.97607277 399.75 6.17900043e-01 -3.31639254e-01 7.01273882e-01 -0.49259022 0.95921333 400.00 6.17306113e-01 -3.17161989e-01 6.94016256e-01 -0.47461388 0.96271000 400.25 5.93147593e-01 -2.79882694e-01 6.55864612e-01 -0.44088336 0.95827860 400.50 5.68002820e-01 -2.68164610e-01 6.28123763e-01 -0.44109462 0.94384935 400.75 4.58369166e-01 -1.68096383e-01 4.88219916e-01 -0.35149804 0.90102947 401.00 4.28816993e-01 -9.27369749e-02 4.38730168e-01 -0.21298243 0.84554289 401.25 4.05761370e-01 1.42760225e-01 4.30142733e-01 0.33830681 0.81282738 401.50 4.49734224e-01 2.96210050e-01 5.38517656e-01 0.58242058 0.81644711 401.75 5.88414404e-01 5.71094661e-01 8.19988185e-01 0.77046214 0.88195335 402.00 6.88891296e-01 7.23763402e-01 9.99202022e-01 0.81007866 0.88566705 402.25 9.37585403e-01 1.05040934e+00 1.40798656e+00 0.84208998 0.90990048 402.50 1.15015065e+00 1.23429182e+00 1.68710486e+00 0.82067109 0.89978206 402.75 1.91578768e+00 1.46605607e+00 2.41237701e+00 0.65318973 0.86341478 403.00 2.37477595e+00 1.54899018e+00 2.83530093e+00 0.57796789 0.82811038 403.25 3.68558620e+00 8.40681318e-01 3.78025009e+00 0.22426287 0.68776974 403.50 3.34960731e+00 -9.65883279e-02 3.35099962e+00 -0.02882773 0.40999486 403.75 2.59720067e+00 -3.31101610e+00 4.20812059e+00 -0.90563282 0.50484298 404.00 9.06576816e-01 -3.35165200e+00 3.47209629e+00 -1.30663105 0.54428632 404.25 -3.37191146e-01 -3.18300063e+00 3.20081097e+00 -1.67633769 0.75073602 404.50 -6.17339143e-01 -2.38139336e+00 2.46011015e+00 -1.82444715 0.71901645 404.75 -7.15779111e-01 -1.50237907e+00 1.66417626e+00 -2.01541112 0.73107141 405.00 -4.91716605e-01 -9.60517449e-01 1.07906394e+00 -2.04394142 0.62421501 405.25 -2.40719854e-01 -7.02944183e-01 7.43018555e-01 -1.90072501 0.68550293 405.50 -2.02403842e-02 -7.16847337e-01 7.17133026e-01 -1.59902411 0.75463201 405.75 1.91258056e-01 -7.35650466e-01 7.60106080e-01 -1.31644236 0.83206549 406.00 2.44897220e-01 -8.73641929e-01 9.07317402e-01 -1.29749313 0.84290089 406.25 2.12566081e-01 -9.75499193e-01 9.98390211e-01 -1.35624525 0.88999131 406.50 8.55718741e-02 -8.88246288e-01 8.92358680e-01 -1.47475471 0.89696399 406.75 4.71344892e-03 -8.25199335e-01 8.25212797e-01 -1.56508450 0.92017354 407.00 -7.91369552e-02 -7.39989722e-01 7.44209276e-01 -1.67733472 0.85944729 407.25 -1.14150163e-01 -6.51101005e-01 6.61031602e-01 -1.74435118 0.86830575 407.50 -8.56801586e-02 -5.34548183e-01 5.41371268e-01 -1.72972965 0.78882302 407.75 -7.11199557e-02 -4.67227710e-01 4.72609544e-01 -1.72185369 0.78379923 408.00 -7.05303391e-02 -3.93219974e-01 3.99495277e-01 -1.74827521 0.68836407 408.25 -3.13825611e-02 -3.23667653e-01 3.25185508e-01 -1.66745340 0.61238266 408.50 -4.31964373e-04 -2.71673103e-01 2.71673446e-01 -1.57238634 0.49652584 408.75 -3.27903825e-02 -2.59831510e-01 2.61892387e-01 -1.69633134 0.45822388 409.00 -2.13145662e-02 -2.87397799e-01 2.88187101e-01 -1.64482478 0.37837593 409.25 -5.95396890e-02 -2.90379021e-01 2.96420226e-01 -1.77303455 0.43054597 409.50 -1.95568529e-01 -2.10053286e-01 2.87000754e-01 -2.32049965 0.49708048 409.75 -2.61419204e-01 -1.77479543e-01 3.15973082e-01 -2.54516321 0.58281368 410.00 -2.65044539e-01 -1.42387797e-01 3.00870226e-01 -2.64861259 0.45482006 410.25 -2.88350870e-01 -1.09949633e-01 3.08601922e-01 -2.77730579 0.50561844 410.50 -3.90478187e-01 -6.75085259e-02 3.96270887e-01 -2.97039812 0.60114875 410.75 -4.42527896e-01 -7.00212707e-03 4.42583290e-01 -3.12577096 0.62401008 411.00 -5.39982746e-01 1.74097681e-01 5.67354711e-01 2.82970201 0.70684269 411.25 -6.06383529e-01 2.41716469e-01 6.52784678e-01 2.76227669 0.76966437 411.50 -6.99043590e-01 3.42434987e-01 7.78410984e-01 2.68608818 0.80845777 411.75 -6.92198424e-01 3.85442074e-01 7.92277887e-01 2.63351505 0.77581421 412.00 -8.53342959e-01 5.29486744e-01 1.00426611e+00 2.58624647 0.85596642 412.25 -9.02702850e-01 5.73943684e-01 1.06971201e+00 2.57526060 0.87415525 412.50 -9.31257380e-01 6.06900909e-01 1.11156152e+00 2.56402292 0.80607785 412.75 -1.00214188e+00 7.41901612e-01 1.24687864e+00 2.50431820 0.81724689 413.00 -1.06593526e+00 1.00680740e+00 1.46624661e+00 2.38471314 0.86954695 413.25 -9.85141580e-01 1.16272108e+00 1.52395021e+00 2.27370480 0.82929862 413.50 -7.48690109e-01 1.18071162e+00 1.39807611e+00 2.13591324 0.79291530 413.75 -5.36742164e-01 1.17801518e+00 1.29453154e+00 1.99832447 0.74326801 414.00 -4.39230581e-01 9.66234781e-01 1.06138266e+00 1.99745208 0.73900788 414.25 -3.83614388e-01 7.10089248e-01 8.07085335e-01 2.06611078 0.55749359 414.50 -3.66339141e-01 2.54766707e-01 4.46217930e-01 2.53393399 0.26396778 414.75 -3.31424909e-01 4.78734393e-04 3.31425255e-01 3.14014818 0.09886345 415.00 -5.92283443e-01 -4.74960743e-01 7.59201807e-01 -2.46568536 0.34465691 415.25 -7.07692763e-01 -6.56157682e-01 9.65076137e-01 -2.39396298 0.26071148 415.50 -7.82619377e-01 -1.34374618e+00 1.55503919e+00 -2.09818612 0.20700058 415.75 -1.28706609e+00 -1.16854178e+00 1.73839841e+00 -2.40442385 0.21516899 416.00 -9.10118473e-01 -1.37165005e+00 1.64612864e+00 -2.15661793 0.15024449 416.25 -5.13422841e-01 -3.86408741e-01 6.42584413e-01 -2.49642128 0.03119438 416.50 -1.06348850e-01 9.60187810e-01 9.66059371e-01 1.68110511 0.07285949 416.75 -6.60887123e-01 1.68421494e+00 1.80924066e+00 1.94473447 0.28484532 417.00 -1.42688832e+00 2.30317671e+00 2.70936030e+00 2.12545288 0.51168327 417.25 -1.87377372e+00 2.11345820e+00 2.82448819e+00 2.29615374 0.55099576 417.50 -2.35344996e+00 1.53824784e+00 2.81157129e+00 2.56268103 0.75598007 417.75 -2.61992257e+00 7.40853600e-01 2.72265649e+00 2.86601079 0.73083948 418.00 -3.17379203e+00 8.95264523e-02 3.17505446e+00 3.11339209 0.78745635 418.25 -3.94719629e+00 -9.89339521e-03 3.94720869e+00 -3.13908622 0.82681085 418.50 -4.41649202e+00 -2.51845686e-01 4.42366681e+00 -3.08463042 0.85921668 418.75 -4.61079206e+00 -1.19371178e+00 4.76280918e+00 -2.88825975 0.79984460 419.00 -4.88685692e+00 -1.57446003e+00 5.13422778e+00 -2.82991115 0.85609278 419.25 -5.18541071e+00 -2.20724118e+00 5.63563642e+00 -2.73915997 0.88109593 419.50 -5.11682215e+00 -2.77512434e+00 5.82092639e+00 -2.64463934 0.89712673 419.75 -4.32337434e+00 -3.89565324e+00 5.81959447e+00 -2.40818794 0.78536220 420.00 -3.25892608e+00 -5.15136884e+00 6.09567060e+00 -2.13486574 0.71911003 420.25 -1.83474831e+00 -6.16665608e+00 6.43381291e+00 -1.85998302 0.46902857 420.50 -6.44913789e-01 -7.67677091e+00 7.70381239e+00 -1.65460800 0.36325356 420.75 -1.47162110e+00 -6.42063760e+00 6.58712804e+00 -1.79610640 0.11551555 421.00 5.54300575e-02 -3.71409216e+00 3.71450577e+00 -1.55587318 0.02769721 421.25 2.24408452e+00 -1.63337706e-01 2.25002100e+00 -0.07265777 0.00535503 421.50 3.22221995e+00 3.73395341e+00 4.93204922e+00 0.85883125 0.02023464 421.75 4.76970885e+00 1.65285204e+01 1.72029680e+01 1.28985436 0.33353401 422.00 5.94512005e+00 1.42806839e+01 1.54687552e+01 1.17631342 0.45061117 422.25 3.11267954e+00 1.27827546e+01 1.31562756e+01 1.33193878 0.64589666 422.50 4.61430353e-01 1.04742401e+01 1.04843990e+01 1.52677097 0.67548409 422.75 -3.15359408e+00 8.08785418e+00 8.68092972e+00 1.94258060 0.88051040 423.00 -3.94971920e+00 6.98719272e+00 8.02627833e+00 2.08529497 0.90752409 423.25 -5.72525645e+00 5.89830443e+00 8.22000952e+00 2.34130790 0.91354378 423.50 -6.87490969e+00 5.17088732e+00 8.60246818e+00 2.49672402 0.91392270 423.75 -7.88949739e+00 4.60155323e+00 9.13337075e+00 2.61358002 0.91729101 424.00 -8.04475969e+00 4.59363466e+00 9.26388891e+00 2.62276247 0.91480309 424.25 -8.27539137e+00 4.30276782e+00 9.32715997e+00 2.66211481 0.90327524 424.50 -8.28387984e+00 4.20639563e+00 9.29066356e+00 2.67173975 0.85556792 424.75 -8.56336412e+00 5.31986464e+00 1.00812779e+01 2.58570507 0.76513416 425.00 -8.42203522e+00 6.36743518e+00 1.05581678e+01 2.49423414 0.80977722 425.25 -7.68801588e+00 7.47926214e+00 1.07259009e+01 2.36995705 0.87695201 425.50 -6.66960413e+00 7.30572939e+00 9.89228493e+00 2.31070817 0.86445681 425.75 -5.74029554e+00 7.33259817e+00 9.31224939e+00 2.23498967 0.89363919 426.00 -4.71608108e+00 6.51630903e+00 8.04386127e+00 2.19727487 0.89996567 426.25 -4.14542629e+00 6.16318369e+00 7.42761014e+00 2.16290308 0.94009004 426.50 -3.65193237e+00 5.73693780e+00 6.80066654e+00 2.13766868 0.93991245 426.75 -3.43126760e+00 5.39859149e+00 6.39674819e+00 2.13697165 0.95531955 427.00 -2.92101130e+00 4.62978360e+00 5.47423083e+00 2.13363958 0.93513148 427.25 -2.86302811e+00 3.92217934e+00 4.85596754e+00 2.20134701 0.95720429 427.50 -2.77730073e+00 3.55896772e+00 4.51438264e+00 2.23345072 0.96641874 427.75 -2.47464603e+00 3.19242526e+00 4.03923904e+00 2.23020746 0.96427820 428.00 -2.24473364e+00 2.82349893e+00 3.60707296e+00 2.24249233 0.93814337 428.25 -2.02760876e+00 2.64853563e+00 3.33555667e+00 2.22418069 0.94656682 428.50 -1.71767482e+00 2.30153569e+00 2.87184145e+00 2.21193604 0.90356562 428.75 -1.26853854e+00 1.95391200e+00 2.32958412e+00 2.14663015 0.85122195 429.00 -9.40773899e-01 7.59037798e-01 1.20879854e+00 2.46270531 0.37617150 429.25 -1.02658613e+00 -2.51227525e-01 1.05687953e+00 -2.90158829 0.23621083 429.50 -2.88909817e+00 1.01215604e-01 2.89087060e+00 3.10657334 0.58044735 429.75 -3.98168881e+00 5.59095642e-01 4.02075040e+00 3.00208804 0.80953013 430.00 -3.58133980e+00 8.15227336e-01 3.67295390e+00 2.91777451 0.90344804 430.25 -3.15829071e+00 9.01790514e-01 3.28451311e+00 2.86346228 0.93677303 430.50 -2.57500615e+00 7.63437271e-01 2.68579470e+00 2.85336853 0.90156828 430.75 -2.42340663e+00 5.30842103e-01 2.48086538e+00 2.92595069 0.90129717 431.00 -2.45813961e+00 -1.47251954e-01 2.46254614e+00 -3.08176033 0.88849228 431.25 -2.56192672e+00 -5.44005512e-01 2.61904763e+00 -2.93235811 0.92550915 431.50 -3.18558716e+00 -7.83250581e-01 3.28046445e+00 -2.90050177 0.91930413 431.75 -3.69706978e+00 -6.02073584e-01 3.74577329e+00 -2.98015825 0.93213271 432.00 -4.08316272e+00 2.59792586e-01 4.09141907e+00 3.07805297 0.94321100 432.25 -4.05335697e+00 7.55587758e-01 4.12318028e+00 2.95729754 0.94844763 432.50 -3.32396045e+00 1.40661362e+00 3.60933165e+00 2.74126967 0.93683106 432.75 -2.83911027e+00 1.45852133e+00 3.19183827e+00 2.66702559 0.93756948 433.00 -2.01051187e+00 1.38439528e+00 2.44104655e+00 2.53857331 0.92653474 433.25 -1.77053795e+00 1.16097349e+00 2.11723028e+00 2.56120829 0.91964298 433.50 -1.58566703e+00 8.22447186e-01 1.78626966e+00 2.66311624 0.91816916 433.75 -1.48406724e+00 6.21533218e-01 1.60896212e+00 2.74498180 0.88581059 434.00 -1.29113078e+00 3.37929181e-01 1.33462161e+00 2.88560372 0.83427325 434.25 -1.25750819e+00 2.13888413e-01 1.27556854e+00 2.97311592 0.80710266 434.50 -1.18770283e+00 2.51093384e-02 1.18796822e+00 3.12045471 0.83200881 434.75 -1.25961337e+00 -6.57897122e-02 1.26133030e+00 -3.08940999 0.78925316 435.00 -1.42604589e+00 1.74775350e-01 1.43671615e+00 3.01964141 0.77073475 435.25 -1.39282629e+00 4.22974681e-01 1.45563480e+00 2.84676236 0.77848926 435.50 -1.18714287e+00 6.42316925e-01 1.34977007e+00 2.64563815 0.75294775 435.75 -9.42900019e-01 8.58863487e-01 1.27542422e+00 2.40280198 0.71320881 436.00 -6.29761866e-01 9.90097439e-01 1.17341082e+00 2.13730975 0.78348794 436.25 -3.17471029e-01 1.03070696e+00 1.07849186e+00 1.86958809 0.70520327 436.50 5.19316097e-02 1.00911338e+00 1.01044876e+00 1.51937907 0.77947031 436.75 2.63408817e-01 1.00206533e+00 1.03610768e+00 1.31374570 0.70142253 437.00 7.42632059e-01 9.71185057e-01 1.22258038e+00 0.91797495 0.79577248 437.25 1.02036730e+00 8.27962508e-01 1.31402867e+00 0.68167517 0.80566093 437.50 1.28051850e+00 6.97292851e-01 1.45806205e+00 0.49864119 0.84911365 437.75 1.44764052e+00 5.94207419e-01 1.56484681e+00 0.38949623 0.84834259 438.00 1.64907327e+00 5.72173856e-01 1.74551585e+00 0.33397018 0.88135076 438.25 1.91380710e+00 7.11404080e-01 2.04175253e+00 0.35589366 0.83530732 438.50 2.15993433e+00 8.34824478e-01 2.31565287e+00 0.36881852 0.86902891 438.75 2.46598627e+00 8.28695113e-01 2.60150415e+00 0.32419371 0.82882631 439.00 2.96755691e+00 1.00457175e+00 3.13297916e+00 0.32640957 0.85525275 439.25 3.27835620e+00 1.25585989e+00 3.51066994e+00 0.36583221 0.82103451 439.50 3.69997294e+00 1.41584702e+00 3.96161868e+00 0.36547294 0.83776972 439.75 3.82945409e+00 1.16347885e+00 4.00229955e+00 0.29496106 0.74364318 440.00 4.41748762e+00 1.30839185e+00 4.60717767e+00 0.28795277 0.77149043 440.25 4.76419586e+00 2.21099181e+00 5.25224209e+00 0.43450508 0.77091483 440.50 4.94804809e+00 2.99175000e+00 5.78219232e+00 0.54381869 0.79945021 440.75 4.02919418e+00 3.48534509e+00 5.32747934e+00 0.71315122 0.59851317 441.00 2.87164403e+00 4.91883833e+00 5.69572735e+00 1.04236979 0.50002482 441.25 1.16465381e+00 3.97251850e+00 4.13972484e+00 1.28561022 0.16923101 441.50 2.51385306e+00 2.71832506e+00 3.70253269e+00 0.82445800 0.09654271 441.75 5.83277696e+00 4.28954881e+00 7.24027044e+00 0.63410531 0.38587592 442.00 5.78870310e+00 5.01772386e+00 7.66072035e+00 0.71417433 0.46525179 442.25 4.05361207e+00 5.90390662e+00 7.16155599e+00 0.96912155 0.55500293 442.50 3.23858527e+00 5.78291062e+00 6.62800798e+00 1.06028756 0.57125335 442.75 1.96496123e+00 6.20253739e+00 6.50634634e+00 1.26399921 0.66336140 443.00 1.74621561e+00 5.44391043e+00 5.71711726e+00 1.26039965 0.67518284 443.25 1.01533709e+00 2.36381850e+00 2.57265375e+00 1.16509280 0.46674201 443.50 -5.06656538e-01 2.29867180e+00 2.35384641e+00 1.78774028 0.59038668 443.75 -1.46665312e+00 2.42054739e+00 2.83021573e+00 2.11555591 0.77402267 444.00 -1.88430597e+00 2.02821183e+00 2.76843859e+00 2.31943018 0.77993668 444.25 -2.23208411e+00 1.32791505e+00 2.59722118e+00 2.60491564 0.78649274 444.50 -2.12950988e+00 9.70753349e-01 2.34033638e+00 2.71387820 0.78799510 444.75 -1.71318381e+00 5.25205195e-01 1.79188149e+00 2.84412226 0.72188689 445.00 -1.49675901e+00 1.72458058e-01 1.50666165e+00 3.02687752 0.62867310 445.25 -1.57506162e+00 -2.69240219e-01 1.59790782e+00 -2.97228954 0.62760356 445.50 -1.55777210e+00 -6.42850010e-01 1.68520327e+00 -2.75020950 0.57326450 445.75 -1.25559027e+00 -1.32746881e+00 1.82720562e+00 -2.32837476 0.54949391 446.00 -1.31719391e+00 -1.95013382e+00 2.35330017e+00 -2.16484663 0.67790360 446.25 -1.78398838e+00 -2.59382822e+00 3.14810409e+00 -2.17327515 0.89169744 446.50 -1.90559271e+00 -2.96965966e+00 3.52847872e+00 -2.14130556 0.88693105 446.75 -2.07986281e+00 -3.25520994e+00 3.86292907e+00 -2.13935258 0.85005420 447.00 -2.66217733e+00 -3.87348775e+00 4.70011654e+00 -2.17293544 0.84997354 447.25 -2.98331483e+00 -4.10488591e+00 5.07447098e+00 -2.19926482 0.89968973 447.50 -3.36078973e+00 -3.94307950e+00 5.18100218e+00 -2.27663929 0.89547665 447.75 -3.57080274e+00 -4.07824869e+00 5.42058526e+00 -2.28995053 0.93710567 448.00 -3.94354949e+00 -4.21075032e+00 5.76905546e+00 -2.32343812 0.92666569 448.25 -4.00687795e+00 -4.35750017e+00 5.91970258e+00 -2.31430051 0.92470696 448.50 -3.92799310e+00 -4.53294934e+00 5.99806298e+00 -2.28481609 0.94193652 448.75 -4.01349330e+00 -4.58632154e+00 6.09446254e+00 -2.28968337 0.94538297 449.00 -4.15251780e+00 -4.65122991e+00 6.23516991e+00 -2.29960726 0.90238427 449.25 -4.31980269e+00 -5.05879687e+00 6.65222677e+00 -2.27756117 0.88308887 449.50 -4.49212267e+00 -5.05327227e+00 6.76126665e+00 -2.29747461 0.77720275 449.75 -4.97974868e+00 -5.29942454e+00 7.27198716e+00 -2.32510514 0.78000681 450.00 -5.12764567e+00 -4.46854245e+00 6.80151613e+00 -2.42477065 0.77941638 450.25 -4.84741999e+00 -4.12240984e+00 6.36331230e+00 -2.43684680 0.80061562 450.50 -3.81446042e+00 -3.22412391e+00 4.99450530e+00 -2.43987014 0.84596130 450.75 -3.24883963e+00 -3.10764880e+00 4.49582473e+00 -2.37840292 0.87178033 451.00 -2.26954514e+00 -2.46662566e+00 3.35187668e+00 -2.31460670 0.88512796 451.25 -1.93550472e+00 -2.50378486e+00 3.16466699e+00 -2.22887543 0.89835059 451.50 -1.45921004e+00 -2.61071462e+00 2.99084015e+00 -2.08047069 0.83999177 451.75 -1.30424616e+00 -2.80629871e+00 3.09457113e+00 -2.00585394 0.86002738 452.00 -1.65575359e+00 -2.60601731e+00 3.08753076e+00 -2.13680934 0.85718886 452.25 -1.75969287e+00 -2.37392314e+00 2.95500086e+00 -2.20867995 0.87591627 452.50 -1.87410981e+00 -1.83831883e+00 2.62520546e+00 -2.36583504 0.85649321 452.75 -1.90177609e+00 -1.48688838e+00 2.41404005e+00 -2.47802216 0.81085322 453.00 -1.55986053e+00 -1.46826121e+00 2.14218483e+00 -2.38643482 0.85282834 453.25 -1.44579766e+00 -1.60731209e+00 2.16189338e+00 -2.30334214 0.90170992 453.50 -1.20084964e+00 -1.72006448e+00 2.09777541e+00 -2.18027437 0.86250951 453.75 -1.25346868e+00 -1.79464658e+00 2.18905004e+00 -2.18048043 0.82698183 454.00 -1.42711299e+00 -2.08235280e+00 2.52444938e+00 -2.17161327 0.85001456 454.25 -1.44748753e+00 -2.18985887e+00 2.62501467e+00 -2.15486267 0.86049635 454.50 -1.82444594e+00 -2.43988674e+00 3.04658010e+00 -2.21286130 0.91198310 454.75 -1.92075923e+00 -2.47707979e+00 3.13452394e+00 -2.23036421 0.88993010 455.00 -2.41624893e+00 -2.91332149e+00 3.78493078e+00 -2.26319661 0.84608305 455.25 -2.95659471e+00 -2.57057370e+00 3.91781846e+00 -2.42592191 0.83679378 455.50 -3.38914100e+00 -2.09456252e+00 3.98415221e+00 -2.58802722 0.84191270 455.75 -3.52130326e+00 -2.06659168e+00 4.08293740e+00 -2.61087412 0.84111169 456.00 -3.53867821e+00 -1.31393409e+00 3.77474055e+00 -2.78606408 0.83584383 456.25 -3.49319831e+00 -8.95308887e-01 3.60610766e+00 -2.89069284 0.87146583 456.50 -3.63289085e+00 -8.38445999e-01 3.72838941e+00 -2.91477118 0.94350081 456.75 -3.53079721e+00 -5.39450827e-01 3.57176933e+00 -2.98998067 0.94314211 457.00 -3.34641470e+00 -4.21848183e-01 3.37289894e+00 -3.01619435 0.96177808 457.25 -3.28364394e+00 -4.07440485e-01 3.30882536e+00 -3.01814182 0.96256935 457.50 -3.17606277e+00 -3.15575981e-01 3.19170220e+00 -3.04255696 0.96219595 457.75 -2.94468937e+00 -2.66510605e-01 2.95672512e+00 -3.05133306 0.96968934 458.00 -2.83261630e+00 -3.23860470e-01 2.85107010e+00 -3.02775434 0.98032664 458.25 -2.82856376e+00 -4.50388524e-01 2.86419671e+00 -2.98368953 0.98330061 458.50 -2.84447450e+00 -4.22797667e-01 2.87572479e+00 -2.99403477 0.99073089 458.75 -2.83339622e+00 -4.41298250e-01 2.86755616e+00 -2.98708514 0.98757850 459.00 -2.86999942e+00 -4.94199467e-01 2.91223793e+00 -2.97106995 0.98517369 459.25 -2.93486584e+00 -4.49151563e-01 2.96903597e+00 -2.98973104 0.98066549 459.50 -3.01601498e+00 -3.83625469e-01 3.04031493e+00 -3.01507589 0.98392799 459.75 -3.10476037e+00 -1.61703773e-01 3.10896849e+00 -3.08955714 0.98018333 460.00 -3.14313085e+00 -8.47965984e-02 3.14427448e+00 -3.11462081 0.98527514 460.25 -3.20720987e+00 1.56996417e-01 3.21105014e+00 3.09268061 0.98455273 460.50 -3.19354836e+00 3.66109755e-01 3.21446535e+00 3.02745052 0.98567609 460.75 -3.07453687e+00 5.77897896e-01 3.12837705e+00 2.95579787 0.98087831 461.00 -2.90795506e+00 7.26858596e-01 2.99741990e+00 2.89665612 0.97965014 461.25 -2.53621394e+00 9.45935327e-01 2.70687547e+00 2.78460165 0.97631415 461.50 -2.32897986e+00 9.58995072e-01 2.51869386e+00 2.75098438 0.98468842 461.75 -2.09350345e+00 8.46311708e-01 2.25809659e+00 2.75742255 0.98137555 462.00 -1.99677085e+00 8.10026521e-01 2.15481712e+00 2.75620943 0.98501449 462.25 -1.79822250e+00 7.85007936e-01 1.96210133e+00 2.72998272 0.98457799 462.50 -1.68140117e+00 7.40392827e-01 1.83719663e+00 2.72679865 0.98251925 462.75 -1.48016748e+00 5.82067341e-01 1.59050249e+00 2.76692374 0.97026752 463.00 -1.37576105e+00 4.50150582e-01 1.44753377e+00 2.82537119 0.97276646 463.25 -1.36346580e+00 3.27470672e-01 1.40223964e+00 2.90588202 0.96464503 463.50 -1.44273210e+00 2.42589582e-01 1.46298518e+00 2.97500500 0.96031645 463.75 -1.46741191e+00 4.82740732e-02 1.46820575e+00 3.10870709 0.96805992 464.00 -1.51197610e+00 3.11067120e-02 1.51229605e+00 3.12102201 0.95919498 464.25 -1.65569808e+00 1.69549104e-02 1.65578489e+00 3.13135267 0.96899980 464.50 -1.64781148e+00 4.19506272e-02 1.64834539e+00 3.11613976 0.96779385 464.75 -1.70988609e+00 1.89211434e-01 1.72032305e+00 3.03138370 0.97490967 465.00 -1.66160752e+00 2.57787248e-01 1.68148560e+00 2.98767643 0.96669029 465.25 -1.54018011e+00 3.29240822e-01 1.57497755e+00 2.93099461 0.97263827 465.50 -1.49051171e+00 2.90158613e-01 1.51849174e+00 2.94932686 0.97029843 465.75 -1.49876927e+00 2.54713584e-01 1.52025930e+00 2.97325255 0.97061390 466.00 -1.51072027e+00 2.94735976e-01 1.53920273e+00 2.94891658 0.97162462 466.25 -1.47207748e+00 3.01285147e-01 1.50259270e+00 2.93971400 0.97435438 466.50 -1.39175156e+00 3.75671528e-01 1.44156217e+00 2.87794872 0.97236368 466.75 -1.32327188e+00 3.53567175e-01 1.36969274e+00 2.88050021 0.98006300 467.00 -1.34913757e+00 3.66296583e-01 1.39797903e+00 2.87647931 0.96832487 467.25 -1.37780253e+00 5.16548295e-01 1.47144893e+00 2.78290321 0.97569054 467.50 -1.29006179e+00 5.89212696e-01 1.41824928e+00 2.71315439 0.98357622 467.75 -1.23617818e+00 6.11925438e-01 1.37934377e+00 2.68194184 0.99155577 468.00 -1.20268070e+00 6.26455543e-01 1.35605583e+00 2.66137881 0.98682404 468.25 -1.14754137e+00 6.44727973e-01 1.31625429e+00 2.62970912 0.98615672 468.50 -1.10996898e+00 7.17192223e-01 1.32151270e+00 2.56793775 0.98193085 468.75 -1.07062506e+00 7.71512735e-01 1.31964765e+00 2.51716207 0.98848743 469.00 -9.92529740e-01 8.31828653e-01 1.29501127e+00 2.44405408 0.98044841 469.25 -9.07041956e-01 9.01501030e-01 1.27883901e+00 2.35925823 0.98001000 469.50 -8.33491064e-01 9.43020431e-01 1.25856859e+00 2.29461825 0.97423906 469.75 -7.62218663e-01 9.88515889e-01 1.24825516e+00 2.22764879 0.98267510 470.00 -7.46349315e-01 1.05782125e+00 1.29461311e+00 2.18523965 0.97583644 470.25 -7.32157363e-01 1.14363091e+00 1.35791976e+00 2.14025440 0.97368636 470.50 -6.05295490e-01 1.28156427e+00 1.41731775e+00 2.01204749 0.96385242 470.75 -5.45133391e-01 1.38901347e+00 1.49215577e+00 1.94478658 0.97698307 471.00 -5.66674639e-01 1.49654446e+00 1.60023919e+00 1.93276787 0.96906241 471.25 -5.85450198e-01 1.60178309e+00 1.70542106e+00 1.92121149 0.96223856 471.50 -5.08779308e-01 1.89519279e+00 1.96229765e+00 1.83307020 0.94699369 471.75 -4.83533170e-01 2.06735941e+00 2.12315314e+00 1.80055542 0.96153760 472.00 -4.73667175e-01 2.51825411e+00 2.56241377e+00 1.75671754 0.94508812 472.25 -3.40265392e-01 2.92022707e+00 2.93998413e+00 1.68679343 0.95076210 472.50 -1.03394730e-01 3.78107319e+00 3.78248661e+00 1.59813485 0.93974815 472.75 1.33574392e-01 4.38578502e+00 4.38781864e+00 1.54034953 0.94961292 473.00 7.38395098e-01 5.26476838e+00 5.31629696e+00 1.43145309 0.91184085 473.25 9.50585879e-01 6.07199521e+00 6.14595308e+00 1.41550433 0.88725155 473.50 2.15029310e+00 7.78182630e+00 8.07344914e+00 1.30120109 0.82145780 473.75 2.93616331e+00 8.61513911e+00 9.10174032e+00 1.24232801 0.79053555 474.00 3.71053219e+00 1.09943672e+01 1.16036270e+01 1.24530592 0.58070771 474.25 3.04902649e+00 1.13758072e+01 1.17773321e+01 1.30892410 0.41024197 474.50 2.48603755e+00 6.28163210e+00 6.75568535e+00 1.19394787 0.06632719 474.75 -4.20523892e+00 8.38812079e-01 4.28808116e+00 2.94470835 0.02471193 475.00 -1.14294017e+01 -6.58337045e+00 1.31898442e+01 -2.61900487 0.48667858 475.25 -9.12016393e+00 -6.13164128e+00 1.09897414e+01 -2.54968847 0.56487107 475.50 -7.00347959e+00 -3.68280343e+00 7.91275978e+00 -2.65747690 0.56123057 475.75 -6.02146412e+00 -2.98875298e+00 6.72240095e+00 -2.68086940 0.65707515 476.00 -4.60032766e+00 -3.26795057e+00 5.64291729e+00 -2.52393853 0.78869316 476.25 -3.98302280e+00 -3.03864051e+00 5.00977113e+00 -2.48988774 0.80896219 476.50 -3.16344452e+00 -2.59142234e+00 4.08935826e+00 -2.45526705 0.78865699 476.75 -2.53502282e+00 -2.30788406e+00 3.42821667e+00 -2.40306147 0.75203375 477.00 -2.03692560e+00 -2.10932216e+00 2.93228680e+00 -2.33873552 0.80793834 477.25 -1.61716318e+00 -2.10124732e+00 2.65150091e+00 -2.22673681 0.80294560 477.50 -1.09863735e+00 -2.04466536e+00 2.32113344e+00 -2.06385147 0.79898865 477.75 -4.93871100e-01 -2.16415491e+00 2.21979169e+00 -1.79515929 0.74944047 478.00 -1.18536878e-01 -2.47091157e+00 2.47375322e+00 -1.61873251 0.83726125 478.25 1.37496001e-01 -2.70436841e+00 2.70786146e+00 -1.51999788 0.82954941 478.50 3.86565984e-01 -3.22085592e+00 3.24397073e+00 -1.45134803 0.88921743 478.75 4.82885313e-01 -3.63738161e+00 3.66929464e+00 -1.43881179 0.86041712 479.00 6.52903515e-01 -4.03016213e+00 4.08270618e+00 -1.41018743 0.91974670 479.25 5.52861817e-01 -4.62007401e+00 4.65303557e+00 -1.45169752 0.88280162 479.50 1.05290774e-01 -5.41339724e+00 5.41442109e+00 -1.55134874 0.94800881 479.75 -4.06862800e-01 -5.73468097e+00 5.74909585e+00 -1.64162541 0.93620084 480.00 -1.04956073e+00 -5.71758305e+00 5.81311738e+00 -1.75234236 0.94879050 480.25 -1.44995242e+00 -5.69218253e+00 5.87395130e+00 -1.82021893 0.94501698 480.50 -1.61327103e+00 -5.94172615e+00 6.15684604e+00 -1.83592019 0.94155784 480.75 -2.45216570e+00 -5.77692047e+00 6.27582080e+00 -1.97222329 0.91098391 481.00 -2.90793996e+00 -5.80100651e+00 6.48905165e+00 -2.03546898 0.90908173 481.25 -4.00416473e+00 -5.81735390e+00 7.06221931e+00 -2.17363604 0.88132547 481.50 -4.90839709e+00 -5.38675725e+00 7.28762757e+00 -2.30976329 0.87991858 481.75 -5.13915681e+00 -3.14841750e+00 6.02689518e+00 -2.59193587 0.81145669 482.00 -5.04985730e+00 -2.04386344e+00 5.44779190e+00 -2.75700945 0.83717230 482.25 -3.54449245e+00 -1.99548755e+00 4.06760338e+00 -2.62883667 0.84746254 482.50 -3.15633365e+00 -2.15238812e+00 3.82036866e+00 -2.54309970 0.87397944 482.75 -2.89260684e+00 -2.89849372e+00 4.09492860e+00 -2.35517795 0.83963285 483.00 -3.60471500e+00 -3.30578587e+00 4.89103163e+00 -2.39942477 0.85070725 483.25 -4.95262898e+00 -3.11356916e+00 5.85002964e+00 -2.58035860 0.87320317 483.50 -5.24060786e+00 -2.61028724e+00 5.85470496e+00 -2.67947530 0.88565050 483.75 -6.01288911e+00 -2.23833158e+00 6.41599281e+00 -2.78523021 0.88415902 484.00 -6.43920733e+00 -1.53764789e+00 6.62025317e+00 -2.90718774 0.87733039 484.25 -5.91032800e+00 1.25838155e+00 6.04280574e+00 2.93181280 0.84596807 484.50 -4.75282972e+00 2.44220603e+00 5.34357190e+00 2.66693245 0.86204584 484.75 -2.97235588e+00 1.65141285e+00 3.40030350e+00 2.63446741 0.85003552 485.00 -2.59479998e+00 9.97372631e-01 2.77988113e+00 2.77462946 0.81701561 485.25 -3.03692195e+00 -4.43078563e-01 3.06907373e+00 -2.99671757 0.81558559 485.50 -3.53318950e+00 -6.17010493e-01 3.58666001e+00 -2.96870338 0.87736574 485.75 -4.63589598e+00 -4.19542262e-01 4.65484127e+00 -3.05133987 0.86477778 486.00 -5.03649892e+00 6.10061025e-01 5.07331211e+00 3.02105189 0.84467509 486.25 -4.56709410e+00 2.23515076e+00 5.08470721e+00 2.68645831 0.90417252 486.50 -3.92512033e+00 2.45345975e+00 4.62882646e+00 2.58294579 0.87051160 486.75 -2.88831359e+00 2.66648781e+00 3.93096841e+00 2.39610734 0.89980983 487.00 -2.46174873e+00 2.54476745e+00 3.54062822e+00 2.33961388 0.88056495 487.25 -1.75915878e+00 2.48119613e+00 3.04154136e+00 2.18753457 0.88500024 487.50 -1.58874887e+00 2.47121840e+00 2.93786374e+00 2.14216486 0.90061714 487.75 -1.68053565e+00 2.47872439e+00 2.99470777e+00 2.16659318 0.91580789 488.00 -1.46541519e+00 2.56626068e+00 2.95518790e+00 2.08964291 0.89442865 488.25 -1.18694400e+00 2.47004433e+00 2.74042972e+00 2.01875144 0.89689652 488.50 -9.53015017e-01 2.37420465e+00 2.55833644e+00 1.95251238 0.86320038 488.75 -8.72027364e-01 2.17617668e+00 2.34439260e+00 1.95191922 0.87872395 489.00 -8.38157147e-01 2.26016540e+00 2.41057151e+00 1.92591389 0.84692677 489.25 -8.50562449e-01 2.58088576e+00 2.71743037e+00 1.88914905 0.88401910 489.50 -7.12866095e-01 2.91546216e+00 3.00134931e+00 1.81060338 0.89344678 489.75 -4.12075498e-01 3.21056256e+00 3.23689947e+00 1.69844835 0.93293981 490.00 2.72805101e-01 3.55234292e+00 3.56280267e+00 1.49415094 0.91515019 490.25 7.89628491e-01 3.82477476e+00 3.90543405e+00 1.36720567 0.94795913 490.50 1.47085225e+00 3.76179448e+00 4.03912169e+00 1.19807473 0.94081294 490.75 2.11154656e+00 3.54882887e+00 4.12950545e+00 1.03406279 0.95239184 491.00 2.70443766e+00 3.08947646e+00 4.10595274e+00 0.85175632 0.95539582 491.25 3.15663384e+00 2.74325062e+00 4.18207618e+00 0.71544616 0.95751946 491.50 3.51542610e+00 2.05908740e+00 4.07407187e+00 0.52986011 0.95824064 491.75 3.74361810e+00 1.73632852e+00 4.12668308e+00 0.43427901 0.97140893 492.00 3.73374994e+00 1.20548558e+00 3.92352954e+00 0.31229684 0.96855367 492.25 3.77138424e+00 9.06429627e-01 3.87878251e+00 0.23587023 0.97739743 492.50 3.72760193e+00 5.37546765e-01 3.76616153e+00 0.14321979 0.97477485 492.75 3.79563667e+00 3.20118472e-01 3.80911191e+00 0.08413943 0.97959885 493.00 3.90868301e+00 -1.06971707e-01 3.91014652e+00 -0.02736088 0.98385834 493.25 3.92043914e+00 -3.09976754e-01 3.93267449e+00 -0.07890270 0.98715620 493.50 3.84661402e+00 -6.99661333e-01 3.90972703e+00 -0.17992320 0.98301361 493.75 3.82865076e+00 -8.80023901e-01 3.92848682e+00 -0.22592803 0.98761083 494.00 3.79625864e+00 -1.16474887e+00 3.97092175e+00 -0.29769725 0.98423705 494.25 3.76758132e+00 -1.38541133e+00 4.01422888e+00 -0.35237212 0.98313454 494.50 3.62165265e+00 -1.76093749e+00 4.02706702e+00 -0.45256688 0.98036210 494.75 3.51388930e+00 -1.95277592e+00 4.02004376e+00 -0.50723228 0.98107337 495.00 3.20835114e+00 -2.29314002e+00 3.94360346e+00 -0.62055088 0.98089867 495.25 3.07194386e+00 -2.49154157e+00 3.95532786e+00 -0.68145067 0.97975880 495.50 2.78082367e+00 -2.78171455e+00 3.93330855e+00 -0.78555832 0.97923453 495.75 2.52114302e+00 -2.81680109e+00 3.78028181e+00 -0.84072963 0.97419706 496.00 2.10665396e+00 -2.93157986e+00 3.61000712e+00 -0.94769126 0.96977257 496.25 1.79369750e+00 -2.89884648e+00 3.40890916e+00 -1.01669498 0.95935478 496.50 1.26181337e+00 -2.80573197e+00 3.07641104e+00 -1.14816947 0.95557578 496.75 1.11472450e+00 -2.51017951e+00 2.74656365e+00 -1.15287504 0.93622395 497.00 9.87181909e-01 -2.20772886e+00 2.41838682e+00 -1.15031652 0.93698196 497.25 1.04638527e+00 -2.08741590e+00 2.33500049e+00 -1.10612316 0.92594607 497.50 9.99574973e-01 -1.83303507e+00 2.08786199e+00 -1.07155991 0.90589355 497.75 1.01261978e+00 -1.70455532e+00 1.98265167e+00 -1.03475087 0.89189611 498.00 1.03748758e+00 -1.55587178e+00 1.87005814e+00 -0.98268706 0.92848679 498.25 1.01298251e+00 -1.45321505e+00 1.77143093e+00 -0.96204419 0.92238142 498.50 1.15756956e+00 -1.24429892e+00 1.69948436e+00 -0.82149160 0.93828047 498.75 1.28886256e+00 -1.32144481e+00 1.84590983e+00 -0.79787967 0.92025511 499.00 1.44419103e+00 -1.45154732e+00 2.04760283e+00 -0.78793854 0.92407754 499.25 1.31396467e+00 -1.40404675e+00 1.92297957e+00 -0.81852868 0.91948316 499.50 1.22813890e+00 -1.29352205e+00 1.78368283e+00 -0.81132096 0.94117860 499.75 1.20591158e+00 -1.28607195e+00 1.76300987e+00 -0.81755437 0.92124366 500.00 1.19213220e+00 -1.09784590e+00 1.62063099e+00 -0.74424796 0.89087471 500.25 1.32060646e+00 -9.11939172e-01 1.60487833e+00 -0.60435261 0.86947730 500.50 1.38589807e+00 -7.72249090e-01 1.58653147e+00 -0.50836892 0.91667490 500.75 1.44352798e+00 -5.42770659e-01 1.54219747e+00 -0.35964961 0.89156946 501.00 1.57929482e+00 -3.91950895e-01 1.62720546e+00 -0.24326589 0.91451871 501.25 1.73475196e+00 -3.24251088e-01 1.76479550e+00 -0.18478272 0.87946808 501.50 1.82826231e+00 -1.60551587e-01 1.83529831e+00 -0.08759179 0.88256359 501.75 2.01145625e+00 -2.87633177e-02 2.01166189e+00 -0.01429877 0.90984779 502.00 2.16475718e+00 4.10221390e-02 2.16514583e+00 0.01894773 0.92643668 502.25 2.44629372e+00 3.41523603e-01 2.47001849e+00 0.13871203 0.93649386 502.50 2.68335794e+00 4.52154541e-01 2.72118605e+00 0.16693509 0.95898848 502.75 3.12860247e+00 4.87840445e-01 3.16640833e+00 0.15468356 0.96890743 503.00 3.33281460e+00 4.91389391e-01 3.36884501e+00 0.14638511 0.97525488 503.25 3.88642353e+00 3.01407058e-01 3.89809364e+00 0.07739891 0.96954635 503.50 4.26349568e+00 2.37111312e-01 4.27008397e+00 0.05555707 0.98230869 503.75 4.62386315e+00 -7.17466430e-02 4.62441975e+00 -0.01551536 0.98207684 504.00 4.67672113e+00 -2.93872911e-01 4.68594513e+00 -0.06275487 0.98460329 504.25 4.59572103e+00 -4.92259475e-01 4.62200943e+00 -0.10670573 0.98375068 504.50 4.71693338e+00 -3.85331267e-01 4.73264627e+00 -0.08151006 0.98510728 504.75 5.02712664e+00 -2.23212291e-01 5.03207969e+00 -0.04437242 0.98989944 505.00 5.20516412e+00 -2.61656734e-01 5.21173654e+00 -0.05022640 0.98737631 505.25 5.65298705e+00 -3.83296352e-01 5.66596671e+00 -0.06770059 0.98095821 505.50 5.85164278e+00 -5.94965597e-01 5.88181157e+00 -0.10132676 0.98224705 505.75 6.24398734e+00 -1.11283904e+00 6.34238036e+00 -0.17637380 0.98630931 506.00 6.28316481e+00 -1.31665414e+00 6.41963691e+00 -0.20656375 0.98440813 506.25 5.90895518e+00 -1.75301267e+00 6.16350588e+00 -0.28839941 0.97111231 506.50 5.43303400e+00 -1.68253192e+00 5.68759810e+00 -0.30031873 0.95142495 506.75 4.66016379e+00 -8.74328889e-01 4.74147419e+00 -0.18546158 0.87387944 507.00 4.47016173e+00 5.08804581e-01 4.49902522e+00 0.11333465 0.83525092 507.25 5.73554903e+00 2.37330306e+00 6.20718053e+00 0.39233604 0.91259266 507.50 6.69364818e+00 3.10571628e+00 7.37905140e+00 0.43441837 0.92650781 507.75 8.78770830e+00 4.06387988e+00 9.68188705e+00 0.43315937 0.93531795 508.00 1.04588535e+01 4.59390949e+00 1.14232929e+01 0.41386697 0.92267988 508.25 1.30396547e+01 5.62472904e+00 1.42010624e+01 0.40724162 0.93232450 508.50 1.46535036e+01 6.09731607e+00 1.58714344e+01 0.39430779 0.89548320 508.75 1.71016204e+01 7.45951052e+00 1.86576986e+01 0.41130815 0.88883932 509.00 1.91180894e+01 7.95452207e+00 2.07069014e+01 0.39428522 0.75954475 509.25 2.36760180e+01 9.34755195e+00 2.54544801e+01 0.37602510 0.68119211 509.50 2.19000290e+01 9.31974587e+00 2.38006078e+01 0.40234370 0.50466188 509.75 1.22536177e+01 1.24200711e+01 1.74473297e+01 0.79214425 0.22066711 510.00 -2.40115689e+00 9.13149798e+00 9.44191770e+00 1.82792862 0.11266613 510.25 -1.12315238e+01 4.19851576e+00 1.19906073e+01 2.78386100 0.35525454 510.50 -9.04771848e+00 7.43078979e-01 9.07818132e+00 3.05964769 0.40301463 510.75 -7.69665253e+00 -1.32009654e+00 7.80904060e+00 -2.97172977 0.45938696 511.00 -5.44117341e+00 -2.09236944e+00 5.82961216e+00 -2.77448119 0.51425516 511.25 -4.15587645e+00 -2.66986262e+00 4.93958252e+00 -2.57055697 0.65990757 511.50 -3.10643220e+00 -4.21401894e+00 5.23525325e+00 -2.20603306 0.76732123 511.75 -2.51146678e+00 -5.04708009e+00 5.63741810e+00 -2.03252840 0.86644237 512.00 -1.72839564e+00 -5.63302089e+00 5.89222163e+00 -1.86850991 0.84857481 512.25 -1.64575283e+00 -6.32235528e+00 6.53304513e+00 -1.82545185 0.90529043 512.50 -1.99636061e+00 -6.41364011e+00 6.71715975e+00 -1.87255836 0.90004931 512.75 -2.09031707e+00 -6.53610250e+00 6.86221985e+00 -1.88032776 0.92133007 513.00 -1.47454145e+00 -6.45296501e+00 6.61929225e+00 -1.79544535 0.90638901 513.25 -1.23030545e+00 -6.36418012e+00 6.48200896e+00 -1.76175793 0.89958753 513.50 -6.34834516e-02 -6.13007584e+00 6.13040455e+00 -1.58115202 0.87442198 513.75 5.35540028e-01 -6.25111342e+00 6.27401165e+00 -1.48533386 0.92520391 514.00 1.53969560e+00 -6.32405121e+00 6.50878531e+00 -1.33197608 0.90239672 514.25 2.24503352e+00 -6.67416150e+00 7.04163385e+00 -1.24630910 0.89221355 514.50 2.91853153e+00 -7.89084707e+00 8.41328080e+00 -1.21653701 0.82008809 514.75 3.52865236e+00 -8.53347513e+00 9.23426149e+00 -1.17870042 0.78721798 515.00 5.11095142e+00 -9.74039635e+00 1.09998702e+01 -1.08757121 0.73858067 515.25 6.26896151e+00 -9.48717763e+00 1.13712980e+01 -0.98687841 0.63635572 515.50 3.64780280e+00 -8.54074270e+00 9.28712825e+00 -1.16714320 0.29594069 515.75 -2.68728430e-01 -7.59427103e+00 7.59902411e+00 -1.60616725 0.15498356 516.00 -1.02887101e+01 -8.12052700e+00 1.31072695e+01 -2.47343131 0.31887799 516.25 -1.07727468e+01 -4.94824788e+00 1.18548399e+01 -2.71100688 0.29018791 516.50 -1.38792978e+01 1.71503151e+00 1.39848575e+01 3.01864827 0.45486870 516.75 -1.28511719e+01 2.91785505e+00 1.31782585e+01 2.91832811 0.48879169 517.00 -1.01908352e+01 5.25821138e+00 1.14674282e+01 2.66524724 0.61862144 517.25 -8.12365448e+00 5.74403052e+00 9.94925368e+00 2.52613434 0.70992841 517.50 -5.79533102e+00 5.26866096e+00 7.83228255e+00 2.40376076 0.77966326 517.75 -4.63275939e+00 3.59012438e+00 5.86101123e+00 2.48231821 0.73668317 518.00 -3.99751594e+00 2.03412506e+00 4.48528688e+00 2.67089231 0.72710359 518.25 -3.60487365e+00 5.92701711e-01 3.65327379e+00 2.97863385 0.75746249 518.50 -3.82958240e+00 4.63087260e-02 3.82986238e+00 3.12950087 0.94103832 518.75 -3.83849071e+00 -3.23615410e-01 3.85210823e+00 -3.05748357 0.93380738 519.00 -3.96934515e+00 -8.87416492e-01 4.06733438e+00 -2.92164212 0.94567060 519.25 -4.13285984e+00 -1.10310690e+00 4.27754314e+00 -2.88076190 0.94184373 519.50 -4.48299081e+00 -1.35668237e+00 4.68377985e+00 -2.84772581 0.95427668 519.75 -4.77250144e+00 -1.46960711e+00 4.99364747e+00 -2.84287455 0.95136805 520.00 -5.20351213e+00 -1.50550723e+00 5.41692630e+00 -2.85995779 0.95042550 520.25 -5.52433516e+00 -1.18981719e+00 5.65101264e+00 -2.92945575 0.92591208 520.50 -6.19202811e+00 -6.35081483e-01 6.22451127e+00 -3.03938567 0.93051641 520.75 -6.53777888e+00 8.90408288e-01 6.59813455e+00 3.00623118 0.88083179 521.00 -6.20821759e+00 2.85280184e+00 6.83230883e+00 2.71084993 0.91037119 521.25 -4.68610487e+00 3.82914389e+00 6.05160489e+00 2.45649518 0.81605537 521.50 -2.49322082e+00 5.18476494e+00 5.75308070e+00 2.01902674 0.70715927 521.75 1.25160043e+00 4.99141317e+00 5.14594103e+00 1.32511123 0.63378926 522.00 3.31151066e+00 3.21375365e+00 4.61457640e+00 0.77041797 0.61655189 522.25 4.66333465e+00 -7.24359752e-01 4.71925705e+00 -0.15409938 0.55994937 522.50 4.06888519e+00 -3.37693494e+00 5.28767588e+00 -0.69273294 0.67311419 522.75 2.84340916e+00 -5.05826735e+00 5.80267561e+00 -1.05868718 0.64658582 523.00 2.12103583e+00 -6.59722182e+00 6.92980005e+00 -1.25972932 0.61540993 523.25 1.53293412e+00 -8.79209739e+00 8.92473325e+00 -1.39817789 0.46737847 523.50 -4.14547327e-01 -1.04743436e+01 1.04825438e+01 -1.61035309 0.40553385 523.75 -6.23358012e+00 -8.06094319e+00 1.01900111e+01 -2.22904753 0.20274792 524.00 -1.28654698e+01 2.96565553e+00 1.32028567e+01 2.91503728 0.29506137 524.25 -1.12333657e+01 8.26792473e+00 1.39480136e+01 2.50710224 0.63555365 524.50 -8.88649910e+00 9.00244939e+00 1.26496625e+01 2.34971291 0.70839205 524.75 -5.56961637e+00 9.29882800e+00 1.08392264e+01 2.11045001 0.81078602 525.00 -4.64872174e+00 9.16086631e+00 1.02728811e+01 2.04038964 0.85573968 525.25 -3.38279768e+00 7.61309105e+00 8.33081481e+00 1.98893309 0.90535966 525.50 -2.73634930e+00 7.18815477e+00 7.69137026e+00 1.93453285 0.92245843 525.75 -2.28785794e+00 6.01027697e+00 6.43099707e+00 1.93451788 0.93077356 526.00 -2.28042330e+00 5.63105664e+00 6.07528841e+00 1.95558201 0.93822253 526.25 -2.13407190e+00 5.28091811e+00 5.69581943e+00 1.95484079 0.93188804 526.50 -2.07874760e+00 5.03996026e+00 5.45182455e+00 1.96199189 0.91384359 526.75 -2.83007655e+00 4.29597995e+00 5.14439278e+00 2.15331431 0.84604027 527.00 -3.32440171e+00 3.70149045e+00 4.97520636e+00 2.30257464 0.83866850 527.25 -4.03574680e+00 2.91000518e+00 4.97547810e+00 2.51687355 0.74315485 527.50 -4.36827308e+00 1.36273683e+00 4.57590006e+00 2.83919766 0.55288580 527.75 -3.44152311e+00 -2.84884961e+00 4.46766443e+00 -2.45013630 0.63038348 528.00 -2.26552563e+00 -3.46621976e+00 4.14092813e+00 -2.14969903 0.65368515 528.25 -1.06821307e+00 -3.14851876e+00 3.32479316e+00 -1.89788464 0.70817768 528.50 -4.58501598e-01 -2.85762824e+00 2.89417740e+00 -1.72988867 0.72447433 528.75 3.98308664e-01 -2.28820582e+00 2.32261397e+00 -1.39845288 0.77819228 529.00 6.78039326e-01 -1.89425037e+00 2.01194478e+00 -1.22706029 0.73778999 529.25 1.19776069e+00 -1.67345726e+00 2.05793340e+00 -0.94958438 0.83033630 529.50 1.14799243e+00 -1.82602008e+00 2.15690425e+00 -1.00955112 0.79452507 529.75 5.53420368e-01 -1.87216667e+00 1.95225053e+00 -1.28337722 0.79475561 530.00 4.83236275e-01 -1.55496310e+00 1.62832047e+00 -1.26948809 0.78862094 530.25 5.57646505e-01 -1.29656933e+00 1.41140415e+00 -1.16461906 0.84515418 530.50 5.02998259e-01 -1.16914461e+00 1.27275542e+00 -1.16450622 0.79985432 530.75 4.36371028e-01 -1.01056478e+00 1.10075467e+00 -1.16317251 0.79097230 531.00 5.58159677e-01 -8.18062508e-01 9.90337565e-01 -0.97205224 0.81114265 531.25 5.97198716e-01 -7.29935453e-01 9.43107667e-01 -0.88508421 0.86359861 531.50 5.46486896e-01 -6.36643848e-01 8.39025218e-01 -0.86145320 0.82019347 531.75 5.06390622e-01 -5.29356595e-01 7.32563899e-01 -0.80756787 0.83261734 532.00 5.77345033e-01 -2.98819450e-01 6.50092571e-01 -0.47760868 0.63182230 532.25 7.58287250e-01 1.58389444e-02 7.58452652e-01 0.02088475 0.77639479 532.50 9.55708311e-01 2.40609254e-01 9.85530917e-01 0.24663457 0.80679353 532.75 1.08512155e+00 4.26478984e-01 1.16592157e+00 0.37447829 0.88002922 533.00 1.64599131e+00 5.44163873e-01 1.73360945e+00 0.31928807 0.86686836 533.25 2.09265437e+00 4.65748034e-01 2.14385717e+00 0.21899394 0.92784310 533.50 2.63671353e+00 1.69911587e-01 2.64218247e+00 0.06435169 0.90906978 533.75 3.09681716e+00 -9.05209301e-02 3.09813985e+00 -0.02922199 0.93815620 534.00 3.19652055e+00 -6.46693244e-01 3.26128131e+00 -0.19961728 0.90894032 534.25 3.20909209e+00 -1.20863688e+00 3.42915079e+00 -0.36019800 0.92522392 534.50 3.24461194e+00 -1.82074198e+00 3.72056554e+00 -0.51136991 0.94544093 534.75 3.08791103e+00 -2.14521913e+00 3.75994144e+00 -0.60717039 0.95168421 535.00 2.70754991e+00 -2.54385177e+00 3.71510543e+00 -0.75423598 0.94505865 535.25 2.49222318e+00 -2.80045995e+00 3.74883346e+00 -0.84357074 0.95615550 535.50 2.16996712e+00 -3.05959222e+00 3.75098145e+00 -0.95389983 0.96102062 535.75 1.96818675e+00 -3.19907183e+00 3.75603776e+00 -1.01924856 0.95399857 536.00 1.64300203e+00 -3.73243026e+00 4.07804994e+00 -1.15612500 0.91648713 536.25 1.17401921e+00 -3.70406831e+00 3.88567151e+00 -1.26385890 0.89847623 536.50 7.54363318e-02 -3.70671158e+00 3.70747911e+00 -1.55044785 0.89787776 536.75 -2.09532722e-01 -3.65024453e+00 3.65625342e+00 -1.62813578 0.87050125 537.00 -1.07088541e+00 -2.99153096e+00 3.17742869e+00 -1.91455575 0.69426192 537.25 -1.58056972e+00 -2.32226645e+00 2.80911411e+00 -2.16839351 0.60591027 537.50 -1.37225992e+00 -5.65874668e-01 1.48435556e+00 -2.75047076 0.28786885 537.75 -7.46659795e-01 -5.79773588e-02 7.48907353e-01 -3.06409919 0.10299204 538.00 1.47858147e-01 6.82138021e-01 6.97978733e-01 1.35734146 0.09902343 538.25 6.53967058e-01 7.05900756e-01 9.62272721e-01 0.82356987 0.16402434 538.50 1.61010816e+00 3.49557928e-01 1.64761617e+00 0.21378455 0.40096126 538.75 2.03454324e+00 -1.29056124e-01 2.03863231e+00 -0.06334761 0.46153506 539.00 2.30305024e+00 -1.93468506e+00 3.00783089e+00 -0.69869110 0.61508213 539.25 1.92571185e+00 -2.30079422e+00 3.00033668e+00 -0.87391154 0.54531001 539.50 1.47164485e+00 -2.96458261e+00 3.30975658e+00 -1.11002582 0.55867645 539.75 1.21869273e+00 -3.33272013e+00 3.54855399e+00 -1.22022588 0.56299828 540.00 7.96679346e-01 -3.12517603e+00 3.22512375e+00 -1.32118962 0.62433442 540.25 5.46774932e-01 -3.23499539e+00 3.28087763e+00 -1.40336000 0.65229756 540.50 4.07273319e-02 -3.47854811e+00 3.47878652e+00 -1.55908872 0.72351874 540.75 -8.02494308e-01 -2.72827491e+00 2.84384970e+00 -1.85686818 0.57949078 541.00 -1.11608486e+00 -2.06333616e+00 2.34584772e+00 -2.06663601 0.55118174 541.25 -9.55920764e-01 -2.15822047e+00 2.36044490e+00 -1.98774763 0.61003987 541.50 -6.20334319e-01 -1.73801586e+00 1.84540342e+00 -1.91362347 0.55781065 541.75 -5.20863813e-01 -1.39113844e+00 1.48545120e+00 -1.92905447 0.45884320 542.00 -7.33654060e-01 -1.41015128e+00 1.58958325e+00 -2.05052514 0.48160437 542.25 -8.75658443e-02 -1.11745241e+00 1.12087808e+00 -1.64899855 0.32720349 542.50 1.72178305e-01 -1.11015446e+00 1.12342703e+00 -1.41692822 0.38168363 542.75 1.45173204e-01 -1.69101048e+00 1.69723060e+00 -1.48515634 0.48585986 543.00 2.81693177e-01 -2.33201807e+00 2.34896984e+00 -1.45058500 0.65630508 543.25 1.63364443e-01 -2.45475969e+00 2.46018965e+00 -1.50434424 0.63423726 543.50 2.01263080e-01 -2.42232343e+00 2.43067020e+00 -1.48789994 0.56720693 543.75 -1.03876553e+00 -3.04862777e+00 3.22073984e+00 -1.89919098 0.63767369 544.00 -1.55175330e+00 -3.09445009e+00 3.46172785e+00 -2.03561393 0.74821836 544.25 -1.65206426e+00 -2.54865139e+00 3.03725867e+00 -2.14591298 0.82689868 544.50 -1.71833622e+00 -2.38396791e+00 2.93870419e+00 -2.19533836 0.85920759 544.75 -1.75255870e+00 -1.94025303e+00 2.61458291e+00 -2.30541125 0.80796505 545.00 -1.70440328e+00 -1.88171731e+00 2.53886797e+00 -2.30679020 0.79389141 545.25 -1.76533863e+00 -1.78197845e+00 2.50835956e+00 -2.35150371 0.78571440 545.50 -1.82752000e+00 -1.62218858e+00 2.44362950e+00 -2.41564573 0.80019726 545.75 -1.76668386e+00 -1.59945690e+00 2.38315637e+00 -2.40583282 0.78413669 546.00 -2.00810151e+00 -1.58502032e+00 2.55827307e+00 -2.47340233 0.80432462 546.25 -2.29406770e+00 -1.33200024e+00 2.65272902e+00 -2.61553897 0.78768708 546.50 -2.42074414e+00 -1.15983373e+00 2.68425342e+00 -2.69478585 0.76175654 546.75 -2.52820912e+00 -9.88110685e-01 2.71444361e+00 -2.76901268 0.75366973 547.00 -2.56437911e+00 -4.84672660e-01 2.60977926e+00 -2.95479416 0.77249757 547.25 -2.28152310e+00 3.73825850e-01 2.31194581e+00 2.97918649 0.66087474 547.50 -2.18052465e+00 4.83377604e-01 2.23345957e+00 2.92344095 0.58241692 547.75 -2.27866013e+00 5.89385013e-01 2.35364965e+00 2.88848559 0.56782590 548.00 -2.15601973e+00 3.62061542e-01 2.18620897e+00 2.97521452 0.56891336 548.25 -2.14377399e+00 6.58468274e-01 2.24262065e+00 2.84358575 0.70317825 548.50 -2.11638119e+00 8.71832725e-01 2.28892150e+00 2.75083143 0.65145998 548.75 -2.03981428e+00 1.30901227e+00 2.42370696e+00 2.57105235 0.60796772 549.00 -2.24177995e+00 1.57338573e+00 2.73881726e+00 2.52962841 0.57140558 549.25 -2.33368985e+00 1.70680408e+00 2.89124342e+00 2.51011803 0.63221865 549.50 -1.97944046e+00 1.71743792e+00 