========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R2 (vertical) Quiet acquisition : SIG0059 Injection acquisition : SIG0060 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -8.23499180e-02 0.00000000e+00 8.23499180e-02 3.14159265 0.32310531 0.25 -8.44853744e-02 -8.67261750e-04 8.44898256e-02 -3.13132778 0.33067858 0.50 -1.58765883e-01 2.09647829e-02 1.60144084e-01 3.01030381 0.66084069 0.75 -1.55629098e-01 6.59923788e-03 1.55768950e-01 3.09921442 0.68288051 1.00 -1.56844752e-01 3.41678324e-03 1.56881964e-01 3.11981161 0.64939579 1.25 -1.64505159e-01 3.39662203e-03 1.64540222e-01 3.12094808 0.66617073 1.50 -1.53868804e-01 6.26158502e-03 1.53996157e-01 3.10092078 0.57812339 1.75 -1.57566801e-01 1.83720721e-03 1.57577512e-01 3.12993332 0.63093496 2.00 -1.61564287e-01 -3.44745273e-04 1.61564655e-01 -3.13945886 0.64808600 2.25 -1.61119680e-01 -2.05536837e-03 1.61132789e-01 -3.12883657 0.60229347 2.50 -1.64922623e-01 -1.51998421e-03 1.64929628e-01 -3.13237657 0.59007083 2.75 -1.62978266e-01 -2.66658786e-03 1.63000080e-01 -3.12523250 0.58194494 3.00 -1.57928753e-01 -6.31057694e-03 1.58054783e-01 -3.10165552 0.55291080 3.25 -1.64501152e-01 7.16237301e-05 1.64501167e-01 3.14115725 0.54956815 3.50 -1.69018440e-01 -6.48312594e-03 1.69142733e-01 -3.10325394 0.53262797 3.75 -1.61514230e-01 1.35255236e-04 1.61514287e-01 3.14075523 0.54020906 4.00 -1.62015319e-01 -2.86716842e-03 1.62040687e-01 -3.12389760 0.52775242 4.25 -1.65177288e-01 3.62735625e-05 1.65177292e-01 3.14137305 0.49235168 4.50 -1.66310350e-01 -7.23395520e-04 1.66311923e-01 -3.13724301 0.49143645 4.75 -1.60814427e-01 7.76279978e-03 1.61001680e-01 3.09335831 0.47002395 5.00 -1.60333742e-01 7.40060553e-03 1.60504448e-01 3.09546789 0.45091237 5.25 -1.59489884e-01 -8.37924882e-04 1.59492085e-01 -3.13633892 0.39581737 5.50 -1.59522424e-01 5.21439278e-03 1.59607624e-01 3.10891677 0.39190476 5.75 -1.64299299e-01 3.26291910e-03 1.64331696e-01 3.12173566 0.41321201 6.00 -1.60427398e-01 -5.14490718e-04 1.60428223e-01 -3.13838566 0.38815600 6.25 -1.56042202e-01 7.41695890e-03 1.56218373e-01 3.09409665 0.39294509 6.50 -1.62259159e-01 3.11587989e-03 1.62289074e-01 3.12239191 0.38047749 6.75 -1.55883066e-01 1.48601401e-03 1.55890149e-01 3.13206007 0.32803221 7.00 -1.55604530e-01 7.19950792e-03 1.55770994e-01 3.09535764 0.32446745 7.25 -1.61626961e-01 3.88088419e-04 1.61627427e-01 3.13919152 0.30177809 7.50 -1.56640479e-01 1.75672590e-03 1.56650330e-01 3.13037811 0.28817922 7.75 -1.47611664e-01 1.32048693e-02 1.48201119e-01 3.05237333 0.24843068 8.00 -1.58000522e-01 6.73570692e-03 1.58144032e-01 3.09898754 0.26640868 8.25 -1.40635286e-01 4.76261662e-03 1.40715906e-01 3.10774057 0.21681585 8.50 -1.49211308e-01 6.45974328e-03 1.49351072e-01 3.09832708 0.23060566 8.75 -1.55376498e-01 5.22086745e-03 1.55464187e-01 3.10800389 0.22785013 9.00 -1.53379214e-01 2.98220352e-03 1.53408204e-01 3.12215177 0.22225564 9.25 -1.56321466e-01 1.38295265e-02 1.56932012e-01 3.05335387 0.22757948 9.50 -1.61685331e-01 3.35185158e-03 1.61720070e-01 3.12086491 0.21673376 9.75 -1.51959875e-01 -5.19340809e-03 1.52048595e-01 -3.10742977 0.18243316 10.00 -1.61738747e-01 2.78385282e-03 1.61762703e-01 3.12438232 0.21000646 10.25 -1.65174929e-01 9.90024757e-04 1.65177896e-01 3.13559893 0.22595144 10.50 -1.58478433e-01 3.27151480e-03 1.58512197e-01 3.12095230 0.19720548 10.75 -1.47524725e-01 3.16656476e-02 1.50884916e-01 2.93015452 0.18330693 11.00 -1.51989805e-01 5.92143972e-03 1.52105109e-01 3.10265289 0.16568905 11.25 -1.41775895e-01 -3.61603130e-03 1.41822001e-01 -3.11609292 0.13357087 11.50 -1.70854059e-01 -7.49957502e-03 1.71018575e-01 -3.09772619 0.19236400 11.75 -1.72721557e-01 -1.80292385e-02 1.73659983e-01 -3.03758605 0.18270094 12.00 -1.69605124e-01 -1.20322684e-03 1.69609392e-01 -3.13449849 0.18578873 12.25 -1.61937460e-01 2.09134925e-03 1.61950964e-01 3.12867882 0.17608069 12.50 -1.54718393e-01 -9.14108906e-03 1.54988195e-01 -3.08257915 0.13714844 12.75 -1.54056326e-01 -2.09796649e-02 1.55478288e-01 -3.00624348 0.12035450 13.00 -1.59289573e-01 1.55641835e-03 1.59297177e-01 3.13182197 0.14565885 13.25 -1.57426530e-01 -8.36913344e-03 1.57648834e-01 -3.08848050 0.13932859 13.50 -1.56506513e-01 4.56655817e-03 1.56573120e-01 3.11242286 0.14169858 13.75 -1.45458773e-01 6.38136875e-03 1.45598683e-01 3.09775013 0.12169631 14.00 -1.32685390e-01 1.37317240e-02 1.33394051e-01 3.03846892 0.09120867 14.25 -1.25941358e-01 -5.33831064e-04 1.25942489e-01 -3.13735395 0.07651189 14.50 -1.58822683e-01 9.48363686e-03 1.59105575e-01 3.08195136 0.12884472 14.75 -1.68225714e-01 -4.07110847e-03 1.68274968e-01 -3.11739710 0.14497351 15.00 -9.31518767e-02 1.17046451e-02 9.38843483e-02 3.01659653 0.04707583 15.25 -8.06073171e-02 -7.81424998e-03 8.09851967e-02 -3.04495244 0.03529020 15.50 -1.30179183e-01 7.25720738e-03 1.30381313e-01 3.08590246 0.07407490 15.75 -1.29214698e-01 6.08746564e-03 1.29358013e-01 3.09451621 0.07079842 16.00 -1.70178866e-01 1.27392157e-02 1.70655015e-01 3.06687421 0.12933000 16.25 -1.55585447e-01 -4.87140534e-03 1.55661691e-01 -3.11029272 0.09597492 16.50 -1.40142188e-01 4.16958462e-02 1.46213462e-01 2.85240777 0.09601218 16.75 -1.52547140e-01 3.29104206e-02 1.56056802e-01 2.92910992 0.10448800 17.00 -1.35896809e-01 -1.54765765e-02 1.36775243e-01 -3.02819644 0.06532926 17.25 -1.46391037e-01 1.87909671e-03 1.46403096e-01 3.12875721 0.07924127 17.50 -1.75452256e-01 -1.63197837e-02 1.76209618e-01 -3.04884400 0.10490429 17.75 -1.65974051e-01 -3.93578627e-02 1.70576748e-01 -2.90876064 0.09319007 18.00 -1.46012889e-01 9.84291297e-03 1.46344275e-01 3.07428323 0.08520562 18.25 -1.52845831e-01 3.51283387e-03 1.52886193e-01 3.11861384 0.08841293 18.50 -1.32623733e-01 -1.38792804e-02 1.33348000e-01 -3.03732065 0.06416383 18.75 -1.21614030e-01 1.87377164e-04 1.21614174e-01 3.14005190 0.05308988 19.00 -8.45200934e-02 1.73694326e-02 8.62864032e-02 2.93890799 0.02559816 19.25 -1.27536759e-01 1.93541978e-03 1.27551444e-01 3.12641843 0.05201277 19.50 -1.05095840e-01 1.21261330e-02 1.05793094e-01 3.02671896 0.03964558 19.75 -1.24496576e-01 -1.78475713e-02 1.25769365e-01 -2.99920486 0.04801297 20.00 -1.44947497e-01 -5.72085812e-02 1.55828748e-01 -2.76567668 0.07049051 20.25 -1.48763080e-01 -1.19019230e-02 1.49238432e-01 -3.06175681 0.06393255 20.50 -1.50215234e-01 -2.65453367e-02 1.52542687e-01 -2.96668310 0.06700954 20.75 -1.57830420e-01 1.04792957e-02 1.58177929e-01 3.07529404 0.06958607 21.00 -1.45212405e-01 -1.02341500e-02 1.45572595e-01 -3.07123189 0.06566161 21.25 -1.55132651e-01 -9.57730509e-03 1.55428003e-01 -3.07993468 0.06384126 21.50 -1.52974587e-01 -2.27881337e-03 1.52991559e-01 -3.12669708 0.05997699 21.75 -1.53253285e-01 -1.07402539e-02 1.53629172e-01 -3.07162533 0.06137806 22.00 -1.39705856e-01 2.41623367e-02 1.41779917e-01 2.97033531 0.05108477 22.25 -1.09086009e-01 -1.33019021e-03 1.09094118e-01 -3.12939930 0.03186507 22.50 -8.36057603e-02 -7.18139069e-03 8.39136194e-02 -3.05590709 0.01940732 22.75 -1.17526436e-01 2.02735681e-02 1.19262235e-01 2.97077159 0.03628084 23.00 -9.71665690e-02 2.26499785e-02 9.97715573e-02 2.91257761 0.02608520 23.25 -1.38123478e-01 1.87848581e-02 1.39395000e-01 3.00642149 0.04578175 23.50 -1.47682611e-01 -2.51811170e-02 1.49814026e-01 -2.97270848 0.04411225 23.75 -4.75864197e-02 -4.30037825e-02 6.41388544e-02 -2.40673786 0.00997478 24.00 -4.36075906e-02 -7.97768335e-02 9.09173533e-02 -2.07104061 0.02106087 24.25 -1.11606318e-01 -3.33307628e-02 1.16477079e-01 -2.85137867 0.02614931 24.50 -5.57859910e-02 -3.90657326e-02 6.81043923e-02 -2.53067977 0.00917260 24.75 -2.92578636e-02 -7.40051333e-02 7.95787807e-02 -1.94728690 0.01508639 25.00 -4.08643214e-02 -7.02678769e-02 8.12863290e-02 -2.09753957 0.01492723 25.25 -8.89434852e-02 -7.35720950e-02 1.15428752e-01 -2.45049804 0.02517358 25.50 -1.02360680e-01 -7.42544078e-02 1.26457210e-01 -2.51400971 0.02950473 25.75 -2.96260804e-02 -2.26442920e-02 3.72889877e-02 -2.48897920 0.00239083 26.00 1.23627962e-03 -4.04394898e-02 4.04583826e-02 -1.54023475 0.00257048 26.25 -8.67254163e-02 -4.89895796e-02 9.96056060e-02 -2.62739597 0.01958254 26.50 -1.05724861e-01 -4.79497768e-02 1.16090169e-01 -2.71580407 0.02567126 26.75 -1.01837229e-01 -2.14927577e-02 1.04080545e-01 -2.93359492 0.02165129 27.00 -1.16499499e-01 -5.70226829e-03 1.16638969e-01 -3.09268497 0.02554763 27.25 -1.35386171e-01 -3.14621550e-02 1.38993821e-01 -2.91325719 0.03352142 27.50 -1.27422923e-01 -2.95372993e-02 1.30801580e-01 -2.91381042 0.02974987 27.75 -1.22909255e-01 1.51644269e-02 1.23841208e-01 3.01883399 0.02387302 28.00 -1.28010881e-01 -5.09210889e-02 1.37766988e-01 -2.76299532 0.02946137 28.25 -1.48411194e-01 -3.95403095e-02 1.53588146e-01 -2.88121680 0.03478656 28.50 -1.35567551e-01 -1.45382249e-02 1.36344860e-01 -3.03476123 0.02798972 28.75 -1.11293543e-01 -6.03979206e-02 1.26626069e-01 -2.64437885 0.02503144 29.00 -1.13219525e-01 -2.89136590e-02 1.16853158e-01 -2.89155975 0.02087937 29.25 -2.01138909e-01 -8.03441352e-02 2.16591876e-01 -2.76156394 0.06688672 29.50 -1.96420790e-01 -4.98495915e-02 2.02647745e-01 -2.89305032 0.05596363 29.75 -1.16575606e-01 -1.22374652e-01 1.69013098e-01 -2.33193041 0.04414497 30.00 -1.58437491e-01 -7.12400360e-02 1.73716957e-01 -2.71903708 0.04190546 30.25 -1.69235580e-01 -7.60613744e-02 1.85542487e-01 -2.71920386 0.03944524 30.50 -1.58913935e-01 -4.73282843e-02 1.65811957e-01 -2.85213396 0.03232206 30.75 -8.53861359e-02 -1.06077337e-01 1.36173395e-01 -2.24854361 0.02241070 31.00 -1.32471981e-01 -1.02227007e-01 1.67329575e-01 -2.48435524 0.03366841 31.25 -1.19257080e-01 -1.24973651e-01 1.72744507e-01 -2.33279233 0.03924708 31.50 -1.51484021e-01 -3.92799602e-02 1.56493847e-01 -2.88787943 0.03469715 31.75 -1.32897459e-01 -3.05767250e-02 1.36369611e-01 -2.91545059 0.02682447 32.00 -2.07404436e-01 -2.67354358e-02 2.09120500e-01 -3.01339476 0.05787965 32.25 -2.74838638e-01 -7.10244427e-02 2.83867484e-01 -2.88870293 0.11843123 32.50 -1.88353694e-01 -1.49784227e-01 2.40650013e-01 -2.46976794 0.08966449 32.75 -1.81380985e-01 -1.36347645e-01 2.26913512e-01 -2.49699190 0.08236031 33.00 -1.48441133e-01 -6.00665265e-02 1.60133562e-01 -2.75708513 0.03653051 33.25 -1.87513216e-01 -9.07947762e-02 2.08338420e-01 -2.69066096 0.05306242 33.50 -1.86706140e-01 -1.41432461e-01 2.34227077e-01 -2.49330009 0.06991328 33.75 -1.67754919e-01 -1.63327189e-01 2.34131338e-01 -2.36956720 0.07640365 34.00 -2.86769164e-01 -1.08449067e-01 3.06590531e-01 -2.78004091 0.10484660 34.25 -3.25385237e-01 -1.41304411e-01 3.54742850e-01 -2.73189815 0.14043135 34.50 -2.47620433e-01 -1.25049412e-01 2.77404460e-01 -2.67394953 0.09525334 34.75 -2.21075934e-01 -1.58954567e-01 2.72288675e-01 -2.51822561 0.08965852 35.00 -2.35518052e-01 -7.43503406e-02 2.46975152e-01 -2.83580560 0.10315279 35.25 -2.61685109e-01 -2.85774367e-02 2.63240890e-01 -3.03281826 0.10786280 35.50 -2.90030811e-01 -1.14249785e-01 3.11722448e-01 -2.76633609 0.10897126 35.75 -2.95474942e-01 -1.27044733e-01 3.21629921e-01 -2.73552171 0.11554284 36.00 -2.98062795e-01 -1.18980254e-01 3.20932595e-01 -2.76179468 0.12566750 36.25 -4.06193934e-01 -1.74717315e-01 4.42176042e-01 -2.73538256 0.24723356 36.50 -5.02189949e-01 -2.40785509e-01 5.56931240e-01 -2.69450272 0.52879986 36.75 -4.20048739e-01 -1.97777311e-01 4.64280958e-01 -2.70154093 0.34827375 37.00 -1.76200827e-01 -7.93724129e-02 1.93252972e-01 -2.71835159 0.06234077 37.25 -1.77443324e-01 -5.50870636e-02 1.85797518e-01 -2.84057760 0.05801519 37.50 -1.85845834e-01 -9.52695647e-02 2.08841959e-01 -2.66789467 0.05893017 37.75 -1.93128138e-01 -1.27414402e-01 2.31371795e-01 -2.55840062 0.07176344 38.00 -2.02019057e-01 -1.36185904e-02 2.02477568e-01 -3.07428209 0.08453363 38.25 -1.98138665e-01 -1.34703678e-02 1.98596026e-01 -3.07371255 0.06185485 38.50 -1.97139142e-01 -1.87277534e-02 1.98026690e-01 -3.04687925 0.05163456 38.75 -2.21217633e-01 -3.46899492e-02 2.23921044e-01 -2.98604572 0.06745211 39.00 -1.30197695e-01 -1.83357731e-02 1.31482472e-01 -3.00168252 0.02826994 39.25 -1.17177520e-01 -5.05127461e-02 1.27601366e-01 -2.73458448 0.02332338 39.50 -9.43905684e-02 -1.25239786e-02 9.52178001e-02 -3.00968062 0.01457141 39.75 -1.52742875e-01 1.76949197e-02 1.53764418e-01 3.02625901 0.02657152 40.00 -1.71136559e-01 -1.96958397e-02 1.72266213e-01 -3.02700834 0.03005543 40.25 -1.24437633e-01 -5.50895608e-02 1.36086679e-01 -2.72481911 0.01815010 40.50 -1.55260107e-01 -1.44064400e-01 2.11802390e-01 -2.39358031 0.04346066 40.75 -8.66727829e-02 -3.14558168e-02 9.22043367e-02 -2.79344909 0.00773012 41.00 1.62900692e-02 9.00795391e-03 1.86147680e-02 0.50512220 0.00037852 41.25 -5.26614324e-02 -7.64720263e-02 9.28504027e-02 -2.17385503 0.00740991 41.50 -1.32578842e-01 -9.56003336e-02 1.63452051e-01 -2.51685679 0.02117778 41.75 -1.13654129e-01 -8.43927682e-02 1.41560589e-01 -2.50288289 0.01552144 42.00 -1.24318517e-01 -9.27064984e-02 1.55079298e-01 -2.50083796 0.01835124 42.25 -8.80566954e-02 -1.01425988e-01 1.34317581e-01 -2.28575442 0.01264841 42.50 -1.40423696e-02 -7.49664114e-02 7.62702496e-02 -1.75596602 0.00433955 42.75 -1.79483111e-01 -1.24343745e-01 2.18347324e-01 -2.53572338 0.03597403 43.00 -2.66689452e-01 -1.64351749e-01 3.13264682e-01 -2.58929834 0.08247013 43.25 -1.55572867e-01 -1.45782956e-01 2.13203160e-01 -2.38866929 0.03784735 43.50 -1.67102150e-01 -1.99764419e-01 2.60439919e-01 -2.26739823 0.05611667 43.75 -2.21303502e-01 -1.13690319e-01 2.48798570e-01 -2.66702122 0.04968994 44.00 -2.78124562e-01 -1.31093444e-01 3.07471564e-01 -2.70112827 0.07506875 44.25 -1.44006790e-01 -1.08668400e-01 1.80407252e-01 -2.49515017 0.02391806 44.50 -2.07181502e-01 -1.01915160e-01 2.30891478e-01 -2.68443599 0.03690228 44.75 -1.70631184e-01 -1.75095636e-01 2.44486161e-01 -2.34328197 0.04875819 45.00 -2.62562203e-01 -1.99364922e-01 3.29674510e-01 -2.49216258 0.09457300 45.25 -1.31081292e-01 -2.81039534e-01 3.10105667e-01 -2.00721750 0.08240791 45.50 -8.81353512e-02 -2.64195695e-01 2.78508896e-01 -1.89278573 0.07112723 45.75 -2.00110485e-01 -1.63835176e-01 2.58623609e-01 -2.45553870 0.04000550 46.00 -1.85435422e-01 -1.08929956e-01 2.15062853e-01 -2.61046857 0.02577853 46.25 -3.11926651e-01 4.65700087e-02 3.15383895e-01 2.99338938 0.06748658 46.50 -4.35807948e-01 -1.35417885e-02 4.36018288e-01 -3.11052981 0.13599052 46.75 -3.87675418e-01 3.82518292e-02 3.89557996e-01 3.04324127 0.10206770 47.00 -3.76010503e-01 2.32461772e-02 3.76728394e-01 3.07984803 0.09938769 47.25 -2.35459143e-01 6.21632104e-02 2.43526740e-01 2.88347361 0.04742352 47.50 -2.62461744e-01 -9.03002657e-02 2.77561354e-01 -2.81022727 0.05751056 47.75 -4.87982633e-01 -1.43955975e-02 4.88194923e-01 -3.11210098 0.20186172 48.00 -5.07748953e-01 1.43471551e-02 5.07951612e-01 3.11334377 0.20193027 48.25 -3.34879098e-01 1.39634103e-01 3.62824604e-01 2.74654421 0.09566489 48.50 -3.38823100e-01 1.51860959e-01 3.71298860e-01 2.72023552 0.10044139 48.75 2.96705791e-02 2.43956417e-01 2.45754098e-01 1.44976828 0.03798506 49.00 -5.68856514e-02 2.56106784e-01 2.62348361e-01 1.78936493 0.04406670 49.25 -2.47987608e-01 3.64423675e-01 4.40797537e-01 2.16830974 0.13852033 49.50 -1.51901472e-01 2.64872969e-01 3.05338741e-01 2.09149356 0.04374957 49.75 5.41830182e-01 -2.13046899e-01 5.82210381e-01 -0.37462943 0.06719101 50.00 4.69129941e-01 -6.08422619e-01 7.68284443e-01 -0.91395291 0.10799907 50.25 -1.56668885e-01 -6.33088230e-01 6.52185438e-01 -1.81339023 0.14930134 50.50 -3.16304537e-01 -3.29290491e-01 4.56596964e-01 -2.33608250 0.09987451 50.75 -3.21583843e-01 -1.81527696e-01 3.69281021e-01 -2.62770026 0.12412249 51.00 -2.89399699e-01 -1.22054745e-01 3.14085254e-01 -2.74247676 0.08453584 51.25 -2.49525602e-01 -1.15554442e-01 2.74983372e-01 -2.70790118 0.07574746 51.50 -2.06661170e-01 -9.90919779e-02 2.29190007e-01 -2.69448721 0.05620014 51.75 -1.72159996e-01 -1.49710979e-01 2.28150041e-01 -2.42582712 0.06975752 52.00 -1.47117978e-01 -1.87209558e-01 2.38098968e-01 -2.23684731 0.06897668 52.25 -1.70499592e-01 -1.61567983e-01 2.34892154e-01 -2.38308497 0.07996952 52.50 -1.98534142e-01 -1.76599668e-01 2.65712718e-01 -2.41459906 0.08206809 52.75 -1.75918707e-01 -7.51218349e-02 1.91286909e-01 -2.73800735 0.04930140 53.00 -1.33403848e-01 -9.99431334e-03 1.33777699e-01 -3.06681462 0.01996899 53.25 -6.20371482e-02 -8.79082712e-02 1.07594014e-01 -2.18533969 0.01116400 53.50 -1.17188129e-01 -1.21527237e-01 1.68825137e-01 -2.33801958 0.02254771 53.75 -2.05424442e-01 -9.87033727e-02 2.27906904e-01 -2.69367853 0.04909137 54.00 -4.98897310e-02 -1.99914780e-02 5.37461110e-02 -2.76047153 0.00270005 54.25 1.04394912e-01 -3.12028761e-02 1.08958327e-01 -0.29044061 0.01458071 54.50 -2.24692353e-02 -2.50549268e-01 2.51554770e-01 -1.66023697 0.08060042 54.75 -1.50108851e-01 -2.70018376e-01 3.08937842e-01 -2.07817394 0.13881571 55.00 -1.62043816e-01 -3.21481630e-01 3.60011995e-01 -2.03768117 0.11457153 55.25 -7.47065740e-02 -2.18498911e-01 2.30917402e-01 -1.90024433 0.06610564 55.50 1.38986157e-01 -2.75169830e-01 3.08278425e-01 -1.10308320 0.07075297 55.75 1.02334220e-01 -2.91456292e-01 3.08899761e-01 -1.23312993 0.06953145 56.00 -1.78051210e-01 -3.74421081e-01 4.14600264e-01 -2.01468300 0.18953993 56.25 -2.04839043e-01 -4.19833602e-01 4.67139473e-01 -2.02472145 0.23267580 56.50 -2.02897716e-01 -3.59130488e-01 4.12482958e-01 -2.08505963 0.14447092 56.75 -1.82222078e-01 -3.95696373e-01 4.35638044e-01 -2.00235580 0.17138842 57.00 -1.33763944e-01 -4.39478825e-01 4.59384839e-01 -1.86625699 0.20334060 57.25 -1.87066807e-01 -4.06046287e-01 4.47065519e-01 -2.00251527 0.17850191 57.50 5.94569773e-03 -3.84001574e-01 3.84047601e-01 -1.55531404 0.07825448 57.75 -3.56880232e-02 -4.48871511e-01 4.50287984e-01 -1.65013553 0.09900228 58.00 7.55878221e-02 -5.86786791e-01 5.91635240e-01 -1.44268533 0.15732238 58.25 4.38946467e-02 -8.87509601e-01 8.88594414e-01 -1.52137837 0.28290316 58.50 -3.21770011e-01 -1.19188593e+00 1.23455579e+00 -1.83447751 0.47885970 58.75 -6.79647563e-01 -1.30892122e+00 1.47485442e+00 -2.04971919 0.51041456 59.00 -1.86968824e+00 -1.34014508e+00 2.30037452e+00 -2.51969705 0.72680212 59.25 -2.00304690e+00 -7.16650657e-01 2.12738925e+00 -2.79800352 0.72596112 59.50 -1.42735349e+00 1.20139965e-01 1.43240064e+00 3.05762085 0.65964403 59.75 -1.14114259e+00 4.81583297e-03 1.14115275e+00 3.13737249 0.59386966 60.00 -9.03300769e-01 1.08914852e-02 9.03366429e-01 3.12953581 0.58689563 60.25 -6.14177162e-01 -2.43517433e-02 6.14659738e-01 -3.10196403 0.37292364 60.50 -3.90686113e-01 -2.72661724e-02 3.91636417e-01 -3.07191515 0.23618618 60.75 -2.96554968e-01 -1.07765382e-01 3.15528488e-01 -2.79303845 0.14972304 61.00 -1.74630723e-01 -2.43526214e-01 2.99667994e-01 -2.19290163 0.14704416 61.25 -2.13388757e-01 -4.16839938e-01 4.68284417e-01 -2.04393451 0.22275823 61.50 -3.63137130e-01 -5.68707214e-01 6.74756601e-01 -2.13906661 0.44433571 61.75 -4.75356831e-01 -5.57094299e-01 7.32337473e-01 -2.27719091 0.46850753 62.00 -5.15143191e-01 -7.19513152e-01 8.84913376e-01 -2.19215409 0.58153456 62.25 -5.35278020e-01 -6.36373994e-01 8.31561434e-01 -2.27012269 0.48582554 62.50 -6.40268080e-01 -6.60448404e-01 9.19856135e-01 -2.34068096 0.53635202 62.75 -7.19215015e-01 -6.40240868e-01 9.62901140e-01 -2.41422174 0.49780932 63.00 -8.75136467e-01 -6.28674797e-01 1.07754157e+00 -2.51864166 0.57123533 63.25 -1.11804679e+00 -4.53493458e-01 1.20651769e+00 -2.75625752 0.61474276 63.50 -1.35864508e+00 -2.70329737e-01 1.38527782e+00 -2.94518759 0.77212519 63.75 -1.27663870e+00 -2.55744177e-02 1.27689483e+00 -3.12156271 0.74927749 64.00 -1.09667090e+00 1.13636004e-01 1.10254261e+00 3.03834208 0.73753620 64.25 -8.82076423e-01 1.06080391e-01 8.88432251e-01 3.02190532 0.56814847 64.50 -8.34240557e-01 7.71644590e-02 8.37801684e-01 3.04935844 0.61046483 64.75 -5.44361844e-01 1.76455402e-01 5.72246736e-01 2.82812889 0.37273258 65.00 -4.60319362e-01 2.28835413e-01 5.14061826e-01 2.68024917 0.32535356 65.25 -3.31673239e-01 6.85510263e-02 3.38683305e-01 2.93778003 0.10168832 65.50 -2.93949526e-01 4.49940120e-02 2.97373140e-01 2.98970442 0.10817997 65.75 -1.41968573e-01 8.00746911e-02 1.62993963e-01 2.62804086 0.04396527 66.00 -5.38890913e-02 -3.11343702e-02 6.22365100e-02 -2.61769486 0.00978298 66.25 -1.65283918e-01 -1.42575736e-01 2.18281044e-01 -2.42982262 0.08895743 66.50 -1.59257530e-01 -2.31824358e-01 2.81256989e-01 -2.17272706 0.13440011 66.75 -1.16832260e-01 -2.03477264e-01 2.34633276e-01 -2.09201297 0.14462051 67.00 -8.63765781e-02 -2.09706615e-01 2.26798981e-01 -1.96151262 0.14830800 67.25 -1.83275074e-01 -4.06861538e-01 4.46235436e-01 -1.99403319 0.27061816 67.50 -3.09814295e-01 -4.44713580e-01 5.41991758e-01 -2.17927736 0.35813656 67.75 -1.48081943e-01 -4.93272093e-01 5.15020018e-01 -1.86243969 0.37762952 68.00 4.63107003e-02 -5.25254200e-01 5.27291813e-01 -1.48285556 0.35670753 68.25 4.02478802e-01 -1.02842797e+00 1.10437913e+00 -1.19776605 0.46845399 68.50 1.20216310e-01 -1.41523063e+00 1.42032732e+00 -1.48605508 0.43245788 68.75 -1.44311092e+00 -1.30944625e+00 1.94864533e+00 -2.40471655 0.60576873 69.00 -1.30298045e+00 -7.71144914e-01 1.51407481e+00 -2.60720103 0.62526513 69.25 -1.07507759e+00 -2.98012263e-01 1.11561782e+00 -2.87118162 0.74421872 69.50 -1.05827480e+00 -2.70091754e-01 1.09219737e+00 -2.89170813 0.78194494 69.75 -1.03040051e+00 -2.00683045e-01 1.04976136e+00 -2.94923850 0.84399528 70.00 -1.00373944e+00 -1.21248229e-01 1.01103610e+00 -3.02137859 0.83676560 70.25 -9.73642726e-01 -7.58495001e-02 9.76592702e-01 -3.06384687 0.86621458 70.50 -9.38777017e-01 -5.53614659e-02 9.40407985e-01 -3.08268897 0.82351029 70.75 -9.08619501e-01 7.55197021e-02 9.11752501e-01 3.05866848 0.82622313 71.00 -8.78958985e-01 1.54026590e-01 8.92352558e-01 2.96811654 0.73325942 71.25 -5.62339230e-01 2.62142762e-01 6.20438746e-01 2.70537768 0.53486239 71.50 -2.92712792e-01 1.24605548e-01 3.18130981e-01 2.73913587 0.15749237 71.75 -6.81204164e-02 -1.00540088e-01 1.21444227e-01 -2.16629220 0.04657272 72.00 -1.63682183e-01 -1.60183909e-01 2.29021269e-01 -2.36699568 0.12512868 72.25 -2.60165589e-01 -1.93600032e-01 3.24294783e-01 -2.50185149 0.35353242 72.50 -2.65234219e-01 -2.29316522e-01 3.50621246e-01 -2.42869412 0.39214559 72.75 -3.04591739e-01 -2.75736047e-01 4.10860676e-01 -2.40587666 0.57787411 73.00 -3.66950672e-01 -2.75470187e-01 4.58842696e-01 -2.49764314 0.62348011 73.25 -3.72090721e-01 -2.36186693e-01 4.40721747e-01 -2.57600877 0.65505719 73.50 -3.02326587e-01 -2.22756438e-01 3.75528688e-01 -2.50658847 0.59276741 73.75 -2.60677790e-01 -2.22832273e-01 3.42938962e-01 -2.43430768 0.65991931 74.00 -1.52595161e-01 -2.26134314e-01 2.72803980e-01 -2.16440775 0.50718675 74.25 -1.00697917e-01 -2.65140228e-01 2.83618426e-01 -1.93376084 0.51797096 74.50 -3.92738575e-02 -2.75818094e-01 2.78600173e-01 -1.71223597 0.37950710 74.75 2.80161542e-02 -2.95973278e-01 2.97296294e-01 -1.47641982 0.39197968 75.00 4.90762885e-02 -3.01134486e-01 3.05107294e-01 -1.40924525 0.23370791 75.25 1.98374754e-01 -2.03276597e-01 2.84031544e-01 -0.79760178 0.12228792 75.50 4.53156713e-01 -6.30346755e-01 7.76329851e-01 -0.94749765 0.38660895 75.75 5.49445744e-01 -8.06309887e-01 9.75718330e-01 -0.97264078 0.54240043 76.00 4.35297708e-01 -8.62599786e-01 9.66210373e-01 -1.10344791 0.32276754 76.25 3.61618483e-01 -1.10499448e+00 1.16266106e+00 -1.25452334 0.32554933 76.50 -3.68145733e-01 -6.60053471e-01 7.55778979e-01 -2.07957121 0.12134755 76.75 -9.55110479e-01 -5.80440095e-01 1.11765233e+00 -2.59551574 0.30320394 77.00 -8.60465899e-01 -1.60176928e-01 8.75247514e-01 -2.95754782 0.54227070 77.25 -6.45117458e-01 -1.31404937e-01 6.58364482e-01 -2.94065012 0.54436624 77.50 -2.23891530e-01 -5.04599656e-01 5.52040062e-01 -1.98839993 0.51576060 77.75 -9.23646953e-02 -7.29138535e-01 7.34965469e-01 -1.69680166 0.53413841 78.00 4.68181585e-02 -1.61500962e+00 1.61568809e+00 -1.54181504 0.69106543 78.25 1.42926934e-01 -2.08521864e+00 2.09011121e+00 -1.50236047 0.78347216 78.50 -4.45702755e-01 -2.53244784e+00 2.57136987e+00 -1.74500902 0.82710582 78.75 -7.55264777e-01 -2.37736014e+00 2.49444706e+00 -1.87840291 0.80395994 79.00 -1.14773822e+00 -1.99748380e+00 2.30374576e+00 -2.09232393 0.75566221 79.25 -1.20874347e+00 -1.89905902e+00 2.25110772e+00 -2.13761975 0.72964452 79.50 -1.58787244e+00 -2.04676276e+00 2.59047808e+00 -2.23060414 0.65120615 79.75 -1.59251568e+00 -1.99257796e+00 2.55077892e+00 -2.24506378 0.48951637 80.00 -1.60531202e+00 -1.76197696e+00 2.38360851e+00 -2.30970248 0.26512545 80.25 -1.90154262e+00 -1.85299373e-01 1.91054971e+00 -3.04445249 0.22590332 80.50 -1.71656528e+00 -1.32501440e-01 1.72167157e+00 -3.06455555 0.37400352 80.75 -1.71135444e+00 -3.11227710e-01 1.73942424e+00 -2.96169823 0.39505462 81.00 -1.29948290e+00 2.94971138e-01 1.33254035e+00 2.91838380 0.23951930 81.25 -7.52723728e-01 3.02700450e-01 8.11307939e-01 2.75924266 0.11244108 81.50 -7.73850649e-01 3.26221748e-01 8.39800843e-01 2.74264232 0.21155518 81.75 -6.89480302e-01 3.10869107e-01 7.56321815e-01 2.71801171 0.18589985 82.00 -5.15510880e-01 8.10084942e-02 5.21836990e-01 2.98572513 0.13192568 82.25 -5.28138117e-01 -1.76439453e-01 5.56830990e-01 -2.81917183 0.11243128 82.50 -6.05241576e-01 -3.99945132e-01 7.25447086e-01 -2.55766087 0.18729503 82.75 -8.76109941e-01 -2.58354608e-01 9.13408853e-01 -2.85483203 0.24711900 83.00 -1.12190340e+00 -1.25463493e-01 1.12889695e+00 -3.03022445 0.40433117 83.25 -1.04220360e+00 -2.85998476e-01 1.08073284e+00 -2.87376845 0.33556492 83.50 -1.07016544e+00 -1.74926801e-01 1.08436776e+00 -2.97956781 0.39870670 83.75 -1.13138581e+00 -6.13923446e-02 1.13305025e+00 -3.08738286 0.36089275 84.00 -1.09220825e+00 -1.24986017e-01 1.09933633e+00 -3.02765404 0.39833051 84.25 -1.01616860e+00 -2.14560753e-01 1.03857351e+00 -2.93350235 0.27794186 84.50 -1.35734750e+00 -1.39778049e-01 1.36452561e+00 -3.03897555 0.36646380 84.75 -1.15998841e+00 3.88794761e-01 1.22341100e+00 2.81818889 0.31830361 85.00 -1.09753392e+00 4.73162309e-01 1.19518336e+00 2.73455476 0.48266229 85.25 -9.16738001e-01 7.31224647e-02 9.19649639e-01 3.06199742 0.35908649 85.50 -1.01036819e+00 -8.27714189e-02 1.01375292e+00 -3.05985315 0.43385166 85.75 -1.13585925e+00 -1.29764143e-01 1.14324755e+00 -3.02784266 0.40103378 86.00 -1.26678614e+00 -3.96533763e-02 1.26740661e+00 -3.11030053 0.50842744 86.25 -7.69724069e-01 -2.47908117e-01 8.08661597e-01 -2.83000948 0.27666963 86.50 -8.03360505e-01 -2.15532363e-01 8.31770582e-01 -2.87947674 0.34609310 86.75 -1.01681685e+00 -2.45628100e-01 1.04606390e+00 -2.90456775 0.37870849 87.00 -1.19723638e+00 -4.12719917e-01 1.26637778e+00 -2.80962293 0.45422171 87.25 -1.34562571e+00 -3.90686476e-01 1.40119394e+00 -2.85902334 0.38372064 87.50 -1.43219204e+00 -1.81833086e-01 1.44368879e+00 -3.01530692 0.41662362 87.75 -1.30978014e+00 4.62735482e-01 1.38911776e+00 2.80198768 0.48636711 88.00 -1.27081376e+00 5.03826939e-01 1.36704396e+00 2.76414164 0.52837088 88.25 -1.29205843e+00 1.79070330e-01 1.30440836e+00 3.00387687 0.56493778 88.50 -1.32748339e+00 1.97640728e-02 1.32763051e+00 3.12670538 0.56425516 88.75 -1.31963641e+00 -1.50152987e-01 1.32815141e+00 -3.02829631 0.47225145 89.00 -1.36566345e+00 1.04853305e-01 1.36968276e+00 3.06496470 0.43970400 89.25 -1.13129799e+00 2.82864006e-01 1.16612486e+00 2.89658112 0.27722300 89.50 -1.05336413e+00 3.92002059e-03 1.05337143e+00 3.13787124 0.19555074 89.75 -9.78041135e-01 4.29062714e-01 1.06801651e+00 2.72817881 0.16117475 90.00 -3.78311150e-01 3.38350915e-01 5.07543759e-01 2.41189564 0.04142907 90.25 2.79492406e-01 2.43864897e-01 3.70925994e-01 0.71742810 0.04620974 90.50 -2.18030500e-01 1.88910641e-01 2.88486619e-01 2.42763064 0.05825282 90.75 -6.23551754e-01 3.32374625e-01 7.06604332e-01 2.65186798 0.48031278 91.00 -6.38802415e-01 4.56097233e-01 7.84916054e-01 2.52154036 0.42493112 91.25 -6.48734316e-01 3.98424085e-01 7.61313315e-01 2.59082929 0.41837772 91.50 -4.03088909e-01 2.15974560e-01 4.57302612e-01 2.64971780 0.18727496 91.75 -4.79117312e-01 1.79011663e-01 5.11467080e-01 2.78402534 0.51338085 92.00 -6.61876902e-01 2.10943468e-01 6.94678472e-01 2.83306487 0.75087493 92.25 -7.83524094e-01 2.57688869e-01 8.24811226e-01 2.82385145 0.83643707 92.50 -8.29520601e-01 3.64171371e-01 9.05938859e-01 2.72791194 0.76608311 92.75 -8.53587670e-01 4.97284649e-01 9.87878501e-01 2.61407911 0.73587470 93.00 -7.45936229e-01 5.83494274e-01 9.47040879e-01 2.47778091 0.56436912 93.25 -5.41599973e-01 8.87140927e-01 1.03939865e+00 2.11890102 0.63146428 93.50 -2.88364358e-01 7.62031007e-01 8.14766996e-01 1.93255806 0.52437652 93.75 -1.37755691e-01 6.75969484e-01 6.89863301e-01 1.77183326 0.64567839 94.00 -2.21513880e-01 4.65351165e-01 5.15383455e-01 2.01507204 0.50763765 94.25 -2.77824616e-01 3.31007850e-01 4.32148949e-01 2.26906284 0.56912733 94.50 -3.02738509e-01 3.59402450e-01 4.69915658e-01 2.27082563 0.49436300 94.75 -3.11720982e-01 3.57000302e-01 4.73940067e-01 2.28858738 0.57296656 95.00 -3.42437633e-01 4.37747861e-01 5.55775784e-01 2.23463328 0.54551716 95.25 -3.10247536e-01 4.79962205e-01 5.71504376e-01 2.14463658 0.54948710 95.50 -3.17985590e-01 3.53944899e-01 4.75806502e-01 2.30272908 0.49802673 95.75 -3.11481856e-01 2.99128718e-01 4.31855226e-01 2.37642253 0.56657244 96.00 -2.17800074e-01 2.88859913e-01 3.61769155e-01 2.21685186 0.38281020 96.25 -1.76644789e-01 3.18516871e-01 3.64220234e-01 2.07715314 0.42339170 96.50 -1.20551935e-01 3.87971005e-01 4.06268716e-01 1.87206246 0.39352527 96.75 8.23623981e-03 3.47499408e-01 3.47597000e-01 1.54709931 0.38966236 97.00 5.67764198e-02 2.85653288e-01 2.91241073e-01 1.37459345 0.40143963 97.25 7.70705840e-02 2.39936643e-01 2.52010849e-01 1.25999414 0.37655481 97.50 1.51366935e-01 1.92466575e-01 2.44857778e-01 0.90436723 0.34080339 97.75 1.90671410e-01 1.64026529e-01 2.51515981e-01 0.71041907 0.41892599 98.00 3.08048214e-01 1.66408496e-01 3.50122107e-01 0.49529024 0.55938563 98.25 4.15236311e-01 5.48851376e-02 4.18847910e-01 0.13141629 0.60343537 98.50 5.17632092e-01 -5.57899822e-02 5.20629911e-01 -0.10736477 0.75309263 98.75 6.33640829e-01 -1.55380021e-01 6.52413711e-01 -0.24047274 0.77764980 99.00 7.69054111e-01 -2.67801890e-01 8.14347640e-01 -0.33509036 0.79499431 99.25 9.25733155e-01 -3.84764163e-01 1.00250952e+00 -0.39390904 0.73660813 99.50 1.37324547e+00 -1.00233832e+00 1.70014271e+00 -0.63051558 0.82503860 99.75 1.40684128e+00 -1.43577540e+00 2.01013765e+00 -0.79557650 0.82067188 100.00 1.12547681e+00 -2.61111629e+00 2.84334773e+00 -1.16382695 0.81636696 100.25 5.67923407e-01 -3.41865305e+00 3.46550511e+00 -1.40617482 0.82228091 100.50 -1.41640093e+00 -3.56137047e+00 3.83269503e+00 -1.94932902 0.84590999 100.75 -2.17775430e+00 -2.78434722e+00 3.53485548e+00 -2.23455286 0.82983981 101.00 -2.58561363e+00 -1.45139828e+00 2.96512306e+00 -2.63008778 0.92067892 101.25 -2.52569779e+00 -1.11147352e+00 2.75944246e+00 -2.72703055 0.93353673 101.50 -2.30349773e+00 -7.40077682e-01 2.41946622e+00 -2.83072513 0.94272834 101.75 -2.12632280e+00 -5.55891647e-01 2.19778620e+00 -2.88588249 0.93863985 102.00 -1.87847444e+00 -4.63690835e-01 1.93485798e+00 -2.89958620 0.96172927 102.25 -1.77793265e+00 -4.14773381e-01 1.82567288e+00 -2.91240210 0.96256230 102.50 -1.71959799e+00 -3.80059497e-01 1.76109695e+00 -2.92407300 0.98120769 102.75 -1.68632771e+00 -3.80460575e-01 1.72871380e+00 -2.91969306 0.97621137 103.00 -1.66900537e+00 -3.60551088e-01 1.70750579e+00 -2.92883458 0.98421103 103.25 -1.66403536e+00 -3.36548649e-01 1.69772750e+00 -2.94203602 0.98046062 103.50 -1.63826644e+00 -3.03070189e-01 1.66606377e+00 -2.95866626 0.98788941 103.75 -1.62712463e+00 -2.98565805e-01 1.65429021e+00 -2.96011851 0.98435562 104.00 -1.62708783e+00 -3.35236109e-01 1.66126399e+00 -2.93840155 0.99142998 104.25 -1.66980136e+00 -3.67613733e-01 1.70978842e+00 -2.92489530 0.98722866 104.50 -1.76630834e+00 -3.82357241e-01 1.80721947e+00 -2.92840945 0.98709428 104.75 -1.89503438e+00 -3.09312422e-01 1.92011184e+00 -2.97979683 0.98434386 105.00 -1.98972730e+00 -2.01029082e-01 1.99985685e+00 -3.04090085 0.98595976 105.25 -1.97835103e+00 -7.59292861e-02 1.97980758e+00 -3.10323139 0.98444121 105.50 -1.97760501e+00 -3.79677519e-02 1.97796945e+00 -3.12239616 0.98932993 105.75 -2.02231926e+00 3.23427845e-02 2.02257788e+00 3.12560110 0.98308883 106.00 -2.03873423e+00 8.32515874e-02 2.04043331e+00 3.10078039 0.99087734 106.25 -2.09364994e+00 1.04822940e-01 2.09627239e+00 3.09156735 0.99002050 106.50 -2.16593423e+00 1.45777917e-01 2.17083447e+00 3.07438914 0.99023310 106.75 -2.39032208e+00 2.92516317e-01 2.40815395e+00 3.01982283 0.97881224 107.00 -2.47745371e+00 5.05148347e-01 2.52842871e+00 2.94045165 0.97834675 107.25 -2.29209681e+00 8.44112531e-01 2.44258751e+00 2.78873449 0.96903122 107.50 -2.23444604e+00 9.44173466e-01 2.42573961e+00 2.74179586 0.97806484 107.75 -2.29483752e+00 1.12933848e+00 2.55767173e+00 2.68426783 0.95960325 108.00 -2.27798248e+00 1.38705750e+00 2.66704569e+00 2.59465665 0.95827995 108.25 -2.10160362e+00 1.78730930e+00 2.75884257e+00 2.43683726 0.93380852 108.50 -1.76214214e+00 2.10342873e+00 2.74400389e+00 2.26813403 0.92322192 108.75 -1.10946068e+00 2.27392648e+00 2.53014716e+00 2.02472141 0.93195233 109.00 -8.29038634e-01 2.29903004e+00 2.44394030e+00 1.91688620 0.93673962 109.25 -4.07374979e-01 2.10394885e+00 2.14302476e+00 1.76205366 0.91974063 109.50 -1.51268755e-01 2.00130755e+00 2.00701623e+00 1.64623784 0.90732444 109.75 1.69055943e-01 1.59222906e+00 1.60117872e+00 1.46501699 0.74611988 110.00 7.67958447e-02 1.13745427e+00 1.14004378e+00 1.50338309 0.42974724 110.25 1.29934514e-01 2.04436230e+00 2.04848729e+00 1.50732422 0.56187534 110.50 7.60936018e-01 1.80295774e+00 1.95695688e+00 1.17142809 0.65495144 110.75 9.71837901e-01 8.57083976e-01 1.29578619e+00 0.72273628 0.80538801 111.00 9.00738838e-01 6.63061029e-01 1.11847234e+00 0.63456516 0.79515088 111.25 7.73138663e-01 3.00290067e-01 8.29407931e-01 0.37046994 0.64319110 111.50 7.11562357e-01 1.59774265e-01 7.29279647e-01 0.22087664 0.50326043 111.75 5.46203914e-01 1.11594022e-01 5.57487167e-01 0.20153475 0.35971933 112.00 4.76082560e-01 -1.04518384e-01 4.87420452e-01 -0.21610993 0.24534298 112.25 4.60109632e-01 -2.66012468e-01 5.31472960e-01 -0.52419850 0.37839139 112.50 4.26719967e-01 -2.99524862e-01 5.21349281e-01 -0.61201588 0.30998012 112.75 4.26121805e-01 -4.70500362e-01 6.34783730e-01 -0.83485307 0.46796090 113.00 2.90194712e-01 -8.40100139e-01 8.88808874e-01 -1.23819971 0.53233763 113.25 -9.25468438e-02 -1.18158052e+00 1.18519932e+00 -1.64896137 0.76025794 113.50 -3.01350805e-01 -1.05967837e+00 1.10169441e+00 -1.84786150 0.73604601 113.75 -5.69642357e-01 -8.96463613e-01 1.06213908e+00 -2.13686271 0.79281770 114.00 -6.13760802e-01 -7.43486223e-01 9.64092364e-01 -2.26090415 0.79709852 114.25 -6.08484695e-01 -6.55766094e-01 8.94585264e-01 -2.31881316 0.85153350 114.50 -5.22040704e-01 -6.19765138e-01 8.10330379e-01 -2.27081495 0.67635782 114.75 -3.66961109e-01 -6.23233135e-01 7.23242695e-01 -2.10294154 0.54540811 115.00 -3.75168915e-01 -8.25691335e-01 9.06927723e-01 -1.99727794 0.57515029 115.25 -3.56749543e-01 -1.01114053e+00 1.07222918e+00 -1.90998025 0.68770110 115.50 -4.52572172e-01 -1.28155810e+00 1.35912205e+00 -1.91026763 0.70561478 115.75 -6.34152185e-01 -1.50608665e+00 1.63414993e+00 -1.96932466 0.71054858 116.00 -1.45949177e+00 -1.77571408e+00 2.29853795e+00 -2.25875989 0.76303638 116.25 -2.00019059e+00 -1.60588756e+00 2.56508036e+00 -2.46510582 0.84449162 116.50 -2.40466204e+00 -7.21171509e-01 2.51047562e+00 -2.85022251 0.84638654 116.75 -2.55618161e+00 -2.30440433e-01 2.56654773e+00 -3.05168543 0.85266730 117.00 -1.42636655e+00 7.76272646e-01 1.62392141e+00 2.64318954 0.45644700 117.25 -5.44082220e-01 4.30168346e-01 6.93592292e-01 2.47259060 0.18409464 117.50 -1.03216485e+00 -7.35967763e-01 1.26768010e+00 -2.52217305 0.53810659 117.75 -1.60227838e+00 -1.07943706e+00 1.93196283e+00 -2.54874429 0.84257663 118.00 -2.55184744e+00 -8.26708984e-01 2.68241926e+00 -2.82829726 0.88276562 118.25 -2.92378175e+00 -4.85978053e-01 2.96389513e+00 -2.97688291 0.90229723 118.50 -3.05929934e+00 1.08803162e+00 3.24701790e+00 2.79989570 0.80970095 118.75 -2.38454780e+00 2.04604267e+00 3.14203100e+00 2.43244816 0.82358259 119.00 -9.91222085e-01 1.88220594e+00 2.12725655e+00 2.05551860 0.74055336 119.25 -5.98644061e-01 1.48316082e+00 1.59941887e+00 1.95442569 0.76159285 119.50 -3.36440899e-01 1.48701712e+00 1.52460238e+00 1.79330231 0.79107255 119.75 -2.09749763e-01 1.29981132e+00 1.31662616e+00 1.73078651 0.71867254 120.00 -1.63235814e-01 1.06029680e+00 1.07278853e+00 1.72354997 0.57007457 120.25 -1.22303945e-01 9.05519678e-01 9.13741836e-01 1.70504881 0.45028649 120.50 -3.52197500e-01 9.93311734e-01 1.05390288e+00 1.91153567 0.48412642 120.75 -4.07409354e-01 1.12143808e+00 1.19314951e+00 1.91926305 0.44407681 121.00 -2.95930761e-01 1.74169842e+00 1.76666023e+00 1.73909833 0.60128667 121.25 -2.55965645e-02 2.02872958e+00 2.02889105e+00 1.58341270 0.53324292 121.50 1.86213363e+00 2.87723111e+00 3.42724387e+00 0.99639452 0.60087775 121.75 3.34553942e+00 2.50375807e+00 4.17868861e+00 0.64246796 0.70841924 122.00 3.88932701e+00 1.82408341e+00 4.29582878e+00 0.43853920 0.84373521 122.25 4.60259818e+00 1.48235018e+00 4.83541850e+00 0.31157784 0.83176994 122.50 5.67775806e+00 7.70927817e-01 5.72985744e+00 0.13495500 0.79300495 122.75 7.93140016e+00 -2.67548233e-01 7.93591145e+00 -0.03372000 0.74411002 123.00 1.10221019e+01 -4.08512986e+00 1.17547870e+01 -0.35493460 0.75318912 123.25 8.12439343e+00 -1.00607073e+01 1.29314964e+01 -0.89147652 0.65705615 123.50 5.18378168e-01 -1.12483905e+01 1.12603288e+01 -1.52474426 0.74871021 123.75 -7.32671690e-01 -8.13398556e+00 8.16691673e+00 -1.66062926 0.60462120 124.00 2.63207246e-01 -5.58616034e+00 5.59235777e+00 -1.52371341 0.57733767 124.25 1.47937180e+00 -5.25724534e+00 5.46142559e+00 -1.29649288 0.55014313 124.50 3.86556793e+00 -6.49815299e+00 7.56099251e+00 -1.03415610 0.57096962 124.75 1.67546205e+00 -8.05677290e+00 8.22914107e+00 -1.36576168 0.38226402 125.00 -5.10122421e+00 -1.23380450e+01 1.33510241e+01 -1.96284761 0.62441399 125.25 -5.94205181e+00 -1.00534301e+01 1.16781606e+01 -2.10460689 0.66893712 125.50 -6.31486559e+00 -1.01723028e+01 1.19730226e+01 -2.12636262 0.71445307 125.75 -5.92833138e+00 -7.94096142e+00 9.90979219e+00 -2.21208631 0.68295679 126.00 -6.11359242e+00 -8.29449068e+00 1.03041054e+01 -2.20596857 0.76889861 126.25 -5.91523218e+00 -8.07848520e+00 1.00125868e+01 -2.20282109 0.63679040 126.50 -6.45593510e+00 -8.49923037e+00 1.06731446e+01 -2.22040719 0.63983726 126.75 -5.94957394e+00 -8.02047968e+00 9.98626679e+00 -2.20902731 0.61432281 127.00 -4.46619530e+00 -7.84970405e+00 9.03132073e+00 -2.08808220 0.55359821 127.25 -4.68353325e+00 -5.31714937e+00 7.08572940e+00 -2.29292177 0.36745239 127.50 -5.77444524e+00 -7.02821300e+00 9.09615280e+00 -2.25857549 0.42511857 127.75 -5.58059984e+00 -7.78839291e+00 9.58134431e+00 -2.19252885 0.53043411 128.00 -5.51120362e+00 -8.09446785e+00 9.79253671e+00 -2.16856118 0.60028466 128.25 -3.30534607e+00 -7.40136121e+00 8.10589048e+00 -1.99080774 0.67823959 128.50 -2.83521980e+00 -7.23322978e+00 7.76904655e+00 -1.94436246 0.77274295 128.75 -9.47616540e-01 -6.20094090e+00 6.27292955e+00 -1.72244130 0.77691636 129.00 -3.06971268e-01 -6.14082289e+00 6.14849064e+00 -1.62074337 0.78240255 129.25 8.23012815e-01 -5.71292249e+00 5.77190033e+00 -1.42771909 0.65236117 129.50 1.25648440e+00 -5.46192193e+00 5.60458243e+00 -1.34468580 0.61909669 129.75 2.39087904e+00 -6.18186350e+00 6.62810221e+00 -1.20175819 0.63739620 130.00 2.52045266e+00 -7.72681548e+00 8.12750632e+00 -1.25548349 0.66341643 130.25 2.71306658e+00 -9.91537578e+00 1.02798544e+01 -1.30371153 0.75339208 130.50 1.55735804e+00 -1.19748428e+01 1.20756873e+01 -1.44146971 0.77748721 130.75 -2.53859171e+00 -1.36462204e+01 1.38803378e+01 -1.75472279 0.62005186 131.00 -6.94256498e+00 -1.07806780e+01 1.28227230e+01 -2.14292949 0.54406060 131.25 -8.54800789e+00 -2.89240384e+00 9.02410322e+00 -2.81531446 0.58064742 131.50 -6.54467964e+00 -2.19661702e+00 6.90347434e+00 -2.81777293 0.67097297 131.75 -4.98003783e+00 -3.14567122e+00 5.89033312e+00 -2.57822125 0.81665707 132.00 -4.72983485e+00 -2.82232053e+00 5.50788806e+00 -2.60359878 0.75576004 132.25 -5.91393536e+00 -2.46894929e+00 6.40861467e+00 -2.74610878 0.80375124 132.50 -5.87647755e+00 -1.39991206e+00 6.04092230e+00 -2.90772858 0.76862117 132.75 -4.71147158e+00 -5.96379125e-01 4.74906649e+00 -3.01568205 0.78641700 133.00 -5.10142388e+00 -8.42671384e-01 5.17055322e+00 -2.97788734 0.87541364 133.25 -5.18904621e+00 -4.16424441e-01 5.20572857e+00 -3.06151360 0.92191845 133.50 -4.86453221e+00 -3.49085784e-03 4.86453346e+00 -3.14087504 0.92677960 133.75 -4.78135949e+00 4.89616471e-01 4.80636275e+00 3.03954724 0.95126309 134.00 -4.45392990e+00 1.03151534e+00 4.57181753e+00 2.91400834 0.94981576 134.25 -4.12735583e+00 1.20629769e+00 4.30002561e+00 2.85724363 0.97580891 134.50 -4.26728385e+00 1.15101085e+00 4.41978930e+00 2.87813328 0.97366303 134.75 -4.44487585e+00 1.54344911e+00 4.70522650e+00 2.80737665 0.98087287 135.00 -4.30604631e+00 2.30021847e+00 4.88190945e+00 2.65097374 0.97131408 135.25 -4.30764264e+00 2.94922016e+00 5.22050617e+00 2.54124433 0.98145297 135.50 -3.87121326e+00 3.66808528e+00 5.33302370e+00 2.38313053 0.95972875 135.75 -3.06532802e+00 4.68111837e+00 5.59545396e+00 2.15055818 0.95436920 136.00 -1.97049854e+00 5.44235710e+00 5.78810118e+00 1.91818065 0.94215011 136.25 -1.04975692e+00 5.62375052e+00 5.72088800e+00 1.75533743 0.96328008 136.50 3.12049460e-02 5.99300206e+00 5.99308330e+00 1.56558948 0.94829513 136.75 7.86927611e-01 6.27501924e+00 6.32416963e+00 1.44604120 0.97045284 137.00 1.59933015e+00 6.28408188e+00 6.48440761e+00 1.32158219 0.95534388 137.25 2.33128149e+00 6.45461344e+00 6.86271870e+00 1.22419594 0.96833137 137.50 3.48409962e+00 6.97614355e+00 7.79779001e+00 1.10760433 0.95406604 137.75 4.37463077e+00 7.63722579e+00 8.80139830e+00 1.05061423 0.96053691 138.00 6.86686399e+00 8.60676045e+00 1.10104562e+01 0.89737056 0.92867621 138.25 8.52668667e+00 9.04711189e+00 1.24319998e+01 0.81500321 0.94556910 138.50 1.14992620e+01 8.76550239e+00 1.44591514e+01 0.65130557 0.84915600 138.75 1.46707788e+01 5.21660783e+00 1.55706374e+01 0.34163552 0.85417090 139.00 1.55649531e+01 2.18083150e+00 1.57169905e+01 0.13920546 0.89304152 139.25 1.75720507e+01 4.55721740e-01 1.75779592e+01 0.02592865 0.91005292 139.50 2.11580770e+01 -2.22182249e-01 2.11592435e+01 -0.01050067 0.88928628 139.75 2.30589932e+01 -3.37991224e+00 2.33053851e+01 -0.14554035 0.87222933 140.00 2.14252333e+01 -1.30144144e+01 2.50682190e+01 -0.54586773 0.85300951 140.25 2.15044991e+01 -1.77777796e+01 2.79014861e+01 -0.69081101 0.87298625 140.50 1.60578904e+01 -2.53757714e+01 3.00297455e+01 -1.00660480 0.86882150 140.75 1.52025411e+01 -3.05793998e+01 3.41499187e+01 -1.10943151 0.89040366 141.00 6.50968203e+00 -3.45795916e+01 3.51869879e+01 -1.38472188 0.88084989 141.25 -1.49680582e+00 -3.29027039e+01 3.29367325e+01 -1.61625686 0.84526498 141.50 -1.30268870e+01 -2.11774664e+01 2.48633238e+01 -2.12226634 0.80439786 141.75 -1.32517072e+01 -1.28693905e+01 1.84723836e+01 -2.37082976 0.72528565 142.00 -8.19578902e+00 -6.82234478e+00 1.06637398e+01 -2.44739320 0.74795388 142.25 -5.48677490e+00 -5.57871989e+00 7.82475651e+00 -2.34788552 0.63969994 142.50 -1.04568323e+00 -3.30212418e+00 3.46373750e+00 -1.87747556 0.33182262 142.75 1.06788400e+00 -3.64700173e+00 3.80013129e+00 -1.28594748 0.27590020 143.00 6.05127233e+00 -5.42114980e+00 8.12445457e+00 -0.73052832 0.55895521 143.25 7.32131138e+00 -6.08072484e+00 9.51718524e+00 -0.69309418 0.62510686 143.50 8.85939056e+00 -6.23914540e+00 1.08358542e+01 -0.61356656 0.61014985 143.75 1.06661265e+01 -8.44894396e+00 1.36070169e+01 -0.66992285 0.66875807 144.00 1.57915706e+01 -1.01063996e+01 1.87486803e+01 -0.56930395 0.73216599 144.25 1.77043484e+01 -1.21305362e+01 2.14614506e+01 -0.60070529 0.67544164 144.50 1.95277437e+01 -1.74128721e+01 2.61637323e+01 -0.72821001 0.70296786 144.75 1.84227710e+01 -1.91174290e+01 2.65494742e+01 -0.80390043 0.63617878 145.00 2.03383344e+01 -2.61274471e+01 3.31102905e+01 -0.90934819 0.61763406 145.25 2.20400810e+01 -3.59148322e+01 4.21383476e+01 -1.02038137 0.69605664 145.50 2.11525474e+01 -4.09800999e+01 4.61172294e+01 -1.09429946 0.71961030 145.75 9.04817160e+00 -4.42884862e+01 4.52033120e+01 -1.36926886 0.65829628 146.00 -3.90374880e+00 -5.16662607e+01 5.18135286e+01 -1.64621006 0.76292985 146.25 -7.17393410e+00 -5.92316376e+01 5.96644972e+01 -1.69132585 0.84887099 146.50 -6.30430603e+00 -6.49115723e+01 6.52169955e+01 -1.66761413 0.90125989 146.75 -8.11467065e+00 -6.84236949e+01 6.89031923e+01 -1.68883943 0.90989104 147.00 -6.74373025e+00 -7.26077198e+01 7.29202227e+01 -1.66340960 0.89613460 147.25 -1.43638994e+01 -6.60374470e+01 6.75815508e+01 -1.78497171 0.74564067 147.50 -3.61581771e+01 -6.70852179e+01 7.62091873e+01 -2.06514631 0.70196774 147.75 -3.73624122e+01 -4.41666278e+01 5.78501587e+01 -2.27292988 0.56761864 148.00 -3.28580083e+01 -3.14008153e+01 4.54495315e+01 -2.37886754 0.51728974 148.25 -2.35573633e+01 -1.83756961e+01 2.98766727e+01 -2.47914122 0.33312813 148.50 -2.36797287e+01 -1.83254063e+01 2.99424459e+01 -2.48297905 0.48498033 148.75 -2.03073548e+01 -2.28060631e+01 3.05369477e+01 -2.29830262 0.55992507 149.00 -1.92545376e+01 -2.20607306e+01 2.92816163e+01 -2.28837720 0.56457835 149.25 -1.34127638e+01 -1.88844449e+01 2.31629983e+01 -2.18837147 0.38651214 149.50 -1.21123721e+01 -1.75306073e+01 2.13080209e+01 -2.17540712 0.42270159 149.75 -7.50693399e+00 -1.93307933e+01 2.07372521e+01 -1.94121136 0.52239331 150.00 -5.79094608e+00 -2.03298370e+01 2.11385271e+01 -1.84829638 0.60869072 150.25 -1.92829059e+00 -1.51533135e+01 1.52755103e+01 -1.69736813 0.41979461 150.50 1.67935074e+00 -1.42973201e+01 1.43956098e+01 -1.45387295 0.32590717 150.75 3.07007295e+00 -1.06808694e+01 1.11133397e+01 -1.29090505 0.23822409 151.00 4.13311550e+00 -9.55861356e+00 1.04139203e+01 -1.16267710 0.21478946 151.25 6.49477585e+00 -1.21669828e+01 1.37919391e+01 -1.08047316 0.30851861 151.50 7.04527446e+00 -1.09842786e+01 1.30495314e+01 -1.00049328 0.28991419 151.75 3.80747824e+00 -1.02056216e+01 1.08927317e+01 -1.21371302 0.18670409 152.00 3.79805698e+00 -1.15333427e+01 1.21426204e+01 -1.25267020 0.21487146 152.25 1.02570459e+01 -8.29142399e+00 1.31891888e+01 -0.67982002 0.25974021 152.50 1.15024520e+01 -4.27393382e+00 1.22708155e+01 -0.35575770 0.20888457 152.75 7.92998001e+00 3.18544211e+00 8.54585423e+00 0.38196768 0.10960883 153.00 3.95134636e+00 -2.55105162e-01 3.95957280e+00 -0.06447210 0.03319956 153.25 1.05390149e+01 -1.04858763e+00 1.05910515e+01 -0.09916941 0.27417313 153.50 1.00732152e+01 -2.65267064e+00 1.04166370e+01 -0.25749310 0.25110601 153.75 4.83574430e+00 -7.09936364e+00 8.58984208e+00 -0.97283248 0.15469325 154.00 6.44068701e+00 -8.41855097e+00 1.05997382e+01 -0.91772700 0.27435772 154.25 1.21825603e+01 -9.06642917e+00 1.51860104e+01 -0.63978763 0.50317982 154.50 1.24306491e+01 -7.52420608e+00 1.45304754e+01 -0.54430357 0.56828018 154.75 1.21466861e+01 -5.58964403e+00 1.33710921e+01 -0.43128607 0.60068567 155.00 1.23152608e+01 -4.29753116e+00 1.30435586e+01 -0.33574785 0.56406382 155.25 1.22291467e+01 -4.36261269e+00 1.29840063e+01 -0.34266566 0.61588045 155.50 1.12247215e+01 -3.95197845e+00 1.19001053e+01 -0.33852492 0.47520851 155.75 1.21043904e+01 -3.24814127e+00 1.25326250e+01 -0.26216777 0.50113912 156.00 9.73037278e+00 -1.66544061e+00 9.87187150e+00 -0.16951636 0.37379857 156.25 1.10735722e+01 -1.36233264e-01 1.10744102e+01 -0.01230194 0.48072599 156.50 1.26463023e+01 -3.26415262e-01 1.26505141e+01 -0.02580539 0.57395434 156.75 1.32979842e+01 -1.07699028e-01 1.32984203e+01 -0.00809872 0.55336553 157.00 1.09051040e+01 1.21103307e+00 1.09721418e+01 0.11059878 0.40870390 157.25 1.27976153e+01 1.60424484e+00 1.28977734e+01 0.12470450 0.52086346 157.50 1.20598994e+01 2.45719153e-01 1.20624024e+01 0.02037207 0.41674227 157.75 1.00535364e+01 -2.21946031e+00 1.02956106e+01 -0.21727905 0.34508406 158.00 1.04687386e+01 -2.10153411e+00 1.06775903e+01 -0.19811062 0.39283600 158.25 1.22952824e+01 -1.54168801e+00 1.23915605e+01 -0.12473758 0.51824793 158.50 1.05154942e+01 -9.62089552e-01 1.05594145e+01 -0.09123855 0.50325420 158.75 1.15064293e+01 -1.21122472e+00 1.15700035e+01 -0.10487880 0.47369899 159.00 9.90684997e+00 1.04038696e+00 9.96132930e+00 0.10463340 0.36771408 159.25 8.72096354e+00 2.35136767e+00 9.03239365e+00 0.26335992 0.32624753 159.50 8.04126190e+00 2.39743914e-01 8.04483499e+00 0.02980539 0.33586844 159.75 8.86011221e+00 -1.45576453e+00 8.97891078e+00 -0.16285038 0.38666236 160.00 7.32597981e+00 -2.42068746e+00 7.71554975e+00 -0.31913085 0.35583178 160.25 8.31013767e+00 -1.86598662e+00 8.51705901e+00 -0.22087981 0.40220024 160.50 9.17432859e+00 -1.07772903e+00 9.23741333e+00 -0.11693632 0.45529984 160.75 9.64243378e+00 -8.31853218e-01 9.67824927e+00 -0.08605698 0.50804217 161.00 9.77629550e+00 9.94535583e-01 9.82675199e+00 0.10138052 0.46945615 161.25 1.07864625e+01 1.16646320e+00 1.08493507e+01 0.10772278 0.49759637 161.50 1.01414364e+01 7.88440397e-01 1.01720387e+01 0.07758838 0.45834182 161.75 9.77324974e+00 1.96148118e+00 9.96814019e+00 0.19806756 0.40846487 162.00 1.01690453e+01 2.87807554e+00 1.05684815e+01 0.27580989 0.43575177 162.25 1.00685717e+01 1.50252722e+00 1.01800650e+01 0.14813625 0.38740872 162.50 1.21718424e+01 -1.76542610e+00 1.22992064e+01 -0.14403737 0.52421572 162.75 1.28810909e+01 -4.43331851e-01 1.28887178e+01 -0.03440368 0.53340133 163.00 1.63976991e+01 -8.37999369e-01 1.64190980e+01 -0.05106027 0.71419438 163.25 1.70841739e+01 -2.34994510e+00 1.72450352e+01 -0.13669321 0.71928765 163.50 1.69234704e+01 -4.25292333e+00 1.74496764e+01 -0.24620489 0.65030542 163.75 1.12650467e+01 -3.88573783e+00 1.19163852e+01 -0.33215776 0.43768442 164.00 8.57625388e+00 -1.48531171e+00 8.70392334e+00 -0.17148781 0.25816682 164.25 6.19366294e+00 -1.63715502e+00 6.40638254e+00 -0.25841719 0.21461995 164.50 6.87075085e+00 -2.64482868e+00 7.36222357e+00 -0.36745682 0.29659539 164.75 5.61478262e+00 -2.45978834e+00 6.12995453e+00 -0.41290678 0.21468908 165.00 5.02504569e+00 -2.24023678e+00 5.50179471e+00 -0.41936757 0.18808031 165.25 3.85199994e+00 -2.14734135e+00 4.41009959e+00 -0.50855369 0.13545532 165.50 3.14704335e+00 -8.57786851e-01 3.26185225e+00 -0.26610484 0.07070591 165.75 2.16441068e+00 -1.17163611e+00 2.46117955e+00 -0.49615373 0.04824583 166.00 8.36823289e-01 -1.74221518e+00 1.93276666e+00 -1.12301514 0.03048319 166.25 1.04246043e+00 -1.81256954e+00 2.09096439e+00 -1.04886547 0.04380583 166.50 -2.83992869e-01 -2.94181182e+00 2.95548790e+00 -1.66703483 0.07452131 166.75 -1.77492010e-02 -3.24216796e+00 3.24221655e+00 -1.57627076 0.11600478 167.00 -4.56579839e-01 -3.16863412e+00 3.20136024e+00 -1.71390488 0.13320845 167.25 -3.25870496e-01 -3.66300832e+00 3.67747489e+00 -1.65952527 0.14726005 167.50 -3.94882789e-01 -5.01389635e+00 5.02942234e+00 -1.64939176 0.18897214 167.75 -2.35453429e-01 -3.92500157e+00 3.93205743e+00 -1.63071264 0.15626920 168.00 -1.34447556e+00 -3.92541718e+00 4.14927880e+00 -1.90077867 0.17167504 168.25 -1.81939961e+00 -3.28808749e+00 3.75788960e+00 -2.07619307 0.19101576 168.50 -3.57002149e+00 -3.26647413e+00 4.83889519e+00 -2.40056636 0.32832905 168.75 -2.84655770e+00 -2.73465630e+00 3.94730741e+00 -2.37624146 0.42773897 169.00 -2.26597744e+00 -2.78848111e+00 3.59308790e+00 -2.25318557 0.59861656 169.25 -1.50806053e+00 -2.19500568e+00 2.66313660e+00 -2.17277243 0.60209373 169.50 -1.11362240e+00 -1.87713102e+00 2.18260755e+00 -2.10624349 0.65486546 169.75 -6.62577320e-01 -1.48586163e+00 1.62689689e+00 -1.99025321 0.55654910 170.00 -2.04182525e-01 -1.05591124e+00 1.07547155e+00 -1.76180972 0.41301442 170.25 4.50149267e-01 -3.29491250e-01 5.57851993e-01 -0.63185518 0.17823325 170.50 6.50217336e-01 7.06189296e-02 6.54040991e-01 0.10818415 0.26541524 170.75 1.32134766e+00 1.53152281e+00 2.02275104e+00 0.85893678 0.49970562 171.00 1.71917902e+00 2.64852022e+00 3.15756803e+00 0.99504754 0.57656126 171.25 7.96166512e-01 2.10152929e+00 2.24728870e+00 1.20865370 0.11389357 171.50 -8.17839714e-02 3.80726989e-01 3.89411938e-01 1.78239089 0.00250655 171.75 -2.64687255e-01 -1.88393046e+00 1.90243353e+00 -1.71038003 0.07526786 172.00 3.96472620e-01 -2.77157063e+00 2.79978468e+00 -1.42871047 0.19046613 172.25 5.39456254e-01 -3.41783292e+00 3.46014377e+00 -1.41425199 0.31170546 172.50 5.60435811e-01 -3.34461670e+00 3.39124596e+00 -1.40477514 0.33310794 172.75 2.14965088e+00 -3.00618288e+00 3.69569133e+00 -0.95002338 0.39289373 173.00 2.20869359e+00 -2.92864774e+00 3.66814735e+00 -0.92463277 0.36924064 173.25 2.51053735e+00 -3.79668402e+00 4.55165984e+00 -0.98655676 0.44552230 173.50 2.55848711e+00 -3.27475891e+00 4.15570719e+00 -0.90757784 0.38988530 173.75 2.05152715e+00 -2.87999001e+00 3.53597315e+00 -0.95183754 0.27692660 174.00 1.13179009e+00 -2.93442877e+00 3.14512655e+00 -1.20268365 0.23244112 174.25 -4.99891253e-01 -3.02777976e+00 3.06876874e+00 -1.73442184 0.39241769 174.50 -1.38373453e-01 -2.89942548e+00 2.90272550e+00 -1.61848458 0.45354391 174.75 3.81412190e-01 -2.77509336e+00 2.80118161e+00 -1.43421086 0.54938548 175.00 8.19807610e-01 -2.73439875e+00 2.85464902e+00 -1.27951133 0.47686262 175.25 1.15412203e+00 -2.82029438e+00 3.04730341e+00 -1.18236668 0.55462508 175.50 1.37472308e+00 -2.53138309e+00 2.88058395e+00 -1.07328773 0.46644604 175.75 1.83370219e+00 -2.44668802e+00 3.05757191e+00 -0.92763897 0.57241756 176.00 2.09388372e+00 -2.17582930e+00 3.01969902e+00 -0.80458810 0.49673128 176.25 2.42032365e+00 -2.28263139e+00 3.32691639e+00 -0.75612871 0.46900873 176.50 1.95355939e+00 -2.28689611e+00 3.00770479e+00 -0.86384555 0.37262727 176.75 1.06190395e+00 -2.73329016e+00 2.93232248e+00 -1.20023630 0.41786100 177.00 1.24826943e+00 -2.58372011e+00 2.86945747e+00 -1.12073659 0.35878214 177.25 1.85327131e+00 -3.14291486e+00 3.64863377e+00 -1.03800971 0.52879636 177.50 1.40821650e+00 -3.64459106e+00 3.90718795e+00 -1.20208155 0.53212766 177.75 1.01332685e+00 -3.51010859e+00 3.65344955e+00 -1.28974939 0.53710215 178.00 6.72638804e-01 -3.37486996e+00 3.44124835e+00 -1.37406618 0.41995828 178.25 6.96887545e-01 -3.57168719e+00 3.63903856e+00 -1.37810286 0.42676049 178.50 1.32823147e+00 -2.60433415e+00 2.92348341e+00 -1.09917434 0.29541901 178.75 8.11069376e-01 -3.20353082e+00 3.30460940e+00 -1.32282713 0.31940567 179.00 -8.29614647e-01 -2.29874120e+00 2.44386406e+00 -1.91714802 0.24626160 179.25 -1.56153093e+00 -1.73985703e+00 2.33783689e+00 -2.30223144 0.31050510 179.50 -1.16511270e+00 -3.93260709e-01 1.22969166e+00 -2.81606970 0.11135355 179.75 -6.41602870e-01 9.97237499e-02 6.49306606e-01 2.98739736 0.04587836 180.00 4.98906865e-01 2.78963200e-01 5.71601721e-01 0.50984014 0.04182119 180.25 8.67938915e-01 2.42756238e-01 9.01248329e-01 0.27272378 0.12517456 180.50 1.80792586e+00 1.95784469e-01 1.81849594e+00 0.10787194 0.38465755 180.75 2.00589244e+00 -9.41408535e-02 2.00810034e+00 -0.04689774 0.46585227 181.00 2.13136958e+00 -1.08800477e+00 2.39300870e+00 -0.47199017 0.54027413 181.25 2.36019180e+00 -1.35457039e+00 2.72128026e+00 -0.52102516 0.60893068 181.50 1.91175402e+00 -1.24553220e+00 2.28169978e+00 -0.57743796 0.44336503 181.75 1.86914534e+00 -1.33971060e+00 2.29968015e+00 -0.62187958 0.50163276 182.00 1.82891747e+00 -1.21373358e+00 2.19501442e+00 -0.58590079 0.53031437 182.25 1.86432369e+00 -1.13888129e+00 2.18466322e+00 -0.54838238 0.55591283 182.50 2.22198243e+00 -1.33967921e+00 2.59459945e+00 -0.54256431 0.61800534 182.75 2.34007193e+00 -1.30309318e+00 2.67843022e+00 -0.50809498 0.63202976 183.00 2.02523136e+00 -1.31473526e+00 2.41455811e+00 -0.57579702 0.54299196 183.25 2.04157236e+00 -1.33102301e+00 2.43713766e+00 -0.57775167 0.52406700 183.50 1.72654843e+00 -8.91296208e-01 1.94303330e+00 -0.47654720 0.43396428 183.75 2.01220866e+00 -1.03697942e+00 2.26369389e+00 -0.47584723 0.48668636 184.00 2.18339633e+00 -1.12078187e+00 2.45425580e+00 -0.47424705 0.59051834 184.25 2.14328760e+00 -1.00920749e+00 2.36900433e+00 -0.44007234 0.54791672 184.50 2.03694642e+00 -1.35921459e+00 2.44879869e+00 -0.58842743 0.52735609 184.75 1.91751765e+00 -1.03868897e+00 2.18076792e+00 -0.49643629 0.49578208 185.00 1.93150551e+00 -7.76536115e-01 2.08175932e+00 -0.38226093 0.55935863 185.25 1.95027567e+00 -6.15807284e-01 2.04518796e+00 -0.30584659 0.51701304 185.50 1.82349853e+00 -5.09416468e-01 1.89331773e+00 -0.27241713 0.46847691 185.75 1.72809814e+00 -5.60259916e-01 1.81664921e+00 -0.31351365 0.33781375 186.00 1.76059497e+00 -1.02384661e+00 2.03665326e+00 -0.52673122 0.36304675 186.25 1.69938402e+00 -8.78881835e-01 1.91320133e+00 -0.47729436 0.31305472 186.50 2.00276403e+00 -1.09565453e+00 2.28287595e+00 -0.50059184 0.50927419 186.75 1.64354892e+00 -8.02043249e-01 1.82880465e+00 -0.45399737 0.35666267 187.00 1.70129419e+00 -5.98495961e-01 1.80349642e+00 -0.33826737 0.50842356 187.25 1.61427350e+00 -7.97569042e-01 1.80055417e+00 -0.45889482 0.48907353 187.50 1.48678796e+00 -8.79489570e-01 1.72743750e+00 -0.53417321 0.52621698 187.75 1.19261443e+00 -3.93993061e-01 1.25600944e+00 -0.31907290 0.39222178 188.00 1.13355559e+00 2.52239474e-02 1.13383619e+00 0.02224839 0.49470628 188.25 1.15658397e+00 -8.55452101e-02 1.15974328e+00 -0.07382925 0.44265864 188.50 1.18525941e+00 -5.49303182e-02 1.18653159e+00 -0.04631142 0.50313376 188.75 1.40247981e+00 1.68344602e-01 1.41254718e+00 0.11946198 0.40327904 189.00 1.52713237e+00 2.72773390e-01 1.55130223e+00 0.17675403 0.41431682 189.25 1.34903259e+00 3.23370636e-01 1.38724818e+00 0.23526657 0.31591270 189.50 1.28518953e+00 2.75393736e-01 1.31436442e+00 0.21109034 0.32583603 189.75 1.49657641e+00 2.10937573e-01 1.51136879e+00 0.14002437 0.33970475 190.00 1.45709115e+00 1.48378326e-01 1.46462649e+00 0.10148206 0.40653911 190.25 1.22527550e+00 6.46995502e-02 1.22698252e+00 0.05275509 0.41831522 190.50 1.05078183e+00 1.50997433e-02 1.05089032e+00 0.01436902 0.46929078 190.75 6.66848637e-01 1.71228046e-01 6.88481044e-01 0.25134207 0.25725566 191.00 5.02522054e-01 2.91790527e-01 5.81093905e-01 0.52607167 0.19290649 191.25 1.23050823e-01 2.16199458e-01 2.48764368e-01 1.05336644 0.03496108 191.50 -8.99430322e-02 4.77292434e-02 1.01822540e-01 2.65371831 0.00596607 191.75 1.32295690e-01 -3.58502343e-01 3.82133589e-01 -1.21727584 0.01734146 192.00 1.34487348e+00 6.29659000e-01 1.48497647e+00 0.43787898 0.12962088 192.25 1.51949928e+00 8.04255758e-01 1.71921650e+00 0.48680411 0.26076497 192.50 1.40014528e+00 1.17468694e+00 1.82764773e+00 0.69805858 0.32030538 192.75 1.11263953e+00 9.64168650e-01 1.47227304e+00 0.71402965 0.28665300 193.00 1.20398517e+00 1.19260458e+00 1.69466397e+00 0.78064954 0.40615527 193.25 8.33200465e-01 1.76559245e+00 1.95231650e+00 1.12987230 0.44790221 193.50 8.10479209e-01 2.06982496e+00 2.22284770e+00 1.19757915 0.47169268 193.75 5.22842300e-01 1.94691096e+00 2.01589344e+00 1.30843677 0.34897400 194.00 5.08784456e-01 2.13436357e+00 2.19416715e+00 1.33678595 0.31793149 194.25 6.90929279e-01 2.86237110e+00 2.94458004e+00 1.33394357 0.39940352 194.50 9.60951283e-01 2.01506248e+00 2.23246594e+00 1.12581185 0.25588047 194.75 1.33901580e+00 8.28946491e-01 1.57483827e+00 0.55432475 0.15020483 195.00 1.35349150e+00 8.36907875e-01 1.59133718e+00 0.55379038 0.16769272 195.25 1.74560438e+00 1.17718822e+00 2.10544692e+00 0.59331870 0.33026751 195.50 1.77308109e+00 9.21222212e-01 1.99811584e+00 0.47917297 0.28249219 195.75 1.87324636e+00 2.41789997e-01 1.88878647e+00 0.12836565 0.28868745 196.00 1.71884142e+00 3.71482675e-01 1.75852643e+00 0.21285013 0.23233106 196.25 1.95841451e+00 6.02924333e-02 1.95934239e+00 0.03077663 0.26413629 196.50 1.17620711e+00 -4.20374191e-01 1.24907071e+00 -0.34325029 0.13492725 196.75 4.68011581e-01 -3.49743357e-01 5.84256156e-01 -0.64176854 0.05677141 197.00 1.44898777e-01 1.50256354e-01 2.08740575e-01 0.80354790 0.00666120 197.25 -2.40859604e-01 8.89345974e-01 9.21384616e-01 1.83527954 0.15020457 197.50 -1.56019918e-01 1.54630754e+00 1.55415869e+00 1.67135438 0.23782542 197.75 1.93740097e-01 2.59692364e+00 2.60414047e+00 1.49633058 0.43165739 198.00 4.18725467e-01 2.67073141e+00 2.70335667e+00 1.41527926 0.36488017 198.25 8.64695643e-01 2.34771715e+00 2.50189416e+00 1.21790075 0.34816642 198.50 1.49550956e+00 1.93021982e+00 2.44178160e+00 0.91161924 0.25480353 198.75 1.56062065e+00 1.46647323e+00 2.14151361e+00 0.75430660 0.21265989 199.00 1.37300225e+00 1.21047471e+00 1.83040547e+00 0.72257057 0.18806556 199.25 7.84969121e-01 1.46292340e+00 1.66021728e+00 1.07831808 0.16771566 199.50 8.64690342e-01 8.47168228e-01 1.21053021e+00 0.77516280 0.07020812 199.75 8.28503479e-01 7.23884976e-01 1.10019429e+00 0.71810795 0.05478480 200.00 -1.03950861e+00 7.70459313e-01 1.29390328e+00 2.50376257 0.08146529 200.25 -9.43635014e-01 1.01027281e+00 1.38242475e+00 2.32210282 0.08325703 200.50 2.68186402e-01 9.67042022e-01 1.00354084e+00 1.30026846 0.04357446 200.75 7.04026302e-01 1.02755194e+00 1.24559866e+00 0.97010709 0.07371125 201.00 1.03605345e+00 4.99366674e-01 1.15011905e+00 0.44913551 0.06351615 201.25 1.65779676e+00 3.93731796e-01 1.70391162e+00 0.23318269 0.10421729 201.50 1.19825644e+00 4.41813434e-01 1.27711300e+00 0.35324794 0.08192780 201.75 1.48524085e+00 2.25835175e-01 1.50231219e+00 0.15089706 0.11348789 202.00 1.04395441e+00 1.08410528e-01 1.04956832e+00 0.10347514 0.03835519 202.25 5.53195639e-01 -2.46374024e-02 5.53743999e-01 -0.04450710 0.00885286 202.50 8.77985543e-01 -1.82410874e-01 8.96734264e-01 -0.20484650 0.02748668 202.75 7.88804728e-01 -7.49101679e-01 1.08782638e+00 -0.75958760 0.04411393 203.00 7.31768641e-01 -1.29301873e+00 1.48572635e+00 -1.05579893 0.11651613 203.25 1.08612034e+00 -1.25994122e+00 1.66346304e+00 -0.85935354 0.12483931 203.50 7.98847604e-01 -1.48359958e+00 1.68500007e+00 -1.07686212 0.17551216 203.75 4.50985584e-01 -1.73261680e+00 1.79034884e+00 -1.31615516 0.17060112 204.00 4.51230583e-01 -1.14222187e+00 1.22812045e+00 -1.19456762 0.16652243 204.25 4.01740486e-01 -1.43097287e+00 1.48629700e+00 -1.29709562 0.24365665 204.50 8.12003969e-01 -1.97149681e+00 2.13217028e+00 -1.18009770 0.45569835 204.75 5.74210833e-01 -2.08718851e+00 2.16473415e+00 -1.30232589 0.46122412 205.00 -1.64835422e-01 -2.13731297e+00 2.14365982e+00 -1.64776670 0.46968776 205.25 -5.92644522e-01 -1.95177492e+00 2.03976785e+00 -1.86559277 0.39515419 205.50 -9.58018908e-01 -1.60328387e+00 1.86770431e+00 -2.10940167 0.39510147 205.75 -1.21477166e+00 -1.10986602e+00 1.64543999e+00 -2.40129163 0.32655712 206.00 -1.23190314e+00 -6.89089556e-01 1.41153455e+00 -2.63158412 0.33866161 206.25 -1.50434058e+00 -5.91393818e-01 1.61641184e+00 -2.76702706 0.42168991 206.50 -1.84829415e+00 -3.80351400e-01 1.88702370e+00 -2.93864073 0.52215265 206.75 -1.60192131e+00 -1.05198027e-01 1.60537177e+00 -3.07601690 0.40004020 207.00 -1.79061744e+00 1.15574043e-01 1.79434339e+00 3.07713782 0.56107457 207.25 -1.92585021e+00 1.83952049e-01 1.93461556e+00 3.04636424 0.53265758 207.50 -1.99012825e+00 1.94851453e-01 1.99964435e+00 3.04399473 0.53404592 207.75 -1.95318504e+00 1.89104867e-01 1.96231813e+00 3.04507477 0.47964061 208.00 -2.10868963e+00 4.05424740e-01 2.14731022e+00 2.95164667 0.49157705 208.25 -1.98569262e+00 3.17483016e-01 2.01091289e+00 2.98304925 0.34718921 208.50 -2.21557425e+00 2.14902637e-01 2.22597224e+00 3.04489878 0.42158403 208.75 -2.35224819e+00 -6.65819969e-02 2.35319032e+00 -3.11329452 0.31988625 209.00 -1.62127259e+00 -3.39479855e-01 1.65643333e+00 -2.93518383 0.14107117 209.25 -1.52551724e+00 -3.85005989e-01 1.57335072e+00 -2.89437775 0.09648671 209.50 -2.03125616e+00 -6.33323277e-01 2.12769828e+00 -2.83935568 0.15300461 209.75 -9.29987025e-01 -6.17897299e-01 1.11654509e+00 -2.55515054 0.04134362 210.00 1.24702332e+00 -4.88561022e-01 1.33931290e+00 -0.37340169 0.04596069 210.25 1.56271743e+00 1.88007841e-01 1.57398625e+00 0.11973282 0.04891547 210.50 1.25451507e+00 -9.05734451e-01 1.54730829e+00 -0.62532566 0.03887089 210.75 1.52246172e+00 -3.23330678e-01 1.55641653e+00 -0.20926445 0.05542599 211.00 1.57385088e+00 1.90994461e-01 1.58539758e+00 0.12076434 0.05412572 211.25 1.91037449e+00 1.05003893e+00 2.17993405e+00 0.50257510 0.08696460 211.50 2.30519421e+00 2.72728544e-01 2.32127147e+00 0.11776302 0.10931218 211.75 1.58701265e+00 -4.15264658e-01 1.64044320e+00 -0.25592640 0.09312537 212.00 1.36761045e+00 9.89573636e-02 1.37118594e+00 0.07223197 0.07625293 212.25 9.53045610e-01 -2.38091934e-01 9.82335841e-01 -0.24481130 0.04625250 212.50 7.42863392e-01 -9.41072069e-02 7.48800497e-01 -0.12601049 0.02829419 212.75 1.06582930e+00 2.41543980e-01 1.09285662e+00 0.22286097 0.05524372 213.00 1.19080274e+00 -1.89356600e-01 1.20576410e+00 -0.15769561 0.07713797 213.25 1.47412806e+00 -4.60720514e-01 1.54444712e+00 -0.30291917 0.10752618 213.50 1.45856305e+00 -2.01783198e-01 1.47245463e+00 -0.13747124 0.09949830 213.75 1.71921709e+00 2.16920429e-01 1.73284791e+00 0.12551073 0.13154107 214.00 1.57407455e+00 1.32029329e-01 1.57960199e+00 0.08368155 0.11258000 214.25 2.14210824e+00 2.11835579e-01 2.15255709e+00 0.09857068 0.18192482 214.50 1.86126419e+00 2.89960102e-01 1.88371474e+00 0.15454440 0.14779327 214.75 1.26469549e+00 7.30468285e-01 1.46049258e+00 0.52377430 0.11789334 215.00 9.05646000e-01 9.92428213e-01 1.34354324e+00 0.83108754 0.09812720 215.25 -2.62806475e-01 1.55405884e+00 1.57612376e+00 1.73832110 0.10949471 215.50 -1.21922755e-01 1.31795410e+00 1.32358157e+00 1.66304288 0.07669901 215.75 -2.10777792e-01 -5.05307327e-01 5.47505956e-01 -1.96598040 0.01291069 216.00 -3.07102539e-01 -7.69576319e-01 8.28588970e-01 -1.95048696 0.02952847 216.25 -2.69470333e-01 -1.61651741e+00 1.63882360e+00 -1.73597556 0.12814843 216.50 -1.90099737e-01 -1.42159648e+00 1.43425049e+00 -1.70373042 0.10243797 216.75 -3.52453770e-01 -1.22633764e+00 1.27598106e+00 -1.85065704 0.09223447 217.00 -3.45642801e-02 -1.14971403e+00 1.15023347e+00 -1.60085065 0.07403380 217.25 1.24032759e-02 -1.29481614e+00 1.29487554e+00 -1.56121744 0.10044291 217.50 5.13732968e-01 -1.55843555e+00 1.64092746e+00 -1.25236750 0.14165655 217.75 4.93904242e-01 -2.29845230e+00 2.35091990e+00 -1.35912954 0.34469160 218.00 5.02277861e-01 -2.08031577e+00 2.14009269e+00 -1.33388730 0.26410835 218.25 4.81448710e-01 -1.90508158e+00 1.96497549e+00 -1.32326104 0.29106541 218.50 7.63363098e-01 -2.03417196e+00 2.17268930e+00 -1.21178923 0.30453893 218.75 1.08437347e+00 -2.04487347e+00 2.31460004e+00 -1.08321232 0.43789024 219.00 1.26114086e+00 -2.11734285e+00 2.46447094e+00 -1.03360046 0.48774817 219.25 1.60008940e+00 -2.35564492e+00 2.84769189e+00 -0.97412760 0.64139708 219.50 1.78351330e+00 -2.52221453e+00 3.08909143e+00 -0.95530649 0.65780069 219.75 1.95843175e+00 -2.63170334e+00 3.28044469e+00 -0.93103759 0.75878760 220.00 1.91289746e+00 -2.72273271e+00 3.32752913e+00 -0.95835078 0.71460645 220.25 1.77195301e+00 -2.85235870e+00 3.35794098e+00 -1.01491712 0.71748424 220.50 1.39108518e+00 -2.71589724e+00 3.05142848e+00 -1.09743566 0.57233279 220.75 7.64598814e-01 -2.75674882e+00 2.86081726e+00 -1.30024176 0.58586194 221.00 4.17130296e-02 -2.64804902e+00 2.64837754e+00 -1.55504527 0.49836664 221.25 1.59287156e-01 -2.46042063e+00 2.46557134e+00 -1.50614674 0.57938586 221.50 9.58202484e-01 -2.01781955e+00 2.23377432e+00 -1.12745386 0.63505895 221.75 1.27483310e+00 -2.17975875e+00 2.52518270e+00 -1.04159061 0.75508235 222.00 6.61381175e-01 -1.99621458e+00 2.10292599e+00 -1.25086096 0.69739315 222.25 7.58039218e-01 -1.91762269e+00 2.06201364e+00 -1.19434689 0.73549571 222.50 1.27273283e+00 -1.98075282e+00 2.35440663e+00 -0.99967617 0.84085438 222.75 1.37840179e+00 -1.91207722e+00 2.35712342e+00 -0.94618585 0.85515397 223.00 1.46359500e+00 -1.88771742e+00 2.38863714e+00 -0.91128308 0.84921124 223.25 1.60708580e+00 -1.89021485e+00 2.48105562e+00 -0.86617845 0.85895406 223.50 1.96587170e+00 -2.01410786e+00 2.81447722e+00 -0.79751727 0.87711832 223.75 1.93996752e+00 -2.12572363e+00 2.87787681e+00 -0.83105511 0.86983515 224.00 1.88033512e+00 -1.87063028e+00 2.65234195e+00 -0.78281088 0.82713878 224.25 2.04305971e+00 -1.79184156e+00 2.71749686e+00 -0.71998325 0.81615347 224.50 2.58565631e+00 -2.08266172e+00 3.32010518e+00 -0.67806581 0.84158933 224.75 2.50401674e+00 -2.53332648e+00 3.56199985e+00 -0.79121659 0.84190275 225.00 1.82580159e+00 -2.66749937e+00 3.23250744e+00 -0.97057494 0.87568581 225.25 1.50106020e+00 -2.50309487e+00 2.91867532e+00 -1.03061090 0.81075296 225.50 1.50519396e+00 -1.96966216e+00 2.47894693e+00 -0.91827599 0.77125235 225.75 1.47274424e+00 -1.65365667e+00 2.21439743e+00 -0.84319974 0.67977192 226.00 1.39914739e+00 -1.67012310e+00 2.17874381e+00 -0.87345653 0.73079344 226.25 1.45353285e+00 -1.45939656e+00 2.05975631e+00 -0.78741116 0.67671258 226.50 1.95747269e+00 -1.15744220e+00 2.27406503e+00 -0.53399357 0.67341994 226.75 2.24100880e+00 -8.74666010e-01 2.40565190e+00 -0.37211655 0.56102596 227.00 2.96859053e+00 -1.38158678e+00 3.27434143e+00 -0.43558782 0.57483903 227.25 1.78972520e+00 -2.06808801e+00 2.73497794e+00 -0.85742892 0.35334117 227.50 1.18017732e+00 -2.98956829e+00 3.21408417e+00 -1.19481090 0.50123005 227.75 1.03157694e+00 -2.97207573e+00 3.14601099e+00 -1.23671653 0.50456742 228.00 1.01957378e+00 -3.31446080e+00 3.46773428e+00 -1.27236914 0.72932630 228.25 9.18309670e-01 -2.62920714e+00 2.78496371e+00 -1.23476979 0.64904057 228.50 8.18893735e-01 -2.11654248e+00 2.26943584e+00 -1.20163239 0.66610682 228.75 7.02465893e-01 -1.75690260e+00 1.89213242e+00 -1.19043478 0.53441011 229.00 1.14890992e+00 -1.21819021e+00 1.67450930e+00 -0.81465781 0.58692897 229.25 1.42260960e+00 -9.97913082e-01 1.73771361e+00 -0.61170956 0.55331470 229.50 1.81595028e+00 -9.95595317e-01 2.07096245e+00 -0.50149889 0.56708313 229.75 1.87214592e+00 -8.56757863e-01 2.05887454e+00 -0.42918430 0.34829820 230.00 1.62003561e+00 -1.31764773e+00 2.08823153e+00 -0.68282528 0.26230192 230.25 1.36358398e+00 -1.58126957e+00 2.08800736e+00 -0.85918465 0.27158321 230.50 1.40275163e+00 -2.27378870e+00 2.67167124e+00 -1.01802658 0.45860791 230.75 1.04162122e+00 -2.13320378e+00 2.37392779e+00 -1.11656085 0.47625123 231.00 9.83090270e-01 -2.10294803e+00 2.32139115e+00 -1.13349988 0.59845064 231.25 1.03148893e+00 -1.73545146e+00 2.01885145e+00 -1.03453165 0.52955978 231.50 1.22568353e+00 -1.96323345e+00 2.31442989e+00 -1.01268702 0.58151289 231.75 1.20933888e+00 -1.65115232e+00 2.04665691e+00 -0.93864093 0.49411838 232.00 1.26986798e+00 -1.55509304e+00 2.00770492e+00 -0.88602318 0.56449986 232.25 1.28174925e+00 -1.19810095e+00 1.75451618e+00 -0.75167976 0.42273218 232.50 1.42453229e+00 -1.21379186e+00 1.87151888e+00 -0.70569077 0.47961412 232.75 1.98168461e+00 -1.28887368e+00 2.36395204e+00 -0.57665140 0.64600565 233.00 2.05346153e+00 -1.29717409e+00 2.42886082e+00 -0.56340364 0.66545830 233.25 1.93941928e+00 -7.40727273e-01 2.07605974e+00 -0.36483459 0.45430368 233.50 2.06290960e+00 -7.77548640e-01 2.20458112e+00 -0.36045152 0.50933729 233.75 2.37627685e+00 -1.00247825e+00 2.57908013e+00 -0.39921593 0.54451541 234.00 2.50750018e+00 -8.55707161e-01 2.64948899e+00 -0.32886667 0.49491537 234.25 2.12835607e+00 -5.82408273e-01 2.20660349e+00 -0.26710354 0.37596109 234.50 2.31378747e+00 -7.88153280e-01 2.44434000e+00 -0.32830616 0.44353411 234.75 2.80144890e+00 -8.18532897e-01 2.91858048e+00 -0.28426896 0.55996210 235.00 2.89520048e+00 -5.44380790e-01 2.94593555e+00 -0.18585865 0.48527739 235.25 2.36477773e+00 -1.86145411e-01 2.37209271e+00 -0.07855384 0.36278973 235.50 2.39372813e+00 7.48860800e-02 2.39489922e+00 0.03127409 0.31754944 235.75 2.73462729e+00 -8.60759405e-01 2.86689609e+00 -0.30494518 0.46844145 236.00 2.53770027e+00 -1.10985654e+00 2.76978415e+00 -0.41228233 0.50143284 236.25 2.49766928e+00 -5.05136748e-01 2.54823762e+00 -0.19955160 0.52556583 236.50 2.31847132e+00 -1.29960733e-01 2.32211090e+00 -0.05599589 0.46381913 236.75 2.35596736e+00 -2.50785999e-01 2.36927749e+00 -0.10604781 0.55297787 237.00 2.00827559e+00 -8.66291668e-02 2.01014315e+00 -0.04310937 0.52980835 237.25 1.48218105e+00 2.71278046e-01 1.50680206e+00 0.18102267 0.64705844 237.50 1.12032470e+00 5.19090141e-01 1.23473965e+00 0.43389112 0.57765931 237.75 7.28098915e-01 7.50141224e-01 1.04538982e+00 0.80030824 0.65344872 238.00 5.48942577e-01 7.66929462e-01 9.43143018e-01 0.94956687 0.62136457 238.25 2.68388372e-01 7.39413399e-01 7.86615848e-01 1.22260982 0.57615950 238.50 1.03311210e-01 6.83898620e-01 6.91657812e-01 1.42086774 0.50812809 238.75 -6.46250207e-02 5.89519176e-01 5.93050800e-01 1.67998361 0.55733167 239.00 -2.22717937e-01 4.81211700e-01 5.30252750e-01 2.00426613 0.45016951 239.25 -3.05217089e-01 3.88220447e-01 4.93834574e-01 2.23706290 0.55137735 239.50 -3.76356428e-01 3.58404720e-01 5.19709635e-01 2.38062166 0.49183657 239.75 -4.28511935e-01 3.64711507e-01 5.62705039e-01 2.43645356 0.54276385 240.00 -4.20656432e-01 2.18227501e-01 4.73893528e-01 2.66303537 0.45571037 240.25 -3.76519688e-01 1.64542902e-01 4.10903203e-01 2.72959349 0.55281787 240.50 -2.98946004e-01 1.07580708e-01 3.17714214e-01 2.79615510 0.28216457 240.75 -2.51942019e-01 -2.71926005e-02 2.53405246e-01 -3.03407688 0.18332702 241.00 4.13933180e-02 -1.25113051e-01 1.31782708e-01 -1.25128485 0.06248775 241.25 1.07496145e-01 -2.45647891e-01 2.68138598e-01 -1.15829981 0.23930592 241.50 1.57812868e-01 -4.82994222e-01 5.08122348e-01 -1.25499270 0.41886533 241.75 2.04322556e-01 -6.65001241e-01 6.95682656e-01 -1.27270023 0.58180023 242.00 1.76414154e-01 -1.09480753e+00 1.10892988e+00 -1.41103251 0.70122050 242.25 -1.88327444e-03 -1.38813479e+00 1.38813607e+00 -1.57215302 0.77755593 242.50 -2.12882731e-01 -1.68912094e+00 1.70248307e+00 -1.69616699 0.81263232 242.75 -4.08525050e-01 -1.93583193e+00 1.97846859e+00 -1.77877800 0.84897938 243.00 -8.55273545e-01 -2.26684773e+00 2.42282716e+00 -1.93157878 0.80694846 243.25 -1.17127989e+00 -2.29168979e+00 2.57366250e+00 -2.04328350 0.77236689 243.50 -1.48868054e+00 -1.39353773e+00 2.03914618e+00 -2.38919278 0.63779890 243.75 -1.53482442e+00 -9.62083139e-01 1.81143312e+00 -2.58167419 0.58135999 244.00 -1.14918380e+00 -6.31953806e-01 1.31148352e+00 -2.63881444 0.33636388 244.25 -1.19508816e+00 -2.02041352e-01 1.21204637e+00 -2.97411644 0.32022931 244.50 -1.08839572e+00 1.31309173e-02 1.08847492e+00 3.12952877 0.22148653 244.75 -6.67775322e-01 -2.26044383e-02 6.68157797e-01 -3.10775521 0.09718104 245.00 -1.67028111e-01 -6.37172061e-01 6.58700710e-01 -1.82716758 0.13925153 245.25 -3.20287763e-01 -8.33087443e-01 8.92535119e-01 -1.93783371 0.26841154 245.50 -7.07946570e-01 -1.08004204e+00 1.29138653e+00 -2.15101467 0.52259466 245.75 -6.65506529e-01 -1.02933533e+00 1.22573658e+00 -2.14473541 0.49617903 246.00 -6.50449505e-01 -6.04651455e-01 8.88081044e-01 -2.39266784 0.38323018 246.25 -8.33570274e-01 -6.44798293e-01 1.05385210e+00 -2.48319662 0.41162623 246.50 -6.10014783e-01 -9.83792686e-01 1.15756904e+00 -2.12583854 0.44917861 246.75 -6.70045130e-01 -9.68882926e-01 1.17800450e+00 -2.17583848 0.43798232 247.00 -7.72964887e-01 -4.98062540e-01 9.19533039e-01 -2.56919718 0.38184937 247.25 -5.83041959e-01 -5.85809612e-01 8.26505189e-01 -2.35382666 0.26374583 247.50 -4.44273528e-01 -9.46513719e-01 1.04559418e+00 -2.00964833 0.37693384 247.75 -4.36691546e-01 -9.45325893e-01 1.04131674e+00 -2.00354179 0.33959770 248.00 -7.27225310e-01 -6.60684506e-01 9.82527693e-01 -2.40410098 0.34198982 248.25 -7.05294867e-01 -5.68087965e-01 9.05629497e-01 -2.46353030 0.23011503 248.50 -8.16983815e-01 -7.42067037e-01 1.10368747e+00 -2.40421037 0.26206994 248.75 -7.11321944e-01 -4.45660694e-01 8.39400001e-01 -2.58189775 0.15910213 249.00 -5.02759670e-01 -5.96741358e-01 7.80299644e-01 -2.27092508 0.20043172 249.25 -5.22130193e-01 -5.18834306e-01 7.36076745e-01 -2.35936066 0.14954457 249.50 -5.75059556e-01 -6.80648386e-01 8.91053151e-01 -2.27230474 0.25195227 249.75 -3.58734626e-01 -7.75604091e-01 8.54547972e-01 -2.00401533 0.13953723 250.00 -1.63590822e-01 -4.81810001e-01 5.08824954e-01 -1.89811696 0.02538123 250.25 -4.29557983e-01 -4.78363641e-01 6.42924438e-01 -2.30249081 0.05535311 250.50 -4.55461336e-01 -6.54118466e-01 7.97067122e-01 -2.17903336 0.19530609 250.75 -4.55026012e-01 -6.08993916e-01 7.60211984e-01 -2.21248802 0.19199689 251.00 -4.93150831e-01 -4.37936253e-01 6.59534611e-01 -2.41542632 0.13219172 251.25 -4.92332561e-01 -3.34415190e-01 5.95167935e-01 -2.54493140 0.11575783 251.50 -5.20306547e-01 -2.42383420e-01 5.73993576e-01 -2.70563851 0.17399380 251.75 -4.61382499e-02 -5.38543887e-01 5.40516657e-01 -1.65625986 0.15301289 252.00 2.36844435e-01 -7.22491900e-01 7.60322189e-01 -1.25401953 0.32527912 252.25 3.15924414e-01 -1.13031664e+00 1.17363706e+00 -1.29825059 0.43416331 252.50 1.28406740e-01 -1.32959519e+00 1.33578129e+00 -1.47451909 0.51210905 252.75 1.97544410e-01 -1.49330781e+00 1.50631736e+00 -1.43927352 0.51114210 253.00 1.39209044e-01 -1.51504064e+00 1.52142279e+00 -1.47916892 0.53294865 253.25 5.67085353e-02 -1.49530050e+00 1.49637543e+00 -1.53288999 0.52882207 253.50 -2.12354862e-01 -1.59655649e+00 1.61061703e+00 -1.70302824 0.54553681 253.75 -1.99188137e-01 -1.79111557e+00 1.80215729e+00 -1.68155022 0.54274976 254.00 -3.14568427e-01 -1.78156837e+00 1.80912663e+00 -1.74556325 0.56318658 254.25 -6.35797677e-01 -2.00556385e+00 2.10393086e+00 -1.87779095 0.65853249 254.50 -7.71446799e-01 -2.06077955e+00 2.20044143e+00 -1.92899445 0.68128974 254.75 -6.60304271e-01 -2.25689101e+00 2.35150139e+00 -1.85542506 0.66143592 255.00 -6.85890044e-01 -2.35620463e+00 2.45400600e+00 -1.85406768 0.71603732 255.25 -8.22454909e-01 -2.71259582e+00 2.83453844e+00 -1.86518491 0.70646183 255.50 -1.03094391e+00 -2.75974703e+00 2.94602258e+00 -1.92830801 0.70493116 255.75 -1.67122462e+00 -2.39411739e+00 2.91972427e+00 -2.18021545 0.72082531 256.00 -2.07119818e+00 -2.40737679e+00 3.17574005e+00 -2.28127125 0.71756282 256.25 -2.65629472e+00 -2.26338168e+00 3.48981350e+00 -2.43589096 0.63683255 256.50 -2.90930584e+00 -2.30462202e+00 3.71151494e+00 -2.47165341 0.58370108 256.75 -3.64649406e+00 -4.88147162e-01 3.67902251e+00 -3.00851629 0.54062539 257.00 -2.73322764e+00 2.48502473e-01 2.74450120e+00 3.05092288 0.42243148 257.25 -2.18171379e+00 3.58080451e-01 2.21090404e+00 2.97891498 0.54083169 257.50 -1.95851469e+00 5.27590289e-01 2.02833215e+00 2.87845612 0.55584971 257.75 -1.70596243e+00 3.27460296e-01 1.73710623e+00 2.95194887 0.59172542 258.00 -1.65151794e+00 3.48191470e-01 1.68782369e+00 2.93380452 0.61323761 258.25 -1.35189182e+00 3.33741950e-01 1.39247808e+00 2.89956175 0.66296484 258.50 -1.15192037e+00 2.47452445e-01 1.17819915e+00 2.92999111 0.52090109 258.75 -1.07262888e+00 3.48170735e-03 1.07263453e+00 3.13834671 0.61477798 259.00 -1.11791160e+00 4.54777186e-02 1.11883625e+00 3.10093411 0.62262758 259.25 -1.17093603e+00 2.05074223e-02 1.17111559e+00 3.12408074 0.62653790 259.50 -1.11613309e+00 -2.21410451e-01 1.13788210e+00 -2.94576219 0.53549476 259.75 -1.14218426e+00 -5.39435312e-01 1.26316085e+00 -2.70036269 0.58439306 260.00 -1.27816794e+00 -5.70544808e-01 1.39972664e+00 -2.72175567 0.61801083 260.25 -1.30664679e+00 -5.75501376e-01 1.42777018e+00 -2.72671601 0.64451429 260.50 -1.32296860e+00 -4.04428888e-01 1.38340473e+00 -2.84491655 0.51928454 260.75 -1.54860642e+00 -7.63244762e-02 1.55048614e+00 -3.09234659 0.58473094 261.00 -1.47224002e+00 1.24384857e-02 1.47229257e+00 3.13314417 0.47989732 261.25 -1.64320028e+00 4.27122822e-01 1.69780478e+00 2.88728687 0.52664572 261.50 -1.58889354e+00 1.05499814e+00 1.90725031e+00 2.55545035 0.56014005 261.75 -1.11996371e+00 1.42929068e+00 1.81581678e+00 2.23544463 0.49719731 262.00 -2.89383711e-01 7.27232509e-01 7.82694100e-01 1.94951229 0.16153721 262.25 -2.69268778e-01 3.39107796e-01 4.33012439e-01 2.24189910 0.09735160 262.50 -1.82649896e-01 1.27152940e-01 2.22550791e-01 2.53345078 0.04958197 262.75 -1.41466752e-01 1.51168590e-01 2.07038124e-01 2.32305329 0.05997639 263.00 -2.98119556e-01 5.23280447e-02 3.02677211e-01 2.96783565 0.11125233 263.25 -3.01747247e-01 -1.25373977e-01 3.26756844e-01 -2.74780169 0.14703080 263.50 -3.29462992e-01 -1.62053418e-01 3.67160964e-01 -2.68446906 0.16830241 263.75 -3.51592434e-01 -2.37411050e-01 4.24241967e-01 -2.54767466 0.26375748 264.00 -3.18129300e-01 -3.61789327e-01 4.81765263e-01 -2.29206892 0.37404636 264.25 -3.48570420e-01 -4.05060080e-01 5.34392184e-01 -2.28137770 0.43414617 264.50 -5.84664433e-01 -5.16660561e-01 7.80237550e-01 -2.41786352 0.49334665 264.75 -5.47827273e-01 -5.74840277e-01 7.94075605e-01 -2.33213769 0.54864917 265.00 -4.59556113e-01 -4.84440114e-01 6.67738007e-01 -2.32984032 0.50400896 265.25 -4.72753758e-01 -5.03714359e-01 6.90814209e-01 -2.32449839 0.49424260 265.50 -6.67641767e-01 -5.37163601e-01 8.56907384e-01 -2.46407218 0.57911943 265.75 -6.35006325e-01 -5.12258128e-01 8.15868508e-01 -2.46278108 0.55534684 266.00 -6.75262873e-01 -4.66264011e-01 8.20598608e-01 -2.53727604 0.60500093 266.25 -6.77307385e-01 -4.77688036e-01 8.28813099e-01 -2.52733512 0.63607450 266.50 -7.21758868e-01 -5.65532608e-01 9.16931292e-01 -2.47696433 0.63217554 266.75 -6.97381842e-01 -5.73066383e-01 9.02633100e-01 -2.45373562 0.57989198 267.00 -5.37979426e-01 -6.17827894e-01 8.19227178e-01 -2.28721950 0.57911602 267.25 -5.30417567e-01 -6.08720242e-01 8.07392797e-01 -2.28756390 0.54129160 267.50 -3.50253908e-01 -6.86447284e-01 7.70641080e-01 -2.04260355 0.51841323 267.75 -3.16742272e-01 -6.91246193e-01 7.60359761e-01 -2.00046428 0.34971538 268.00 -2.40594506e-01 -9.43160058e-01 9.73363555e-01 -1.82056360 0.43206337 268.25 -6.31239636e-01 -1.16629390e+00 1.32616174e+00 -2.06688564 0.56174604 268.50 -1.10229328e+00 -1.67859432e+00 2.00816567e+00 -2.15185067 0.76842938 268.75 -1.31183560e+00 -1.54185959e+00 2.02441192e+00 -2.27576272 0.73794269 269.00 -1.51956097e+00 -1.18432360e+00 1.92657415e+00 -2.47954861 0.80325677 269.25 -1.60645866e+00 -9.33644849e-01 1.85806408e+00 -2.61512485 0.77829582 269.50 -1.64299480e+00 -8.53232499e-01 1.85133401e+00 -2.66261240 0.83200353 269.75 -1.51011842e+00 -8.75918975e-01 1.74576393e+00 -2.61598394 0.75061306 270.00 -1.35148562e+00 -1.01688545e+00 1.69132179e+00 -2.49654424 0.75396924 270.25 -1.54490881e+00 -1.18078255e+00 1.94447696e+00 -2.48899862 0.71835907 270.50 -1.82996760e+00 -1.35056074e+00 2.27437810e+00 -2.50580009 0.78137351 270.75 -2.07794395e+00 -1.47703638e+00 2.54940925e+00 -2.52364427 0.77660742 271.00 -2.32116959e+00 -1.67423709e+00 2.86197451e+00 -2.51672035 0.82289493 271.25 -3.05602744e+00 -1.10424361e+00 3.24940881e+00 -2.79485750 0.71564730 271.50 -4.23065871e+00 -7.24386609e-01 4.29222658e+00 -2.97201397 0.83665055 271.75 -5.13266246e+00 -2.07586338e-01 5.13685857e+00 -3.10117050 0.84246035 272.00 -5.70250738e+00 3.35441375e-01 5.71236477e+00 3.08283687 0.89252955 272.25 -5.30800093e+00 2.44435013e+00 5.84377630e+00 2.71003887 0.81770957 272.50 -4.86020201e+00 4.21155286e+00 6.43107620e+00 2.42757507 0.84477340 272.75 -3.28988765e+00 5.67391088e+00 6.55870608e+00 2.09625078 0.83720445 273.00 -1.80385700e+00 6.04023852e+00 6.30383862e+00 1.86100497 0.83052648 273.25 6.81018655e-01 5.29256370e+00 5.33619874e+00 1.44282489 0.81157389 273.50 1.38182968e+00 4.96776461e+00 5.15636873e+00 1.29949536 0.88317017 273.75 1.93377805e+00 3.46752519e+00 3.97029325e+00 1.06207400 0.85157581 274.00 2.16252472e+00 2.98779072e+00 3.68827962e+00 0.94428354 0.89014202 274.25 2.02698914e+00 2.17219105e+00 2.97104341e+00 0.81996302 0.85580426 274.50 2.07527978e+00 1.83424249e+00 2.76969884e+00 0.72382221 0.87472815 274.75 2.14522294e+00 1.32838168e+00 2.52320814e+00 0.55443775 0.85510158 275.00 1.97067746e+00 1.02717361e+00 2.22230854e+00 0.48048596 0.83437763 275.25 1.81036888e+00 7.16835528e-01 1.94712318e+00 0.37701967 0.77944718 275.50 1.76372630e+00 5.81123377e-01 1.85699619e+00 0.31828410 0.77127323 275.75 1.62164792e+00 2.64032378e-01 1.64300184e+00 0.16140105 0.64499699 276.00 1.62687697e+00 1.06543295e-01 1.63036197e+00 0.06539608 0.63429440 276.25 1.51144157e+00 -7.65851078e-02 1.51338062e+00 -0.05062694 0.68906030 276.50 1.42105023e+00 -1.52636117e-01 1.42922410e+00 -0.10700055 0.62398693 276.75 1.21563612e+00 -4.01937515e-01 1.28036125e+00 -0.31932429 0.54295381 277.00 1.10649021e+00 -5.24222022e-01 1.22438936e+00 -0.44244440 0.50592506 277.25 9.80969169e-01 -5.57647566e-01 1.12839325e+00 -0.51690990 0.47086889 277.50 1.01503550e+00 -7.51390901e-01 1.26288771e+00 -0.63723877 0.56899852 277.75 7.95393237e-01 -8.85150900e-01 1.19001786e+00 -0.83875735 0.57844482 278.00 5.68674775e-01 -8.66895023e-01 1.03677287e+00 -0.99022148 0.44504752 278.25 3.78374416e-01 -1.04764820e+00 1.11388238e+00 -1.22420932 0.57590147 278.50 1.51584151e-01 -1.09198506e+00 1.10245595e+00 -1.43286257 0.58041081 278.75 -1.55416019e-01 -1.35305737e+00 1.36195388e+00 -1.68515799 0.70702641 279.00 -4.69028011e-01 -1.21642598e+00 1.30371754e+00 -1.93880911 0.59203434 279.25 -7.71106375e-01 -7.65908738e-01 1.08684002e+00 -2.35957612 0.72850059 279.50 -6.65819001e-01 -5.68073926e-01 8.75227358e-01 -2.43524623 0.58711398 279.75 -5.22686163e-01 -2.98882048e-01 6.02105725e-01 -2.62215202 0.52399898 280.00 -4.79584256e-01 -2.72953159e-01 5.51819251e-01 -2.62416941 0.46294304 280.25 -4.27937723e-01 -2.14617024e-01 4.78739138e-01 -2.67673408 0.59108435 280.50 -4.00937256e-01 -2.58238061e-01 4.76904161e-01 -2.56938617 0.54221114 280.75 -3.41371029e-01 -2.62500670e-01 4.30628356e-01 -2.48606715 0.52991852 281.00 -3.10653807e-01 -2.82014712e-01 4.19568929e-01 -2.40447921 0.46938605 281.25 -3.15358430e-01 -2.41800347e-01 3.97389415e-01 -2.48745890 0.47839374 281.50 -3.54778830e-01 -2.16038251e-01 4.15380000e-01 -2.59462713 0.50551603 281.75 -3.71785921e-01 -2.43017752e-01 4.44164833e-01 -2.56265602 0.63254198 282.00 -3.19995885e-01 -2.31162205e-01 3.94757307e-01 -2.51599658 0.48555462 282.25 -2.47914236e-01 -2.37938155e-01 3.43621935e-01 -2.37672476 0.51665571 282.50 -2.31109395e-01 -2.46475512e-01 3.37878278e-01 -2.32403096 0.41824966 282.75 -2.27245255e-01 -2.47077262e-01 3.35689707e-01 -2.31440760 0.47297773 283.00 -2.86197921e-01 -2.72460295e-01 3.95150430e-01 -2.38077993 0.51063791 283.25 -2.89707801e-01 -3.18684801e-01 4.30686211e-01 -2.30860167 0.63289619 283.50 -2.81987434e-01 -3.52872872e-01 4.51703639e-01 -2.24499987 0.63082994 283.75 -3.39302613e-01 -3.74819293e-01 5.05584578e-01 -2.30650068 0.70980186 284.00 -4.45991454e-01 -3.64099724e-01 5.75740381e-01 -2.45694176 0.69412178 284.25 -4.88503762e-01 -3.60727568e-01 6.07256374e-01 -2.50553526 0.72501001 284.50 -4.80742161e-01 -3.31380412e-01 5.83888691e-01 -2.53807723 0.71079462 284.75 -5.30194918e-01 -3.01080201e-01 6.09717917e-01 -2.62513553 0.73699829 285.00 -5.59732488e-01 -1.37618581e-01 5.76402057e-01 -2.90050961 0.74288754 285.25 -5.35700369e-01 -8.28550290e-02 5.42069959e-01 -2.98814181 0.75781844 285.50 -5.51175332e-01 -4.35905021e-02 5.52896354e-01 -3.06267047 0.79952714 285.75 -4.97176361e-01 -4.95542499e-02 4.99639828e-01 -3.04224939 0.78828073 286.00 -4.71909501e-01 -8.72024481e-03 4.71990063e-01 -3.12311612 0.80195218 286.25 -4.51171660e-01 3.15741059e-02 4.52275128e-01 3.07172410 0.76471085 286.50 -4.43396402e-01 2.50965249e-02 4.44106073e-01 3.08505233 0.79345401 286.75 -4.19922420e-01 2.85516315e-02 4.20891951e-01 3.07370451 0.76451623 287.00 -3.44200934e-01 7.53147733e-02 3.52344431e-01 2.92617723 0.73918438 287.25 -3.30986552e-01 6.06617156e-02 3.36499541e-01 2.96032886 0.72450583 287.50 -3.04845006e-01 3.09102544e-02 3.06408097e-01 3.04054140 0.67201758 287.75 -3.18757587e-01 3.53263018e-02 3.20709131e-01 3.03121809 0.66625763 288.00 -2.97284546e-01 -1.50059463e-03 2.97288334e-01 -3.13654503 0.62703730 288.25 -2.80904773e-01 -9.74961887e-03 2.81073917e-01 -3.10689867 0.60600850 288.50 -2.84760128e-01 -1.27754841e-02 2.85046563e-01 -3.09675870 0.69301965 288.75 -2.75339479e-01 -3.00523867e-02 2.76974682e-01 -3.03287633 0.64541484 289.00 -2.69609998e-01 -8.07049342e-02 2.81429987e-01 -2.85074189 0.61757764 289.25 -2.56428810e-01 -7.90513953e-02 2.68337209e-01 -2.84255865 0.51368597 289.50 -2.55555178e-01 -7.78554010e-02 2.67151479e-01 -2.84587343 0.67099711 289.75 -2.46139761e-01 -6.33616772e-02 2.54164285e-01 -2.88964130 0.63274921 290.00 -2.36944456e-01 -5.14848451e-02 2.42473431e-01 -2.92763199 0.62487679 290.25 -2.41685283e-01 -6.78051946e-02 2.51016574e-01 -2.86807252 0.55510675 290.50 -2.52869984e-01 -9.96600958e-02 2.71800227e-01 -2.76616900 0.60379802 290.75 -2.51324135e-01 -1.05164096e-01 2.72439549e-01 -2.74529140 0.55900512 291.00 -2.47813606e-01 -1.04594532e-01 2.68982526e-01 -2.74220690 0.61043192 291.25 -2.82113823e-01 -1.22224685e-01 3.07452570e-01 -2.73275836 0.57694320 291.50 -3.30539098e-01 -1.40671402e-01 3.59227697e-01 -2.73922938 0.69233802 291.75 -3.46623921e-01 -1.47869943e-01 3.76847002e-01 -2.73836714 0.60978079 292.00 -3.54544194e-01 -1.51776599e-01 3.85665297e-01 -2.73710820 0.70154804 292.25 -3.48660108e-01 -1.10595931e-01 3.65780441e-01 -2.83442922 0.66225503 292.50 -3.77104376e-01 -8.39456525e-02 3.86334807e-01 -2.92255813 0.73661385 292.75 -3.94629666e-01 -1.16825459e-01 4.11558940e-01 -2.85377448 0.72189979 293.00 -4.26690047e-01 -1.02403936e-01 4.38806292e-01 -2.90605138 0.72217212 293.25 -4.53217062e-01 -1.68706199e-02 4.53530951e-01 -3.10438568 0.67322999 293.50 -4.19425665e-01 1.29631535e-02 4.19625943e-01 3.11069557 0.70688513 293.75 -3.97426843e-01 4.89558730e-02 4.00430735e-01 3.01902799 0.57494627 294.00 -3.77781377e-01 6.73492056e-02 3.83737781e-01 2.96517049 0.56616516 294.25 -3.48840633e-01 1.49461246e-01 3.79510805e-01 2.73680230 0.49853104 294.50 -3.23148826e-01 2.10473767e-01 3.85647988e-01 2.56428902 0.51994158 294.75 -3.16185922e-01 2.29363527e-01 3.90616391e-01 2.51401764 0.49063714 295.00 -2.93447494e-01 2.42331093e-01 3.80572976e-01 2.45131242 0.47275299 295.25 -1.42606489e-01 2.30556379e-01 2.71095656e-01 2.12473094 0.30988320 295.50 -7.70020335e-02 2.22559356e-01 2.35503674e-01 1.90388918 0.29044257 295.75 -7.13658988e-02 2.28727896e-01 2.39602884e-01 1.87323675 0.34435479 296.00 -8.44707366e-02 1.74614461e-01 1.93972976e-01 2.02136423 0.23899005 296.25 -1.11825151e-01 6.50434168e-02 1.29365801e-01 2.61477296 0.13060834 296.50 -8.14632301e-02 7.51515809e-02 1.10833289e-01 2.39647316 0.11451926 296.75 -8.72564144e-02 1.21589682e-01 1.49658721e-01 2.19325683 0.17500921 297.00 -7.74107386e-02 1.37010001e-01 1.57366333e-01 2.08508336 0.19036856 297.25 1.90516946e-02 6.48676555e-02 6.76075425e-02 1.28512841 0.05134166 297.50 2.86644677e-02 4.67127875e-02 5.48063520e-02 1.02041345 0.03406967 297.75 -7.05449911e-02 6.50913329e-02 9.59868605e-02 2.39638079 0.09665300 298.00 -7.84999193e-02 2.78097552e-02 8.32803687e-02 2.80112356 0.07366954 298.25 -1.23517193e-01 -8.44364144e-03 1.23805460e-01 -3.07333879 0.12691443 298.50 -1.30674760e-01 1.81429431e-04 1.30674886e-01 3.14020425 0.10342060 298.75 -1.65974326e-01 2.91269239e-02 1.68510696e-01 2.96787106 0.20274104 299.00 -1.47759728e-01 9.65881302e-03 1.48075082e-01 3.07631715 0.12574029 299.25 -1.00616071e-01 1.22314161e-01 1.58380389e-01 2.25916881 0.11996997 299.50 -2.04736417e-02 1.70776963e-01 1.71999829e-01 1.69011215 0.08072956 299.75 5.89327976e-02 1.59037971e-01 1.69605869e-01 1.21592566 0.10225388 300.00 8.57384381e-02 1.28617167e-01 1.54575080e-01 0.98282785 0.09926876 300.25 8.56665886e-02 4.37890351e-02 9.62093759e-02 0.47253294 0.05029974 300.50 2.08985936e-02 3.71773740e-02 4.26486618e-02 1.05868642 0.00991276 300.75 -5.32041851e-02 -2.15143795e-03 5.32476666e-02 -3.10117729 0.01909800 301.00 9.98247120e-03 2.87225327e-02 3.04077888e-02 1.23630720 0.00344026 301.25 5.24100961e-02 8.20600300e-02 9.73687152e-02 1.00242017 0.02992186 301.50 1.16368825e-02 8.75665939e-02 8.83364330e-02 1.43867864 0.02763610 301.75 3.49009664e-02 2.45211593e-02 4.26540116e-02 0.61246382 0.00883303 302.00 3.42623602e-02 4.83459883e-02 5.92557500e-02 0.95426135 0.01367861 302.25 1.15369507e-01 1.10654513e-01 1.59857888e-01 0.76454060 0.11280901 302.50 5.48961934e-02 1.00266684e-01 1.14310979e-01 1.06987311 0.04674132 302.75 7.15059396e-03 3.54203266e-02 3.61348936e-02 1.37159540 0.00394462 303.00 1.70960154e-01 -5.29352152e-02 1.78967906e-01 -0.30027247 0.06874224 303.25 1.76982108e-01 -1.49074835e-01 2.31400028e-01 -0.70001607 0.17118235 303.50 1.09821733e-01 -1.00481995e-01 1.48853769e-01 -0.74101662 0.07194159 303.75 6.57337984e-02 -8.06182165e-02 1.04020330e-01 -0.88675253 0.04097103 304.00 9.34579954e-02 -9.57788424e-02 1.33820714e-01 -0.79766179 0.05191312 304.25 1.23378151e-01 -1.21113165e-01 1.72888886e-01 -0.77613436 0.08979358 304.50 5.40404121e-02 -3.54317018e-02 6.46202108e-02 -0.58033822 0.01111481 304.75 1.09975688e-02 5.84107345e-03 1.24524960e-02 0.48823573 0.00059262 305.00 8.40870059e-02 2.64126481e-02 8.81376908e-02 0.30435181 0.01951234 305.25 7.74002421e-02 -1.66346287e-02 7.91675966e-02 -0.21169684 0.01607831 305.50 2.53498364e-01 1.10668761e-01 2.76602595e-01 0.41162621 0.09976081 305.75 4.06525126e-01 3.57774249e-03 4.06540870e-01 0.00880056 0.18067916 306.00 3.15125317e-01 5.19715604e-02 3.19382230e-01 0.16345211 0.09918478 306.25 3.76315466e-01 -1.69609100e-02 3.76697495e-01 -0.04504051 0.12219964 306.50 1.03387457e-01 -4.27118410e-01 4.39453186e-01 -1.33330628 0.14328703 306.75 -5.15804478e-02 -5.41073666e-01 5.43526682e-01 -1.66583892 0.18897400 307.00 -4.01530009e-02 -5.11033102e-01 5.12608130e-01 -1.64920744 0.19373918 307.25 -6.44016604e-02 -5.64135507e-01 5.67799652e-01 -1.68446415 0.27678693 307.50 -1.53491024e-01 -4.42054417e-01 4.67944016e-01 -1.90499418 0.28612763 307.75 -2.09714188e-01 -4.37920246e-01 4.85545242e-01 -2.01741109 0.32697284 308.00 -1.29264134e-01 -2.73497516e-01 3.02506377e-01 -2.01231218 0.17449660 308.25 -1.33687396e-01 -2.73694403e-01 3.04599649e-01 -2.02516534 0.17099901 308.50 -1.96301407e-01 -7.78993546e-02 2.11193162e-01 -2.76381732 0.09162484 308.75 -1.88151165e-01 -5.27311534e-02 1.95400704e-01 -2.86834332 0.08064243 309.00 -1.78418328e-01 -3.22615135e-02 1.81311624e-01 -2.96270604 0.08256014 309.25 -1.61092331e-01 -1.83190444e-02 1.62130585e-01 -3.02836140 0.05801238 309.50 -1.56575342e-01 3.75220458e-03 1.56620294e-01 3.11763303 0.04340765 309.75 -1.15379514e-01 -1.62694660e-02 1.16520933e-01 -3.00150796 0.01866281 310.00 8.42731652e-02 3.66063703e-03 8.43526326e-02 0.04341047 0.01677423 310.25 1.34681889e-01 8.23125033e-02 1.57843465e-01 0.54858673 0.05237838 310.50 2.87375467e-01 2.10051999e-01 3.55958567e-01 0.63118565 0.30290302 310.75 3.21348817e-01 2.30804874e-01 3.95646246e-01 0.62286153 0.34935823 311.00 4.54967242e-01 2.69146222e-01 5.28616004e-01 0.53419995 0.49257311 311.25 6.30012356e-01 3.10814299e-01 7.02510567e-01 0.45831054 0.55075354 311.50 8.77262879e-01 2.80265423e-01 9.20944551e-01 0.30922857 0.65788514 311.75 1.03929382e+00 3.71549565e-01 1.10371225e+00 0.34334237 0.65152973 312.00 1.24018515e+00 4.26726591e-01 1.31154672e+00 0.33139383 0.72837306 312.25 1.14846257e+00 6.53117194e-01 1.32118445e+00 0.51707791 0.63606694 312.50 8.34822916e-01 1.12964644e+00 1.40464600e+00 0.93436434 0.57600022 312.75 3.88602898e-01 1.46635090e+00 1.51696973e+00 1.31173791 0.48814107 313.00 2.26649311e-01 1.77364348e+00 1.78806630e+00 1.44369775 0.50914171 313.25 -8.70948752e-04 1.62307324e+00 1.62307348e+00 1.57133293 0.39954704 313.50 7.06191588e-02 1.51407811e+00 1.51572412e+00 1.52418842 0.46619894 313.75 -2.21417304e-01 1.37319557e+00 1.39093195e+00 1.73066271 0.66858332 314.00 -3.12324726e-01 1.12899902e+00 1.17140323e+00 1.84068531 0.73755629 314.25 -3.90270755e-01 8.84702727e-01 9.66959243e-01 1.98625126 0.74314190 314.50 -3.78136995e-01 7.47456927e-01 8.37663085e-01 2.03915123 0.73618616 314.75 -5.32119212e-01 6.21140768e-01 8.17903851e-01 2.27915603 0.75859329 315.00 -5.87297073e-01 5.66169568e-01 8.15760891e-01 2.37450897 0.79498124 315.25 -5.11537644e-01 4.40824834e-01 6.75275718e-01 2.43030838 0.65956636 315.50 -5.22282351e-01 3.86327641e-01 6.49636745e-01 2.50472191 0.73218705 315.75 -4.46420548e-01 2.89426420e-01 5.32032855e-01 2.56639455 0.66261801 316.00 -4.43410269e-01 2.35564964e-01 5.02099113e-01 2.65325297 0.68866908 316.25 -5.29157279e-01 2.11915199e-01 5.70013577e-01 2.76067533 0.74283572 316.50 -5.76306153e-01 2.12701328e-01 6.14305003e-01 2.78802486 0.78716100 316.75 -5.43192169e-01 2.70867827e-01 6.06981970e-01 2.67901818 0.81436230 317.00 -5.42564730e-01 2.84379875e-01 6.12575220e-01 2.65882007 0.79935265 317.25 -5.21480189e-01 2.58801805e-01 5.82168327e-01 2.68092298 0.77097286 317.50 -4.90074945e-01 2.86031996e-01 5.67439648e-01 2.61328234 0.75357327 317.75 -5.23078721e-01 3.60838441e-01 6.35464971e-01 2.53772091 0.72980663 318.00 -4.49066044e-01 3.87338061e-01 5.93035484e-01 2.42986256 0.73694393 318.25 -3.60737559e-01 3.72585819e-01 5.18605610e-01 2.34003896 0.73131782 318.50 -3.23935602e-01 3.87417751e-01 5.05001770e-01 2.26718890 0.70604464 318.75 -2.80854796e-01 3.74292640e-01 4.67947002e-01 2.21452877 0.70069082 319.00 -2.33938747e-01 3.31022332e-01 4.05343215e-01 2.18601540 0.59152922 319.25 -1.89479122e-01 3.41148655e-01 3.90236777e-01 2.07778751 0.62342626 319.50 -1.53868108e-01 3.13776541e-01 3.49472620e-01 2.02671417 0.52804389 319.75 -1.26580139e-01 2.52752969e-01 2.82677545e-01 2.03508832 0.47575406 320.00 -1.26037001e-01 2.41109228e-01 2.72064303e-01 2.05246858 0.51340627 320.25 -1.40136081e-01 2.14856402e-01 2.56517825e-01 2.14873856 0.54877966 320.50 -1.52207125e-01 2.12361923e-01 2.61274942e-01 2.19266545 0.54612938 320.75 -1.73265303e-01 2.05256497e-01 2.68609558e-01 2.27187874 0.64089132 321.00 -1.49823821e-01 2.08844772e-01 2.57027851e-01 2.19310046 0.55811478 321.25 -7.34670973e-02 1.93268567e-01 2.06761102e-01 1.93405655 0.52317016 321.50 -6.48958571e-02 2.06551515e-01 2.16506352e-01 1.87521761 0.48895481 321.75 -3.26973514e-02 1.59974973e-01 1.63282298e-01 1.77240985 0.38276571 322.00 -9.68921129e-03 1.42071881e-01 1.42401897e-01 1.63889025 0.29686065 322.25 -1.28215139e-03 1.24863445e-01 1.24870027e-01 1.58106439 0.32730823 322.50 -2.05393260e-03 5.99678298e-02 6.00029936e-02 1.60503352 0.06621541 322.75 2.01378600e-03 1.06066480e-02 1.07961251e-02 1.38316880 0.00245757 323.00 -1.19553509e-02 1.02047586e-02 1.57183814e-02 2.43502823 0.00312477 323.25 7.30522587e-03 -2.09104280e-03 7.59860415e-03 -0.27878499 0.00105265 323.50 9.26892058e-03 -1.04466678e-02 1.39658783e-02 -0.84506411 0.00265468 323.75 -3.68580150e-03 -3.03275651e-02 3.05507175e-02 -1.69173627 0.01731893 324.00 -7.10844811e-03 -8.07254520e-02 8.10378223e-02 -1.65862687 0.07551666 324.25 7.41650495e-03 -7.09686182e-02 7.13550931e-02 -1.46667028 0.08353263 324.50 -3.46958895e-02 -8.68782942e-02 9.35502151e-02 -1.95075258 0.13630364 324.75 -5.22064351e-02 -9.00089929e-02 1.04053499e-01 -2.09639026 0.20214169 325.00 -5.06509732e-02 -8.04008044e-02 9.50253146e-02 -2.13296942 0.13619490 325.25 -5.48266029e-02 -8.47053336e-02 1.00900693e-01 -2.14524485 0.17150206 325.50 -7.12521504e-02 -8.05212442e-02 1.07519950e-01 -2.29519832 0.16621302 325.75 -7.88532102e-02 -9.68066221e-02 1.24857322e-01 -2.25434259 0.25844595 326.00 -8.20273118e-02 -8.30394596e-02 1.16722028e-01 -2.35006282 0.21939670 326.25 -6.75163233e-02 -8.82237525e-02 1.11094034e-01 -2.22400834 0.23630473 326.50 -1.07277764e-01 -8.02711821e-02 1.33985004e-01 -2.49920893 0.35733794 326.75 -1.14168731e-01 -7.37213784e-02 1.35901953e-01 -2.56822997 0.36994743 327.00 -1.12218624e-01 -8.64187519e-02 1.41637637e-01 -2.48535569 0.25890707 327.25 -9.65590212e-02 -9.16147635e-02 1.33104881e-01 -2.38246340 0.25383098 327.50 -2.74615351e-02 -7.95265742e-02 8.41344870e-02 -1.90328928 0.10165641 327.75 -1.96361070e-02 -8.96351839e-02 9.17607916e-02 -1.78645649 0.11531403 328.00 -5.93106000e-02 -1.43498367e-01 1.55272433e-01 -1.96273160 0.22659749 328.25 -7.89772632e-02 -1.58635139e-01 1.77207549e-01 -2.03272629 0.27980455 328.50 -1.13617589e-01 -2.45168429e-01 2.70215683e-01 -2.00475961 0.45924047 328.75 -1.31962639e-01 -2.42792715e-01 2.76337548e-01 -2.06865070 0.48712973 329.00 -1.66830465e-01 -1.81034112e-01 2.46182359e-01 -2.31538619 0.42258343 329.25 -2.20571437e-01 -1.44742634e-01 2.63822268e-01 -2.56085966 0.42821115 329.50 -2.48890783e-01 -1.06662476e-01 2.70783134e-01 -2.73671785 0.50886422 329.75 -2.19229240e-01 -8.72193840e-02 2.35942113e-01 -2.76294491 0.43468021 330.00 -1.36806208e-01 -7.62034653e-02 1.56597914e-01 -2.63337762 0.25336098 330.25 -1.24208119e-01 -8.50311831e-02 1.50525609e-01 -2.54128650 0.23064450 330.50 -1.41101833e-01 -1.07408816e-01 1.77331275e-01 -2.49095257 0.34258759 330.75 -1.53456264e-01 -1.31452761e-01 2.02061014e-01 -2.43327142 0.35195035 331.00 -2.00968501e-01 -1.32757890e-01 2.40858871e-01 -2.55780840 0.47917350 331.25 -2.55909171e-01 -1.19891948e-01 2.82601456e-01 -2.70346588 0.49378454 331.50 -3.39293189e-01 -1.09558230e-01 3.56542948e-01 -2.82926008 0.64996176 331.75 -3.82683648e-01 -4.08034321e-02 3.84852822e-01 -3.03536954 0.60580536 332.00 -4.07293424e-01 7.34945095e-02 4.13871207e-01 2.96306765 0.71915781 332.25 -3.74497166e-01 1.44837165e-01 4.01529490e-01 2.77255972 0.62319251 332.50 -3.13918294e-01 2.01420851e-01 3.72981306e-01 2.57112068 0.68480697 332.75 -2.03073088e-01 2.22506510e-01 3.01243799e-01 2.31056276 0.54601953 333.00 -7.38634340e-02 2.38469200e-01 2.49646483e-01 1.87116471 0.55619721 333.25 -2.47190685e-02 2.02421235e-01 2.03924959e-01 1.69231165 0.44573263 333.50 4.73729330e-03 1.76145956e-01 1.76209647e-01 1.54390867 0.56102588 333.75 -2.21363157e-02 1.55526060e-01 1.57093513e-01 1.71217858 0.38333197 334.00 -6.00379643e-02 1.66212200e-01 1.76723095e-01 1.91742509 0.49325780 334.25 -6.02109349e-02 2.09982808e-01 2.18444813e-01 1.85004607 0.53647552 334.50 -3.81114238e-02 2.57067233e-01 2.59876976e-01 1.71797894 0.68179807 334.75 4.98706867e-02 2.38324077e-01 2.43486039e-01 1.36451704 0.53672736 335.00 7.36875207e-02 1.75438862e-01 1.90285693e-01 1.17315284 0.44358607 335.25 9.54992240e-02 1.38964141e-01 1.68615344e-01 0.96869774 0.30986156 335.50 6.16289267e-02 1.40377978e-01 1.53310474e-01 1.15710968 0.33254164 335.75 4.17760394e-02 1.44301981e-01 1.50227492e-01 1.28899624 0.30102213 336.00 3.99046391e-02 1.66841443e-01 1.71547216e-01 1.33602965 0.38990974 336.25 3.83495796e-02 1.42426320e-01 1.47498972e-01 1.30777520 0.37548148 336.50 4.16376077e-02 1.51682648e-01 1.57293726e-01 1.30289060 0.48061580 336.75 3.21986615e-02 1.98331323e-01 2.00928016e-01 1.40985267 0.52794422 337.00 4.29860784e-02 2.12179326e-01 2.16489883e-01 1.37090860 0.61176004 337.25 6.17636700e-02 2.61869854e-01 2.69054960e-01 1.33917298 0.69975629 337.50 6.00365466e-02 2.90679706e-01 2.96814889e-01 1.36712174 0.77689103 337.75 6.77634685e-02 3.38891963e-01 3.45600420e-01 1.37344311 0.75726940 338.00 8.45467202e-02 3.65230916e-01 3.74889010e-01 1.34331478 0.78962984 338.25 6.79088905e-02 3.67363389e-01 3.73587309e-01 1.38800495 0.78654219 338.50 4.22014401e-02 4.41364528e-01 4.43377500e-01 1.47547028 0.78469054 338.75 1.04866437e-01 6.79187113e-01 6.87235115e-01 1.41760608 0.81510486 339.00 2.32245222e-01 7.29951697e-01 7.66007391e-01 1.26275864 0.79624776 339.25 5.31581190e-01 6.78169265e-01 8.61679821e-01 0.90598245 0.89095652 339.50 6.00737880e-01 6.79136460e-01 9.06704104e-01 0.84657663 0.89958745 339.75 6.99096301e-01 6.68980683e-01 9.67610868e-01 0.76338862 0.88599462 340.00 7.39149391e-01 6.27025077e-01 9.69279252e-01 0.70350996 0.87039936 340.25 9.51708002e-01 6.77346566e-01 1.16813804e+00 0.61854638 0.90957056 340.50 1.00914131e+00 7.06310266e-01 1.23176312e+00 0.61066700 0.88805428 340.75 1.17611169e+00 6.82794410e-01 1.35994372e+00 0.52599701 0.87991168 341.00 1.29805913e+00 6.60825678e-01 1.45658782e+00 0.47089115 0.85629424 341.25 1.47481538e+00 6.97177912e-01 1.63129931e+00 0.44158818 0.79942399 341.50 1.61310330e+00 3.32999695e-01 1.64711598e+00 0.20357457 0.71137385 341.75 1.99469264e+00 -2.21940276e-01 2.00700180e+00 -0.11080963 0.85002596 342.00 1.96103593e+00 -4.24652572e-01 2.00648741e+00 -0.21325245 0.86535300 342.25 1.83497418e+00 -7.36247608e-01 1.97716736e+00 -0.38156670 0.88560067 342.50 1.70896044e+00 -9.24191472e-01 1.94285245e+00 -0.49574595 0.84132838 342.75 1.53223374e+00 -1.16939163e+00 1.92748982e+00 -0.65189194 0.90120088 343.00 1.29204541e+00 -1.20148056e+00 1.76435169e+00 -0.74909413 0.90502665 343.25 1.09624772e+00 -1.22653809e+00 1.64503944e+00 -0.84143173 0.92674673 343.50 1.05754958e+00 -1.05915904e+00 1.49673946e+00 -0.78615852 0.92905725 343.75 1.01234998e+00 -8.95459005e-01 1.35155440e+00 -0.72420491 0.94529479 344.00 1.14392030e+00 -7.90718757e-01 1.39060771e+00 -0.60481975 0.93524224 344.25 1.26414603e+00 -7.18185025e-01 1.45391022e+00 -0.51664744 0.94694692 344.50 1.53659059e+00 -7.85461857e-01 1.72570594e+00 -0.47254509 0.89207023 344.75 1.86208903e+00 -1.07901613e+00 2.15212717e+00 -0.52518366 0.92193934 345.00 1.66456357e+00 -1.73580032e+00 2.40494795e+00 -0.80634484 0.89272278 345.25 1.27456119e+00 -1.89671110e+00 2.28517379e+00 -0.97912091 0.92498429 345.50 1.11542798e+00 -1.81952087e+00 2.13420612e+00 -1.02084816 0.93621912 345.75 1.00695277e+00 -1.74013362e+00 2.01047728e+00 -1.04621277 0.94693010 346.00 1.03865710e+00 -1.68307241e+00 1.97776169e+00 -1.01788384 0.96382091 346.25 1.05265225e+00 -1.63984256e+00 1.94863039e+00 -1.00012029 0.97429021 346.50 1.09154406e+00 -1.68114604e+00 2.00442522e+00 -0.99492342 0.97047852 346.75 1.10486913e+00 -1.73077781e+00 2.05336983e+00 -1.00264343 0.96346906 347.00 1.19908007e+00 -1.88619966e+00 2.23507096e+00 -1.00453094 0.96012499 347.25 1.29434435e+00 -1.98882097e+00 2.37291722e+00 -0.99385198 0.96865751 347.50 1.35393408e+00 -2.19247640e+00 2.57683726e+00 -1.01758207 0.96213703 347.75 1.38974741e+00 -2.43027957e+00 2.79958151e+00 -1.05133505 0.95231587 348.00 1.19344042e+00 -2.94849248e+00 3.18086591e+00 -1.18619074 0.92868271 348.25 1.08217508e+00 -3.28796888e+00 3.46147978e+00 -1.25283192 0.93929719 348.50 6.56550159e-01 -3.68654771e+00 3.74455500e+00 -1.39455068 0.94539582 348.75 3.75283742e-01 -3.89380012e+00 3.91184320e+00 -1.47471328 0.95296561 349.00 -3.30741570e-01 -4.08356348e+00 4.09693552e+00 -1.65161329 0.95358132 349.25 -6.65422562e-01 -4.09968374e+00 4.15333528e+00 -1.73170380 0.94920793 349.50 -1.48770734e+00 -3.99946309e+00 4.26719793e+00 -1.92691386 0.95548478 349.75 -1.72719889e+00 -3.91271914e+00 4.27698340e+00 -1.98650218 0.95893313 350.00 -2.24669180e+00 -3.53362844e+00 4.18738032e+00 -2.13712645 0.95854148 350.25 -2.53238308e+00 -3.30567683e+00 4.16418820e+00 -2.22450377 0.95712321 350.50 -2.71966826e+00 -2.82781703e+00 3.92340982e+00 -2.33670186 0.95894158 350.75 -2.88683489e+00 -2.53354716e+00 3.84092136e+00 -2.42128008 0.94470725 351.00 -3.23472923e+00 -1.87233347e+00 3.73752669e+00 -2.61689054 0.95188772 351.25 -3.34520597e+00 -1.43380069e+00 3.63953121e+00 -2.73666526 0.94793021 351.50 -3.37564905e+00 -8.18219397e-01 3.47339740e+00 -2.90379024 0.95366360 351.75 -3.15424534e+00 -5.23511593e-01 3.19739395e+00 -2.97712143 0.94420742 352.00 -2.92408690e+00 -1.82200434e-01 2.92975787e+00 -3.07936291 0.92377804 352.25 -2.38806195e+00 2.10415936e-01 2.39731407e+00 3.05370803 0.85737833 352.50 -1.95830121e+00 4.14687086e-01 2.00172650e+00 2.93291675 0.93468775 352.75 -1.76552880e+00 3.62345491e-01 1.80232799e+00 2.93917007 0.91521889 353.00 -1.42030933e+00 3.63059232e-01 1.46597769e+00 2.89133177 0.91338064 353.25 -1.17292966e+00 2.50471832e-01 1.19937489e+00 2.93120879 0.84583583 353.50 -9.75010635e-01 1.97745075e-01 9.94861223e-01 2.94149352 0.88233286 353.75 -9.23452697e-01 1.71071818e-01 9.39164762e-01 2.95841686 0.84512627 354.00 -9.26610415e-01 9.03944564e-02 9.31009140e-01 3.04434647 0.89065105 354.25 -9.33394835e-01 7.04816388e-02 9.36052124e-01 3.06622462 0.85477350 354.50 -8.55580019e-01 1.38672124e-01 8.66745134e-01 2.98091030 0.79626145 354.75 -7.58111208e-01 2.93163058e-01 8.12820511e-01 2.77260244 0.66554620 355.00 -3.79918527e-01 4.90842283e-01 6.20696572e-01 2.22948975 0.46895378 355.25 3.48348663e-01 5.25325604e-01 6.30328313e-01 0.98526007 0.27930763 355.50 1.16930301e+00 1.22940324e-01 1.17574821e+00 0.10475497 0.49401382 355.75 1.48485084e+00 -1.22321471e+00 1.92380775e+00 -0.68908343 0.50516565 356.00 1.51813123e+00 -2.56017385e+00 2.97644294e+00 -1.03555477 0.58364726 356.25 -1.62597793e+00 -2.99540354e+00 3.40826153e+00 -2.06811370 0.61948420 356.50 -2.93972282e+00 -2.29520711e+00 3.72960399e+00 -2.47869631 0.78433176 356.75 -2.86376922e+00 -4.53237670e-01 2.89941348e+00 -2.98462844 0.79282715 357.00 -2.87910478e+00 2.12873149e-02 2.87918347e+00 3.13419906 0.90867506 357.25 -2.33107449e+00 3.32019955e-01 2.35460093e+00 3.00011212 0.90883133 357.50 -1.91983017e+00 3.50804904e-01 1.95161778e+00 2.96085951 0.90053895 357.75 -1.70175641e+00 3.87036193e-01 1.74521399e+00 2.91796331 0.72161650 358.00 -1.34968379e+00 9.04942811e-01 1.62498241e+00 2.55095121 0.44080711 358.25 -2.04068634e-01 7.15798403e-01 7.44319395e-01 1.84852087 0.33534032 358.50 -9.00376850e-02 5.01357390e-01 5.09378069e-01 1.74849000 0.49457347 358.75 -1.14989195e-01 1.84612489e-01 2.17495486e-01 2.12786098 0.32604257 359.00 -1.32266289e-01 7.86610839e-02 1.53889367e-01 2.60506636 0.24522108 359.25 -1.67724781e-01 -1.72677483e-01 2.40726225e-01 -2.34164596 0.52284983 359.50 -2.29973855e-01 -2.67701144e-01 3.52919080e-01 -2.28053212 0.75042357 359.75 -3.47136732e-01 -3.77172031e-01 5.12603796e-01 -2.31475070 0.92218953 360.00 -3.95462738e-01 -3.87976297e-01 5.54000347e-01 -2.36575007 0.93126557 360.25 -4.78651305e-01 -3.78077230e-01 6.09958575e-01 -2.47305280 0.96655142 360.50 -5.03066431e-01 -3.76607548e-01 6.28417918e-01 -2.49897284 0.97116995 360.75 -5.13969097e-01 -3.89266511e-01 6.44742312e-01 -2.49338926 0.97559869 361.00 -5.31434064e-01 -3.87435414e-01 6.57668886e-01 -2.51164301 0.95824566 361.25 -5.92720257e-01 -3.46261058e-01 6.86450306e-01 -2.61287951 0.93912308 361.50 -5.90572794e-01 -3.17994364e-01 6.70743349e-01 -2.64765965 0.89531056 361.75 -5.33753516e-01 -1.21325111e-01 5.47368795e-01 -2.91808489 0.88842582 362.00 -4.57037901e-01 -8.35342148e-02 4.64609091e-01 -2.96081499 0.78797647 362.25 -1.92545066e-01 -9.16969451e-02 2.13264935e-01 -2.69713611 0.54861863 362.50 -1.40134961e-01 -1.70060261e-01 2.20359478e-01 -2.26001964 0.61090419 362.75 -9.87784431e-02 -3.01525652e-01 3.17293081e-01 -1.88737396 0.81328596 363.00 -3.64392169e-02 -3.96752620e-01 3.98422462e-01 -1.66238305 0.76947263 363.25 5.04958669e-02 -5.87969702e-01 5.90134055e-01 -1.48512479 0.82067255 363.50 -3.85160379e-02 -7.65577906e-01 7.66546160e-01 -1.62106370 0.86373171 363.75 -1.58151001e-01 -9.09519301e-01 9.23166885e-01 -1.74295911 0.92500443 364.00 -3.09370231e-01 -8.96404009e-01 9.48287977e-01 -1.90312038 0.90846337 364.25 -4.70617597e-01 -8.95404865e-01 1.01154871e+00 -2.05470727 0.94114290 364.50 -4.34586988e-01 -7.31089790e-01 8.50504633e-01 -2.10711551 0.89554464 364.75 -2.37052474e-01 -5.77432221e-01 6.24196960e-01 -1.96034605 0.71845546 365.00 1.63998931e-03 -7.85722659e-01 7.85724371e-01 -1.56870909 0.60686305 365.25 -1.30493195e-01 -1.43197801e+00 1.43791150e+00 -1.66167326 0.68192861 365.50 -1.04923247e+00 -1.21381021e+00 1.60443884e+00 -2.28359820 0.73201174 365.75 -1.22268464e+00 -7.89676601e-01 1.45552288e+00 -2.56813706 0.87114991 366.00 -7.32963041e-01 -5.48539732e-01 9.15494761e-01 -2.49912491 0.81987174 366.25 -6.05156867e-01 -5.65507975e-01 8.28259683e-01 -2.39005025 0.86044069 366.50 -3.67989436e-01 -8.74765408e-01 9.49015671e-01 -1.96899553 0.86088269 366.75 -2.96202365e-01 -1.05473706e+00 1.09553918e+00 -1.84457501 0.91930047 367.00 -3.14257786e-01 -1.31906517e+00 1.35598336e+00 -1.80467915 0.91778513 367.25 -2.96329274e-01 -1.48679747e+00 1.51604016e+00 -1.76752554 0.94757475 367.50 -4.65387398e-01 -1.73278083e+00 1.79418919e+00 -1.83318262 0.92033927 367.75 -7.05877785e-01 -1.97938152e+00 2.10147916e+00 -1.91335233 0.91291292 368.00 -1.21788729e+00 -2.19584990e+00 2.51097715e+00 -2.07718836 0.87515749 368.25 -1.50405550e+00 -2.17380106e+00 2.64340576e+00 -2.17606613 0.88344790 368.50 -9.56915390e-01 -2.43286315e+00 2.61428961e+00 -1.94553856 0.76778018 368.75 -3.19547179e-01 -2.60466342e+00 2.62419167e+00 -1.69286904 0.55975065 369.00 5.27874264e-01 -1.34763731e-01 5.44805012e-01 -0.24995608 0.00992615 369.25 -1.44776564e-01 2.75234141e+00 2.75614649e+00 1.62334913 0.32068394 369.50 -3.40576599e-03 2.57961996e+00 2.57962221e+00 1.57211658 0.75952468 369.75 1.33214892e-01 2.07384753e+00 2.07812169e+00 1.50664883 0.77209573 370.00 -1.51874682e-01 1.30595038e+00 1.31475181e+00 1.68657064 0.88253475 370.25 -1.34123770e-01 1.10301378e+00 1.11113842e+00 1.69179982 0.89792834 370.50 -2.69484309e-01 7.20934754e-01 7.69654931e-01 1.92851319 0.90869755 370.75 -3.16544154e-01 6.43751636e-01 7.17367668e-01 2.02779627 0.91386863 371.00 -3.30498491e-01 5.49005036e-01 6.40808694e-01 2.11268172 0.92520845 371.25 -3.28299876e-01 4.73156618e-01 5.75897555e-01 2.17738306 0.90159514 371.50 -3.04809748e-01 2.90771918e-01 4.21256799e-01 2.37976008 0.87954808 371.75 -3.17846161e-01 2.21992220e-01 3.87694116e-01 2.53192343 0.86641092 372.00 -4.22161365e-01 1.18465434e-01 4.38468102e-01 2.86801239 0.92782125 372.25 -4.74964466e-01 1.10523737e-01 4.87654325e-01 2.91296242 0.95802476 372.50 -5.45528749e-01 1.04989261e-01 5.55539702e-01 2.95146315 0.97552663 372.75 -5.65250395e-01 1.30492301e-01 5.80117445e-01 2.91470999 0.96797224 373.00 -5.84683265e-01 1.82329127e-01 6.12452799e-01 2.83930684 0.97080126 373.25 -5.61131229e-01 1.99758164e-01 5.95627048e-01 2.79958986 0.96114417 373.50 -5.09359729e-01 2.12812303e-01 5.52029356e-01 2.74583322 0.95646981 373.75 -4.71744232e-01 2.13751613e-01 5.17911549e-01 2.71615619 0.95476536 374.00 -4.41653468e-01 2.14384499e-01 4.90936350e-01 