2.62064449e+00 2.42694748 0.67825454 549.75 -2.13035175e+00 2.38269325e+00 3.19618924e+00 2.30033885 0.73923292 550.00 -1.94376090e+00 3.09847120e+00 3.65769466e+00 2.13106869 0.66668220 550.25 -2.25647094e+00 3.90166426e+00 4.50717706e+00 2.09513371 0.72975772 550.50 -2.12781823e+00 3.66725303e+00 4.23985320e+00 2.09654568 0.68353054 550.75 -1.74301009e+00 3.75517011e+00 4.13997424e+00 2.00536538 0.66659205 551.00 -1.66838103e+00 3.68603484e+00 4.04602868e+00 1.99582870 0.61651182 551.25 -1.16915244e+00 4.32837663e+00 4.48349882e+00 1.83461383 0.53064261 551.50 -1.14881510e-01 4.88748139e+00 4.88883136e+00 1.59429726 0.40960007 551.75 9.38156254e-01 6.39161038e+00 6.46009446e+00 1.42505766 0.50136226 552.00 1.77917462e+00 6.06987990e+00 6.32525923e+00 1.28566768 0.51998669 552.25 3.92438916e+00 5.84111945e+00 7.03700978e+00 0.97920994 0.67163361 552.50 6.39381376e+00 4.96499288e+00 8.09518429e+00 0.66026569 0.75628245 552.75 7.22624849e+00 4.20711877e+00 8.36172922e+00 0.52722811 0.84085297 553.00 6.67412478e+00 3.35927466e+00 7.47185839e+00 0.46630656 0.81566384 553.25 7.05266570e+00 1.70719703e+00 7.25634999e+00 0.23749573 0.81715742 553.50 7.32845116e+00 1.24011920e+00 7.43263695e+00 0.16763180 0.86102068 553.75 7.14528512e+00 1.07523692e+00 7.22573414e+00 0.14936132 0.83982177 554.00 6.24253261e+00 7.74603303e-01 6.29040727e+00 0.12345376 0.79127384 554.25 6.13252409e+00 3.63901863e-01 6.14331151e+00 0.05927015 0.81445710 554.50 5.75879290e+00 -3.33147209e-02 5.75888926e+00 -0.00578495 0.84660949 554.75 5.17571536e+00 -6.59868009e-01 5.21761011e+00 -0.12680898 0.88625204 555.00 4.77938319e+00 -1.14229850e+00 4.91399527e+00 -0.23460436 0.92149888 555.25 4.54279965e+00 -1.07068576e+00 4.66726865e+00 -0.23146435 0.88169182 555.50 4.10187718e+00 -9.58093906e-01 4.21228446e+00 -0.22946063 0.80585569 555.75 4.03725517e+00 -1.20555732e+00 4.21340691e+00 -0.29017938 0.82129399 556.00 4.32631165e+00 -1.35272502e+00 4.53286195e+00 -0.30304335 0.88652566 556.25 4.37860654e+00 -1.61277500e+00 4.66618028e+00 -0.35291079 0.90797627 556.50 4.20171894e+00 -2.03582568e+00 4.66894295e+00 -0.45118879 0.90497081 556.75 4.52997121e+00 -2.40013759e+00 5.12652900e+00 -0.48722981 0.89123772 557.00 3.65659304e+00 -2.79876619e+00 4.60475459e+00 -0.65328618 0.89204812 557.25 3.20078979e+00 -3.04265254e+00 4.41619630e+00 -0.76007504 0.90640409 557.50 2.59646175e+00 -2.84451654e+00 3.85134885e+00 -0.83095672 0.86499130 557.75 2.43417881e+00 -2.90197635e+00 3.78770289e+00 -0.87284027 0.82816020 558.00 2.08042969e+00 -2.67324383e+00 3.38739137e+00 -0.90946420 0.80852420 558.25 1.95433078e+00 -2.29518771e+00 3.01451413e+00 -0.86543753 0.76803937 558.50 1.84321744e+00 -1.80217402e+00 2.57784439e+00 -0.77413965 0.78312878 558.75 1.86245057e+00 -1.70539935e+00 2.52529386e+00 -0.74140811 0.80379661 559.00 1.79993710e+00 -1.67425696e+00 2.45823309e+00 -0.74923860 0.77039134 559.25 1.74654770e+00 -1.62288578e+00 2.38415334e+00 -0.74871353 0.78813458 559.50 1.69336932e+00 -1.66884360e+00 2.37750681e+00 -0.77810378 0.80984716 559.75 1.55272941e+00 -1.62698232e+00 2.24900869e+00 -0.80874601 0.79675154 560.00 1.60374290e+00 -1.38449048e+00 2.11868006e+00 -0.71215748 0.75895484 560.25 1.69558682e+00 -1.23823564e+00 2.09958143e+00 -0.63075366 0.77796737 560.50 1.94541484e+00 -1.32187058e+00 2.35201631e+00 -0.59682103 0.84380084 560.75 1.86902617e+00 -1.32995685e+00 2.29391457e+00 -0.61845387 0.82213770 561.00 1.84380695e+00 -1.35238039e+00 2.28660376e+00 -0.63283887 0.82594591 561.25 1.91388015e+00 -1.59593271e+00 2.49197481e+00 -0.69505660 0.86602069 561.50 1.97901739e+00 -1.74700984e+00 2.63980174e+00 -0.72321171 0.86671685 561.75 2.08705990e+00 -1.72433158e+00 2.70723815e+00 -0.69051441 0.84387659 562.00 2.05815624e+00 -1.88994649e+00 2.79426284e+00 -0.74281870 0.86786484 562.25 2.19520623e+00 -1.90056126e+00 2.90362936e+00 -0.71358299 0.88611855 562.50 2.34654499e+00 -1.86300906e+00 2.99617692e+00 -0.67103309 0.91528959 562.75 2.17922353e+00 -1.89373703e+00 2.88708419e+00 -0.71541950 0.88576982 563.00 2.25656783e+00 -2.19761101e+00 3.14985596e+00 -0.77216264 0.84108637 563.25 2.13518014e+00 -2.41111050e+00 3.22062852e+00 -0.84601732 0.79716872 563.50 2.14206163e+00 -2.48760458e+00 3.28277391e+00 -0.85989672 0.77616954 563.75 1.63198440e+00 -2.26290224e+00 2.78999993e+00 -0.94598943 0.66326113 564.00 1.17442381e+00 -2.71036975e+00 2.95387465e+00 -1.16191016 0.65266200 564.25 6.82034933e-01 -2.54716914e+00 2.63690013e+00 -1.30917166 0.53174841 564.50 5.42839229e-01 -2.17068287e+00 2.23752957e+00 -1.32574460 0.46846299 564.75 9.25058534e-01 -1.93063924e+00 2.14081788e+00 -1.12397047 0.43495203 565.00 1.13835980e+00 -2.43752555e+00 2.69024048e+00 -1.13388357 0.58052540 565.25 1.80253346e+00 -2.91777361e+00 3.42965446e+00 -1.01740794 0.55964918 565.50 1.98578935e+00 -3.50310819e+00 4.02680100e+00 -1.05509722 0.56139900 565.75 1.49282801e-01 -3.27239405e+00 3.27579734e+00 -1.52520910 0.38383110 566.00 -9.53943866e-01 -2.71572056e+00 2.87839314e+00 -1.90859971 0.35334560 566.25 -8.67522296e-01 -8.21387519e-01 1.19468506e+00 -2.38350400 0.10155130 566.50 -6.51581288e-01 -1.03505956e+00 1.22307256e+00 -2.13263287 0.12156375 566.75 2.50842430e-01 -1.45738834e+00 1.47881801e+00 -1.40034861 0.27951724 567.00 3.96724195e-01 -1.87551867e+00 1.91701862e+00 -1.36234139 0.48175171 567.25 1.74212640e-01 -2.33132788e+00 2.33782799e+00 -1.49620817 0.76240863 567.50 -2.49248053e-02 -2.41012141e+00 2.41025028e+00 -1.58113768 0.79430514 567.75 -3.81436799e-01 -2.76128640e+00 2.78750724e+00 -1.70806496 0.86019609 568.00 -5.69228280e-01 -2.75504002e+00 2.81323059e+00 -1.77454280 0.88404314 568.25 -1.13781383e+00 -2.54206549e+00 2.78508838e+00 -1.99164781 0.91738401 568.50 -1.32439956e+00 -2.36377028e+00 2.70950995e+00 -2.08150626 0.93438210 568.75 -1.54334471e+00 -1.84794196e+00 2.40765496e+00 -2.26661725 0.94152777 569.00 -1.56974964e+00 -1.57974205e+00 2.22703813e+00 -2.35302179 0.94489676 569.25 -1.45908250e+00 -1.16219364e+00 1.86537283e+00 -2.46897507 0.94574486 569.50 -1.37739862e+00 -9.43230441e-01 1.66940427e+00 -2.54114704 0.92233637 569.75 -1.14206940e+00 -7.36291848e-01 1.35884075e+00 -2.56895248 0.92349350 570.00 -1.12770738e+00 -6.84326319e-01 1.31910062e+00 -2.59616645 0.93204687 570.25 -1.06119581e+00 -5.77622254e-01 1.20821522e+00 -2.64312645 0.89525571 570.50 -9.22643441e-01 -3.90188018e-01 1.00175726e+00 -2.74150013 0.83964058 570.75 -8.05887599e-01 -1.01186981e-01 8.12215259e-01 -3.01668664 0.77359387 571.00 -5.45538798e-01 -1.21059622e-02 5.45673102e-01 -3.11940546 0.53966890 571.25 -1.34910503e-01 4.29106383e-02 1.41570359e-01 2.83364374 0.10391698 571.50 1.46700334e-02 5.62228635e-02 5.81052516e-02 1.31556066 0.01808879 571.75 2.59036713e-01 3.27000372e-02 2.61092533e-01 0.12557285 0.27473669 572.00 4.60076049e-01 -1.16580553e-01 4.74616684e-01 -0.24817054 0.47854716 572.25 7.68816212e-01 -2.62358563e-01 8.12348684e-01 -0.32885859 0.82702538 572.50 9.16835769e-01 -4.21508137e-01 1.00908718e+00 -0.43092598 0.85016002 572.75 9.85455086e-01 -6.29354669e-01 1.16927714e+00 -0.56835040 0.91068378 573.00 1.00051207e+00 -7.78902492e-01 1.26795643e+00 -0.66149540 0.89927529 573.25 1.05126177e+00 -1.04130008e+00 1.47968144e+00 -0.78063768 0.88795234 573.50 1.00492165e+00 -1.33426034e+00 1.67036468e+00 -0.92527104 0.88389150 573.75 8.86759649e-01 -1.51723229e+00 1.75736635e+00 -1.04188262 0.90848012 574.00 6.05060780e-01 -1.62905314e+00 1.73778959e+00 -1.21516913 0.91459745 574.25 3.90117138e-01 -1.75782616e+00 1.80059551e+00 -1.35240436 0.91661238 574.50 8.15086003e-02 -1.78136620e+00 1.78322999e+00 -1.52507199 0.89600360 574.75 -1.85268280e-01 -1.83050304e+00 1.83985480e+00 -1.67166451 0.92195539 575.00 -4.26704930e-01 -1.82005239e+00 1.86940306e+00 -1.80108370 0.89332164 575.25 -6.23225719e-01 -1.75457257e+00 1.86197078e+00 -1.91209691 0.92130284 575.50 -8.48311047e-01 -1.40584602e+00 1.64196061e+00 -2.11372436 0.89460714 575.75 -1.00130608e+00 -1.14339884e+00 1.51986011e+00 -2.29003835 0.88140315 576.00 -1.02998337e+00 -8.81861531e-01 1.35592975e+00 -2.43351590 0.83887737 576.25 -1.00435802e+00 -7.81589062e-01 1.27264155e+00 -2.48028792 0.84074190 576.50 -7.44336161e-01 -4.70486172e-01 8.80564341e-01 -2.57791237 0.76993645 576.75 -6.30044438e-01 -3.72043475e-01 7.31691425e-01 -2.60818510 0.67586630 577.00 -2.90066058e-01 -3.13118202e-01 4.26827045e-01 -2.31799566 0.33269984 577.25 -1.16017676e-01 -2.93341893e-01 3.15451371e-01 -1.94742021 0.23649215 577.50 1.89281190e-01 -4.69643034e-01 5.06351605e-01 -1.18767886 0.37057370 577.75 2.80789373e-01 -5.12235446e-01 5.84147091e-01 -1.06936329 0.48658489 578.00 2.32954073e-01 -7.01363053e-01 7.39038384e-01 -1.25011586 0.47810760 578.25 2.18885884e-01 -7.68531055e-01 7.99093869e-01 -1.29333224 0.47775285 578.50 3.38821092e-01 -1.10067712e+00 1.15164658e+00 -1.27217190 0.61953884 578.75 2.27538510e-01 -1.26691701e+00 1.28718782e+00 -1.39309070 0.69540638 579.00 7.85323221e-03 -1.27862620e+00 1.27865032e+00 -1.56465447 0.61537197 579.25 -6.25956992e-02 -1.36517283e+00 1.36660714e+00 -1.61661608 0.58993334 579.50 -4.82697955e-01 -1.43272633e+00 1.51185385e+00 -1.89576125 0.58946764 579.75 -8.08268036e-01 -1.38083282e+00 1.59999891e+00 -2.10037279 0.55536154 580.00 -1.13844732e+00 -1.26818230e+00 1.70421496e+00 -2.30233929 0.51913119 580.25 -1.37139393e+00 -9.48020434e-01 1.66717247e+00 -2.53674145 0.46794970 580.50 -1.77620776e+00 -7.33597258e-01 1.92173852e+00 -2.74991858 0.44296942 580.75 -1.57205419e+00 -3.26183656e-01 1.60553734e+00 -2.93700679 0.29548029 581.00 -9.86074864e-01 8.97294907e-01 1.33322233e+00 2.40329851 0.19413970 581.25 -3.53030567e-01 1.25210275e+00 1.30091963e+00 1.84561249 0.14175780 581.50 1.35678669e+00 1.49010185e+00 2.01526019e+00 0.83219235 0.40434411 581.75 2.00306032e+00 1.07379072e+00 2.27272461e+00 0.49208947 0.47383351 582.00 3.02829988e+00 1.68820983e-01 3.03300192e+00 0.05569013 0.60316103 582.25 3.08228759e+00 -1.14817117e+00 3.28919349e+00 -0.35658251 0.47282201 582.50 2.46748149e+00 -3.85132036e+00 4.57396255e+00 -1.00099764 0.52590862 582.75 -3.01774691e-01 -3.94917094e+00 3.96068417e+00 -1.64706281 0.52078683 583.00 -1.77608641e+00 -3.77662462e+00 4.17341304e+00 -2.01038986 0.65341526 583.25 -2.95274168e+00 -2.88427106e+00 4.12767525e+00 -2.36792437 0.67456088 583.50 -3.36883101e+00 -2.28615935e+00 4.07130777e+00 -2.54535960 0.69585319 583.75 -2.69908415e+00 -1.60510854e+00 3.14029118e+00 -2.60508940 0.58596984 584.00 -2.33975770e+00 -1.73550871e+00 2.91315234e+00 -2.50339430 0.56035326 584.25 -1.96564698e+00 -1.59525075e+00 2.53151990e+00 -2.45983942 0.35563138 584.50 -2.21000899e+00 -1.70148943e+00 2.78912281e+00 -2.48547572 0.32973355 584.75 -2.95514456e+00 -1.81200155e+00 3.46644328e+00 -2.59154666 0.43767168 585.00 -2.86121346e+00 -1.46315716e+00 3.21362278e+00 -2.66888537 0.36193326 585.25 -2.03178494e+00 -3.41252952e+00 3.97158756e+00 -2.10781901 0.42927765 585.50 -2.18998362e+00 -4.31699035e+00 4.84070593e+00 -2.04026215 0.53807634 585.75 -5.76100782e+00 -4.93745154e+00 7.58733411e+00 -2.43302194 0.70548006 586.00 -8.05352245e+00 -4.28694193e+00 9.12343658e+00 -2.65243515 0.74257812 586.25 -1.16655616e+01 -6.23160184e-01 1.16821940e+01 -3.08822459 0.70873364 586.50 -1.27598988e+01 3.09200802e+00 1.31291862e+01 2.90385301 0.72116774 586.75 -7.73375387e+00 8.35337926e+00 1.13837557e+01 2.31769669 0.70054166 587.00 -4.91658119e+00 8.81792405e+00 1.00959673e+01 2.07943037 0.77678534 587.25 -9.19918291e-01 8.83658544e+00 8.88433970e+00 1.67452605 0.78688610 587.50 9.92967770e-01 8.61102253e+00 8.66808480e+00 1.45598983 0.77604809 587.75 3.98452928e+00 6.32057535e+00 7.47168966e+00 1.00831892 0.69407615 588.00 4.29680627e+00 4.64190456e+00 6.32533177e+00 0.82398616 0.70055110 588.25 4.32927110e+00 1.10049131e+00 4.46695303e+00 0.24892564 0.57706620 588.50 4.22766217e+00 1.07584782e-01 4.22903084e+00 0.02544233 0.56273396 588.75 2.81901596e+00 -1.77316760e+00 3.33031144e+00 -0.56147222 0.49264539 589.00 2.35580506e+00 -2.13163651e+00 3.17705708e+00 -0.73548501 0.55897471 589.25 1.69211019e+00 -2.13554112e+00 2.72466012e+00 -0.90073338 0.43654168 589.50 1.23053029e+00 -3.33720841e+00 3.55684759e+00 -1.21753356 0.52861751 589.75 1.62970783e-01 -3.28489154e+00 3.28893173e+00 -1.52122475 0.48296068 590.00 -4.87736537e-01 -2.46461501e+00 2.51241200e+00 -1.76616764 0.42666465 590.25 -8.71669408e-01 -2.80437167e+00 2.93671722e+00 -1.87215468 0.47948928 590.50 -6.64124242e-01 -2.89776637e+00 2.97289605e+00 -1.79609041 0.49411945 590.75 -8.32703593e-01 -2.56353492e+00 2.69538616e+00 -1.88487112 0.53925223 591.00 -9.08514964e-01 -2.62185536e+00 2.77480179e+00 -1.90436404 0.52074839 591.25 -6.78122677e-01 -2.38012160e+00 2.47483922e+00 -1.84835311 0.45284600 591.50 -3.48902977e-01 -2.40033790e+00 2.42556288e+00 -1.71514118 0.46760369 591.75 5.40284964e-02 -2.59590928e+00 2.59647147e+00 -1.54998639 0.57316154 592.00 5.01055678e-01 -2.45190726e+00 2.50257987e+00 -1.36921830 0.55179635 592.25 8.59910978e-01 -2.41815925e+00 2.56650366e+00 -1.22913641 0.57705094 592.50 1.62117613e+00 -2.81137868e+00 3.24531387e+00 -1.04772435 0.63171723 592.75 2.31933077e+00 -3.32871800e+00 4.05705050e+00 -0.96224550 0.77816438 593.00 2.43388816e+00 -3.31509293e+00 4.11262115e+00 -0.93749454 0.78827996 593.25 2.26974929e+00 -4.07600586e+00 4.66536018e+00 -1.06270445 0.79386862 593.50 1.94481904e+00 -5.09491894e+00 5.45348697e+00 -1.20614950 0.84444369 593.75 1.92114229e+00 -5.80942341e+00 6.11883878e+00 -1.25142292 0.89111904 594.00 1.43116234e+00 -6.58047209e+00 6.73430313e+00 -1.35664496 0.91641627 594.25 9.42115000e-01 -7.03391372e+00 7.09672621e+00 -1.43764981 0.92378496 594.50 8.30787594e-01 -7.55400842e+00 7.59955598e+00 -1.46125686 0.91023373 594.75 7.52056967e-01 -7.61546912e+00 7.65251329e+00 -1.47236163 0.90726992 595.00 4.59929078e-01 -7.16218834e+00 7.17694062e+00 -1.50666810 0.91457097 595.25 2.87920719e-01 -6.93336548e+00 6.93934112e+00 -1.52929334 0.89379107 595.50 3.32806859e-01 -6.53023138e+00 6.53870647e+00 -1.51987636 0.85898388 595.75 9.25618974e-01 -6.35389164e+00 6.42095861e+00 -1.42613643 0.86404432 596.00 1.90922992e+00 -7.21446376e+00 7.46281758e+00 -1.31208775 0.87672458 596.25 3.03233133e+00 -7.94380564e+00 8.50288664e+00 -1.20614480 0.86810359 596.50 3.01647787e+00 -9.44689986e+00 9.91680673e+00 -1.26172054 0.86569869 596.75 3.58955979e+00 -1.01988600e+01 1.08121083e+01 -1.23237918 0.87733519 597.00 5.28665333e+00 -1.19494807e+01 1.30667055e+01 -1.15426630 0.85202029 597.25 4.81226993e+00 -1.36030594e+01 1.44291776e+01 -1.23077240 0.83767092 597.50 4.96512042e+00 -1.59906442e+01 1.67437488e+01 -1.26973311 0.79069927 597.75 5.08440533e+00 -1.67159472e+01 1.74720940e+01 -1.27552287 0.71305011 598.00 8.31870054e+00 -1.71750153e+01 1.90835513e+01 -1.11974778 0.44215392 598.25 5.42111449e+00 -1.45764719e+01 1.55519135e+01 -1.21473872 0.23926003 598.50 -1.01133346e+00 1.48777786e+00 1.79896590e+00 2.16780958 0.00275427 598.75 -6.47140067e+00 6.74443207e+00 9.34699901e+00 2.33553801 0.08737173 599.00 -1.08458161e+01 1.20527860e+01 1.62142338e+01 2.30353389 0.32825906 599.25 -8.49373468e+00 1.11041219e+01 1.39801664e+01 2.22377634 0.26782000 599.50 -5.88735225e+00 9.33790072e+00 1.10388997e+01 2.13332605 0.24536053 599.75 -3.37633545e+00 1.02020886e+01 1.07462670e+01 1.89039631 0.31009899 600.00 -3.82849473e-01 1.17714564e+01 1.17776806e+01 1.60330841 0.63278452 600.25 -6.15907624e-01 9.98145507e+00 1.00004394e+01 1.63242338 0.63759846 600.50 -1.37969398e+00 6.40060998e+00 6.54762274e+00 1.78310447 0.63878311 600.75 -1.16049624e+00 6.80330352e+00 6.90157158e+00 1.73974853 0.69214319 601.00 -1.11891107e+00 6.74077321e+00 6.83300706e+00 1.73528801 0.65943533 601.25 -1.29840034e+00 6.03041543e+00 6.16861035e+00 1.78286744 0.61587561 601.50 -1.04383187e+00 5.79174217e+00 5.88505415e+00 1.74910973 0.64814039 601.75 -4.19126047e-01 5.59551416e+00 5.61118930e+00 1.64556065 0.58509558 602.00 1.06366805e+00 4.78677363e+00 4.90352848e+00 1.35213921 0.58380760 602.25 1.65544296e+00 3.93337182e+00 4.26754089e+00 1.17242799 0.59614976 602.50 1.80491195e+00 2.33628238e+00 2.95227412e+00 0.91301417 0.50291894 602.75 1.99255972e+00 8.30142384e-01 2.15857143e+00 0.39475228 0.37429337 603.00 2.15596880e+00 -3.36308319e-01 2.18204142e+00 -0.15474236 0.45447312 603.25 1.22425099e+00 -1.02891077e+00 1.59920225e+00 -0.69891835 0.28617648 603.50 9.76217512e-01 -2.02237176e+00 2.24565985e+00 -1.12107677 0.55416718 603.75 7.18065864e-01 -2.56967556e+00 2.66811752e+00 -1.29830853 0.59899632 604.00 4.05767080e-01 -3.17789588e+00 3.20369616e+00 -1.44379931 0.64140268 604.25 5.07166913e-01 -3.13311409e+00 3.17389701e+00 -1.41031525 0.44981048 604.50 6.10417261e-01 -3.38191936e+00 3.43656628e+00 -1.39222462 0.44591544 604.75 6.45468067e-01 -3.19496627e+00 3.25951507e+00 -1.37145291 0.32932047 605.00 1.32291919e+00 -2.85451679e+00 3.14616930e+00 -1.13681575 0.23770189 605.25 2.12707491e-01 -7.19552596e-01 7.50333536e-01 -1.28337121 0.01306057 605.50 3.07893097e-01 -5.53098124e-01 6.33021084e-01 -1.06284667 0.00744095 605.75 -8.06005211e-01 1.51409415e+00 1.71526251e+00 2.05997603 0.06007286 606.00 -8.89827481e-01 2.78467699e+00 2.92339167e+00 1.88008579 0.17356973 606.25 -1.09898337e+00 3.75394132e+00 3.91150097e+00 1.85559273 0.45814365 606.50 -1.24312583e+00 3.75879692e+00 3.95902969e+00 1.89019700 0.52596031 606.75 -1.68750203e-01 3.94918037e+00 3.95278412e+00 1.61350079 0.57889926 607.00 -2.28562396e-01 3.70782768e+00 3.71486566e+00 1.63236163 0.68333363 607.25 2.34313925e-02 3.55949958e+00 3.55957670e+00 1.56421364 0.73634965 607.50 3.22229212e-01 3.52063346e+00 3.53534887e+00 1.47952470 0.72586944 607.75 6.30026306e-01 3.46146502e+00 3.51833387e+00 1.39075574 0.73974486 608.00 9.54553302e-01 3.51269959e+00 3.64008659e+00 1.30546017 0.76300147 608.25 1.28476999e+00 3.45567458e+00 3.68677647e+00 1.21484675 0.77891711 608.50 1.30122024e+00 3.52635880e+00 3.75877380e+00 1.21729781 0.80773717 608.75 9.53828744e-01 3.28162398e+00 3.41743255e+00 1.28793248 0.74813060 609.00 1.07076702e+00 3.30854513e+00 3.47750095e+00 1.25779787 0.70078960 609.25 1.53170711e+00 4.35422080e+00 4.61577355e+00 1.23254087 0.63701287 609.50 2.20783633e+00 4.38466919e+00 4.90916135e+00 1.10432437 0.61077900 609.75 3.82654177e+00 3.84258738e+00 5.42290510e+00 0.78749039 0.65052673 610.00 3.98737886e+00 3.37905308e+00 5.22658491e+00 0.70300433 0.65714255 610.25 4.43969115e+00 3.24136049e+00 5.49702423e+00 0.63063447 0.67675968 610.50 4.61470079e+00 2.92980477e+00 5.46618874e+00 0.56567614 0.66321644 610.75 4.91349808e+00 1.48980614e+00 5.13439243e+00 0.29439623 0.70948967 611.00 5.09006949e+00 1.32305245e+00 5.25920861e+00 0.25430078 0.79736135 611.25 4.29966670e+00 5.46290644e-01 4.33423202e+00 0.12637706 0.76519278 611.50 4.43934386e+00 2.43469731e-01 4.44601523e+00 0.05478874 0.70631447 611.75 4.41954834e+00 -4.68574055e-01 4.44431875e+00 -0.10562846 0.73344067 612.00 3.74712776e+00 -1.02328793e+00 3.88433838e+00 -0.26658586 0.75075566 612.25 3.20580287e+00 -1.48395056e+00 3.53260262e+00 -0.43352563 0.74382613 612.50 2.53961867e+00 -1.37666304e+00 2.88874784e+00 -0.49673818 0.68971256 612.75 1.45957048e+00 -1.38349560e+00 2.01107087e+00 -0.75864651 0.52660777 613.00 4.46965929e-01 -1.12328584e+00 1.20894566e+00 -1.19209354 0.25703284 613.25 -4.97396978e-01 -5.12349994e-01 7.14077216e-01 -2.34138690 0.16155461 613.50 -4.73595839e-01 8.05735598e-02 4.80400996e-01 2.97307471 0.04736761 613.75 -3.07269923e-01 5.66768207e-01 6.44702262e-01 2.06758798 0.04300900 614.00 8.01974221e-02 7.59192846e-01 7.63416927e-01 1.46555152 0.04653166 614.25 1.02167209e+00 1.18794495e+00 1.56685260e+00 0.86050623 0.17996289 614.50 1.04379693e+00 7.16997928e-01 1.26633253e+00 0.60188880 0.15384353 614.75 1.08765303e+00 -1.49991313e-01 1.09794650e+00 -0.13703929 0.17494180 615.00 6.00248132e-01 -4.54229773e-01 7.52743320e-01 -0.64779865 0.12397130 615.25 1.90064658e-01 -8.00209810e-01 8.22472075e-01 -1.33759899 0.21592909 615.50 -2.80413751e-01 -7.43860534e-01 7.94959349e-01 -1.93129376 0.32833426 615.75 -3.20738382e-01 -4.75448231e-01 5.73519075e-01 -2.16427260 0.20495332 616.00 -2.38939497e-01 -4.56294683e-01 5.15069822e-01 -2.05318579 0.20506448 616.25 -1.41184734e-01 -5.09762016e-01 5.28952212e-01 -1.84098573 0.26715016 616.50 -2.81782848e-01 -4.93075030e-01 5.67912457e-01 -2.08998171 0.36315145 616.75 -3.63351112e-01 -5.05949464e-01 6.22903597e-01 -2.19360449 0.45599760 617.00 -4.77926826e-01 -4.90226972e-01 6.84643363e-01 -2.34349043 0.54525345 617.25 -6.20985816e-01 -6.19238224e-01 8.76971699e-01 -2.35760358 0.67809009 617.50 -7.93885496e-01 -7.77740408e-01 1.11136597e+00 -2.36646699 0.81731350 617.75 -8.53634305e-01 -7.28888323e-01 1.12248373e+00 -2.43485912 0.83987164 618.00 -1.06284662e+00 -6.70947562e-01 1.25690635e+00 -2.57849433 0.79593253 618.25 -1.25375258e+00 -8.09167656e-01 1.49219564e+00 -2.56846038 0.85189526 618.50 -1.35689004e+00 -6.91624811e-01 1.52298899e+00 -2.67020468 0.89234126 618.75 -1.41426750e+00 -5.80744804e-01 1.52886137e+00 -2.75195370 0.90099360 619.00 -1.36551188e+00 -5.51460722e-01 1.47266141e+00 -2.75777251 0.80206716 619.25 -1.47827236e+00 -6.69104446e-01 1.62264905e+00 -2.71655712 0.83832216 619.50 -1.55074465e+00 -7.70848540e-01 1.73176685e+00 -2.68028150 0.84099354 619.75 -1.61583115e+00 -1.03650658e+00 1.91970211e+00 -2.57123759 0.84208683 620.00 -1.56741949e+00 -1.68855908e+00 2.30391746e+00 -2.31900636 0.87215326 620.25 -1.85654809e+00 -1.88262697e+00 2.64406035e+00 -2.34922010 0.85889977 620.50 -2.78426561e+00 -1.87968680e+00 3.35936861e+00 -2.54776711 0.90192957 620.75 -3.14807146e+00 -1.86115464e+00 3.65708224e+00 -2.60766539 0.91068229 621.00 -3.84299205e+00 -1.95240497e+00 4.31050729e+00 -2.67153142 0.93695158 621.25 -4.18537274e+00 -1.64801065e+00 4.49814229e+00 -2.76648163 0.93070444 621.50 -4.81485764e+00 -1.18461375e+00 4.95844369e+00 -2.90035113 0.93361014 621.75 -5.21208403e+00 -7.80992759e-01 5.27027225e+00 -2.99285655 0.92231567 622.00 -5.71202840e+00 -2.87451424e-01 5.71925666e+00 -3.09131119 0.95595766 622.25 -5.72341321e+00 -1.48187085e-01 5.72533128e+00 -3.11570705 0.94421047 622.50 -5.78314254e+00 6.20085922e-01 5.81629128e+00 3.03477774 0.90687626 622.75 -6.03257976e+00 1.10665889e+00 6.13324649e+00 2.96016287 0.91846768 623.00 -6.16356611e+00 1.75374378e+00 6.40821071e+00 2.86438459 0.91554407 623.25 -5.68373846e+00 2.40749527e+00 6.17259397e+00 2.74092876 0.86019038 623.50 -5.58601045e+00 3.80424357e+00 6.75838604e+00 2.54371166 0.87841721 623.75 -5.22723144e+00 4.00703121e+00 6.58636832e+00 2.48757173 0.87356790 624.00 -5.03910450e+00 3.90926228e+00 6.37768812e+00 2.48179226 0.86768239 624.25 -4.15369305e+00 4.33080201e+00 6.00075095e+00 2.33532310 0.82997874 624.50 -3.42835315e+00 4.78516886e+00 5.88654791e+00 2.19248007 0.86795244 624.75 -3.06040890e+00 4.28837929e+00 5.26842477e+00 2.19062582 0.84889325 625.00 -2.92985233e+00 4.20216832e+00 5.12271932e+00 2.17965673 0.81917325 625.25 -3.23010241e+00 4.21571940e+00 5.31091815e+00 2.22458779 0.83197831 625.50 -2.71839335e+00 4.30810851e+00 5.09406137e+00 2.13369478 0.78910642 625.75 -2.35041453e+00 4.79323864e+00 5.33850027e+00 2.02670258 0.82312840 626.00 -2.28837293e+00 5.35059183e+00 5.81940578e+00 1.97493979 0.89864494 626.25 -1.82124088e+00 5.21094570e+00 5.52004288e+00 1.90702827 0.89781384 626.50 -1.44388459e+00 4.86762854e+00 5.07726406e+00 1.85915851 0.89112339 626.75 -1.29509430e+00 4.85391489e+00 5.02371964e+00 1.83153662 0.89623716 627.00 -1.00890833e+00 4.82437536e+00 4.92874159e+00 1.77695248 0.88594771 627.25 -6.98291689e-01 4.76492374e+00 4.81581868e+00 1.71630888 0.90913000 627.50 -7.97649072e-01 4.75519213e+00 4.82162797e+00 1.73699183 0.91044367 627.75 -1.20387494e-01 4.46967600e+00 4.47129698e+00 1.59772409 0.88269892 628.00 1.31413678e-01 4.48664660e+00 4.48857074e+00 1.54151474 0.89634665 628.25 2.81348497e-01 4.10290609e+00 4.11254123e+00 1.50233053 0.88218537 628.50 4.12239327e-01 3.90799929e+00 3.92968189e+00 1.46569896 0.88244088 628.75 3.55070482e-01 3.51670704e+00 3.53458674e+00 1.47017059 0.86849295 629.00 1.98859454e-01 3.44192032e+00 3.44766016e+00 1.51308476 0.84361359 629.25 2.14170081e-01 2.77242835e+00 2.78068837e+00 1.49369945 0.77204179 629.50 9.06350338e-02 2.41898080e+00 2.42067817e+00 1.53334557 0.73718707 629.75 -2.24542251e-01 2.33029304e+00 2.34108626e+00 1.66685770 0.72260516 630.00 -2.09377625e-01 2.31978370e+00 2.32921347e+00 1.66080982 0.72229486 630.25 -2.12851683e-01 2.55555591e+00 2.56440478e+00 1.65389430 0.73673318 630.50 -2.61024690e-01 2.61464343e+00 2.62764042e+00 1.67029849 0.74391912 630.75 -2.90858594e-01 2.56666735e+00 2.58309504e+00 1.68363645 0.71219848 631.00 -2.14914577e-01 2.32786175e+00 2.33776145e+00 1.66285810 0.70066998 631.25 -3.24748750e-01 2.17157037e+00 2.19571848e+00 1.71924182 0.63214619 631.50 -4.52994160e-01 1.89373540e+00 1.94716138e+00 1.80559106 0.59325430 631.75 -4.98073094e-01 1.35924629e+00 1.44762815e+00 1.92203539 0.46282886 632.00 -4.96425781e-01 1.31881023e+00 1.40914831e+00 1.93081084 0.42995123 632.25 -8.15404508e-01 1.32338678e+00 1.55442500e+00 2.12300613 0.39449548 632.50 -1.22129996e+00 1.74215494e+00 2.12759899e+00 2.18221211 0.53644687 632.75 -1.39812512e+00 2.41650791e+00 2.79182097e+00 2.09531132 0.63403662 633.00 -1.54894736e+00 2.69893979e+00 3.11183449e+00 2.09181073 0.71180151 633.25 -1.21005709e+00 3.03672896e+00 3.26893881e+00 1.94998637 0.78433025 633.50 -1.19987340e+00 2.86387803e+00 3.10507545e+00 1.96754679 0.79284147 633.75 -1.34966874e+00 2.52555390e+00 2.86356914e+00 2.06158766 0.82496604 634.00 -1.67334227e+00 2.61259868e+00 3.10253867e+00 2.14045677 0.83529617 634.25 -1.99123013e+00 2.36985609e+00 3.09535383e+00 2.26959246 0.89526036 634.50 -2.18043560e+00 2.47664366e+00 3.29970654e+00 2.29267622 0.87099330 634.75 -2.82207021e+00 2.70923286e+00 3.91203565e+00 2.37659144 0.89522013 635.00 -3.03790995e+00 3.61695915e+00 4.72348286e+00 2.26940173 0.90173964 635.25 -3.33806074e+00 4.16481714e+00 5.33744801e+00 2.24644536 0.93221265 635.50 -3.07972136e+00 4.59526776e+00 5.53183237e+00 2.16123703 0.93085275 635.75 -2.55088532e+00 4.90811113e+00 5.53141670e+00 2.05010190 0.91768052 636.00 -1.97592931e+00 5.21702073e+00 5.57867385e+00 1.93284771 0.88807905 636.25 -1.70244003e+00 5.61072200e+00 5.86331846e+00 1.86539345 0.89571616 636.50 -1.31943857e+00 5.64681915e+00 5.79892100e+00 1.80033851 0.87408231 636.75 -1.23211820e+00 5.53605414e+00 5.67150868e+00 1.78978954 0.88796239 637.00 -1.56177153e+00 5.41109855e+00 5.63197282e+00 1.85178379 0.87966653 637.25 -1.74362411e+00 5.77306947e+00 6.03063480e+00 1.86411192 0.88395025 637.50 -1.93203223e+00 6.46713513e+00 6.74956186e+00 1.86110248 0.88243338 637.75 -1.69900711e+00 7.20425565e+00 7.40188656e+00 1.80239832 0.92345295 638.00 -1.54715021e+00 7.85312675e+00 8.00407855e+00 1.76531594 0.92342906 638.25 -1.59158850e+00 8.23468705e+00 8.38708678e+00 1.76172070 0.90372250 638.50 -5.29530515e-01 9.24408395e+00 9.25923813e+00 1.62801697 0.85821802 638.75 6.40787060e-01 1.02577552e+01 1.02777502e+01 1.50840885 0.88608778 639.00 3.25837763e+00 1.03115694e+01 1.08141337e+01 1.26473293 0.89478279 639.25 4.66775324e+00 9.73976263e+00 1.08005045e+01 1.12388843 0.90456822 639.50 5.50401434e+00 8.45284274e+00 1.00868590e+01 0.99361760 0.92506717 639.75 5.54526359e+00 7.47024262e+00 9.30346565e+00 0.93223261 0.91974280 640.00 5.72146971e+00 5.75942246e+00 8.11826106e+00 0.78870388 0.91443979 640.25 5.56288074e+00 5.29012050e+00 7.67665403e+00 0.76027121 0.90773738 640.50 4.53532305e+00 4.42526861e+00 6.33657300e+00 0.77311673 0.91533228 640.75 4.12373989e+00 4.25882605e+00 5.92813883e+00 0.80151190 0.91640307 641.00 3.27405323e+00 4.07583831e+00 5.22799029e+00 0.89405652 0.93063821 641.25 3.20727639e+00 4.09190623e+00 5.19906899e+00 0.90600569 0.93431242 641.50 2.60516054e+00 4.65191765e+00 5.33171635e+00 1.06029382 0.92371084 641.75 2.59443884e+00 5.01987079e+00 5.65068276e+00 1.09377256 0.89969151 642.00 3.01160105e+00 6.36132736e+00 7.03819768e+00 1.12863516 0.93620771 642.25 3.41945569e+00 6.25610286e+00 7.12962132e+00 1.07058324 0.89706450 642.50 4.59582463e+00 5.71142168e+00 7.33088956e+00 0.89321272 0.86352062 642.75 4.41977014e+00 5.48488673e+00 7.04402943e+00 0.89252344 0.85546774 643.00 3.20330687e+00 4.79541730e+00 5.76690575e+00 0.98187581 0.68543229 643.25 2.83268616e+00 4.94746231e+00 5.70100817e+00 1.05080271 0.70090538 643.50 2.15232903e+00 5.49609293e+00 5.90250436e+00 1.19754292 0.75835403 643.75 1.02172002e+00 5.30034207e+00 5.39791977e+00 1.38036715 0.64397579 644.00 -5.05040350e-01 5.52197922e+00 5.54502663e+00 1.66200260 0.68041397 644.25 -1.61113201e+00 4.81138866e+00 5.07397351e+00 1.89391846 0.59034657 644.50 -2.04100707e+00 4.40786362e+00 4.85746554e+00 2.00443936 0.57068692 644.75 -2.38056942e+00 3.45611843e+00 4.19664930e+00 2.17396492 0.52330735 645.00 -2.60541200e+00 2.22909568e+00 3.42885392e+00 2.43387749 0.49907708 645.25 -1.74379808e+00 1.22400854e+00 2.13049962e+00 2.52957857 0.29201111 645.50 -1.12426342e+00 7.38903822e-01 1.34534274e+00 2.56014902 0.14540731 645.75 -2.43188323e-01 -4.07521588e-01 4.74567598e-01 -2.10882236 0.02296296 646.00 7.81240144e-01 -5.30191174e-01 9.44160390e-01 -0.59625517 0.12145030 646.25 1.64015708e+00 -4.40315271e-01 1.69823225e+00 -0.26227518 0.35457312 646.50 2.18447698e+00 -4.71116545e-01 2.23470143e+00 -0.21241227 0.53759672 646.75 2.82096102e+00 -1.09467670e-01 2.82308418e+00 -0.03878564 0.67082678 647.00 3.11143901e+00 9.86225043e-02 3.11300162e+00 0.03168614 0.75443524 647.25 3.19880372e+00 2.87239146e-01 3.21167426e+00 0.08955561 0.74346951 647.50 3.18371448e+00 2.66985725e-01 3.19488956e+00 0.08366407 0.68187773 647.75 2.70008439e+00 6.21686398e-01 2.77073089e+00 0.22630299 0.49957731 648.00 2.70844259e+00 1.47191139e+00 3.08256133e+00 0.49780287 0.50440953 648.25 4.01238000e+00 2.59047453e+00 4.77595556e+00 0.57329028 0.54690283 648.50 5.47688150e+00 2.78699568e+00 6.14520755e+00 0.47071478 0.58563153 648.75 6.52537830e+00 1.61400608e+00 6.72202184e+00 0.24247632 0.44286020 649.00 5.71708637e+00 1.02469457e+00 5.80819038e+00 0.17735059 0.33327548 649.25 2.52971650e+00 -1.37666191e+00 2.88004576e+00 -0.49837634 0.07695791 649.50 -2.63841295e-01 -2.58613644e+00 2.59956033e+00 -1.67246598 0.05961453 649.75 -4.34364865e+00 -2.76824758e+00 5.15077453e+00 -2.57419065 0.29197316 650.00 -4.14089564e+00 -1.03788104e+00 4.26898275e+00 -2.89601015 0.31105205 650.25 -2.65369250e+00 1.47690381e+00 3.03699337e+00 2.63373708 0.39691192 650.50 -1.22197760e+00 1.79564621e+00 2.17199783e+00 2.16833017 0.31194006 650.75 1.41228186e+00 1.53775270e+00 2.08787534e+00 0.82790453 0.30305441 651.00 2.97152894e+00 6.85822732e-01 3.04964540e+00 0.22682610 0.45783933 651.25 2.98268847e+00 -1.22283985e+00 3.22362650e+00 -0.38907932 0.48599958 651.50 2.47358457e+00 -2.59830434e+00 3.58745119e+00 -0.80998361 0.48548535 651.75 1.91569192e+00 -2.57648634e+00 3.21063193e+00 -0.93144964 0.41558829 652.00 1.82599147e+00 -2.40277675e+00 3.01787690e+00 -0.92095723 0.51353987 652.25 1.13199925e+00 -3.19387560e+00 3.38854890e+00 -1.23018211 0.64720435 652.50 5.91072720e-01 -3.35899292e+00 3.41060118e+00 -1.39661231 0.66939827 652.75 -5.45754629e-01 -3.45549779e+00 3.49833005e+00 -1.72744048 0.74526420 653.00 -1.24091351e+00 -3.12660327e+00 3.36385409e+00 -1.94861767 0.76918308 653.25 -2.12870330e+00 -2.24346951e+00 3.09265795e+00 -2.32995128 0.76107874 653.50 -2.21202340e+00 -1.19640800e+00 2.51484385e+00 -2.64578923 0.70958208 653.75 -2.06302658e+00 5.12282231e-01 2.12567913e+00 2.89819969 0.64483355 654.00 -1.33401455e+00 1.55461965e+00 2.04852070e+00 2.27997241 0.61894540 654.25 -3.41194940e-01 2.30662523e+00 2.33172338e+00 1.71765098 0.78477670 654.50 3.83260345e-01 2.11060109e+00 2.14511665e+00 1.39116542 0.73443141 654.75 1.32362805e+00 1.50249101e+00 2.00236621e+00 0.84860312 0.70053381 655.00 1.66021938e+00 1.18362147e+00 2.03894291e+00 0.61935171 0.75465023 655.25 1.61211161e+00 5.15970382e-01 1.69266928e+00 0.30975621 0.80035990 655.50 1.43198738e+00 3.77573600e-01 1.48092866e+00 0.25780356 0.79690169 655.75 1.42618980e+00 1.31750359e-01 1.43226237e+00 0.09211781 0.80170539 656.00 1.30453153e+00 6.49503547e-02 1.30614741e+00 0.04974718 0.76776015 656.25 1.02049674e+00 2.88445299e-01 1.06047833e+00 0.27546607 0.62398116 656.50 9.16933215e-01 5.20574334e-01 1.05440228e+00 0.51635669 0.62053020 656.75 9.33028054e-01 7.37866486e-01 1.18953281e+00 0.66912436 0.66145409 657.00 1.18714836e+00 1.23332169e+00 1.71184217e+00 0.80447204 0.81148080 657.25 1.41227247e+00 1.65341521e+00 2.17446439e+00 0.86389515 0.89139344 657.50 2.04819765e+00 1.46445929e+00 2.51788693e+00 0.62072164 0.89311294 657.75 2.62276158e+00 1.22547494e+00 2.89493819e+00 0.43710281 0.94617086 658.00 2.63627999e+00 8.07981716e-01 2.75731874e+00 0.29739617 0.94453085 658.25 2.63838406e+00 3.26827997e-01 2.65854979e+00 0.12324647 0.94727781 658.50 2.21762098e+00 -1.35810989e-01 2.22177574e+00 -0.06116536 0.91530555 658.75 1.90248493e+00 -3.21865780e-01 1.92951976e+00 -0.16759481 0.91201712 659.00 1.39154783e+00 -1.11388282e-01 1.39599883e+00 -0.07987601 0.84092751 659.25 1.16118811e+00 1.07763887e-01 1.16617790e+00 0.09253978 0.84821069 659.50 1.03243708e+00 4.62087360e-01 1.13112822e+00 0.42083089 0.80909003 659.75 1.01599321e+00 6.61310274e-01 1.21225966e+00 0.57700785 0.82732297 660.00 1.02928195e+00 7.55702896e-01 1.27691354e+00 0.63331477 0.85326322 660.25 9.59464794e-01 7.67400329e-01 1.22860732e+00 0.67463194 0.84271480 660.50 7.18916812e-01 9.92244281e-01 1.22531224e+00 0.94379227 0.81836281 660.75 6.91521983e-01 1.22516151e+00 1.40684874e+00 1.05693944 0.86157343 661.00 7.75516493e-01 1.69371462e+00 1.86281911e+00 1.14140951 0.90980734 661.25 9.07643325e-01 1.94648404e+00 2.14770029e+00 1.13447123 0.93147423 661.50 1.12587668e+00 2.16759882e+00 2.44255665e+00 1.09174005 0.95427670 661.75 1.28258670e+00 2.24166382e+00 2.58265084e+00 1.05110024 0.95641752 662.00 1.64370869e+00 2.35834322e+00 2.87464102e+00 0.96210276 0.95866703 662.25 1.89679331e+00 2.35315965e+00 3.02244689e+00 0.89236977 0.94873839 662.50 2.21097214e+00 2.25936972e+00 3.16119429e+00 0.79622411 0.94979115 662.75 2.24287496e+00 2.23390094e+00 3.16556495e+00 0.78339359 0.94107226 663.00 2.06440015e+00 2.09773424e+00 2.94316783e+00 0.79340689 0.92487502 663.25 2.06636300e+00 2.19380053e+00 3.01373802e+00 0.81530301 0.93931052 663.50 2.07620116e+00 2.16336843e+00 2.99846198e+00 0.80595567 0.94925781 663.75 2.05429492e+00 2.21314214e+00 3.01962344e+00 0.82260408 0.94926884 664.00 2.02880255e+00 2.56007470e+00 3.26650000e+00 0.90065891 0.95286989 664.25 2.16578619e+00 2.59689885e+00 3.38149574e+00 0.87567097 0.92970156 664.50 2.59528156e+00 2.59384871e+00 3.66926935e+00 0.78512204 0.88918435 664.75 3.02940906e+00 2.56607869e+00 3.97014850e+00 0.70278235 0.84889485 665.00 3.55847554e+00 2.27973989e+00 4.22610484e+00 0.56977468 0.79130890 665.25 3.93950006e+00 1.34245750e+00 4.16195301e+00 0.32842721 0.69294174 665.50 3.90862803e+00 -4.77147839e-02 3.90891926e+00 -0.01220695 0.78733367 665.75 2.99379381e+00 -4.07525427e-01 3.02140337e+00 -0.13529187 0.64790115 666.00 2.31047692e+00 -5.76755698e-01 2.38137581e+00 -0.24462687 0.62991534 666.25 2.22579200e+00 -4.41592377e-01 2.26917471e+00 -0.19585457 0.71827030 666.50 2.25599472e+00 -3.20326102e-01 2.27862260e+00 -0.14104603 0.79112107 666.75 2.30117206e+00 -2.22708896e-01 2.31192390e+00 -0.09648016 0.78660791 667.00 2.19752454e+00 -3.21556926e-01 2.22092615e+00 -0.14529574 0.79447521 667.25 2.11896490e+00 -4.06734533e-01 2.15764807e+00 -0.18964297 0.80778358 667.50 2.07148279e+00 -5.43046578e-01 2.14148092e+00 -0.25638419 0.84641771 667.75 1.87631795e+00 -6.50357358e-01 1.98583326e+00 -0.33365482 0.87239720 668.00 1.60207617e+00 -7.43120923e-01 1.76603419e+00 -0.43431063 0.84074332 668.25 1.27774726e+00 -6.07973321e-01 1.41501577e+00 -0.44411438 0.75419342 668.50 9.71948910e-01 -3.88709340e-01 1.04679493e+00 -0.38044409 0.69098719 668.75 7.84813155e-01 -7.57068280e-02 7.88456221e-01 -0.09616722 0.50978603 669.00 6.33488763e-01 1.04769336e-01 6.42093940e-01 0.16390108 0.45273860 669.25 9.75351017e-01 3.65886352e-01 1.04172090e+00 0.35888727 0.71029672 669.50 1.05048120e+00 5.02067881e-01 1.16429502e+00 0.44584507 0.81020606 669.75 1.26858602e+00 4.34548094e-01 1.34094837e+00 0.33001823 0.81073110 670.00 1.41804359e+00 3.82277293e-01 1.46866727e+00 0.26332106 0.86770411 670.25 1.53984927e+00 6.49338068e-02 1.54121776e+00 0.04214397 0.82184071 670.50 1.44306413e+00 -8.80402755e-02 1.44574727e+00 -0.06093373 0.76939324 670.75 1.39428297e+00 -2.44426470e-01 1.41554559e+00 -0.17354277 0.76011265 671.00 1.28313337e+00 -3.10553025e-01 1.32017969e+00 -0.23746078 0.76794523 671.25 1.13679957e+00 -5.50270028e-01 1.26297679e+00 -0.45080795 0.65861634 671.50 1.14251408e+00 -6.75405835e-01 1.32721945e+00 -0.53389233 0.63495194 671.75 1.09272015e+00 -1.26731917e+00 1.67336045e+00 -0.85924503 0.77572205 672.00 9.29357150e-01 -1.34932421e+00 1.63840793e+00 -0.96765559 0.75376908 672.25 2.76872731e-01 -1.50401313e+00 1.52928546e+00 -1.38874526 0.63315028 672.50 -2.70554858e-01 -1.61710071e+00 1.63957758e+00 -1.73656952 0.66025971 672.75 -1.08573109e+00 -1.53168650e+00 1.87746519e+00 -2.18743511 0.69051388 673.00 -1.49539090e+00 -1.26915314e+00 1.96136270e+00 -2.43784801 0.68812290 673.25 -1.87705858e+00 -3.09623965e-01 1.90242369e+00 -2.97811307 0.65715687 673.50 -1.97417467e+00 2.93215348e-01 1.99583087e+00 2.99414504 0.60036629 673.75 -1.62989412e+00 1.01817733e+00 1.92178041e+00 2.58321683 0.61171183 674.00 -1.70144820e+00 1.14722256e+00 2.05208323e+00 2.54834988 0.62710693 674.25 -2.19097369e+00 1.59583229e+00 2.71054356e+00 2.51208122 0.68254367 674.50 -2.44526873e+00 1.93886479e+00 3.12066273e+00 2.47119318 0.60717663 674.75 -1.29457615e+00 2.65722056e+00 2.95579913e+00 2.02414500 0.40012632 675.00 -7.62398395e-01 4.10712715e+00 4.17728917e+00 1.75433538 0.53777641 675.25 -1.51983579e-01 5.60265730e+00 5.60471836e+00 1.59791673 0.80507480 675.50 1.31881284e+00 5.38909779e+00 5.54812061e+00 1.33079447 0.83593396 675.75 2.46479960e+00 4.65230069e+00 5.26489684e+00 1.08359211 0.91749788 676.00 3.28311724e+00 4.08755155e+00 5.24279853e+00 0.89410783 0.92742382 676.25 4.04037117e+00 3.56039034e+00 5.38525566e+00 0.72233286 0.93208633 676.50 4.13702939e+00 2.98544193e+00 5.10175222e+00 0.62510167 0.94476622 676.75 4.37283522e+00 2.57382991e+00 5.07408004e+00 0.53199143 0.96014183 677.00 4.65289275e+00 2.27252810e+00 5.17820383e+00 0.45433421 0.96022175 677.25 4.84621203e+00 1.90825254e+00 5.20837775e+00 0.37511696 0.97034310 677.50 5.19209074e+00 1.45782863e+00 5.39287220e+00 0.27373067 0.95780013 677.75 5.66350894e+00 9.16878794e-01 5.73724674e+00 0.16049983 0.96092792 678.00 5.98901314e+00 -1.29331543e-01 5.99040943e+00 -0.02159144 0.95084894 678.25 6.06069862e+00 -8.19854174e-01 6.11589965e+00 -0.13445769 0.96542929 678.50 5.64242553e+00 -1.95755212e+00 5.97235097e+00 -0.33394126 0.95092497 678.75 5.40559630e+00 -2.64018822e+00 6.01590103e+00 -0.45433881 0.97148595 679.00 4.75444403e+00 -3.35000911e+00 5.81612406e+00 -0.61381046 0.96096680 679.25 4.28084110e+00 -3.73254040e+00 5.67956498e+00 -0.71708151 0.97451903 679.50 3.60923081e+00 -4.03080666e+00 5.41054058e+00 -0.84052208 0.96766437 679.75 2.96170604e+00 -4.10919810e+00 5.06529482e+00 -0.94627927 0.96421454 680.00 2.23715412e+00 -4.11276492e+00 4.68184727e+00 -1.07260696 0.93800356 680.25 1.69431523e+00 -3.97686453e+00 4.32274862e+00 -1.16804260 0.93335843 680.50 1.24921439e+00 -3.42923962e+00 3.64968779e+00 -1.22145415 0.90095110 680.75 1.11018727e+00 -3.17783753e+00 3.36617990e+00 -1.23469796 0.90155333 681.00 1.08165084e+00 -2.95767230e+00 3.14925292e+00 -1.22019494 0.90235577 681.25 9.71208101e-01 -2.87323195e+00 3.03293702e+00 -1.24483427 0.89693580 681.50 7.52127554e-01 -2.35366430e+00 2.47091713e+00 -1.26149619 0.79481751 681.75 7.07807929e-01 -2.03064845e+00 2.15047092e+00 -1.23540269 0.76587412 682.00 4.69799674e-01 -1.24591404e+00 1.33154554e+00 -1.21021008 0.61863385 682.25 4.42096292e-01 -1.03805016e+00 1.12827180e+00 -1.16817118 0.45942610 682.50 8.62398489e-01 -3.28694776e-01 9.22914627e-01 -0.36414301 0.27819940 682.75 9.47508044e-01 9.61409717e-02 9.52373131e-01 0.10112110 0.29417637 683.00 1.47161671e+00 5.57873083e-01 1.57381006e+00 0.36235035 0.48392448 683.25 1.91924581e+00 1.02729254e+00 2.17688641e+00 0.49145492 0.64213114 683.50 3.18342826e+00 1.42875057e+00 3.48934717e+00 0.42186287 0.78732618 683.75 3.96060921e+00 1.37006637e+00 4.19088382e+00 0.33303826 0.82862296 684.00 5.00544776e+00 1.56049441e+00 5.24305732e+00 0.30220984 0.86937214 684.25 5.86708574e+00 1.38316090e+00 6.02792080e+00 0.23152185 0.84356682 684.50 7.40022182e+00 1.10849461e-01 7.40105199e+00 0.01497809 0.89638271 684.75 7.80596205e+00 -4.10467355e-01 7.81674657e+00 -0.05253544 0.85558773 685.00 8.40859626e+00 -2.78533904e+00 8.85791198e+00 -0.31987348 0.80949812 685.25 7.60016364e+00 -4.67388543e+00 8.92231430e+00 -0.55135542 0.78433914 685.50 7.00860593e+00 -6.99580151e+00 9.90261560e+00 -0.78448385 0.81394455 685.75 5.58479008e+00 -7.72977567e+00 9.53621058e+00 -0.94512645 0.79453680 686.00 2.37233852e+00 -8.63740616e+00 8.95727499e+00 -1.30274747 0.78269249 686.25 -3.09360096e-01 -8.20097942e+00 8.20681224e+00 -1.60850078 0.72067448 686.50 -3.90247779e+00 -7.32848719e+00 8.30277408e+00 -2.06011084 0.76113210 686.75 -5.51082693e+00 -4.95550857e+00 7.41122653e+00 -2.40920236 0.64221683 687.00 -6.80722644e+00 -2.86075815e-01 6.81323501e+00 -3.09959206 0.66443048 687.25 -6.88106816e+00 2.64262352e+00 7.37106220e+00 2.77491786 0.61639503 687.50 -7.74666287e+00 6.56185988e+00 1.01522801e+01 2.43881002 0.73657493 687.75 -5.59554490e+00 1.01063399e+01 1.15519795e+01 2.07645038 0.72965616 688.00 -3.78324028e+00 1.36119806e+01 1.41279483e+01 1.84188875 0.87212711 688.25 -1.99092319e+00 1.66446361e+01 1.67632839e+01 1.68984422 0.81250645 688.50 -3.83104888e-01 2.19112580e+01 2.19146069e+01 1.58827893 0.83965004 688.75 3.63218179e+00 2.48787810e+01 2.51425236e+01 1.42582537 0.75019215 689.00 1.08199147e+01 2.87837838e+01 3.07502319e+01 1.21123410 0.77528315 689.25 2.27428810e+01 3.25351297e+01 3.96960111e+01 0.96072478 0.72813821 689.50 3.36396834e+01 2.90613767e+01 4.44543801e+01 0.71250951 0.67705314 689.75 4.16788402e+01 1.07044128e+01 4.30315021e+01 0.25139731 0.59625142 690.00 4.50727750e+01 9.93916431e-01 4.50837323e+01 0.02204780 0.59145621 690.25 1.69697032e+01 -1.97615185e+01 2.60478107e+01 -0.86125891 0.30152713 690.50 8.91964309e+00 -2.27951662e+01 2.44781460e+01 -1.19781639 0.48893293 690.75 9.04892032e+00 -1.23481086e+01 1.53087800e+01 -0.93838247 0.61618234 691.00 1.03254860e+01 -9.28499169e+00 1.38862065e+01 -0.73238979 0.71466967 691.25 1.14427749e+01 -6.64021594e+00 1.32298740e+01 -0.52580653 0.73369264 691.50 1.26815487e+01 -4.55951066e+00 1.34763057e+01 -0.34514736 0.73653477 691.75 1.51728472e+01 -1.11738365e+00 1.52139357e+01 -0.07351094 0.89741084 692.00 1.62014636e+01 -3.60123475e-01 1.62054655e+01 -0.02222418 0.93004826 692.25 1.61589527e+01 1.40989927e+00 1.62203442e+01 0.08703149 0.87074065 692.50 1.65398228e+01 2.15595571e+00 1.66797447e+01 0.12961857 0.86548932 692.75 1.72705594e+01 2.83340456e+00 1.75014401e+01 0.16261120 0.86317927 693.00 1.97009266e+01 4.08930312e+00 2.01208576e+01 0.20466281 0.84422117 693.25 2.32542362e+01 4.77148829e+00 2.37387153e+01 0.20237893 0.79474520 693.50 2.34731000e+01 7.83776466e+00 2.47470600e+01 0.32226417 0.74640945 693.75 2.53026784e+01 9.44461532e+00 2.70078932e+01 0.35724909 0.67718551 694.00 2.78985416e+01 5.92843527e+00 2.85214826e+01 0.20938523 0.59283127 694.25 3.44297335e+01 5.56353815e-01 3.44342283e+01 0.01615770 0.59793410 694.50 3.20566382e+01 -4.00359584e+00 3.23056780e+01 -0.12424798 0.56684667 694.75 2.71820554e+01 -1.56052027e+01 3.13430453e+01 -0.52115722 0.47759227 695.00 2.60412155e+01 -1.63442112e+01 3.07453760e+01 -0.56048730 0.48840526 695.25 2.32358797e+01 -1.99671767e+01 3.06364856e+01 -0.70988297 0.50455151 695.50 2.04306092e+01 -1.97846538e+01 2.84401533e+01 -0.76933710 0.48400363 695.75 1.30341405e+01 -1.94218064e+01 2.33900702e+01 -0.97972487 0.62433085 696.00 1.24037967e+01 -1.75520120e+01 2.14924940e+01 -0.95559585 0.65809091 696.25 1.51694907e+01 -1.54048331e+01 2.16199521e+01 -0.79309540 0.71608028 696.50 1.55568358e+01 -1.13450661e+01 1.92542376e+01 -0.63009854 0.71702133 696.75 1.45605798e+01 -7.39640539e+00 1.63314818e+01 -0.47000696 0.82168254 697.00 1.51969096e+01 -3.71555944e+00 1.56445340e+01 -0.23979026 0.79630443 697.25 1.99290710e+01 -1.79596940e-01 1.99298802e+01 -0.00901156 0.83800174 697.50 2.32226394e+01 -7.83129776e-01 2.32358402e+01 -0.03370991 0.86184351 697.75 2.59232435e+01 -2.19882961e+00 2.60163296e+01 -0.08461823 0.86826411 698.00 2.70892271e+01 -3.74324894e+00 2.73466294e+01 -0.13731264 0.79358792 698.25 2.99814725e+01 -6.47546519e+00 3.06727948e+01 -0.21271480 0.78925021 698.50 2.86131325e+01 -9.86317597e+00 3.02653861e+01 -0.33195259 0.76288771 698.75 2.40805806e+01 -1.37488451e+01 2.77291382e+01 -0.51878645 0.77674856 699.00 1.67847154e+01 -8.01018049e+00 1.85981091e+01 -0.44526677 0.60565130 699.25 1.12358549e+01 -3.84340199e+00 1.18750232e+01 -0.32958910 0.41330321 699.50 1.43060545e+01 3.16972687e+00 1.46529984e+01 0.21804296 0.56581410 699.75 1.66775376e+01 7.41145853e+00 1.82502048e+01 0.41818525 0.76747452 700.00 2.06463695e+01 8.26502589e+00 