2.68968229 0.96927566 374.25 -4.22553545e-01 1.81601414e-01 4.59924528e-01 2.73568757 0.95712683 374.50 -3.99626181e-01 1.39203171e-01 4.23176805e-01 2.80640327 0.95544808 374.75 -3.97135456e-01 1.05375955e-01 4.10877916e-01 2.88222918 0.93445281 375.00 -4.19186945e-01 6.55911749e-02 4.24287517e-01 2.98637885 0.93359860 375.25 -4.48147633e-01 6.49915446e-02 4.52835734e-01 2.99757408 0.92564294 375.50 -4.93355951e-01 8.31574209e-02 5.00315151e-01 2.97460762 0.93567774 375.75 -4.94457829e-01 1.37300060e-01 5.13166494e-01 2.87073844 0.92594265 376.00 -4.86396510e-01 1.88035398e-01 5.21477589e-01 2.77270093 0.95314058 376.25 -4.42201547e-01 2.26880896e-01 4.97008199e-01 2.66754282 0.94898183 376.50 -4.00196961e-01 2.50597449e-01 4.72182898e-01 2.58214145 0.96887939 376.75 -3.72638699e-01 2.49182071e-01 4.48275924e-01 2.55218632 0.97023800 377.00 -3.60215584e-01 2.40316430e-01 4.33021077e-01 2.55325819 0.97731980 377.25 -3.50504936e-01 2.43807093e-01 4.26960898e-01 2.53383378 0.96010784 377.50 -3.40387107e-01 2.50210502e-01 4.22455534e-01 2.50771131 0.96757095 377.75 -2.96725206e-01 2.79236135e-01 4.07453883e-01 2.38655017 0.94568907 378.00 -2.73746546e-01 3.02702440e-01 4.08124905e-01 2.30600518 0.95119350 378.25 -1.86746695e-01 3.12246017e-01 3.63829498e-01 2.10979956 0.91598847 378.50 -1.49219200e-01 3.26089068e-01 3.58609049e-01 1.99995455 0.93155060 378.75 -9.63150682e-02 3.39580796e-01 3.52975508e-01 1.84716731 0.90449097 379.00 -5.40286059e-02 3.63945129e-01 3.67933618e-01 1.71817260 0.89514804 379.25 5.13425727e-02 3.26974091e-01 3.30980537e-01 1.41504474 0.85264766 379.50 9.28152590e-02 2.91213781e-01 3.05647082e-01 1.26225616 0.86106073 379.75 1.71798289e-01 2.22097150e-01 2.80787813e-01 0.91240677 0.80160643 380.00 1.99839907e-01 1.78995414e-01 2.68282214e-01 0.73043102 0.81553523 380.25 1.74192675e-01 1.26556526e-01 2.15312894e-01 0.62831154 0.77640046 380.50 1.72289029e-01 1.00651495e-01 1.99535042e-01 0.52872189 0.73099272 380.75 2.20809737e-01 1.04025994e-01 2.44086761e-01 0.44027085 0.76679212 381.00 2.39806279e-01 1.10215602e-01 2.63921447e-01 0.43081074 0.76648861 381.25 2.99035934e-01 1.79058563e-01 3.48546208e-01 0.53952646 0.83631519 381.50 3.55838484e-01 1.72021753e-01 3.95237283e-01 0.45030112 0.85752805 381.75 4.95235793e-01 1.48293533e-01 5.16961761e-01 0.29094319 0.89412717 382.00 5.85131512e-01 1.44595208e-01 6.02732661e-01 0.24226223 0.88817258 382.25 8.02063972e-01 3.84803875e-02 8.02986522e-01 0.04793995 0.91837502 382.50 8.92237321e-01 -8.53055137e-02 8.96306013e-01 -0.09531882 0.90022549 382.75 9.37954129e-01 -3.60153768e-01 1.00472319e+00 -0.36661848 0.93222217 383.00 9.37097387e-01 -5.23862213e-01 1.07358424e+00 -0.50974687 0.92692029 383.25 8.97681645e-01 -7.77998234e-01 1.18790302e+00 -0.71409545 0.94625591 383.50 7.21337330e-01 -9.53747115e-01 1.19580981e+00 -0.92326313 0.92721825 383.75 5.28200765e-01 -1.06075215e+00 1.18498573e+00 -1.10879064 0.96885247 384.00 4.08485153e-01 -1.05014703e+00 1.12679585e+00 -1.19982676 0.95969986 384.25 2.55122298e-01 -1.01549586e+00 1.04705264e+00 -1.32466103 0.97694519 384.50 1.57277079e-01 -9.87730054e-01 1.00017335e+00 -1.41289112 0.96830748 384.75 5.53851268e-02 -9.53188035e-01 9.54795760e-01 -1.51275644 0.98298798 385.00 2.79644749e-02 -9.17644224e-01 9.18070223e-01 -1.54033155 0.97560879 385.25 -3.81172124e-03 -8.69079241e-01 8.69087600e-01 -1.57518223 0.97962069 385.50 4.40806583e-03 -8.35236562e-01 8.35248194e-01 -1.56551875 0.97504118 385.75 1.81514819e-02 -8.10635681e-01 8.10838876e-01 -1.54840840 0.97742808 386.00 4.19710690e-02 -8.17233778e-01 8.18310832e-01 -1.51948393 0.97300714 386.25 5.90087671e-02 -8.36348387e-01 8.38427491e-01 -1.50035781 0.98465023 386.50 7.84227992e-02 -8.96585139e-01 9.00008360e-01 -1.48355005 0.97890498 386.75 7.06482881e-02 -9.62377179e-01 9.64966847e-01 -1.49751759 0.97788332 387.00 -6.82031230e-03 -1.02557590e+00 1.02559857e+00 -1.57744646 0.97139403 387.25 -6.03493120e-02 -1.05071415e+00 1.05244585e+00 -1.62816976 0.98148413 387.50 -1.24328759e-01 -1.03155089e+00 1.03901630e+00 -1.69074381 0.97499721 387.75 -1.75069958e-01 -1.01633961e+00 1.03130776e+00 -1.74137769 0.97878782 388.00 -1.93202756e-01 -9.65174849e-01 9.84321997e-01 -1.76835904 0.96846028 388.25 -2.00124444e-01 -9.42578155e-01 9.63588798e-01 -1.78000568 0.96885400 388.50 -2.33846190e-01 -9.40506044e-01 9.69141713e-01 -1.81449335 0.96325825 388.75 -2.57595122e-01 -9.52763070e-01 9.86971486e-01 -1.83484963 0.96880329 389.00 -2.95680925e-01 -1.04198039e+00 1.08312065e+00 -1.84729587 0.94943677 389.25 -3.74402126e-01 -1.09472573e+00 1.15697942e+00 -1.90033134 0.95824339 389.50 -5.41240821e-01 -9.73041497e-01 1.11344123e+00 -2.07841473 0.92161166 389.75 -6.66414891e-01 -9.21782239e-01 1.13744947e+00 -2.19676835 0.92844790 390.00 -7.45266802e-01 -6.76241079e-01 1.00634219e+00 -2.40471448 0.88551625 390.25 -7.07711609e-01 -5.33342158e-01 8.86176946e-01 -2.49578189 0.85780667 390.50 -6.14944117e-01 -4.04112977e-01 7.35842079e-01 -2.56020470 0.85166156 390.75 -5.47430264e-01 -4.25078526e-01 6.93088484e-01 -2.48134736 0.83482263 391.00 -3.85872063e-01 -3.92823355e-01 5.50642750e-01 -2.34726788 0.79814763 391.25 -3.40863940e-01 -3.71671050e-01 5.04309027e-01 -2.31298547 0.79921610 391.50 -2.06872899e-01 -4.26410396e-01 4.73943269e-01 -2.02249332 0.75911202 391.75 -1.80276388e-01 -4.47448483e-01 4.82399960e-01 -1.95379904 0.80085486 392.00 -2.42351445e-01 -5.00284819e-01 5.55894885e-01 -2.02190805 0.80905300 392.25 -2.35795378e-01 -5.71997281e-01 6.18692452e-01 -1.96180255 0.81818984 392.50 -2.35036904e-01 -6.29398426e-01 6.71851713e-01 -1.92819075 0.83271068 392.75 -2.90974306e-01 -5.75998430e-01 6.45321810e-01 -2.03856748 0.76841840 393.00 -3.89947668e-01 -5.03559804e-01 6.36892189e-01 -2.22972021 0.75556981 393.25 -4.07467136e-01 -4.84587650e-01 6.33130837e-01 -2.26995625 0.75424143 393.50 -3.71886592e-01 -4.55494953e-01 5.88026607e-01 -2.25548460 0.77124644 393.75 -3.38860373e-01 -4.50350299e-01 5.63597147e-01 -2.21585550 0.72518790 394.00 -3.57336489e-01 -4.47665896e-01 5.72795008e-01 -2.24445180 0.73834123 394.25 -2.79234226e-01 -4.35348641e-01 5.17204208e-01 -2.14110469 0.68100667 394.50 -2.11990215e-01 -4.18366249e-01 4.69009776e-01 -2.03979724 0.64895596 394.75 -2.80140199e-01 -4.84820811e-01 5.59937274e-01 -2.09474893 0.62404702 395.00 -4.51092133e-01 -5.05308169e-01 6.77362871e-01 -2.29956750 0.69517859 395.25 -5.78648601e-01 -2.69837315e-01 6.38471910e-01 -2.70524751 0.56036027 395.50 -6.12326528e-01 3.29545903e-02 6.13212673e-01 3.08782587 0.61749801 395.75 -3.66899715e-01 2.51932527e-01 4.45067859e-01 2.53988117 0.51914284 396.00 -1.92674674e-01 2.94811679e-01 3.52189517e-01 2.14966430 0.58958397 396.25 -8.60354184e-02 2.37206521e-01 2.52327222e-01 1.91874236 0.53413895 396.50 -2.46057121e-02 2.15524803e-01 2.16924830e-01 1.68447065 0.58965802 396.75 4.27177956e-02 2.00561464e-01 2.05060262e-01 1.36094115 0.53623178 397.00 5.74536842e-02 1.87096955e-01 1.95719688e-01 1.27285708 0.59481790 397.25 7.00689334e-02 2.06442210e-01 2.18009269e-01 1.24358511 0.47950311 397.50 1.37404300e-01 2.59394932e-01 2.93539900e-01 1.08366354 0.59099358 397.75 3.01652418e-01 3.04286519e-01 4.28467580e-01 0.78974528 0.67651199 398.00 4.85037432e-01 2.76768030e-01 5.58445927e-01 0.51853010 0.80447075 398.25 6.87583166e-01 1.63724706e-01 7.06807180e-01 0.23376304 0.90156673 398.50 7.64875070e-01 1.36816584e-01 7.77015219e-01 0.17700247 0.94067055 398.75 7.87076899e-01 -5.65638397e-03 7.87097224e-01 -0.00718645 0.92409082 399.00 8.17673416e-01 -8.80456958e-02 8.22400061e-01 -0.10726502 0.94500293 399.25 8.39653960e-01 -1.33398850e-01 8.50184701e-01 -0.15755679 0.94455057 399.50 8.56445548e-01 -1.77314918e-01 8.74608230e-01 -0.20415154 0.96360898 399.75 8.75959860e-01 -2.14953063e-01 9.01948167e-01 -0.24063653 0.95519928 400.00 8.93955976e-01 -2.66851709e-01 9.32934682e-01 -0.29008609 0.96276917 400.25 9.06923265e-01 -3.33688549e-01 9.66363212e-01 -0.35256210 0.96779077 400.50 9.02514883e-01 -3.56467488e-01 9.70361883e-01 -0.37616380 0.96634182 400.75 9.36924732e-01 -3.36556575e-01 9.95539191e-01 -0.34485967 0.97710179 401.00 9.59607346e-01 -3.51342426e-01 1.02190399e+00 -0.35097292 0.97621599 401.25 1.05038696e+00 -4.42370538e-01 1.13973877e+00 -0.39860520 0.97071396 401.50 1.07910912e+00 -4.74840869e-01 1.17896156e+00 -0.41453238 0.96965038 401.75 1.11244386e+00 -5.74813526e-01 1.25217488e+00 -0.47692796 0.96763095 402.00 1.11633922e+00 -6.38039032e-01 1.28580989e+00 -0.51923451 0.95917386 402.25 1.11228623e+00 -7.84150109e-01 1.36090854e+00 -0.61406678 0.95789657 402.50 1.07031088e+00 -8.52534066e-01 1.36834927e+00 -0.67262113 0.93333905 402.75 8.45208300e-01 -9.98918208e-01 1.30851620e+00 -0.86855700 0.87984906 403.00 6.80979919e-01 -1.00971638e+00 1.21789196e+00 -0.97744046 0.81931743 403.25 3.15131601e-01 -8.51408172e-01 9.07856708e-01 -1.21630218 0.50221691 403.50 2.64193459e-01 -5.51717580e-01 6.11711101e-01 -1.12420627 0.16513604 403.75 1.08692836e+00 1.24669524e-02 1.08699986e+00 0.01146939 0.30832323 404.00 1.44303087e+00 -4.46265083e-01 1.51046040e+00 -0.29992621 0.52810235 404.25 1.81147120e+00 -8.91542398e-01 2.01897889e+00 -0.45735984 0.78278929 404.50 1.52925112e+00 -1.22467115e+00 1.95919075e+00 -0.67524723 0.77519019 404.75 1.07210439e+00 -1.64454994e+00 1.96314857e+00 -0.99307708 0.81265912 405.00 6.83390688e-01 -1.75063772e+00 1.87929648e+00 -1.19862200 0.82321177 405.25 3.21001365e-01 -1.64405155e+00 1.67509623e+00 -1.37797204 0.86093669 405.50 9.79254088e-02 -1.23686388e+00 1.24073432e+00 -1.49178879 0.80929452 405.75 -8.56514790e-02 -8.53383794e-01 8.57671310e-01 -1.67082823 0.76159774 406.00 4.32602903e-02 -4.27006939e-01 4.29192705e-01 -1.46983031 0.38890841 406.25 3.12041914e-01 -8.89026218e-02 3.24459292e-01 -0.27755224 0.37962248 406.50 6.31632679e-01 -7.79139308e-02 6.36420005e-01 -0.12273323 0.75181389 406.75 8.22106946e-01 -1.23954224e-01 8.31399110e-01 -0.14964906 0.88368285 407.00 9.42129535e-01 -2.07092461e-01 9.64621868e-01 -0.21637207 0.86408886 407.25 1.00732201e+00 -2.68908838e-01 1.04259752e+00 -0.26087081 0.92208357 407.50 1.09371735e+00 -2.29840105e-01 1.11760643e+00 -0.20713183 0.90147323 407.75 1.15497701e+00 -2.45727040e-01 1.18082754e+00 -0.20962929 0.91790218 408.00 1.18869604e+00 -2.60682996e-01 1.21694449e+00 -0.21588409 0.92108215 408.25 1.20709576e+00 -2.73789503e-01 1.23775638e+00 -0.22304295 0.92426932 408.50 1.26497203e+00 -2.91049501e-01 1.29802313e+00 -0.22614792 0.91913241 408.75 1.29057004e+00 -2.84027318e-01 1.32145471e+00 -0.21662562 0.91577883 409.00 1.34351590e+00 -2.50751971e-01 1.36671560e+00 -0.18451571 0.86151647 409.25 1.35870548e+00 -2.59219201e-01 1.38321191e+00 -0.18851847 0.89837896 409.50 1.46709923e+00 -2.49772174e-01 1.48820909e+00 -0.16863215 0.92266943 409.75 1.49043285e+00 -2.34531748e-01 1.50877276e+00 -0.15607829 0.92684524 410.00 1.45820477e+00 -2.60752733e-01 1.48133491e+00 -0.17694745 0.89963869 410.25 1.42117848e+00 -2.14161571e-01 1.43722422e+00 -0.14956758 0.90374026 410.50 1.37146939e+00 -2.31189642e-01 1.39081880e+00 -0.16700074 0.90220467 410.75 1.32070809e+00 -1.72060570e-01 1.33186887e+00 -0.12954939 0.88801096 411.00 1.32489167e+00 -4.56792930e-02 1.32567889e+00 -0.03446411 0.84086310 411.25 1.26265318e+00 7.14933922e-02 1.26467560e+00 0.05656117 0.83120011 411.50 1.35033890e+00 2.73011606e-01 1.37766124e+00 0.19949089 0.84137271 411.75 1.45960722e+00 3.83394781e-01 1.50912054e+00 0.25686721 0.83657978 412.00 1.51253513e+00 6.49245061e-01 1.64598957e+00 0.40545898 0.87948951 412.25 1.53380427e+00 6.99209341e-01 1.68565989e+00 0.42772144 0.86969463 412.50 1.69063323e+00 1.08007215e+00 2.00618956e+00 0.56850160 0.86549690 412.75 1.80471330e+00 1.24542327e+00 2.19273100e+00 0.60404720 0.86700465 413.00 2.06395012e+00 1.56425389e+00 2.58974523e+00 0.64853369 0.89603289 413.25 2.26967559e+00 1.66235160e+00 2.81333257e+00 0.63215344 0.87338576 413.50 2.43360435e+00 1.91980383e+00 3.09968980e+00 0.66791903 0.85584846 413.75 2.63784588e+00 2.15108028e+00 3.40372991e+00 0.68410206 0.85917441 414.00 3.07807767e+00 2.89710264e+00 4.22702802e+00 0.75511963 0.90983965 414.25 3.41087469e+00 3.02352113e+00 4.55804193e+00 0.72527027 0.88073764 414.50 4.15038507e+00 3.97630551e+00 5.74775624e+00 0.76398072 0.87671351 414.75 4.47427202e+00 4.23031162e+00 6.15748703e+00 0.75737884 0.83557724 415.00 5.67527467e+00 4.98927308e+00 7.55655930e+00 0.72116124 0.82184454 415.25 5.72672238e+00 4.86449787e+00 7.51389970e+00 0.70416793 0.65877211 415.50 7.53183151e+00 4.32715270e+00 8.68635346e+00 0.52146996 0.45590015 415.75 6.35805062e+00 2.32176069e+00 6.76870596e+00 0.35012366 0.27999878 416.00 6.18062613e+00 1.77459313e+00 6.43034370e+00 0.27960056 0.22057809 416.25 2.95845706e+00 2.72926617e+00 4.02509156e+00 0.74512423 0.12436653 416.50 -1.39957623e+00 4.63525321e+00 4.84194030e+00 1.86403354 0.18581042 416.75 -2.47954881e+00 3.35837951e+00 4.17455090e+00 2.20677831 0.30168762 417.00 -3.24952253e+00 2.97762661e+00 4.40745470e+00 2.39982976 0.46508138 417.25 -3.04156396e+00 2.39179269e+00 3.86933891e+00 2.47521852 0.48717045 417.50 -2.78300341e+00 2.09895883e+00 3.48579061e+00 2.49540491 0.68174251 417.75 -2.22878727e+00 1.29926014e+00 2.57983906e+00 2.61380808 0.53747267 418.00 -2.31928419e+00 1.03316460e+00 2.53899748e+00 2.72251475 0.51677876 418.25 -2.52669773e+00 2.06318384e+00 3.26204368e+00 2.45683931 0.66107964 418.50 -2.87040367e+00 2.52585180e+00 3.82349899e+00 2.41995811 0.76996768 418.75 -2.55446998e+00 2.59088808e+00 3.63840871e+00 2.34911675 0.66812657 419.00 -2.39580811e+00 3.03842645e+00 3.86935806e+00 2.23848743 0.74021546 419.25 -1.86563290e+00 2.99084439e+00 3.52501578e+00 2.12851882 0.77434425 419.50 -1.72344320e+00 3.11324631e+00 3.55844897e+00 2.07638697 0.80973686 419.75 -1.39058361e+00 2.54413858e+00 2.89937302e+00 2.07101255 0.55923657 420.00 -1.67815307e+00 1.97413128e+00 2.59102143e+00 2.27533200 0.44814258 420.25 -3.79088834e+00 1.76549830e+00 4.18184393e+00 2.70574189 0.31083755 420.50 -5.24726339e+00 3.27260983e+00 6.18415299e+00 2.58394358 0.34566416 420.75 -3.66772304e+00 5.35685743e+00 6.49215787e+00 2.17116496 0.13911355 421.00 -4.85981418e+00 4.52577047e+00 6.64081261e+00 2.39177062 0.09237384 421.25 -4.88851075e+00 4.25296850e+00 6.47960480e+00 2.42560571 0.04384794 421.50 -9.16094642e+00 3.20897239e+00 9.70672154e+00 2.80466102 0.06771454 421.75 -2.17683518e+01 -2.46323392e+00 2.19072742e+01 -3.02891529 0.36856311 422.00 -2.28509929e+01 2.74326281e+00 2.30150683e+01 3.02211439 0.55604583 422.25 -1.95540141e+01 2.28001635e+00 1.96864913e+01 3.02551588 0.72392465 422.50 -1.68906919e+01 1.14603232e+00 1.69295263e+01 3.07384655 0.77796272 422.75 -1.49140272e+01 -1.34373960e+00 1.49744397e+01 -3.05173623 0.91986951 423.00 -1.45124494e+01 -2.24388209e+00 1.46848968e+01 -2.98818967 0.92444726 423.25 -1.49997706e+01 -3.23326435e+00 1.53442861e+01 -2.92928679 0.90594224 423.50 -1.53353953e+01 -4.11877650e+00 1.58788749e+01 -2.87920505 0.90348103 423.75 -1.68836118e+01 -4.64213664e+00 1.75101622e+01 -2.87327361 0.89960280 424.00 -1.73394030e+01 -3.95476055e+00 1.77846852e+01 -2.91734914 0.89265590 424.25 -1.81260418e+01 -3.38403889e+00 1.84392275e+01 -2.95702261 0.89169839 424.50 -1.85008971e+01 -2.24367344e+00 1.86364499e+01 -3.02090823 0.81005942 424.75 -2.13676310e+01 2.93090979e+00 2.15677047e+01 3.00527743 0.71631594 425.00 -2.13838150e+01 7.41886222e+00 2.26342011e+01 2.80764810 0.76473496 425.25 -2.06574439e+01 1.14891375e+01 2.36374759e+01 2.63402153 0.85548451 425.50 -1.77926050e+01 1.29256419e+01 2.19920216e+01 2.51332718 0.83538562 425.75 -1.48051824e+01 1.51328991e+01 2.11706887e+01 2.34524845 0.86527850 426.00 -1.14634772e+01 1.41760385e+01 1.82310553e+01 2.25079046 0.87318293 426.25 -9.43863085e+00 1.41491188e+01 1.70083895e+01 2.15908682 0.92591972 426.50 -7.82664216e+00 1.41273675e+01 1.61505059e+01 2.07670973 0.92944524 426.75 -6.60840181e+00 1.41689867e+01 1.56342943e+01 2.00720370 0.95215451 427.00 -4.71468112e+00 1.27116449e+01 1.35578071e+01 1.92596294 0.92064893 427.25 -3.70045691e+00 1.09341609e+01 1.15433641e+01 1.89712757 0.94745973 427.50 -2.93366407e+00 1.01697725e+01 1.05844536e+01 1.85164094 0.95212393 427.75 -2.03200602e+00 9.41772259e+00 9.63444587e+00 1.78330267 0.95209741 428.00 -1.70814402e+00 8.23915581e+00 8.41435942e+00 1.77522060 0.92623307 428.25 -1.14276615e+00 7.45192584e+00 7.53903928e+00 1.72296268 0.93424213 428.50 -6.62913783e-01 6.71945250e+00 6.75207350e+00 1.66913403 0.91862247 428.75 -5.32371575e-01 5.95339296e+00 5.97714875e+00 1.65998233 0.90610382 429.00 -5.16735448e-01 4.51646922e+00 4.54593332e+00 1.68471237 0.77976897 429.25 -1.06145390e+00 3.68043226e+00 3.83043940e+00 1.85158156 0.73624610 429.50 -1.90537013e+00 4.29560248e+00 4.69921653e+00 1.98828433 0.74656099 429.75 -1.89353267e+00 4.89439704e+00 5.24791276e+00 1.93993937 0.83168478 430.00 -1.53955503e+00 3.93896949e+00 4.22915007e+00 1.94339191 0.86828023 430.25 -1.29567454e+00 3.48038996e+00 3.71374296e+00 1.92717894 0.90753801 430.50 -1.22056812e+00 2.90390252e+00 3.14998990e+00 1.96869625 0.88091307 430.75 -1.27778305e+00 2.50944974e+00 2.81603756e+00 2.04176772 0.88017179 431.00 -1.70316203e+00 1.73426752e+00 2.43072926e+00 2.34714568 0.81706601 431.25 -2.02516690e+00 1.30801717e+00 2.41085252e+00 2.56811837 0.86574271 431.50 -2.81238288e+00 1.25503070e+00 3.07970770e+00 2.72186017 0.87125178 431.75 -3.34895687e+00 1.49935201e+00 3.66927357e+00 2.72064708 0.90745524 432.00 -3.69636116e+00 2.30861739e+00 4.35807298e+00 2.58330629 0.92671891 432.25 -3.70053240e+00 2.76528462e+00 4.61960378e+00 2.49984316 0.94295094 432.50 -2.97455918e+00 3.15974039e+00 4.33958081e+00 2.32601582 0.94491538 432.75 -2.49040884e+00 3.11787149e+00 3.99039583e+00 2.24477637 0.94514735 433.00 -1.65688742e+00 2.96513290e+00 3.39665851e+00 2.08036325 0.92568903 433.25 -1.51904246e+00 2.64292709e+00 3.04836900e+00 2.09244843 0.91642787 433.50 -1.56176271e+00 2.09882814e+00 2.61613882e+00 2.21051830 0.92287776 433.75 -1.47390087e+00 1.84622995e+00 2.36240318e+00 2.24451819 0.89208611 434.00 -1.46719133e+00 1.32992811e+00 1.98024220e+00 2.40522822 0.82969760 434.25 -1.40489933e+00 1.07404025e+00 1.76841866e+00 2.48887832 0.73275263 434.50 -1.47904317e+00 7.87636497e-01 1.67569089e+00 2.65226011 0.78830374 434.75 -1.72360463e+00 6.47343093e-01 1.84115888e+00 2.78231783 0.77246506 435.00 -2.03672281e+00 7.31852386e-01 2.16421989e+00 2.79663173 0.74879887 435.25 -1.98225667e+00 9.71554888e-01 2.20754624e+00 2.68587566 0.75504271 435.50 -1.74865930e+00 1.19195493e+00 2.11626225e+00 2.54329587 0.72776153 435.75 -1.49931902e+00 1.24861983e+00 1.95115581e+00 2.44717435 0.66519349 436.00 -9.46707411e-01 1.19240813e+00 1.52252818e+00 2.24183476 0.62753560 436.25 -5.83550264e-01 9.39116119e-01 1.10565365e+00 2.12679002 0.41385591 436.50 -4.04350889e-01 6.27475480e-01 7.46475130e-01 2.14323114 0.32956243 436.75 -2.00229126e-01 2.60997390e-01 3.28954922e-01 2.22519540 0.06597629 437.00 1.10340016e-01 -4.46337136e-01 4.59773594e-01 -1.32844313 0.13484186 437.25 1.67699511e-01 -1.15145769e+00 1.16360558e+00 -1.42617211 0.45189869 437.50 1.94798823e-01 -1.88525964e+00 1.89529694e+00 -1.46783440 0.73203439 437.75 2.46351436e-02 -2.44572633e+00 2.44585040e+00 -1.56072394 0.77504375 438.00 -2.93800055e-01 -3.07106566e+00 3.08508715e+00 -1.66617320 0.86756344 438.25 -2.56120779e-01 -3.52380490e+00 3.53310045e+00 -1.64335176 0.84627193 438.50 -3.78716414e-01 -3.98546641e+00 4.00341962e+00 -1.66553622 0.87650681 438.75 -8.16581911e-01 -4.06650413e+00 4.14768151e+00 -1.76896759 0.83933441 439.00 -9.26874143e-01 -4.60003306e+00 4.69248334e+00 -1.76962698 0.86340849 439.25 -6.32952357e-01 -5.27693707e+00 5.31476185e+00 -1.69017293 0.84644913 439.50 -7.25546647e-01 -5.74903085e+00 5.79463318e+00 -1.69633593 0.86379839 439.75 -7.84724932e-01 -5.90704634e+00 5.95894199e+00 -1.70286858 0.79515284 440.00 -9.25917679e-01 -6.59207947e+00 6.65678866e+00 -1.71034253 0.82734871 440.25 -4.01372553e-01 -7.33545756e+00 7.34643026e+00 -1.62545859 0.80709715 440.50 1.70673355e-01 -8.19283747e+00 8.19461501e+00 -1.54996732 0.83469599 440.75 1.46859955e+00 -7.37443153e+00 7.51924364e+00 -1.37422062 0.64944600 441.00 3.87929195e+00 -7.12257292e+00 8.11048402e+00 -1.07207176 0.55933179 441.25 4.83364226e+00 -4.63436498e+00 6.69637486e+00 -0.76435383 0.23047040 441.50 2.17698242e+00 -5.26940152e+00 5.70138973e+00 -1.17901687 0.12386439 441.75 8.60588259e-01 -1.08027750e+01 1.08369996e+01 -1.49130058 0.44910564 442.00 1.80093606e+00 -1.15625786e+01 1.17019910e+01 -1.41628226 0.54061348 442.25 3.76691297e+00 -1.05419777e+01 1.11947723e+01 -1.22761079 0.62610022 442.50 4.41897180e+00 -9.55065923e+00 1.05234217e+01 -1.13744161 0.66721444 442.75 3.77614362e+00 -9.58008931e+00 1.02974449e+01 -1.19532952 0.75642539 443.00 3.09211059e+00 -8.65152318e+00 9.18749157e+00 -1.22753859 0.76309898 443.25 7.44696491e-01 -4.78724069e+00 4.84481644e+00 -1.41647457 0.67697770 443.50 1.69587541e+00 -3.59415364e+00 3.97415825e+00 -1.12992716 0.74579277 443.75 2.25425022e+00 -2.63260091e+00 3.46586664e+00 -0.86266621 0.82088326 444.00 2.29461319e+00 -1.93742977e+00 3.00314565e+00 -0.70119795 0.79554323 444.25 2.09892338e+00 -1.01899086e+00 2.33319989e+00 -0.45196641 0.77951394 444.50 1.82462043e+00 -7.47838950e-01 1.97192870e+00 -0.38897738 0.77059870 444.75 1.17084423e+00 -4.43262496e-01 1.25194163e+00 -0.36190880 0.60059642 445.00 8.44563451e-01 -1.52199119e-01 8.58167813e-01 -0.17829673 0.38828006 445.25 7.29103687e-01 3.51611264e-01 8.09458256e-01 0.44934817 0.38948664 445.50 6.37040456e-01 5.92033280e-01 8.69668872e-01 0.74879574 0.32845837 445.75 3.39243836e-01 1.07679038e+00 1.12896585e+00 1.26558915 0.42673268 446.00 3.18759653e-01 1.51181571e+00 1.54505484e+00 1.36299441 0.60101229 446.25 5.74203136e-01 1.94914542e+00 2.03196386e+00 1.28430812 0.84017779 446.50 6.85498019e-01 2.17472736e+00 2.28020759e+00 1.26544355 0.83350696 446.75 9.02245410e-01 2.36854401e+00 2.53457048e+00 1.20683841 0.81275702 447.00 1.28529837e+00 2.64905266e+00 2.94439670e+00 1.11906538 0.80145365 447.25 1.47770930e+00 2.65418205e+00 3.03781288e+00 1.06278743 0.86043523 447.50 1.82053544e+00 2.40079389e+00 3.01299860e+00 0.92200079 0.83383529 447.75 2.19271398e+00 2.23266631e+00 3.12934393e+00 0.79442592 0.91299168 448.00 2.36964688e+00 1.92201777e+00 3.05112744e+00 0.68147197 0.86373421 448.25 2.27094828e+00 1.75073994e+00 2.86745470e+00 0.65676168 0.87485523 448.50 2.20945764e+00 1.55955994e+00 2.70442790e+00 0.61464566 0.87432143 448.75 2.36958050e+00 1.33044770e+00 2.71753617e+00 0.51160647 0.86932453 449.00 2.36316604e+00 1.15201209e+00 2.62900847e+00 0.45358697 0.75992310 449.25 2.26020805e+00 1.16608978e+00 2.54328642e+00 0.47630348 0.71551278 449.50 2.11949179e+00 8.63419393e-01 2.28861061e+00 0.38684445 0.56611684 449.75 2.26460839e+00 5.73692050e-01 2.33614506e+00 0.24810982 0.56419443 450.00 2.18192325e+00 3.30466174e-01 2.20680696e+00 0.15031396 0.50359509 450.25 2.14902916e+00 1.41452858e-01 2.15367947e+00 0.06572694 0.55993848 450.50 1.82741717e+00 -7.55901353e-02 1.82897988e+00 -0.04134090 0.60521114 450.75 1.69142182e+00 -3.11916235e-01 1.71994172e+00 -0.18236188 0.62964587 451.00 1.63477580e+00 -3.12112134e-01 1.66430342e+00 -0.18865018 0.65939168 451.25 1.59192944e+00 -2.79160011e-01 1.61622080e+00 -0.17359450 0.70315703 451.50 1.44552697e+00 -2.96933299e-01 1.47570919e+00 -0.20259708 0.62376904 451.75 1.57971694e+00 -8.08425868e-02 1.58178416e+00 -0.05113076 0.67742042 452.00 1.62127354e+00 -3.25531874e-01 1.65363203e+00 -0.19815290 0.71671068 452.25 1.59102216e+00 -3.27777207e-01 1.62443510e+00 -0.20317414 0.75366804 452.50 1.64895415e+00 -3.38479454e-01 1.68333541e+00 -0.20245690 0.72978951 452.75 1.76023546e+00 -4.92650425e-01 1.82787672e+00 -0.27289517 0.71794236 453.00 1.58808675e+00 -4.00817487e-01 1.63788711e+00 -0.24722697 0.79710116 453.25 1.57880402e+00 -2.16660293e-01 1.59360089e+00 -0.13637880 0.81031863 453.50 1.75814727e+00 -1.69316435e-01 1.76628137e+00 -0.09600782 0.77604354 453.75 1.91821716e+00 -2.98187104e-01 1.94125542e+00 -0.15421584 0.75789136 454.00 2.15505435e+00 -3.32139707e-01 2.18049904e+00 -0.15291807 0.78487522 454.25 2.18236421e+00 -3.78628003e-01 2.21496562e+00 -0.17178445 0.79121895 454.50 2.51192525e+00 -4.81850284e-01 2.55772324e+00 -0.18952285 0.87231621 454.75 2.67898071e+00 -5.52867025e-01 2.73543407e+00 -0.20351506 0.84654427 455.00 3.49263822e+00 -9.83655340e-01 3.62851203e+00 -0.27452583 0.81420102 455.25 3.38840892e+00 -1.75325424e+00 3.81512980e+00 -0.47749181 0.80148702 455.50 3.00321480e+00 -2.64862542e+00 4.00431215e+00 -0.72274154 0.80085217 455.75 2.70818027e+00 -2.95191199e+00 4.00599860e+00 -0.82843302 0.79399838 456.00 1.40948044e+00 -3.84457699e+00 4.09480248e+00 -1.21939688 0.79212556 456.25 5.46369060e-01 -3.90876570e+00 3.94676683e+00 -1.43191571 0.81542224 456.50 2.44467102e-01 -3.64271374e+00 3.65090777e+00 -1.50378555 0.88891285 456.75 -2.55851545e-01 -3.26561978e+00 3.27562705e+00 -1.64898362 0.87815113 457.00 -6.00381894e-01 -2.80745318e+00 2.87093221e+00 -1.78147577 0.92919605 457.25 -5.31971083e-01 -2.68228050e+00 2.73452408e+00 -1.76658359 0.92878385 457.50 -5.20750330e-01 -2.55845473e+00 2.61091393e+00 -1.77159432 0.93031154 457.75 -6.42755618e-01 -2.33082017e+00 2.41782080e+00 -1.83987241 0.92906822 458.00 -6.61065525e-01 -2.12612138e+00 2.22652190e+00 -1.87224621 0.94850297 458.25 -6.40608477e-01 -1.91549070e+00 2.01977322e+00 -1.89353868 0.93306310 458.50 -7.03797698e-01 -1.82620950e+00 1.95713371e+00 -1.93864231 0.95450521 458.75 -7.12253955e-01 -1.76779507e+00 1.90588696e+00 -1.95380474 0.95225089 459.00 -5.98548675e-01 -1.66560024e+00 1.76988267e+00 -1.91578446 0.94990803 459.25 -5.93809535e-01 -1.61205693e+00 1.71794567e+00 -1.92372872 0.93694813 459.50 -6.09747301e-01 -1.60277435e+00 1.71484034e+00 -1.93432113 0.94862105 459.75 -6.65649064e-01 -1.55265525e+00 1.68932738e+00 -1.97581074 0.93277963 460.00 -6.51674871e-01 -1.50395518e+00 1.63907332e+00 -1.97968230 0.94773333 460.25 -6.39717774e-01 -1.50351156e+00 1.63394793e+00 -1.97307554 0.94142216 460.50 -6.70637264e-01 -1.45660035e+00 1.60357068e+00 -2.00227562 0.94206402 460.75 -6.83000110e-01 -1.38637262e+00 1.54548316e+00 -2.02854878 0.91678088 461.00 -6.79887523e-01 -1.35421304e+00 1.51530195e+00 -2.03608546 0.92045309 461.25 -7.07308904e-01 -1.20255164e+00 1.39514025e+00 -2.10247442 0.90213101 461.50 -7.27808961e-01 -1.14151297e+00 1.35379383e+00 -2.13839278 0.92863000 461.75 -7.06980259e-01 -1.06348055e+00 1.27703248e+00 -2.15749142 0.90272563 462.00 -6.65990894e-01 -9.81793465e-01 1.18636515e+00 -2.16683777 0.89796226 462.25 -6.28170589e-01 -8.70009501e-01 1.07308659e+00 -2.19615324 0.90953515 462.50 -5.70290783e-01 -7.88042101e-01 9.72749674e-01 -2.19723915 0.88750856 462.75 -3.45544191e-01 -7.56392466e-01 8.31583039e-01 -1.99931710 0.77746398 463.00 -2.24757470e-01 -7.42699130e-01 7.75962575e-01 -1.86465735 0.74253773 463.25 -1.25465351e-01 -7.98917428e-01 8.08709226e-01 -1.72656825 0.75990024 463.50 -5.17475539e-02 -9.39282404e-01 9.40706779e-01 -1.62583334 0.80135641 463.75 5.71904657e-02 -1.06438098e+00 1.06591633e+00 -1.51711675 0.84994927 464.00 6.67230479e-02 -1.13041242e+00 1.13237988e+00 -1.51183933 0.82979124 464.25 1.55670684e-01 -1.30672975e+00 1.31596960e+00 -1.45222516 0.88114486 464.50 1.22370122e-01 -1.32003282e+00 1.32569269e+00 -1.47835819 0.86967968 464.75 2.08333217e-02 -1.43865149e+00 1.43880233e+00 -1.55631619 0.87728238 465.00 -1.34027193e-01 -1.40522664e+00 1.41160376e+00 -1.66588632 0.82555969 465.25 -2.47702927e-01 -1.23622738e+00 1.26079930e+00 -1.76854767 0.79905712 465.50 -1.90719296e-01 -1.12926710e+00 1.14525894e+00 -1.73810520 0.74087226 465.75 3.98375765e-02 -1.04873869e+00 1.04949506e+00 -1.53282840 0.70345410 466.00 1.80000629e-01 -1.00425293e+00 1.02025692e+00 -1.39344124 0.65599370 466.25 3.06504937e-01 -8.34958010e-01 8.89438112e-01 -1.21897821 0.57663788 466.50 4.38837940e-01 -8.89190571e-01 9.91583889e-01 -1.11234197 0.62488600 466.75 8.22679826e-01 -8.43210511e-01 1.17805181e+00 -0.79772169 0.70607676 467.00 1.14895209e+00 -1.10234553e+00 1.59224890e+00 -0.76469903 0.74823506 467.25 1.53114227e+00 -1.59191088e+00 2.20875008e+00 -0.80485379 0.89755081 467.50 1.56161926e+00 -2.00822509e+00 2.54393843e+00 -0.90985667 0.94809324 467.75 1.56479869e+00 -2.26680494e+00 2.75445087e+00 -0.96660320 0.97803780 468.00 1.57570343e+00 -2.39409134e+00 2.86609746e+00 -0.98870369 0.97083742 468.25 1.48211590e+00 -2.65841403e+00 3.04365449e+00 -1.06219883 0.97051114 468.50 1.53727279e+00 -2.95868891e+00 3.33422370e+00 -1.09160844 0.97071663 468.75 1.58367672e+00 -3.19473196e+00 3.56571792e+00 -1.11058255 0.98424424 469.00 1.52327437e+00 -3.41778386e+00 3.74187270e+00 -1.15153182 0.97983001 469.25 1.43972856e+00 -3.68283909e+00 3.95425367e+00 -1.19813416 0.98368663 469.50 1.43610234e+00 -3.90579018e+00 4.16144048e+00 -1.21845375 0.97973931 469.75 1.37542702e+00 -4.09678680e+00 4.32151149e+00 -1.24688752 0.98653863 470.00 1.50271617e+00 -4.30262353e+00 4.55749110e+00 -1.23478466 0.97980062 470.25 1.63670935e+00 -4.50568015e+00 4.79374291e+00 -1.22236248 0.97794040 470.50 1.66788532e+00 -5.01592794e+00 5.28596013e+00 -1.24977993 0.97471633 470.75 1.74108078e+00 -5.33817410e+00 5.61493233e+00 -1.25551867 0.98300519 471.00 2.19953595e+00 -5.55427679e+00 5.97393916e+00 -1.19373638 0.97495999 471.25 2.62381930e+00 -5.80289854e+00 6.36852096e+00 -1.14615036 0.97140356 471.50 3.29789370e+00 -6.76824122e+00 7.52895690e+00 -1.11739251 0.96011311 471.75 3.59727364e+00 -7.34963813e+00 8.18275982e+00 -1.11562502 0.97142536 472.00 4.34436525e+00 -8.69448433e+00 9.71944274e+00 -1.10741346 0.95579106 472.25 4.56632166e+00 -1.00898145e+01 1.10750011e+01 -1.14580936 0.96000309 472.50 5.30494653e+00 -1.29406801e+01 1.39858378e+01 -1.18174754 0.95464992 472.75 5.56744635e+00 -1.49426158e+01 1.59461038e+01 -1.21414155 0.96085961 473.00 5.28401286e+00 -1.80405825e+01 1.87984948e+01 -1.28586972 0.92674384 473.25 6.00647632e+00 -2.05450571e+01 2.14050725e+01 -1.28636679 0.90629600 473.50 5.78059756e+00 -2.64753313e+01 2.70990493e+01 -1.35583088 0.84481632 473.75 5.22545351e+00 -2.96237668e+01 3.00811057e+01 -1.39619844 0.80844386 474.00 7.15579835e+00 -3.66306201e+01 3.73230194e+01 -1.37787572 0.59927112 474.25 9.54236266e+00 -3.61449631e+01 3.73833525e+01 -1.31268282 0.42679966 474.50 3.76638063e+00 -2.13155670e+01 2.16457621e+01 -1.39590530 0.07475319 474.75 1.17069475e+01 4.12002207e+00 1.24107696e+01 0.33839286 0.02291402 475.00 1.76099572e+01 3.49739780e+01 3.91572437e+01 1.10433988 0.47655149 475.25 1.29065034e+01 3.00345961e+01 3.26902859e+01 1.16493357 0.56081244 475.50 1.23613481e+01 2.09097269e+01 2.42903192e+01 1.03688964 0.58290644 475.75 1.10389173e+01 1.72643109e+01 2.04918063e+01 1.00190410 0.66602325 476.00 6.89244756e+00 1.49652303e+01 1.64761632e+01 1.13919212 0.77375560 476.25 5.49364363e+00 1.30934474e+01 1.41992424e+01 1.17353223 0.79708217 476.50 3.48655675e+00 1.07200044e+01 1.12727358e+01 1.25634885 0.79317784 476.75 2.01011638e+00 9.95274768e+00 1.01537064e+01 1.37151112 0.78585355 477.00 8.34064684e-01 1.02367823e+01 1.02707047e+01 1.48949868 0.87686988 477.25 7.48274707e-01 1.02964774e+01 1.03236312e+01 1.49825098 0.88733655 477.50 1.69656990e+00 1.04381303e+01 1.05751082e+01 1.40966954 0.92122309 477.75 1.71326638e+00 9.49823898e+00 9.65151933e+00 1.39233799 0.89635982 478.00 1.77933038e+00 8.88847390e+00 9.06482128e+00 1.37322384 0.91677425 478.25 1.58483536e+00 8.18320443e+00 8.33525872e+00 1.37949534 0.89775606 478.50 1.07578631e+00 8.05407271e+00 8.12560172e+00 1.43801180 0.91976042 478.75 9.14561617e-01 8.39888488e+00 8.44853184e+00 1.46233283 0.88534558 479.00 4.92668988e-01 8.84284601e+00 8.85655962e+00 1.51514002 0.93150242 479.25 1.04072424e+00 9.63754916e+00 9.69357833e+00 1.46322676 0.89969919 479.50 2.15583660e+00 1.07520777e+01 1.09660753e+01 1.37291602 0.95290203 479.75 3.41070891e+00 1.07369224e+01 1.12656308e+01 1.26321593 0.93853635 480.00 4.93693105e+00 1.01906076e+01 1.13235053e+01 1.11965868 0.95026751 480.25 6.31462713e+00 9.58410070e+00 1.14773473e+01 0.98821444 0.94858448 480.50 7.20299210e+00 9.11399518e+00 1.16167122e+01 0.90198444 0.94061437 480.75 8.51434356e+00 7.23574715e+00 1.11736334e+01 0.70439554 0.90839016 481.00 9.46223843e+00 5.93724878e+00 1.11707152e+01 0.56037186 0.90549907 481.25 1.02453307e+01 3.69751775e+00 1.08921273e+01 0.34635019 0.87476364 481.50 1.06343492e+01 1.74963183e+00 1.07773185e+01 0.16306559 0.88015610 481.75 8.33484585e+00 -1.12004677e+00 8.40976575e+00 -0.13358098 0.77189225 482.00 6.44965948e+00 -2.44725910e+00 6.89834651e+00 -0.36265762 0.76233023 482.25 4.68974868e+00 -1.21669463e+00 4.84500655e+00 -0.25384070 0.76776271 482.50 4.29720669e+00 -7.39428970e-01 4.36036014e+00 -0.17040327 0.78743489 482.75 5.26659260e+00 -2.08634089e-01 5.27072346e+00 -0.03959392 0.78960854 483.00 6.46057348e+00 -1.33382066e+00 6.59682403e+00 -0.20359496 0.83836834 483.25 5.85653596e+00 -3.90124803e+00 7.03695599e+00 -0.58763496 0.85862198 483.50 4.67799834e+00 -4.55188599e+00 6.52712299e+00 -0.77173553 0.86716001 483.75 3.39489900e+00 -5.18779804e+00 6.19988610e+00 -0.99133364 0.86222660 484.00 2.27077996e+00 -5.69771678e+00 6.13354858e+00 -1.19154740 0.84648658 484.25 -1.08065197e+00 -5.19171838e+00 5.30299429e+00 -1.77601522 0.76033308 484.50 -2.60007223e+00 -3.86538747e+00 4.65849717e+00 -2.16293325 0.77139078 484.75 -2.68291639e+00 -2.38217472e+00 3.58786799e+00 -2.41550024 0.84457970 485.00 -2.45598330e+00 -2.05158664e+00 3.20013464e+00 -2.44566995 0.84085870 485.25 -2.56667439e+00 -1.93956336e+00 3.21709861e+00 -2.49447149 0.78955865 485.50 -3.09841950e+00 -1.57626135e+00 3.47632036e+00 -2.67098485 0.77815374 485.75 -4.39056970e+00 -2.44833492e-01 4.39739078e+00 -3.08588686 0.74515566 486.00 -4.57530956e+00 1.62210915e+00 4.85434812e+00 2.80088313 0.72925462 486.25 -3.15979250e+00 3.93852344e+00 5.04938170e+00 2.24692503 0.81742784 486.50 -1.65846600e+00 4.00214690e+00 4.33216912e+00 1.96364948 0.73981219 486.75 6.95227584e-01 3.62633516e+00 3.69237703e+00 1.38137840 0.80973910 487.00 1.22806076e+00 2.80151963e+00 3.05886343e+00 1.15766828 0.76962228 487.25 1.97251141e+00 1.52923556e+00 2.49586911e+00 0.65948083 0.79626503 487.50 1.72592607e+00 1.03429431e+00 2.01210972e+00 0.53988196 0.79100382 487.75 1.44380320e+00 5.34689507e-01 1.53963000e+00 0.35467373 0.75547689 488.00 1.16665086e+00 2.61113184e-01 1.19551425e+00 0.22018562 0.66152822 488.25 6.59400286e-01 2.30830815e-01 6.98635529e-01 0.33672983 0.44859148 488.50 4.54122728e-01 3.12046291e-01 5.50999401e-01 0.60204345 0.35121148 488.75 3.62423289e-01 3.49006206e-01 5.03146075e-01 0.76654107 0.37170179 489.00 3.31708992e-01 4.51882299e-01 5.60560851e-01 0.93757472 0.45126259 489.25 2.77143046e-01 5.02332412e-01 5.73712576e-01 1.06663932 0.55839460 489.50 2.30706324e-01 5.60578432e-01 6.06195996e-01 1.18037247 0.59771565 489.75 2.48470573e-01 6.92668553e-01 7.35885419e-01 1.22637882 0.71826478 490.00 3.63557872e-01 9.25700052e-01 9.94532509e-01 1.19656566 0.80669364 490.25 4.49789725e-01 1.05942462e+00 1.15095235e+00 1.16929809 0.88782335 490.50 5.97757119e-01 1.13975509e+00 1.28699465e+00 1.08777194 0.88935536 490.75 7.77323152e-01 1.15457447e+00 1.39185972e+00 0.97824636 0.91597778 491.00 9.55610720e-01 1.10340468e+00 1.45968960e+00 0.85705422 0.92909951 491.25 1.11537372e+00 1.06226166e+00 1.54027867e+00 0.76101321 0.91904950 491.50 1.31591797e+00 9.35631973e-01 1.61463535e+00 0.61807764 0.93073534 491.75 1.43517270e+00 9.17822671e-01 1.70356072e+00 0.56897310 0.95380278 492.00 1.50748963e+00 7.59941947e-01 1.68820518e+00 0.46693092 0.93973057 492.25 1.57417135e+00 6.61483511e-01 1.70750575e+00 0.39780701 0.94765315 492.50 1.58552261e+00 5.35864642e-01 1.67362865e+00 0.32592088 0.94554862 492.75 1.63603345e+00 4.60102347e-01 1.69949982e+00 0.27414929 0.95926369 493.00 1.82123202e+00 2.96341664e-01 1.84518413e+00 0.16130131 0.96023674 493.25 1.87095735e+00 2.00402125e-01 1.88165949e+00 0.10670524 0.96912727 493.50 1.91736604e+00 -2.19084220e-02 1.91749120e+00 -0.01142581 0.96084005 493.75 1.94720655e+00 -1.59331061e-01 1.95371434e+00 -0.08164357 0.96252804 494.00 1.94123425e+00 -3.57756934e-01 1.97392514e+00 -0.18224860 0.95641658 494.25 1.93518999e+00 -5.20913152e-01 2.00407356e+00 -0.26294677 0.95434725 494.50 1.88702026e+00 -7.33344485e-01 2.02450972e+00 -0.37066261 0.94833945 494.75 1.87305916e+00 -9.00267192e-01 2.07817988e+00 -0.44804002 0.95031988 495.00 1.64791535e+00 -1.19527087e+00 2.03575476e+00 -0.62751986 0.95553594 495.25 1.55762984e+00 -1.33126837e+00 2.04902079e+00 -0.70720229 0.95186940 495.50 1.36338943e+00 -1.56439818e+00 2.07513190e+00 -0.85394610 0.95231171 495.75 1.18422823e+00 -1.61519039e+00 2.00280715e+00 -0.93814603 0.94104129 496.00 9.36591207e-01 -1.70826808e+00 1.94817426e+00 -1.06928272 0.92163826 496.25 6.81947986e-01 -1.70436265e+00 1.83573013e+00 -1.19018731 0.90031037 496.50 2.95468367e-01 -1.66384218e+00 1.68987347e+00 -1.39504652 0.88685795 496.75 2.46998585e-01 -1.40356931e+00 1.42513687e+00 -1.39660100 0.83017795 497.00 3.49967182e-01 -1.33681083e+00 1.38186115e+00 -1.31474991 0.81030786 497.25 4.78927003e-01 -1.36200580e+00 1.44375582e+00 -1.23266693 0.79352341 497.50 3.07399763e-01 -1.45474732e+00 1.48687066e+00 -1.36255170 0.79255357 497.75 8.79726515e-02 -1.59678615e+00 1.59920768e+00 -1.51575840 0.81065606 498.00 -1.93632232e-01 -1.71493111e+00 1.72582796e+00 -1.68322978 0.88056493 498.25 -4.38588170e-01 -1.68690109e+00 1.74298447e+00 -1.82516099 0.89418641 498.50 -5.75293031e-01 -1.41883845e+00 1.53103384e+00 -1.95600725 0.90315136 498.75 -5.99533962e-01 -1.37747723e+00 1.50229307e+00 -1.98130875 0.88276822 499.00 -7.62062139e-01 -1.44683092e+00 1.63525484e+00 -2.05558389 0.82879511 499.25 -1.20949706e+00 -1.37102744e+00 1.82827770e+00 -2.29368011 0.85447208 499.50 -1.44334013e+00 -1.15245079e+00 1.84699041e+00 -2.46779084 0.90497239 499.75 -1.57210459e+00 -9.59942671e-01 1.84201052e+00 -2.59340824 0.86947370 500.00 -1.66370008e+00 -4.47294134e-01 1.72277973e+00 -2.87894830 0.82571865 500.25 -1.57870837e+00 -6.13913102e-03 1.57872031e+00 -3.13770397 0.74984069 500.50 -1.68372758e+00 3.81582941e-01 1.72642524e+00 2.91872743 0.80764162 500.75 -1.48788191e+00 7.92591441e-01 1.68582139e+00 2.65213024 0.82245502 501.00 -1.32733109e+00 1.05077184e+00 1.69290557e+00 2.47196850 0.87254161 501.25 -9.62253722e-01 1.23795399e+00 1.56794844e+00 2.23153775 0.76428727 501.50 -6.37489236e-01 1.56132917e+00 1.68645821e+00 1.95843653 0.82947775 501.75 -5.72506768e-01 1.50750645e+00 1.61255688e+00 1.93374295 0.83772690 502.00 -3.34091089e-01 1.45956015e+00 1.49730849e+00 1.79581828 0.81076977 502.25 -3.05178342e-02 1.30450756e+00 1.30486448e+00 1.59418620 0.75864635 502.50 1.80382617e-01 1.18826744e+00 1.20188078e+00 1.42014348 0.72706674 502.75 4.29280879e-01 9.92107591e-01 1.08099933e+00 1.16242529 0.80338352 503.00 4.34148077e-01 9.27631791e-01 1.02419983e+00 1.13306033 0.85047306 503.25 2.97898103e-01 7.54437419e-01 8.11122123e-01 1.19472774 0.63253598 503.50 1.84542658e-01 7.22837411e-01 7.46022731e-01 1.32083274 0.59110677 503.75 -1.21516654e-01 7.88194057e-01 7.97506218e-01 1.72376296 0.63791539 504.00 -1.20795527e-01 9.43259945e-01 9.50963135e-01 1.69816483 0.68764460 504.25 -1.07736773e-01 1.08469633e+00 1.09003364e+00 1.66979599 0.74065216 504.50 -1.22380162e-01 1.15906491e+00 1.16550777e+00 1.67599182 0.80164046 504.75 -3.07563677e-01 1.37142553e+00 1.40549045e+00 1.79141172 0.88145826 505.00 -2.77384134e-01 1.45820119e+00 1.48434924e+00 1.75877398 0.88598552 505.25 -2.66995003e-01 1.56918022e+00 1.59173267e+00 1.73933164 0.83666408 505.50 -3.83953882e-01 1.60364775e+00 1.64897140e+00 1.80579786 0.83664845 505.75 -6.29160394e-01 1.88111257e+00 1.98353908e+00 1.89356220 0.90270982 506.00 -8.04592617e-01 1.97673278e+00 2.13420753e+00 1.95734965 0.90763138 506.25 -1.21515628e+00 2.24067541e+00 2.54896667e+00 2.06772172 0.88978215 506.50 -1.55780891e+00 2.58015171e+00 3.01395943e+00 2.11398064 0.88786672 506.75 -2.08413175e+00 3.45823685e+00 4.03769826e+00 2.11316745 0.87727116 507.00 -2.39359521e+00 4.18111154e+00 4.81777871e+00 2.09073334 0.89313974 507.25 -2.47183992e+00 5.52235600e+00 6.05032300e+00 1.99165765 0.93683846 507.50 -2.40912293e+00 6.02082188e+00 6.48491861e+00 1.95141641 0.93122059 507.75 -2.58278384e+00 7.05736484e+00 7.51512946e+00 1.92162688 0.92586463 508.00 -2.92780435e+00 7.65216068e+00 8.19314356e+00 1.93622330 0.88580004 508.25 -3.26481168e+00 9.27286687e+00 9.83082170e+00 1.90932494 0.89738370 508.50 -3.85395733e+00 1.02569578e+01 1.09571059e+01 1.93021629 0.83336322 508.75 -4.50380802e+00 1.18446961e+01 1.26720603e+01 1.93415162 0.80864132 509.00 -5.36676897e+00 1.23813047e+01 1.34944031e+01 1.97980866 0.65201803 509.25 -7.57027693e+00 1.29419960e+01 1.49934770e+01 2.10006788 0.51023782 509.50 -7.41278010e+00 9.56465733e+00 1.21009082e+01 2.23011754 0.29676405 509.75 -8.20676244e+00 2.26862941e-01 8.20989748e+00 3.11395628 0.07949956 510.00 -1.53965311e+00 -1.17281319e+01 1.18287620e+01 -1.70132851 0.19552219 510.25 5.76429507e+00 -2.00108253e+01 2.08245102e+01 -1.29033041 0.63508146 510.50 7.94192814e+00 -1.86902865e+01 2.03076594e+01 -1.16899110 0.74373922 510.75 8.96932529e+00 -1.85217887e+01 2.05792481e+01 -1.11982140 0.74543531 511.00 8.32105197e+00 -1.59137371e+01 1.79579212e+01 -1.08900890 0.74728383 511.25 8.30826700e+00 -1.46173273e+01 1.68134933e+01 -1.05394774 0.78012250 511.50 8.44307581e+00 -1.28873053e+01 1.54067572e+01 -0.99081153 0.84558115 511.75 8.29005141e+00 -1.20244445e+01 1.46052120e+01 -0.96719743 0.87237109 512.00 8.07282039e+00 -1.01831303e+01 1.29948671e+01 -0.90048310 0.84222851 512.25 7.82825819e+00 -9.80227142e+00 1.25445666e+01 -0.89689940 0.84869452 512.50 8.02279553e+00 -8.87001170e+00 1.19600316e+01 -0.83550866 0.82284896 512.75 8.54088222e+00 -8.62630995e+00 1.21391883e+01 -0.79037434 0.83133367 513.00 9.26796104e+00 -8.56815051e+00 1.26217394e+01 -0.74618268 0.86813463 513.25 9.06577080e+00 -9.18465767e+00 1.29052755e+01 -0.79191227 0.88680143 513.50 9.65326376e+00 -9.02913887e+00 1.32178232e+01 -0.75200348 0.86279747 513.75 1.10628212e+01 -9.00456578e+00 1.42642286e+01 -0.68318839 0.90272718 514.00 1.16894401e+01 -8.56385865e+00 1.44907793e+01 -0.63228152 0.87732900 514.25 1.26955444e+01 -8.58581540e+00 1.53262218e+01 -0.59463242 0.87076939 514.50 1.43573318e+01 -1.01587480e+01 1.75878690e+01 -0.61578524 0.80627817 514.75 1.51600083e+01 -1.01763878e+01 1.82588258e+01 -0.59117953 0.74834092 515.00 1.94217221e+01 -9.86843562e+00 2.17850708e+01 -0.47011718 0.68421496 515.25 2.07234085e+01 -7.78947286e+00 2.21390051e+01 -0.35954018 0.57075788 515.50 1.29464838e+01 -9.54414972e+00 1.60842232e+01 -0.63525875 0.19808303 515.75 4.31803828e+00 -1.30027249e+01 1.37009601e+01 -1.25016773 0.10461305 516.00 -1.53951057e+01 -2.35352047e+01 2.81232135e+01 -2.15007007 0.34139462 516.25 -1.90620264e+01 -1.72634869e+01 2.57174810e+01 -2.40566584 0.34005131 516.50 -2.73909271e+01 -4.33978604e+00 2.77325915e+01 -2.98445998 0.51557151 516.75 -2.44710850e+01 -7.07604575e-01 2.44813134e+01 -3.11268476 0.52546065 517.00 -1.81442138e+01 5.18068924e+00 1.88693412e+01 2.86346481 0.63412163 517.25 -1.35228176e+01 6.16770556e+00 1.48629468e+01 2.71368072 0.69893478 517.50 -8.65161508e+00 4.35141093e+00 9.68427698e+00 2.67558035 0.69239035 517.75 -6.35820302e+00 2.25334399e+00 6.74568786e+00 2.80100384 0.61026131 518.00 -4.68086390e+00 1.89441412e-01 4.68469582e+00 3.10114327 0.55518696 518.25 -3.38503837e+00 -2.06385071e+00 3.96458882e+00 -2.59407286 0.55741507 518.50 -3.47200932e+00 -3.08641655e+00 4.64551567e+00 -2.41492038 0.86684941 518.75 -3.76459853e+00 -3.86394412e+00 5.39465163e+00 -2.34317235 0.87666803 519.00 -4.06606384e+00 -4.67059760e+00 6.19252429e+00 -2.28710955 0.91320506 519.25 -4.09264892e+00 -4.63549967e+00 6.18365849e+00 -2.29407909 0.89837875 519.50 -4.49758808e+00 -4.38345147e+00 6.28036188e+00 -2.36904550 0.90924858 519.75 -5.44789224e+00 -4.23108108e+00 6.89794005e+00 -2.48125536 0.88543225 520.00 -6.48423783e+00 -3.72676766e+00 7.47891286e+00 -2.61995184 0.89028664 520.25 -6.80789156e+00 -2.36907597e+00 7.20832216e+00 -2.80670989 0.77627060 520.50 -8.00834919e+00 -4.86084479e-01 8.02308761e+00 -3.08096982 0.79993221 520.75 -7.13478462e+00 4.50443637e+00 8.43771880e+00 2.57845109 0.60474946 521.00 -4.47847888e+00 9.87772369e+00 1.08455612e+01 1.99646729 0.76079850 521.25 8.96359429e-01 1.17255138e+01 1.17597251e+01 1.49449950 0.63024198 521.50 8.88198049e+00 1.42908267e+01 1.68260900e+01 1.01470613 0.65506969 521.75 2.09051288e+01 1.01811801e+01 2.32525448e+01 0.45320841 0.72852001 522.00 2.69513733e+01 3.45124653e+00 2.71714487e+01 0.12736143 0.79124056 522.25 2.95940534e+01 -9.92324358e+00 3.12134388e+01 -0.32353037 0.80021618 522.50 2.63527966e+01 -1.77883143e+01 3.17945595e+01 -0.59375427 0.83758889 522.75 2.20223843e+01 -2.31753057e+01 3.19699891e+01 -0.81090105 0.78058288 523.00 1.98165587e+01 -2.88288011e+01 3.49827925e+01 -0.96858535 0.71507211 523.25 1.81876401e+01 -3.71612449e+01 4.13732809e+01 -1.11564450 0.55150153 523.50 1.09988092e+01 -4.37820773e+01 4.51424866e+01 -1.32467243 0.46822901 523.75 -1.10636924e+01 -3.63435309e+01 3.79902293e+01 -1.86630308 0.21471296 524.00 -4.01107823e+01 1.13855656e-01 4.01109439e+01 3.13875413 0.24029055 524.25 -3.55236056e+01 2.14997553e+01 4.15230784e+01 2.59734049 0.54949222 524.50 -2.58793431e+01 2.60741900e+01 3.67369539e+01 2.35244410 0.61789420 524.75 -1.07514766e+01 3.00480280e+01 3.19136058e+01 1.91441157 0.72942295 525.00 -4.68045835e+00 3.02619913e+01 3.06218028e+01 1.72424507 0.79108245 525.25 3.23943822e+00 2.47483429e+01 2.49594559e+01 1.44064114 0.84921965 525.50 7.24315448e+00 2.37955804e+01 2.48735388e+01 1.27531621 0.87302391 525.75 1.22943080e+01 2.09166442e+01 2.42622343e+01 1.03941332 0.89593614 526.00 1.41384170e+01 1.95228306e+01 2.41046831e+01 0.94401328 0.91155373 526.25 1.95982858e+01 1.79919464e+01 2.66045661e+01 0.74269125 0.89801443 526.50 2.21217603e+01 1.74308141e+01 2.81639052e+01 0.66734932 0.90417665 526.75 2.47813786e+01 2.28699475e+01 3.37216729e+01 0.74530679 0.88239778 527.00 2.62763093e+01 2.75522404e+01 3.80732239e+01 0.80909734 0.89342940 527.25 2.66580826e+01 3.16587505e+01 4.13875567e+01 0.87093890 0.86328868 527.50 2.01956794e+01 3.77792673e+01 4.28385166e+01 1.07987635 0.74566189 527.75 -1.15846037e+01 4.27001502e+01 4.42437100e+01 1.83572059 0.78992498 528.00 -1.90584223e+01 3.58940531e+01 4.06399619e+01 2.05890660 0.81152239 528.25 -2.11366834e+01 2.38834383e+01 3.18932283e+01 2.29525831 0.85557936 528.50 -2.18811167e+01 1.75616529e+01 2.80569942e+01 2.46527201 0.84306020 528.75 -2.00026956e+01 8.37422460e+00 2.16849134e+01 2.74510870 0.88318478 529.00 -1.88848862e+01 4.75854177e+00 1.94751802e+01 2.89475491 0.86742347 529.25 -1.88261033e+01 -1.29193016e+00 1.88703802e+01 -3.07307567 0.86240962 529.50 -2.13355674e+01 -1.12125342e+00 2.13650099e+01 -3.08908770 0.84629629 529.75 -2.23682897e+01 5.62133471e+00 2.30638199e+01 2.89538312 0.84915733 530.00 -1.82993132e+01 6.43405884e+00 1.93974734e+01 2.80349217 0.88204669 530.25 -1.57403981e+01 5.24095179e+00 1.65899882e+01 2.82017649 0.94144972 530.50 -1.47028456e+01 4.16140615e+00 1.52804113e+01 2.86577269 0.93605974 530.75 -1.36167233e+01 3.09843942e+00 1.39647943e+01 2.91785562 0.92405691 531.00 -1.17414303e+01 2.18746535e+00 1.19434580e+01 2.95740116 0.93480241 531.25 -1.11348218e+01 1.52261913e+00 1.12384441e+01 3.00569162 0.94264360 531.50 -1.12507015e+01 1.54542388e+00 1.13563471e+01 3.00508450 0.95293597 531.75 -1.10947901e+01 9.13574195e-01 1.11323396e+01 3.05943537 0.96055338 532.00 -1.07183371e+01 2.22883731e-01 1.07206542e+01 3.12080103 0.93661621 532.25 -1.02750964e+01 -3.30444572e-01 1.02804085e+01 -3.10944398 0.92787960 532.50 -9.93591296e+00 -3.15741756e-01 9.94092849e+00 -3.10982551 0.88892774 532.75 -9.01716886e+00 -5.20105149e-01 9.03215609e+00 -3.08397706 0.86740799 533.00 -8.22924218e+00 -2.21038474e+00 8.52092880e+00 -2.87918499 0.80311089 533.25 -8.57174345e+00 -2.77479871e+00 9.00967778e+00 -2.82852377 0.79510085 533.50 -1.06801263e+01 -4.51957390e+00 1.15970533e+01 -2.74126790 0.83169998 533.75 -1.24059235e+01 -5.87141279e+00 1.37251749e+01 -2.69955275 0.86143614 534.00 -1.45380323e+01 -4.92658977e+00 1.53501033e+01 -2.81486205 0.83166200 534.25 -1.68668173e+01 -3.07620110e+00 1.71450442e+01 -2.96119359 0.87192357 534.50 -1.82747084e+01 4.17440430e-01 1.82794755e+01 3.11875410 0.91984424 534.75 -1.79063724e+01 2.51845022e+00 1.80826094e+01 3.00186370 0.93023361 535.00 -1.60840271e+01 4.45436055e+00 1.66894355e+01 2.87142084 0.89362859 535.25 -1.50877632e+01 5.74938162e+00 1.61460828e+01 2.77751749 0.90931667 535.50 -1.32326740e+01 6.34834979e+00 1.46766892e+01 2.69427746 0.93211728 535.75 -1.26304464e+01 6.21509543e+00 1.40767748e+01 2.68430713 0.91361329 536.00 -1.18340185e+01 8.42232858e+00 1.45251372e+01 2.52305419 0.87344731 536.25 -9.50327068e+00 9.47481333e+00 1.34195470e+01 2.35769397 0.85802075 536.50 -4.61948010e+00 9.77273461e+00 1.08095300e+01 2.01235874 0.77853019 536.75 -3.31046871e+00 9.58887664e+00 1.01442475e+01 1.90322479 0.68566396 537.00 7.88430179e-01 7.97074764e+00 8.00964669e+00 1.47220159 0.46947023 537.25 1.66891472e+00 6.65460348e+00 6.86068683e+00 1.32507332 0.39209770 537.50 -7.03712970e-01 1.55508589e+00 1.70689896e+00 1.99574685 0.02415906 537.75 -4.02555905e+00 -1.15986334e+00 4.18932078e+00 -2.86106584 0.10389661 538.00 -8.02848375e+00 -4.53865563e+00 9.22257807e+00 -2.62706422 0.31692836 538.25 -8.00626889e+00 -6.21228361e+00 1.01337461e+01 -2.48170343 0.33721583 538.50 -1.11090939e+01 -4.67842744e+00 1.20540305e+01 -2.74300031 0.46915885 538.75 -1.29011712e+01 -3.01756095e+00 1.32493733e+01 -2.91182507 0.49454125 539.00 -1.30994619e+01 4.94212727e+00 1.40007330e+01 2.78082710 0.49397360 539.25 -1.12999141e+01 6.68239978e+00 1.31279292e+01 2.60754490 0.39161604 539.50 -1.20678470e+01 1.05698697e+01 1.60422902e+01 2.42226991 0.38532750 539.75 -1.27431625e+01 1.45509416e+01 1.93421325e+01 2.29005777 0.43203942 540.00 -9.56755413e+00 1.53568066e+01 1.80933579e+01 2.12796851 0.51666770 540.25 -6.37347820e+00 1.69295649e+01 1.80895382e+01 1.93085539 0.60995960 540.50 -2.45227770e+00 1.86541406e+01 1.88146387e+01 1.70150703 0.65070025 540.75 2.63860778e+00 1.31151045e+01 1.33779003e+01 1.37225827 0.40109234 541.00 4.81949501e+00 9.07868119e+00 1.02786178e+01 1.08276776 0.33619903 541.25 5.82410266e+00 8.44802477e+00 1.02610572e+01 0.96721718 0.42906383 541.50 2.96479231e+00 6.97630153e+00 7.58015676e+00 1.16894217 0.42617113 541.75 1.20892345e+00 4.58084952e+00 4.73768701e+00 1.31277109 0.24570630 542.00 2.73420941e+00 3.84167533e+00 4.71533355e+00 0.95224571 0.20451075 542.25 1.87347445e+00 3.44578075e+00 3.92215648e+00 1.07280206 0.20140025 542.50 1.25976945e+00 2.34880844e+00 2.66531802e+00 1.07849794 0.15613936 542.75 1.82772761e-01 1.02744538e+00 1.04357553e+00 1.39474745 0.03217063 543.00 -3.64169101e-01 1.19920908e+00 1.25328431e+00 1.86562071 0.05710875 543.25 -3.04435911e+00 1.32824152e+00 3.32149785e+00 2.73019328 0.19921790 543.50 -4.98771856e+00 7.77045095e-01 5.04788426e+00 2.98704333 0.34721295 543.75 -3.49981072e+00 4.39021502e+00 5.61450470e+00 2.24381805 0.32560790 544.00 -2.35494483e+00 7.16649973e+00 7.54350605e+00 1.88828501 0.61151368 544.25 -1.09028915e+00 8.32602839e+00 8.39711136e+00 1.70100493 0.78872217 544.50 -6.99704903e-02 8.81894723e+00 8.81922480e+00 1.57873027 0.85392095 544.75 1.67610606e+00 8.98574383e+00 9.14072884e+00 1.38638611 0.81244570 545.00 2.32666101e+00 9.24974657e+00 9.53788043e+00 1.32437084 0.77582658 545.25 3.90988131e+00 8.00490660e+00 8.90874298e+00 1.11644297 0.75770149 545.50 4.81190210e+00 6.75674775e+00 8.29506130e+00 0.95195419 0.78212917 545.75 5.90617538e+00 6.15604992e+00 8.53111120e+00 0.80611066 0.76518318 546.00 6.40095714e+00 5.71630455e+00 8.58186402e+00 0.72895592 0.73736212 546.25 5.96309525e+00 3.90590232e+00 7.12843446e+00 0.57989093 0.59565073 546.50 5.95838070e+00 3.10005496e+00 6.71659447e+00 0.47974345 0.51801467 546.75 5.62453486e+00 2.60502780e+00 6.19851290e+00 0.43373908 0.50983808 547.00 5.41668527e+00 1.29435490e+00 5.56918611e+00 0.23455856 0.53718942 547.25 3.41118158e+00 -4.85217484e-01 3.44551821e+00 -0.14129537 0.26451079 547.50 2.69320401e+00 -5.31033291e-01 2.74505814e+00 -0.19467803 0.14240856 547.75 2.61005559e+00 4.69117325e-01 2.65187882e+00 0.17783587 0.11486447 548.00 3.20745635e+00 1.72399179e+00 3.64141785e+00 0.49319179 0.20647374 548.25 5.09938928e+00 3.29670421e+00 6.07223432e+00 0.57390378 0.57457860 548.50 5.97144215e+00 3.30057360e+00 6.82289582e+00 0.50493399 0.60351139 548.75 8.50723410e+00 2.44984823e+00 8.85295366e+00 0.28038606 0.65747324 549.00 1.03076657e+01 8.70323465e-02 1.03080331e+01 0.00844326 0.63013867 549.25 1.17044093e+01 -2.91269279e+00 1.20613837e+01 -0.24390008 0.79839110 549.50 1.11874858e+01 -3.86026338e+00 1.18347570e+01 -0.33225994 0.81840236 549.75 1.09532896e+01 -7.29232023e+00 1.31587418e+01 -0.58737833 0.85525550 550.00 8.76433012e+00 -9.89465985e+00 1.32180852e+01 -0.84590252 0.73704671 550.25 7.77666785e+00 -1.41962653e+01 1.61867388e+01 -1.06964625 0.76338102 550.50 7.31740097e+00 -1.42602125e+01 1.60280385e+01 -1.09669675 0.72622434 550.75 6.15319022e+00 -1.33378822e+01 1.46888002e+01 -1.13855887 0.66885029 551.00 5.16588724e+00 -1.33304016e+01 1.42963631e+01 -1.20108878 0.69529121 551.25 2.77774889e+00 -1.47417561e+01 1.50011754e+01 -1.38455275 0.62475970 551.50 7.96687920e-01 -1.43568362e+01 1.43789241e+01 -1.51536130 0.53318614 551.75 -2.57295233e+00 -1.66834717e+01 1.68807083e+01 -1.72381244 0.59582528 552.00 -5.05181680e+00 -1.69021595e+01 1.76409708e+01 -1.86123068 0.62300841 552.25 -1.08849784e+01 -1.64752032e+01 1.97462674e+01 -2.15464882 0.71772939 552.50 -1.67518143e+01 -1.27307417e+01 2.10403200e+01 -2.49174631 0.76204836 552.75 -1.91211229e+01 -1.01088809e+01 2.16288422e+01 -2.65526820 0.86283908 553.00 -1.75223267e+01 -8.62119117e+00 1.95283607e+01 -2.68435602 0.85336510 553.25 -1.78843405e+01 -4.61833663e+00 1.84710224e+01 -2.88887991 0.84833299 553.50 -1.83515913e+01 -2.42774430e+00 1.85114788e+01 -3.01006571 0.88405559 553.75 -1.81440760e+01 -1.46065558e+00 1.82027747e+01 -3.06126272 0.87806672 554.00 -1.59306573e+01 -2.49255956e-01 1.59326071e+01 -3.12594762 0.83870146 554.25 -1.53220050e+01 8.41510493e-01 1.53450962e+01 3.08672608 0.85590702 554.50 -1.34580088e+01 1.73395756e+00 1.35692524e+01 3.01345651 0.84896814 554.75 -1.15406755e+01 2.99175862e+00 1.19221563e+01 2.88794035 0.88034518 555.00 -1.02244196e+01 4.11946428e+00 1.10231004e+01 2.75858494 0.91340697 555.25 -9.43153251e+00 3.80271806e+00 1.01692905e+01 2.75833762 0.84937673 555.50 -7.61420508e+00 3.23404510e+00 8.27255503e+00 2.73994363 0.73271824 555.75 -7.11248841e+00 3.59616304e+00 7.96993601e+00 2.67346513 0.75167096 556.00 -7.35406271e+00 2.85402194e+00 7.88845229e+00 2.77139741 0.85301794 556.25 -7.38056323e+00 3.15644137e+00 8.02719352e+00 2.73746314 0.90326549 556.50 -7.47741639e+00 3.51533014e+00 8.26252394e+00 2.70212832 0.90498938 556.75 -8.24067246e+00 3.86410385e+00 9.10164717e+00 2.70312790 0.89390193 557.00 -7.03441380e+00 4.78909067e+00 8.50989818e+00 2.54386315 0.91007333 557.25 -6.26520391e+00 5.30997495e+00 8.21271052e+00 2.43853182 0.91959052 557.50 -4.88528579e+00 5.32720042e+00 7.22807593e+00 2.31294948 0.88300762 557.75 -4.43444002e+00 5.48704572e+00 7.05492232e+00 2.25049633 0.84678892 558.00 -3.60392384e+00 5.03113529e+00 6.18874700e+00 2.19239430 0.80114836 558.25 -3.39602962e+00 4.34208833e+00 5.51241764e+00 2.23453870 0.76113692 558.50 -3.02477602e+00 3.05461641e+00 4.29883139e+00 2.35128608 0.75638021 558.75 -3.16774420e+00 2.77783523e+00 4.21319022e+00 2.42168036 0.80440173 559.00 -3.29357254e+00 2.96429585e+00 4.43110256e+00 2.40876404 0.76911483 559.25 -3.22249647e+00 2.80803688e+00 4.27428996e+00 2.42481344 0.73843219 559.50 -3.42854327e+00 2.08325685e+00 4.01184098e+00 2.59558789 0.70441690 559.75 -3.59513501e+00 1.68119324e+00 3.96880416e+00 2.70417467 0.66930709 560.00 -3.23881875e+00 1.03709187e+00 3.40080968e+00 2.83170211 0.60917986 560.25 -3.70423609e+00 9.44557442e-01 3.82276782e+00 2.89191944 0.68178842 560.50 -4.66154572e+00 1.32118052e+00 4.84515494e+00 2.86541437 0.80055962 560.75 -4.72552040e+00 1.80389744e+00 5.05812109e+00 2.77693027 0.77118479 561.00 -4.76269809e+00 2.43448395e+00 5.34883214e+00 2.66905975 0.77143613 561.25 -5.23537084e+00 3.16486170e+00 6.11763495e+00 2.59785970 0.82074567 561.50 -5.76378773e+00 3.98050744e+00 7.00469046e+00 2.53719913 0.84457853 561.75 -5.45313074e+00 4.21024705e+00 6.88932617e+00 2.48411016 0.80367952 562.00 -5.07817285e+00 4.97134464e+00 7.10648345e+00 2.36682427 0.84113631 562.25 -5.37311061e+00 4.80994150e+00 7.21150850e+00 2.41144276 0.84932538 562.50 -5.34257327e+00 4.64859196e+00 7.08184273e+00 2.42554260 0.88408454 562.75 -4.54787960e+00 5.01328352e+00 6.76876802e+00 2.30755638 0.85173169 563.00 -4.64638278e+00 6.10458889e+00 7.67169333e+00 2.22138236 0.78746969 563.25 -3.88113589e+00 6.48604482e+00 7.55857084e+00 2.11002566 0.72821647 563.50 -3.49558405e+00 6.90968441e+00 7.74356807e+00 2.03914987 0.72941621 563.75 -2.01583457e+00 5.79341951e+00 6.13410945e+00 1.90564589 0.60566099 564.00 -7.25835025e-01 6.69213765e+00 6.73138491e+00 1.67883486 0.62149983 564.25 5.14260694e-01 5.72566715e+00 5.74871537e+00 1.48121995 0.43138028 564.50 6.55315474e-01 4.56230638e+00 4.60912984e+00 1.42813521 0.33401946 564.75 -7.67746845e-01 4.16233396e+00 4.23254761e+00 1.75319725 0.26494543 565.00 -1.87975658e+00 5.52279994e+00 5.83393554e+00 1.89886015 0.45173563 565.25 -3.50084560e+00 6.55180896e+00 7.42846690e+00 2.06153136 0.46407601 565.50 -4.10568900e+00 8.22844259e+00 9.19586590e+00 2.03361405 0.48712464 565.75 8.20737172e-01 7.94163063e+00 7.98392801e+00 1.46781574 0.38749202 566.00 2.89268683e+00 6.82926332e+00 7.41663499e+00 1.17013557 0.38822639 566.25 1.18049070e+00 2.55917893e+00 2.81832487e+00 1.13860401 0.07131952 566.50 -4.56984789e-01 3.48209812e+00 3.51195707e+00 1.70128890 0.10239656 566.75 -2.37957970e+00 4.90133090e+00 5.44843502e+00 2.02277408 0.34677185 567.00 -1.96614543e+00 6.19485274e+00 6.49937907e+00 1.87812422 0.49851306 567.25 -4.90743623e-01 8.07314192e+00 8.08804363e+00 1.63150881 0.77180289 567.50 1.11822392e-01 8.37085829e+00 8.37160515e+00 1.55743859 0.80113568 567.75 1.51407506e+00 9.47441885e+00 9.59463578e+00 1.41232960 0.88687450 568.00 2.34354845e+00 9.26826588e+00 9.55996715e+00 1.32313028 0.90309770 568.25 4.56354044e+00 8.58497275e+00 9.72253354e+00 1.08221044 0.93748541 568.50 5.25960853e+00 8.02639066e+00 9.59616741e+00 0.99071172 0.95704834 568.75 6.25652949e+00 6.50777929e+00 9.02747764e+00 0.80507940 0.96519223 569.00 6.58292098e+00 5.82097577e+00 8.78741188e+00 0.72404736 0.97344019 569.25 6.71419422e+00 4.71972342e+00 8.20708189e+00 0.61270115 0.97817248 569.50 6.66449815e+00 4.01220737e+00 7.77903231e+00 0.54190856 0.97134554 569.75 6.22609777e+00 3.09231511e+00 6.95174124e+00 0.46097995 0.97705247 570.00 6.24333515e+00 2.85959704e+00 6.86706116e+00 0.42950658 0.98236844 570.25 6.13712482e+00 2.62526246e+00 6.67505087e+00 0.40421240 0.98307410 570.50 6.02150056e+00 2.25095513e+00 6.42847322e+00 0.35773543 0.98015912 570.75 6.03343686e+00 1.67852020e+00 6.26257059e+00 0.27134156 0.98271243 571.00 5.80912734e+00 1.36069653e+00 5.96636032e+00 0.23008615 0.97853606 571.25 5.46459277e+00 1.02100942e+00 5.55915770e+00 0.18471116 0.98142296 571.50 5.38414469e+00 6.88037284e-01 5.42792864e+00 0.12710065 0.97789297 571.75 5.20539906e+00 1.94860551e-01 5.20904502e+00 0.03741684 0.97681259 572.00 4.93220270e+00 -8.88488868e-02 4.93300289e+00 -0.01801209 0.96366028 572.25 4.57684106e+00 -5.67948685e-01 4.61194534e+00 -0.12346072 0.95652165 572.50 4.05809804e+00 -7.97043113e-01 4.13563024e+00 -0.19393939 0.93407647 572.75 3.70482371e+00 -7.76746385e-01 3.78537365e+00 -0.20666473 0.95366131 573.00 3.33700894e+00 -8.53620452e-01 3.44445881e+00 -0.25043381 0.94994923 573.25 2.76328887e+00 -7.60118312e-01 2.86592833e+00 -0.26843817 0.91504330 573.50 2.32606919e+00 -4.70372972e-01 2.37315162e+00 -0.19952730 0.84987017 573.75 2.08124497e+00 -1.28852920e-01 2.08522989e+00 -0.06183254 0.87992297 574.00 2.18393197e+00 2.26429130e-01 2.19563863e+00 0.10331045 0.89311952 574.25 2.36783600e+00 5.03372212e-01 2.42075007e+00 0.20946906 0.92411760 574.50 2.69875238e+00 6.72005218e-01 2.78116080e+00 0.24404280 0.93242785 574.75 3.01968104e+00 8.42143581e-01 3.13491298e+00 0.27197441 0.95160915 575.00 3.44363080e+00 7.98890846e-01 3.53508411e+00 0.22795839 0.94943409 575.25 3.65164994e+00 6.55900806e-01 3.71008803e+00 0.17772257 0.96475340 575.50 3.76212755e+00 2.62562047e-01 3.77127863e+00 0.06967786 0.96309828 575.75 3.89064125e+00 -8.04517725e-03 3.89064957e+00 -0.00206783 0.96381530 576.00 3.94080389e+00 -2.41886595e-01 3.94822042e+00 -0.06130310 0.96276509 576.25 3.85153736e+00 -2.87788051e-01 3.86227420e+00 -0.07458171 0.96046455 576.50 3.45269812e+00 -6.10203433e-01 3.50620486e+00 -0.17492604 0.96372145 576.75 3.29389950e+00 -6.64957576e-01 3.36034856e+00 -0.19919826 0.95392533 577.00 2.95089425e+00 -5.67907576e-01 3.00504507e+00 -0.19012812 0.91926032 577.25 2.79148156e+00 -4.59784337e-01 2.82909366e+00 -0.16324409 0.91053203 577.50 2.76503958e+00 -1.19129772e-03 2.76503984e+00 -0.00043084 0.89339296 577.75 2.80244754e+00 4.79570075e-02 2.80285785e+00 0.01711087 0.90987633 578.00 3.18980890e+00 1.13640079e-01 3.19183253e+00 0.03561092 0.86375760 578.25 3.40618512e+00 1.17889147e-01 3.40822460e+00 0.03459651 0.85275483 578.50 3.54408443e+00 2.55479653e-01 3.55328078e+00 0.07196175 0.83467274 578.75 3.85599279e+00 2.86796867e-01 3.86664362e+00 0.07424022 0.84833419 579.00 4.41507486e+00 9.29473714e-02 4.41605313e+00 0.02104917 0.81591810 579.25 4.67105235e+00 7.80372140e-02 4.67170417e+00 0.01670501 0.79741265 579.50 5.39139394e+00 -9.92298842e-02 5.39230704e+00 -0.01840316 0.82524566 579.75 6.06157059e+00 -2.78013804e-01 6.06794279e+00 -0.04583286 0.81922798 580.00 6.52525042e+00 -9.89474272e-01 6.59984487e+00 -0.15049127 0.80704052 580.25 6.75791528e+00 -1.89496303e+00 7.01856850e+00 -0.27338556 0.80997860 580.50 7.38476204e+00 -2.72944403e+00 7.87302833e+00 -0.35403233 0.78755056 580.75 6.87461877e+00 -3.46091979e+00 7.69664531e+00 -0.46639138 0.72080363 581.00 5.51357650e+00 -5.62634000e+00 7.87751406e+00 -0.79552029 0.66768666 581.25 4.27880810e+00 -6.22743232e+00 7.55573372e+00 -0.96878727 0.59858896 581.50 1.50609387e+00 -6.66095302e+00 6.82910052e+00 -1.34842765 0.68819428 581.75 5.50358816e-01 -5.66522179e+00 5.69189184e+00 -1.47395330 0.63725660 582.00 -4.88520070e-01 -4.32852086e+00 4.35600099e+00 -1.68318151 0.49622768 582.25 -6.96989441e-01 -2.65975785e+00 2.74956471e+00 -1.82708358 0.20671244 582.50 -3.20051504e-01 -4.70418590e-01 5.68969784e-01 -2.16821550 0.00685089 582.75 2.75358638e+00 -8.95822157e-01 2.89564073e+00 -0.31452965 0.23057564 583.00 3.80426218e+00 -1.34362936e+00 4.03456944e+00 -0.33951433 0.43837064 583.25 4.50079565e+00 -2.09377786e+00 4.96397695e+00 -0.43542352 0.59641588 583.50 4.47587114e+00 -2.52474593e+00 5.13884855e+00 -0.51358830 0.62857961 583.75 3.45878605e+00 -2.57974876e+00 4.31489335e+00 -0.64084226 0.54813325 584.00 2.94452618e+00 -1.71473219e+00 3.40742438e+00 -0.52733725 0.47037830 584.25 2.53290979e+00 -1.22875968e+00 2.81522332e+00 -0.45167114 0.25317079 584.50 3.05053857e+00 -6.72404444e-01 3.12376588e+00 -0.21695236 0.23533083 584.75 4.17522766e+00 -2.10316399e-01 4.18052138e+00 -0.05032990 0.37146191 585.00 3.99509771e+00 -1.48654758e-01 3.99786242e+00 -0.03719213 0.31489506 585.25 3.82198347e+00 3.42383095e+00 5.13129379e+00 0.73050406 0.38262146 585.50 4.47147987e+00 5.03447582e+00 6.73350421e+00 0.84455466 0.52921439 585.75 1.02445914e+01 5.39971011e+00 1.15805234e+01 0.48507548 0.72595042 586.00 1.35679630e+01 4.13022081e+00 1.41826776e+01 0.29549755 0.77067821 586.25 1.83860389e+01 -1.83204165e+00 1.84770886e+01 -0.09931526 0.73850569 586.50 1.93023283e+01 -7.32679238e+00 2.06461078e+01 -0.36278061 0.74702156 586.75 1.11016588e+01 -1.37072812e+01 1.76390585e+01 -0.89004208 0.71962436 587.00 6.90577672e+00 -1.37727902e+01 1.54071251e+01 -1.10602356 0.78466041 587.25 1.02171294e+00 -1.29865157e+01 1.30266453e+01 -1.49228314 0.78240736 587.50 -1.73978959e+00 -1.23150824e+01 1.24373680e+01 -1.71114065 0.76219612 587.75 -6.08351054e+00 -8.40826243e+00 1.03782454e+01 -2.19713097 0.65370266 588.00 -6.49748559e+00 -5.65043714e+00 8.61073509e+00 -2.42580966 0.64414781 588.25 -6.48539676e+00 1.14103619e-01 6.48640044e+00 3.12400054 0.54171961 588.50 -6.26753069e+00 1.75867608e+00 6.50959925e+00 2.86802663 0.55165979 588.75 -3.56669652e+00 4.57454917e+00 5.80067446e+00 2.23302527 0.52546714 589.00 -2.79103201e+00 5.12260149e+00 5.83360144e+00 2.06967439 0.61397789 589.25 -1.80112915e+00 5.22005841e+00 5.52205361e+00 1.90304566 0.52891401 589.50 -1.06208360e+00 7.20840748e+00 7.28623085e+00 1.71708337 0.63550219 589.75 2.57814599e-01 7.15468744e+00 7.15933103e+00 1.53477755 0.61857355 590.00 1.23697915e+00 5.79565879e+00 5.92619425e+00 1.36051935 0.57802574 590.25 2.07806728e+00 6.42493224e+00 6.75263785e+00 1.25797784 0.60188741 590.50 1.84376782e+00 6.80493241e+00 7.05028970e+00 1.30620317 0.62839609 590.75 2.10393461e+00 6.41939856e+00 6.75538442e+00 1.25408243 0.70814393 591.00 2.40154313e+00 6.39514269e+00 6.83119751e+00 1.21156448 0.68227011 591.25 2.31468888e+00 5.86141114e+00 6.30189854e+00 1.19469162 0.63569530 591.50 2.08910183e+00 5.85986654e+00 6.22112388e+00 1.22833364 0.66807283 591.75 1.97974854e+00 6.05241112e+00 6.36797335e+00 1.25466550 0.75912173 592.00 1.42359122e+00 5.47120175e+00 5.65337604e+00 1.31624359 0.70664659 592.25 9.58261822e-01 4.97172243e+00 5.06322917e+00 1.38038885 0.69816991 592.50 -5.65772084e-01 5.04613665e+00 5.07775474e+00 1.68244987 0.65856712 592.75 -2.06941427e+00 5.26756338e+00 5.65947872e+00 1.94513231 0.73782499 593.00 -2.59649179e+00 5.27546799e+00 5.87982416e+00 2.02817021 0.70033064 593.25 -3.08791546e+00 7.11992506e+00 7.76070581e+00 1.98001328 0.74381549 593.50 -2.51119912e+00 9.66513081e+00 9.98603398e+00 1.82499624 0.82697935 593.75 -1.85242759e+00 1.12095469e+01 1.13615769e+01 1.73457065 0.88334241 594.00 -5.77033875e-01 1.26430511e+01 1.26562123e+01 1.61640507 0.89929966 594.25 7.90802282e-01 1.36196757e+01 1.36426147e+01 1.51279822 0.90657681 594.50 1.49062641e+00 1.45754833e+01 1.46515078e+01 1.46888122 0.90235741 594.75 2.36853442e+00 1.44102794e+01 1.46036334e+01 1.40788870 0.89067694 595.00 3.94838329e+00 1.25287845e+01 1.31362160e+01 1.26550363 0.88385029 595.25 4.71908128e+00 1.14340503e+01 1.23696093e+01 1.17937125 0.85148006 595.50 4.86978673e+00 9.57060710e+00 1.07383119e+01 1.10011179 0.79275758 595.75 3.74449281e+00 8.88815061e+00 9.64471087e+00 1.17207191 0.78563833 596.00 2.15123911e+00 1.02498621e+01 1.04731802e+01 1.36391925 0.79360497 596.25 4.12765108e-01 1.15023727e+01 1.15097764e+01 1.53492650 0.77142524 596.50 1.78291573e+00 1.32391602e+01 1.33586733e+01 1.43693185 0.76835633 596.75 1.32961569e+00 1.44565627e+01 1.45175784e+01 1.47908120 0.79279860 597.00 -2.74645325e-01 1.70381924e+01 1.70404058e+01 1.58691432 0.78270753 597.25 1.61473747e+00 1.86019367e+01 1.86718886e+01 1.48420857 0.76926390 597.50 3.76260726e+00 2.17089199e+01 2.20325763e+01 1.39918043 0.74814452 597.75 4.54657759e+00 2.23280671e+01 2.27862667e+01 1.36991656 0.67544691 598.00 2.08235393e+00 2.44321799e+01 2.45207588e+01 1.48577184 0.42656952 598.25 3.99133274e+00 1.89730559e+01 1.93883364e+01 1.36345125 0.24026621 598.50 9.55821941e-01 -2.52602662e+00 2.70081581e+00 -1.20905736 0.00464068 598.75 2.48556681e+00 -1.13783568e+01 1.16466753e+01 -1.35572790 0.10637831 599.00 2.29529135e+00 -1.66962300e+01 1.68532626e+01 -1.43417905 0.36766605 599.25 6.76701532e-01 -1.33832697e+01 1.34003669e+01 -1.52027611 0.30676439 599.50 1.14159981e+00 -1.05028706e+01 1.05647310e+01 -1.46252729 0.32319146 599.75 3.81101481e-01 -9.91849296e+00 9.92581185e+00 -1.53239189 0.39003928 600.00 -4.55655267e-01 -1.09466919e+01 1.09561711e+01 -1.61239724 0.72912496 600.25 4.88772901e-01 -1.02195441e+01 1.02312258e+01 -1.52300547 0.74775233 600.50 1.84145108e+00 -9.02795699e+00 9.21384553e+00 -1.36958440 0.81281079 600.75 1.17423411e+00 -9.75126717e+00 9.82171254e+00 -1.45095475 0.83973737 601.00 6.47959450e-01 -1.06801193e+01 1.06997570e+01 -1.51020092 0.83496245 601.25 6.06229136e-01 -1.03207085e+01 1.03384978e+01 -1.51212464 0.82832641 601.50 1.56961833e-01 -1.04450143e+01 1.04461936e+01 -1.55577002 0.83637510 601.75 -6.82104398e-01 -1.00604312e+01 1.00835283e+01 -1.63849343 0.76535995 602.00 -2.29877847e+00 -8.96250001e+00 9.25260984e+00 -1.82187246 0.71384321 602.25 -2.72081454e+00 -8.39966014e+00 8.82933305e+00 -1.88405073 0.72871947 602.50 -2.80351559e+00 -7.53355860e+00 8.03829614e+00 -1.92705457 0.73433458 602.75 -2.57749176e+00 -5.70738492e+00 6.26240420e+00 -1.99498536 0.62539669 603.00 -2.92615890e+00 -4.42917940e+00 5.30848717e+00 -2.15462536 0.61974877 603.25 -1.60513345e+00 -3.67865623e+00 4.01359752e+00 -1.98223011 0.47410301 603.50 -1.05500865e+00 -2.94956046e+00 3.13256287e+00 -1.91429953 0.48957118 603.75 -4.12243174e-01 -2.51857154e+00 2.55208680e+00 -1.73303897 0.43050453 604.00 1.28651335e-01 -1.91606378e+00 1.92037798e+00 -1.50375340 0.35791968 604.25 1.95375960e-01 -6.99566884e-01 7.26337105e-01 -1.29845418 0.03936716 604.50 4.19831769e-01 8.12056460e-01 9.14163229e-01 1.09364277 0.06970824 604.75 6.86599845e-01 1.79578974e+00 1.92257123e+00 1.20560733 0.14257127 605.00 6.90640067e-01 2.50115642e+00 2.59475763e+00 1.30138145 0.15541028 605.25 1.17535875e+00 1.30568958e+00 1.75678498e+00 0.83788047 0.03809694 605.50 1.22959502e+00 2.61635124e+00 2.89088183e+00 1.13146364 0.06002889 605.75 1.10460924e+00 -1.57055197e+00 1.92010288e+00 -0.95784197 0.02001141 606.00 -8.06120156e-01 -3.67544070e+00 3.76280401e+00 -1.78670377 0.07260745 606.25 -1.35389948e-01 -6.15230788e+00 6.15379742e+00 -1.59279914 0.26386989 606.50 1.25900834e+00 -7.40573131e+00 7.51198764e+00 -1.40240171 0.33335730 606.75 -8.31174929e-02 -9.23203971e+00 9.23241386e+00 -1.57979924 0.46169025 607.00 1.07967066e+00 -1.00091013e+01 1.00671643e+01 -1.46334291 0.60608902 607.25 2.89266551e+00 -9.86173883e+00 1.02772276e+01 -1.28547729 0.65868625 607.50 3.11944876e+00 -1.00373176e+01 1.05108851e+01 -1.26947455 0.68629515 607.75 6.42540825e+00 -1.03329324e+01 1.21678003e+01 -1.01447417 0.65528592 608.00 8.24725165e+00 -9.81682385e+00 1.28213568e+01 -0.87206964 0.65818398 608.25 1.01158926e+01 -8.67579007e+00 1.33266881e+01 -0.70891256 0.71292790 608.50 1.11822644e+01 -6.90648693e+00 1.31431579e+01 -0.55328101 0.67685153 608.75 1.11055892e+01 -2.91545429e+00 1.14818981e+01 -0.25672831 0.61673217 609.00 1.14625469e+01 -2.60113030e+00 1.17539721e+01 -0.22314525 0.60397412 609.25 1.44313512e+01 -3.78048359e+00 1.49183093e+01 -0.25620611 0.63152792 609.50 1.42838272e+01 -4.71327291e+00 1.50413650e+01 -0.31872293 0.60229422 609.75 1.29648252e+01 -3.94699308e+00 1.35523225e+01 -0.29552390 0.55960694 610.00 1.15999867e+01 -3.33198451e+00 1.20690435e+01 -0.27971000 0.57678585 610.25 9.84140171e+00 -3.28492385e+00 1.03751584e+01 -0.32215806 0.54433397 610.50 9.24884223e+00 -2.94397342e+00 9.70608377e+00 -0.30816667 0.54719886 610.75 9.00654676e+00 -6.59487026e-01 9.03065932e+00 -0.07309263 0.70369834 611.00 9.39111734e+00 2.54684801e-01 9.39457020e+00 0.02711311 0.81130734 611.25 9.18598293e+00 2.73878598e+00 9.58557411e+00 0.28975720 0.82680504 611.50 9.28476324e+00 4.18341763e+00 1.01837032e+01 0.42332621 0.83173484 611.75 9.34415503e+00 5.73088650e+00 1.09615826e+01 0.55015060 0.84174685 612.00 9.14341885e+00 6.47398302e+00 1.12033283e+01 0.61610717 0.86190518 612.25 1.00133678e+01 8.51646766e+00 1.31452561e+01 0.70478997 0.89154505 612.50 1.01124891e+01 9.79322178e+00 1.40772735e+01 0.76936056 0.90323891 612.75 1.08048206e+01 1.09395646e+01 1.53758974e+01 0.79159481 0.89472069 613.00 1.16573246e+01 1.18837962e+01 1.66468564e+01 0.79501812 0.88711573 613.25 1.30711767e+01 1.32361493e+01 1.86024544e+01 0.79166906 0.91785190 613.50 1.46463389e+01 1.24947339e+01 1.92518471e+01 0.70628874 0.89908112 613.75 1.73387118e+01 1.04569689e+01 2.02479413e+01 0.54269545 0.86071364 614.00 1.67868395e+01 8.66066830e+00 1.88892868e+01 0.47630244 0.85287157 614.25 1.72296688e+01 6.91211265e+00 1.85644496e+01 0.38151891 0.87532535 614.50 1.59177686e+01 6.14209502e+00 1.70616731e+01 0.36826115 0.88422915 614.75 1.50181236e+01 5.34807462e+00 1.59419553e+01 0.34210589 0.89576002 615.00 1.44955460e+01 4.73302762e+00 1.52486854e+01 0.31560245 0.88704818 615.25 1.49244654e+01 4.32154764e+00 1.55375494e+01 0.28185271 0.92777015 615.50 1.45428003e+01 3.01992852e+00 1.48530471e+01 0.20474804 0.95034346 615.75 1.39264234e+01 2.32429764e+00 1.41190520e+01 0.16537413 0.95876814 616.00 1.32251129e+01 1.97015501e+00 1.33710554e+01 0.14788320 0.95525530 616.25 1.28628089e+01 1.87230716e+00 1.29983610e+01 0.14454459 0.96954985 616.50 1.19705266e+01 1.96398972e+00 1.21305714e+01 0.16261995 0.96934500 616.75 1.15441659e+01 2.26659387e+00 1.17645745e+01 0.19387489 0.97348387 617.00 1.11612841e+01 2.92842799e+00 1.15390621e+01 0.25659022 0.96455042 617.25 1.11628632e+01 2.87668233e+00 1.15275677e+01 0.25221354 0.96675732 617.50 1.07935992e+01 2.81423110e+00 1.11544467e+01 0.25505310 0.97199061 617.75 1.03822491e+01 2.92961180e+00 1.07876653e+01 0.27502450 0.97767623 618.00 9.77607920e+00 3.28652176e+00 1.03137263e+01 0.32431031 0.97479640 618.25 9.69500660e+00 3.34449123e+00 1.02556704e+01 0.33218718 0.97346143 618.50 8.87607034e+00 3.36941792e+00 9.49408246e+00 0.36280350 0.97254703 618.75 8.63202720e+00 3.62026954e+00 9.36046181e+00 0.39711759 0.97036756 619.00 8.06963683e+00 4.48814608e+00 9.23376921e+00 0.50757323 0.93666710 619.25 8.08998578e+00 5.27626252e+00 9.65851004e+00 0.57791797 0.94409941 619.50 9.25829015e+00 5.71566505e+00 1.08804763e+01 0.55308393 0.94725952 619.75 9.89783711e+00 6.76640678e+00 1.19896389e+01 0.59965114 0.95327462 620.00 9.96626522e+00 7.74171581e+00 1.26198497e+01 0.66042871 0.95258767 620.25 1.07036548e+01 7.95506487e+00 1.33360895e+01 0.63914142 0.94189878 620.50 1.27664730e+01 6.85531079e+00 1.44906217e+01 0.49279031 0.94120779 620.75 1.34287386e+01 6.14521165e+00 1.47680279e+01 0.42916968 0.95149533 621.00 1.44033449e+01 6.20287673e+00 1.56822200e+01 0.40665096 0.97023675 621.25 1.45813202e+01 5.60206578e+00 1.56204366e+01 0.36680730 0.96980629 621.50 1.50498283e+01 4.41883516e+00 1.56851343e+01 0.28558752 0.96068524 621.75 1.54689647e+01 3.53788342e+00 1.58683801e+01 0.22484141 0.94955179 622.00 1.56461791e+01 2.44185155e+00 1.58355789e+01 0.15481806 0.96284158 622.25 1.51154296e+01 2.38958884e+00 1.53031483e+01 0.15679178 0.95022972 622.50 1.39412156e+01 8.76849020e-01 1.39687636e+01 0.06281343 0.91325140 622.75 1.42823448e+01 2.75416203e-01 1.42850001e+01 0.01928129 0.93053559 623.00 1.46528872e+01 4.03147676e-01 1.46584321e+01 0.02750625 0.93313305 623.25 1.40248098e+01 -4.79275549e-01 1.40329967e+01 -0.03416011 0.89204790 623.50 1.44835526e+01 -2.36374628e+00 1.46751692e+01 -0.16177587 0.89511284 623.75 1.40866529e+01 -2.93403214e+00 1.43889657e+01 -0.20534863 0.86916395 624.00 1.38579730e+01 -2.77690809e+00 1.41334580e+01 -0.19776421 0.80598613 624.25 1.40195634e+01 -3.65550686e+00 1.44883018e+01 -0.25506414 0.80375816 624.50 1.45896640e+01 -5.27739568e+00 1.55148059e+01 -0.34707877 0.87268277 624.75 1.40515390e+01 -5.92956170e+00 1.52514081e+01 -0.39931554 