2.22392272e+01 0.38077683 0.83031408 700.25 2.41442229e+01 9.22395465e+00 2.58461764e+01 0.36492463 0.88992676 700.50 2.61832082e+01 1.04422035e+01 2.81886503e+01 0.37948267 0.86557324 700.75 2.72659022e+01 1.11024684e+01 2.94396710e+01 0.38669131 0.83804942 701.00 2.93012263e+01 1.16467500e+01 3.15310744e+01 0.37833498 0.80143728 701.25 3.21064255e+01 1.15558919e+01 3.41227372e+01 0.34548882 0.83438834 701.50 3.62255951e+01 9.05574592e+00 3.73403304e+01 0.24496170 0.86990741 701.75 3.81812326e+01 6.06359070e+00 3.86597161e+01 0.15749550 0.88132023 702.00 3.92463036e+01 2.89141450e+00 3.93526699e+01 0.07354069 0.87282503 702.25 3.91183723e+01 3.50222533e-01 3.91199400e+01 0.00895265 0.87499690 702.50 3.90585926e+01 -4.96295895e+00 3.93726379e+01 -0.12638717 0.89496945 702.75 3.89720081e+01 -6.98365686e+00 3.95927882e+01 -0.17731478 0.90536051 703.00 3.73732319e+01 -9.38462226e+00 3.85334867e+01 -0.24601882 0.87012494 703.25 3.48869869e+01 -1.08193019e+01 3.65261433e+01 -0.30071906 0.85258836 703.50 2.76034699e+01 -1.63386791e+01 3.20765333e+01 -0.53444730 0.83987528 703.75 2.53704793e+01 -1.81504612e+01 3.11945582e+01 -0.62099789 0.86005090 704.00 2.19830531e+01 -1.87433789e+01 2.88889058e+01 -0.70601810 0.88274912 704.25 1.92642240e+01 -1.77408374e+01 2.61886929e+01 -0.74425442 0.86684224 704.50 1.47001706e+01 -1.45192041e+01 2.06616142e+01 -0.77920487 0.83984406 704.75 1.33276471e+01 -1.21512788e+01 1.80355137e+01 -0.73926068 0.83342097 705.00 1.19576984e+01 -9.54097147e+00 1.52976040e+01 -0.67345525 0.87038885 705.25 1.17378673e+01 -7.84879478e+00 1.41202375e+01 -0.58939031 0.84131884 705.50 1.08349848e+01 -5.03722536e+00 1.19486625e+01 -0.43517855 0.82565122 705.75 1.04653505e+01 -4.42307343e+00 1.13616521e+01 -0.39986982 0.84458448 706.00 1.09569835e+01 -2.97684381e+00 1.13541660e+01 -0.26528132 0.91266611 706.25 1.13275215e+01 -2.11832137e+00 1.15238895e+01 -0.18487127 0.91825788 706.50 1.15284095e+01 -1.37817483e+00 1.16104949e+01 -0.11898131 0.93823997 706.75 1.15743206e+01 -7.29075060e-01 1.15972604e+01 -0.06290763 0.93174383 707.00 1.21505027e+01 -8.35181221e-01 1.21791726e+01 -0.06862840 0.95388705 707.25 1.15762957e+01 -1.24163106e+00 1.16426917e+01 -0.10684786 0.93715799 707.50 1.10120310e+01 -1.70939754e+00 1.11439161e+01 -0.15400089 0.95619418 707.75 1.10009302e+01 -2.00834939e+00 1.11827515e+01 -0.18057321 0.94671279 708.00 1.12288078e+01 -2.39471931e+00 1.14813242e+01 -0.21011788 0.96824918 708.25 1.10211694e+01 -2.67698764e+00 1.13416242e+01 -0.23828057 0.95842903 708.50 1.06703987e+01 -3.00200614e+00 1.10846493e+01 -0.27425052 0.96034826 708.75 9.62836640e+00 -3.66462000e+00 1.03021784e+01 -0.36367698 0.95000633 709.00 9.34031674e+00 -3.67937476e+00 1.00388902e+01 -0.37525748 0.95964869 709.25 8.58881570e+00 -4.10457948e+00 9.51920836e+00 -0.44581034 0.95436637 709.50 7.47247968e+00 -4.26156579e+00 8.60226107e+00 -0.51829601 0.94964289 709.75 6.22348361e+00 -4.02895042e+00 7.41378377e+00 -0.57453024 0.91980492 710.00 5.63667987e+00 -3.92422244e+00 6.86816436e+00 -0.60816700 0.94136375 710.25 4.94567926e+00 -3.23675657e+00 5.91069678e+00 -0.57950519 0.93385249 710.50 4.62267264e+00 -2.89402247e+00 5.45384895e+00 -0.55935375 0.94888333 710.75 4.05226201e+00 -2.49576440e+00 4.75916667e+00 -0.55202446 0.93498574 711.00 3.80424187e+00 -2.35750925e+00 4.47550065e+00 -0.55478290 0.95102463 711.25 3.59090683e+00 -1.98943873e+00 4.10517701e+00 -0.50592531 0.95741269 711.50 3.43776381e+00 -1.93675778e+00 3.94578898e+00 -0.51305558 0.96431798 711.75 3.09941977e+00 -1.82864685e+00 3.59865978e+00 -0.53303152 0.95692425 712.00 2.91972982e+00 -1.86916901e+00 3.46678742e+00 -0.56944486 0.95483184 712.25 2.46920455e+00 -1.72191306e+00 3.01030824e+00 -0.60894884 0.93905036 712.50 2.22909067e+00 -1.66046852e+00 2.77956848e+00 -0.64023456 0.93646057 712.75 1.90053504e+00 -1.44851769e+00 2.38961021e+00 -0.65124016 0.94435897 713.00 1.69633194e+00 -1.39760102e+00 2.19791507e+00 -0.68914276 0.93993771 713.25 1.16794070e+00 -1.30742777e+00 1.75312659e+00 -0.84168866 0.87207763 713.50 9.95740294e-01 -1.16387861e+00 1.53170237e+00 -0.86309698 0.83650346 713.75 6.42666644e-01 -9.40250798e-01 1.13889946e+00 -0.97122645 0.85435642 714.00 5.23896817e-01 -8.95266365e-01 1.03728961e+00 -1.04134113 0.84906382 714.25 2.40724619e-01 -6.54964107e-01 6.97801063e-01 -1.21858311 0.74847862 714.50 1.11139532e-01 -5.09852117e-01 5.21824852e-01 -1.35616990 0.58875291 714.75 -1.98576119e-01 -2.57828198e-01 3.25434870e-01 -2.22709290 0.39448377 715.00 -2.91920054e-01 -1.50200994e-01 3.28295075e-01 -2.66639044 0.40611437 715.25 -3.83484835e-01 4.62513109e-02 3.86263903e-01 3.02156447 0.54119827 715.50 -4.41508622e-01 1.97958468e-01 4.83856815e-01 2.72009648 0.65404262 715.75 -5.00557622e-01 3.56984595e-01 6.14813740e-01 2.52207980 0.80658305 716.00 -5.19462168e-01 4.43119907e-01 6.82785614e-01 2.43533870 0.82978487 716.25 -5.06844604e-01 5.27767842e-01 7.31731062e-01 2.33597399 0.84402689 716.50 -6.04274505e-01 5.76435669e-01 8.35120206e-01 2.37976817 0.84584427 716.75 -6.97564433e-01 6.40971400e-01 9.47333349e-01 2.39844913 0.93710635 717.00 -7.27555719e-01 6.88984420e-01 1.00201639e+00 2.38341699 0.93708443 717.25 -7.68090277e-01 8.20788262e-01 1.12412457e+00 2.32303986 0.95184491 717.50 -7.35123863e-01 9.05717408e-01 1.16650380e+00 2.25259956 0.93841852 717.75 -6.89931368e-01 9.62998854e-01 1.18464007e+00 2.19247117 0.95262740 718.00 -6.62617977e-01 9.19432510e-01 1.13332199e+00 2.19526805 0.92854628 718.25 -6.00175560e-01 9.02782883e-01 1.08407917e+00 2.15750973 0.91259190 718.50 -5.40115204e-01 8.83129168e-01 1.03520122e+00 2.11969617 0.87485017 718.75 -4.87004752e-01 8.13619512e-01 9.48235381e-01 2.11016054 0.84349486 719.00 -5.06868362e-01 7.02006152e-01 8.65868451e-01 2.19615396 0.74963372 719.25 -6.26195196e-01 4.92740980e-01 7.96814970e-01 2.47490257 0.78883974 719.50 -7.60737874e-01 2.94775377e-01 8.15852092e-01 2.77192042 0.83455487 719.75 -8.46029298e-01 2.00524397e-01 8.69468577e-01 2.90886891 0.83433972 720.00 -9.86952939e-01 1.20178781e-01 9.94242950e-01 3.02042169 0.84093459 720.25 -1.21114282e+00 6.92510031e-02 1.21312103e+00 3.08447661 0.85315549 720.50 -1.58920648e+00 6.26166374e-02 1.59043959e+00 3.10221183 0.85434927 720.75 -1.90196712e+00 1.13947908e-01 1.90537740e+00 3.08175362 0.84843599 721.00 -2.23146630e+00 6.63549342e-01 2.32803342e+00 2.85255942 0.85771734 721.25 -2.35828786e+00 1.16009436e+00 2.62818199e+00 2.68442807 0.88422468 721.50 -1.98051169e+00 1.49893400e+00 2.48379341e+00 2.49372716 0.91235148 721.75 -1.77117214e+00 1.49713949e+00 2.31915446e+00 2.43984416 0.91421213 722.00 -1.15533746e+00 1.48495882e+00 1.88146415e+00 2.23199451 0.89052544 722.25 -9.96633144e-01 1.41656965e+00 1.73203556e+00 2.18390350 0.92112768 722.50 -8.37931790e-01 1.16087391e+00 1.43169757e+00 2.19601119 0.89893678 722.75 -7.95978413e-01 1.11347212e+00 1.36872269e+00 2.19142701 0.89463777 723.00 -8.36079862e-01 7.66185893e-01 1.13405042e+00 2.39978881 0.81679316 723.25 -8.34823356e-01 5.89612203e-01 1.02204334e+00 2.52666981 0.79688219 723.50 -8.76758233e-01 3.81462495e-01 9.56147810e-01 2.73121281 0.75756551 723.75 -9.77203195e-01 2.64301421e-01 1.01231484e+00 2.87744541 0.76645349 724.00 -1.15622694e+00 5.64630923e-02 1.15760477e+00 3.09279750 0.75997357 724.25 -1.26439218e+00 5.11424928e-03 1.26440252e+00 3.13754785 0.76688823 724.50 -1.61621915e+00 -9.74892788e-02 1.61915673e+00 -3.08134631 0.87999126 724.75 -1.78674031e+00 -6.74018409e-03 1.78675303e+00 -3.13782034 0.84534988 725.00 -2.26145638e+00 3.19129440e-01 2.28386264e+00 3.00140157 0.79846596 725.25 -2.07526776e+00 6.16153451e-01 2.16480515e+00 2.85297946 0.73820409 725.50 -1.24959822e+00 1.18931719e+00 1.72510031e+00 2.38090579 0.73340980 725.75 -1.01699612e+00 1.07169011e+00 1.47743048e+00 2.33001464 0.64564398 726.00 -7.99178166e-01 6.53785900e-01 1.03253172e+00 2.45592846 0.52219606 726.25 -7.18897338e-01 3.77508668e-01 8.11989026e-01 2.65805017 0.48536549 726.50 -8.78662831e-01 2.46200788e-01 9.12503808e-01 2.86839907 0.73398184 726.75 -9.76080376e-01 1.17332902e-01 9.83107273e-01 3.02195845 0.77597221 727.00 -1.04769867e+00 7.19453996e-05 1.04769867e+00 3.14152398 0.83238847 727.25 -1.04548345e+00 2.56908067e-02 1.04579905e+00 3.11702446 0.81745322 727.50 -1.00986703e+00 7.15609191e-02 1.01239932e+00 3.07084918 0.73214631 727.75 -1.01672215e+00 3.00568579e-02 1.01716633e+00 3.11203875 0.67882519 728.00 -9.52427990e-01 1.59279927e-01 9.65654789e-01 2.97589041 0.69769504 728.25 -8.73359242e-01 2.10475223e-01 8.98363058e-01 2.90510706 0.66895376 728.50 -7.28670383e-01 1.63977656e-01 7.46893031e-01 2.92024318 0.60678690 728.75 -7.35482750e-01 6.16166529e-02 7.38059271e-01 3.05801068 0.62809152 729.00 -7.41380132e-01 3.04175904e-02 7.42003862e-01 3.10058732 0.73518728 729.25 -6.37297702e-01 1.20257438e-03 6.37298836e-01 3.13970567 0.65488304 729.50 -5.26609790e-01 -4.82439441e-02 5.28815042e-01 -3.05023535 0.56113626 729.75 -4.22241579e-01 -2.64751074e-01 4.98378453e-01 -2.58154690 0.61400350 730.00 -3.92016145e-01 -3.12501926e-01 5.01332337e-01 -2.46858218 0.67399068 730.25 -3.88067547e-01 -4.42262134e-01 5.88381013e-01 -2.29101818 0.65788663 730.50 -4.04661869e-01 -5.79441942e-01 7.06756105e-01 -2.18042401 0.74145080 730.75 -5.11302294e-01 -7.75011428e-01 9.28478729e-01 -2.15398484 0.77478696 731.00 -5.77989548e-01 -8.08939481e-01 9.94210743e-01 -2.19118956 0.77655204 731.25 -5.54511486e-01 -8.12098138e-01 9.83354653e-01 -2.16989429 0.74483469 731.50 -5.49263446e-01 -7.17340052e-01 9.03475004e-01 -2.22426658 0.70015362 731.75 -5.31451372e-01 -5.91937302e-01 7.95506336e-01 -2.30240404 0.63509202 732.00 -5.30191392e-01 -5.29622509e-01 7.49401704e-01 -2.35673127 0.53232929 732.25 -5.18736864e-01 -6.05186039e-01 7.97080972e-01 -2.27942829 0.42194650 732.50 -4.05612469e-01 -6.80881824e-01 7.92541187e-01 -2.10806017 0.44670848 732.75 -2.65360912e-01 -8.20435904e-01 8.62282718e-01 -1.88361564 0.50607074 733.00 -1.45525077e-01 -8.98036618e-01 9.09751239e-01 -1.73144787 0.48704297 733.25 -9.23661470e-02 -9.80479362e-01 9.84820433e-01 -1.66472421 0.51797138 733.50 5.66450947e-02 -9.14573941e-01 9.16326449e-01 -1.50893930 0.56419652 733.75 4.26751920e-01 -1.18574519e+00 1.26020192e+00 -1.22532762 0.72247101 734.00 4.62016459e-01 -1.44409073e+00 1.51619828e+00 -1.26115153 0.78195703 734.25 3.24450580e-01 -1.81349944e+00 1.84229433e+00 -1.39376077 0.83414903 734.50 3.25469580e-01 -1.85742412e+00 1.88572395e+00 -1.39733108 0.82244762 734.75 2.99477160e-02 -2.05861284e+00 2.05883066e+00 -1.55624983 0.82551026 735.00 -1.58862765e-01 -2.18867714e+00 2.19443501e+00 -1.64325318 0.82183589 735.25 -5.50992089e-01 -2.26544028e+00 2.33148278e+00 -1.80938025 0.80642662 735.50 -6.81347219e-01 -2.09514467e+00 2.20314894e+00 -1.88521177 0.77504723 735.75 -1.03887745e+00 -1.44180703e+00 1.77709703e+00 -2.19517393 0.60854547 736.00 -1.09870110e+00 -1.20296377e+00 1.62919180e+00 -2.31092663 0.58775736 736.25 -9.37206305e-01 -7.66235148e-01 1.21056679e+00 -2.45622757 0.45904695 736.50 -9.66351499e-01 -3.54171187e-01 1.02920962e+00 -2.79029171 0.35907769 736.75 -8.30268367e-01 -3.35879793e-02 8.30947480e-01 -3.10116034 0.19556168 737.00 -1.61926783e-01 3.15324414e-01 3.54471112e-01 2.04520483 0.03062196 737.25 1.14146522e+00 1.20962188e+00 1.66316804e+00 0.81437947 0.38815257 737.50 2.11564046e+00 1.16261590e+00 2.41404439e+00 0.50248520 0.52761228 737.75 3.55900684e+00 1.17939084e+00 3.74933227e+00 0.31999334 0.68578533 738.00 4.43693038e+00 3.07185216e-01 4.44755146e+00 0.06912342 0.66819383 738.25 5.06339893e+00 -1.25695247e+00 5.21708139e+00 -0.24332417 0.78006413 738.50 4.91001054e+00 -1.96288356e+00 5.28782710e+00 -0.38030960 0.74293104 738.75 4.69727654e+00 -3.25429153e+00 5.71443963e+00 -0.60588003 0.82419072 739.00 4.54179812e+00 -3.38485241e+00 5.66437605e+00 -0.64046512 0.77369867 739.25 4.25273545e+00 -3.68995016e+00 5.63040771e+00 -0.71466059 0.76596373 739.50 3.86807443e+00 -3.48354657e+00 5.20548715e+00 -0.73314061 0.62296874 739.75 4.46570679e+00 -4.00623263e+00 5.99936972e+00 -0.73121642 0.66963423 740.00 4.13169380e+00 -3.95673412e+00 5.72072011e+00 -0.76377067 0.59449887 740.25 4.03777213e+00 -4.03963087e+00 5.71158659e+00 -0.78562828 0.53376230 740.50 2.84129391e+00 -4.65183222e+00 5.45091681e+00 -1.02248055 0.53024486 740.75 2.26006897e+00 -6.33240787e+00 6.72363750e+00 -1.22798322 0.64986257 741.00 1.63557720e+00 -6.40400370e+00 6.60956702e+00 -1.32074259 0.55250013 741.25 8.35852163e-01 -5.88889194e+00 5.94791536e+00 -1.42980104 0.38735841 741.50 -8.94417406e-01 -4.16524087e+00 4.26018943e+00 -1.78231790 0.26934392 741.75 -2.09714964e+00 -5.04405224e+00 5.46264585e+00 -1.96482048 0.46169339 742.00 -2.08719392e+00 -4.53951733e+00 4.99635828e+00 -2.00175614 0.51635882 742.25 -2.40642596e+00 -4.37121819e+00 4.98983310e+00 -2.07403568 0.60844308 742.50 -2.11125311e+00 -3.59546186e+00 4.16950066e+00 -2.10175046 0.56993890 742.75 -1.87208229e+00 -3.44627921e+00 3.92192969e+00 -2.06841803 0.56577118 743.00 -1.28086242e+00 -3.43818740e+00 3.66902455e+00 -1.92740856 0.45526493 743.25 -1.13415392e+00 -3.27703468e+00 3.46774587e+00 -1.90398497 0.44681429 743.50 -1.27432766e+00 -2.13249196e+00 2.48423689e+00 -2.10943214 0.24663217 743.75 -1.10646690e+00 -1.85801892e+00 2.16252244e+00 -2.10790704 0.19834306 744.00 -5.88504783e-01 -1.75368116e+00 1.84979337e+00 -1.89456980 0.14369445 744.25 -1.26565156e-01 -7.59682425e-01 7.70153313e-01 -1.73588278 0.02761945 744.50 7.93812399e-02 3.40485132e-01 3.49616227e-01 1.34174626 0.00506812 744.75 -4.70646917e-01 1.17330119e+00 1.26417728e+00 1.95227691 0.03877610 745.00 -1.06663201e+00 2.73057578e+00 2.93150949e+00 1.94319504 0.17435695 745.25 -2.19916907e+00 2.56257771e+00 3.37685491e+00 2.28002380 0.23436592 745.50 -3.29970348e+00 3.17367794e+00 4.57823926e+00 2.37566030 0.57762543 745.75 -3.26417077e+00 3.26000552e+00 4.61329024e+00 2.35683292 0.71995786 746.00 -3.60021717e+00 2.11615367e+00 4.17608309e+00 2.61020319 0.80465297 746.25 -3.05434604e+00 1.67887366e+00 3.48534739e+00 2.63900503 0.77476581 746.50 -2.52299481e+00 1.13648462e+00 2.76714657e+00 2.71836404 0.79270227 746.75 -2.41679804e+00 9.06140620e-01 2.58108574e+00 2.78287953 0.79417180 747.00 -2.22537842e+00 7.73259429e-01 2.35589458e+00 2.80717063 0.83043009 747.25 -2.01035600e+00 6.42725027e-01 2.11059866e+00 2.83215545 0.76784166 747.50 -1.56896501e+00 7.16336849e-01 1.72475787e+00 2.71329147 0.72712305 747.75 -1.33302798e+00 7.88734816e-01 1.54889193e+00 2.60730836 0.65720371 748.00 -7.29215932e-01 8.15067742e-01 1.09365959e+00 2.30065837 0.52633790 748.25 -4.07652670e-01 1.04887423e+00 1.12530789e+00 1.94148647 0.50926642 748.50 -4.41295478e-02 1.04902105e+00 1.04994884e+00 1.61283890 0.40557031 748.75 4.41082162e-01 3.68521508e-01 5.74770890e-01 0.69601208 0.13946966 749.00 8.19329287e-01 -2.90333188e-01 8.69249010e-01 -0.34054901 0.33809831 749.25 9.44222781e-01 -5.41694910e-01 1.08857248e+00 -0.52085221 0.44800358 749.50 8.00280780e-01 -9.46348555e-01 1.23936472e+00 -0.86883240 0.44950801 749.75 4.20560702e-01 -1.35323837e+00 1.41708341e+00 -1.26947834 0.56306126 750.00 3.44446169e-01 -1.56296802e+00 1.60047249e+00 -1.35388404 0.66052497 750.25 1.53699561e-01 -1.55246874e+00 1.56005857e+00 -1.47211458 0.58812793 750.50 7.09978532e-02 -1.49337084e+00 1.49505757e+00 -1.52329009 0.51202732 750.75 -3.92618278e-01 -9.37359469e-01 1.01626369e+00 -1.96745114 0.30582300 751.00 -9.16024412e-01 -1.13730816e+00 1.46033235e+00 -2.24884071 0.49403273 751.25 -1.13871687e+00 -1.26380998e+00 1.70114425e+00 -2.30417416 0.45341021 751.50 -1.05797197e+00 -9.77321351e-01 1.44029918e+00 -2.39579981 0.31707732 751.75 -1.32691340e+00 -6.38289525e-01 1.47245125e+00 -2.69323321 0.42660345 752.00 -1.29827739e+00 -3.48276057e-01 1.34418019e+00 -2.87950318 0.38056502 752.25 -1.01165781e+00 3.52911545e-01 1.07144673e+00 2.80594736 0.28656550 752.50 -5.41831679e-01 8.09541313e-01 9.74134850e-01 2.16062464 0.28162933 752.75 2.29887903e-01 1.19031601e+00 1.21231211e+00 1.38001342 0.35164203 753.00 6.42198247e-01 1.34121557e+00 1.48703658e+00 1.12423740 0.47840900 753.25 7.15683016e-01 9.40538641e-01 1.18186933e+00 0.92033735 0.32372188 753.50 5.97378963e-01 1.10601736e+00 1.25703461e+00 1.07557235 0.32255891 753.75 1.32539465e+00 7.23811401e-01 1.51015692e+00 0.49985182 0.26732073 754.00 1.76905164e+00 3.40761235e-01 1.80157207e+00 0.19029299 0.29584100 754.25 1.91046076e+00 2.81105168e-01 1.93103092e+00 0.14609170 0.28681346 754.50 2.01187890e+00 3.89960830e-01 2.04932334e+00 0.19145510 0.27067822 754.75 1.72764844e+00 -2.32006777e-02 1.72780422e+00 -0.01342824 0.15823931 755.00 1.44735199e+00 -5.42643313e-01 1.54573269e+00 -0.35870181 0.11130269 755.25 2.87466188e-01 -1.96775037e-01 3.48363639e-01 -0.60025785 0.00412810 755.50 -1.05149842e+00 -1.63256924e-01 1.06409668e+00 -2.98756128 0.03159168 755.75 -3.93643359e+00 -4.27775557e-02 3.93666602e+00 -3.13072600 0.36268538 756.00 -4.03979030e+00 -3.73931491e-02 4.03996335e+00 -3.13233671 0.49115319 756.25 -3.38034105e+00 1.20265284e-01 3.38247976e+00 3.10602980 0.69301308 756.50 -2.88026868e+00 4.39713186e-01 2.91363954e+00 2.99009840 0.67401408 756.75 -2.35502193e+00 1.30294391e+00 2.69142920e+00 2.63624855 0.72828905 757.00 -1.95335345e+00 1.39451234e+00 2.40005300e+00 2.52159411 0.76557315 757.25 -1.24362494e+00 1.52667608e+00 1.96909696e+00 2.25437440 0.76562046 757.50 -8.92109091e-01 1.64475202e+00 1.87111406e+00 2.06778382 0.77522797 757.75 -2.37647875e-01 1.60092018e+00 1.61846283e+00 1.71816471 0.73855694 758.00 1.45840638e-01 1.31938354e+00 1.32741945e+00 1.46070630 0.65982327 758.25 5.30767865e-01 1.21823275e+00 1.32883617e+00 1.15990884 0.76955793 758.50 8.70561709e-01 1.16009408e+00 1.45041234e+00 0.92702431 0.76001431 758.75 1.34997097e+00 8.11491921e-01 1.57510024e+00 0.54124119 0.81483896 759.00 1.43922418e+00 3.50569005e-01 1.48130512e+00 0.23892907 0.76237765 759.25 1.63457458e+00 -2.96873367e-01 1.66131510e+00 -0.17966280 0.78485293 759.50 1.48982253e+00 -6.73949361e-01 1.63516939e+00 -0.42482215 0.78826684 759.75 1.26861336e+00 -9.65167844e-01 1.59402911e+00 -0.65038075 0.84243706 760.00 8.61270014e-01 -1.00679484e+00 1.32492335e+00 -0.86314253 0.74616058 760.25 4.95795754e-01 -8.80551604e-01 1.01053677e+00 -1.05798815 0.76662458 760.50 4.11539329e-01 -8.89433821e-01 9.80029153e-01 -1.13743299 0.81378565 760.75 3.40595251e-01 -8.62462628e-01 9.27279305e-01 -1.19468543 0.84051876 761.00 2.37867903e-01 -7.39544912e-01 7.76857655e-01 -1.25960560 0.83736555 761.25 1.84284939e-01 -6.68756024e-01 6.93682607e-01 -1.30190605 0.84627549 761.50 1.76301233e-01 -5.79510942e-01 6.05735138e-01 -1.27546867 0.74211119 761.75 1.59519305e-01 -5.05643883e-01 5.30209529e-01 -1.26520110 0.72918281 762.00 6.08504807e-02 -4.32412215e-01 4.36672766e-01 -1.43099104 0.66236769 762.25 5.28267001e-02 -3.68262067e-01 3.72031733e-01 -1.42831963 0.64995175 762.50 9.80213203e-02 -2.90373162e-01 3.06471455e-01 -1.24523747 0.54225496 762.75 1.03648211e-01 -3.04616332e-01 3.21767092e-01 -1.24282638 0.57558485 763.00 7.16955621e-02 -2.59647620e-01 2.69364326e-01 -1.30138321 0.47006735 763.25 8.78131986e-02 -2.36518075e-01 2.52293396e-01 -1.21529559 0.51634463 763.50 8.01504543e-02 -2.10851495e-01 2.25571382e-01 -1.20753790 0.42238874 763.75 4.30378119e-02 -1.82714555e-01 1.87714842e-01 -1.33946633 0.31310561 764.00 3.25752965e-02 -9.57831263e-02 1.01170931e-01 -1.24297328 0.12234126 764.25 1.79213122e-02 -2.79525378e-02 3.32041834e-02 -1.00067932 0.01145191 764.50 -8.26963810e-03 1.36027522e-01 1.36278661e-01 1.63151546 0.20963662 764.75 -5.24720350e-05 1.90581649e-01 1.90581656e-01 1.57107165 0.38440829 765.00 -4.40059968e-03 3.67208788e-01 3.67235155e-01 1.58277967 0.59427686 765.25 3.87370930e-02 4.43429315e-01 4.45118096e-01 1.48365955 0.66558227 765.50 1.99071013e-01 5.28132522e-01 5.64405199e-01 1.21033132 0.58936401 765.75 3.52205478e-01 6.41613845e-01 7.31926926e-01 1.06876973 0.67482421 766.00 6.55426427e-01 6.42643348e-01 9.17918446e-01 0.77555072 0.72972947 766.25 8.33196458e-01 5.73221407e-01 1.01133531e+00 0.60261233 0.75928303 766.50 1.15080342e+00 4.14978310e-01 1.22333786e+00 0.34608556 0.83425690 766.75 1.25725264e+00 2.64343877e-01 1.28474195e+00 0.20723658 0.84789378 767.00 1.28850618e+00 1.14677135e-01 1.29359925e+00 0.08876619 0.78852471 767.25 1.26896027e+00 -4.09801572e-02 1.26962181e+00 -0.03228306 0.78098986 767.50 1.34584109e+00 -3.55005090e-01 1.39187530e+00 -0.25790483 0.79229696 767.75 1.39524198e+00 -6.60718935e-01 1.54377773e+00 -0.44226583 0.74288514 768.00 1.18504909e+00 -1.27747308e+00 1.74249213e+00 -0.82291280 0.75309468 768.25 8.92020799e-01 -1.44860982e+00 1.70122647e+00 -1.01885669 0.69917142 768.50 1.25659325e-01 -1.55191980e+00 1.55699883e+00 -1.49000234 0.63300068 768.75 -2.04947507e-01 -1.44591945e+00 1.46037206e+00 -1.71160037 0.63943772 769.00 -6.36777531e-01 -1.39509422e+00 1.53354932e+00 -1.99899327 0.69189181 769.25 -9.72032773e-01 -1.16166388e+00 1.51469821e+00 -2.26755294 0.64305260 769.50 -1.28532263e+00 -8.26802971e-01 1.52828578e+00 -2.56996669 0.69583315 769.75 -1.47094455e+00 -3.80183303e-01 1.51928181e+00 -2.88866573 0.58391618 770.00 -1.98952157e+00 2.57579639e-01 2.00612646e+00 3.01284072 0.60539198 770.25 -1.99478531e+00 7.60243324e-01 2.13474550e+00 2.77747138 0.65300288 770.50 -2.36426875e+00 1.05149201e+00 2.58754752e+00 2.72311903 0.72391117 770.75 -2.23013891e+00 1.26023987e+00 2.56158625e+00 2.62723427 0.61691001 771.00 -1.95881776e+00 1.56806296e+00 2.50914098e+00 2.46653778 0.43912278 771.25 -1.38162938e+00 2.24792320e+00 2.63857129e+00 2.12190002 0.34957483 771.50 -3.35572154e-01 2.85437028e+00 2.87402825e+00 1.68782348 0.34829949 771.75 7.54187313e-01 1.42860052e+00 1.61545595e+00 1.08506271 0.14354746 772.00 1.64576540e+00 8.47194301e-01 1.85102187e+00 0.47539542 0.20625670 772.25 1.79454079e+00 4.80643033e-01 1.85779288e+00 0.26169399 0.28523972 772.50 2.08864316e+00 7.94983956e-01 2.23482208e+00 0.36369059 0.38462781 772.75 2.42052572e+00 1.76108320e-01 2.42692376e+00 0.07262826 0.44776844 773.00 2.81964255e+00 -3.91991921e-02 2.81991502e+00 -0.01390129 0.55638197 773.25 2.85542382e+00 -2.34910376e-01 2.86507034e+00 -0.08208328 0.58246064 773.50 2.78437445e+00 -7.22638942e-01 2.87662096e+00 -0.25393121 0.56981085 773.75 2.73038430e+00 -1.03230881e+00 2.91901694e+00 -0.36146985 0.63847940 774.00 2.74937347e+00 -1.39599612e+00 3.08348175e+00 -0.46982887 0.74625578 774.25 2.31460299e+00 -2.04986805e+00 3.09181921e+00 -0.72481557 0.77179115 774.50 2.04189326e+00 -2.16770612e+00 2.97796539e+00 -0.81527640 0.76584214 774.75 1.57348040e+00 -2.35495365e+00 2.83225127e+00 -0.98176218 0.79057368 775.00 1.33795639e+00 -2.26864533e+00 2.63379553e+00 -1.03794022 0.79049665 775.25 9.04723949e-01 -2.31395568e+00 2.48453543e+00 -1.19808483 0.82129511 775.50 7.03994157e-01 -2.34820094e+00 2.45145986e+00 -1.27952166 0.85858384 775.75 2.81945856e-01 -2.34359596e+00 2.36049475e+00 -1.45106693 0.89841643 776.00 1.28337616e-01 -2.24763699e+00 2.25129798e+00 -1.51375935 0.89762755 776.25 -1.16647501e-01 -2.02578399e+00 2.02913958e+00 -1.62831423 0.91711153 776.50 -3.26150326e-01 -1.81286540e+00 1.84197041e+00 -1.74880087 0.90268818 776.75 -6.13552089e-01 -1.50581323e+00 1.62601342e+00 -1.95771341 0.93416917 777.00 -6.94904088e-01 -1.41398947e+00 1.57551830e+00 -2.02757998 0.92391132 777.25 -7.60159907e-01 -1.05921163e+00 1.30375318e+00 -2.19328037 0.88235028 777.50 -7.20903917e-01 -8.40022573e-01 1.10695094e+00 -2.28002932 0.87176956 777.75 -6.26975942e-01 -5.95216210e-01 8.64512099e-01 -2.38217452 0.85514868 778.00 -5.11080205e-01 -5.10258424e-01 7.22195704e-01 -2.35699910 0.80093718 778.25 -3.71065318e-01 -4.31777556e-01 5.69316545e-01 -2.28071658 0.74876280 778.50 -3.30652050e-01 -4.10774622e-01 5.27320177e-01 -2.24854683 0.68021913 778.75 -3.02617089e-01 -3.40668245e-01 4.55666497e-01 -2.29711205 0.60670074 779.00 -3.09200714e-01 -4.07341436e-01 5.11402119e-01 -2.22007709 0.64676619 779.25 -3.35309383e-01 -4.69433811e-01 5.76888624e-01 -2.19104513 0.73478171 779.50 -4.81619416e-01 -4.57292707e-01 6.64133933e-01 -2.38209816 0.74412855 779.75 -6.83893194e-01 -2.79884923e-01 7.38948896e-01 -2.75313561 0.76488353 780.00 -6.87364976e-01 -9.79851602e-02 6.94313835e-01 -2.99999478 0.74712229 780.25 -6.63983264e-01 9.77300549e-02 6.71137049e-01 2.99545442 0.75166865 780.50 -5.64354749e-01 2.57856116e-01 6.20472448e-01 2.71301196 0.62881811 780.75 -3.20362017e-01 5.49380991e-01 6.35964854e-01 2.09872106 0.68979740 781.00 -1.30564351e-01 5.17967453e-01 5.34169760e-01 1.81772281 0.58035902 781.25 7.96798000e-02 4.35215815e-01 4.42449631e-01 1.38972057 0.43208940 781.50 2.72576829e-01 2.12722167e-01 3.45758367e-01 0.66268226 0.28827281 781.75 2.92227421e-01 -3.72094039e-02 2.94586838e-01 -0.12664878 0.23887932 782.00 1.39764731e-01 -5.10844510e-02 1.48807934e-01 -0.35041879 0.06108086 782.25 2.42489571e-02 -6.56801697e-02 7.00135459e-02 -1.21712242 0.01416488 782.50 -3.17894447e-01 -2.04591132e-02 3.18552122e-01 -3.07732309 0.15568987 782.75 -5.89789505e-01 7.42716167e-02 5.94447586e-01 3.01632303 0.33209736 783.00 -7.51619975e-01 4.30658546e-01 8.66255949e-01 2.62128246 0.32429776 783.25 -6.10479772e-01 8.02431212e-01 1.00825662e+00 2.22116587 0.40194985 783.50 -3.59007576e-01 1.03338823e+00 1.09397334e+00 1.90516036 0.42061430 783.75 -3.69838089e-01 1.23229972e+00 1.28660126e+00 1.86236343 0.47939852 784.00 3.85005623e-01 1.63023744e+00 1.67508311e+00 1.33888028 0.54539277 784.25 1.11731033e+00 2.00165831e+00 2.29238268e+00 1.06168518 0.74470452 784.50 1.61845491e+00 1.78702603e+00 2.41098700e+00 0.83485774 0.71501058 784.75 1.93989307e+00 1.66569231e+00 2.55689578e+00 0.70949538 0.72292610 785.00 2.76041132e+00 1.28319806e+00 3.04408737e+00 0.43514055 0.73358976 785.25 3.18329147e+00 7.66799570e-01 3.27434363e+00 0.23637936 0.73890489 785.50 3.49455222e+00 -8.94220722e-02 3.49569614e+00 -0.02558341 0.80067044 785.75 3.74115095e+00 -3.72317294e-01 3.75963171e+00 -0.09919284 0.80800534 786.00 3.84022934e+00 -1.46875444e+00 4.11152052e+00 -0.36529947 0.81945385 786.25 3.52429947e+00 -2.21645473e+00 4.16333500e+00 -0.56140353 0.82300710 786.50 2.64670345e+00 -3.23289339e+00 4.17811427e+00 -0.88476879 0.82835170 786.75 1.95230755e+00 -3.67848719e+00 4.16446549e+00 -1.08286291 0.85094566 787.00 4.26008813e-01 -4.28616045e+00 4.30727930e+00 -1.47172998 0.87566213 787.25 -2.71422706e-01 -3.93971257e+00 3.94905121e+00 -1.63958167 0.84321441 787.50 -1.26165794e+00 -3.12620012e+00 3.37118791e+00 -1.95438127 0.88866501 787.75 -1.52302169e+00 -2.71829481e+00 3.11588218e+00 -2.08150211 0.89044672 788.00 -1.58036608e+00 -2.08389632e+00 2.61537394e+00 -2.21963325 0.88330508 788.25 -1.62940115e+00 -1.89761286e+00 2.50117626e+00 -2.28029559 0.91785784 788.50 -1.73271881e+00 -1.74102447e+00 2.45631445e+00 -2.35380351 0.93791375 788.75 -1.74169203e+00 -1.62854464e+00 2.38445984e+00 -2.38975442 0.92717509 789.00 -1.87404141e+00 -1.37238660e+00 2.32281643e+00 -2.50950706 0.90635584 789.25 -2.01133063e+00 -1.20466048e+00 2.34449521e+00 -2.60195509 0.90423745 789.50 -2.03744472e+00 -8.49360035e-01 2.20739517e+00 -2.74662392 0.91522064 789.75 -1.99955813e+00 -6.59698725e-01 2.10557240e+00 -2.82291521 0.88414602 790.00 -1.75675696e+00 -5.11073302e-01 1.82958764e+00 -2.85848809 0.81699348 790.25 -1.53037253e+00 -4.53652954e-01 1.59619581e+00 -2.85341152 0.75474782 790.50 -1.60475189e+00 -7.34218336e-01 1.76473941e+00 -2.71249641 0.79790745 790.75 -1.94807517e+00 -1.23739936e+00 2.30784619e+00 -2.57569869 0.76819276 791.00 -2.83682157e+00 -1.67369878e+00 3.29375533e+00 -2.60856533 0.86355590 791.25 -3.68648174e+00 -1.49097042e+00 3.97657396e+00 -2.75726229 0.85964132 791.50 -4.72542163e+00 -7.89284894e-01 4.79088512e+00 -2.97609095 0.83330870 791.75 -5.44504121e+00 6.62036423e-01 5.48514047e+00 3.02060132 0.83155682 792.00 -5.49777891e+00 2.39221747e+00 5.99568823e+00 2.73117794 0.87283402 792.25 -4.84132918e+00 3.89186277e+00 6.21168770e+00 2.46448844 0.87243320 792.50 -4.43809792e+00 4.82091174e+00 6.55270197e+00 2.31487302 0.89774593 792.75 -2.79140276e+00 5.36625943e+00 6.04885689e+00 2.05045464 0.86246078 793.00 -1.78889772e+00 5.69096317e+00 5.96550222e+00 1.87535667 0.89171676 793.25 -5.96330916e-01 6.19573165e+00 6.22436352e+00 1.66674943 0.90682818 793.50 4.48874866e-01 6.04781499e+00 6.06445009e+00 1.49671117 0.92390735 793.75 1.56993352e+00 5.13738098e+00 5.37190604e+00 1.27421879 0.92890692 794.00 1.90592522e+00 4.61781576e+00 4.99567546e+00 1.17936160 0.94060831 794.25 2.20112594e+00 4.14276582e+00 4.69121136e+00 1.08240937 0.91957916 794.50 2.43770189e+00 3.90944791e+00 4.60718716e+00 1.01324672 0.92642821 794.75 2.95936996e+00 3.21460816e+00 4.36939082e+00 0.82671560 0.91630966 795.00 3.23261977e+00 2.90046687e+00 4.34310242e+00 0.73129348 0.89732209 795.25 3.61511270e+00 2.25565739e+00 4.26110668e+00 0.55784546 0.88994942 795.50 3.69555610e+00 1.83025258e+00 4.12394949e+00 0.45984657 0.90077036 795.75 3.81173518e+00 1.18596056e+00 3.99197038e+00 0.30163995 0.87110572 796.00 4.06854643e+00 7.26954828e-01 4.13298117e+00 0.17681096 0.87934462 796.25 4.13708433e+00 -9.16571865e-02 4.13809954e+00 -0.02215140 0.87167586 796.50 4.05711225e+00 -5.56633921e-01 4.09511918e+00 -0.13634826 0.85193246 796.75 4.15115320e+00 -1.58134477e+00 4.44215310e+00 -0.36396909 0.88844564 797.00 3.79786262e+00 -1.86489052e+00 4.23102554e+00 -0.45645142 0.90046967 797.25 3.04315035e+00 -3.17724123e+00 4.39950291e+00 -0.80695149 0.81726809 797.50 2.15166042e+00 -3.62038084e+00 4.21150804e+00 -1.03456465 0.77820573 797.75 8.04036077e-01 -3.96089125e+00 4.04167460e+00 -1.37052385 0.80655414 798.00 3.03381833e-01 -4.14127468e+00 4.15237240e+00 -1.49766888 0.84956623 798.25 -9.82172590e-01 -4.26646898e+00 4.37806128e+00 -1.79706165 0.81674076 798.50 -1.38253054e+00 -4.01587428e+00 4.24719165e+00 -1.90235415 0.83419719 798.75 -2.04165746e+00 -3.73024588e+00 4.25242278e+00 -2.07158361 0.75099488 799.00 -3.07858789e+00 -2.93293532e+00 4.25203634e+00 -2.38041865 0.69059942 799.25 -3.65893247e+00 -1.20850856e+00 3.85334656e+00 -2.82258366 0.65495943 799.50 -3.77762916e+00 -8.96606367e-01 3.88257453e+00 -2.90855834 0.65482583 799.75 -3.83899733e+00 -2.44253061e-01 3.84675968e+00 -3.07805412 0.69112198 800.00 -3.38511494e+00 1.96755814e-01 3.39082822e+00 3.08353416 0.64212538 800.25 -3.37829025e+00 2.64742358e-01 3.38864774e+00 3.06338670 0.59299911 800.50 -3.58649626e+00 3.80752712e-02 3.58669836e+00 3.13097677 0.58547215 800.75 -4.33185056e+00 3.78765435e-01 4.34837815e+00 3.05437714 0.59199459 801.00 -5.11015805e+00 6.01341601e-01 5.14541806e+00 3.02445563 0.57662740 801.25 -6.25475400e+00 2.21113717e+00 6.63408435e+00 2.80179160 0.52654695 801.50 -4.76426736e+00 6.14756599e+00 7.77758388e+00 2.23009661 0.55128036 801.75 -3.00142443e+00 7.28804766e+00 7.88188983e+00 1.96145776 0.65196899 802.00 -1.45120263e+00 7.51562440e+00 7.65444963e+00 1.76154029 0.59360283 802.25 1.73396231e+00 6.93531784e+00 7.14879422e+00 1.32579963 0.50440783 802.50 5.48453661e+00 7.46184272e+00 9.26062842e+00 0.93695738 0.64704284 802.75 7.03068468e+00 7.84818731e+00 1.05368198e+01 0.84028683 0.77307499 803.00 7.11118693e+00 4.49133258e+00 8.41076975e+00 0.56332195 0.76787066 803.25 6.41522048e+00 3.47838684e+00 7.29754950e+00 0.49684155 0.87003706 803.50 6.44303370e+00 3.17884550e+00 7.18454884e+00 0.45833529 0.90137388 803.75 6.04558493e+00 2.58050990e+00 6.57328902e+00 0.40342985 0.85034647 804.00 5.63100145e+00 1.10585845e+00 5.73856256e+00 0.19391963 0.76672176 804.25 5.47245915e+00 1.82299774e-01 5.47549471e+00 0.03329991 0.84795692 804.50 4.90998757e+00 -4.02235617e-01 4.92643598e+00 -0.08173939 0.86188231 804.75 4.46572512e+00 -7.86394753e-01 4.53443685e+00 -0.17430856 0.87219137 805.00 3.23664784e+00 -8.78623952e-01 3.35378433e+00 -0.26507315 0.82421439 805.25 2.77410189e+00 -7.86282389e-01 2.88338018e+00 -0.27619274 0.82348536 805.50 2.21204878e+00 -5.16973911e-01 2.27165618e+00 -0.22958740 0.74992532 805.75 1.97978881e+00 -2.31838122e-01 1.99331700e+00 -0.11657154 0.67679319 806.00 1.40484067e+00 2.63819306e-01 1.42939775e+00 0.18563103 0.62064441 806.25 1.19365712e+00 6.14366541e-01 1.34248410e+00 0.47533252 0.59558458 806.50 1.27804774e+00 1.31737421e+00 1.83545113e+00 0.80054925 0.67800803 806.75 1.38737674e+00 1.55192753e+00 2.08165638e+00 0.84132269 0.74417199 807.00 1.71234259e+00 1.98912157e+00 2.62463745e+00 0.86003480 0.80671953 807.25 1.91877343e+00 2.21937918e+00 2.93382607e+00 0.85791329 0.82088504 807.50 2.70736663e+00 2.63675842e+00 3.77919688e+00 0.77218663 0.88938541 807.75 3.01580685e+00 2.75240038e+00 4.08298895e+00 0.73976464 0.89629588 808.00 3.48598502e+00 2.94121300e+00 4.56101146e+00 0.70083985 0.85584177 808.25 3.84478108e+00 3.25129787e+00 5.03520401e+00 0.70195698 0.87147063 808.50 4.22641755e+00 3.32621407e+00 5.37831808e+00 0.66676712 0.85774039 808.75 5.00064636e+00 3.11642527e+00 5.89224664e+00 0.55730712 0.84772523 809.00 6.12954429e+00 3.03486322e+00 6.83971549e+00 0.45973642 0.86448192 809.25 7.35935073e+00 2.48173591e+00 7.76653438e+00 0.32524638 0.77767062 809.50 1.03476821e+01 1.54334333e+00 1.04621429e+01 0.14805728 0.83981377 809.75 1.03483894e+01 9.69112408e-01 1.03936683e+01 0.09337629 0.81551010 810.00 1.03456943e+01 -2.42455190e+00 1.06259984e+01 -0.23019941 0.71152191 810.25 8.31629507e+00 -4.69901972e+00 9.55204429e+00 -0.51431507 0.65176883 810.50 7.54216234e+00 -7.38249894e+00 1.05539331e+01 -0.77470061 0.71642439 810.75 5.08870262e+00 -8.69763657e+00 1.00768932e+01 -1.04142913 0.65885317 811.00 3.35086729e+00 -1.23158809e+01 1.27635901e+01 -1.30514968 0.79047535 811.25 1.38007112e+00 -9.70081675e+00 9.79849182e+00 -1.42948119 0.59458477 811.50 -2.97134942e+00 -8.55393260e+00 9.05531227e+00 -1.90512310 0.61827496 811.75 -3.78082961e+00 -7.01283477e+00 7.96709006e+00 -2.06525576 0.60335659 812.00 -4.68728376e+00 -5.93634851e+00 7.56378627e+00 -2.23915764 0.68395411 812.25 -5.02739818e+00 -4.50129964e+00 6.74806868e+00 -2.41135050 0.58429567 812.50 -4.89055689e+00 -3.57819855e+00 6.05978973e+00 -2.50993634 0.59241455 812.75 -4.11806358e+00 -1.99934462e+00 4.57775344e+00 -2.68960732 0.45086561 813.00 -3.74106001e+00 -4.25957243e-01 3.76523167e+00 -3.02822085 0.38007721 813.25 -2.73505374e+00 7.29470221e-01 2.83066172e+00 2.88094843 0.36263340 813.50 -2.16861429e+00 1.36606391e+00 2.56300966e+00 2.57945975 0.31493511 813.75 -1.88524997e+00 1.46020281e+00 2.38460892e+00 2.48256961 0.20932726 814.00 -1.38115471e+00 1.47731842e+00 2.02238920e+00 2.32256554 0.21880169 814.25 -9.17997904e-01 8.99660915e-01 1.28534428e+00 2.36628239 0.10065556 814.50 -1.17367555e+00 8.46505397e-01 1.44709560e+00 2.51675139 0.08164417 814.75 -1.16901496e-01 3.38768894e+00 3.38970534e+00 1.60529038 0.25957091 815.00 4.80723957e-01 4.07947217e+00 4.10769872e+00 1.45349753 0.39738383 815.25 8.97057901e-01 4.32788451e+00 4.41987524e+00 1.36641643 0.40601436 815.50 2.03668838e+00 4.86068795e+00 5.27014107e+00 1.17400817 0.51255591 815.75 4.10677253e+00 2.83444600e+00 4.98995638e+00 0.60411047 0.46230507 816.00 4.22112676e+00 2.17416542e+00 4.74814768e+00 0.47562886 0.49149903 816.25 4.71479913e+00 1.05451704e+00 4.83128731e+00 0.22003967 0.44317411 816.50 5.31920401e+00 8.32080662e-01 5.38389168e+00 0.15517200 0.49368899 816.75 6.07251591e+00 -6.49791055e-01 6.10718248e+00 -0.10659962 0.54377229 817.00 5.71488384e+00 -1.40527418e+00 5.88512470e+00 -0.24111353 0.52649773 817.25 6.40460891e+00 -1.55477651e+00 6.59062556e+00 -0.23815209 0.62300288 817.50 6.53062419e+00 -1.61159689e+00 6.72653677e+00 -0.24194138 0.60312772 817.75 5.60557334e+00 -2.11374978e+00 5.99085892e+00 -0.36059301 0.59030210 818.00 4.45485177e+00 -3.16013552e+00 5.46188253e+00 -0.61698651 0.61483510 818.25 3.58878232e+00 -4.95394620e+00 6.11726585e+00 -0.94386251 0.72257852 818.50 3.15936560e+00 -4.54922256e+00 5.53868368e+00 -0.96378148 0.61904428 818.75 1.90837032e+00 -5.17025371e+00 5.51120683e+00 -1.21720321 0.58384695 819.00 1.95415325e+00 -4.85229121e+00 5.23100802e+00 -1.18794049 0.63955214 819.25 2.31629634e+00 -4.92146338e+00 5.43930423e+00 -1.13090158 0.69487100 819.50 2.29970547e+00 -4.94631840e+00 5.45478789e+00 -1.13559394 0.68002795 819.75 1.37277047e+00 -4.94854910e+00 5.13542957e+00 -1.30019217 0.71665839 820.00 1.21215936e+00 -5.35240192e+00 5.48794466e+00 -1.34808300 0.78751725 820.25 1.07597206e+00 -6.18470387e+00 6.27760129e+00 -1.39854723 0.80146321 820.50 -1.83406381e-02 -6.52949293e+00 6.52951869e+00 -1.57360521 0.80666277 820.75 -1.36364830e+00 -6.87764853e+00 7.01153236e+00 -1.76653024 0.88615347 821.00 -1.83169149e+00 -6.25157976e+00 6.51439508e+00 -1.85581565 0.86133220 821.25 -2.70446532e+00 -5.50517575e+00 6.13360356e+00 -2.02742645 0.89500150 821.50 -2.72782905e+00 -4.93447971e+00 5.63827468e+00 -2.07579426 0.86712243 821.75 -3.02189251e+00 -4.44596245e+00 5.37572473e+00 -2.16776348 0.86107982 822.00 -3.23208957e+00 -4.21770449e+00 5.31370249e+00 -2.22465743 0.86628491 822.25 -3.87247996e+00 -3.77018936e+00 5.40466732e+00 -2.36957784 0.88585658 822.50 -4.18431977e+00 -3.50355282e+00 5.45741828e+00 -2.44451488 0.90567875 822.75 -4.19894974e+00 -3.09201801e+00 5.21457134e+00 -2.50686619 0.89130231 823.00 -4.49813906e+00 -2.59218737e+00 5.19159805e+00 -2.61879699 0.89247353 823.25 -4.41703200e+00 -1.90059877e+00 4.80858060e+00 -2.73525101 0.88910406 823.50 -4.02889740e+00 -1.43648639e+00 4.27732480e+00 -2.79909834 0.90794378 823.75 -3.94611080e+00 -1.07734567e+00 4.09053348e+00 -2.87507323 0.93537354 824.00 -3.80222167e+00 -9.14236089e-01 3.91059040e+00 -2.90562424 0.91415872 824.25 -3.68447792e+00 -6.99653454e-01 3.75031899e+00 -2.95393480 0.89117527 824.50 -3.86061723e+00 -6.42732210e-01 3.91375396e+00 -2.97662141 0.90335085 824.75 -3.94208391e+00 -7.62358659e-01 4.01512344e+00 -2.95056110 0.93622024 825.00 -4.11128401e+00 -7.76083350e-01 4.18389311e+00 -2.95501900 0.92854527 825.25 -4.40908645e+00 -6.00606548e-01 4.44980579e+00 -3.00620578 0.93620142 825.50 -4.65616526e+00 -2.76013212e-01 4.66433899e+00 -3.08238286 0.89181339 825.75 -5.03955307e+00 -4.52546885e-02 5.03975626e+00 -3.13261299 0.89871673 826.00 -5.48739771e+00 9.81199796e-01 5.57443151e+00 2.96465292 0.92144923 826.25 -5.52758350e+00 1.69963694e+00 5.78298755e+00 2.84328511 0.92619764 826.50 -4.85518281e+00 2.18909400e+00 5.32587389e+00 2.71800901 0.91417064 826.75 -4.72096761e+00 2.63653239e+00 5.40729491e+00 2.63226763 0.92633427 827.00 -4.57378617e+00 3.20399821e+00 5.58436428e+00 2.53052225 0.93038964 827.25 -4.39875670e+00 3.33537133e+00 5.52030456e+00 2.49283039 0.93825084 827.50 -4.17827828e+00 3.50759342e+00 5.45538459e+00 2.44323605 0.95607693 827.75 -4.13680167e+00 3.66934122e+00 5.52966482e+00 2.41600673 0.95333233 828.00 -4.43992016e+00 4.05841791e+00 6.01528445e+00 2.40105577 0.94606914 828.25 -4.40714065e+00 4.25953438e+00 6.12915343e+00 2.37322432 0.92973332 828.50 -4.64306028e+00 5.06548426e+00 6.87147288e+00 2.31271138 0.93611759 828.75 -4.44113691e+00 5.87704500e+00 7.36636647e+00 2.21791965 0.93428321 829.00 -4.17632888e+00 7.70863955e+00 8.76725992e+00 2.06730090 0.92282881 829.25 -3.54761930e+00 8.90890546e+00 9.58927522e+00 1.94975904 0.90909368 829.50 -1.87909152e+00 1.03154664e+01 1.04852197e+01 1.75098314 0.94616488 829.75 -7.42455064e-01 1.06311091e+01 1.06570033e+01 1.64052109 0.92576544 830.00 1.86224124e+00 1.11732774e+01 1.13274035e+01 1.40564518 0.92344518 830.25 3.53005021e+00 1.05940020e+01 1.11666527e+01 1.24915484 0.91828155 830.50 5.89004111e+00 8.92085406e+00 1.06899121e+01 0.98724551 0.90351130 830.75 6.92371446e+00 8.18727136e+00 1.07223707e+01 0.86882252 0.90494444 831.00 7.52656892e+00 6.06281360e+00 9.66472703e+00 0.67809870 0.92184987 831.25 8.17276727e+00 4.88768871e+00 9.52279506e+00 0.53898131 0.91960419 831.50 8.48245596e+00 3.18732688e+00 9.06151818e+00 0.35943259 0.92436403 831.75 7.80535639e+00 2.02329793e+00 8.06333199e+00 0.25363652 0.91629243 832.00 6.95765780e+00 1.17544757e+00 7.05625106e+00 0.16736267 0.92500382 832.25 6.53295805e+00 5.65507839e-01 6.55738820e+00 0.08634706 0.87709600 832.50 5.91060499e+00 1.96679622e-01 5.91387642e+00 0.03326344 0.85199109 832.75 5.15308437e+00 9.48317578e-02 5.15395689e+00 0.01840083 0.83285022 833.00 4.35779914e+00 4.28481057e-01 4.37881369e+00 0.09801007 0.84955841 833.25 4.25045742e+00 7.32860501e-01 4.31317433e+00 0.17074047 0.88415618 833.50 4.26612917e+00 6.55677316e-01 4.31622182e+00 0.15250043 0.88710971 833.75 4.32446017e+00 7.93331413e-01 4.39662718e+00 0.18143470 0.87960612 834.00 4.51116352e+00 9.99646154e-01 4.62059398e+00 0.21807008 0.89956422 834.25 4.94916586e+00 1.17730797e+00 5.08726811e+00 0.23353955 0.89628012 834.50 4.96882071e+00 1.39672319e+00 5.16139660e+00 0.27402614 0.84405767 834.75 5.62251790e+00 7.98044484e-01 5.67887159e+00 0.14099540 0.87811254 835.00 5.93798595e+00 5.21693423e-01 5.96085910e+00 0.08763195 0.94463243 835.25 6.01050837e+00 -1.67366049e-02 6.01053167e+00 -0.00278455 0.92586692 835.50 6.14337392e+00 -5.11887053e-01 6.16466312e+00 -0.08313141 0.93057671 835.75 5.95515638e+00 -1.14743506e+00 6.06469247e+00 -0.19034657 0.92694949 836.00 5.97146011e+00 -1.55819420e+00 6.17141029e+00 -0.25524856 0.92361735 836.25 5.69899995e+00 -2.29829893e+00 6.14497993e+00 -0.38333170 0.91988507 836.50 5.47698156e+00 -2.96175859e+00 6.22650311e+00 -0.49572517 0.93910818 836.75 4.85417050e+00 -3.29745690e+00 5.86823596e+00 -0.59670050 0.92029788 837.00 4.35581810e+00 -3.64842938e+00 5.68191766e+00 -0.69725051 0.93399974 837.25 3.48655772e+00 -3.73948272e+00 5.11271119e+00 -0.82038576 0.93789906 837.50 3.03404891e+00 -3.65454389e+00 4.74985725e+00 -0.87790254 0.94365089 837.75 2.64734610e+00 -3.19525010e+00 4.14946557e+00 -0.87890219 0.92516874 838.00 2.59348298e+00 -2.99486490e+00 3.96173822e+00 -0.85709983 0.92516706 838.25 2.40714185e+00 -3.07386380e+00 3.90422470e+00 -0.90644573 0.94059952 838.50 2.28789972e+00 -2.90567879e+00 3.69830425e+00 -0.90379242 0.92145816 838.75 2.23761862e+00 -2.43437504e+00 3.30652671e+00 -0.82748731 0.92124476 839.00 2.15753621e+00 -2.38956010e+00 3.21946579e+00 -0.83638077 0.91708952 839.25 2.03381638e+00 -2.30470736e+00 3.07377375e+00 -0.84775573 0.91527216 839.50 2.12958953e+00 -2.41330593e+00 3.21857066e+00 -0.84776993 0.91080163 839.75 2.16658738e+00 -2.50116102e+00 3.30906442e+00 -0.85695352 0.90119259 840.00 1.87868460e+00 -2.58867400e+00 3.19854482e+00 -0.94300823 0.90463795 840.25 1.51816092e+00 -2.45575831e+00 2.88713724e+00 -1.01709857 0.86702266 840.50 1.20523413e+00 -2.31609731e+00 2.61091862e+00 -1.09098360 0.82915283 840.75 9.85962415e-01 -1.92430401e+00 2.16219051e+00 -1.09729897 0.67527672 841.00 1.24802918e+00 -1.57659934e+00 2.01078152e+00 -0.90120104 0.58302700 841.25 1.59019985e+00 -1.26197998e+00 2.03010567e+00 -0.67082529 0.70644306 841.50 1.90971211e+00 -1.35032350e+00 2.33888305e+00 -0.61546334 0.74206061 841.75 2.53005219e+00 -1.42287954e+00 2.90271429e+00 -0.51230694 0.83315213 842.00 2.77727609e+00 -1.73962291e+00 3.27712532e+00 -0.55958917 0.83624045 842.25 3.06150761e+00 -2.18683320e+00 3.76232219e+00 -0.62025858 0.85016595 842.50 3.35434099e+00 -2.94232512e+00 4.46193686e+00 -0.72005734 0.88086312 842.75 3.26376163e+00 -3.73974165e+00 4.96364861e+00 -0.85325694 0.91988761 843.00 2.85935419e+00 -4.02458176e+00 4.93691855e+00 -0.95307644 0.90520908 843.25 2.44101952e+00 -4.25047531e+00 4.90154227e+00 -1.04949331 0.90602766 843.50 1.71921987e+00 -4.52338496e+00 4.83908344e+00 -1.20758488 0.86169431 843.75 6.06135680e-01 -5.16885196e+00 5.20427046e+00 -1.45406248 0.88885660 844.00 1.32174074e-01 -5.12819455e+00 5.12989759e+00 -1.54502803 0.90065721 844.25 -2.55501820e-01 -5.11600410e+00 5.12238023e+00 -1.62069654 0.90719478 844.50 -8.95675261e-01 -4.51458559e+00 4.60257724e+00 -1.76664901 0.89962366 844.75 -1.28056484e+00 -4.40241374e+00 4.58487656e+00 -1.85386335 0.94326696 845.00 -1.70049900e+00 -3.85285573e+00 4.21143612e+00 -1.98644260 0.93221743 845.25 -1.91509182e+00 -3.51884785e+00 4.00622851e+00 -2.06920522 0.93881581 845.50 -2.06689111e+00 -3.18805204e+00 3.79943610e+00 -2.14599254 0.91040333 845.75 -2.16643614e+00 -2.87343962e+00 3.59862485e+00 -2.21682205 0.90724485 846.00 -2.28285962e+00 -2.54494352e+00 3.41879885e+00 -2.30196136 0.88821040 846.25 -2.35129829e+00 -2.18994677e+00 3.21317141e+00 -2.39170979 0.86889677 846.50 -2.27643966e+00 -1.75145966e+00 2.87224450e+00 -2.48579983 0.80982968 846.75 -2.34547454e+00 -1.57836563e+00 2.82709902e+00 -2.54925895 0.78497074 847.00 -2.21393119e+00 -1.43192539e+00 2.63664591e+00 -2.56748471 0.80867570 847.25 -2.19709884e+00 -1.30201635e+00 2.55391658e+00 -2.60662685 0.83386548 847.50 -1.97846772e+00 -1.19875303e+00 2.31329708e+00 -2.59684642 0.74540984 847.75 -1.99463863e+00 -9.49461289e-01 2.20908578e+00 -2.69732329 0.77326962 848.00 -2.04563472e+00 -7.20847820e-01 2.16892669e+00 -2.80279607 0.74379624 848.25 -1.96998973e+00 -6.47083668e-01 2.07354210e+00 -2.82422494 0.68640645 848.50 -1.86193037e+00 -4.02528341e-01 1.90494456e+00 -2.92868057 0.68923393 848.75 -1.73194043e+00 -3.15533144e-01 1.76044847e+00 -2.96138433 0.70431152 849.00 -1.52179809e+00 -2.45300773e-01 1.54144150e+00 -2.98177594 0.58952118 849.25 -1.52596921e+00 -2.39924933e-01 1.54471551e+00 -2.98564146 0.59087819 849.50 -1.72909599e+00 -2.68866298e-02 1.72930501e+00 -3.12604438 0.61496069 849.75 -1.63190867e+00 9.89464669e-02 1.63490560e+00 3.08103444 0.61016986 850.00 -1.30202040e+00 1.83805150e-01 1.31493021e+00 3.00135019 0.54778073 850.25 -1.12282225e+00 3.12013498e-01 1.16536785e+00 2.87054789 0.47509726 850.50 -1.14311636e+00 2.56605219e-01 1.17156359e+00 2.92077449 0.48985424 850.75 -1.03124521e+00 2.24768812e-01 1.05545616e+00 2.92699029 0.44586928 851.00 -1.01095372e+00 2.75320791e-01 1.04777333e+00 2.87570326 0.59175328 851.25 -1.12384965e+00 3.29773695e-01 1.17123385e+00 2.85617219 0.62042562 851.50 -1.26042631e+00 4.58278049e-01 1.34115371e+00 2.79286285 0.71103787 851.75 -1.22992625e+00 4.31542859e-01 1.30343693e+00 2.80414398 0.66709439 852.00 -1.33625411e+00 3.29742599e-01 1.37633761e+00 2.89965970 0.73507774 852.25 -1.46006099e+00 3.63020487e-01 1.50451387e+00 2.89790025 0.69598344 852.50 -1.61908143e+00 5.23047300e-01 1.70147088e+00 2.82912377 0.76464048 852.75 -1.75968356e+00 6.27587656e-01 1.86824851e+00 2.79900764 0.81212318 853.00 -1.93289172e+00 8.17622687e-01 2.09870847e+00 2.74141308 0.89745142 853.25 -2.10933208e+00 1.15332033e+00 2.40404442e+00 2.64123237 0.89045293 853.50 -2.32654930e+00 1.62360205e+00 2.83706103e+00 2.53230543 0.92432473 853.75 -1.92160635e+00 2.06412220e+00 2.82013677e+00 2.32045318 0.91151042 854.00 -1.55619941e+00 2.42635695e+00 2.88252747e+00 2.14108282 0.95027299 854.25 -1.16573845e+00 2.65590529e+00 2.90047910e+00 1.98440070 0.94130464 854.50 -8.80107001e-01 2.87328259e+00 3.00505261e+00 1.86802941 0.95873289 854.75 -5.22590019e-01 2.84099374e+00 2.88865812e+00 1.75270898 0.94782077 855.00 -1.48622234e-01 2.76891069e+00 2.77289649e+00 1.62442021 0.95839674 855.25 7.97110880e-02 2.52125233e+00 2.52251208e+00 1.53919118 0.95434410 855.50 1.84395767e-01 2.39733861e+00 2.40441972e+00 1.49403061 0.95784443 855.75 2.62997783e-01 2.36867085e+00 2.38322669e+00 1.46021745 0.95409699 856.00 2.70456679e-01 2.36499133e+00 2.38040560e+00 1.45693255 0.95121810 856.25 3.96739866e-01 2.43231860e+00 2.46446268e+00 1.40910842 0.95376633 856.50 4.47847140e-01 2.45742979e+00 2.49790477e+00 1.39053251 0.95142943 856.75 4.94115821e-01 2.49032662e+00 2.53887320e+00 1.37492617 0.94673330 857.00 6.65657606e-01 2.36153935e+00 2.45356234e+00 1.29605029 0.95018601 857.25 8.71339252e-01 2.33388372e+00 2.49123369e+00 1.21347912 0.94468041 857.50 9.86831250e-01 2.31197100e+00 2.51377124e+00 1.16737204 0.93975494 857.75 1.09739565e+00 2.11125994e+00 2.37943181e+00 1.09144838 0.94962636 858.00 1.10405654e+00 2.01396604e+00 2.29673683e+00 1.06933599 0.94212115 858.25 9.35514196e-01 2.05425390e+00 2.25724299e+00 1.14345803 0.92236661 858.50 8.72234899e-01 1.97009942e+00 2.15454994e+00 1.15399913 0.90804290 858.75 8.30717806e-01 1.92772786e+00 2.09910142e+00 1.16391276 0.90165070 859.00 9.12334281e-01 2.02444314e+00 2.22052334e+00 1.14739420 0.91836730 859.25 7.84445100e-01 2.21562484e+00 2.35039306e+00 1.23051680 0.91235301 859.50 7.88900388e-01 2.20070364e+00 2.33783240e+00 1.22659017 0.91708345 859.75 1.10736183e+00 2.23623044e+00 2.49539111e+00 1.11100308 0.90477420 860.00 1.20727534e+00 2.17309587e+00 2.48593230e+00 1.06369787 0.90385744 860.25 1.40303797e+00 2.08083301e+00 2.50965766e+00 0.97755008 0.90737148 860.50 1.39866698e+00 1.97227570e+00 2.41787939e+00 0.95394645 0.89308584 860.75 1.29551753e+00 1.85637574e+00 2.26373509e+00 0.96149821 0.86343324 861.00 1.11720480e+00 1.87675611e+00 2.18411540e+00 1.03385094 0.85571912 861.25 8.14710406e-01 1.72161120e+00 1.90465172e+00 1.12879678 0.87873103 861.50 6.44293844e-01 1.78668620e+00 1.89930570e+00 1.22470236 0.84748966 861.75 3.22662995e-01 2.21737847e+00 2.24073173e+00 1.42629503 0.86752326 862.00 3.81577502e-01 2.47633152e+00 2.50555766e+00 1.41790897 0.86335012 862.25 2.74037455e-01 3.22820007e+00 3.23981052e+00 1.48611073 0.88951445 862.50 5.21571922e-01 3.53310669e+00 3.57139750e+00 1.42423074 0.87256499 862.75 7.78258827e-01 3.97219741e+00 4.04772023e+00 1.37732062 0.85095647 863.00 8.85942815e-01 4.21781373e+00 4.30985467e+00 1.36375828 0.79170596 863.25 2.21427605e+00 4.10334460e+00 4.66266612e+00 1.07595180 0.76901937 863.50 2.94947469e+00 4.24585226e+00 5.16978358e+00 0.96365516 0.80797255 863.75 3.48221513e+00 4.60544728e+00 5.77373076e+00 0.92339760 0.86473597 864.00 3.93589207e+00 4.39931699e+00 5.90298538e+00 0.84093946 0.86084270 864.25 3.84238241e+00 4.32581108e+00 5.78589181e+00 0.84451349 0.85695389 864.50 3.85953844e+00 3.76014971e+00 5.38839149e+00 0.77235523 0.83884737 864.75 4.30802959e+00 3.25429592e+00 5.39903333e+00 0.64694969 0.86734646 865.00 4.62165030e+00 3.00420235e+00 5.51224847e+00 0.57639494 0.86178116 865.25 4.87726324e+00 2.79517072e+00 5.62144786e+00 0.52040693 0.84761571 865.50 5.26125163e+00 2.44089416e+00 5.79989078e+00 0.43438406 0.90404028 865.75 5.24139744e+00 2.30903244e+00 5.72746697e+00 0.41495715 0.92717401 866.00 5.41221793e+00 2.22641047e+00 5.85226507e+00 0.39026736 0.91147030 866.25 5.53133932e+00 1.94755888e+00 5.86418795e+00 0.33854028 0.88999035 866.50 4.95764226e+00 1.62723528e+00 5.21786465e+00 0.31714843 0.79095719 866.75 5.09709211e+00 1.85260937e+00 5.42333011e+00 0.34861874 0.77073673 867.00 5.48472109e+00 1.86768230e+00 5.79399712e+00 0.32820865 0.79768350 867.25 5.57587306e+00 1.25338825e+00 5.71501028e+00 0.22111246 0.79104138 867.50 5.31020269e+00 -3.98451904e-01 5.32513066e+00 -0.07489481 0.71698534 867.75 4.93270966e+00 -8.76840791e-01 5.01003736e+00 -0.17592285 0.70194063 868.00 4.52705711e+00 -5.65110079e-01 4.56219196e+00 -0.12418707 0.70825886 868.25 4.36158568e+00 -3.63170224e-01 4.37667936e+00 -0.08307401 0.76700520 868.50 3.90741816e+00 -5.63993133e-02 3.90782517e+00 -0.01443291 0.78952996 868.75 4.20121488e+00 2.92739580e-01 4.21140154e+00 0.06956730 0.77239242 869.00 4.58160868e+00 -9.13331563e-02 4.58251894e+00 -0.01993210 0.77966613 869.25 4.11978245e+00 3.01674346e-02 4.11989290e+00 0.00732245 0.62896973 869.50 3.44484416e+00 -1.76826487e-01 3.44937949e+00 -0.05128575 0.51560363 869.75 3.46632487e+00 -9.50802974e-01 3.59436147e+00 -0.26771264 0.55522309 870.00 2.77042751e+00 -1.06823422e+00 2.96924114e+00 -0.36801789 0.53412211 870.25 2.07300432e+00 -1.09298608e+00 2.34349429e+00 -0.48520715 0.43630315 870.50 1.53077210e+00 -1.05581195e+00 1.85957041e+00 -0.60379672 0.38207351 870.75 1.47909333e+00 -6.18946934e-01 1.60337531e+00 -0.39632138 0.27736966 871.00 2.10517585e+00 2.51253360e-01 2.12011642e+00 0.11878840 0.43104461 871.25 2.21622193e+00 3.25502891e-01 2.23999816e+00 0.14583024 0.57503213 871.50 2.73817546e+00 1.10783800e+00 2.95379584e+00 0.38445687 0.74588392 871.75 2.90080767e+00 1.48469924e+00 3.25868332e+00 0.47306098 0.71648971 872.00 3.20637967e+00 1.98717306e+00 3.77223108e+00 0.55481946 0.71366112 872.25 3.41221144e+00 1.98649553e+00 3.94833527e+00 0.52720787 0.78214477 872.50 3.72422966e+00 2.00233323e+00 4.22838325e+00 0.49331227 0.80100256 872.75 4.52508159e+00 2.12123842e+00 4.99760101e+00 0.43835584 0.78619952 873.00 5.48991911e+00 1.99063673e+00 5.83967862e+00 0.34785409 0.79541133 873.25 5.99236796e+00 1.34020306e+00 6.14040862e+00 0.22003071 0.81584720 873.50 5.89113924e+00 5.51454010e-01 5.91689302e+00 0.09333539 0.79218648 873.75 6.13921320e+00 4.53178104e-01 6.15591659e+00 0.07368333 0.82025162 874.00 6.94280963e+00 8.45359157e-02 6.94332427e+00 0.01217544 0.84802475 874.25 6.57106707e+00 -4.02760813e-01 6.58339872e+00 -0.06121648 0.82840622 874.50 5.59816251e+00 -9.82848698e-01 5.68378528e+00 -0.17379509 0.82238172 874.75 5.51840094e+00 -8.78617931e-01 5.58790823e+00 -0.15789077 0.85996850 875.00 5.61256172e+00 -8.23639709e-01 5.67267410e+00 -0.14570931 0.90786011 875.25 5.65847028e+00 -8.70880975e-01 5.72509560e+00 -0.15270925 0.85806681 875.50 5.95542669e+00 -1.11833073e+00 6.05951901e+00 -0.18562179 0.85976015 875.75 5.43074579e+00 -8.62473146e-01 5.49880530e+00 -0.15749770 0.85849948 876.00 5.24621185e+00 -8.45575223e-01 5.31391911e+00 -0.15980389 0.88286237 876.25 5.28542064e+00 -1.23502894e+00 5.42779585e+00 -0.22954845 0.91022923 876.50 5.27406900e+00 -1.39345217e+00 5.45504471e+00 -0.25830572 0.92323136 876.75 5.16423440e+00 -9.46219079e-01 5.25020452e+00 -0.18121538 0.89627646 877.00 5.00917784e+00 -7.63798421e-01 5.06707516e+00 -0.15131429 0.87961856 877.25 4.63327720e+00 -2.78490381e-01 4.64163921e+00 -0.06003434 0.83406147 877.50 4.55550300e+00 -2.69778836e-01 4.56348422e+00 -0.05915134 0.83993291 877.75 4.31684213e+00 -3.51245706e-01 4.33110835e+00 -0.08118750 0.84524212 878.00 4.01385662e+00 -2.10425216e-01 4.01936857e+00 -0.05237675 0.84391374 878.25 3.92370755e+00 4.59881984e-02 3.92397705e+00 0.01172006 0.87684945 878.50 3.83749136e+00 1.98394471e-01 3.84261634e+00 0.05165301 0.91254906 878.75 3.48969908e+00 4.57350206e-01 3.51954100e+00 0.13031450 0.93436080 879.00 3.23849476e+00 4.08648973e-01 3.26417559e+00 0.12552144 0.92192416 879.25 2.79795040e+00 6.40767169e-01 2.87038482e+00 0.22513083 0.91583781 879.50 2.59978570e+00 8.11373286e-01 2.72345595e+00 0.30251346 0.92999385 879.75 2.15421859e+00 8.21011793e-01 2.30536724e+00 0.36412370 0.91608233 880.00 1.94539638e+00 7.50276691e-01 2.08506167e+00 0.36809028 0.89619264 880.25 1.59891897e+00 7.02206341e-01 1.74632059e+00 0.41381606 0.94327606 880.50 1.45473497e+00 6.72039024e-01 1.60246382e+00 0.43276070 0.95239125 880.75 1.24553694e+00 5.60954427e-01 1.36602787e+00 0.42316288 0.95912340 881.00 1.15677895e+00 5.38476042e-01 1.27596786e+00 0.43566546 0.96277919 881.25 1.03127446e+00 4.74806310e-01 1.13532729e+00 0.43147487 0.95832336 881.50 9.91032172e-01 4.08121388e-01 1.07177788e+00 0.39064959 0.93856204 881.75 9.12694141e-01 2.53335423e-01 9.47200840e-01 0.27075284 0.95005408 882.00 9.16981176e-01 2.19246733e-01 9.42827453e-01 0.23469025 0.95390772 882.25 8.79358137e-01 1.60751245e-01 8.93930476e-01 0.18080877 0.91496884 882.50 8.50579430e-01 1.19921378e-01 8.58991562e-01 0.14006468 0.91311006 882.75 8.75808301e-01 9.33549044e-02 8.80769730e-01 0.10619188 0.93877381 883.00 8.86007019e-01 7.26935168e-02 8.88984131e-01 0.08186285 0.92415208 883.25 8.70198471e-01 2.99334220e-02 8.70713150e-01 0.03438483 0.91741163 883.50 9.25874728e-01 6.77445336e-02 9.28349791e-01 0.07303799 0.92285402 883.75 9.78587298e-01 1.03686427e-01 9.84065026e-01 0.10556136 0.92794256 884.00 1.00884981e+00 5.91096238e-02 1.01057997e+00 0.05852420 0.92192833 884.25 1.00678770e+00 5.50543446e-02 1.00829185e+00 0.05462876 0.93924309 884.50 1.06098769e+00 5.83874517e-02 1.06259305e+00 0.05497577 0.93364956 884.75 1.11069292e+00 -5.78530481e-03 1.11070799e+00 -0.00520869 0.93130442 885.00 1.15992532e+00 -2.69057500e-02 1.16023733e+00 -0.02319195 0.92901344 885.25 1.23358666e+00 -2.77921050e-02 1.23389969e+00 -0.02252570 0.92969004 885.50 1.28455004e+00 -3.77486357e-02 1.28510457e+00 -0.02937821 0.92887077 885.75 1.24593353e+00 -7.54880415e-02 1.24821825e+00 -0.06051356 0.92363321 886.00 1.29392081e+00 -1.52797835e-01 1.30291145e+00 -0.11754464 0.94068843 886.25 1.30669514e+00 -2.03395466e-01 1.32243030e+00 -0.15441724 0.96918795 886.50 1.25801360e+00 -2.20240470e-01 1.27714685e+00 -0.17331361 0.97927665 886.75 1.21597564e+00 -2.42816771e-01 1.23998255e+00 -0.19709635 0.98569389 887.00 1.12270928e+00 -2.63713437e-01 1.15326532e+00 -0.23070793 0.98398138 887.25 1.07071066e+00 -2.58574122e-01 1.10149076e+00 -0.23696059 0.98809906 887.50 1.01406575e+00 -2.68785214e-01 1.04908285e+00 -0.25909898 0.98465990 887.75 9.82238040e-01 -2.70910871e-01 1.01891328e+00 -0.26911891 0.98321733 888.00 9.04110179e-01 -2.62788639e-01 9.41526996e-01 -0.28286609 0.95806357 888.25 8.93441261e-01 -2.35991352e-01 9.24082900e-01 -0.25823966 0.95711858 888.50 8.31547617e-01 -2.33369946e-01 8.63674111e-01 -0.27360701 0.95651376 888.75 8.13655627e-01 -2.19597246e-01 8.42768313e-01 -0.26360899 0.95988041 889.00 8.05031042e-01 -2.36195771e-01 8.38965685e-01 -0.28539042 0.95939779 889.25 7.92218263e-01 -2.57936854e-01 8.33151365e-01 -0.31476374 0.94420341 889.50 7.02632615e-01 -2.55803112e-01 7.47748503e-01 -0.34914848 0.94586809 889.75 6.66290640e-01 -2.58496824e-01 7.14677427e-01 -0.37008770 0.95035884 890.00 6.15704867e-01 -2.38531630e-01 6.60295253e-01 -0.36960802 0.93758002 890.25 6.19744321e-01 -2.45323437e-01 6.66533279e-01 -0.37692040 0.94417901 890.50 6.12961386e-01 -2.46359377e-01 6.60616836e-01 -0.38215756 0.94322076 890.75 6.01160153e-01 -2.48079644e-01 6.50336097e-01 -0.39137926 0.94611507 891.00 5.82182629e-01 -2.49360128e-01 6.33338051e-01 -0.40467887 0.93957685 891.25 5.65639811e-01 -2.68189818e-01 6.25998542e-01 -0.44274261 0.94127351 891.50 5.68335604e-01 -3.10554467e-01 6.47649161e-01 -0.50009663 0.95257867 891.75 5.77260110e-01 -2.98589138e-01 6.49911308e-01 -0.47735402 0.94627334 892.00 5.95189357e-01 -3.24145235e-01 6.77731882e-01 -0.49869451 0.94366696 892.25 6.23684173e-01 -3.61832746e-01 7.21044301e-01 -0.52569888 0.95539609 892.50 6.28878219e-01 -3.83713921e-01 7.36698166e-01 -0.54785382 0.97179984 892.75 6.38906056e-01 -4.00359493e-01 7.53981878e-01 -0.55977261 0.97323494 893.00 6.68931656e-01 -3.78098601e-01 7.68393202e-01 -0.51445901 0.98007399 893.25 6.73015961e-01 -3.80206750e-01 7.72986194e-01 -0.51423330 0.98200525 893.50 6.81666582e-01 -3.98138665e-01 7.89419866e-01 -0.52862136 0.97550862 893.75 7.05772081e-01 -4.04705675e-01 8.13572931e-01 -0.52064803 0.96374448 894.00 7.24539906e-01 -4.12816900e-01 8.33892001e-01 -0.51789054 0.93996164 894.25 7.74624901e-01 -4.14733768e-01 8.78662527e-01 -0.49156454 0.91899473 894.50 8.52122018e-01 -4.55595573e-01 9.66270800e-01 -0.49098964 0.92166987 894.75 8.48338776e-01 -4.66012062e-01 9.67908012e-01 -0.50232335 0.90100912 895.00 9.27762578e-01 -4.93930783e-01 1.05105234e+00 -0.48922199 0.88677822 895.25 9.27004591e-01 -4.62394447e-01 1.03592767e+00 -0.46269108 0.85436312 895.50 8.84153530e-01 -4.67753859e-01 1.00026053e+00 -0.48660994 0.80243679 895.75 9.41424052e-01 -5.01835271e-01 1.06682608e+00 -0.48974431 0.80840348 896.00 1.05849893e+00 -5.10084453e-01 1.17499197e+00 -0.44905831 0.79381583 896.25 1.15181386e+00 -5.55441073e-01 1.27874547e+00 -0.44933214 0.75130498 896.50 1.06370058e+00 -5.55977347e-01 1.20023737e+00 -0.48162827 0.67390109 896.75 9.78543655e-01 -4.55994302e-01 1.07957329e+00 -0.43607366 0.58333173 897.00 9.51231476e-01 -4.72393375e-01 1.06207195e+00 -0.46093388 0.47404918 897.25 1.10680676e+00 -3.88126324e-01 1.17288672e+00 -0.33727350 0.47600914 897.50 9.77072425e-01 -4.12973605e-01 1.06076280e+00 -0.39989060 0.51506134 897.75 8.57968933e-01 -4.56955341e-01 9.72069377e-01 -0.48938721 0.52311177 898.00 8.29848468e-01 -5.73825410e-01 1.00892224e+00 -0.60498639 0.55367703 898.25 8.97697445e-01 -6.12033586e-01 1.08648323e+00 -0.59839391 0.61299905 898.50 8.54605568e-01 -4.64913874e-01 9.72880048e-01 -0.49823264 0.56564428 898.75 6.53162969e-01 -4.20122896e-01 7.76611300e-01 -0.57158922 0.37532159 899.00 4.99304281e-01 -5.04906423e-01 7.10095248e-01 -0.79097676 0.41312027 899.25 3.58401672e-01 -6.07127680e-01 7.05021828e-01 -1.03752236 0.40362580 899.50 4.47126033e-01 -6.32107795e-01 7.74262199e-01 -0.95514966 0.50969248 899.75 5.50537780e-01 -6.05820940e-01 8.18602992e-01 -0.83316976 0.57337718 900.00 5.68854285e-01 -5.73562013e-01 8.07817170e-01 -0.78951899 0.51546630 900.25 6.12680144e-01 -6.60469315e-01 9.00886605e-01 -0.82291673 0.63987111 900.50 5.80904630e-01 -8.38174296e-01 1.01979720e+00 -0.96474364 0.72767802 900.75 6.02637620e-01 -8.52186337e-01 1.04374022e+00 -0.95527681 0.69087898 901.00 6.68134816e-01 -7.86780334e-01 1.03219544e+00 -0.86676618 0.72453556 901.25 6.32513423e-01 -7.88080492e-01 1.01051675e+00 -0.89447201 0.76636625 901.50 5.60488891e-01 -7.68634002e-01 9.51286511e-01 -0.94073983 0.65574716 901.75 5.00712255e-01 -9.01330953e-01 1.03107238e+00 -1.06372085 0.62574579 902.00 5.85065071e-01 -9.96429419e-01 1.15549674e+00 -1.03987033 0.72730626 902.25 6.91337216e-01 -1.06333918e+00 1.26832068e+00 -0.99431087 0.81531002 902.50 7.26842777e-01 -1.10037782e+00 1.31876145e+00 -0.98704776 0.86354873 902.75 6.87824674e-01 -1.10009644e+00 1.29742628e+00 -1.01202420 0.86489041 903.00 7.22912683e-01 -1.14963507e+00 1.35803665e+00 -1.00945529 0.85695542 903.25 7.73111983e-01 -1.24337477e+00 1.46413215e+00 -1.01451214 0.89680061 903.50 8.74504383e-01 -1.28610841e+00 1.55525971e+00 -0.97364590 0.93232383 903.75 9.08288363e-01 -1.31966142e+00 1.60202809e+00 -0.96798373 0.94179000 904.00 9.02808279e-01 -1.30746390e+00 1.58887528e+00 -0.96647239 0.93716443 904.25 9.83571796e-01 -1.24783436e+00 1.58886880e+00 -0.90327782 0.95012768 904.50 1.05392409e+00 -1.29515653e+00 1.66978634e+00 -0.88773172 0.96074507 904.75 1.12454853e+00 -1.33746625e+00 1.74740533e+00 -0.87166462 0.97206949 905.00 1.20513727e+00 -1.31612411e+00 1.78452753e+00 -0.82939013 0.97749115 905.25 1.24759100e+00 -1.28521685e+00 1.79116321e+00 -0.80025246 0.98726580 905.50 1.30117236e+00 -1.22509992e+00 1.78715397e+00 -0.75529473 0.98454635 905.75 1.39795224e+00 -1.17546826e+00 1.82647094e+00 -0.69915802 0.98192451 906.00 1.35341181e+00 -1.08249583e+00 1.73306686e+00 -0.67463568 0.96199180 906.25 1.43781084e+00 -9.24563784e-01 1.70942043e+00 -0.57146385 0.94091517 906.50 1.58721618e+00 -8.60193747e-01 1.80532227e+00 -0.49664273 0.96899992 906.75 1.66977558e+00 -7.89933588e-01 1.84719938e+00 -0.44187874 0.96907424 907.00 1.73269675e+00 -7.29003185e-01 1.87980948e+00 -0.39825115 0.95532987 907.25 1.81187304e+00 -6.83428561e-01 1.93648096e+00 -0.36069323 0.95420155 907.50 1.82069498e+00 -5.69864025e-01 1.90779329e+00 -0.30333356 0.88759315 907.75 1.86888033e+00 -4.33360893e-01 1.91846693e+00 -0.22785570 0.88081012 908.00 2.03011516e+00 -4.38406389e-01 2.07691303e+00 -0.21268543 0.91922698 908.25 2.15868963e+00 -3.99684546e-01 2.19537893e+00 -0.18307821 0.91799004 908.50 2.10588643e+00 -4.31393108e-01 2.14961803e+00 -0.20205568 0.89164296 908.75 1.99106947e+00 -3.41668304e-01 2.02017199e+00 -0.16994519 0.87510881 909.00 2.01914579e+00 -4.97786299e-02 2.01975930e+00 -0.02464832 0.85854633 909.25 2.03794687e+00 -4.67641378e-02 2.03848334e+00 -0.02294267 0.87533458 909.50 2.01369303e+00 -1.92269754e-01 2.02285127e+00 -0.09519258 0.87740469 909.75 2.05355771e+00 -1.65507006e-01 2.06021646e+00 -0.08042143 0.86814609 910.00 2.17421678e+00 -1.03779952e-01 2.17669219e+00 -0.04769591 0.87197837 910.25 2.01296027e+00 -5.62061251e-02 2.01374482e+00 -0.02791487 0.87200119 910.50 1.71610378e+00 1.02379344e-01 1.71915494e+00 0.05958739 0.82745921 910.75 1.66346893e+00 2.15444022e-01 1.67736252e+00 0.12879794 0.77439619 911.00 1.40587802e+00 2.56875530e-01 1.42915291e+00 0.18072185 0.61580353 911.25 1.38350432e+00 3.59368522e-01 1.42941594e+00 0.25413609 0.54487060 911.50 1.45387430e+00 3.82583704e-01 1.50336981e+00 0.25731420 0.46293726 911.75 1.48771440e+00 6.48213018e-01 1.62279828e+00 0.41090758 0.51756926 912.00 2.01845420e+00 9.83108133e-01 2.24514119e+00 0.45324206 0.60276347 912.25 2.21253828e+00 1.16812264e+00 2.50196646e+00 0.48576140 0.67552629 912.50 2.04769535e+00 1.49649194e+00 2.53624612e+00 0.63111096 0.74289195 912.75 2.02912624e+00 1.37212381e+00 2.44950547e+00 0.59458328 0.72158693 913.00 1.69356059e+00 1.12286495e+00 2.03198749e+00 0.58547390 0.76744286 913.25 1.68684938e+00 1.20578677e+00 2.07349526e+00 0.62060047 0.81516184 913.50 1.75809952e+00 1.30579224e+00 2.18997883e+00 0.63883167 0.87477038 913.75 1.67553541e+00 1.39423612e+00 2.17975074e+00 0.69401811 0.85165232 914.00 1.56297807e+00 1.61753549e+00 2.24929355e+00 0.80255013 0.84367159 914.25 1.68144521e+00 1.59402933e+00 2.31693494e+00 0.75871649 0.82518769 914.50 1.86743079e+00 1.44749634e+00 2.36274066e+00 0.65938951 0.82996542 914.75 1.91958009e+00 1.32656993e+00 2.33336142e+00 0.60470951 0.85977971 915.00 1.91349311e+00 1.27843639e+00 2.30127258e+00 0.58900569 0.86198757 915.25 1.94298339e+00 1.04383354e+00 2.20562302e+00 0.49298798 0.85429888 915.50 2.09109069e+00 8.17938005e-01 2.24536920e+00 0.37285713 0.91092001 915.75 1.96275237e+00 5.13395287e-01 2.02878574e+00 0.25583720 0.89632741 916.00 1.90143589e+00 2.03919050e-01 1.91233925e+00 0.10683643 0.92797017 916.25 1.83682087e+00 4.88152446e-02 1.83746941e+00 0.02656969 0.91010492 916.50 1.86361789e+00 -1.76482367e-01 1.87195557e+00 -0.09441723 0.86888216 916.75 1.72521984e+00 -4.66837364e-01 1.78726624e+00 -0.26426713 0.85992966 917.00 1.72691590e+00 -6.41946666e-01 1.84237185e+00 -0.35590085 0.89262196 917.25 1.51783178e+00 -9.59812318e-01 1.79584326e+00 -0.56387262 0.88009978 917.50 1.49814674e+00 -1.21897118e+00 1.93140736e+00 -0.68301051 0.89440185 917.75 1.30781183e+00 -1.49125287e+00 1.98348352e+00 -0.85084112 0.91627868 918.00 1.09274155e+00 -1.58553564e+00 1.92561870e+00 -0.96735963 0.92240670 918.25 9.75085781e-01 -1.79488590e+00 2.04264723e+00 -1.07314420 0.94989364 918.50 8.80101537e-01 -1.87407353e+00 2.07044206e+00 -1.13174711 0.93499105 918.75 6.04932311e-01 -2.00714834e+00 2.09632716e+00 -1.27806576 0.88415274 919.00 4.92181797e-01 -2.03050286e+00 2.08930246e+00 -1.33298892 0.89381282 919.25 4.53840148e-01 -2.05759105e+00 2.10704813e+00 -1.35370366 0.86830707 919.50 3.26376524e-01 -2.03484270e+00 2.06085091e+00 -1.41175694 0.86374021 919.75 2.69525509e-01 -1.98026200e+00 1.99851985e+00 -1.43552157 0.79697561 920.00 2.50528023e-01 -1.98870443e+00 2.00442251e+00 -1.44548096 0.78299164 920.25 -2.25467663e-02 -2.12946503e+00 2.12958439e+00 -1.58138393 0.75372371 920.50 -8.97603568e-02 -2.00712012e+00 2.00912620e+00 -1.61548752 0.72746334 920.75 -2.24259050e-01 -2.00147515e+00 2.01399972e+00 -1.68237781 0.73232216 921.00 -2.50843834e-01 -1.92772204e+00 1.94397399e+00 -1.70019374 0.73024344 921.25 -1.24460249e-01 -1.55335303e+00 1.55833115e+00 -1.65074913 0.62623688 921.50 -4.66737796e-02 -1.49683530e+00 1.49756280e+00 -1.60196787 0.66250068 921.75 1.21938072e-01 -1.66570612e+00 1.67016339e+00 -1.49772164 0.70852138 922.00 4.09750783e-01 -1.56419611e+00 1.61697408e+00 -1.31459686 0.67808186 922.25 4.16115724e-01 -1.40325209e+00 1.46364911e+00 -1.28251991 0.65600802 922.50 4.94450880e-01 -1.57047021e+00 1.64646845e+00 -1.26577873 0.68564240 922.75 7.16069393e-01 -1.68314124e+00 1.82913089e+00 -1.16855618 0.72885076 923.00 7.67295193e-01 -1.75784053e+00 1.91800554e+00 -1.15922659 0.74653875 923.25 9.75538802e-01 -1.87106738e+00 2.11011116e+00 -1.09019067 0.81225312 923.50 1.02344559e+00 -1.87642906e+00 2.13738786e+00 -1.07147473 0.83073433 923.75 1.28573821e+00 -1.75453696e+00 2.17520635e+00 -0.93838938 0.77603345 924.00 1.50185864e+00 -1.61269650e+00 2.20371717e+00 -0.82097021 0.76487894 924.25 1.63161269e+00 -1.81287352e+00 2.43898962e+00 -0.83797314 0.73924894 924.50 1.85618160e+00 -1.81988515e+00 2.59949843e+00 -0.77552477 0.70895335 924.75 2.08878713e+00 -1.50996126e+00 2.57740464e+00 -0.62592312 0.75959237 925.00 2.12882169e+00 -1.42598716e+00 2.56228826e+00 -0.59020190 0.72696710 925.25 2.05202271e+00 -1.44512211e+00 2.50981575e+00 -0.61356777 0.67146460 925.50 1.84947928e+00 -1.13235438e+00 