0.84936543 625.00 1.35596107e+01 -7.07827372e+00 1.52959145e+01 -0.48110141 0.82910559 625.25 1.36504744e+01 -8.98322689e+00 1.63411693e+01 -0.58204068 0.76647546 625.50 1.12517662e+01 -1.22668463e+01 1.66456529e+01 -0.82853211 0.70614377 625.75 7.91171157e+00 -1.45768837e+01 1.65855576e+01 -1.07353065 0.77150494 626.00 6.04154501e+00 -1.59376143e+01 1.70442899e+01 -1.20845819 0.88304068 626.25 3.04549321e+00 -1.54867410e+01 1.57833512e+01 -1.37662239 0.88846120 626.50 8.78429258e-01 -1.43100408e+01 1.43369768e+01 -1.50948774 0.92284891 626.75 -8.14929032e-01 -1.24544644e+01 1.24810975e+01 -1.63613587 0.90533502 627.00 -1.57154892e+00 -1.12016926e+01 1.13113962e+01 -1.71018224 0.92327615 627.25 -2.68118541e+00 -9.79518499e+00 1.01555110e+01 -1.83797664 0.94280198 627.50 -3.29020636e+00 -9.44749461e+00 1.00040298e+01 -1.90592226 0.94948594 627.75 -3.86687429e+00 -6.81388236e+00 7.83464802e+00 -2.08697545 0.89561226 628.00 -4.28093932e+00 -5.51795386e+00 6.98385683e+00 -2.23061853 0.89101077 628.25 -3.92007987e+00 -3.75775697e+00 5.43026368e+00 -2.37733309 0.81229005 628.50 -3.54250980e+00 -2.44761078e+00 4.30583025e+00 -2.53698288 0.75782947 628.75 -2.56925777e+00 -1.26839458e+00 2.86529411e+00 -2.68301275 0.63481837 629.00 -1.91591901e+00 -1.02214523e+00 2.17152631e+00 -2.65150459 0.42434219 629.25 2.36894356e-01 -7.53955166e-01 7.90295722e-01 -1.26636147 0.08978458 629.50 1.03784234e+00 -9.68181578e-01 1.41932811e+00 -0.75068633 0.29727227 629.75 1.74413130e+00 -1.86713147e+00 2.55502914e+00 -0.81944516 0.60229023 630.00 1.88603815e+00 -2.15975012e+00 2.86734381e+00 -0.85294879 0.65565333 630.25 1.32236547e+00 -2.50952304e+00 2.83661001e+00 -1.08583053 0.67288037 630.50 1.03753807e+00 -2.52683657e+00 2.73155419e+00 -1.18117912 0.67516855 630.75 7.15387968e-01 -2.02197089e+00 2.14479515e+00 -1.23073378 0.55710668 631.00 8.95201152e-01 -1.70173845e+00 1.92283615e+00 -1.08652580 0.56456887 631.25 1.06419551e+00 -1.46870841e+00 1.81372999e+00 -0.94376404 0.55526158 631.50 1.33157464e+00 -1.38080916e+00 1.91826092e+00 -0.80354792 0.60360097 631.75 1.93155380e+00 -9.74637574e-01 2.16351993e+00 -0.46731074 0.66732838 632.00 2.02310667e+00 -9.10022941e-01 2.21835578e+00 -0.42269975 0.63820069 632.25 2.37054848e+00 -9.74013892e-01 2.56285059e+00 -0.38985142 0.63610119 632.50 2.43793287e+00 -1.56531521e+00 2.89719319e+00 -0.57077789 0.66454960 632.75 2.21362517e+00 -2.59876976e+00 3.41375756e+00 -0.86525974 0.68443567 633.00 1.96058095e+00 -3.05696909e+00 3.63165771e+00 -1.00052744 0.73089788 633.25 1.33675017e+00 -3.19364155e+00 3.46211602e+00 -1.17438783 0.75648040 633.50 1.21436170e+00 -3.03113830e+00 3.26534435e+00 -1.18974788 0.78965091 633.75 1.23584754e+00 -2.80786484e+00 3.06780444e+00 -1.15617398 0.83674278 634.00 1.00240480e+00 -2.84565371e+00 3.01704498e+00 -1.23211118 0.80012865 634.25 7.05625997e-01 -2.41508119e+00 2.51605350e+00 -1.28653393 0.80263711 634.50 7.45606238e-01 -2.13011700e+00 2.25684007e+00 -1.23409420 0.77206141 634.75 9.97692831e-01 -1.86899776e+00 2.11861833e+00 -1.08046666 0.76734277 635.00 1.43150981e+00 -1.63172451e+00 2.17065548e+00 -0.85066588 0.75193171 635.25 2.00817037e+00 -1.40129762e+00 2.44875136e+00 -0.60924670 0.85013253 635.50 2.66443525e+00 -1.51321856e+00 3.06415496e+00 -0.51650642 0.86055321 635.75 3.06397869e+00 -1.86694565e+00 3.58795923e+00 -0.54724479 0.87876937 636.00 3.16378510e+00 -2.48465084e+00 4.02281319e+00 -0.66573853 0.84146843 636.25 3.44115884e+00 -3.11315125e+00 4.64039706e+00 -0.73539532 0.88116177 636.50 3.71605042e+00 -3.75239473e+00 5.28105074e+00 -0.79026451 0.87992387 636.75 3.80457632e+00 -4.46495349e+00 5.86605580e+00 -0.86508574 0.90371612 637.00 4.15623527e+00 -5.17934995e+00 6.64077988e+00 -0.89455553 0.89208564 637.25 4.43421089e+00 -5.82354563e+00 7.31955668e+00 -0.92002131 0.91173983 637.50 4.36476869e+00 -7.40739620e+00 8.59771622e+00 -1.03832270 0.87993910 637.75 4.09952907e+00 -8.75850186e+00 9.67044432e+00 -1.13302331 0.93026291 638.00 3.40851010e+00 -1.04688393e+01 1.10097474e+01 -1.25603428 0.92623150 638.25 2.65845143e+00 -1.13436656e+01 1.16510134e+01 -1.34059514 0.91352379 638.50 5.21519620e-01 -1.31319398e+01 1.31422914e+01 -1.53110336 0.86892180 638.75 -1.63195801e+00 -1.45976916e+01 1.46886312e+01 -1.68212966 0.89079925 639.00 -5.81143947e+00 -1.37902111e+01 1.49647168e+01 -1.96962885 0.89555588 639.25 -7.87958502e+00 -1.26847652e+01 1.49328875e+01 -2.12664752 0.90280725 639.50 -9.64147494e+00 -1.03860377e+01 1.41713732e+01 -2.31903461 0.92647873 639.75 -9.93260978e+00 -8.79945565e+00 1.32697836e+01 -2.41661361 0.91669779 640.00 -1.00072157e+01 -5.77211185e+00 1.15525600e+01 -2.61841044 0.90185743 640.25 -9.52602498e+00 -5.05127967e+00 1.07824199e+01 -2.65403032 0.89495092 640.50 -8.12083740e+00 -3.43878749e+00 8.81891487e+00 -2.74103363 0.89706980 640.75 -7.60633316e+00 -3.19290791e+00 8.24930089e+00 -2.74416048 0.89975742 641.00 -6.45675217e+00 -2.81697550e+00 7.04450137e+00 -2.73020359 0.90072347 641.25 -6.61599926e+00 -2.66700524e+00 7.13332764e+00 -2.75840425 0.92015254 641.50 -5.88495732e+00 -3.08345909e+00 6.64382741e+00 -2.65896437 0.93243126 641.75 -5.67795125e+00 -3.35044772e+00 6.59277107e+00 -2.60849891 0.91557065 642.00 -5.92102055e+00 -4.21612560e+00 7.26871374e+00 -2.52281809 0.94338644 642.25 -6.08157957e+00 -4.07111623e+00 7.31844228e+00 -2.55168799 0.91343103 642.50 -6.52598392e+00 -3.25153132e+00 7.29115369e+00 -2.67935095 0.88921033 642.75 -6.34130438e+00 -3.11825870e+00 7.06651813e+00 -2.68457667 0.87570852 643.00 -5.30976932e+00 -3.04420515e+00 6.12052573e+00 -2.62102069 0.76371584 643.25 -4.88523536e+00 -3.39954659e+00 5.95167552e+00 -2.53363590 0.78020627 643.50 -4.79090782e+00 -4.10929651e+00 6.31182347e+00 -2.43262907 0.81918340 643.75 -3.71070048e+00 -4.37920758e+00 5.73992658e+00 -2.27374712 0.72343342 644.00 -2.68823043e+00 -4.36911401e+00 5.12988694e+00 -2.12237575 0.69082306 644.25 -1.25632043e+00 -3.53703874e+00 3.75352955e+00 -1.91208716 0.45960439 644.50 -1.01462663e+00 -3.70825735e+00 3.84455976e+00 -1.83787240 0.39659399 644.75 -3.53002103e-01 -2.26928620e+00 2.29657796e+00 -1.72511598 0.17756834 645.00 3.32293383e-01 -6.79521150e-01 7.56417798e-01 -1.11597842 0.02440444 645.25 -8.37562514e-02 1.30089947e+00 1.30359294e+00 1.63509093 0.07363907 645.50 -5.55482675e-01 2.44599549e+00 2.50827729e+00 1.79410755 0.25588293 645.75 -2.63979827e-01 3.63044977e+00 3.64003446e+00 1.64338129 0.48056710 646.00 -8.03053102e-01 4.10735976e+00 4.18512826e+00 1.76387631 0.65872029 646.25 -1.69812993e+00 3.45069368e+00 3.84589809e+00 2.02811415 0.66538340 646.50 -2.49633654e+00 3.14951112e+00 4.01884516e+00 2.24101539 0.72550053 646.75 -3.63705931e+00 2.75127319e+00 4.56045004e+00 2.49397287 0.76990875 647.00 -4.38453550e+00 2.54571558e+00 5.06999204e+00 2.61555075 0.82568205 647.25 -4.85461612e+00 2.42523254e+00 5.42669794e+00 2.67828713 0.81504691 647.50 -5.40696181e+00 2.80626486e+00 6.09182719e+00 2.66285331 0.78405031 647.75 -5.54461205e+00 3.22340388e+00 6.41350570e+00 2.61499339 0.67784017 648.00 -5.73791515e+00 3.35510481e+00 6.64683373e+00 2.61248018 0.65446840 648.25 -5.59696868e+00 3.63800451e+00 6.67541274e+00 2.56522059 0.58688246 648.50 -6.34475416e+00 3.90452724e+00 7.44991532e+00 2.58993045 0.63989036 648.75 -5.36407954e+00 4.46586513e+00 6.97977798e+00 2.44731677 0.47263596 649.00 -4.92436805e+00 4.13568928e+00 6.43065522e+00 2.44302569 0.39639673 649.25 -2.22474649e+00 4.19459607e+00 4.74806625e+00 2.05845462 0.24797184 649.50 -6.01748776e-01 4.39283094e+00 4.43385445e+00 1.70693330 0.22069596 649.75 3.00261709e+00 6.56183036e+00 7.21618508e+00 1.14164988 0.45466730 650.00 3.53219892e+00 6.54774480e+00 7.43971714e+00 1.07608686 0.57352635 650.25 2.59960562e+00 7.22553339e+00 7.67895058e+00 1.22543512 0.69730605 650.50 2.26347547e+00 7.76692610e+00 8.09002239e+00 1.28722507 0.77005617 650.75 4.28580169e+00 6.86834526e+00 8.09581761e+00 1.01292123 0.74793981 651.00 5.96918867e+00 6.19674817e+00 8.60412118e+00 0.80410062 0.78065746 651.25 6.16627098e+00 4.16606801e+00 7.44170817e+00 0.59417682 0.75702806 651.50 6.46029296e+00 2.55893497e+00 6.94863536e+00 0.37714152 0.70073217 651.75 5.38519853e+00 9.67666964e-01 5.47144794e+00 0.17779277 0.63953258 652.00 4.48176029e+00 5.48483149e-01 4.51519757e+00 0.12177565 0.67520395 652.25 3.05967429e+00 -1.04421761e+00 3.23295487e+00 -0.32888893 0.63468138 652.50 2.02601346e+00 -1.26250036e+00 2.38718196e+00 -0.55726434 0.55118871 652.75 7.17827011e-01 -9.32436119e-01 1.17673818e+00 -0.91471780 0.35001092 653.00 3.32908082e-02 -4.46264225e-01 4.47504230e-01 -1.49633537 0.09831587 653.25 -7.56212259e-01 3.11690848e-01 8.17929194e-01 2.75063591 0.40523069 653.50 -8.64246739e-01 8.25717848e-01 1.19529594e+00 2.37898918 0.60272072 653.75 -8.07795232e-01 1.69320931e+00 1.87603062e+00 2.01593988 0.75143509 654.00 -5.96891951e-01 2.34021339e+00 2.41513534e+00 1.82053049 0.82767489 654.25 -2.14644072e-01 2.72108374e+00 2.72953637e+00 1.64951516 0.89524871 654.50 1.55424121e-01 2.53809581e+00 2.54285018e+00 1.50963619 0.84394491 654.75 6.38176829e-01 2.09301473e+00 2.18814541e+00 1.27484293 0.76456436 655.00 7.59302397e-01 1.69338115e+00 1.85582323e+00 1.14927853 0.74765796 655.25 5.02779461e-01 1.03424337e+00 1.14997676e+00 1.11830402 0.69896564 655.50 1.66410997e-01 9.61803403e-01 9.76093441e-01 1.39947270 0.66632789 655.75 -1.41947233e-01 8.37071434e-01 8.49021556e-01 1.73877437 0.69944975 656.00 -3.29697931e-01 8.38441017e-01 9.00935106e-01 1.94545060 0.70764861 656.25 -6.19707662e-01 1.04838242e+00 1.21784370e+00 2.10465224 0.81265194 656.50 -7.69629368e-01 1.25923968e+00 1.47580959e+00 2.11940008 0.86828087 656.75 -8.83462017e-01 1.41761178e+00 1.67036772e+00 2.12810344 0.89589585 657.00 -8.17796256e-01 1.70823234e+00 1.89389768e+00 2.01729036 0.92563857 657.25 -7.21005516e-01 1.98415546e+00 2.11109494e+00 1.91934227 0.94596019 657.50 -3.89058880e-01 1.91775428e+00 1.95682097e+00 1.77095201 0.92492929 657.75 -9.11142263e-02 1.85171309e+00 1.85395339e+00 1.61996204 0.94607394 658.00 -9.74902837e-02 1.63091428e+00 1.63382549e+00 1.63050174 0.94901799 658.25 -7.80855993e-02 1.38215778e+00 1.38436176e+00 1.62723177 0.94130048 658.50 -2.65033375e-01 1.01123604e+00 1.04539037e+00 1.82711968 0.84116737 658.75 -4.52762560e-01 8.28145831e-01 9.43832322e-01 2.07111658 0.86507754 659.00 -9.00321635e-01 8.48160742e-01 1.23691378e+00 2.38601774 0.89800938 659.25 -1.13324966e+00 9.20913320e-01 1.46025208e+00 2.45919745 0.94049504 659.50 -1.35084021e+00 1.15028358e+00 1.77423831e+00 2.43620990 0.95020814 659.75 -1.43151048e+00 1.30653626e+00 1.93810713e+00 2.40180640 0.95898034 660.00 -1.40875006e+00 1.49062468e+00 2.05098481e+00 2.32796328 0.96552400 660.25 -1.37222082e+00 1.53714219e+00 2.06053296e+00 2.29956867 0.97279998 660.50 -1.48253517e+00 1.52068312e+00 2.12376733e+00 2.34349281 0.96910498 660.75 -1.53862673e+00 1.51906433e+00 2.16215833e+00 2.36259217 0.97086171 661.00 -1.75886018e+00 1.64499252e+00 2.40823370e+00 2.38963460 0.97135972 661.25 -1.92112837e+00 1.79528022e+00 2.62940398e+00 2.39004439 0.97116685 661.50 -2.10836441e+00 2.04411443e+00 2.93659740e+00 2.37166594 0.97427854 661.75 -2.12289017e+00 2.22258524e+00 3.07352368e+00 2.33325624 0.96904287 662.00 -2.09340238e+00 2.74773112e+00 3.45432480e+00 2.22184840 0.96773444 662.25 -1.95708931e+00 3.08686836e+00 3.65499041e+00 2.13584480 0.95778180 662.50 -1.52712285e+00 3.52946389e+00 3.84567544e+00 1.97915264 0.96614978 662.75 -1.37023914e+00 3.60590163e+00 3.85747091e+00 1.93394249 0.95779129 663.00 -8.64172332e-01 3.37025493e+00 3.47928328e+00 1.82180024 0.95136487 663.25 -7.11431541e-01 3.34624168e+00 3.42103321e+00 1.78028328 0.96375958 663.50 -4.83719425e-01 3.13117400e+00 3.16831739e+00 1.72406967 0.96633457 663.75 -4.60484472e-01 3.01071209e+00 3.04572376e+00 1.72256882 0.96614658 664.00 -5.24046629e-01 2.96337099e+00 3.00935084e+00 1.74582810 0.96803611 664.25 -4.62378103e-01 2.97746652e+00 3.01315456e+00 1.72485821 0.95591201 664.50 -3.21616276e-01 3.16792183e+00 3.18420567e+00 1.67197247 0.93934444 664.75 -1.12274569e-01 3.37636364e+00 3.37822986e+00 1.60403718 0.90341672 665.00 2.53465112e-01 3.61564391e+00 3.62451727e+00 1.50080848 0.83760924 665.25 1.09728047e+00 3.34321751e+00 3.51868267e+00 1.25366301 0.70596944 665.50 2.00575458e+00 2.52791921e+00 3.22698419e+00 0.90006763 0.73473031 665.75 1.68427607e+00 1.52400188e+00 2.27142414e+00 0.73548321 0.43036158 666.00 1.24386405e+00 2.62706987e-01 1.27130355e+00 0.20814346 0.23294447 666.25 7.38617994e-01 -1.69781325e-01 7.57880096e-01 -0.22593875 0.15095341 666.50 2.29937449e-01 -2.70294632e-01 3.54866762e-01 -0.86590073 0.07321034 666.75 -6.11691961e-02 -2.63439208e-03 6.12258979e-02 -3.09855195 0.00279662 667.00 -2.54546146e-01 1.64286901e-01 3.02958621e-01 2.56845016 0.09584935 667.25 -1.70168112e-01 2.91783095e-01 3.37778864e-01 2.09877183 0.14048638 667.50 -7.64792747e-02 2.93515946e-01 3.03316155e-01 1.82569128 0.16147383 667.75 -1.83873679e-01 2.81517453e-01 3.36246347e-01 2.14938415 0.24309151 668.00 -2.73768242e-01 1.69147099e-01 3.21807072e-01 2.58815305 0.22127477 668.25 -3.83444143e-01 1.55007310e-01 4.13589987e-01 2.75742783 0.27394233 668.50 -5.78480028e-01 1.68141219e-01 6.02420627e-01 2.85872620 0.45477386 668.75 -6.77261356e-01 1.92141955e-01 7.03989684e-01 2.86515227 0.41761875 669.00 -7.44103410e-01 1.90286911e-01 7.68048822e-01 2.89123171 0.48420862 669.25 -3.58669474e-01 2.89914314e-01 4.61187707e-01 2.46180819 0.27346175 669.50 -2.37988078e-01 3.19894430e-01 3.98711389e-01 2.21041944 0.21545056 669.75 6.94638142e-02 -1.33678124e-01 1.50648805e-01 -1.09156449 0.02793595 670.00 -2.83622386e-02 -3.61911789e-01 3.63021432e-01 -1.64900430 0.12698639 670.25 -2.74096547e-01 -1.16057993e+00 1.19250773e+00 -1.80271871 0.47012590 670.50 -6.13691479e-01 -1.45626316e+00 1.58029100e+00 -1.96962673 0.59241397 670.75 -1.15530378e+00 -1.27992271e+00 1.72421836e+00 -2.30506564 0.66552843 671.00 -1.58040014e+00 -1.22725377e+00 2.00095387e+00 -2.48131729 0.78182184 671.25 -1.74365426e+00 -1.27846002e+00 2.16212632e+00 -2.50892579 0.75706465 671.50 -1.76361822e+00 -1.21939772e+00 2.14412687e+00 -2.53664954 0.73802950 671.75 -1.71439620e+00 -1.55936248e+00 2.31749124e+00 -2.40351563 0.84178016 672.00 -1.85087903e+00 -1.59234581e+00 2.44158112e+00 -2.43113848 0.86969503 672.25 -2.36649826e+00 -1.69838543e+00 2.91287265e+00 -2.51910006 0.89101150 672.50 -2.78880481e+00 -1.80746494e+00 3.32330585e+00 -2.56654403 0.91917109 672.75 -3.37052061e+00 -1.72730880e+00 3.78734800e+00 -2.66801463 0.93900926 673.00 -3.72118952e+00 -1.46706776e+00 3.99994241e+00 -2.76605559 0.93870130 673.25 -4.04453756e+00 -8.01381836e-01 4.12316588e+00 -2.94598687 0.94818114 673.50 -4.07855755e+00 -4.52000884e-01 4.10352733e+00 -3.03121934 0.94090576 673.75 -3.92013606e+00 -1.35417944e-01 3.92247431e+00 -3.10706219 0.94442543 674.00 -4.04744896e+00 -1.51518700e-01 4.05028407e+00 -3.10417452 0.93759137 674.25 -4.74054888e+00 -1.14278204e-02 4.74056265e+00 -3.13918200 0.93048084 674.50 -5.12764960e+00 2.83439287e-01 5.13547741e+00 3.08637220 0.89493809 674.75 -4.81939417e+00 1.19004851e+00 4.96414903e+00 2.89950636 0.79374848 675.00 -4.72028253e+00 2.34689323e+00 5.27152492e+00 2.68019286 0.79055234 675.25 -4.40062906e+00 3.49971384e+00 5.62259131e+00 2.46973896 0.89852628 675.50 -3.39949501e+00 3.66837893e+00 5.00135685e+00 2.31816972 0.90221353 675.75 -2.49109353e+00 3.37968933e+00 4.19855296e+00 2.20597572 0.94662910 676.00 -1.97023420e+00 3.15865781e+00 3.72275999e+00 2.12850114 0.93767035 676.25 -1.46750714e+00 2.97679933e+00 3.31887201e+00 2.02881342 0.92765798 676.50 -1.33290669e+00 2.70379851e+00 3.01449276e+00 2.02880864 0.93917402 676.75 -1.13797929e+00 2.55981413e+00 2.80136489e+00 1.98911334 0.95348185 677.00 -8.87141350e-01 2.40199749e+00 2.56058816e+00 1.92459105 0.94884603 677.25 -7.00840839e-01 2.14427915e+00 2.25590579e+00 1.88669350 0.94337921 677.50 -5.87332396e-01 1.88143646e+00 1.97098009e+00 1.87338265 0.90403011 677.75 -4.23403505e-01 1.60022516e+00 1.65529184e+00 1.82945888 0.87339417 678.00 -2.42871975e-01 1.13476454e+00 1.16046428e+00 1.78164374 0.72401888 678.25 -2.17408312e-01 7.91063583e-01 8.20395006e-01 1.83900484 0.63628790 678.50 -5.80823784e-01 2.34473986e-01 6.26365962e-01 2.75790747 0.42186260 678.75 -8.12510358e-01 -7.69833998e-02 8.16149205e-01 -3.04712706 0.67453092 679.00 -1.25780665e+00 -3.30486035e-01 1.30049936e+00 -2.88465243 0.78575498 679.25 -1.60091803e+00 -4.12029379e-01 1.65309006e+00 -2.88968899 0.90777323 679.50 -1.97033838e+00 -3.16389461e-01 1.99557902e+00 -2.98237562 0.92091718 679.75 -2.27062621e+00 -1.38402663e-01 2.27484036e+00 -3.08071445 0.93485982 680.00 -2.59213326e+00 6.60480821e-02 2.59297458e+00 3.11611796 0.91928952 680.25 -2.79372189e+00 2.86001376e-01 2.80832313e+00 3.03957516 0.93294497 680.50 -2.89088520e+00 6.86681127e-01 2.97132096e+00 2.90838145 0.93038042 680.75 -2.96795118e+00 8.51829228e-01 3.08777383e+00 2.86209624 0.94278449 681.00 -2.93529311e+00 1.03409971e+00 3.11212273e+00 2.80287154 0.95216556 681.25 -2.96804915e+00 1.21136075e+00 3.20573090e+00 2.75409423 0.94631076 681.50 -2.99280373e+00 1.67637564e+00 3.43032206e+00 2.63100118 0.93134570 681.75 -3.01253438e+00 1.92591357e+00 3.57554282e+00 2.57277613 0.94191973 682.00 -3.02313560e+00 2.49712745e+00 3.92109607e+00 2.45119445 0.96333250 682.25 -3.06696054e+00 2.65527924e+00 4.05669259e+00 2.42801483 0.95698212 682.50 -2.96847029e+00 3.11087034e+00 4.29992211e+00 2.33277517 0.93745903 682.75 -2.89143405e+00 3.55087697e+00 4.57920497e+00 2.25418853 0.93616125 683.00 -2.72334704e+00 3.87812003e+00 4.73882201e+00 2.18301993 0.93757049 683.25 -2.61456308e+00 4.40079117e+00 5.11887712e+00 2.10687521 0.92875667 683.50 -1.98452655e+00 5.79651037e+00 6.12681631e+00 1.90065390 0.91325884 683.75 -1.19894736e+00 6.06348625e+00 6.18088507e+00 1.76601050 0.91816028 684.00 -4.18972016e-01 6.60058972e+00 6.61387346e+00 1.63418622 0.93685005 684.25 1.95583444e-01 6.73444175e+00 6.73728125e+00 1.54176222 0.92091681 684.50 1.58716444e+00 6.10567055e+00 6.30858969e+00 1.31647581 0.92222641 684.75 1.99362280e+00 5.94494779e+00 6.27032185e+00 1.24723421 0.90743711 685.00 2.29728137e+00 4.99597554e+00 5.49884291e+00 1.13980089 0.86456307 685.25 2.69696010e+00 4.52731202e+00 5.26973889e+00 1.03353802 0.82787224 685.50 3.58983878e+00 4.29244327e+00 5.59571369e+00 0.87430040 0.86267736 685.75 3.11121647e+00 3.91017112e+00 4.99690965e+00 0.89869955 0.84765355 686.00 2.26730917e+00 3.74891435e+00 4.38121555e+00 1.02686157 0.83137403 686.25 2.20998781e+00 3.75637622e+00 4.35825750e+00 1.03900210 0.82312512 686.50 1.90759011e+00 4.23041734e+00 4.64061751e+00 1.14717556 0.85953203 686.75 1.41839321e+00 4.57563008e+00 4.79043108e+00 1.27020105 0.84188608 687.00 1.09894671e+00 5.62695785e+00 5.73326595e+00 1.37792374 0.88276270 687.25 1.41202801e+00 6.37282883e+00 6.52738619e+00 1.35274895 0.86999539 687.50 2.13434682e+00 7.99500373e+00 8.27499371e+00 1.30992002 0.90734900 687.75 3.04812684e+00 9.19067849e+00 9.68295660e+00 1.25055778 0.88587289 688.00 4.37931590e+00 1.03165945e+01 1.12076104e+01 1.16935570 0.92729108 688.25 5.22509531e+00 1.12059138e+01 1.23642277e+01 1.13448660 0.88823550 688.50 6.30085068e+00 1.27435543e+01 1.42161491e+01 1.11161116 0.89803874 688.75 7.69080455e+00 1.31070342e+01 1.51968030e+01 1.04016213 0.81525234 689.00 1.10372383e+01 1.39527110e+01 1.77904124e+01 0.90153895 0.81228017 689.25 1.59018993e+01 1.49231255e+01 2.18075693e+01 0.75365626 0.76204215 689.50 2.03471691e+01 1.21738195e+01 2.37109505e+01 0.53917248 0.70455166 689.75 2.20238879e+01 3.03814043e+00 2.22324523e+01 0.13708234 0.63100624 690.00 2.31236823e+01 -1.29698255e+00 2.31600269e+01 -0.05603022 0.65211420 690.25 1.00519882e+01 -1.03768510e+01 1.44471971e+01 -0.80129899 0.38508515 690.50 6.83760449e+00 -1.22009006e+01 1.39862364e+01 -1.05998984 0.59083173 690.75 5.92917896e+00 -7.41757412e+00 9.49608177e+00 -0.89645670 0.73985229 691.00 6.11313614e+00 -5.95725661e+00 8.53576826e+00 -0.77248468 0.81593898 691.25 6.69717045e+00 -4.07301080e+00 7.83846343e+00 -0.54640440 0.79707721 691.50 7.07899688e+00 -2.77045205e+00 7.60181567e+00 -0.37303792 0.78383275 691.75 7.89099396e+00 -7.33468611e-01 7.92500864e+00 -0.09268378 0.90214574 692.00 8.32633312e+00 -2.68858949e-01 8.33067274e+00 -0.03227898 0.92372355 692.25 8.39537150e+00 8.36984070e-01 8.43699028e+00 0.09936755 0.83302368 692.50 8.68065966e+00 1.28731375e+00 8.77559279e+00 0.14722378 0.83612618 692.75 9.26474595e+00 1.27795069e+00 9.35246895e+00 0.13707197 0.82687504 693.00 1.06745685e+01 1.89619826e+00 1.08416779e+01 0.17580315 0.81124623 693.25 1.22628224e+01 2.03722240e+00 1.24308925e+01 0.16462645 0.75875316 693.50 1.19730108e+01 3.51055945e+00 1.24770596e+01 0.28521224 0.69722422 693.75 1.23971463e+01 4.40458036e+00 1.31563508e+01 0.34137959 0.61249432 694.00 1.36473418e+01 2.65283450e+00 1.39027864e+01 0.19199045 0.54395855 694.25 1.63453329e+01 -4.83451695e-01 1.63524809e+01 -0.02956873 0.54794095 694.50 1.48132710e+01 -2.80491213e+00 1.50764894e+01 -0.18713577 0.51482111 694.75 1.20510565e+01 -8.67514793e+00 1.48487762e+01 -0.62393491 0.45140757 695.00 1.13173097e+01 -8.74722600e+00 1.43036870e+01 -0.65800102 0.45696770 695.25 9.55326242e+00 -1.00478852e+01 1.38645165e+01 -0.81062719 0.46448454 695.50 7.99161644e+00 -9.48586735e+00 1.24035323e+01 -0.87068653 0.43317806 695.75 4.66984357e+00 -9.11986674e+00 1.02459459e+01 -1.09755388 0.60171549 696.00 4.59763579e+00 -8.04515500e+00 9.26621680e+00 -1.05161232 0.62990376 696.25 5.88353406e+00 -6.75715819e+00 8.95964061e+00 -0.85440049 0.68035809 696.50 5.97512311e+00 -5.06000739e+00 7.82980019e+00 -0.70265999 0.67117957 696.75 5.41934092e+00 -3.46683838e+00 6.43336804e+00 -0.56911159 0.77575414 697.00 5.63458254e+00 -1.83069341e+00 5.92452181e+00 -0.31414427 0.74328789 697.25 7.42790430e+00 -2.03689768e-01 7.43069659e+00 -0.02741537 0.81135371 697.50 8.65163080e+00 -3.45329296e-01 8.65851996e+00 -0.03989376 0.84128833 697.75 9.51469420e+00 -7.31969790e-01 9.54280805e+00 -0.07677923 0.84607513 698.00 9.80391592e+00 -1.06492896e+00 9.86158410e+00 -0.10819860 0.76429670 698.25 1.07274553e+01 -1.78336260e+00 1.08746807e+01 -0.16473627 0.76466681 698.50 1.04113747e+01 -2.77065133e+00 1.07737288e+01 -0.26008982 0.74527530 698.75 8.96195484e+00 -4.09354141e+00 9.85259945e+00 -0.42846859 0.75958621 699.00 6.18152548e+00 -2.02038586e+00 6.50332348e+00 -0.31589756 0.57112932 699.25 4.18357036e+00 -5.93238235e-01 4.22542217e+00 -0.14086277 0.37959269 699.50 5.60964032e+00 1.76849918e+00 5.88180702e+00 0.30539798 0.59039133 699.75 6.44620529e+00 3.18910564e+00 7.19193697e+00 0.45941955 0.77772539 700.00 7.67106618e+00 3.46639402e+00 8.41790614e+00 0.42441544 0.82684388 700.25 8.68591479e+00 3.80770784e+00 9.48386813e+00 0.41314656 0.88559118 700.50 9.22058040e+00 4.17760777e+00 1.01228212e+01 0.42540755 0.86008582 700.75 9.51615743e+00 4.45908572e+00 1.05090769e+01 0.43819758 0.83674991 701.00 9.95841197e+00 4.51140615e+00 1.09326463e+01 0.42536638 0.79504475 701.25 1.08939297e+01 4.51983836e+00 1.17943480e+01 0.39328069 0.82771676 701.50 1.21869560e+01 3.76313380e+00 1.27547275e+01 0.29949566 0.86037779 701.75 1.27767673e+01 2.74397885e+00 1.30680987e+01 0.21154977 0.87289098 702.00 1.31333122e+01 1.78922488e+00 1.32546300e+01 0.13540203 0.86561868 702.25 1.31790588e+01 9.08455340e-01 1.32103324e+01 0.06882286 0.86912944 702.50 1.31061246e+01 -1.03672044e+00 1.31470640e+01 -0.07893762 0.88408871 702.75 1.30419600e+01 -1.82265789e+00 1.31687054e+01 -0.13885405 0.89562381 703.00 1.23197120e+01 -2.92107665e+00 1.26612792e+01 -0.23280673 0.85594946 703.25 1.13580802e+01 -3.48605713e+00 1.18810176e+01 -0.29779609 0.83534126 703.50 8.48468149e+00 -5.48193946e+00 1.01015583e+01 -0.57362758 0.81860967 703.75 7.58878556e+00 -5.95093932e+00 9.64382419e+00 -0.66501707 0.83986380 704.00 6.35872594e+00 -6.18848141e+00 8.87303205e+00 -0.77183068 0.86320277 704.25 5.46837678e+00 -5.89152588e+00 8.03823499e+00 -0.82263031 0.84388597 704.50 3.87923714e+00 -4.89206091e+00 6.24345584e+00 -0.90035925 0.81531407 704.75 3.29990165e+00 -4.19842828e+00 5.34005159e+00 -0.90465973 0.80240918 705.00 2.67462342e+00 -3.38446855e+00 4.31372667e+00 -0.90202027 0.83725316 705.25 2.51950572e+00 -2.86318459e+00 3.81388713e+00 -0.84916051 0.79156662 705.50 2.07069055e+00 -1.91515187e+00 2.82056130e+00 -0.74639517 0.71450965 705.75 1.84348399e+00 -1.79072699e+00 2.57004599e+00 -0.77088241 0.73453387 706.00 1.89002554e+00 -1.43139915e+00 2.37088592e+00 -0.64818461 0.82358349 706.25 1.93897332e+00 -1.18956230e+00 2.27479142e+00 -0.55028769 0.81985968 706.50 1.86583407e+00 -9.99670039e-01 2.11676096e+00 -0.49185751 0.84323437 706.75 1.75148160e+00 -8.07078428e-01 1.92848733e+00 -0.43179680 0.80608212 707.00 1.72076691e+00 -9.18663578e-01 1.95063618e+00 -0.49037404 0.84644028 707.25 1.44109850e+00 -1.04867651e+00 1.78227027e+00 -0.62907076 0.79132324 707.50 1.15889470e+00 -1.11508934e+00 1.60824786e+00 -0.76613684 0.83257882 707.75 9.90641696e-01 -1.15395323e+00 1.52084813e+00 -0.86140177 0.77963344 708.00 8.77316701e-01 -1.22424424e+00 1.50614029e+00 -0.94900352 0.84635861 708.25 7.28531767e-01 -1.23792747e+00 1.43639234e+00 -1.03886875 0.83003304 708.50 5.78185595e-01 -1.26741851e+00 1.39307152e+00 -1.14280546 0.83442739 708.75 2.50037504e-01 -1.36763813e+00 1.39030673e+00 -1.38996906 0.82419001 709.00 1.69327517e-01 -1.36831855e+00 1.37875577e+00 -1.44767366 0.84019027 709.25 -1.34013804e-01 -1.43270154e+00 1.43895567e+00 -1.66406417 0.84651762 709.50 -5.19918587e-01 -1.36966014e+00 1.46502022e+00 -1.93359095 0.87230125 709.75 -8.97675000e-01 -1.20759686e+00 1.50469617e+00 -2.21003203 0.83644430 710.00 -1.10260246e+00 -1.14911084e+00 1.59254134e+00 -2.33554277 0.89779965 710.25 -1.22756491e+00 -9.14654300e-01 1.53085208e+00 -2.50123719 0.88651082 710.50 -1.26615349e+00 -8.48394434e-01 1.52411213e+00 -2.55124688 0.90436464 710.75 -1.37835549e+00 -6.75141215e-01 1.53482231e+00 -2.68612501 0.91717308 711.00 -1.48596012e+00 -5.77437384e-01 1.59421184e+00 -2.77095626 0.95950290 711.25 -1.57680285e+00 -4.74502620e-01 1.64665114e+00 -2.84928558 0.97719818 711.50 -1.64845899e+00 -4.29624763e-01 1.70352414e+00 -2.88664202 0.98497855 711.75 -1.75467353e+00 -3.04026234e-01 1.78081755e+00 -2.97002942 0.98052486 712.00 -1.79606990e+00 -2.41235372e-01 1.81219800e+00 -3.00807878 0.98194605 712.25 -1.85711104e+00 -4.85812726e-02 1.85774637e+00 -3.11543902 0.98448909 712.50 -1.85436416e+00 1.74098209e-02 1.85444589e+00 3.13220436 0.98613097 712.75 -1.76644859e+00 1.89820428e-01 1.77661825e+00 3.03454464 0.98886643 713.00 -1.73008277e+00 2.16809178e-01 1.74361481e+00 3.01692532 0.99000047 713.25 -1.68472932e+00 2.72655094e-01 1.70664985e+00 2.98114470 0.98807220 713.50 -1.65405162e+00 3.01658869e-01 1.68133424e+00 2.96119950 0.98704490 713.75 -1.53700181e+00 3.29635534e-01 1.57195233e+00 2.93032639 0.99054259 714.00 -1.51106869e+00 3.27800064e-01 1.54621520e+00 2.92797001 0.99268509 714.25 -1.46780461e+00 2.62544441e-01 1.49110025e+00 2.96459564 0.99218200 714.50 -1.43737950e+00 2.60085096e-01 1.46072040e+00 2.96258556 0.99249437 714.75 -1.40493075e+00 2.21513842e-01 1.42228647e+00 2.98521116 0.99302843 715.00 -1.38489579e+00 1.93589977e-01 1.39836098e+00 3.00270594 0.99287072 715.25 -1.36372657e+00 1.55962714e-01 1.37261594e+00 3.02772229 0.99374621 715.50 -1.34625451e+00 1.42479527e-01 1.35377311e+00 3.03615114 0.99230905 715.75 -1.31677745e+00 1.26817828e-01 1.32287021e+00 3.04557954 0.99288666 716.00 -1.28576355e+00 1.06517500e-01 1.29016816e+00 3.05893763 0.99130891 716.25 -1.22789099e+00 6.16093413e-02 1.22943564e+00 3.09145977 0.99003977 716.50 -1.19173306e+00 3.59050079e-02 1.19227382e+00 3.11147337 0.98708559 716.75 -1.15268811e+00 9.26322656e-03 1.15272533e+00 3.13355663 0.99301978 717.00 -1.14242056e+00 -2.05220276e-02 1.14260487e+00 -3.12363095 0.99177004 717.25 -1.10708428e+00 -6.81375066e-02 1.10917912e+00 -3.08012338 0.99227639 717.50 -1.07263394e+00 -1.03108753e-01 1.07757830e+00 -3.04576041 0.98788652 717.75 -1.03540915e+00 -1.58943648e-01 1.04753768e+00 -2.98927362 0.98935130 718.00 -1.01494737e+00 -1.69520810e-01 1.02900703e+00 -2.97609609 0.98582744 718.25 -9.84241197e-01 -2.01466718e-01 1.00464898e+00 -2.93968924 0.98681275 718.50 -9.62016972e-01 -2.42928315e-01 9.92215108e-01 -2.89424384 0.97878116 718.75 -9.15421699e-01 -3.06264555e-01 9.65295222e-01 -2.81873745 0.98106253 719.00 -9.15273268e-01 -3.02218361e-01 9.63878153e-01 -2.82266954 0.97282764 719.25 -9.00970849e-01 -3.43265710e-01 9.64147198e-01 -2.77757617 0.97851033 719.50 -8.81000488e-01 -3.46605587e-01 9.46729788e-01 -2.76676919 0.97695444 719.75 -8.31406000e-01 -3.59090010e-01 9.05638764e-01 -2.73388635 0.97604575 720.00 -7.31309056e-01 -3.79250767e-01 8.23798567e-01 -2.66318259 0.95604423 720.25 -6.48048457e-01 -4.16322713e-01 7.70254116e-01 -2.57056081 0.95562265 720.50 -5.46298554e-01 -4.88800157e-01 7.33053684e-01 -2.41168617 0.91690080 720.75 -4.92758956e-01 -5.57109650e-01 7.43762429e-01 -2.29497703 0.90611397 721.00 -4.94040427e-01 -7.23884844e-01 8.76404707e-01 -2.16967017 0.90425578 721.25 -4.65772864e-01 -8.57092744e-01 9.75475439e-01 -2.06858406 0.92976591 721.50 -4.96474512e-01 -8.81397158e-01 1.01160659e+00 -2.08377908 0.95387537 721.75 -5.00614751e-01 -9.23974339e-01 1.05087759e+00 -2.06732673 0.95993422 722.00 -5.18226897e-01 -9.59981418e-01 1.09092779e+00 -2.06579806 0.96035389 722.25 -5.20375245e-01 -9.36898458e-01 1.07171317e+00 -2.07779377 0.96531110 722.50 -5.28112518e-01 -9.59488531e-01 1.09522649e+00 -2.07395461 0.95636304 722.75 -5.62645402e-01 -9.89849155e-01 1.13858298e+00 -2.08766795 0.95381888 723.00 -5.19969605e-01 -1.00334358e+00 1.13007377e+00 -2.04892674 0.94606509 723.25 -5.07125446e-01 -9.88060261e-01 1.11060312e+00 -2.04499048 0.94789538 723.50 -4.44708043e-01 -8.42225614e-01 9.52422821e-01 -2.05660421 0.91583870 723.75 -3.80620476e-01 -7.69092668e-01 8.58123231e-01 -2.03035198 0.89138820 724.00 -1.08091266e-01 -7.82373654e-01 7.89805202e-01 -1.70808533 0.78895911 724.25 5.23294093e-02 -8.10607843e-01 8.12295169e-01 -1.50633002 0.74084048 724.50 3.45058996e-01 -1.09128778e+00 1.14454127e+00 -1.26454936 0.88183938 724.75 3.61982031e-01 -1.25939832e+00 1.31038739e+00 -1.29091617 0.85874156 725.00 3.19488047e-01 -1.69156793e+00 1.72147457e+00 -1.38412431 0.84076680 725.25 1.30885976e-01 -1.69235577e+00 1.69740955e+00 -1.49361046 0.81408619 725.50 -4.03369169e-01 -1.33472475e+00 1.39434460e+00 -1.86428078 0.81829410 725.75 -4.52535310e-01 -1.27905552e+00 1.35675025e+00 -1.91085623 0.79520777 726.00 -3.49336075e-01 -1.09186208e+00 1.14638497e+00 -1.88044960 0.68855775 726.25 -2.09355700e-01 -7.48934789e-01 7.77645888e-01 -1.84337653 0.53063481 726.50 -5.02447163e-02 -6.01009263e-01 6.03105850e-01 -1.65420295 0.54732415 726.75 1.90725367e-01 -6.11223740e-01 6.40289486e-01 -1.26833191 0.55183284 727.00 5.78737613e-01 -6.30002901e-01 8.55476990e-01 -0.82778491 0.79167239 727.25 7.59405223e-01 -7.51186665e-01 1.06816558e+00 -0.77995760 0.88065150 727.50 9.93553530e-01 -9.01946374e-01 1.34188520e+00 -0.73710698 0.90633693 727.75 1.03017546e+00 -1.05998975e+00 1.47812034e+00 -0.79966128 0.87932174 728.00 1.04507975e+00 -1.23576169e+00 1.61842474e+00 -0.86880578 0.90339324 728.25 1.05268382e+00 -1.25164890e+00 1.63547186e+00 -0.87152845 0.89913955 728.50 1.23202932e+00 -1.18300020e+00 1.70803564e+00 -0.76509929 0.91797834 728.75 1.32809355e+00 -1.21766982e+00 1.80181916e+00 -0.74204985 0.92714337 729.00 1.52831824e+00 -1.26108665e+00 1.98143790e+00 -0.68988729 0.94201708 729.25 1.72420527e+00 -1.43903045e+00 2.24581666e+00 -0.69548834 0.94066514 729.50 1.98599685e+00 -1.61682459e+00 2.56091883e+00 -0.68328700 0.94801002 729.75 2.09943450e+00 -1.99204909e+00 2.89411209e+00 -0.75915811 0.96643891 730.00 2.11185042e+00 -2.18100834e+00 3.03590342e+00 -0.80150676 0.97824884 730.25 2.01035194e+00 -2.44127260e+00 3.16248744e+00 -0.88189826 0.97521246 730.50 1.89392275e+00 -2.57965591e+00 3.20024499e+00 -0.93749941 0.98293433 730.75 1.75883609e+00 -2.65733849e+00 3.18668357e+00 -0.98611571 0.97764832 731.00 1.64058242e+00 -2.65461061e+00 3.12065188e+00 -1.01723755 0.97868428 731.25 1.64211655e+00 -2.60662043e+00 3.08074939e+00 -1.00862450 0.97242514 731.50 1.68944270e+00 -2.57862720e+00 3.08278038e+00 -0.99079429 0.97342633 731.75 1.68393857e+00 -2.64420979e+00 3.13488349e+00 -1.00372812 0.97860398 732.00 1.65649090e+00 -2.65469974e+00 3.12912013e+00 -1.01292775 0.97850471 732.25 1.68099807e+00 -2.61071939e+00 3.10509424e+00 -0.99873324 0.96806257 732.50 1.71805622e+00 -2.61838640e+00 3.13171910e+00 -0.99010935 0.97074791 732.75 1.79681577e+00 -2.67090684e+00 3.21905115e+00 -0.97860349 0.97743930 733.00 1.86389384e+00 -2.68231021e+00 3.26632643e+00 -0.96351233 0.97808233 733.25 1.90871871e+00 -2.77160562e+00 3.36526445e+00 -0.96771565 0.97234754 733.50 1.96991927e+00 -2.83532043e+00 3.45248083e+00 -0.96358342 0.98005224 733.75 1.83073250e+00 -3.10855267e+00 3.60758662e+00 -1.03855329 0.97714265 734.00 1.75920525e+00 -3.22168138e+00 3.67069939e+00 -1.07098934 0.97547139 734.25 1.74743040e+00 -3.21249126e+00 3.65699509e+00 -1.07261091 0.97702558 734.50 1.67315948e+00 -3.20424711e+00 3.61478384e+00 -1.08957098 0.97518163 734.75 1.35167642e+00 -3.05473404e+00 3.34042351e+00 -1.15420876 0.96809690 735.00 1.21279286e+00 -2.94875952e+00 3.18842426e+00 -1.18059595 0.96390252 735.25 9.55752560e-01 -2.67279035e+00 2.83853329e+00 -1.22737938 0.94626670 735.50 9.43757503e-01 -2.48770937e+00 2.66070971e+00 -1.20820163 0.92242687 735.75 1.02843975e+00 -1.95800264e+00 2.21166513e+00 -1.08715382 0.85762537 736.00 1.07614938e+00 -1.61219799e+00 1.93837041e+00 -0.98221393 0.80832286 736.25 1.35386527e+00 -1.08898310e+00 1.73747961e+00 -0.67738846 0.79290888 736.50 1.67210694e+00 -7.53045834e-01 1.83385377e+00 -0.42315115 0.69871407 736.75 2.36463117e+00 -1.25957239e-01 2.36798349e+00 -0.05321689 0.70831284 737.00 3.10543957e+00 -4.08608057e-02 3.10570838e+00 -0.01315706 0.76822961 737.25 4.34529411e+00 -9.43806764e-02 4.34631898e+00 -0.02171679 0.81423480 737.50 4.98381942e+00 -9.43915584e-01 5.07241881e+00 -0.18717895 0.82461636 737.75 6.16603700e+00 -1.79501322e+00 6.42200006e+00 -0.28328373 0.84012679 738.00 6.28778194e+00 -2.26159807e+00 6.68214244e+00 -0.34527349 0.76243845 738.25 5.83082563e+00 -3.25028168e+00 6.67554182e+00 -0.50853032 0.76254622 738.50 5.39580206e+00 -4.07987401e+00 6.76461764e+00 -0.64740644 0.74947937 738.75 4.60230616e+00 -5.10656465e+00 6.87446176e+00 -0.83728945 0.85881729 739.00 4.01300458e+00 -5.01331319e+00 6.42164425e+00 -0.89576914 0.79139819 739.25 3.64815295e+00 -5.20932248e+00 6.35972174e+00 -0.95986075 0.74652518 739.50 3.29184168e+00 -4.76809512e+00 5.79404459e+00 -0.96654969 0.67971042 739.75 3.46248779e+00 -4.82555703e+00 5.93926110e+00 -0.94840109 0.70802520 740.00 3.02255175e+00 -4.95171220e+00 5.80131647e+00 -1.02276092 0.65726245 740.25 2.57666460e+00 -4.84368560e+00 5.48639141e+00 -1.08190598 0.64580685 740.50 1.61097557e+00 -4.15080984e+00 4.45246725e+00 -1.20058079 0.60452135 740.75 9.63500135e-01 -4.50651628e+00 4.60836430e+00 -1.36016595 0.60428961 741.00 5.00088218e-01 -4.57667369e+00 4.60391467e+00 -1.46195919 0.58931773 741.25 3.17005163e-01 -4.37698264e+00 4.38844725e+00 -1.49849706 0.47748010 741.50 -4.33507150e-01 -2.52131805e+00 2.55831452e+00 -1.74106820 0.24169225 741.75 -1.02583151e+00 -2.18343232e+00 2.41240688e+00 -2.01001402 0.32430906 742.00 -7.57603497e-01 -1.82174568e+00 1.97299781e+00 -1.96490569 0.25563782 742.25 -4.47277352e-01 -1.17620832e+00 1.25838112e+00 -1.93417970 0.16532419 742.50 9.58129082e-01 -6.13262386e-01 1.13758608e+00 -0.56935745 0.25433047 742.75 1.56216563e+00 -5.03957608e-01 1.64144288e+00 -0.31206138 0.40628143 743.00 2.30733447e+00 -4.70748571e-01 2.35486657e+00 -0.20126052 0.57699180 743.25 2.38347638e+00 -4.37541392e-01 2.42330397e+00 -0.18155143 0.61158965 743.50 2.86608065e+00 -6.85949623e-01 2.94702311e+00 -0.23491485 0.55836402 743.75 2.93792877e+00 -6.95823456e-01 3.01920449e+00 -0.23255637 0.56111923 744.00 2.24998061e+00 -1.35298129e+00 2.62544684e+00 -0.54139702 0.41158826 744.25 1.91858546e+00 -1.25807781e+00 2.29428201e+00 -0.58039417 0.29242053 744.50 2.11594923e+00 -9.30000984e-01 2.31130764e+00 -0.41410425 0.19579792 744.75 1.02615673e+00 3.31437551e-01 1.07835452e+00 0.31241214 0.03619863 745.00 8.81400465e-01 1.87685961e+00 2.07351604e+00 1.13175125 0.12011820 745.25 -3.62420619e-01 1.29186097e+00 1.34173524e+00 1.84430710 0.05977463 745.50 -1.33892998e+00 1.16511398e+00 1.77488706e+00 2.42549744 0.26273324 745.75 -1.00850895e+00 1.17232890e+00 1.54642988e+00 2.28121741 0.36185416 746.00 -6.84903229e-01 6.28004888e-01 9.29237630e-01 2.39950503 0.28978017 746.25 -3.44867688e-01 2.71319619e-01 4.38802983e-01 2.47499238 0.09393238 746.50 5.12301580e-01 -6.88958349e-02 5.16913480e-01 -0.13368091 0.19483901 746.75 6.19970815e-01 -2.63910154e-01 6.73804408e-01 -0.40244781 0.32115208 747.00 8.12269546e-01 -3.47257053e-01 8.83385123e-01 -0.40399857 0.59347719 747.25 9.16935782e-01 -3.93390259e-01 9.97761056e-01 -0.40527665 0.63582177 747.50 9.93600660e-01 -6.66038853e-01 1.19618143e+00 -0.59053344 0.76139465 747.75 9.69154097e-01 -7.05450662e-01 1.19871610e+00 -0.62920872 0.79316189 748.00 9.27787849e-01 -6.39180320e-01 1.12665069e+00 -0.60325732 0.85744334 748.25 9.39670304e-01 -6.35075270e-01 1.13415205e+00 -0.59433272 0.88104065 748.50 9.59781813e-01 -6.31887799e-01 1.14911415e+00 -0.58223401 0.87103089 748.75 1.03218606e+00 -5.11012674e-01 1.15175606e+00 -0.45970231 0.88016678 749.00 1.10851253e+00 -5.25209553e-01 1.22663976e+00 -0.44246608 0.90424712 749.25 1.15281610e+00 -4.62131826e-01 1.24199468e+00 -0.38125797 0.89262814 749.50 1.20766553e+00 -3.67374166e-01 1.26230734e+00 -0.29530729 0.89744695 749.75 