2.16859403e+00 -0.54938240 0.62947254 925.75 1.86605364e+00 -7.48024703e-01 2.01039726e+00 -0.38124682 0.57659488 926.00 1.98929422e+00 -7.75397221e-01 2.13507197e+00 -0.37166952 0.46609415 926.25 2.10216984e+00 -1.27289518e+00 2.45751504e+00 -0.54446472 0.46122823 926.50 2.23625151e+00 -8.58435746e-01 2.39535650e+00 -0.36652663 0.48065609 926.75 1.80780677e+00 -7.36550123e-01 1.95209411e+00 -0.38689292 0.40556311 927.00 1.63425031e+00 -6.10057722e-01 1.74440376e+00 -0.35727517 0.28103807 927.25 1.89726827e+00 -7.64872007e-01 2.04564319e+00 -0.38321364 0.35331808 927.50 1.98122705e+00 -6.50710242e-01 2.08534996e+00 -0.31733830 0.40014841 927.75 1.82191621e+00 -6.68159342e-01 1.94057094e+00 -0.35150450 0.39176312 928.00 2.01929979e+00 -6.44533927e-01 2.11966876e+00 -0.30896515 0.37797690 928.25 1.88866099e+00 -6.35809869e-01 1.99281071e+00 -0.32472884 0.27505298 928.50 1.49043967e+00 -5.60911890e-01 1.59249256e+00 -0.35994484 0.18964608 928.75 1.54181943e+00 -5.06850656e-01 1.62299253e+00 -0.31760674 0.16367289 929.00 2.16358075e+00 -5.53607232e-01 2.23328516e+00 -0.25050082 0.22338508 929.25 1.85296800e+00 -1.95023685e-01 1.86320279e+00 -0.10486329 0.14741758 929.50 2.42028759e+00 -5.95951396e-01 2.49257901e+00 -0.24142884 0.25040135 929.75 2.95538473e+00 -5.35891289e-01 3.00357760e+00 -0.17937807 0.34860113 930.00 3.44604711e+00 -1.07846921e+00 3.61086368e+00 -0.30330238 0.47653084 930.25 3.28567491e+00 -1.34036467e+00 3.54855422e+00 -0.38733409 0.41803529 930.50 3.23763984e+00 -1.58243288e+00 3.60366557e+00 -0.45461625 0.39930008 930.75 3.48758964e+00 -9.17839426e-01 3.60634312e+00 -0.25733784 0.36952403 931.00 2.74006628e+00 -8.73410241e-01 2.87590136e+00 -0.30857332 0.29011137 931.25 2.56557583e+00 -1.08908693e+00 2.78716517e+00 -0.40144706 0.33937677 931.50 2.19395947e+00 -8.49543837e-01 2.35269694e+00 -0.36944036 0.22645540 931.75 2.58018757e+00 -9.31326773e-01 2.74312549e+00 -0.34639910 0.27559725 932.00 3.19907396e+00 -1.01454468e+00 3.35609522e+00 -0.30710372 0.49933589 932.25 2.87494204e+00 -8.96202801e-01 3.01139024e+00 -0.30218231 0.41284141 932.50 2.39666978e+00 -1.43461145e+00 2.79323040e+00 -0.53937868 0.39213666 932.75 2.41095286e+00 -1.30733710e+00 2.74259439e+00 -0.49687298 0.38942949 933.00 2.43239706e+00 -1.04089962e+00 2.64575650e+00 -0.40435113 0.37999595 933.25 2.38327060e+00 -1.23280509e+00 2.68324191e+00 -0.47737150 0.48340561 933.50 2.40521150e+00 -1.25688872e+00 2.71381864e+00 -0.48153928 0.45208591 933.75 2.63838736e+00 -1.09932892e+00 2.85825331e+00 -0.39479140 0.46310992 934.00 2.26345525e+00 -5.87062801e-01 2.33834822e+00 -0.25377389 0.32997986 934.25 2.16690908e+00 -5.20684743e-01 2.22858869e+00 -0.23581837 0.33806952 934.50 2.34770056e+00 -8.45278078e-01 2.49523405e+00 -0.34559550 0.38125897 934.75 2.43300945e+00 -9.71653340e-01 2.61985595e+00 -0.37995690 0.45072797 935.00 2.01546319e+00 -1.51565795e+00 2.52176742e+00 -0.64478927 0.35732001 935.25 2.14729317e+00 -1.94553470e+00 2.89758058e+00 -0.73614242 0.35511699 935.50 3.12295673e+00 -1.43602544e+00 3.43729949e+00 -0.43099743 0.48461296 935.75 3.61627499e+00 -1.29830326e+00 3.84226966e+00 -0.34468486 0.50672287 936.00 4.14266858e+00 -9.80722210e-01 4.25717265e+00 -0.23245725 0.65531734 936.25 4.10235927e+00 -1.19543828e+00 4.27298774e+00 -0.28355076 0.70157629 936.50 4.09724515e+00 -1.41292200e+00 4.33402427e+00 -0.33207667 0.71533499 936.75 4.48836392e+00 -2.02821059e+00 4.92534759e+00 -0.42441784 0.74130080 937.00 4.66606864e+00 -2.43474747e+00 5.26309717e+00 -0.48093392 0.72994334 937.25 4.37817215e+00 -2.06232170e+00 4.83958285e+00 -0.44021752 0.70174105 937.50 3.65780263e+00 -1.82313304e+00 4.08697127e+00 -0.46238523 0.61279532 937.75 4.40955960e+00 -2.09872647e+00 4.88353035e+00 -0.44422253 0.64000653 938.00 5.38519062e+00 -1.88937619e+00 5.70701502e+00 -0.33742889 0.69423276 938.25 5.21639133e+00 -1.81091123e+00 5.52178757e+00 -0.33414060 0.67743837 938.50 5.41470492e+00 -2.11497905e+00 5.81310293e+00 -0.37237600 0.77626546 938.75 5.92255416e+00 -1.99338728e+00 6.24901917e+00 -0.32466576 0.82093030 939.00 5.81360164e+00 -1.65349020e+00 6.04417023e+00 -0.27710036 0.80775120 939.25 5.98085685e+00 -2.16709478e+00 6.36136373e+00 -0.34762425 0.74884988 939.50 5.87208598e+00 -1.71058930e+00 6.11616788e+00 -0.28346411 0.71657140 939.75 5.70103232e+00 -1.63961723e+00 5.93212561e+00 -0.28004224 0.75337729 940.00 6.30506250e+00 -1.78442735e+00 6.55270891e+00 -0.27580233 0.79684349 940.25 6.37299277e+00 -2.37073533e+00 6.79966344e+00 -0.35613546 0.77994662 940.50 6.25246753e+00 -2.35330687e+00 6.68067387e+00 -0.35998042 0.77460298 940.75 6.37101591e+00 -2.25057712e+00 6.75684402e+00 -0.33956940 0.82487727 941.00 6.76903216e+00 -3.12575993e+00 7.45588167e+00 -0.43260155 0.87267475 941.25 7.20024277e+00 -3.74326736e+00 8.11514303e+00 -0.47942539 0.91196998 941.50 7.10453664e+00 -3.70423798e+00 8.01222939e+00 -0.48061321 0.90191976 941.75 7.43285313e+00 -4.21596640e+00 8.54527228e+00 -0.51595792 0.90233856 942.00 7.43432047e+00 -4.40211581e+00 8.63989262e+00 -0.53461579 0.90833901 942.25 6.59575804e+00 -5.09069388e+00 8.33181783e+00 -0.65731609 0.89878518 942.50 6.55636318e+00 -5.39535466e+00 8.49092163e+00 -0.68856044 0.90742020 942.75 6.77031317e+00 -5.79106426e+00 8.90918434e+00 -0.70759839 0.93958885 943.00 6.76398732e+00 -5.91521795e+00 8.98561783e+00 -0.71855605 0.94765424 943.25 6.55076557e+00 -6.62555071e+00 9.31721266e+00 -0.79107383 0.93537543 943.50 6.63299363e+00 -6.65639879e+00 9.39703407e+00 -0.78715935 0.94093278 943.75 6.50107256e+00 -6.47915354e+00 9.17841899e+00 -0.78370952 0.95359881 944.00 6.51303056e+00 -6.54144790e+00 9.23093212e+00 -0.78757499 0.94490114 944.25 6.66623459e+00 -7.59380183e+00 1.01046776e+01 -0.85035328 0.94333439 944.50 6.65650305e+00 -7.84577921e+00 1.02890857e+01 -0.86722121 0.94068566 944.75 6.34101702e+00 -8.15546503e+00 1.03305424e+01 -0.90991533 0.91326703 945.00 5.73129495e+00 -8.15956673e+00 9.97127228e+00 -0.95846019 0.88832998 945.25 5.49508051e+00 -8.79083606e+00 1.03670009e+01 -1.01213092 0.94946365 945.50 5.00274959e+00 -8.69352347e+00 1.00301971e+01 -1.04861861 0.95417657 945.75 4.99015453e+00 -8.29805718e+00 9.68294352e+00 -1.02937434 0.95513347 946.00 4.93826975e+00 -8.36581574e+00 9.71459629e+00 -1.03754603 0.95945329 946.25 4.98003312e+00 -8.57386908e+00 9.91523883e+00 -1.04458534 0.97609115 946.50 4.71951303e+00 -9.07625498e+00 1.02299662e+01 -1.09128914 0.97520229 946.75 4.06380731e+00 -9.56345946e+00 1.03910676e+01 -1.16898440 0.96705283 947.00 3.62494482e+00 -9.81074622e+00 1.04590136e+01 -1.21686756 0.97270687 947.25 3.39095908e+00 -9.96682956e+00 1.05278818e+01 -1.24285664 0.97025123 947.50 2.93083972e+00 -1.02219566e+01 1.06338243e+01 -1.29156708 0.96600632 947.75 2.53070922e+00 -1.03528760e+01 1.06576982e+01 -1.33105265 0.97614149 948.00 2.25318251e+00 -1.02709963e+01 1.05152364e+01 -1.35484385 0.96068937 948.25 1.80852532e+00 -9.65930854e+00 9.82715653e+00 -1.38570792 0.94824076 948.50 8.51965037e-01 -9.41682627e+00 9.45528748e+00 -1.48056934 0.94472024 948.75 2.12223187e-01 -9.12614834e+00 9.12861557e+00 -1.54754611 0.94459293 949.00 -4.89965355e-02 -8.66149404e+00 8.66163263e+00 -1.57645309 0.94256624 949.25 -3.29710653e-01 -8.19560410e+00 8.20223358e+00 -1.61100483 0.95417722 949.50 -1.42493999e-01 -7.61099410e+00 7.61232787e+00 -1.58951627 0.95658835 949.75 -1.82189106e-01 -7.26482672e+00 7.26711085e+00 -1.59586932 0.93820347 950.00 -3.56703635e-02 -6.58696442e+00 6.58706101e+00 -1.57621157 0.87798425 950.25 1.06311759e-01 -6.13867093e+00 6.13959144e+00 -1.55347969 0.86704728 950.50 7.46574145e-01 -6.18769728e+00 6.23257335e+00 -1.45072214 0.90463476 950.75 1.03776508e+00 -5.75578487e+00 5.84859092e+00 -1.39241331 0.89951906 951.00 1.37853553e+00 -5.61431325e+00 5.78107892e+00 -1.33002019 0.86400376 951.25 1.81927122e+00 -5.54291635e+00 5.83383831e+00 -1.25365885 0.85385694 951.50 2.56981509e+00 -5.82493919e+00 6.36662126e+00 -1.15530581 0.87183170 951.75 2.69960675e+00 -5.70747651e+00 6.31372828e+00 -1.12898532 0.87287131 952.00 3.35703702e+00 -5.32057314e+00 6.29112042e+00 -1.00792692 0.86946587 952.25 3.47577443e+00 -5.48852832e+00 6.49653377e+00 -1.00626510 0.88729980 952.50 3.50022823e+00 -6.06569958e+00 7.00316422e+00 -1.04742077 0.87279088 952.75 4.16899333e+00 -6.21360702e+00 7.48260767e+00 -0.97983712 0.86327376 953.00 5.11943440e+00 -5.65388855e+00 7.62725799e+00 -0.83496656 0.84296774 953.25 5.35650042e+00 -5.36605829e+00 7.58199699e+00 -0.78628954 0.83356907 953.50 6.72098513e+00 -5.41153515e+00 8.62880952e+00 -0.67788540 0.88741421 953.75 7.35780147e+00 -5.55614679e+00 9.21997883e+00 -0.64678057 0.89701818 954.00 9.82566463e+00 -6.27263348e+00 1.16571702e+01 -0.56817217 0.83089906 954.25 1.12758675e+01 -6.57837259e+00 1.30545078e+01 -0.52812627 0.85683435 954.50 1.30179423e+01 -6.20853661e+00 1.44226471e+01 -0.44501494 0.72685154 954.75 1.44740152e+01 -6.28192081e+00 1.57784551e+01 -0.40948049 0.64601254 955.00 1.53575481e+01 -4.02256889e+00 1.58756210e+01 -0.25617295 0.48431066 955.25 1.48699570e+01 -7.13932260e+00 1.64950159e+01 -0.44761525 0.41997376 955.50 1.59695289e+01 -5.97287824e+00 1.70499598e+01 -0.35790875 0.25303602 955.75 1.52302798e+01 -2.42637388e+00 1.54223446e+01 -0.15798485 0.22857005 956.00 9.01232469e+00 -2.33837106e+00 9.31074516e+00 -0.25386565 0.11737093 956.25 5.79971338e+00 4.90931203e-01 5.82045434e+00 0.08444619 0.04909940 956.50 1.79087779e+00 2.30416737e+00 2.91829240e+00 0.91009191 0.01136723 956.75 -2.57075342e+00 3.85677154e+00 4.63502533e+00 2.15872217 0.03864419 957.00 -1.90854493e+00 4.38886075e+00 4.78587949e+00 1.98098970 0.05576592 957.25 -4.63705142e-01 3.49475620e+00 3.52538556e+00 1.70271176 0.03695472 957.50 -1.66687312e+00 6.22218624e+00 6.44158890e+00 1.83254223 0.15671186 957.75 -1.44013540e+00 4.13039596e+00 4.37426116e+00 1.90628369 0.08277864 958.00 4.62685940e-01 3.38543590e+00 3.41690715e+00 1.43496831 0.07393629 958.25 5.90460458e-01 2.76757582e+00 2.82986209e+00 1.36059844 0.04963171 958.50 7.86836188e-01 2.51751563e+00 2.63761183e+00 1.26787073 0.03315895 958.75 1.24677170e+00 1.83639920e+00 2.21964000e+00 0.97435723 0.03147069 959.00 6.20134955e+00 4.09539435e-01 6.21485790e+00 0.06594462 0.18940277 959.25 1.03252969e+01 -1.33103787e+00 1.04107357e+01 -0.12820334 0.44774806 959.50 8.64795906e+00 -2.37623443e+00 8.96848293e+00 -0.26815610 0.48544401 959.75 5.52693042e+00 -3.56368714e+00 6.57623189e+00 -0.57270108 0.27327607 960.00 5.18373537e+00 -4.79272196e+00 7.05983684e+00 -0.74622460 0.39518059 960.25 4.50490512e+00 -5.10202068e+00 6.80623135e+00 -0.84747301 0.35877001 960.50 4.94240077e+00 -7.17611008e+00 8.71343109e+00 -0.96767438 0.46857972 960.75 4.57639713e+00 -1.01240033e+01 1.11103040e+01 -1.14625193 0.72043716 961.00 3.80359973e+00 -1.02566985e+01 1.09392521e+01 -1.21567727 0.76080851 961.25 2.70842660e+00 -1.08822821e+01 1.12142605e+01 -1.32686823 0.82453735 961.50 1.41104484e+00 -1.08793634e+01 1.09704874e+01 -1.44181712 0.82461263 961.75 6.35570027e-01 -1.14547818e+01 1.14724006e+01 -1.51536803 0.80237766 962.00 -4.00081966e-01 -1.15423871e+01 1.15493188e+01 -1.60544443 0.83078924 962.25 -2.59972530e+00 -1.06251636e+01 1.09385865e+01 -1.81075817 0.85328485 962.50 -3.59393885e+00 -1.05000561e+01 1.10980888e+01 -1.90057542 0.88860191 962.75 -4.92398430e+00 -1.04123876e+01 1.15179615e+01 -2.01252721 0.90980338 963.00 -5.53706367e+00 -1.00841306e+01 1.15042933e+01 -2.07293820 0.91202210 963.25 -6.37096675e+00 -9.37279135e+00 1.13330682e+01 -2.16778828 0.89970564 963.50 -6.12018259e+00 -8.87195145e+00 1.07781333e+01 -2.17466751 0.90654710 963.75 -6.44321292e+00 -7.64276531e+00 9.99634204e+00 -2.27124014 0.84666220 964.00 -7.26585912e+00 -6.85882588e+00 9.99180670e+00 -2.38500367 0.87950657 964.25 -7.60950506e+00 -5.81823620e+00 9.57895817e+00 -2.48881212 0.87757620 964.50 -7.66423274e+00 -5.37599207e+00 9.36171748e+00 -2.52990154 0.84361863 964.75 -7.70569968e+00 -4.25952515e+00 8.80462163e+00 -2.63662072 0.83575947 965.00 -7.27452103e+00 -4.23959443e+00 8.41978724e+00 -2.61391586 0.81678772 965.25 -6.87189182e+00 -3.34610856e+00 7.64325452e+00 -2.68845816 0.81052129 965.50 -6.47769905e+00 -3.28828366e+00 7.26452989e+00 -2.67185855 0.83843157 965.75 -5.28275998e+00 -3.40724110e+00 6.28624251e+00 -2.56875900 0.81888093 966.00 -5.14666098e+00 -2.97931167e+00 5.94679891e+00 -2.61684551 0.78114642 966.25 -4.60197616e+00 -2.96425146e+00 5.47402697e+00 -2.56935803 0.74640329 966.50 -4.24656449e+00 -2.86828137e+00 5.12448514e+00 -2.54754371 0.74524961 966.75 -4.67574466e+00 -2.76775854e+00 5.43351410e+00 -2.60712098 0.81613755 967.00 -4.64769726e+00 -2.24772760e+00 5.16269011e+00 -2.69113326 0.80951134 967.25 -4.42508307e+00 -1.82537389e+00 4.78678911e+00 -2.75035184 0.77819394 967.50 -3.68949903e+00 -1.85980437e+00 4.13173999e+00 -2.67468601 0.73049916 967.75 -3.54561555e+00 -1.97836089e+00 4.06020953e+00 -2.63264808 0.80765194 968.00 -3.18383123e+00 -2.09202988e+00 3.80964176e+00 -2.56025680 0.79194334 968.25 -2.88668240e+00 -2.04098629e+00 3.53533030e+00 -2.52616062 0.81098425 968.50 -2.81453631e+00 -2.30621887e+00 3.63871682e+00 -2.45513646 0.78889620 968.75 -3.05387964e+00 -2.50239601e+00 3.94818523e+00 -2.45512466 0.82676798 969.00 -2.77491497e+00 -2.78229219e+00 3.92954234e+00 -2.35486699 0.80080714 969.25 -2.86496733e+00 -2.83008477e+00 4.02708550e+00 -2.36231948 0.84575408 969.50 -2.78348172e+00 -2.70445784e+00 3.88096156e+00 -2.37059305 0.78641211 969.75 -2.89873476e+00 -2.34858275e+00 3.73075115e+00 -2.46065727 0.74546408 970.00 -2.75764847e+00 -2.69695475e+00 3.85722569e+00 -2.36732110 0.71933357 970.25 -3.34943380e+00 -3.10722607e+00 4.56875920e+00 -2.39368976 0.84454214 970.50 -3.15415262e+00 -2.76939269e+00 4.19740570e+00 -2.42105770 0.78319377 970.75 -2.43064938e+00 -2.98226685e+00 3.84733310e+00 -2.25463745 0.76566370 971.00 -2.86270145e+00 -3.39370929e+00 4.43985612e+00 -2.27152322 0.80472461 971.25 -3.22968014e+00 -3.30166291e+00 4.61863744e+00 -2.34517381 0.81912880 971.50 -3.28792693e+00 -3.09546791e+00 4.51579286e+00 -2.38633531 0.80162741 971.75 -3.02536631e+00 -3.07537394e+00 4.31401973e+00 -2.34799770 0.77111093 972.00 -3.05942078e+00 -3.08380017e+00 4.34394740e+00 -2.35222601 0.70580878 972.25 -3.29113646e+00 -3.09471994e+00 4.51761781e+00 -2.38694285 0.70634282 972.50 -3.19876557e+00 -3.48228302e+00 4.72846658e+00 -2.31378387 0.65357097 972.75 -3.33626102e+00 -3.55003817e+00 4.87169463e+00 -2.32516062 0.69919551 973.00 -3.70138386e+00 -4.04850895e+00 5.48549607e+00 -2.31143345 0.79567861 973.25 -3.30521790e+00 -4.50096098e+00 5.58418437e+00 -2.20419691 0.83117089 973.50 -3.38545013e+00 -5.08987122e+00 6.11294214e+00 -2.15773761 0.81862595 973.75 -3.09027209e+00 -5.42243261e+00 6.24119836e+00 -2.08879324 0.79531195 974.00 -3.04114453e+00 -5.89029616e+00 6.62903831e+00 -2.04739668 0.78825414 974.25 -3.85171776e+00 -6.57920413e+00 7.62375608e+00 -2.10043984 0.77458983 974.50 -4.65740731e+00 -6.39503871e+00 7.91125546e+00 -2.20025402 0.73620348 974.75 -4.55406315e+00 -7.01684863e+00 8.36514530e+00 -2.14648111 0.72336394 975.00 -5.70896664e+00 -7.81298857e+00 9.67652264e+00 -2.20183191 0.73733506 975.25 -6.54984476e+00 -7.31127850e+00 9.81607150e+00 -2.30131660 0.72801818 975.50 -7.38287283e+00 -7.13547374e+00 1.02675117e+01 -2.37323329 0.75093847 975.75 -7.50505452e+00 -6.70160026e+00 1.00616743e+01 -2.41268909 0.69035780 976.00 -8.18788893e+00 -5.47062952e+00 9.84729976e+00 -2.55257299 0.61897557 976.25 -1.00968781e+01 -5.23938224e+00 1.13753274e+01 -2.66293087 0.62954915 976.50 -1.11207083e+01 -6.24029814e+00 1.27519204e+01 -2.63023528 0.67911668 976.75 -1.14510946e+01 -6.84155349e+00 1.33392062e+01 -2.60304402 0.68542157 977.00 -1.19371538e+01 -6.16928507e+00 1.34371023e+01 -2.66458471 0.71729009 977.25 -1.23214440e+01 -5.06440990e+00 1.33216452e+01 -2.75161905 0.69211393 977.50 -1.35729506e+01 -5.70057706e+00 1.47214662e+01 -2.74396856 0.67954529 977.75 -1.22673853e+01 -6.55063823e+00 1.39068186e+01 -2.65112567 0.57778940 978.00 -1.13747251e+01 -5.17870261e+00 1.24981331e+01 -2.71435527 0.40663695 978.25 -1.30961448e+01 -5.92613958e+00 1.43745657e+01 -2.71665318 0.44599074 978.50 -1.35964983e+01 -6.18489002e+00 1.49371226e+01 -2.71468094 0.50299239 978.75 -1.14557202e+01 -3.75541527e+00 1.20555659e+01 -2.82481219 0.39325692 979.00 -1.08165169e+01 -2.53744887e+00 1.11101613e+01 -2.91116908 0.28786696 979.25 -7.84014737e+00 -4.13940209e+00 8.86580850e+00 -2.65581629 0.19586388 979.50 -4.48598415e+00 -4.38202882e+00 6.27106294e+00 -2.36791646 0.11750401 979.75 -3.04920894e+00 -1.79494334e+00 3.53829009e+00 -2.60955409 0.04421702 980.00 -3.48666821e+00 -1.50818336e+00 3.79887777e+00 -2.73333846 0.05558509 980.25 -3.78691858e+00 -2.54400437e+00 4.56209498e+00 -2.55005327 0.09074095 980.50 -2.08815826e+00 -2.83168891e+00 3.51836140e+00 -2.20620075 0.05758561 980.75 1.42001116e+00 -3.29507888e+00 3.58803240e+00 -1.16389758 0.06480134 981.00 3.88746631e+00 -1.33071314e+00 4.10891613e+00 -0.32980643 0.07949836 981.25 2.34562364e+00 1.79165941e-01 2.35245631e+00 0.07623504 0.04687581 981.50 2.77797090e+00 -3.42905686e-01 2.79905460e+00 -0.12281620 0.08790077 981.75 3.31521433e+00 -1.29974367e+00 3.56089590e+00 -0.37363783 0.12003090 982.00 2.16326543e+00 -8.87901725e-01 2.33839406e+00 -0.38947823 0.06555008 982.25 2.18469512e+00 -1.25162447e+00 2.51782775e+00 -0.52025900 0.09994801 982.50 2.42803356e+00 -1.04027699e+00 2.64150018e+00 -0.40478433 0.14709829 982.75 1.87678361e+00 -6.13099123e-01 1.97438781e+00 -0.31574654 0.10605752 983.00 1.52020438e+00 -3.81307876e-01 1.56729609e+00 -0.24575660 0.06862901 983.25 1.33971179e+00 8.08225184e-01 1.56462635e+00 0.54282988 0.06307912 983.50 8.30386468e-01 5.16009957e-01 9.77654316e-01 0.55601314 0.02539156 983.75 9.54641522e-01 1.04478852e+00 1.41524680e+00 0.83045400 0.03176000 984.00 1.63931318e+00 1.54805283e+00 2.25473176e+00 0.75677408 0.08023224 984.25 2.05129719e+00 7.12446798e-01 2.17149732e+00 0.33428106 0.09490075 984.50 2.15633449e+00 -3.88970925e-01 2.19113596e+00 -0.17846607 0.12037019 984.75 2.64844063e+00 -1.44685530e+00 3.01788469e+00 -0.50000162 0.16358610 985.00 2.49886441e+00 -8.06763344e-01 2.62586946e+00 -0.31228787 0.10763453 985.25 3.65340372e+00 -1.36605279e+00 3.90044343e+00 -0.35781678 0.19864528 985.50 2.86575975e+00 -1.53728353e+00 3.25204853e+00 -0.49236622 0.18673493 985.75 1.48254513e+00 -4.78399424e-01 1.55782094e+00 -0.31213929 0.04379602 986.00 2.40591048e+00 -1.07436515e+00 2.63489387e+00 -0.41998322 0.07665124 986.25 4.24199579e+00 -8.24160690e-01 4.32131568e+00 -0.19189541 0.19150795 986.50 2.96265288e+00 -1.76672495e+00 3.44943896e+00 -0.53771813 0.12316066 986.75 1.06010672e+00 -6.45163512e+00 6.53815126e+00 -1.40793568 0.42108953 987.00 1.83696791e+00 -6.92409877e+00 7.16363001e+00 -1.31146969 0.42889852 987.25 1.96184217e+00 -5.93819779e+00 6.25388021e+00 -1.25170910 0.51409637 987.50 1.43802045e+00 -5.58774833e+00 5.76982098e+00 -1.31890982 0.60658704 987.75 1.59146102e+00 -5.03039167e+00 5.27613386e+00 -1.26439038 0.63023434 988.00 6.84187827e-01 -4.90161698e+00 4.94913750e+00 -1.43210831 0.57533440 988.25 4.62212926e-01 -4.62521423e+00 4.64825208e+00 -1.47119371 0.57437087 988.50 5.88601498e-01 -3.96556996e+00 4.00901445e+00 -1.42344417 0.48160291 988.75 9.01895904e-01 -3.68679360e+00 3.79550567e+00 -1.33087926 0.45730013 989.00 7.61501839e-01 -3.33265779e+00 3.41855130e+00 -1.34615603 0.35103880 989.25 3.58875548e-01 -3.75713803e+00 3.77423871e+00 -1.47556691 0.38766658 989.50 3.77618214e-01 -3.53106376e+00 3.55119794e+00 -1.46425946 0.45237050 989.75 2.75970040e-02 -2.95071270e+00 2.95084175e+00 -1.56144394 0.37042939 990.00 -7.12406558e-02 -2.85604465e+00 2.85693302e+00 -1.59573497 0.31113243 990.25 -3.73454237e-01 -2.43898816e+00 2.46741389e+00 -1.72273476 0.30350202 990.50 -2.22140194e-01 -1.81600460e+00 1.82954064e+00 -1.69251522 0.27113376 990.75 8.65810935e-02 -1.79159575e+00 1.79368660e+00 -1.52250765 0.29986148 991.00 6.95998809e-02 -1.22080694e+00 1.22278932e+00 -1.51384660 0.15293999 991.25 5.01895427e-01 -7.08338516e-01 8.68125839e-01 -0.95435309 0.10045148 991.50 6.39909570e-01 -4.68935779e-01 7.93337899e-01 -0.63241214 0.07495345 991.75 9.46853420e-01 -6.27125772e-01 1.13570160e+00 -0.58499160 0.16066142 992.00 1.27431688e+00 -6.88886589e-01 1.44860217e+00 -0.49559215 0.32368677 992.25 1.24566792e+00 -6.03967306e-01 1.38436450e+00 -0.45145771 0.32783808 992.50 8.02452935e-01 -4.65527323e-01 9.27710300e-01 -0.52568135 0.17680108 992.75 7.11107397e-01 -4.12167334e-01 8.21921919e-01 -0.52529442 0.16854682 993.00 1.50607516e+00 -2.82963357e-01 1.53242639e+00 -0.18571627 0.49223585 993.25 1.83986639e+00 -1.00387169e-01 1.84260303e+00 -0.05450816 0.63389536 993.50 1.87441632e+00 3.34546135e-01 1.90403720e+00 0.17662041 0.53712013 993.75 1.99946477e+00 6.87204722e-01 2.11426339e+00 0.33104630 0.66955008 994.00 2.14641547e+00 7.48675636e-01 2.27323879e+00 0.33560784 0.64441126 994.25 2.32686291e+00 9.69381937e-01 2.52071267e+00 0.39473829 0.67449550 994.50 2.22996065e+00 8.83833306e-01 2.39872588e+00 0.37735138 0.60855584 994.75 2.28777887e+00 1.15916534e+00 2.56468252e+00 0.46897507 0.60549679 995.00 2.57149085e+00 1.34263736e+00 2.90090336e+00 0.48118984 0.60740715 995.25 2.59062803e+00 1.71839987e+00 3.10873796e+00 0.58567794 0.57008776 995.50 1.50601324e+00 1.98375381e+00 2.49065354e+00 0.92145001 0.32940920 995.75 1.30715896e+00 2.59879457e+00 2.90902007e+00 1.10476226 0.35584921 996.00 1.53482073e+00 4.58162608e+00 4.83187047e+00 1.24755123 0.52209212 996.25 1.52727969e+00 5.34920782e+00 5.56296751e+00 1.29268081 0.49030814 996.50 2.11743916e+00 4.91503755e+00 5.35174203e+00 1.16401627 0.26765871 996.75 2.96300046e+00 4.35958462e+00 5.27118106e+00 0.97385766 0.26074161 997.00 4.98514346e+00 3.81919107e+00 6.27995826e+00 0.65373492 0.30934532 997.25 3.86173631e+00 9.64800231e-01 3.98043299e+00 0.24482418 0.12696199 997.50 3.29374058e+00 -1.82482387e+00 3.76546268e+00 -0.50593032 0.14737713 997.75 2.26821131e+00 -5.25518443e-01 2.32829384e+00 -0.22767145 0.07976933 998.00 2.25782975e+00 -6.99900805e-01 2.36382239e+00 -0.30059500 0.09265313 998.25 2.07884427e+00 5.40507191e-01 2.14796217e+00 0.25437152 0.11388212 998.50 2.11784003e+00 1.40581217e+00 2.54195874e+00 0.58601207 0.18728182 998.75 1.84196655e+00 2.21397356e+00 2.88002078e+00 0.87686132 0.18867033 999.00 1.06980844e+00 3.09132533e+00 3.27120503e+00 1.23762878 0.15344894 999.25 3.13335158e+00 2.13164696e+00 3.78969799e+00 0.59738785 0.22105045 999.50 4.98262120e+00 2.13626333e+00 5.42126692e+00 0.40503662 0.48713846 999.75 5.86460303e+00 8.18133084e-01 5.92139430e+00 0.13860903 0.48390638 1000.00 6.79962915e+00 0.00000000e+00 6.79962915e+00 0.00000000 0.52243788