1.32245699e+00 -3.57993999e-01 1.37005554e+00 -0.26436760 0.92504490 750.00 1.35129469e+00 -2.61040671e-01 1.37627743e+00 -0.19082761 0.94281454 750.25 1.34825440e+00 -2.53455391e-01 1.37187083e+00 -0.18581915 0.92678131 750.50 1.40394946e+00 -2.44483970e-01 1.42507771e+00 -0.17241125 0.93689104 750.75 1.52856178e+00 -3.11348329e-01 1.55994836e+00 -0.20093833 0.94509821 751.00 1.65618608e+00 -3.11207202e-01 1.68517128e+00 -0.18574007 0.95441850 751.25 1.83005904e+00 -2.37046958e-01 1.84534749e+00 -0.12881247 0.92537055 751.50 1.90941543e+00 -2.87575467e-01 1.93094975e+00 -0.14948566 0.90629559 751.75 1.99069811e+00 -3.02477347e-01 2.01354700e+00 -0.15079196 0.89954384 752.00 2.10769391e+00 -3.57624782e-01 2.13781878e+00 -0.16807511 0.91258825 752.25 2.04940722e+00 -5.77993032e-01 2.12935340e+00 -0.27488955 0.87574009 752.50 1.82818794e+00 -7.31489994e-01 1.96909846e+00 -0.38060767 0.82236949 752.75 1.48011467e+00 -9.48794224e-01 1.75810976e+00 -0.57004179 0.77832773 753.00 1.34632706e+00 -9.72049724e-01 1.66056533e+00 -0.62533976 0.78460368 753.25 1.12694067e+00 -8.49410971e-01 1.41120313e+00 -0.64588516 0.74061254 753.50 9.02493630e-01 -7.59906292e-01 1.17981029e+00 -0.69983559 0.69082643 753.75 9.29460716e-01 -7.03038712e-01 1.16540150e+00 -0.64758086 0.72831472 754.00 9.76979235e-01 -7.43178537e-01 1.22751895e+00 -0.65030781 0.72329170 754.25 8.23176550e-01 -6.12486971e-01 1.02604090e+00 -0.63968414 0.67035150 754.50 6.96227996e-01 -4.99658534e-01 8.56966786e-01 -0.62248361 0.62218565 754.75 5.87932749e-01 -4.85237530e-01 7.62312519e-01 -0.68999535 0.47188513 755.00 5.99838134e-01 -6.11000388e-01 8.56228510e-01 -0.79461652 0.51359982 755.25 4.81565847e-01 -6.31719999e-01 7.94339866e-01 -0.91946388 0.39477108 755.50 4.80052009e-01 -7.00547844e-01 8.49245084e-01 -0.97003688 0.36016191 755.75 9.15087264e-01 -1.00516852e+00 1.35931911e+00 -0.83227487 0.54791726 756.00 1.08046234e+00 -1.00312768e+00 1.47433511e+00 -0.74829913 0.66528978 756.25 1.16026798e+00 -7.89343828e-01 1.40331232e+00 -0.59738974 0.79231095 756.50 1.13919712e+00 -7.42466395e-01 1.35978911e+00 -0.57760118 0.78752431 756.75 1.07282911e+00 -7.86398185e-01 1.33018209e+00 -0.63254080 0.81867427 757.00 1.06200782e+00 -7.53982697e-01 1.30244021e+00 -0.61737906 0.86506894 757.25 1.08992554e+00 -6.94079060e-01 1.29216230e+00 -0.56704920 0.88213776 757.50 1.10620506e+00 -6.84188790e-01 1.30069364e+00 -0.55391212 0.87787381 757.75 9.48872134e-01 -6.31094525e-01 1.13957827e+00 -0.58691696 0.78808749 758.00 8.28762445e-01 -5.86657429e-01 1.01538866e+00 -0.61598943 0.78791639 758.25 8.45155625e-01 -6.12675225e-01 1.04386731e+00 -0.62725964 0.88345047 758.50 8.67577425e-01 -5.85786328e-01 1.04682196e+00 -0.59388551 0.88260675 758.75 9.19545720e-01 -6.22966916e-01 1.11069893e+00 -0.59544629 0.87893170 759.00 8.15285124e-01 -6.50485241e-01 1.04298652e+00 -0.67343609 0.86464692 759.25 6.75454879e-01 -7.86186183e-01 1.03649795e+00 -0.86101193 0.87585533 759.50 5.24554365e-01 -8.02553535e-01 9.58774978e-01 -0.99188982 0.87392804 759.75 3.94073165e-01 -6.80393315e-01 7.86275220e-01 -1.04582308 0.89289909 760.00 2.98005944e-01 -5.43961354e-01 6.20243095e-01 -1.06960993 0.82370651 760.25 2.25705001e-01 -4.55622744e-01 5.08463207e-01 -1.11085400 0.82299191 760.50 2.11420499e-01 -3.53087477e-01 4.11545130e-01 -1.03127691 0.79164622 760.75 2.07436830e-01 -2.48652485e-01 3.23818000e-01 -0.87552088 0.78825705 761.00 2.28035035e-01 -1.45576977e-01 2.70541371e-01 -0.56817546 0.76045017 761.25 2.51265016e-01 -1.05517993e-01 2.72521843e-01 -0.39758295 0.75813672 761.50 2.69097512e-01 -7.01611428e-02 2.78093612e-01 -0.25504945 0.66854276 761.75 2.76193697e-01 -5.04434117e-02 2.80762348e-01 -0.18064678 0.66396969 762.00 2.31341818e-01 -1.39187164e-02 2.31760151e-01 -0.06009272 0.61700984 762.25 2.02381408e-01 3.59433604e-02 2.05548436e-01 0.17576931 0.61976599 762.50 1.93761397e-01 1.41282763e-01 2.39800538e-01 0.63002855 0.67374783 762.75 2.18346775e-01 2.04093951e-01 2.98880670e-01 0.75167173 0.77506815 763.00 2.48801231e-01 3.17938975e-01 4.03716787e-01 0.90679030 0.82545695 763.25 3.00172654e-01 3.87368989e-01 4.90059544e-01 0.91154805 0.88819828 763.50 4.15172017e-01 4.46757602e-01 6.09885365e-01 0.82202698 0.90247107 763.75 4.65026244e-01 5.15792406e-01 6.94471896e-01 0.83711099 0.91393562 764.00 5.58059010e-01 5.67982679e-01 7.96262634e-01 0.79421081 0.90786179 764.25 6.39377352e-01 5.22666500e-01 8.25823025e-01 0.68529800 0.89388782 764.50 8.58250148e-01 4.26336644e-01 9.58309058e-01 0.46104506 0.93092115 764.75 9.52579505e-01 4.07964553e-01 1.03626386e+00 0.40464006 0.96705699 765.00 1.01405448e+00 3.16434069e-01 1.06227916e+00 0.30247338 0.96060391 765.25 1.04705975e+00 2.16147895e-01 1.06913705e+00 0.20357361 0.95475066 765.50 1.04491144e+00 6.89848506e-02 1.04718614e+00 0.06592414 0.91181529 765.75 1.02241911e+00 -6.11602553e-02 1.02424675e+00 -0.05974796 0.89931156 766.00 9.10262048e-01 -3.02825350e-01 9.59312352e-01 -0.32116182 0.90893494 766.25 8.06326429e-01 -3.74767308e-01 8.89164127e-01 -0.43507974 0.91805961 766.50 6.42103411e-01 -3.56125124e-01 7.34249205e-01 -0.50638538 0.88666744 766.75 5.46142557e-01 -2.85040946e-01 6.16051973e-01 -0.48102688 0.85515210 767.00 4.47737717e-01 -2.36683791e-01 5.06446720e-01 -0.48628178 0.86724805 767.25 4.21265245e-01 -1.78006907e-01 4.57330149e-01 -0.39979622 0.84919671 767.50 4.30400819e-01 -8.51618877e-02 4.38745270e-01 -0.19534324 0.85634877 767.75 4.57265023e-01 -3.95751534e-02 4.58974393e-01 -0.08633239 0.83034937 768.00 5.20245289e-01 4.55463995e-02 5.22235230e-01 0.08732528 0.85890756 768.25 5.74220138e-01 4.05757455e-02 5.75651942e-01 0.07054509 0.85348762 768.50 6.96486362e-01 -9.54661161e-02 7.02998600e-01 -0.13621933 0.91310876 768.75 6.92281094e-01 -1.43429394e-01 7.06983100e-01 -0.20429337 0.91333916 769.00 6.86241955e-01 -2.09492728e-01 7.17506253e-01 -0.29628948 0.91052838 769.25 6.67399712e-01 -2.75575835e-01 7.22055687e-01 -0.39158568 0.89113701 769.50 5.97236274e-01 -3.72009785e-01 7.03620954e-01 -0.55707729 0.89418219 769.75 5.51772626e-01 -4.17182310e-01 6.91732687e-01 -0.64737873 0.85993736 770.00 4.87315308e-01 -4.60216179e-01 6.70279897e-01 -0.75680624 0.80013827 770.25 4.13910860e-01 -4.07076074e-01 5.80545545e-01 -0.77707327 0.74021236 770.50 3.81983369e-01 -3.65011888e-01 5.28341719e-01 -0.76268241 0.66466331 770.75 3.13216209e-01 -3.43018638e-01 4.64506382e-01 -0.83078125 0.55409922 771.00 2.35062161e-01 -3.26342118e-01 4.02185776e-01 -0.94657989 0.46854526 771.25 3.26387545e-01 -2.86746863e-01 4.34456664e-01 -0.72083550 0.41214970 771.50 3.75448276e-01 -3.46897797e-01 5.11174617e-01 -0.74589407 0.40841227 771.75 3.78288559e-01 -4.32219376e-01 5.74382994e-01 -0.85183975 0.48317214 772.00 3.47966850e-01 -5.18946692e-01 6.24809249e-01 -0.98012717 0.54621690 772.25 2.68354263e-01 -5.90172849e-01 6.48319367e-01 -1.14403701 0.59495166 772.50 2.65714138e-01 -7.59360975e-01 8.04507982e-01 -1.23419448 0.63944728 772.75 -5.14658260e-02 -6.27041660e-01 6.29150200e-01 -1.65268996 0.52561671 773.00 -2.48489619e-01 -5.52227108e-01 6.05559138e-01 -1.99363131 0.52461879 773.25 -3.23588253e-01 -4.43090470e-01 5.48669775e-01 -2.20156871 0.45590212 773.50 -2.84376695e-01 -2.74098353e-01 3.94968369e-01 -2.37459671 0.27651771 773.75 -2.66809242e-01 -1.09315189e-01 2.88334844e-01 -2.75274123 0.18314776 774.00 -3.01644059e-01 -2.25384118e-02 3.02484906e-01 -3.06701267 0.25269049 774.25 -1.49943857e-01 1.45643653e-01 2.09034050e-01 2.37074145 0.17311091 774.50 -4.28817575e-02 1.63105644e-01 1.68648440e-01 1.82788620 0.13378371 774.75 1.06866581e-01 1.23919009e-01 1.63634920e-01 0.85915275 0.20050617 775.00 1.61029691e-01 7.02603700e-02 1.75690298e-01 0.41141904 0.27875888 775.25 2.22845963e-01 1.78265934e-02 2.23557847e-01 0.07982515 0.41215724 775.50 2.33355881e-01 -7.40059336e-03 2.33473201e-01 -0.03170314 0.50814516 775.75 2.63990680e-01 -8.32854119e-02 2.76816797e-01 -0.30560306 0.75632310 776.00 2.64062627e-01 -1.15796459e-01 2.88336420e-01 -0.41326535 0.80099403 776.25 2.34599248e-01 -1.74049870e-01 2.92113273e-01 -0.63829881 0.81177045 776.50 1.76680386e-01 -2.25124781e-01 2.86176739e-01 -0.90538588 0.80597198 776.75 1.04265191e-01 -2.57837432e-01 2.78121145e-01 -1.18651683 0.87120318 777.00 8.11660324e-02 -2.60165688e-01 2.72532769e-01 -1.26838687 0.87794502 777.25 2.07751278e-02 -2.31975563e-01 2.32903988e-01 -1.48147722 0.84312101 777.50 -6.73590481e-04 -2.18391439e-01 2.18392478e-01 -1.57388064 0.83065376 777.75 -2.67860667e-02 -1.86944915e-01 1.88854163e-01 -1.71311090 0.83477141 778.00 -4.50039881e-02 -1.74173112e-01 1.79893390e-01 -1.82365250 0.76996805 778.25 -6.06473929e-02 -1.44549793e-01 1.56756974e-01 -1.96805072 0.79048657 778.50 -5.08498226e-02 -1.27057580e-01 1.36855153e-01 -1.95148446 0.71595048 778.75 -3.91970918e-02 -1.12596909e-01 1.19224477e-01 -1.90579419 0.73143250 779.00 -2.33784789e-02 -9.88382184e-02 1.01565480e-01 -1.80306036 0.62456112 779.25 -1.12382412e-02 -8.84742595e-02 8.91851595e-02 -1.69714243 0.63889713 779.50 -1.18831475e-02 -8.80989974e-02 8.88968084e-02 -1.70487116 0.60956112 779.75 -1.29173930e-02 -9.41764100e-02 9.50581677e-02 -1.70710741 0.66146200 780.00 -1.74409618e-02 -8.63324376e-02 8.80765402e-02 -1.77013436 0.54063205 780.25 -1.54966924e-02 -6.05376372e-02 6.24896231e-02 -1.82139941 0.41914521 780.50 -5.01742846e-03 -4.72022982e-02 4.74682162e-02 -1.67669495 0.25311728 780.75 1.84062056e-02 -2.24640851e-02 2.90417548e-02 -0.88436061 0.12459182 781.00 6.02897320e-02 -2.84536672e-02 6.66668056e-02 -0.44095590 0.39295391 781.25 1.05789728e-01 -4.60109337e-02 1.15362353e-01 -0.41024976 0.64473359 781.50 1.38814099e-01 -8.35621247e-02 1.62024636e-01 -0.54186784 0.75283381 781.75 1.44264194e-01 -1.38564408e-01 2.00030629e-01 -0.76524810 0.82258244 782.00 1.01076793e-01 -1.62735527e-01 1.91570796e-01 -1.01499863 0.76734481 782.25 6.57275708e-02 -1.84426498e-01 1.95788781e-01 -1.22844115 0.78670027 782.50 -7.91338526e-03 -1.99648780e-01 1.99805548e-01 -1.61041212 0.73988455 782.75 -5.40168488e-02 -1.92396519e-01 1.99835534e-01 -1.84450772 0.71709694 783.00 -7.95867886e-02 -1.47280694e-01 1.67408661e-01 -2.06621980 0.43750029 783.25 -9.17073211e-02 -8.91182548e-02 1.27876097e-01 -2.37051154 0.28860607 783.50 -8.14007873e-02 5.16859164e-03 8.15647137e-02 3.07818218 0.15075485 783.75 -8.05879316e-02 5.72024287e-02 9.88257687e-02 2.52431055 0.21453035 784.00 2.92857227e-02 1.34726204e-01 1.37872418e-01 1.35675395 0.29154232 784.25 1.35816326e-01 2.02565187e-01 2.43882614e-01 0.98015694 0.62986245 784.50 2.20268605e-01 1.95162615e-01 2.94290171e-01 0.72503801 0.64850674 784.75 2.89768183e-01 1.74718204e-01 3.38366740e-01 0.54259207 0.73225467 785.00 4.45621039e-01 1.11571097e-01 4.59375902e-01 0.24532889 0.81080834 785.25 5.06167136e-01 5.09544851e-02 5.08725397e-01 0.10032931 0.81116186 785.50 5.90122755e-01 -1.65336604e-01 6.12846684e-01 -0.27316934 0.86090093 785.75 6.11808252e-01 -2.47732673e-01 6.60061220e-01 -0.38473953 0.88926285 786.00 5.35459143e-01 -4.52839301e-01 7.01270223e-01 -0.70199403 0.89137358 786.25 4.26892993e-01 -5.41178845e-01 6.89283810e-01 -0.90290940 0.88455965 786.50 2.11234482e-01 -5.92484422e-01 6.29013352e-01 -1.22832199 0.89274222 786.75 1.04283205e-01 -5.67486307e-01 5.76988471e-01 -1.38906052 0.88710772 787.00 -6.51007643e-02 -4.63599569e-01 4.68148128e-01 -1.71030864 0.89473183 787.25 -8.66883184e-02 -3.76089858e-01 3.85951352e-01 -1.79733855 0.85577135 787.50 -8.14165396e-02 -2.59171721e-01 2.71659039e-01 -1.87517577 0.85469003 787.75 -5.59939220e-02 -1.99985999e-01 2.07676958e-01 -1.84379502 0.79182698 788.00 2.50801846e-03 -1.27362643e-01 1.27387334e-01 -1.55110692 0.74171462 788.25 3.33042895e-02 -1.11541651e-01 1.16407541e-01 -1.28064128 0.73679544 788.50 7.31807576e-02 -9.53155079e-02 1.20168504e-01 -0.91601664 0.76880371 788.75 1.03055954e-01 -8.91821993e-02 1.36286442e-01 -0.71335345 0.81689577 789.00 1.66505923e-01 -9.04460478e-02 1.89485382e-01 -0.49760764 0.88801084 789.25 1.93666545e-01 -8.72235865e-02 2.12402177e-01 -0.42317010 0.88003411 789.50 2.40580892e-01 -9.14331533e-02 2.57369748e-01 -0.36319210 0.90947179 789.75 2.71676430e-01 -8.86122288e-02 2.85762506e-01 -0.31528819 0.89103408 790.00 3.16418569e-01 -1.03451281e-01 3.32900703e-01 -0.31598954 0.91159325 790.25 3.50643313e-01 -1.40346865e-01 3.77687669e-01 -0.38072650 0.88381641 790.50 4.31202629e-01 -2.00809305e-01 4.75668040e-01 -0.43582972 0.92521427 790.75 4.69557081e-01 -2.33511092e-01 5.24415181e-01 -0.46148588 0.91993090 791.00 5.22369673e-01 -3.03721387e-01 6.04248919e-01 -0.52665315 0.94202769 791.25 5.54037935e-01 -3.73795155e-01 6.68341867e-01 -0.59352588 0.92105833 791.50 5.78428688e-01 -4.77662649e-01 7.50160885e-01 -0.69027200 0.90933622 791.75 5.44475054e-01 -6.13744949e-01 8.20448625e-01 -0.84513421 0.89913314 792.00 4.47641542e-01 -7.52015060e-01 8.75162614e-01 -1.03387230 0.92485129 792.25 3.29318042e-01 -8.49077340e-01 9.10704509e-01 -1.20080429 0.91787146 792.50 2.44066374e-01 -8.96029898e-01 9.28675387e-01 -1.30486156 0.92929108 792.75 6.06064680e-02 -8.82069263e-01 8.84148929e-01 -1.50219473 0.92496701 793.00 -2.78856368e-02 -8.42701092e-01 8.43162344e-01 -1.60387504 0.92927390 793.25 -1.50476263e-01 -7.59569716e-01 7.74331492e-01 -1.76637127 0.93327073 793.50 -1.97666581e-01 -6.73645272e-01 7.02047028e-01 -1.85621318 0.94761221 793.75 -1.98524402e-01 -5.61704040e-01 5.95754452e-01 -1.91052568 0.93108052 794.00 -1.86306417e-01 -5.06006464e-01 5.39214820e-01 -1.92358308 0.93071276 794.25 -1.51414939e-01 -4.84777347e-01 5.07873567e-01 -1.87353464 0.91959498 794.50 -1.29932094e-01 -4.79676595e-01 4.96962761e-01 -1.83532294 0.92672689 794.75 -1.45576535e-01 -4.34542350e-01 4.58278934e-01 -1.89405616 0.90648276 795.00 -1.56709823e-01 -4.14421864e-01 4.43061452e-01 -1.93231774 0.87594887 795.25 -1.61233257e-01 -3.96687767e-01 4.28202461e-01 -1.95684960 0.86436274 795.50 -1.59417190e-01 -3.59489830e-01 3.93251546e-01 -1.98819325 0.84403349 795.75 -1.42002791e-01 -3.03541502e-01 3.35115258e-01 -2.00837016 0.76797654 796.00 -1.58937525e-01 -2.94885088e-01 3.34990078e-01 -2.06514048 0.77652280 796.25 -1.39410785e-01 -2.43766640e-01 2.80815850e-01 -2.09029974 0.72300569 796.50 -1.25818323e-01 -2.20803753e-01 2.54134901e-01 -2.08872874 0.68370332 796.75 -1.46622162e-01 -1.90196980e-01 2.40151930e-01 -2.22753753 0.67681637 797.00 -1.18257746e-01 -1.60067016e-01 1.99013427e-01 -2.20709176 0.64049463 797.25 -1.14724403e-01 -6.57611200e-02 1.32235448e-01 -2.62110501 0.24913577 797.50 -7.13956770e-02 1.21320951e-02 7.24191303e-02 2.97327288 0.08669895 797.75 1.72769599e-02 3.70774341e-02 4.09051276e-02 1.13474167 0.03956688 798.00 3.51104510e-02 3.45105360e-02 4.92312996e-02 0.77678151 0.06432311 798.25 6.32050838e-02 7.80130582e-02 1.00403784e-01 0.88987523 0.15145276 798.50 9.59245811e-02 9.89047879e-02 1.37781284e-01 0.80069347 0.20302937 798.75 1.68507659e-01 9.07144408e-02 1.91373825e-01 0.49384727 0.25222942 799.00 1.49359474e-01 1.47408411e-01 2.09851119e-01 0.77882389 0.24177319 799.25 2.20847389e-01 1.81508437e-01 2.85865146e-01 0.68793638 0.48727146 799.50 2.03089293e-01 2.13943692e-01 2.94986719e-01 0.81141996 0.44309701 799.75 2.12455846e-01 3.40331403e-01 4.01201882e-01 1.01272813 0.63172926 800.00 2.52063120e-01 3.77998587e-01 4.54333301e-01 0.98267640 0.61747427 800.25 2.97678852e-01 5.07897887e-01 5.88704478e-01 1.04066026 0.58343980 800.50 4.20251734e-01 6.54107872e-01 7.77475806e-01 0.99972520 0.59170894 800.75 6.79221122e-01 8.05341611e-01 1.05352572e+00 0.87014930 0.60574867 801.00 9.25989534e-01 9.02009880e-01 1.29270199e+00 0.77228094 0.57384343 801.25 1.50577831e+00 8.98204352e-01 1.75332238e+00 0.53784572 0.54908765 801.50 1.96097739e+00 7.01789393e-02 1.96223276e+00 0.03577247 0.54645368 801.75 1.91367259e+00 -2.56112561e-01 1.93073468e+00 -0.13304245 0.59363977 802.00 1.85112229e+00 -7.65190471e-01 2.00304024e+00 -0.39197517 0.54299952 802.25 1.36126264e+00 -1.49868656e+00 2.02462278e+00 -0.83341241 0.46688563 802.50 1.24381292e+00 -2.29990818e+00 2.61469849e+00 -1.07503629 0.56629706 802.75 1.47610092e+00 -2.72451922e+00 3.09868987e+00 -1.07428286 0.66163764 803.00 6.54112336e-01 -2.56836079e+00 2.65034717e+00 -1.32141702 0.67371928 803.25 6.42844128e-01 -2.32168159e+00 2.40903590e+00 -1.30067636 0.76793672 803.50 1.03983165e+00 -2.73938051e+00 2.93009478e+00 -1.20801076 0.80837074 803.75 1.15680511e+00 -2.97243564e+00 3.18960369e+00 -1.19965435 0.72701590 804.00 4.82918972e-01 -3.14217372e+00 3.17906691e+00 -1.41830008 0.63749293 804.25 -3.15465146e-02 -3.26794645e+00 3.26809871e+00 -1.58044934 0.70746702 804.50 -3.69414450e-01 -3.28535057e+00 3.30605435e+00 -1.68276893 0.79110449 804.75 -7.62373254e-01 -3.24893654e+00 3.33718468e+00 -1.80127958 0.79351873 805.00 -1.36219914e+00 -3.11316162e+00 3.39814092e+00 -1.98325824 0.81361265 805.25 -1.55488185e+00 -2.77487720e+00 3.18081767e+00 -2.08154541 0.81082109 805.50 -2.01684701e+00 -2.36570532e+00 3.10873503e+00 -2.27676035 0.82806452 805.75 -2.35133545e+00 -2.23513666e+00 3.24416620e+00 -2.38152418 0.88303073 806.00 -2.58011144e+00 -1.89482239e+00 3.20114463e+00 -2.50815341 0.89568047 806.25 -2.75034146e+00 -1.72251314e+00 3.24521643e+00 -2.58206577 0.89903803 806.50 -3.06837811e+00 -1.38076632e+00 3.36473771e+00 -2.71873977 0.89152648 806.75 -3.06886056e+00 -1.09354236e+00 3.25787355e+00 -2.79928539 0.89262189 807.00 -2.95245560e+00 -5.85168812e-01 3.00988648e+00 -2.94593103 0.87602919 807.25 -2.84067389e+00 -4.23783549e-01 2.87211083e+00 -2.99350069 0.86296938 807.50 -3.00958289e+00 -7.27827784e-03 3.00959170e+00 -3.13917429 0.87154248 807.75 -2.92784837e+00 1.75882016e-01 2.93312641e+00 3.08159265 0.87148651 808.00 -3.11706605e+00 2.63631447e-01 3.12819473e+00 3.05721667 0.82099841 808.25 -3.18666305e+00 4.11694009e-01 3.21314696e+00 3.01311149 0.82760201 808.50 -3.22344624e+00 1.06323571e+00 3.39427103e+00 2.82298541 0.84811535 808.75 -3.12020049e+00 1.68088842e+00 3.54415533e+00 2.64745740 0.84553349 809.00 -2.77586394e+00 2.40733009e+00 3.67432426e+00 2.42717672 0.84440207 809.25 -2.30757107e+00 2.99377620e+00 3.77989155e+00 2.22747045 0.76510071 809.50 -1.56083298e+00 4.01025290e+00 4.30329268e+00 1.94196704 0.83191068 809.75 -1.22548477e+00 3.87419400e+00 4.06339662e+00 1.87715748 0.79741721 810.00 -1.63640012e-01 3.82727673e+00 3.83077344e+00 1.61352655 0.70653236 810.25 6.27693921e-01 3.43913590e+00 3.49594843e+00 1.39026838 0.65077903 810.50 1.50685019e+00 3.41049227e+00 3.72854597e+00 1.15475918 0.69542626 810.75 2.38330426e+00 3.10976243e+00 3.91800479e+00 0.91688515 0.67157246 811.00 3.82266121e+00 3.22432888e+00 5.00090347e+00 0.70069523 0.80759534 811.25 3.44106680e+00 2.21529551e+00 4.09249006e+00 0.57199134 0.66288004 811.50 4.26552870e+00 9.99402694e-01 4.38104335e+00 0.23014612 0.74462199 811.75 3.95114848e+00 3.71439507e-01 3.96856921e+00 0.09373251 0.73293786 812.00 3.82482206e+00 -6.26119466e-02 3.82533450e+00 -0.01636844 0.78358091 812.25 3.58529856e+00 -5.82389319e-01 3.63229171e+00 -0.16103166 0.74243736 812.50 3.45578375e+00 -7.42293119e-01 3.53460612e+00 -0.21158244 0.79498810 812.75 3.09386722e+00 -8.62303451e-01 3.21178792e+00 -0.27181560 0.75956520 813.00 2.88178455e+00 -1.26036349e+00 3.14534550e+00 -0.41228891 0.76370129 813.25 2.50765200e+00 -1.24957731e+00 2.80174267e+00 -0.46229126 0.80940074 813.50 2.33694484e+00 -1.25632845e+00 2.65323809e+00 -0.49326889 0.82376510 813.75 2.50242854e+00 -1.36772035e+00 2.85180777e+00 -0.50019615 0.78659455 814.00 2.66011208e+00 -1.35612909e+00 2.98584702e+00 -0.47145802 0.84262917 814.25 2.92718026e+00 -1.36828742e+00 3.23119092e+00 -0.43726377 0.83512514 814.50 3.25405400e+00 -1.77940544e+00 3.70879376e+00 -0.50040407 0.83407381 814.75 2.57279251e+00 -2.54483675e+00 3.61876435e+00 -0.77993558 0.70394419 815.00 2.40518950e+00 -2.97066991e+00 3.82227893e+00 -0.89020160 0.76021502 815.25 2.17455377e+00 -3.63229403e+00 4.23346713e+00 -1.03135366 0.77327928 815.50 1.69189522e+00 -3.91903699e+00 4.26864854e+00 -1.16325434 0.79318431 815.75 9.65173592e-01 -3.78140754e+00 3.90264053e+00 -1.32089024 0.80651143 816.00 8.90416706e-01 -3.84783468e+00 3.94951562e+00 -1.34339184 0.80873970 816.25 7.70009448e-02 -3.94441106e+00 3.94516258e+00 -1.55127727 0.71553105 816.50 -5.01249504e-01 -3.80520046e+00 3.83807264e+00 -1.70176973 0.73149576 816.75 -9.78222435e-01 -2.71451779e+00 2.88539875e+00 -1.91667670 0.60805238 817.00 -9.56384305e-01 -2.49099516e+00 2.66828181e+00 -1.93737875 0.61839863 817.25 -1.18829736e+00 -2.03903085e+00 2.36002063e+00 -2.09845452 0.66985904 817.50 -1.24596803e+00 -1.78051362e+00 2.17316937e+00 -2.18137470 0.65503198 817.75 -8.00475907e-01 -1.68450744e+00 1.86502735e+00 -2.01440685 0.57217572 818.00 -5.45743548e-01 -1.73735237e+00 1.82105169e+00 -1.87515975 0.65347949 818.25 -3.29345489e-01 -1.56013947e+00 1.59452301e+00 -1.77884185 0.66110779 818.50 -4.47387873e-01 -1.55242552e+00 1.61560543e+00 -1.85138000 0.65621804 818.75 -4.05037278e-01 -1.55975514e+00 1.61148729e+00 -1.82486466 0.59741003 819.00 -2.83975591e-01 -1.42566111e+00 1.45366838e+00 -1.76741167 0.63069793 819.25 -2.55069065e-01 -1.18127080e+00 1.20849532e+00 -1.78345901 0.62516226 819.50 -2.20020773e-01 -1.09286606e+00 1.11479387e+00 -1.76946517 0.56792025 819.75 -2.37282635e-01 -1.02820190e+00 1.05522614e+00 -1.79760004 0.57738748 820.00 -5.02763105e-02 -9.94217662e-01 9.95488054e-01 -1.62132200 0.58902305 820.25 3.38882420e-01 -8.29350411e-01 8.95914839e-01 -1.18288804 0.58602126 820.50 5.97614347e-01 -9.57078836e-01 1.12833630e+00 -1.01261782 0.69457783 820.75 8.82218807e-01 -1.08184127e+00 1.39595507e+00 -0.88668799 0.83810846 821.00 8.70893999e-01 -1.20875779e+00 1.48981601e+00 -0.94645277 0.81040273 821.25 1.06124311e+00 -1.62149242e+00 1.93790470e+00 -0.99127439 0.88993264 821.50 1.04967478e+00 -1.92158463e+00 2.18959006e+00 -1.07083308 0.89889070 821.75 1.06192499e+00 -2.36340992e+00 2.59102125e+00 -1.14850886 0.93793918 822.00 9.70743583e-01 -2.68284409e+00 2.85306774e+00 -1.22361832 0.93769168 822.25 7.36887690e-01 -2.98033543e+00 3.07008187e+00 -1.32840765 0.94657025 822.50 4.16457588e-01 -3.04620867e+00 3.07454455e+00 -1.43492524 0.95665937 822.75 9.73129396e-02 -3.07364692e+00 3.07518702e+00 -1.53914648 0.95586194 823.00 -1.93226024e-01 -3.12308057e+00 3.12905234e+00 -1.63258789 0.95923105 823.25 -3.58851749e-01 -3.04448119e+00 3.06555710e+00 -1.68812456 0.96270241 823.50 -3.80176674e-01 -3.03720347e+00 3.06090496e+00 -1.69532192 0.96794505 823.75 -4.31880567e-01 -3.05952407e+00 3.08985572e+00 -1.71102919 0.97443050 824.00 -5.64013839e-01 -3.15498020e+00 3.20499792e+00 -1.74769701 0.96196681 824.25 -6.85795876e-01 -3.26818869e+00 3.33936720e+00 -1.77763503 0.95156198 824.50 -1.05766518e+00 -3.43611556e+00 3.59521150e+00 -1.86940129 0.95011360 824.75 -1.31896441e+00 -3.56169669e+00 3.79807194e+00 -1.92545692 0.96607708 825.00 -1.68240533e+00 -3.70771401e+00 4.07156369e+00 -1.99677111 0.96343116 825.25 -2.10535021e+00 -3.69166790e+00 4.24981310e+00 -2.08908963 0.96669923 825.50 -2.50064449e+00 -3.49065998e+00 4.29394107e+00 -2.19243224 0.93583115 825.75 -2.82719755e+00 -3.27482491e+00 4.32637541e+00 -2.28296844 0.92679322 826.00 -3.50339551e+00 -2.65850212e+00 4.39788741e+00 -2.49246054 0.93172248 826.25 -3.73148389e+00 -2.22950308e+00 4.34679836e+00 -2.60302498 0.93642184 826.50 -3.48868369e+00 -1.58012677e+00 3.82984523e+00 -2.71630546 0.93389804 826.75 -3.53282871e+00 -1.26101061e+00 3.75113669e+00 -2.79874795 0.93504978 827.00 -3.38547830e+00 -8.53247872e-01 3.49134577e+00 -2.89470271 0.93337592 827.25 -3.26803024e+00 -7.07933867e-01 3.34382895e+00 -2.92826474 0.94185677 827.50 -3.07097502e+00 -4.34121416e-01 3.10150754e+00 -3.00116043 0.96399881 827.75 -2.93625129e+00 -3.93715264e-01 2.96252989e+00 -3.00829998 0.96072432 828.00 -2.88917851e+00 -3.52254503e-01 2.91057309e+00 -3.02026942 0.93026715 828.25 -2.93186584e+00 -2.81532167e-01 2.94535188e+00 -3.04586126 0.92157800 828.50 -2.84907401e+00 -1.21570832e-01 2.85166656e+00 -3.09894823 0.94927635 828.75 -2.83760936e+00 5.77162563e-02 2.83819626e+00 3.12125571 0.93656604 829.00 -2.82114970e+00 4.38509804e-01 2.85502652e+00 2.98739006 0.91063137 829.25 -2.83221029e+00 8.13825699e-01 2.94681649e+00 2.86178462 0.91653354 829.50 -2.60566452e+00 1.42145938e+00 2.96817020e+00 2.64219038 0.94096701 829.75 -2.35277991e+00 1.64363499e+00 2.87003646e+00 2.53181178 0.92965975 830.00 -1.62720562e+00 1.91357929e+00 2.51188850e+00 2.27549157 0.90920955 830.25 -1.15352435e+00 1.86003646e+00 2.18868774e+00 2.12590923 0.88141324 830.50 -4.91101028e-01 1.60170187e+00 1.67529971e+00 1.86830809 0.85687144 830.75 -2.55804065e-01 1.40804131e+00 1.43108911e+00 1.75050996 0.80660331 831.00 -3.09509217e-02 9.96543881e-01 9.97024406e-01 1.60184461 0.77285033 831.25 7.22157634e-02 8.44359671e-01 8.47442252e-01 1.48547670 0.72040094 831.50 1.56422346e-01 5.41582482e-01 5.63719376e-01 1.28962346 0.58649917 831.75 9.78329801e-02 3.64307454e-01 3.77215076e-01 1.30844104 0.40214754 832.00 5.29990561e-02 2.12278591e-01 2.18794653e-01 1.32613067 0.25478796 832.25 5.81138195e-02 1.05694917e-01 1.20617708e-01 1.06808667 0.07832500 832.50 -3.94243046e-02 -1.86457000e-02 4.36112133e-02 -2.69981878 0.01200084 832.75 -7.01981541e-02 -4.97751012e-02 8.60542941e-02 -2.52480822 0.04197006 833.00 -1.16284775e-01 -1.60887201e-03 1.16295904e-01 -3.12775792 0.09923802 833.25 -1.19090981e-01 4.75409845e-02 1.28229509e-01 2.76177710 0.12105268 833.50 -7.40599730e-02 2.27597669e-02 7.74782976e-02 2.84343811 0.04670487 833.75 -8.64705996e-04 -1.09869338e-02 1.10209088e-02 -1.64933755 0.00097844 834.00 7.74618192e-02 -3.82607381e-02 8.63957031e-02 -0.45878005 0.06003403 834.25 1.62286968e-01 -7.98578915e-02 1.80871067e-01 -0.45729017 0.18026610 834.50 2.28549329e-01 -8.86899356e-02 2.45154442e-01 -0.37016760 0.22571023 834.75 3.35000106e-01 -2.66710822e-01 4.28205247e-01 -0.67238986 0.44852796 835.00 3.66526396e-01 -3.74217697e-01 5.23813405e-01 -0.79578100 0.68431299 835.25 3.67497711e-01 -4.63686845e-01 5.91658734e-01 -0.90061103 0.71415190 835.50 3.47757386e-01 -5.67871309e-01 6.65892652e-01 -1.02131800 0.77706906 835.75 2.83569468e-01 -6.90101464e-01 7.46090929e-01 -1.18092046 0.76098468 836.00 2.98979948e-01 -7.90222607e-01 8.44890986e-01 -1.20909277 0.78070150 836.25 2.72898682e-01 -9.27830635e-01 9.67131520e-01 -1.28473763 0.81253231 836.50 2.32857690e-01 -1.07470480e+00 1.09964227e+00 -1.35742326 0.88727412 836.75 1.04077687e-01 -1.19238686e+00 1.19692047e+00 -1.48373182 0.88260097 837.00 -1.78164383e-02 -1.27904841e+00 1.27917249e+00 -1.58472487 0.92463039 837.25 -1.64674135e-01 -1.35169144e+00 1.36168547e+00 -1.69202711 0.94053945 837.50 -2.46185540e-01 -1.31853212e+00 1.34131811e+00 -1.75538276 0.94330844 837.75 -3.19555687e-01 -1.15639841e+00 1.19973878e+00 -1.84040513 0.92938771 838.00 -3.27829318e-01 -1.13728781e+00 1.18359437e+00 -1.85144371 0.91231852 838.25 -3.49816983e-01 -1.18316729e+00 1.23379770e+00 -1.85826808 0.91832983 838.50 -3.28010344e-01 -1.16340442e+00 1.20875996e+00 -1.84560316 0.89938438 838.75 -2.76271372e-01 -1.16813672e+00 1.20036214e+00 -1.80303502 0.92461195 839.00 -3.02210128e-01 -1.18999280e+00 1.22776783e+00 -1.81949821 0.92221923 839.25 -3.35459325e-01 -1.21660133e+00 1.26200307e+00 -1.83984555 0.89007151 839.50 -3.46373385e-01 -1.32427058e+00 1.36881960e+00 -1.82662305 0.89537920 839.75 -4.35581705e-01 -1.43102037e+00 1.49584448e+00 -1.86627155 0.91771103 840.00 -5.58850754e-01 -1.43621267e+00 1.54111031e+00 -1.94188332 0.92193941 840.25 -6.84888382e-01 -1.41539476e+00 1.57239131e+00 -2.02146907 0.90993876 840.50 -7.59590569e-01 -1.37211654e+00 1.56833722e+00 -2.07639192 0.89781976 840.75 -7.76163375e-01 -1.20247406e+00 1.43121398e+00 -2.14398185 0.83627476 841.00 -6.82421491e-01 -1.18167057e+00 1.36456748e+00 -2.09451167 0.79477465 841.25 -5.69605186e-01 -1.28294137e+00 1.40370532e+00 -1.98863593 0.85770489 841.50 -4.77093099e-01 -1.34752875e+00 1.42949346e+00 -1.91107496 0.83422848 841.75 -5.08356740e-01 -1.56517948e+00 1.64566502e+00 -1.88483949 0.87219982 842.00 -6.48940617e-01 -1.76533039e+00 1.88082835e+00 -1.92306617 0.86446681 842.25 -9.04979760e-01 -1.96903462e+00 2.16704538e+00 -2.00160968 0.88748237 842.50 -1.06909989e+00 -2.13452957e+00 2.38729786e+00 -2.03513148 0.91601170 842.75 -1.27081492e+00 -2.23067889e+00 2.56727460e+00 -2.08863743 0.93533243 843.00 -1.45820017e+00 -2.20784835e+00 2.64592934e+00 -2.15449115 0.92265840 843.25 -1.79829203e+00 -2.16522234e+00 2.81461223e+00 -2.26388061 0.93384870 843.50 -1.97309091e+00 -1.96165048e+00 2.78229408e+00 -2.35910202 0.91608244 843.75 -2.37510123e+00 -1.86532480e+00 3.02002359e+00 -2.47583852 0.93771215 844.00 -2.55776730e+00 -1.61011062e+00 3.02235500e+00 -2.57976501 0.91132147 844.25 -2.78081436e+00 -1.40800723e+00 3.11695571e+00 -2.67289460 0.93074008 844.50 -2.66019782e+00 -1.28002115e+00 2.95213594e+00 -2.69311800 0.94786251 844.75 -2.83408588e+00 -1.17676888e+00 3.06868503e+00 -2.74803491 0.95950886 845.00 -2.87435907e+00 -7.94570487e-01 2.98216068e+00 -2.87189378 0.94895555 845.25 -2.73134603e+00 -6.36456477e-01 2.80451921e+00 -2.91265851 0.93871751 845.50 -2.74672496e+00 -5.51490145e-01 2.80154232e+00 -2.94344626 0.94026035 845.75 -2.64967810e+00 -4.43362586e-01 2.68651530e+00 -2.97580160 0.92570304 846.00 -2.45978589e+00 -2.15208330e-01 2.46918230e+00 -3.05432419 0.88867621 846.25 -2.33608289e+00 -2.63778976e-02 2.33623181e+00 -3.13030163 0.87153521 846.50 -2.24097755e+00 7.08274899e-02 2.24209654e+00 3.10999755 0.84306292 846.75 -2.20360112e+00 5.76863381e-02 2.20435606e+00 3.11542042 0.83903321 847.00 -2.11187249e+00 -8.63084809e-02 2.11363540e+00 -3.10074716 0.85556438 847.25 -2.09073669e+00 -7.06259156e-02 2.09192924e+00 -3.10782510 0.87308540 847.50 -1.94766184e+00 -2.72577438e-01 1.96664310e+00 -3.00254466 0.80714953 847.75 -1.95131627e+00 -2.57947631e-01 1.96829168e+00 -3.01016307 0.81992933 848.00 -2.01421294e+00 -2.97557656e-01 2.03607326e+00 -2.99492447 0.79894876 848.25 -2.06809030e+00 -4.12486766e-01 2.10882498e+00 -2.94472313 0.78359553 848.50 -2.24177272e+00 -4.59565411e-01 2.28839360e+00 -2.93939320 0.83511740 848.75 -2.22732706e+00 -3.99707699e-01 2.26290788e+00 -2.96402648 0.84912441 849.00 -2.32455889e+00 -3.74135927e-01 2.35447483e+00 -2.98201201 0.83026318 849.25 -2.40150109e+00 -3.74627126e-01 2.43054582e+00 -2.98684283 0.82608474 849.50 -2.63578912e+00 -2.76924844e-01 2.65029652e+00 -3.03691333 0.82357131 849.75 -2.56441418e+00 -2.79922732e-01 2.57964665e+00 -3.03286652 0.78836162 850.00 -2.52811766e+00 -5.06862199e-01 2.57842747e+00 -2.94372603 0.74689401 850.25 -2.79427615e+00 -6.47680032e-01 2.86835643e+00 -2.91382664 0.75611219 850.50 -3.18987387e+00 -9.70717285e-01 3.33430463e+00 -2.84618449 0.81223817 850.75 -3.51862602e+00 -9.63823837e-01 3.64824416e+00 -2.87423031 0.81257279 851.00 -4.30372800e+00 -3.95161190e-01 4.32183145e+00 -3.05003104 0.87203838 851.25 -4.39536667e+00 1.31780517e-01 4.39734173e+00 3.11161994 0.86150237 851.50 -4.84068214e+00 6.56151792e-01 4.88495023e+00 3.00686435 0.87451449 851.75 -4.97086194e+00 9.61253461e-01 5.06295138e+00 2.95057280 0.86592810 852.00 -5.26030304e+00 1.30556351e+00 5.41989706e+00 2.89831665 0.89461414 852.25 -5.33889294e+00 1.78544332e+00 5.62952801e+00 2.81886261 0.86756968 852.50 -5.24727719e+00 2.52265031e+00 5.82217163e+00 2.69345992 0.89623134 852.75 -5.66168267e+00 3.16475367e+00 6.48616346e+00 2.63188301 0.90311205 853.00 -5.92278257e+00 3.92409452e+00 7.10477805e+00 2.55645076 0.91995300 853.25 -5.76633503e+00 5.26795882e+00 7.81037834e+00 2.40132993 0.90765645 853.50 -5.10091625e+00 6.87843918e+00 8.56342642e+00 2.20888713 0.93315779 853.75 -3.60291903e+00 7.33523875e+00 8.17231626e+00 2.02736268 0.92725248 854.00 -2.49303878e+00 7.87395610e+00 8.25920257e+00 1.87742871 0.94555973 854.25 -1.15485353e+00 7.62631836e+00 7.71326250e+00 1.72108453 0.93804253 854.50 1.65906457e-01 7.51559807e+00 7.51742904e+00 1.54872496 0.96259637 854.75 1.05930477e+00 6.82425611e+00 6.90598277e+00 1.41679894 0.95423392 855.00 1.65421571e+00 6.04991942e+00 6.27199766e+00 1.30389243 0.96588263 855.25 1.79506826e+00 5.27318445e+00 5.57034508e+00 1.24268635 0.95932760 855.50 1.95128394e+00 4.69554036e+00 5.08484103e+00 1.17694760 0.96433874 855.75 2.12507205e+00 4.18849441e+00 4.69674533e+00 1.10127854 0.95850154 856.00 2.18585555e+00 3.97325577e+00 4.53483472e+00 1.06784397 0.96427277 856.25 2.24190151e+00 3.51687639e+00 4.17067643e+00 1.00328037 0.96403167 856.50 2.16171649e+00 3.24705204e+00 3.90081596e+00 0.98343040 0.96610825 856.75 2.03710082e+00 2.88220048e+00 3.52942762e+00 0.95553007 0.95322719 857.00 2.05790668e+00 2.65178883e+00 3.35662984e+00 0.91083390 0.96155482 857.25 1.95994158e+00 2.47505674e+00 3.15709944e+00 0.90102783 0.95328699 857.50 1.86903894e+00 2.32187698e+00 2.98067430e+00 0.89303286 0.94558907 857.75 1.68006088e+00 2.17515230e+00 2.74843448e+00 0.91312037 0.94879859 858.00 1.64910790e+00 2.06551646e+00 2.64308818e+00 0.89703189 0.93722942 858.25 1.70943395e+00 1.90133867e+00 2.55680526e+00 0.83849603 0.93212827 858.50 1.65878346e+00 1.77107920e+00 2.42657868e+00 0.81812707 0.93572694 858.75 1.52315174e+00 1.49657474e+00 2.13535177e+00 0.77659726 0.89542432 859.00 1.40700757e+00 1.59417772e+00 2.12628147e+00 0.84768291 0.89750332 859.25 1.20260047e+00 1.63056001e+00 2.02607350e+00 0.93531852 0.89816285 859.50 1.20277126e+00 1.53801468e+00 1.95247224e+00 0.90711010 0.89796336 859.75 1.31732488e+00 1.60806701e+00 2.07875549e+00 0.88445856 0.91454565 860.00 1.40939257e+00 1.60653150e+00 2.13713146e+00 0.85067132 0.91752152 860.25 1.48470088e+00 1.57686547e+00 2.16583504e+00 0.81549281 0.92561754 860.50 1.45991206e+00 1.44340166e+00 2.05298602e+00 0.77971148 0.89964245 860.75 1.32262828e+00 1.10036559e+00 1.72050865e+00 0.69392356 0.85669430 861.00 1.14248023e+00 1.09139286e+00 1.57999982e+00 0.76253274 0.85086985 861.25 8.07966917e-01 1.04214988e+00 1.31866861e+00 0.91130598 0.89669132 861.50 7.00805351e-01 1.05291796e+00 1.26481792e+00 0.98354363 0.87630732 861.75 4.43771694e-01 1.21476301e+00 1.29328361e+00 1.22054314 0.86704846 862.00 4.56381270e-01 1.34758890e+00 1.42277184e+00 1.24425492 0.85585530 862.25 2.78094281e-01 1.63732822e+00 1.66077697e+00 1.40255547 0.88778253 862.50 3.92091566e-01 1.79089699e+00 1.83331608e+00 1.35526127 0.87225752 862.75 4.40242037e-01 2.10448668e+00 2.15004122e+00 1.36457801 0.86739479 863.00 4.25832946e-01 2.21101110e+00 2.25164468e+00 1.38052957 0.79922332 863.25 9.59446291e-01 2.35779661e+00 2.54553374e+00 1.18433445 0.81271826 863.50 1.35452164e+00 2.52445621e+00 2.86489232e+00 1.07833043 0.85450600 863.75 1.64400612e+00 2.59195913e+00 3.06936610e+00 1.00555754 0.90310549 864.00 1.88059335e+00 2.52494127e+00 3.14832651e+00 0.93062718 0.88602348 864.25 1.90009009e+00 2.46783425e+00 3.11457031e+00 0.91465380 0.89771826 864.50 2.00166992e+00 2.08864963e+00 2.89294655e+00 0.80665973 0.88018737 864.75 2.12620265e+00 1.86184770e+00 2.82616605e+00 0.71920823 0.90656441 865.00 2.19719958e+00 1.79308303e+00 2.83598885e+00 0.68446713 0.88279071 865.25 2.32180065e+00 1.74913783e+00 2.90692990e+00 0.64564422 0.87232733 865.50 2.56042579e+00 1.56090941e+00 2.99870278e+00 0.54746947 0.89323791 865.75 2.62672317e+00 1.43386383e+00 2.99259755e+00 0.49967109 0.91624963 866.00 2.79614542e+00 1.25382571e+00 3.06439360e+00 0.42153272 0.91215395 866.25 2.89214007e+00 9.72916674e-01 3.05139985e+00 0.32450824 0.89341488 866.50 2.64272960e+00 7.74477895e-01 2.75387649e+00 0.28507757 0.81274642 866.75 2.68245232e+00 7.69134200e-01 2.79054079e+00 0.27923662 0.80331856 867.00 2.70645350e+00 5.71961306e-01 2.76623034e+00 0.20826797 0.80397909 867.25 2.71065021e+00 2.02937625e-01 2.71823623e+00 0.07472736 0.80176549 867.50 2.40382550e+00 -4.98168955e-01 2.45490313e+00 -0.20434737 0.74485364 867.75 2.14783696e+00 -6.09937434e-01 2.23276225e+00 -0.27669324 0.74505213 868.00 1.80177684e+00 -4.37536072e-01 1.85414066e+00 -0.23822468 0.73690260 868.25 1.72623187e+00 -3.33335986e-01 1.75812097e+00 -0.19075257 0.79519174 868.50 1.54265902e+00 -2.00224230e-01 1.55559847e+00 -0.12907009 0.78890531 868.75 1.62770430e+00 -9.58133368e-02 1.63052185e+00 -0.05879625 0.78402749 869.00 1.73084019e+00 -1.94158717e-01 1.74169612e+00 -0.11170899 0.75475273 869.25 1.62810436e+00 -1.06779292e-01 1.63160217e+00 -0.06549125 0.61844829 869.50 1.33063006e+00 -1.20283792e-01 1.33605560e+00 -0.09015109 0.45918819 869.75 1.37965224e+00 -4.25200233e-01 1.44368817e+00 -0.29895697 0.50458865 870.00 1.09869765e+00 -6.95693571e-01 1.30043303e+00 -0.56447307 0.56944263 870.25 8.21710730e-01 -7.28653112e-01 1.09824582e+00 -0.72544701 0.52103712 870.50 6.35103922e-01 -7.39762872e-01 9.74990307e-01 -0.86137461 0.50649108 870.75 5.72804391e-01 -6.20395250e-01 8.44390394e-01 -0.82526211 0.38843432 871.00 7.25961883e-01 -3.42559029e-01 8.02724949e-01 -0.44089076 0.40441338 871.25 6.75850345e-01 -3.37558620e-01 7.55459800e-01 -0.46321363 0.48140079 871.50 6.62395873e-01 -7.41741411e-02 6.66535892e-01 -0.11151402 0.50047657 871.75 7.35618069e-01 1.52459590e-01 7.51250871e-01 0.20436047 0.47703728 872.00 9.41146758e-01 4.53084509e-01 1.04452994e+00 0.44867139 0.56798526 872.25 1.02429240e+00 4.73514220e-01 1.12844612e+00 0.43302240 0.65117726 872.50 1.17680786e+00 4.44444392e-01 1.25793782e+00 0.36110896 0.69753692 872.75 1.48339634e+00 4.07037872e-01 1.53822772e+00 0.26780450 0.67365779 873.00 1.87783156e+00 2.15553013e-01 1.89016255e+00 0.11428804 0.72388370 873.25 2.01558864e+00 -4.19460393e-02 2.01602505e+00 -0.02080781 0.77463887 873.50 1.79101453e+00 -3.21620939e-01 1.81966291e+00 -0.17768098 0.72070084 873.75 1.74729661e+00 -3.49528130e-01 1.78191340e+00 -0.19743343 0.74726126 874.00 1.87410299e+00 -5.01967190e-01 1.94016316e+00 -0.26170121 0.79356804 874.25 1.67288829e+00 -5.46807990e-01 1.75998699e+00 -0.31591746 0.76129010 874.50 1.34826834e+00 -5.74864476e-01 1.46570689e+00 -0.40303255 0.75044950 874.75 1.35745810e+00 -4.88351135e-01 1.44262931e+00 -0.34533789 0.78999084 875.00 1.41057825e+00 -3.92382813e-01 1.46413636e+00 -0.27131243 0.85828224 875.25 1.52917969e+00 -4.13715057e-01 1.58415614e+00 -0.26422165 0.80507639 875.50 1.70015450e+00 -4.68191313e-01 1.76344221e+00 -0.26872097 0.83034754 875.75 1.64035674e+00 -3.88187503e-01 1.68566300e+00 -0.23237335 0.84233387 876.00 1.66154199e+00 -3.70912571e-01 1.70243881e+00 -0.21963285 0.88490445 876.25 1.69538000e+00 -5.51176919e-01 1.78272525e+00 -0.31432708 0.89765795 876.50 1.72564914e+00 -6.53463470e-01 1.84523154e+00 -0.36199035 0.91845605 876.75 1.76324878e+00 -5.36486723e-01 1.84305840e+00 -0.29536079 0.88624043 877.00 1.74207553e+00 -5.14637868e-01 1.81650194e+00 -0.28724647 0.86615621 877.25 1.64534700e+00 -3.74134032e-01 1.68734792e+00 -0.22358729 0.82869441 877.50 1.67297900e+00 -4.28437225e-01 1.72696763e+00 -0.25070443 0.84065293 877.75 1.62455031e+00 -4.86111920e-01 1.69572064e+00 -0.29074894 0.82198703 878.00 1.50729524e+00 -4.19180248e-01 1.56449705e+00 -0.27124685 0.81593639 878.25 1.59891075e+00 -3.78650218e-01 1.64313468e+00 -0.23253374 0.85151159 878.50 1.55053550e+00 -3.31474804e-01 1.58557115e+00 -0.21061059 0.89140101 878.75 1.41638123e+00 -1.89288597e-01 1.42897374e+00 -0.13285520 0.92226185 879.00 1.33209265e+00 -1.84653001e-01 1.34482993e+00 -0.13774098 0.91159900 879.25 1.20297230e+00 2.14948917e-02 1.20316432e+00 0.01786625 0.88864323 879.50 1.16054465e+00 1.42763660e-01 1.16929267e+00 0.12239943 0.91314246 879.75 9.94132706e-01 2.39447084e-01 1.02256283e+00 0.23635825 0.90247181 880.00 9.00072835e-01 2.77852611e-01 9.41983642e-01 0.29941934 0.87088218 880.25 7.19657774e-01 2.86001935e-01 7.74405848e-01 0.37827491 0.92497205 880.50 6.25124576e-01 2.91715773e-01 6.89839712e-01 0.43661530 0.91735067 880.75 4.83854224e-01 2.98330347e-01 5.68432851e-01 0.55251483 0.94089580 881.00 4.29530602e-01 3.06594531e-01 5.27727908e-01 0.61992098 0.93806744 881.25 3.35068590e-01 2.95341847e-01 4.46651729e-01 0.72246412 0.92603720 881.50 2.79894306e-01 2.70775827e-01 3.89435965e-01 0.76884080 0.87749537 881.75 1.89224466e-01 2.39230471e-01 3.05019863e-01 0.90158491 0.88742799 882.00 1.67484962e-01 2.21540252e-01 2.77725216e-01 0.92346474 0.86759878 882.25 9.93503060e-02 1.87022954e-01 2.11773626e-01 1.08248589 0.73722223 882.50 5.47308870e-02 1.64941435e-01 1.73784772e-01 1.25040828 0.65424731 882.75 2.82512253e-02 1.30978009e-01 1.33990188e-01 1.35835653 0.59326015 883.00 1.75515732e-02 1.11258874e-01 1.12634785e-01 1.41433141 0.40002346 883.25 -1.69584096e-02 8.08514575e-02 8.26108095e-02 1.77754689 0.27993924 883.50 4.27409534e-03 7.43866853e-02 7.45093741e-02 1.51340163 0.22561270 883.75 3.02677489e-02 3.27365116e-02 4.45849282e-02 0.82456219 0.07245099 884.00 2.66468023e-02 -1.90272150e-02 3.27427394e-02 -0.62009502 0.03454198 884.25 4.26880417e-03 -4.06688788e-02 4.08923024e-02 -1.46621440 0.06408356 884.50 -4.55328141e-04 -9.81610871e-02 9.81621432e-02 -1.57543487 0.19828617 884.75 -1.98263456e-02 -1.88873940e-01 1.89911688e-01 -1.67538461 0.48344529 885.00 -1.24752923e-02 -2.44206905e-01 2.44525347e-01 -1.62183689 0.51850017 885.25 -2.40359278e-02 -2.86588560e-01 2.87594730e-01 -1.65446962 0.49453911 885.50 -5.72904009e-02 -2.47278426e-01 2.53828308e-01 -1.79846331 0.37810390 885.75 -1.36525243e-01 -2.29547404e-01 2.67078926e-01 -2.10735278 0.41137600 886.00 -1.14110151e-01 -1.71028068e-01 2.05600892e-01 -2.15916898 0.32808787 886.25 -7.89815092e-02 -1.28431401e-01 1.50773684e-01 -2.12215081 0.24077522 886.50 -3.63991018e-02 -1.30681638e-01 1.35656128e-01 -1.84244383 0.25530948 886.75 -2.57967071e-02 -1.57575365e-01 1.59672997e-01 -1.73306715 0.44212325 887.00 -9.42859861e-03 -2.38229639e-01 2.38416147e-01 -1.61035345 0.64061609 887.25 -4.94366798e-02 -3.02926302e-01 3.06933754e-01 -1.73256728 0.77131575 887.50 -4.15731063e-02 -3.37606168e-01 3.40156211e-01 -1.69332034 0.71919736 887.75 -4.58052374e-02 -3.41289180e-01 3.44349276e-01 -1.70421146 0.66428840 888.00 -4.54527582e-02 -3.56188286e-01 3.59076661e-01 -1.69771915 0.54788402 888.25 -6.86413375e-02 -3.04703937e-01 3.12339755e-01 -1.79236987 0.49561768 888.50 -6.55690525e-02 -3.49745058e-01 3.55838314e-01 -1.75612178 0.65438845 888.75 -8.96908307e-02 -3.60184809e-01 3.71183973e-01 -1.81484618 0.70413121 889.00 -1.36685735e-01 -3.00191369e-01 3.29845188e-01 -1.99807273 0.61727178 889.25 -1.19981239e-01 -2.78887614e-01 3.03601382e-01 -1.97707462 0.52317318 889.50 -9.17073224e-02 -2.64656026e-01 2.80094707e-01 -1.90436324 0.53397330 889.75 -7.29116666e-02 -2.81322979e-01 2.90617841e-01 -1.82439075 0.56985598 890.00 -5.08359494e-02 -3.20517130e-01 3.24523535e-01 -1.72809212 0.58422982 890.25 -6.24036842e-02 -2.71602490e-01 2.78679265e-01 -1.79663780 0.52482464 890.50 -2.95992588e-02 -2.46045560e-01 2.47819559e-01 -1.69052090 0.53802970 890.75 -2.22787120e-02 -2.50982851e-01 2.51969706e-01 -1.65933016 0.55718399 891.00 -1.04320416e-02 -2.42616811e-01 2.42840986e-01 -1.61376787 0.48987953 891.25 1.61129335e-02 -2.20261549e-01 2.20850122e-01 -1.49777276 0.43452572 891.50 3.61516659e-02 -1.75141422e-01 1.78833612e-01 -1.36724100 0.38081625 891.75 1.11058744e-02 -2.10054657e-01 2.10348044e-01 -1.51797415 0.41381068 892.00 -3.41355465e-02 -1.98099867e-01 2.01019385e-01 -1.74143544 0.29620028 892.25 -1.12148416e-01 -1.13636307e-01 1.59657375e-01 -2.34960472 0.17862349 892.50 -2.06777490e-01 -7.85712209e-02 2.21202096e-01 -2.77846350 0.33152139 892.75 -2.63790037e-01 -4.14835656e-02 2.67031964e-01 -2.98561034 0.45066837 893.00 -3.72266955e-01 -5.70738952e-02 3.76616669e-01 -2.98946280 0.67379644 893.25 -4.12415749e-01 -3.87046806e-02 4.14227959e-01 -3.04801804 0.76193073 893.50 -4.26812688e-01 1.52184518e-02 4.27083917e-01 3.10595171 0.76290749 893.75 -4.90217290e-01 6.41970218e-02 4.94402922e-01 3.01137740 0.77853862 894.00 -5.75811836e-01 2.00289906e-01 6.09651800e-01 2.80684415 0.85235665 894.25 -6.06203022e-01 2.59733011e-01 6.59502343e-01 2.73679603 0.88471021 894.50 -6.72313044e-01 3.03371334e-01 7.37589992e-01 2.71771198 0.92164999 894.75 -7.28974415e-01 3.86599726e-01 8.25144258e-01 2.65397356 0.92254709 895.00 -8.13653064e-01 4.94671638e-01 9.52224416e-01 2.59533796 0.95551851 895.25 -8.17999484e-01 5.67010021e-01 9.95300719e-01 2.53546752 0.94317177 895.50 -8.54589184e-01 6.63513280e-01 1.08193001e+00 2.48140105 0.93954776 895.75 -8.98133070e-01 7.63454971e-01 1.17877330e+00 2.43707153 0.93510605 896.00 -9.73084304e-01 8.46952121e-01 1.29004688e+00 2.42538587 0.92515210 896.25 -1.04963874e+00 9.81665707e-01 1.43715310e+00 2.38964476 0.91369697 896.50 -1.00349371e+00 1.06517439e+00 1.46341932e+00 2.32638671 0.91370786 896.75 -9.53292557e-01 1.06754705e+00 1.43123143e+00 2.29971649 0.89320315 897.00 -9.40548229e-01 1.16157518e+00 1.49461964e+00 2.25143480 0.86029363 897.25 -9.90815872e-01 1.25683729e+00 1.60042372e+00 2.23838734 0.83510441 897.50 -9.03187395e-01 1.36615183e+00 1.63771740e+00 2.15494761 0.86575060 897.75 -8.01883126e-01 1.50810651e+00 1.70804033e+00 2.05949300 0.86922323 898.00 -7.75653800e-01 1.70901400e+00 1.87679719e+00 1.99685593 0.87980808 898.25 -5.85752458e-01 1.82908717e+00 1.92058997e+00 1.88071973 0.87456483 898.50 -4.57692510e-01 1.81489454e+00 1.87171703e+00 1.81783213 0.86830876 898.75 -1.20158285e-01 1.79739003e+00 1.80140193e+00 1.63754854 0.75908122 899.00 1.60267395e-01 1.87355990e+00 1.88040217e+00 1.48546242 0.82036197 899.25 6.36046340e-01 1.99151818e+00 2.09062183e+00 1.26165805 0.84125094 899.50 7.09761598e-01 2.02988803e+00 2.15039692e+00 1.23442841 0.87551811 899.75 7.88393377e-01 1.97941332e+00 2.13064338e+00 1.19175935 0.86015408 900.00 9.40339447e-01 1.85558387e+00 2.08024753e+00 1.10175374 0.80108930 900.25 1.19878591e+00 1.78032512e+00 2.14630967e+00 0.97817952 0.83142724 900.50 1.42748232e+00 1.88613414e+00 2.36541916e+00 0.92293853 0.87666656 900.75 1.46600100e+00 1.67430192e+00 2.22540914e+00 0.85163261 0.83652566 901.00 1.32092979e+00 1.45425250e+00 1.96461341e+00 0.83340232 0.84517926 901.25 1.31902504e+00 1.35976837e+00 1.89441207e+00 0.80060657 0.89626620 901.50 1.34392598e+00 1.28158239e+00 1.85703809e+00 0.76165728 0.88526748 901.75 1.44614970e+00 1.21825236e+00 1.89089602e+00 0.70007171 0.86800562 902.00 1.43772085e+00 1.30496477e+00 1.94164216e+00 0.73703223 0.90523244 902.25 1.45481308e+00 1.32257129e+00 1.96613222e+00 0.73782031 0.93073295 902.50 1.44493990e+00 1.32091882e+00 1.95772262e+00 0.74058819 0.95189121 902.75 1.37777987e+00 1.28449119e+00 1.88366530e+00 0.75037148 0.94979916 903.00 1.42840002e+00 1.29771347e+00 1.92986705e+00 0.73749606 0.93193590 903.25 1.47892245e+00 1.29744788e+00 1.96737963e+00 0.72012705 0.91403212 903.50 1.26611580e+00 1.36890694e+00 1.86465960e+00 0.82438798 0.91868336 903.75 1.13714785e+00 1.45629931e+00 1.84767770e+00 0.90784325 0.92228691 904.00 1.11249436e+00 1.50252900e+00 1.86955532e+00 0.93345817 0.89891271 904.25 1.01899607e+00 1.56963839e+00 1.87139458e+00 0.99498961 0.90572956 904.50 1.04430987e+00 1.68536066e+00 1.98268093e+00 1.01606369 0.92592786 904.75 1.10759852e+00 1.70257825e+00 2.03114430e+00 0.99404024 0.94435476 905.00 9.95201608e-01 1.70737563e+00 1.97624841e+00 1.04305734 0.94953021 905.25 9.63577936e-01 1.67515605e+00 1.93251914e+00 1.04879912 0.95618834 905.50 8.56240637e-01 1.68330288e+00 1.88855940e+00 1.10023918 0.95684304 905.75 7.23527257e-01 1.68793966e+00 1.83647271e+00 1.16584221 0.95386358 906.00 6.37083395e-01 1.57363007e+00 1.69770046e+00 1.18611632 0.92474916 906.25 4.39113221e-01 1.51109863e+00 1.57360716e+00 1.28799289 0.90300195 906.50 3.92099393e-01 1.50630328e+00 1.55649976e+00 1.31614191 0.95465126 906.75 3.15917217e-01 1.50808623e+00 1.54082048e+00 1.36430012 0.95667020 907.00 2.23574018e-01 1.46025074e+00 1.47726692e+00 1.41886954 0.93874269 907.25 9.71541259e-02 1.46247596e+00 1.46569944e+00 1.50446253 0.93024403 907.50 -2.92447747e-02 1.34577664e+00 1.34609436e+00 1.59252369 0.80654670 907.75 -1.91325664e-01 1.27688264e+00 1.29113701e+00 1.71952793 0.77339400 908.00 -3.95723264e-01 1.33255354e+00 1.39007044e+00 1.85946743 0.80073741 908.25 -5.90973948e-01 1.38315917e+00 1.50412084e+00 1.97458293 0.79177425 908.50 -6.35212707e-01 1.51344618e+00 1.64134534e+00 1.96818014 0.75234154 908.75 -6.69356560e-01 1.41975225e+00 1.56962882e+00 2.01135248 0.70364662 909.00 -8.76025116e-01 1.24595945e+00 1.52310044e+00 2.18359498 0.66147729 909.25 -9.32580247e-01 1.45518160e+00 1.72836901e+00 2.14072550 0.71003698 909.50 -9.05471846e-01 1.85861769e+00 2.06744746e+00 2.02413130 0.77834541 909.75 -1.00414864e+00 1.94756896e+00 2.19119587e+00 2.04683864 0.79895347 910.00 -8.87906979e-01 1.76839709e+00 1.97878929e+00 2.03612018 0.75998245 910.25 -6.62307877e-01 1.77543160e+00 1.89494303e+00 1.92784797 0.77038761 910.50 -7.46393652e-01 1.56772229e+00 1.73633426e+00 2.01514234 0.79858794 910.75 -8.49295034e-01 1.47388252e+00 1.70106782e+00 2.09355434 0.79925622 911.00 -7.70718723e-01 1.15535076e+00 1.38882782e+00 2.15908943 0.63655155 911.25 -7.09186255e-01 1.02664803e+00 1.24777855e+00 2.17530643 0.54720419 911.50 -3.90302480e-01 9.69414445e-01 1.04503607e+00 1.95355647 0.44535560 911.75 -4.47792685e-01 9.05486001e-01 1.01015998e+00 2.03006076 0.48831581 912.00 -3.44815243e-01 9.00276325e-01 9.64051354e-01 1.93657130 0.55189750 912.25 -4.09145252e-01 9.29038324e-01 1.01514139e+00 1.98563536 0.62861456 912.50 -6.10431788e-01 7.41038848e-01 9.60086216e-01 2.25985298 0.67366882 912.75 -5.43783696e-01 6.40285103e-01 8.40039118e-01 2.27487439 0.64887842 913.00 -5.29108468e-01 3.63549078e-01 6.41968616e-01 2.53957871 0.61217805 913.25 -5.12308501e-01 3.38584270e-01 6.14084121e-01 2.55759356 0.63180424 913.50 -4.29616228e-01 1.66394796e-01 4.60713936e-01 2.77207330 0.52572688 913.75 -4.52155762e-01 6.37896070e-02 4.56633274e-01 3.00143878 0.46508746 914.00 -5.00700194e-01 -1.55006076e-01 5.24144606e-01 -2.84137146 0.66927792 914.25 -5.27074321e-01 -1.75219688e-01 5.55436116e-01 -2.82064785 0.67145767 914.50 -5.81742528e-01 -2.03989306e-01 6.16470605e-01 -2.80433691 0.67005858 914.75 -6.33250683e-01 -2.50249450e-01 6.80904703e-01 -2.76524637 0.72154156 915.00 -6.12178977e-01 -3.45342686e-01 7.02868886e-01 -2.62797307 0.76861426 915.25 -6.11447540e-01 -3.30922902e-01 6.95253955e-01 -2.64552130 0.75643970 915.50 -6.81528352e-01 -2.73754943e-01 7.34453990e-01 -2.75964057 0.83149949 915.75 -5.60361571e-01 -1.78707019e-01 5.88167738e-01 -2.83287536 0.73800821 916.00 -4.59854944e-01 -6.51635917e-02 4.64448988e-01 -3.00082521 0.71452792 916.25 -4.34676459e-01 -1.97493690e-02 4.35124881e-01 -3.09618924 0.64699316 916.50 -4.52458928e-01 7.10032307e-02 4.57996223e-01 2.98593466 0.55729918 916.75 -2.81245302e-01 1.91937982e-01 3.40498325e-01 2.54273742 0.40530153 917.00 -1.80242365e-01 2.82340477e-01 3.34967842e-01 2.13896407 0.46499677 917.25 -6.21308142e-03 3.32025370e-01 3.32083497e-01 1.58950681 0.44497271 917.50 8.08791102e-02 4.12124088e-01 4.19985350e-01 1.37700969 0.63935743 917.75 2.18553570e-01 5.30750888e-01 5.73987951e-01 1.18017464 0.76077990 918.00 3.43385803e-01 5.55667167e-01 6.53207326e-01 1.01726806 0.78704717 918.25 4.50515755e-01 6.35124291e-01 7.78683061e-01 0.95383284 0.89410830 918.50 4.90577080e-01 6.66053388e-01 8.27220036e-01 0.93596336 0.90875878 918.75 6.20638866e-01 6.78596797e-01 9.19611991e-01 0.82997786 0.82360330 919.00 6.73774493e-01 7.01921548e-01 9.72967588e-01 0.80585554 0.80860833 919.25 7.31188185e-01 8.75398504e-01 1.14059577e+00 0.87492017 0.83986273 919.50 7.92791136e-01 9.29509298e-01 1.22168135e+00 0.86461319 0.83683374 919.75 8.63791906e-01 9.76896296e-01 1.30401796e+00 0.84676780 0.79692893 920.00 8.65654057e-01 1.03028019e+00 1.34567241e+00 0.87201206 0.77431832 920.25 1.10122560e+00 1.14903388e+00 1.59153281e+00 0.80664064 0.75268159 920.50 1.18826578e+00 1.03862532e+00 1.57820092e+00 0.71830200 0.74095894 920.75 1.23046194e+00 1.06557639e+00 1.62772529e+00 0.71370817 0.74816855 921.00 1.23105741e+00 1.05622398e+00 1.62207011e+00 0.70910929 0.74066991 921.25 1.12388420e+00 9.29065632e-01 1.45817648e+00 0.69078460 0.69439757 921.50 1.10964716e+00 8.46959075e-01 1.39594287e+00 0.65193921 0.71257902 921.75 1.13168867e+00 9.72253448e-01 1.49197721e+00 0.70976344 0.72388318 922.00 9.68884048e-01 9.64120109e-01 1.36684450e+00 0.78293364 0.66494961 922.25 9.20743473e-01 8.71304031e-01 1.26765108e+00 0.75781692 0.68627714 922.50 9.51463765e-01 9.78395251e-01 1.36474927e+00 0.79935241 0.69103110 922.75 8.07682267e-01 1.18473706e+00 1.43385932e+00 0.97243102 0.73113598 923.00 8.06104924e-01 1.29428146e+00 1.52478512e+00 1.01376589 0.72867152 923.25 6.53935964e-01 1.48319139e+00 1.62095310e+00 1.15553744 0.75416222 923.50 6.51276847e-01 1.43725930e+00 1.57793404e+00 1.14533588 0.75638270 923.75 4.53120334e-01 1.34162762e+00 1.41608005e+00 1.24508568 0.64483944 924.00 2.09949139e-01 1.38180272e+00 1.39766140e+00 1.42001100 0.64206882 924.25 1.16152427e-01 1.46220769e+00 1.46681380e+00 1.49152644 0.60664313 924.50 -7.59687213e-02 1.43897437e+00 1.44097831e+00 1.62354102 0.53747703 924.75 -3.66749112e-01 1.40125311e+00 1.44845269e+00 1.82678358 0.59630841 925.00 -4.33778644e-01 1.37118241e+00 1.43816033e+00 1.87718819 0.57517353 925.25 -3.58606259e-01 1.46428156e+00 1.50755396e+00 1.81097165 0.51847869 925.50 -3.78866267e-01 1.22759096e+00 1.28472534e+00 1.87014781 0.44463990 925.75 -5.20874001e-01 1.00246353e+00 1.12970919e+00 2.04999596 0.36264626 926.00 -5.49584404e-01 1.11132925e+00 1.23979664e+00 2.03005746 0.28828979 926.25 -2.59122173e-01 1.37278257e+00 1.39702408e+00 1.75735821 0.30568726 926.50 -4.90305550e-01 8.89194778e-01 1.01541464e+00 2.07471682 0.22781151 926.75 -3.95660747e-01 7.06741911e-01 8.09957749e-01 2.08116107 0.15305624 927.00 -3.32158550e-01 5.54666200e-01 6.46516740e-01 2.11036543 0.07859724 927.25 -5.64483665e-01 6.75814271e-01 8.80549111e-01 2.26667322 0.15693412 927.50 -7.48854848e-01 6.76666989e-01 1.00928777e+00 2.40679087 0.25168902 927.75 -6.92175939e-01 5.55435436e-01 8.87477354e-01 2.46536060 0.20349370 928.00 -8.49732209e-01 5.96994999e-01 1.03848344e+00 2.52914501 0.19342950 928.25 -7.57728505e-01 6.69959400e-01 1.01143368e+00 2.41759361 0.14393043 928.50 -5.48349927e-01 7.58679807e-01 9.36099724e-01 2.19664034 0.12183496 928.75 -6.22467283e-01 7.67378264e-01 9.88096614e-01 2.25230577 0.10677665 929.00 -7.82485596e-01 9.86943371e-01 1.25950027e+00 2.24115453 0.14091706 929.25 -6.08051636e-01 6.92242237e-01 9.21371861e-01 2.29153738 0.07534788 929.50 -6.33047947e-01 1.13370161e+00 1.29847181e+00 2.08005837 0.16231212 929.75 -8.96871417e-01 1.35534580e+00 1.62522017e+00 2.15537265 0.25865192 930.00 -5.48734777e-01 1.86432435e+00 1.94340298e+00 1.85704725 0.38986484 930.25 -1.90019317e-01 1.87213794e+00 1.88175657e+00 1.67194849 0.35334914 930.50 1.57630019e-01 1.80892863e+00 1.81578358e+00 1.48387590 0.36550408 930.75 -8.38176104e-02 1.59346485e+00 1.59566777e+00 1.62334875 0.31463933 931.00 1.95109676e-01 1.01761862e+00 1.03615416e+00 1.38136362 0.22612802 931.25 3.65329237e-01 8.92014259e-01 9.63926807e-01 1.18207979 0.26268418 931.50 3.85981865e-01 5.91162436e-01 7.06013474e-01 0.99237102 0.15668960 931.75 4.07267046e-01 5.67857544e-01 6.98805150e-01 0.94862022 0.16535677 932.00 5.13446032e-01 5.43566880e-01 7.47724402e-01 0.81388665 0.29600164 932.25 5.41897027e-01 4.13872819e-01 6.81867361e-01 0.65224198 0.26296044 932.50 7.74074732e-01 8.23165927e-02 7.78439280e-01 0.10594376 0.33080650 932.75 7.45418577e-01 2.70697014e-02 7.45909930e-01 0.03629882 0.31377096 933.00 6.79772499e-01 -2.14665440e-01 7.12861769e-01 -0.30587946 0.31394056 933.25 7.62629154e-01 -3.76024686e-01 8.50292768e-01 -0.45808312 0.44797051 933.50 6.87829734e-01 -5.17619451e-01 8.60836593e-01 -0.64512479 0.37675413 933.75 5.53340860e-01 -5.19142268e-01 7.58745544e-01 -0.75352166 0.29804723 934.00 2.10417437e-01 -6.32991104e-01 6.67048150e-01 -1.24987008 0.24813140 934.25 5.24414541e-02 -5.33584766e-01 5.36155583e-01 -1.47282955 0.18886421 934.50 -1.36296640e-01 -5.49219547e-01 5.65878860e-01 -1.81404645 0.20494178 934.75 -2.21611163e-01 -3.83146074e-01 4.42619952e-01 -2.09518101 0.18545530 935.00 -2.85453439e-01 -3.25109467e-01 4.32642846e-01 -2.29133564 0.23849585 935.25 -2.33062827e-01 -2.74387175e-01 3.60009171e-01 -2.27493849 0.17535257 935.50 -8.65202339e-02 -1.97946829e-01 2.16029391e-01 -1.98286112 0.11893625 935.75 -5.34791329e-02 -2.78625185e-01 2.83711141e-01 -1.76042937 0.17215345 936.00 8.63072027e-03 -2.12102996e-01 2.12278521e-01 -1.53012759 0.10282683 936.25 1.13901337e-01 -3.38490959e-01 3.57140930e-01 -1.24620079 0.23334075 936.50 9.33414730e-02 -5.15012198e-01 5.23402517e-01 -1.39150132 0.38897166 936.75 1.43526512e-01 -6.63260574e-01 6.78612149e-01 -1.35768684 0.37743705 937.00 1.50481791e-01 -7.42772969e-01 7.57863083e-01 -1.37090721 0.39813018 937.25 -6.11585387e-03 -7.04682517e-01 7.04709056e-01 -1.57947499 0.44302760 937.50 -1.31811920e-01 -6.50236514e-01 6.63462061e-01 -1.77079995 0.41670564 937.75 -1.13237521e-01 -5.34455045e-01 5.46319441e-01 -1.77958339 0.32219950 938.00 -1.62257283e-01 -4.26341515e-01 4.56173775e-01 -1.93445052 0.30793721 938.25 -2.54315579e-01 -2.89664209e-01 3.85463056e-01 -2.29130421 0.22023636 938.50 -1.82914225e-01 -9.81824028e-02 2.07599128e-01 -2.64896552 0.10550043 938.75 -2.34905612e-01 8.82560181e-04 2.34907270e-01 3.13783559 0.17234301 939.00 -3.23957897e-01 -1.60506687e-02 3.24355272e-01 -3.09208760 0.37499776 939.25 -2.70586451e-01 8.79871359e-02 2.84532535e-01 2.82720520 0.31658457 939.50 -3.00107870e-01 1.50221520e-01 3.35605779e-01 2.67749841 0.43982809 939.75 -2.60963869e-01 2.51456159e-01 3.62398042e-01 2.37474689 0.52710763 940.00 -1.89818107e-01 2.79447345e-01 3.37819083e-01 2.16746852 0.54937217 940.25 -2.18119977e-01 3.39466648e-01 4.03502081e-01 2.14190744 0.60197270 940.50 -2.14852486e-01 3.70584870e-01 4.28362856e-01 2.09620496 0.68541737 940.75 -2.48083104e-01 4.55284933e-01 5.18487798e-01 2.06971276 0.71174691 941.00 -2.53134894e-01 4.75862666e-01 5.39001439e-01 2.05967563 0.74479670 941.25 -2.68191007e-01 6.14807916e-01 6.70757176e-01 1.98213122 0.82014072 941.50 -2.89384235e-01 6.87138568e-01 7.45588792e-01 1.96939632 0.87234573 941.75 -2.59988199e-01 7.62121021e-01 8.05246741e-01 1.89955427 0.87735486 942.00 -2.40899384e-01 7.79421088e-01 8.15800064e-01 1.87055765 0.88480033 942.25 -2.16318975e-01 8.30398833e-01 8.58111952e-01 1.82563276 0.90571602 942.50 -2.12910715e-01 9.06454788e-01 9.31123652e-01 1.80149730 0.90401864 942.75 -2.34311794e-01 1.06472427e+00 1.09020172e+00 1.78741154 0.92917797 943.00 -2.39185511e-01 1.12830531e+00 1.15337877e+00 1.77969037 0.94158637 943.25 -2.32606248e-01 1.22358670e+00 1.24549993e+00 1.75865669 0.92497502 943.50 -2.36212741e-01 1.28242343e+00 1.30399629e+00 1.75294717 0.93525125 943.75 -1.95358863e-01 1.26641183e+00 1.28139144e+00 1.72385158 0.94804465 944.00 -1.82012162e-01 1.27896665e+00 1.29185298e+00 1.71215899 0.93602283 944.25 -1.29353417e-01 1.44738538e+00 1.45315407e+00 1.65992993 0.93850961 944.50 -1.89862110e-01 1.45548477e+00 1.46781591e+00 1.70050986 0.92315554 944.75 -3.28277372e-01 1.44263746e+00 1.47951644e+00 1.79454000 0.88267614 945.00 -3.41939163e-01 1.37079661e+00 1.41280067e+00 1.81525312 0.87004098 945.25 -3.77331325e-01 1.39138874e+00 1.44164543e+00 1.83561738 0.93196571 945.50 -4.25701406e-01 1.38268258e+00 1.44673177e+00 1.86946743 0.93632174 945.75 -5.25978307e-01 1.52323100e+00 1.61148560e+00 1.90328184 0.95867554 946.00 -6.09366015e-01 1.62458206e+00 1.73510629e+00 1.92964672 0.95913922 946.25 -7.43147049e-01 1.76986847e+00 1.91955774e+00 1.96832936 0.97085883 946.50 -7.92610070e-01 1.90521985e+00 2.06351482e+00 1.96503654 0.97033338 946.75 -7.44917226e-01 2.06970676e+00 2.19967901e+00 1.91627611 0.96339064 947.00 -6.80911553e-01 2.17094885e+00 2.27522734e+00 1.87472579 0.96525274 947.25 -6.88152172e-01 2.28378623e+00 2.38521130e+00 1.86346437 0.97295536 947.50 -6.19833503e-01 2.35044344e+00 2.43079780e+00 1.82863555 0.94449518 947.75 -6.56337908e-01 2.38879802e+00 2.47732425e+00 1.83893619 0.95280689 948.00 -7.59663882e-01 2.40966562e+00 2.52657429e+00 1.87619091 0.94207712 948.25 -9.49690318e-01 2.34701000e+00 2.53187038e+00 1.95529490 0.95174333 948.50 -1.01019793e+00 2.39373837e+00 2.59816921e+00 1.97013751 0.94905902 948.75 -1.14631434e+00 2.49663276e+00 2.74721891e+00 2.00122846 0.95004586 949.00 -1.17354932e+00 2.64714773e+00 2.89561895e+00 1.98808628 0.95235991 949.25 -1.24476992e+00 2.75290908e+00 3.02125149e+00 1.99544944 0.96260840 949.50 -1.37664122e+00 2.88296302e+00 3.19477962e+00 2.01628991 0.95957444 949.75 -1.50736048e+00 3.04249939e+00 3.39542901e+00 2.03078522 0.95475369 950.00 -1.54960934e+00 3.12801713e+00 3.49081370e+00 2.03075451 0.91227237 950.25 -1.53083268e+00 3.23193632e+00 3.57615171e+00 2.01314919 0.90843218 950.50 -1.73081057e+00 3.36648367e+00 3.78535567e+00 2.04568401 0.93080820 950.75 -1.82160531e+00 3.37718224e+00 3.83713510e+00 2.06545420 0.93568945 951.00 -1.91642034e+00 3.54960543e+00 4.03390204e+00 2.06584963 0.90830864 951.25 -2.10011621e+00 3.79672129e+00 4.33884555e+00 2.07604664 0.90749304 951.50 -2.39315978e+00 4.42889535e+00 5.03411638e+00 2.06620161 0.91161243 951.75 -2.32828866e+00 4.49035169e+00 5.05808130e+00 2.04914141 0.91208990 952.00 -2.42915733e+00 4.62726729e+00 5.22612743e+00 2.05421656 0.90547804 952.25 -2.28176819e+00 4.70206239e+00 5.22645738e+00 2.02259037 0.91626404 952.50 -2.02009957e+00 4.68301204e+00 5.10013765e+00 1.97804799 0.87624427 952.75 -2.40722721e+00 4.94405044e+00 5.49894332e+00 2.02390406 0.87333747 953.00 -3.11685449e+00 4.62087660e+00 5.57380323e+00 2.16421331 0.88499380 953.25 -3.24875352e+00 4.37415287e+00 5.44863403e+00 2.20961938 0.86314370 953.50 -4.05546269e+00 4.35762975e+00 5.95279049e+00 2.32029363 0.88541773 953.75 -4.44503600e+00 4.42027188e+00 6.26874378e+00 2.35898786 0.88263332 954.00 -5.88459624e+00 5.02980890e+00 7.74128222e+00 2.43435231 0.81858804 954.25 -7.02808804e+00 5.31527305e+00 8.81170523e+00 2.49407805 0.84771663 954.50 -8.84084308e+00 4.53105921e+00 9.93433460e+00 2.66798374 0.75610622 954.75 -9.65725329e+00 4.50222188e+00 1.06551651e+01 2.70534789 0.67448112 955.00 -9.89887466e+00 2.52853190e+00 1.02167115e+01 2.89150406 0.46277899 955.25 -9.59818037e+00 4.02152275e+00 1.04066186e+01 2.74482519 0.40544207 955.50 -9.46845996e+00 1.99677772e+00 9.67671717e+00 2.93375081 0.21857547 955.75 -9.01172834e+00 -6.19271938e-01 9.03298098e+00 -3.07298207 0.21965932 956.00 -4.92416831e+00 -1.19286423e+00 5.06659241e+00 -2.90392428 0.10752981 956.25 -2.09161734e+00 -3.30020109e+00 3.90719725e+00 -2.13568789 0.06851845 956.50 1.26705636e+00 -4.79347745e+00 4.95811031e+00 -1.31237743 0.10486774 956.75 3.58919001e+00 -4.80578988e+00 5.99815816e+00 -0.92931616 0.20680501 957.00 2.33630006e+00 -4.87536706e+00 5.40624657e+00 -1.12392272 0.24037110 957.25 1.85856558e+00 -4.63950306e+00 4.99792503e+00 -1.18977641 0.26330426 957.50 2.61671200e+00 -6.01996412e+00 6.56408026e+00 -1.16076171 0.51383397 957.75 2.92937538e+00 -4.88972822e+00 5.70005984e+00 -1.03104800 0.48703460 958.00 1.56284455e+00 -3.89149256e+00 4.19359004e+00 -1.18890672 0.40942946 958.25 5.53551714e-01 -3.34555107e+00 3.39103693e+00 -1.40682285 0.29171833 958.50 -2.71113297e-01 -2.86259672e+00 2.87540648e+00 -1.66522354 0.24329418 958.75 -5.45083416e-01 -2.69664127e+00 2.75117976e+00 -1.77024315 0.31183970 959.00 -1.29060060e+00 -2.34478646e+00 2.67650396e+00 -2.07395645 0.37555793 959.25 -1.54611262e+00 -1.50983122e+00 2.16103090e+00 -2.36806633 0.35102298 959.50 -1.91657976e+00 -9.49522790e-01 2.13889493e+00 -2.68161121 0.45551974 959.75 -1.68630345e+00 1.70120022e-01 1.69486287e+00 3.04104943 0.28890392 960.00 -1.13300535e+00 1.20030707e+00 1.65058722e+00 2.32735863 0.36269267 960.25 -8.96228138e-01 1.74829231e+00 1.96462487e+00 2.04449728 0.42069702 960.50 -8.33886050e-01 2.26459975e+00 2.41325050e+00 1.92361556 0.45912597 960.75 -2.30119021e-02 2.80877130e+00 2.80886557e+00 1.57898901 0.57007124 961.00 3.67276342e-01 3.08548245e+00 3.10726469e+00 1.45232011 0.60360657 961.25 6.60099871e-01 3.75682726e+00 3.81437844e+00 1.39686500 0.71443467 961.50 1.00373684e+00 3.84600609e+00 3.97482711e+00 1.31550904 0.72712821 961.75 1.75652392e+00 4.30959927e+00 4.65381802e+00 1.18376912 0.72465544 962.00 2.29968612e+00 4.21692837e+00 4.80323236e+00 1.07153306 0.70978286 962.25 2.86381051e+00 3.71856047e+00 4.69351708e+00 0.91453000 0.70519368 962.50 3.22047564e+00 3.50934570e+00 4.76308414e+00 0.82829571 0.74599778 962.75 3.94809253e+00 3.50709914e+00 5.28083127e+00 0.72631449 0.83553195 963.00 4.14327653e+00 3.43528259e+00 5.38218421e+00 0.69224787 0.85112806 963.25 4.30317112e+00 3.03690357e+00 5.26688380e+00 0.61456539 0.83879133 963.50 4.45871681e+00 2.95409534e+00 5.34853577e+00 0.58514290 0.85839010 963.75 4.04657718e+00 2.50079713e+00 4.75697101e+00 0.55355199 0.82681423 964.00 4.20835325e+00 2.17772130e+00 4.73842877e+00 0.47753037 0.87185212 964.25 4.30495516e+00 1.88664372e+00 4.70021951e+00 0.41303922 0.86820884 964.50 4.19888184e+00 1.77462728e+00 4.55849873e+00 0.39987240 0.82599321 964.75 4.09084323e+00 1.34108749e+00 4.30505680e+00 0.31678639 0.79845980 965.00 3.94701568e+00 1.44505230e+00 4.20322601e+00 0.35095633 0.76161715 965.25 3.71750073e+00 1.16708256e+00 3.89639492e+00 0.30419876 0.72990914 965.50 3.47931686e+00 1.27770028e+00 3.70650291e+00 0.35193893 0.75544131 965.75 2.94519628e+00 1.45561819e+00 3.28527098e+00 0.45902474 0.70604408 966.00 2.92112047e+00 1.21211488e+00 3.16262032e+00 0.39332632 0.67384917 966.25 2.66168737e+00 1.39462737e+00 3.00492349e+00 0.48263421 0.64172843 966.50 2.26786643e+00 1.45484962e+00 2.69440264e+00 0.57038075 0.64463104 966.75 2.57527465e+00 1.28254898e+00 2.87697261e+00 0.46206568 0.68877427 967.00 2.45925275e+00 1.05035280e+00 2.67416624e+00 0.40365007 0.72472936 967.25 2.41633820e+00 9.47490183e-01 2.59546295e+00 0.37369331 0.70642575 967.50 2.14578179e+00 1.24536683e+00 2.48099134e+00 0.52586739 0.65675566 967.75 2.08497446e+00 1.49097724e+00 2.56322680e+00 0.62079228 0.73855783 968.00 1.93183724e+00 1.50305252e+00 2.44768503e+00 0.66120843 0.75806749 968.25 1.91707789e+00 1.51488727e+00 2.44337289e+00 0.66874066 0.82246726 968.50 1.86701280e+00 1.77374043e+00 2.57524598e+00 0.75978479 0.78116300 968.75 1.65029470e+00 1.95346270e+00 2.55724248e+00 0.86932608 0.75628670 969.00 1.78904194e+00 1.90378326e+00 2.61248191e+00 0.81645959 0.74319902 969.25 1.88185224e+00 1.97804635e+00 2.73020791e+00 0.81031442 0.76738340 969.50 2.02408692e+00 1.84720634e+00 2.74027355e+00 0.73973961 0.79101516 969.75 2.03643464e+00 1.65479670e+00 2.62400803e+00 0.68237380 0.72428408 970.00 1.89801087e+00 1.57558745e+00 2.46676328e+00 0.69284221 0.68337619 970.25 1.87937030e+00 1.55052155e+00 2.43642152e+00 0.68981304 0.76181121 970.50 1.80599838e+00 1.65845815e+00 2.45196117e+00 0.74283705 0.73159370 970.75 1.43329530e+00 1.96128028e+00 2.42918829e+00 0.93969965 0.73149682 971.00 1.69391639e+00 2.11357700e+00 2.70860859e+00 0.89517472 0.77917532 971.25 1.65725091e+00 1.99086038e+00 2.59036786e+00 0.87659170 0.79816849 971.50 1.47849268e+00 1.62001047e+00 2.19325660e+00 0.83103940 0.77125771 971.75 1.38197388e+00 1.57546767e+00 2.09569802e+00 0.85073112 0.75461532 972.00 1.31054867e+00 1.67519094e+00 2.12692325e+00 0.90692431 0.73511664 972.25 1.40042233e+00 1.59890146e+00 2.12548079e+00 0.85147645 0.77690438 972.50 1.31441691e+00 1.57379551e+00 2.05049363e+00 0.87496382 0.77619313 972.75 1.29302721e+00 1.58300290e+00 2.04397103e+00 0.88588356 0.80582775 973.00 1.35391895e+00 1.88373947e+00 2.31982131e+00 0.94760358 0.87680408 973.25 1.16185310e+00 1.95384816e+00 2.27319714e+00 1.03432096 0.89825372 973.50 1.13087167e+00 2.11688622e+00 2.40001625e+00 1.08015309 0.91007622 973.75 1.06081905e+00 2.23123653e+00 2.47057757e+00 1.12698907 0.90004515 974.00 9.86129861e-01 2.39407383e+00 2.58921641e+00 1.18006973 0.90283990 974.25 1.07364023e+00 2.49878536e+00 2.71967491e+00 1.16498115 0.89133189 974.50 1.04956750e+00 2.59219961e+00 2.79662131e+00 1.18607764 0.88109355 974.75 9.91869330e-01 2.72460011e+00 2.89952592e+00 1.22166696 0.86577625 975.00 1.25916011e+00 2.86038172e+00 3.12526283e+00 1.15611603 0.85686906 975.25 1.35070588e+00 2.79479724e+00 3.10407764e+00 1.12060345 0.83520460 975.50 1.62814299e+00 3.04493829e+00 3.45289716e+00 1.07977189 0.83344617 975.75 1.56668529e+00 2.92899295e+00 3.32167164e+00 1.07962884 0.77143041 976.00 1.68315633e+00 2.42723820e+00 2.95372655e+00 0.96448321 0.66089608 976.25 2.07489427e+00 2.24910596e+00 3.06001044e+00 0.82566586 0.61505123 976.50 2.28353159e+00 2.66291705e+00 3.50794009e+00 0.86194685 0.67857149 976.75 2.36170017e+00 2.82620478e+00 3.68307767e+00 0.87469611 0.65910641 977.00 2.21682690e+00 2.70048733e+00 3.49384506e+00 0.88344146 0.63541314 977.25 2.25662465e+00 2.39739315e+00 3.29239256e+00 0.81563561 0.63004332 977.50 2.35158949e+00 2.68477618e+00 3.56903296e+00 0.85145808 0.60031041 977.75 1.84160912e+00 3.04146301e+00 3.55556204e+00 1.02634173 0.49259072 978.00 1.63757686e+00 2.95969014e+00 3.38251736e+00 1.06542815 0.34478794 978.25 2.23439844e+00 2.84098793e+00 3.61438083e+00 0.90434986 0.35135580 978.50 2.44728741e+00 2.83984691e+00 3.74885931e+00 0.85951024 0.43558044 978.75 1.97089168e+00 2.72099053e+00 3.35979217e+00 0.94392826 0.39534166 979.00 1.61322637e+00 2.27429645e+00 2.78835501e+00 0.95383612 0.30062853 979.25 9.91480919e-01 2.77446990e+00 2.94630577e+00 1.22758099 0.31366241 979.50 3.94878081e-01 2.75471641e+00 2.78287463e+00 1.42842005 0.28170369 979.75 -9.40610730e-02 2.16160737e+00 2.16365291e+00 1.61428330 0.21834177 980.00 -3.99679819e-03 2.15500842e+00 2.15501212e+00 1.57265098 0.25410076 980.25 5.13180949e-02 2.15709623e+00 2.15770658e+00 1.54701045 0.29749594 980.50 -2.06733273e-01 2.44573177e+00 2.45445362e+00 1.65512405 0.37101332 980.75 -8.79745219e-01 2.27714145e+00 2.44117284e+00 1.93946952 0.37729747 981.00 -1.61867609e+00 1.90662948e+00 2.50106942e+00 2.27469360 0.41852175 981.25 -9.36259551e-01 1.81078410e+00 2.03850951e+00 2.04798794 0.44901448 981.50 -8.54624176e-01 1.80234987e+00 1.99470487e+00 2.01356902 0.51471800 981.75 -9.96436728e-01 1.69832783e+00 1.96906159e+00 2.10139119 0.45340854 982.00 -7.64708731e-01 1.68445312e+00 1.84990858e+00 1.99695544 0.46564474 982.25 -8.41140063e-01 1.52327670e+00 1.74008291e+00 2.07532032 0.39948694 982.50 -8.35945337e-01 1.48670366e+00 1.70560617e+00 2.08301947 0.47152119 982.75 -5.04660324e-01 1.11352658e+00 1.22254795e+00 1.99631569 0.29088058 983.00 -2.91352018e-01 1.06071355e+00 1.09999965e+00 1.83886082 0.23208695 983.25 -4.43794571e-01 1.06441584e+00 1.15322795e+00 1.96581795 0.20508658 983.50 -1.91181546e-01 1.21151990e+00 1.22651166e+00 1.72730875 0.22411073 983.75 -3.74343800e-01 1.04328177e+00 1.10840883e+00 1.91530132 0.22880182 984.00 -3.77268956e-01 8.62626416e-01 9.41518029e-01 1.98308017 0.23373351 984.25 -5.74241203e-02 7.69331695e-01 7.71471831e-01 1.64529973 0.16909750 984.50 -2.84799225e-01 8.54517551e-01 9.00727952e-01 1.89250479 0.22695918 984.75 -9.31761434e-01 1.00142757e+00 1.36785838e+00 2.32017318 0.38075069 985.00 -7.82791573e-01 9.28910588e-01 1.21475822e+00 2.27103620 0.27398730 985.25 -9.36401615e-01 1.35075550e+00 1.64359010e+00 2.17697289 0.36640686 985.50 -9.93771164e-01 1.49938576e+00 1.79881594e+00 2.15610716 0.47108204 985.75 -9.14544418e-01 1.44883631e+00 1.71333539e+00 2.13386087 0.41582509 986.00 -1.22335355e+00 1.56651026e+00 1.98759863e+00 2.23380799 0.40982237 986.25 -1.46866004e+00 1.60780260e+00 2.17761142e+00 2.31099719 0.42950304 986.50 -1.30521736e+00 1.98233167e+00 2.37344290e+00 2.15307166 0.41018563 986.75 -1.24424132e+00 2.50896235e+00 2.80054075e+00 2.03117356 0.51618692 987.00 -1.31630749e+00 2.42441364e+00 2.75870384e+00 2.06820187 0.48238103 987.25 -1.14355560e+00 2.48542828e+00 2.73588617e+00 2.00202094 0.56753204 987.50 -1.06617992e+00 2.73418033e+00 2.93470300e+00 1.94260465 0.60997269 987.75 -8.78646491e-01 2.71942262e+00 2.85784518e+00 1.88330913 0.55639396 988.00 -1.04608102e+00 3.09342074e+00 3.26550722e+00 1.89688743 0.65985824 988.25 -1.04139866e+00 2.85256640e+00 3.03671635e+00 1.92083674 0.67524550 988.50 -7.14256334e-01 2.10442937e+00 2.22233775e+00 1.89800245 0.54602670 988.75 -9.05773474e-01 1.97874204e+00 2.17619982e+00 2.00007823 0.58259348 989.00 -8.93700905e-01 1.98652719e+00 2.17830016e+00 1.99355131 0.51562133 989.25 -7.26013845e-01 2.19703392e+00 2.31388292e+00 1.88995128 0.50885002 989.50 -8.09198889e-01 1.99692711e+00 2.15465095e+00 1.95579635 0.53425205 989.75 -7.99156732e-01 1.84410177e+00 2.00981661e+00 1.97972514 0.49690296 990.00 -5.04567533e-01 1.70034001e+00 1.77362469e+00 1.85926429 0.46569633 990.25 5.08312422e-02 1.66220867e+00 1.66298571e+00 1.54022531 0.47481464 990.50 -9.80122599e-02 1.21641239e+00 1.22035466e+00 1.65119749 0.34403318 990.75 -3.31003987e-01 8.11070943e-01 8.76013535e-01 1.95827217 0.23890089 991.00 -3.73374732e-01 5.07540937e-01 6.30084512e-01 2.20505287 0.15919479 991.25 -4.91683799e-01 1.85302813e-01 5.25442757e-01 2.78118009 0.10936007 991.50 -5.39341099e-01 -3.29547138e-02 5.40346957e-01 -3.08056672 0.10546875 991.75 -7.36738914e-01 -6.38068552e-02 7.39496817e-01 -3.05520108 0.20936533 992.00 -8.62565829e-01 -2.59158540e-01 9.00656959e-01 -2.84972239 0.33831707 992.25 -8.76136165e-01 -3.87858564e-01 9.58148655e-01 -2.72483257 0.39352777 992.50 -9.20853618e-01 -5.15273803e-01 1.05521490e+00 -2.63143856 0.47532238 992.75 -8.51514146e-01 -3.40162172e-01 9.16944188e-01 -2.76153534 0.41682290 993.00 -1.15928777e+00 -1.92105790e-01 1.17509691e+00 -2.97737475 0.56606913 993.25 -1.25932363e+00 -2.67110705e-01 1.28733995e+00 -2.93258381 0.57277110 993.50 -1.16049922e+00 -4.77883940e-01 1.25504243e+00 -2.75096253 0.56786532 993.75 -1.17045499e+00 -6.87978937e-01 1.35767444e+00 -2.61020125 0.71278490 994.00 -1.51517527e+00 -8.38458285e-01 1.73169524e+00 -2.63616289 0.69983786 994.25 -1.56203302e+00 -8.87348768e-01 1.79647850e+00 -2.62497979 0.67336432 994.50 -1.40630492e+00 -9.53528695e-01 1.69909108e+00 -2.54575860 0.63700219 994.75 -1.41715294e+00 -8.87035690e-01 1.67187164e+00 -2.58232630 0.60537436 995.00 -1.25690891e+00 -7.40536903e-01 1.45884026e+00 -2.60917216 0.50538162 995.25 -1.08387732e+00 -5.87679143e-01 1.23294640e+00 -2.64475703 0.31037827 995.50 -7.15984764e-01 -1.03160452e+00 1.25572372e+00 -2.17751760 0.22037703 995.75 -5.04701661e-01 -1.11385729e+00 1.22286624e+00 -1.99623485 0.20151287 996.00 -6.08064431e-01 -1.00511959e+00 1.17473731e+00 -2.11486021 0.17990561 996.25 -5.23112988e-01 -1.02566465e+00 1.15136231e+00 -2.04243048 0.14968749 996.50 -7.18730509e-01 4.24510969e-01 8.34735351e-01 2.60808395 0.04069032 996.75 -1.15158319e+00 5.94275868e-01 1.29588104e+00 2.66518671 0.10504012 997.00 -2.14746687e+00 6.05446262e-01 2.23118335e+00 2.86679045 0.26862567 997.25 -2.38889397e+00 1.15718324e+00 2.65440906e+00 2.69050173 0.35263929 997.50 -3.35066781e+00 1.89360231e+00 3.84872764e+00 2.62719866 0.72987054 997.75 -3.21822968e+00 1.74329488e+00 3.66006548e+00 2.64514897 0.74826176 998.00 -3.05498603e+00 1.64862348e+00 3.47144049e+00 2.64673034 0.75096576 998.25 -2.88091966e+00 1.57858245e+00 3.28506022e+00 2.64032937 0.75556694 998.50 -2.61091906e+00 1.63164067e+00 3.07882276e+00 2.58304395 0.79348034 998.75 -2.67733174e+00 1.51427610e+00 3.07589619e+00 2.62685785 0.73913519 999.00 -3.04346201e+00 1.37016698e+00 3.33766664e+00 2.71857232 0.65474289 999.25 -2.66994189e+00 6.54990121e-01 2.74910927e+00 2.90102353 0.61508684 999.50 -2.57689740e+00 4.23834274e-01 2.61151981e+00 2.97857751 0.64017612 999.75 -2.45084862e+00 -8.78533133e-02 2.45242271e+00 -3.10576192 0.58406750 1000.00 -2.10490771e+00 0.00000000e+00 2.10490771e+00 3.14159265 0.47050057